The better way to buildTM
Installation Manual NAILBASE PANELS June 2021
NAILBASE SIPs Installation Manual
Table of Contents Topics General Requirements ...... 3 Materials ...... 3
Details Air Barrier Details for Nailbase Panel Butt Joint ...... AB-1(NB) Nailbase Panel Retrofi t Over Existing Wall Sheathing ...... NB-1 Retrofi t Nailbase Panel Outside Corner ...... NB-2 Retrofi t Nailbase Panel Over Rim Joist ...... NB-3 Inside Corner Detail ...... NB-4 Retrofi t Nailbase Panel Edges ...... NB-5 Window Mounted at Exterior Plane (Header) ...... NB-6A Window Mounted at Exterior Plane (Sill) ...... NB-6B Window Left in Place (Header) ...... NB-7A Window Left in Place (Sill) ...... NB-7B Nailbase Wall Attachment: Concrete or Masonry Wall ...... NB-8 Exterior Wall Cladding: Brick & Stucco ...... NB-9 Exterior Wall Cladding: Vinyl & Wood Siding ...... NB-10 Electrical Wire Fastened to Nailbase Panel ...... NB-11 Pre-Fabricated Metal Chimney Installation in Wall ...... NB-12 Retrofi t Nailbase Panels on Roof Structure ...... NB-13 Retrofi t Roof & Wall Nailbase Connection at Overhang ...... NB-14 Nailbase Roof Overhang Details ...... NB-15 Nailbase Panel Attic Air Block ...... NB-16 Sloped Roof Applied to Nailbase SIPs ...... NB-17 Flat Roof Applied to Nailbase SIPs ...... NB-18 Nailbase Ceiling Panel ...... NB-19 LED Pot Light Installation in Ceiling SIPs ...... NB-20 Electrical Wire Fastened to Nailbase Roof SIP ...... NB-21 Pre-Fabricated Metal Chimney - Roof Installation ...... NB-22 Screw Fastener Detail for Securing Load to Nailbase Ceiling . NB-23
Steel Frame Nailbase Installation Typical Wall Detail ...... IN-1 Gable & Corner Trim Detail ...... IN-2 Peak & High Wall Detail ...... IN-3 Header & Trim @ Self Framing Walkdoor ...... IN-4 Header & Jamb Trim @ Overhead Door ...... IN-5
Nailbase SIP - Installation Manual 2 June 2021
NAILBASE SIPs Installation Manual
1. General Requirements 1.1 Scope The basic design and construction requirements for the Thermapan Nailbase retrofi t panel system is set forth in this specifi cation.
Criteria for materials, environmental control, design loads, and structural design are included. Where requirements are based on internationally recognized standards and specifi cations, these standards and specifi cations are referenced without elaboration.
Installers shall reference engineering design package for fastening arrangements.
2. Materials 2.1 The Thermapan Nailbase SIP is composed of an expanded polystyrene (EPS) foam core laminated on one side with a layer of oriented strand board (OSB) with a structural adhesive.
2.2 Framing Lumber shall be DOC PS 20 or NLGA No.2 or better.
2.3 SIP screws shall conform to ICC-AC233.
2.4 Polyethylene (Poly) Sheathing shall conform to CAN/CGSB-37.2, CAN/CGSB-37.16, or ASTM D 4397.
2.5 Low expansion foam seal shall conform to AAMA 812-04.
2.6 Sill seal gasket is a fl exible polyethylene foam gasketing strip that can help reduce air infi ltration between a concrete or masonry surface and a lumber plate.
Nailbase SIP - Installation Manual 3 EXPANDABLE FOAM SEALANT
NAILBASE PANEL
NAILBASE PANEL
CONTINUOUS POLY SHEATHING
EXISTING WALL OR ROOF (AND SHEATHING)
TITLE PROJECT AIR BARRIER DETAILS FOR NAILBASE PANEL BUTT JOINT
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 AB-1(NB) EXISTING WOOD FRAME WALL & INSULATION
NAILBASE PANEL
BARRIER
EXTERIOR CLADDING
CONTINOUS POLY SHEATHING
NOTE: SEE NB-10 & NB-11 FOR EXTERIOR CLADDING OPTIONS
TITLE PROJECT NAILBASE PANEL RETROFIT OVER EXISTING WALL SHEATHING
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-1 EXISTING WOOD FRAME WALL & INSULATION
NAILBASE PANEL
CONTINOUS POLY SHEATHING
APPLY SEALANT NAILBASE PANEL RECESS EPS AND AS PER OVERLAP WITH DRAWING AB-1 WOOD BLOCKING
FASTENERS PER ENGINEERED SHOP DRAWINGS
TITLE PROJECT RETROFIT NAILBASE PANEL OUTSIDE CORNER
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-2 EXISTING WOOD FRAME EXISTING WOOD FRAME WALL & INSULATION WALL & INSULATION CONTINOUS CONTINOUS POLY SHEATHING POLY SHEATHING
NAILBASE NAILBASE PANEL PANEL
FASTENERS PER ENGINEERED SHOP DRAWINGS
FASTENERS PER ENGINEERED SHOP DRAWINGS
RIM RIM JOIST JOIST FLASHING
FOUNDATION FLASHING
RECOMMENDED ALTERNATE
TITLE PROJECT RETROFIT NAILBASE PANEL OVER RIM JOIST
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-3 EXISTING WOOD FRAME WALL & INSULATION
APPLY SEALANT AS PER DRAWING AB-1
NAILBASE PANEL
FASTENERS PER ENGINEERED SHOP DRAWINGS
CONTINOUS POLY SHEATHING
TITLE PROJECT
INSIDE CORNER DETAIL
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-4 NAILBASE PANELS OVER CONTINOUS POLY SHEATHING (TWO 4x16 PANELS & ONE CUT 1X16 PANEL SHOWN)
FASTENERS PER ENGINEERED SHOP DRAWINGS
TITLE PROJECT RETROFIT NAILBASE PANEL EDGES
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-5 NAILBASE PANEL FULLY ADHERED SHEATHING MEMBRANE WOOD FURRING STRIP EXTENDED INTO ROUGH OPENING (AIR BARRIER SYSTEM) WATER-RESISTIVE BARRIER EXISTING STRUCTURE
SLOPED METAL HEAD FLASHING TO FURRING STRIPS
EXTERIOR WINDOW TRIM FASTENED TO FURRING STRIPS
SHEATHING TAPE OVER HEAD FLASHING CONTINUOUS BEAD OF SEALANT SELF-ADHERED HEAD BETWEEN EXTENSION BOX AND FLASHING OVER FLANGE MEMBRANE (AIR BARRIER SYSTEM) METAL STRAP ANCHOR PLYWOOD/OSB EXTENSION BOX (CAULK INTERIOR CORNERS) LOW EXPANSION FOAM SEALANT AT INTERIOR PERIMETER BETWEEN WINDOW AND EXTENSION BOX (AIR BARRIER SYSTEM)
NOTE: SEE NB-6B FOR SILL DETAIL
TITLE PROJECT WINDOW MOUNTED AT EXTERIOR PLANE (HEADER)
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-6A LOW EXPANSION FOAM SEALANT AT INTERIOR PERIMETER BETWEEN BEVELED SIDING SLOPED SILL WINDOW AND PAN FLASHING (AIR BARRIER SYSTEM) CONTINUOUS SEALANT PLASTIC SHIM BETWEEN BACK DAM OF SILL PAN AND EXTENSION BOX SEALANT BETWEEN WINDOW AND (AIR BARRIER SYSTEM) SILL TRIM TO MINIMIZE WATER PENETRATION AT SILL JOINT CONTINUOUS BEAD OF SEALANT SILL TRIM BETWEEN EXTENSION BOX AND MEMBRANE (AIR BARRIER SYSTEM) PRE-MANUFACTURED PAN FLASHING WITH BACK DAM FULLY ADHERED SHEATHING MEMBRANE EXTENDED INTO PLYWOOD/OSB EXTENSION BOX ROUGH OPENING (CAULK INTERIOR CORNERS) (AIR BARRIER SYSTEM)
WOOD FURRING STRIP
EXISTING STRUCTURE NAILBASE PANEL
NOTE: SEE NB-6A FOR HEADER DETAIL
TITLE PROJECT WINDOW MOUNTED AT EXTERIOR PLANE (SILL)
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-6B NAILBASE PANEL
TREATED WOOD FURRING STRIP WATER-RESISTIVE BARRIER WATER-RESISTIVE BARRIER EXISTING STRUCTURE
SLOPED METAL HEAD FLASHING OVER TOP OF HEAD TRIM, FASTENED TO FURRING STRIPS SELF-ADHERED HEAD FLASHING; BUTTER TOP EDGE OF HEAD EXTERIOR WINDOW TRIM FLASHING WITH COMPATIBLE FASTENED TO FURRING STRIPS MASTIC TO REINFORCE SEAL WITH CLADDING VENT BETWEEN SHEATHING MEMBRANE FURRING STRIPS AT WINDOW HEAD LOW EXPANSION SEALANT AT INTERIOR PERIMETER BETWEEN HEAD OF TRIM EXTENSION BOX WINDOW AND ROUGH OPENING CUT 1” ON EACH SIDE FRAMING TO ALLOW DRAINAGE FULLY ADHERED SHEATHING MEMBRANE EXTENDED INTO DO NOT CAULK TRIM EXTENSION ROUGH OPENING BOX TO WINDOW HEAD
NOTE: SEE NB-7B FOR SILL DETAIL
TITLE PROJECT WINDOW LEFT IN PLACE (HEADER)
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-7A PRE-MANUFACTURED PAN FLASHING WITH BACK DAM
LOW EXPANSION FOAM SEALANT AT INTERIOR BETWEEN WINDOW AND PAN FLASHING
PLASTIC SHIM
SEALANT BETWEEN WINDOW AND SILL TRIM TO MINIMIZE WATER CONTINUOUS SEALANT PENETRATION AT SILL JOINT BEVELED SIDING SLOPED SILL SILL OF TRIM EXTENSION BOX
DO NOT APPLY FLASHING MEMBRANE OVER BOTTOM FULLY ADHERED SHEATHING FLANGE, ALLOW DRAINAGE; PLACE MEMBRANE EXTENDED INTO WASHER (UNDER EACH SCREW) OPENING OVER BEVELED SILL BETWEEN FLANGE AND FLASHING MEMBRANE FOR DRAINAGE SPACE
WATER-RESISTIVE BARRIER EXISTING STRUCTURE TREATED WOOD FURRING STRIP
NAILBASE PANEL
NOTE: SEE NB-7A FOR HEADER DETAIL
TITLE PROJECT WINDOW LEFT IN PLACE (SILL)
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-7B SIP SCREW FASTENED TO STRAPPING
WOOD STRAPPING NAILBASE WALL PANEL WOOD SILL SEAL STRAPPING GASKET 16'-0 (4876mm)
MASONRY SCREW OR NAIL FASTENING STRAPPING TO CONCRETE. 4'-0" (1220mm) FASTEN SIP SCREWS AS PER ENGINEERED EXTERIOR DRAWINGS WOOD STRAPPING MASONRY OR CONCRETE WALL APPLY FOAM SEAL BETWEEN ALL PANEL JOINTS 4'-0" (1220mm)
WOOD STRAPPING
GAP BETWEEN NAILBASE PANEL AND CONCRETE ELEVATION SECTION WALL SUITABLE FOR ELECTRICAL
TITLE PROJECT NAILBASE WALL ATTACHMENT (CONCRETE OR MASONRY WALL)
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-8 MASONRY VENEER
THERMAPAN CORROSION RESISTANT NAILBASE NON-ADHERING 2” RING NAILS OR #8 (MINIMUM) SCREWS WALL PANEL BREATHABLE WITH FULL THREAD PENETRATION INTO OSB WEATHER OSB RESISTIVE BARRIER SHEATHING OF SIP LAP BARRIER AT JOINTS MASONRY TIES INSTALLED @ 24” (600mm) O/C VERTICALLY & 16” (400 mm) O/C HORIZONTALLY (MAXIMUM) AS PER BUILDING CODE
BRICK VENEER BRICK SUPPORTED VENEER ON STEEL ANGLE OR BRICK LEDGE
1” AIR NON-ADHERING SPACE BREATHABLE WEATHER RESISTIVE BARRIER OSB EPS
STUCCO
THERMAPAN STUCCO NAILBASE WRAP WALL PANEL
OSB 2 LAYERS SHEATHING NON-ADHERING OF SIP BREATHABLE WEATHER RESISTIVE BARRIER
BROWN COAT
STUCCO FINISH COAT SCRATCH WIRE COAT NON-ADHERING LATH BREATHABLE WEATHER RESISTIVE BARRIER
TITLE PROJECT EXTERIOR WALL CLADDING BRICK & STUCCO
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-9 VINYL SIDING
THERMAPAN NAILBASE NON-ADHERING WALL PANEL BREATHABLE WEATHER RESISTIVE BARRIER FIBRE CEMENT OSB SIDING SHEATHING FOR FIBRE CEMENT LAP SIDING OF SIP LAP BARRIER AT REFER TO MANUFACTURER’S JOINTS RECOMMENDED FASTENING METHODS. VINYL SIDING
MINIMUM 1-1/2” NAILS OR STAPLES @ 16” MAX INTO OSB
WOOD SIDING NON-ADHERING THERMAPAN BREATHABLE WEATHER NAILBASE RESISTIVE BARRIER WALL PANEL
OSB WOOD SHEATHING FURRING FURRING REQUIREMENTS OF SIP FURRING FASTENER SPACING FASTENER SPACING SPACING (MIN 1-1/2” SCREWS) (MIN 1-1/4” NAILS)
WOOD 16” O/C 10” O/C 8” O/C SIDING 24” O/C 8” O/C 8” O/C
NOTE: ALL NAILS TO BE RING (ANNULARLY THREADED). FURRING TO BE AS RECOMMENDED BY SIDING MANUFACTURER.
LAP BARRIER AT JOINTS
TITLE PROJECT EXTERIOR WALL CLADDING: SIDING
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-10 MASONRY VENEER ELECTRICAL WIRE FASTENED TO OSB BENEATH MEMBRANE
MASONRY TIES INSTALLED @ 24” (600mm) O/C VERTICALLY & CORROSION RESISTANT 16” (400 mm) O/C HORIZONTALLY 2” RING NAILS OR #8 (MINIMUM) SCREWS (MAXIMUM) WITH FULL THREAD PENETRATION INTO OSB AS PER BUILDING CODE
BRICK VENEER
NON-ADHERING BREATHABLE WEATHER RESISTIVE BARRIER OSB EPS
WOOD SIDING
WOOD SIDING
VERTICAL STRAPPING 16” O/C OR AS PER ELECTRICAL WIRE FASTENED TO SIDING SPECIFICATIONS OSB BENEATH MEMBRANE
GAP THROUGH STRAPPING
NON-ADHERING EPS BREATHABLE WEATHER RESISTIVE BARRIER OSB
TITLE PROJECT ELECTRICAL WIRE FASTENED TO NAILBASE SIP EXTERIOR
REFERENCE SCALE N.T.S. www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) MARCH 2021 NB-11 SHIELD COLLAR AS PER CHIMNEY MANUFACTURER
AIR GAP AS SPECIFIED BY CHIMNEY MANUFACTURER
CHIMNEY
FINISHING COLLAR
INTERIOR WALL FINISH
THERMAPAN NAILBASE PANEL
NOTE: ABOVE DETAILS ARE TYPICAL REQUIREMENTS TO INSTALL A PREFABRICATED METAL CHIMNEY IN A THERMAPAN STRUCTURAL INSULATED PANEL. THE CHIMNEY INSTALLATION MUST COMPLY WITH THE CHIMNEY MANUFACTURERS’S SPECIFICATION AND THE APPLICABLE BUILDING CODE.
TITLE PROJECT PRE-FABRICATED METAL CHIMNEY INSTALLATION IN WALL
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) OCTOBER 2019 NB-12 FASTENERS PER ENGINEERED SHOP DRAWINGS
4X16 NAILBASE PANELS OVER CONTINUOUS POLY SHEATHING
TRUSSES OR RAFTERS 24” O.C. (TYPCIAL)
TITLE PROJECT RETROFIT NAILBASE PANELS ON ROOF STRUCTURE
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-13 STEP 1 STEP 2 ANALYSE CONSTRUCTION DETAIL REMOVE OVERHANG PORTION AS SHOWN REMOVE ROOF PLY, TRUSS OVERHANG FACIA AND SOFFIT AS REQUIRED AT FACE OF WALL SHEATHING EXISTING PLY ROOF DECK
EXISTING CUT AND TRUSS SYSTEM REMOVE
INTERIOR FINISH EXISTING WALL EXISTING WALL SHEATHING
TYPICAL EAVE CONSTRUCTION DETAIL
STEP 3 STEP 4 INSTALL NAIL BASE WALL PANEL INSTALL NAIL BASE ROOF PANEL AND VAPOUR BARRIER ON ROOF BLIND FACIA AND SOFFIT TO INSTALL NAIL BASE PANEL ONTO WALL SHEATHING. CREATE OVERHANG SECURE PANEL TO TOP PLATE AS SHOWN AND INSTALL 2X3 FRAMING AT 24" OC TO SUPPORT SOFFIT AND BLIND FACIA SIP SCREWS CONTINUOUS POLY SHEATHING NAILBASE ROOF PANEL SECURE NAILBASE PANEL TO ONE OF EXISTING TOP PLATES WITH SIP SCREWS BLIND FACIA
NAILBASE PANEL SOFFIT FRAMING SIP AT 24" SCREWS OC MAX
30”MAX
TITLE PROJECT RETROFIT ROOF & WALL NAILBASE CONNECTION AT OVERHANG
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-14 TYPICAL EXISTING ROOF SHEATHING SOFFIT ASSEMBLY
EXISTING WALL SHEATHING EXISTING TRUSS EXISTING GABLE TRUSS
TYPICAL GABLE OVERHANG CONSTRUCTION DETAIL
TYPICAL EXISTING ROOF SHEATHING SOFFIT ASSEMBLY
EXISTING WALL SHEATHING EXISTING TRUSS EXTERIOR LIMIT OF EXISTING GABLE TRUSS NAILBASE WALL PANEL
OVERHANG ADJUSTMENT FOR NAIL BASE ATTACHMENT
NOTCH AND GROOVE NAILBASE PANEL TO FIT OVER NAILBASE EXISTING OVERHANG LADDER ROOF PANEL
SIP SCREWS CONTINOUS POLY SHEATHING TYPICAL EXISTING SOFFIT ASSEMBLY ROOF SHEATHING
SIP SCREWS EXISTING WALL SHEATHING EXISTING TRUSS EXISTING GABLE TRUSS
CUT AND REMOVE SOFFIT AS REQUIRED NAILBASE FOR NAIL BASE GAP WALL PANEL
NAIL BASE WALL AND ROOF INSTALLATION FOR TYPICAL GABLE OVERHANG INSTALLATION
TITLE PROJECT NAILBASE ROOF OVERHANG DETAILS
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-15 PLAN VIEW AT STEP 2 STEPS
1 CUT EXISTING ROOF SHEATHING AS REQUIRED
2 INSERT, FASTEN AND SEAL AIR BLOCK ROOF TRUSS SIZED FROM NAILBASE PANEL (ENSURE (ROOF RAFTER) BLOCKING FIT IS SUCH TO PREVENT AIR LEAKAGE WHEN SHEATHING IS RE-INSTALLED)
3 SEAL AND FASTEN ROOF SHEATHING CUT PIECE TO ROOF RAFTER WITH FASTENERS
4 APPLY NAILBASE PANEL (SEE NB-12)
CONTINUOUS CAULK BEADS SECURE SHEATHING ALONG FACE OF RAFTER 3 TO ROOF RAFTER AND AIR BLOCK PANEL WITH FASTENERS.
AIR BLOCK PANEL EPS CUT ROOF AIR BLOCK PANEL OSB SHEATHING SECTION VIEW
4 NAILBASE EXISTING PANEL ROOF SHEATHING
1 CUT ROOF SHEATHING 3 (SEE PLAN VIEW)
INSULATED AIRBLOCK 2 SIZED FROM NAILBASE PANEL FOAM SEAL AS REQUIRED*
CONTINUOUS CAULK ROOF TRUSS BEADS ALONG TOP AND BOTTOM OF AIR BLOCK PANEL*
EXISTING WALL (TYPICAL CONSTRUCTION) *NOTE: REFER TO AIR BARRIER (AB-3) DETAILS FOR SEALING NAILBASE PANEL CONNECTIONS.
TITLE PROJECT NAILBASE PANEL ATTIC AIR BLOCK
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) MARCH 2020 NB-16 THERMAPAN NAILBASE ROOF PANELS ASPHALT (TWO SHOWN) SHINGLES
NON-ADHERING BREATHABLE ROOFING UNDERLAYMENT INSTALLED AS PER MANUFACTURER’S DRIP EDGE INSTRUCTIONS
FASCIA COVER
2X_ FASCIA BOARD
DRIP EDGE STARTER SHINGLE INSTALLED AS PER MANUFACTURER’S FASCIA WEDGE INSTRUCTIONS FASCIA FOR PLUMB CUT BOARD 2X_ BLIND FASCIA FASCIA COVER
THERMAPAN METAL ROOFING OR NAILBASE CEDAR SHAKES ROOF PANELS (TWO SHOWN)
NON-ADHERING BREATHABLE ROOFING UNDERLAYMENT INSTALLED AS PER MANUFACTURER’S DRIP EDGE INSTRUCTIONS
FASCIA COVER FURRING INSTALLED AS PER MANUFACTURER’S 2X_ FASCIA BOARD INSTRUCTIONS
DRIP METAL ROOFING OR EDGE SHAKES INSTALLED AS PER MANUFACTURER’S FASCIA WEDGE INSTRUCTIONS FASCIA FOR PLUMB CUT BOARD 2X_ BLIND FASCIA FASCIA COVER
NOTE: VENTILATION OF ROOF NOT REQUIRED.
TITLE PROJECT SLOPED ROOFING APPLIED TO NAILBASE SIPS
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-17 NON-ADHERED MEMBRANE (EPDM, PVC, TPO, ETC.)
FASTENERS INTO OSB
PROTECTIVE SHEATHING OR MEMBRANE AS REQUIRED
OSB
EPS
ADHERED ROOFING MEMBRANE
TORCHED ON OR GLUED ON ROOFING MEMBRANE
OSB
EPS
NOTES: • NAILBASE SIP SURFACE TO BE DRY. • INSTALL MEMBRANE ACCORDING TO MEMBRANE MANUFACTURER’S DETAILS AND CONFORM TO REQUIREMENTS OF LOCAL BUILDING CODE.
TITLE PROJECT FLAT ROOFING APPLIED TO NAILBASE SIPS
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-18 TRUSS SYSTEM - FLAT CEILING (W, M, GABLE, ETC.) TRUSS SYSTEM
CAULK
CAP AND/OR PLATE
THERMAPAN SEE DRAWING 1" NAIL BASE PANEL W-3 FOR CAP AND/OR PLATES
SIP SCREW CONTINUOUS POLY SHEATHING EXPANDABLE INTERIOR FOAM SEALANT FINISH
TRUSS SYSTEM - SCISSORS CAULK
CUT PANEL ON ANGLE WITH PRAZI SAW TO SIP SCREW THERMAPAN BUTT UP ON NAIL BASE PANEL WALL
SEE DRAWING W-3 FOR CAP AND/OR PLATES
EXPANDABLE FOAM SEALANT CONTINUOUS POLY SHEATHING
INTERIOR FINISH
NOTES: SIP SCREWS TO BE INSTALLED EVERY 2’ O/C BOTH DIRECTIONS. REFER TO AIR BARRIER (AB-3) DETAILS FOR SEALING NAILBASE PANEL CONNECTIONS.
TITLE PROJECT
NAILBASE CEILING PANEL
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-19 DRIVER BOX
WIRING STRAPPING
LED RECESS CEILING FIXTURE* INTERIOR FINISH
* FIXTURE SPECIFICATIONS FIXTURE TO HAVE AMBIENT OPERATING TEMPERATURE +140F(+40C) MAXIMUM INSTALL AS PER MANUFACTURERS SPECIFICATIONS
PROJECT TITLE LED POT LIGHT INSTALLATION IN CEILING SIPS
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) NOVEMBER 2018 NB-20 METAL ROOFING OR CEDAR SHAKES
STRAPPING 16” O/C OR AS PER ROOFING SPECIFICATIONS
NON-ADHERING METAL ROOFING BREATHABLE ROOFING (OR SHAKES) INSTALLED UNDERLAYMENT AS PER MANUFACTURER’S INSTALLED AS PER INSTRUCTIONS MANUFACTURER’S INSTRUCTIONS
EPS
OSB ELECTRICAL WIRE FASTENED TO OSB BENEATH MEMBRANE
TITLE PROJECT ELECTRICAL WIRE FASTENED TO NAILBASE ROOF SIP
REFERENCE SCALE N.T.S. www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) MARCH 2021 NB-21 AIR GAP AS SPECIFIED BY CHIMNEY MANUFACTURER
WEATHER COLLAR AS PER CHIMNEY MANUFACTURER
CHIMNEY SUPPORT BOX AS PER CHIMNEY MANUFACTURER
THERMAPAN NAILBASE PANEL
INTERIOR WALL FINISH
TRIM COLLAR
2X__ BLOCKING AS PER PANEL THICKNESS AND OPENING SPECIFIED BY CHIMNEY MANUFACTURER
NOTE: ABOVE DETAILS ARE TYPICAL REQUIREMENTS TO INSTALL A PREFABRICATED METAL CHIMNEY IN A THERMAPAN STRUCTURAL INSULATED PANEL. THE CHIMNEY INSTALLATION MUST COMPLY WITH THE CHIMNEY MANUFACTURERS’S SPECIFICATION AND THE APPLICABLE BUILDING CODE.
TITLE PROJECT PRE-FABRICATED METAL CHIMNEY - ROOF INSTALLATION
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) OCTOBER 2019 NB-22 TYPICAL SIP ROOF SECTION
ELECTRICAL BOX (OPTIONAL) THERMAPAN PANEL
SEE DETAIL A
FIXTURE FINISH CAP
FIXTURE FASTENING PLATE
THERMAPAN NAILBASE LOAD PANEL OSB SKiN
CEILING FINISH (DRYWALL OR WOOD PANELLING)
CEILING LOAD RESISTANCE CAN BE ACHIEVED WITH NUMBER 10 SHEET METAL SCREWS INSTALLED TO A SIP CEILING FINISH AS PANEL EPS LAYER DETAILED OR TO THE SIP SKIN DIRECTLY.
EACH SCREW CAN RESIST A PULL OUT OF PANEL OSB SKIN 90 POUNDS IN 7/16" OSB. CONTRACTOR TO CONFIRM LOAD TO BE SECURED AND NUMBER OF FASTENERS REQUIRED. MINIMUM 4 SCREWS CEILING FINISH PER FIXTURES. FULL THICKNESS OF OSB TO RECEIVE SCREW THREAD ON ANGLE AS DETAILED
DETAIL A
TITLE PROJECT SCREW FASTENER DETAIL FOR SECURING LOAD TO NAILBASE CEILING PANEL
REFERENCE SCALE
N.T.S.
www.thermapan.com DATE REVISION DWG. No. 1-877-443-WALL (9255) FEBRUARY 2020 NB-23 C DEÿ F ÿ ""$ÿE )"ÿE ÿGF 1