of Aurora SINGLE FAMILY MASTER PLAN REVIEW Plan Submittal Checklist • 2013 Permit Center • 15151 E. Alameda Parkway, Ste 2400 • Aurora, CO 80012 • 303.739.7420 Fax: 303.739.7551 • Email: [email protected]

PROJECT ADDRESS

PROJECT TITLE

CONTACT PERSON PHONE EMAIL

INTAKE STAFF PERSON DATE

COMMENTS

The following checklist contains the minimum standard information required for a master single family residential project submitted for review for the purpose of obtaining permits. The scope of the building plan review is the examination of building documents for compliance with the requirements of the adopted codes and all corresponding amendments of the City of Aurora.

THERE MAY BE ADDITIONAL PERMIT REQUIREMENTS THAN THOSE PRESENTED ON THIS CHECKLIST. PLEASE VERIFY WITH AURORA WATER; , RECREATION AND OPEN SPACE; AND PUBLIC WORK’S FOR ANY ADDITIONAL REQUIREMENTS/PERMITS.

AURORA WATER PERMITS: Glenna Owens, Water Plans Technician, 303.739.7393 Diana Porter, Administrative Technician, 303.739.7395

PUBLIC WORKS – PUBLIC IMPROVEMENTS PERMITS: Terry von Clausburg, Public Improvements Inspector Supervisor, 303.739.7861

PARKS, RECREATION AND OPEN SPACE PERMITS: Christopher Ricciardiello, Plans Review Coordinator, 303.739.7154

Prior to acceptance of building plans for formal review, building plan review staff will screen the plans for general completeness and for compliance with the plan submittal checklist requirements. Information required for each checklist item shall be clearly documented on the plans as applicable to the project to accurately describe the scope of the proposed construction. Submitted plans cannot be accepted for review until all required information contained in the checklist is clearly shown on the plans.

Single Family Master Plan Review (Revised 05/2016) CONSIDERATIONS FOR PLAN SUBMITTAL

Pre-Submittal Meetings or Staff Consultations are available upon request to discuss or resolve any code issues related to the plan review.

¨ Plans received by mail, courier, UPS or otherwise unaccompanied by a knowledgeable applicant will be checked for completeness per this checklist. If plans are determined to be unacceptable for plan review, the applicant (listed contact person) will be notified of the missing information. This information must then be provided or the plans picked up within two weeks, or they will be discarded.

¨ Separate approvals are required for each where the Master Plan will be constructed. Approval for a Master Plan in a subdivision does not constitute approval for construction at all subdivisions within the City of Aurora.

¨ A Plot Plan is not required to be submitted for Master Plan submittals. ¨ Plan review fees must be paid in full before plans will be accepted for plan review. ¨ NOTE: Single Family plans are only reviewed for compliance with structural provisions of the IRC. Mechanical, and Electrical elements are inspected for compliance in the field during construction.

THE CITY OF AURORA HAS ADOPTED THE FOLLOWING CODES* • 2015 International (IBC) • 2015 International Energy Conservation Code • 2015 International Mechanical Code (IMC) (IECC) • *Amendments to the codes can be found at • 2015 International Plumbing Code (IPC) www.municode.com • 2015 International Code (IFC) • (Chapter 22 and Building • 2014 National Electrical Code (NEC) Regulations)

MINIMUM PLAN REVIEW DOCUMENT REQUIREMENTS

GENERAL INFORMATION ¨ Each sheet shall be sealed and PLANS signed by a Colorado licensed/ ¨ The “City of Aurora Building ¨ Provide a complete and clearly Permit” application from must be registered professional designer dimensioned floor layout at each completed in its entirety. level which identifies the use as required by state law. (Consult for each and the type and ¨ An individual plan review with building plan review staff location of each . submittal package is required for ¨ Notes:______each master. for projects which require ¨ Indicate the model on each sheet professional and EXTERIOR ELVATIONS of plans. registered ). ¨ Provide standard elevations and ¨ Plans should be submitted in all optional elevations including ¨ Indicate on the cover sheet of Adobe PDF format for electronic finish materials, slope, grade review and the approved plans will plans the name, title, address, lines, masonry calculations, etc. be returned in PDF format. Other and phone number of designer(s)- ¨ Notes:______formats will not be accepted. Plans of record and a complete index of with electronic stamps WALL SECTIONS are acceptable. The applicant is all submitted plans. ¨ Show details of construction: responsible to provide a printed ¨ Each sheet of plans shall be a materials to be used, insulation to set of plans for use in the field. be installed, and finishes. minimum size of 24” x 36” drawn ¨ Approved paper plans will not ¨ Provide a detail of stair be returned but will be available to scale in U.S. units to ensure construction, including member for download at www.auroragov. legibility with sufficient detail to sizes, rise and run dimensions, org under property information. headroom clearance, guardrail For questions contact Customer clearly document the nature and and handrail details. Service at 303.739.7420. scope of proposed construction. ¨ Notes:______FOUNDATION PLANS AND ROOF PLANS HEATING AND COOLING DETAILS SYSTEM CALCULATIONS ¨ Dimensions. ¨ plans are not required ¨ Heating and cooling equipment for master plan submittals. The lot ¨ Rafter sizes and spacing. shall be sized in accordance with specific soils report and foundation ACCA Manual S based on building plans shall be submitted when ¨ Roof diaphragm information. loads calculated in accordance applying for the lot specific permit. with ACCA Manual J or other ¨ Beam sizes. approved heating and cooling ELECTRICAL, PLUMBING, ¨ Bearing and posts. calculation methodologies – IRC M1401.3. Provide supporting MECHANICAL ¨ Roof ventilation. documentation. Provide a duct ¨ NOTE: Plans are not required to design in accordance with ACCA be submitted, these items will be ¨ Roofing materials. Manual D or other approved field inspected. ¨ NOTE: “ Built Truss Plans” method – IRC M1601.1. ¨ Notes:______FRAMING PLAN AND can be submitted at time of plan DETAILS review or at the time of inspection. AIRCRAFT NOISE ¨ Dimensions. ¨ Notes:______REDUCTION – LDN ¨ Joist sizes and spacing. (PER ARTICLE XI OF THE CITY ¨ Beam, , and header sizes OF AURORA CODE) and locations. ENERGY CONSERVATION ¨ Plans for to be located ¨ Type of (i.e. Hem Fir # 2). PLANS within a specified aircraft noise ¨ Framing for exterior decks and zone shall show compliance with . ¨ Provide documentation showing one of three methods outlined in ¨ Foundation ventilation. Article XI (Prescriptive, Design ¨ Posting size (i.e. (3) “2x6”) for all compliance with the prescriptive by Analysis or Field Testing). beams, girder trusses, etc. requirements of the IRC Table A copy of the current Updated ¨ Indicate all braced wall lines Noise Ordinance is available upon on the plans and demonstrate N1102.1.2, the Total UA Alterna- request. Plans and specifications compliance with IRC R602.10. tive in the 2009 IRC N1102.1.4 or shall show in sufficient detail any Where the bracing requirements pertinent data and features of the of section R602.10 cannot be the Simulated Performance Alter- building and the sound insulation met, provide an engineered lateral design complying with IBC native from the 2009 IECC section techniques to clearly indicate compliance with the requirements 2308.1.1. Submit calculation for 405. all engineered systems. of this article. ¨ Notes:______¨ Notes:______¨ Notes:______

SINGLE FAMILY VALUATION WORKSHEET

APPROVED FOR SUBDIVISION DATE

BUILDER MODEL

STANDARD MODEL Description Total Square Feet Sq. Ft. Cost Total Valuation

NOTE: Enter whole numbers for $105.00 square footage

Note: Effective November 7, 2011 our division changed the calculation process for all single family plan review fees and permit fees. Essentially, we will only utilize the FINISHED SQUARE FOOTAGE of the as the primary means of calculating fees. The dollar amount to be utilized for all single family is now $105 per square foot. PLAN REVIEW TIMES

The City of Aurora Building Division is committed to overall maximum average times for plan reviews. Those plans requiring corrections will be rejected within the time frame listed below and, when resubmitted with all corrections done properly, will receive a plan approval within the time frame listed below following receipt of the complete and error free corrections.

NOTICE: The reviews of Single-Family plans are conducted independently by both the Planning Department and the Building Division. When plans are accepted in for review by the Building Division they are immediately routed to the Planning Department for review of the elevation plans. Once approved by the Planning Department, the Building Division plan review process starts. Single-Family reviews are NOT routed to other internal city departments (e.g. , Aurora Water, Planning Department, etc.) for approval prior to permit release.

PLANNING DEPARTMENT REVIEW Planning Elevation Review = 7 working days. Code corrections by applicant = 7 working days. City review of code corrections = 2 working days.

TOTAL WORKING DAYS = 16 DAYS

BUILDING DIVISION REVIEW City plan review for code compliance = 21 working days. Code corrections by applicant = 7 working days. City review of code corrections = 2 working days.

TOTAL WORKING DAYS = 30 DAYS

BOARD OF APPEALS: The City of Aurora has created a Building Code and Contractors Appeals and Standards Board. Applicants have the right to have the board hear appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of the building code. Any application for appeal to the board shall be based on a claim that the true intent of the code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of the building cod do not fully apply or an equally good or better form of construction is proposed.

COMMENTS OR CONCERNS: We are always looking for ways to improve the website and our hand-outs for the Building Division. Please email [email protected] with your comments and suggestions.

“Colorado’s Only IAS Accredited Building Division” City of Aurora Planning & Development Services Department SINGLE-FAMILY DETACHED, TWO-FAMILY, AND SINGLE-FAMILY Attached Homes Development Checklist 15151 E. Alameda Parkway, Ste 2300 • Aurora, CO 80012 • 303-739-7250

To be attached as part of the application or included on the disk in conjunction with Building Department’s City of Aurora Single Family Master Plan Review – Plan Submittal Check List and Worksheet - 2013

Complete the following: Project Name

Builder/ Address

Date Reviewed by

Subdivision Building Dept. RSN #

Address or General Location

Zoning District Builder\Architect

Contact Phone

Fax Email

Exterior Elevation Review Checklist for Paper and Digital Submittals. To be checked at the Building Department. Incorrect or incomplete submittals will be rejected.

24” X 36” sheet size, show the following on the plans: (See Summary of Sec. 146-1302 Design Standards) £ Standard, optional, and required enhanced (distinct) elevations, Sec. 146-1302(E)(G) £ Roof Slope, Materials and Guarantee, pg 8, Roofs £ Grade Plane, pg 14, Ordinance No. 2012-26 £ Masonry Calculations, pg 3, Sample Table £ Coverage (%), Sec. 146-1302(C) £ Durable Materials List, Sec. 146-1302(F), pg 9 £ Architectural Features Credits, Table 13.1, pg 7 £ Conservation and Credits, Table 13.2, pg 6; Chk’d by: ______.

Single-Family Detached, Two-Family and Single-Family (Revised 2/2014) 1 PRE-QUALIFICATION APPLICATION INSTRUCTIONS

Each application submitted for approval shall be evaluated on its own merits. Models and Elevations approved for other subdivisions/developments must be re-submitted. 1. Special Features – Architectural, Conservation, and indoor air quality features are implemented with a weighted point system. Each will be assigned points. All residential design shall: • Meet a minimum score of 17 points from Table 13.1 Architectural Features; and • Meet a minimum score of 8 points from Table 13.2 Conservation and Indoor Air Quality Features. • Document the conservation points listed.

Place the totals from the other pages here. SUMMARY OF TOTAL POINTS: ARCHITECTURAL FEATURES POINT TOTAL ______CONSERVATION FEATURES POINT TOTAL ______

TOTAL POINTS ACHIEVED ______

SUMMARY

This request is for an architectural review for ______single family detached home models with______elevations located in______Subdivision Filing No.______

1. Show the total number of lots in the subdivision______.

2. List each model and their corresponding elevations:______

3. Acknowledge compliance with Aurora City Code, Chapter 146, Building and Code, Sections 146-1301, 146-1302, and 146- 2001. _____ Yes; Initial_____.

4. Show general description of homes, e.g. one and two story, attached one, two, and three car garages, etc.______

5. List current and applicable FDP/GDP documents with architectural design requirements and masonry standards.______

2 SUMMARY OF SEC. 146-1302 DESIGN STANDARDS

Show items in bold on the plans.

The following is a summary of the required elements from Sec. 146-1302 Design Standards for Single-Family Detached, Two-Family, and Single-Family Attached Duplex Homes.

• Roofing Materials. Show approved roofing materials and warranty. (at least 25 years) • Side-specific-Enhanced Design. Show side-specific enhanced design elevations on the plans. Homes with side and/or elevations adjacent to , parks, golf courses, or open space shall distribute architectural features and materials so as to achieve side-specific-design for those elevations.

• Recessed and Alternate Load Garages. At least 50% of the total number of lots in a subdivision must have recessed garages, alternate-load garages or any combination of either.

• Masonry Requirement. Show masonry requirements on the plans. See sample masonry calculations below: An average of not less that 15% of the net of all residential design plans within a subdivision plan shall consist of masonry. Show the percentages of masonry provided per each elevation and include an up-dated spreadsheet showing that you are in compliance with the 15% requirement. The following should be placed on elevation sheets on the building master plan.

Sample Masonry Calculations for Single Family Development: Front Elevation: 25% Left Side At-grade Elevation 15% Right Side At-grade Elevation 10% Rear At-grade Elevation 10% Total Façade (At-grade ) 15% Front Elevation: 25% Left Side Garden Level Elevation 0% Right Side Garden Level Elevation 10% Rear Side Garden Level Elevation 15% Total Façade (Garden Level Basement) 15% Front Elevation: 35% Left Side Walkout Elevation 10% Right Side Walkout Elevation 10% Rear Side Walkout Elevation 25% Total Façade (Walkout Basement) 20%

• Garages. Every single-family detached, two-family and single-family attached duplex for which a building permit is issued after November 1, 2012, shall include a garage large enough to fully enclose at least one off- space per dwelling on the same lot as the residential structure..

• Garage Door Coverage. Show garage coverage percentage for each elevation. The garage door or shall not cover more than 47% for a two car garage or 55% for a three car garage of the total width of the front elevation.

• Garage Door . The garage shall include at least four square feet of area, including any window areas located within overhead or swinging doors. Such window areas shall admit light, but may be either transparent or translucent.

• Adjacent Setbacks. For homes on adjacent lots a front stager shall vary by a minimum of 2 feet. stagers are MEASURED FROM THE LONGEST FOUNDATION WALL IN THE FRONT PLANE OF THE HOME TO THE FRONT PROPERTY LINE. e.g. If a home has a front yard setback of 22 feet adjacent homes must have setbacks of 20 feet or 24 feet minimum. See item #8 Alternative Design below. Show setback/s on plot plans submitted with building permit.

• Durable Materials. Show a list of durable materials provided per each elevation. A minimum 25 year written manufactured limited warranty on durable siding material is required.

• Alternative Design. No model elevation shall be repeated more than once every four lots. No identical model home elevation shall be repeated directly across the street.

3 • Repetitive Design - Distinct Elevations. In order to be considered a distinct elevation, an elevation shall incorporate at least four of the following items on the front façade elevation: • Windows and doors to include at least a two-foot vertical or horizontal variation in size or location • Use of different materials • 2 foot difference in width • Front locations and proportions must differ substantially • Front plane variations • Roof dormers • Window shapes that are substantially different • Variation in building types: such as Ranch and Two-story

• Roof Variation. 30% of the model/elevation combinations must have variation in the roof line. • Conservation and Indoor Air Quality Credits – 8 points min. from Table 13.1. List conservation and indoor air quality credits for each model.

• Architectural Features Credits – 17 points min. from Table 13.2. List architectural features credits for each model/ elevation.

• Transferring Credits. Conservation and Indoor Air Quality Features points may be credited to architectural feature point total using the chart found in Sec 1302(J). Show a table for each elevation seeking a credit. Show the number of air quality features points provided and the number of points credited to architectural features.

• Windows. There shall be no windowless elevations.

Conservation and indoor air quality feature points may be credited to architectural feature point totals using the following chart:

TOTAL NUMBER OF POINTS THAT MAY BE CONSERVATION AND/OR TRANSFERRED TO INDOOR AIR QUALITY FEATURE ARCHITECTURAL FEATURE POINT POINTS EARNED TOTAL 8-10 0 11 +1 12 +2 13 +3 14 +4 15 +5 16+ +5

4 TABLE 13.1. ARCHITECTURAL FEATURES

WINDOWS 3 2 1 TOTAL 1. Window mullion patterns on 75% of windows x 2. One full height, two-story bay window (for a one-story residential design plan, one full x height bay window) 3. One bay window x 4. One or more roof window dormers x 5. Two or more clerestory windows or windows with transoms above the main window x 6. Front door with one or more sidelights, transom window or double door x 7. Ribbon windows with two or more horizontal rows of windows containing at least three x windows each. 8. Decorative shutters on at least two street facing windows x 9. At least two special, decorative window heads or window sills on street facing x elevations 10. Four or more square feet of windows in the garage that are not on the door x 11. Garage door(s) with windows x ROOFS 3 2 1 TOTAL 12. Dimensional roof shingles with a 30-year warranty (previously no specified warranty x length) 13. Clay, or tile, cement, or standing seam metal roof x 14. Decorative roofing elements (e.G., Copper above a bay window) x 15. 16-Inch roof on all sides x ARCHITECTURAL DETAILS/STYLES 3 2 1 TOTAL 16. Plan/elevation with 20-29% masonry x 17. Plan/elevation with 30% or greater masonry x 18. Porte-cochere over driveway x 19. Functioning or simulated x 20. Change in siding style between home and roof gable ends x 21. Decorative material on at least one gable end facing a street (e.G., Decorative vents, x lentils, etc.) 22. Garage not visible on front elevation x 23. Provide wide fascia at least four inches (nominal) – materials around doors, windows x and 24. Ranch plan offered x PORCHES, STOOPS AND ENHANCEMENTS 3 2 1 TOTAL 25. Covered porch of at least 50 square feet on the front elevation x 26. Porch of at least 50 square feet on the front elevation x 27. Wraparound porch, at least six feet deep x 28. Second story porch (at least 25 square feet) x 29. Walk out back covered of at least 50 square feet. x 30. Eight-inch wide , as measured at the base of the column, on front or side x porch 31. Porch or railings x 32. Public view – landscape enhancements in yards that face streets, parks, golf courses, x or open space

ARCHITECTURAL FEATURES POINT TOTAL ______

5 TABLE 13.2. CONSERVATION FEATURES

CONSERVATION AND INDOOR AIR QUALITY FEATURES 3 2 1 TOTAL 1. Photovoltaic panel installed x 2. Solar thermal solar panel installed x 3.* Home energy rating system (hers) index greater than 90 and less than or equal to 95* x 4.* Hers index greater than 85 and less than or equal to 90* x 5.* Hers index greater than 75 and less than or equal to 85* x 6.* Hers index less than or equal to 75* 5 pts 7.* Energy star certified home** 5 pts 8. National standard/ansi standard icc 700 or leed for homes, bronze level x or equivalent minimum 9.* Stated efficiency greater than .78 To .95 Afue* x 10.* Stated furnace efficiency greater than .95 Afue * x 11.* Stated water heater efficiency between .675 To .82 * x 12.* Stated water heater efficiency of .82 Or more * x 13.* Air conditioner with stated efficiency greater than or equal to 14 seer is included as x standard* 14.* Air conditioner with stated efficiency greater than or equal to 16 seer is included as x standard * 15.* Certified epa water sense home x 16.* All showerheads and hand held showers are 2.0 Gpm or less* x 17.* All showerheads and hand held showers are water sense labeled* x 18.* All lavatory faucets flow rate is 1.5 Gpm or less at 60 psi* x 19.* All lavatory faucets are water sense labeled* x 20.* All toilets are 1.28Gpf or less* x 21.* All toilets are water sense labeled* x 22.* All toilets have dual actuated flushing* x 23.* All toilets have dual actuated flushing and are water sense labeled* x 24. Dishwasher is energy star labeled x 25. Landscape weather-based irrigation controllers are water sense labeled. Audit x required identifying appropriate efficiencies. 26. Design of front landscaped area utilizes water sense budget tool x 27. On-demand hot water systems in accordance with water sense program, including, but not limited to: • Tank less water heater at water-use location • Manifold system with less than ½ gallon bleed-off • Circulating pump on occupant switch x 28. Use of pressure compensating sprinklers with check valves x 29. Irrigation system designed by certified irrigation contractor x 30* Active radon control system* x 31* Passive radon control system* x 32* Heat recovery ventilation/energy recovery ventilation system* x

• The folowing items are mutually exclusive: (i) 3, 4, 5, 6 and 7; (ii) 9 and 10; 11 and 12; (iii) 13 and 14; (iv) 16 and 17; (v) 18 and 19; (vi) 20, 21, 22, and 23; (vii) 30, 31, and 32.

CONSERVATION FEATURES POINT TOTAL ______

6 TABLE 13.3. POINT CALCULATION

ARCHITECTURAL FEATURES CONSERVATION FEATURES Minimum Point Requirement = 17 Minimum Point Requirement = 8 TOTAL ARCHITECTURAL POINTS ______TOTAL POINTS ACHIEVED ______Conservation Credits ______TOTAL POINTS ACHIEVED ______

Masonry standards for single-family attached townhomes and multiple-family (other than two families) residential development in the city are set forth in table 13.4.

TABLE 13.4. MASONRY STANDARDS

(A) TYPE OF STRUCTURE (B) MINIMUM PERCENTAGE OF MASONRY ON NET FAÇADE AREA (see note 1)

1. Single-family attached EITHER townhomes • 50 Percent shall be clad in brick or stone; or • 75 Percent shall be clad in stucco; or • 75 Percent shall be clad in a combination of stucco and brick, or stucco and stone.

2. Small, medium, and large EITHER: multiple family residential • 60 Percent shall be clad in brick or stone; or • 80 Percent shall be clad in stucco; or • 80 Percent shall be clad in a combination of stucco and brick, or stucco and stone.

NOTE 1. The required minimum percentage of masonry applies to the total net façade area, rather than to each elevation separately.

FOR CITY OF AURORA USE ONLY Approval Information: Type of Approval:______Authorized Signature:______, Date______Planner Attachments: £ Exhibit A – Permit Application £ Exhibit B – Plans - Architectural Elevations and required information found herein. See pg. 1 Exterior Elevation Review

Check List for paper and digital submittals £ Exhibit C – Copy of Table 13.1 Architectural Features, and Table 13.2 Conservation Features provided herein.