ROOF SYSTEM DESIGN GUIDE Featuring Trus Joist® Timberstrand® LSL, Microllam® LVL, and Parallam® PSL
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Sealing Air Leaks and Adding Attic Insulation
For more information United States Office of Air and Radiation www.energystar.gov. Environmental (6202A) EPA 430-F-04-024 Protection Agency July 2016 Recycled/Recyclable – Printed with Vegetable Oil Based Inks on Recycled Paper (Minimum 50% Post-consumer Content) A DO-IT-YOURSELF GUIDE TO SEALING AND INSULATING WITH ENERGY STAR® SEALING AIR LEAKS AND ADDING ATTIC INSULATION CONTENTS Locating Air Leaks 1.2 Getting Started 1.4 Sealing Attic Air Leaks 1.6 Additional Sources of Air Leaks 2.1 Sealing Basement Air Leaks 3.1 Adding Attic Insulation 4.1 Sealing and Insulating your home is When you see products or services with ® one of the most cost-effective ways the ENERGY STAR label, you know they to make a home more comfortable meet strict energy efficiency guidelines and energy efficient—and you can set by the U.S. Environmental Protection do it yourself. Agency (EPA) and the U.S. Department of Energy (DOE). Since using less energy Use This Guide To: reduces greenhouse gas emissions and improves air quality, choosing ENERGY 1. Learn how to find and seal hidden STAR is one way you can do your part to attic and basement air leaks protect our planet for future generations. 2. Determine if your attic insulation is adequate, and learn how to For more information visit: add more www.energystar.gov. 3. Make sure your improvements The U.S. EPA wishes to thank The Family are done safely Handyman Magazine for their contribution 4. Reduce energy bills and help of photographs and content for this guide. -
LP Solidstart LVL Technical Guide
U.S. Technical Guide L P S o l i d S t a r t LV L Technical Guide 2900Fb-2.0E Please verify availability with the LP SolidStart Engineered Wood Products distributor in your area prior to specifying these products. Introduction Designed to Outperform Traditional Lumber LP® SolidStart® Laminated Veneer Lumber (LVL) is a vast SOFTWARE FOR EASY, RELIABLE DESIGN improvement over traditional lumber. Problems that naturally occur as Our design/specification software enhances your in-house sawn lumber dries — twisting, splitting, checking, crowning and warping — design capabilities. It ofers accurate designs for a wide variety of are greatly reduced. applications with interfaces for printed output or plotted drawings. Through our distributors, we ofer component design review services THE STRENGTH IS IN THE ENGINEERING for designs using LP SolidStart Engineered Wood Products. LP SolidStart LVL is made from ultrasonically and visually graded veneers arranged in a specific pattern to maximize the strength and CODE EVALUATION stifness of the veneers and to disperse the naturally occurring LP SolidStart Laminated Veneer Lumber has been evaluated for characteristics of wood, such as knots, that can weaken a sawn lumber compliance with major US building codes. For the most current code beam. The veneers are then bonded with waterproof adhesives under reports, contact your LP SolidStart Engineered Wood Products pressure and heat. LP SolidStart LVL beams are exceptionally strong, distributor, visit LPCorp.com or for: solid and straight, making them excellent for most primary load- • ICC-ES evaluation report ESR-2403 visit www.icc-es.org carrying beam applications. • APA product report PR-L280 visit www.apawood.org LP SolidStart LVL 2900F -2.0E: AVAILABLE SIZES b FRIEND TO THE ENVIRONMENT LP SolidStart LVL 2900F -2.0E is available in a range of depths and b LP SolidStart LVL is a building material with built-in lengths, and is available in standard thicknesses of 1-3/4" and 3-1/2". -
Carpentry/Carpenter
Job Ready Credential Blueprint 46.0201- Carpentry/Carpenter Carpentry Code: 4215 / Version: 01 Copyright © 2017. All Rights Reserved. Carpentry General Assessment Information Blueprint Contents General Assessment Information Sample Written Items Written Assessment Information Performance Assessment Information Specic Competencies Covered in the Test Sample Performance Job Test Type: The Carpentry industry-based credential is included in NOCTI’s Job Ready assessment battery. Job Ready assessments measure technical skills at the occupational level and include items which gauge factual and theoretical knowledge. Job Ready assessments typically oer both a written and performance component and can be used at the secondary and post-secondary levels. Job Ready assessments can be delivered in an online or paper/pencil format. Revision Team: The assessment content is based on input from secondary, post-secondary, and business/industry representatives from the states of Maine, Massachusetts, Michigan, Montana, Pennsylvania, and Texas. CIP Code 46.0201- Carpentry/Carpenter Career Cluster 2- Architecture and Construction 47-2031.01 – Construction Carpenters The Association for Career and Technical Education (ACTE), the leading professional organization for career and technical educators, commends all students who participate in career and technical education programs and choose to validate their educational attainment through rigorous technical assessments. In taking this assessment you demonstrate to your school, your parents and guardians, your -
Western BCI ® and VERSA-LAM ® Specifier Guide
WESTERN SPECIFIER GUIDE for products manufactured in White City, Oregon WSG 03/14/2013 2 The SIMPLE FRAMING SYSTEM® Makes Designing Homes Easier Architects, engineers, and designers trust Boise Cascade's engineered wood products to provide a better system for framing floors and roofs. It's the SIMPLE FRAMING SYSTEM®, conventional framing methods when crossventila tion and wiring. featuring beams, joists and rim boards the resulting reduced labor and Ceilings Framed with BCI® Joists materials waste are con sidered. that work together as a system, so you The consistent size of BCI® Joists spend less time cutting and fitting. In There's less sorting and cost associ ated with disposing of waste because helps keep gypsum board flat and fact, the SIMPLE FRAMING SYSTEM® you order only what you need. free of unsightly nail pops and ugly uses fewer pieces and longer lengths Although our longer lengths help your shadows, while keeping finish work than conventional framing, so you'll clients get the job done faster, they to a minimum. complete jobs in less time. cost no more. VERSALAM® Beams for Floor You'll Build Better Homes Environmentally Sound and Roof Framing with the These highlystable beams are ® As an added bonus, floor and roof free of the largescale defects that SIMPLE FRAMING SYSTEM ® systems built with BCI Joists require plague dimension beams. The Now it's easier than ever to design about half the number of trees as and build better floor systems. When result is quieter, flatter floors (no those built with dimension lumber. -
UFGS 06 10 00 Rough Carpentry
************************************************************************** USACE / NAVFAC / AFCEC / NASA UFGS-06 10 00 (August 2016) Change 2 - 11/18 ------------------------------------ Preparing Activity: NAVFAC Superseding UFGS-06 10 00 (February 2012) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated July 2021 ************************************************************************** SECTION TABLE OF CONTENTS DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES SECTION 06 10 00 ROUGH CARPENTRY 08/16, CHG 2: 11/18 PART 1 GENERAL 1.1 REFERENCES 1.2 SUBMITTALS 1.3 DELIVERY AND STORAGE 1.4 GRADING AND MARKING 1.4.1 Lumber 1.4.2 Structural Glued Laminated Timber 1.4.3 Plywood 1.4.4 Structural-Use and OSB Panels 1.4.5 Preservative-Treated Lumber and Plywood 1.4.6 Fire-Retardant Treated Lumber 1.4.7 Hardboard, Gypsum Board, and Fiberboard 1.4.8 Plastic Lumber 1.5 SIZES AND SURFACING 1.6 MOISTURE CONTENT 1.7 PRESERVATIVE TREATMENT 1.7.1 Existing Structures 1.7.2 New Construction 1.8 FIRE-RETARDANT TREATMENT 1.9 QUALITY ASSURANCE 1.9.1 Drawing Requirements 1.9.2 Data Required 1.9.3 Humidity Requirements 1.9.4 Plastic Lumber Performance 1.10 ENVIRONMENTAL REQUIREMENTS 1.11 CERTIFICATIONS 1.11.1 Certified Wood Grades 1.11.2 Certified Sustainably Harvested Wood 1.11.3 Indoor Air Quality Certifications 1.11.3.1 Adhesives and Sealants 1.11.3.2 Composite Wood, Wood Structural Panel and Agrifiber Products SECTION 06 10 00 Page 1 PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Virgin Lumber 2.1.2 Salvaged Lumber 2.1.3 Recovered Lumber -
E-Mount QMSE
E-Mount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ag pull-out (withdrawal) capacities (lbs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16" shaft per 3" thread depth 5/16" shaft per 1" thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. -
Steel Joists and Joist Girders
Steel Joists and Joist Girders • Fully updated to SJI 43rd Edition Standard Specifications • Load and weight tables for K, LH, DLH-Series and Joist Girders • Economical Design Guide load tables for lowest cost joist selection Introduction Table of Contents General JoistGeneral Introduction to Products and Services ....................................... 2 Information General Joist Information ......................................................... 7 SJI Bridging Tables Standard Joist Details Design Guide Sloped Seat Requirements Economical Standard and Special Joist Profiles Duct Opening Sizes Standard Bridging Details OSHA Highlights Ext., K-Series Top Chord Top Standard Joist Girder Details and Notes Load Zone Joists Bill of Materials Instructions Bill of Materials Joist Substitutes & Outriggers Economical Design Guide .......................................................26 LRFD and ASD Design Advantages Definition of Span Economical Load Tables KCS Joists KCS Top Chord Extensions, K-Series .............................................. 67 Joist Substitutes and Outriggers, K-Series ...............................70 Load Tables Load Tables KCS Joists ................................................................................ 74 Joist LRFD Joist LRFD Load Tables ............................................................78 K-Series LH-Series Load Tables DLH-Series Joist ASD Joist ASD Load Tables ............................................................ 91 K-Series LH-Series Tables Weight Load/Load DLH-Series Pages identified -
Residential Hip Roof Framing Using Cold-Formed Steel Members I
Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 2006 American Iron and Steel Institute research report Residential Hip Roof Framing Using Cold-Formed Steel Members i DISCLAIMER The material contained herein has been developed by researchers based on their research findings and is for general information only. The information in it should not be used without first securing competent advice with respect to its suitability for any given application. The publication of the information is not intended as a representation or warranty on the part of the American Iron and Steel Institute, Steel Framing Alliance, or of any other person named herein, that the information is suitable for any general or particular use or of freedom from infringement of any patent or patents. Anyone making use of the information assumes all liability arising from such use. Copyright 2006 American Iron and Steel Institute / Steel Framing Alliance ii Residential Hip Roof Framing Using Cold-Formed Steel Members PREFACE The objectives of this project were to investigate a more rational rafter design methodology for both gable and hip roofs and develop all the necessary tables, details and specification requirements for hip roof framing members and connections for addition to the AISI Standard for Cold-Formed Steel framing – Prescriptive Method for One and Two Family Dwellings [Prescriptive Method]. This report accomplishes these objectives, provides useful insight and suggests future study topics that should assist in identifying and prioritizing future research needs. It is expected that portions of this report will indeed be incorporated in the Prescriptive Method. As such, the results of this work will have a lasting and beneficial impact on the steel- framed residential construction industry. -
Mitek Guidefor ROOF Trussinstallation
TIMBER ROOF TRUSSES MiTek GUIDE for ROOF TRUSS Installation The Timber Roof Trusses you are about to install have been manufactured to engineering standards. To ensure that the trusses perform, it is essential that they be handled, erected and braced correctly. 2019 - Issue 1 mitek.com.au TABLE OF CONTENTS Fixing & Bracing Guidelines For Timber Roof Trusses General .....................................................................................................................................................................................3 Design ......................................................................................................................................................................................3 Transport..................................................................................................................................................................................3 Job Storage ..............................................................................................................................................................................3 Roof Layout .............................................................................................................................................................................4 Erection and Fixing ...................................................................................................................................................................4 Girder and Dutch Hip Girder Trusses .......................................................................................................................................7 -
Ceilings and Attics: Install Insulation and Provide Ventilation
T e c h n o l o g y F a c t S h e e t CEILINGS AND ATTICS Foil-faced batt insulation is often used in bottom plate, seal penetrations through the For more information, contact: CEILINGS AND ATTICS cathedral ceilings because it has a 0.5 perm drywall, etc.). The open joist ends below the Energy Efficiency and rating and provides the permeability often knee wall should be plugged with squares of Install Insulation and Provide Ventilation Renewable Energy required for use in ceilings without attic cardboard, metal flashing, or rigid insulation; Clearinghouse (EREC) 1-800-DOE-3732 spaces. A vent baffle should be installed be- cellulose insulation blown at a high density; or BENEFITS OF CEILING INSULATION www.eren.doe.gov tween the insulation and roof decking to ensure batt insulation stuffed into plastic bags. The Insulating ceilings is one of the most ATTIC VENTILATION that the ventilation channel is maintained. plugs should be sealed to the joists using Or visit the BTS Web site at cost-effective energy efficiency measures. In Continuous ridge and soffit www.eren.doe.gov/buildings caulk or spray foam. If roof framing provides insufficient space for addition to reducing heat loss in the winter and vents form an effective attic Or refer to the Builder’s Guide required insulation, higher insulation values can The knee wall and attic floor in the attic space heat gains in the summer, ceiling insulation ventilation system. Ridge vent Energy Efficient Building be obtained by either attaching furring strips to behind it should be insulated to recommended improves comfort by bringing ceiling tempera- Association, Inc. -
Creating a Timber Frame House
Creating a Timber Frame House A Step by Step Guide by Brice Cochran Copyright © 2014 Timber Frame HQ All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, recording or otherwise, without the prior written permission of the author. ISBN # 978-0-692-20875-5 DISCLAIMER: This book details the author’s personal experiences with and opinions about timber framing and home building. The author is not licensed as an engineer or architect. Although the author and publisher have made every effort to ensure that the information in this book was correct at press time, the author and publisher do not assume and hereby disclaim any liability to any party for any loss, damage, or disruption caused by errors or omissions, whether such errors or omissions result from negligence, accident, or any other cause. Except as specifically stated in this book, neither the author or publisher, nor any authors, contributors, or other representatives will be liable for damages arising out of or in connection with the use of this book. This is a comprehensive limitation of liability that applies to all damages of any kind, including (without limitation) compensatory; direct, indirect or consequential damages; income or profit; loss of or damage to property and claims of third parties. You understand that this book is not intended as a substitute for consultation with a licensed engineering professional. Before you begin any project in any way, you will need to consult a professional to ensure that you are doing what’s best for your situation. -
Ceiling Joist Span Chart—Attics Without Storage
City of Republic—Community Development Ceiling Joist Span Chart—Attics Without Storage Revision Date: January 2017 2012 IRC Table R802.4(1) - Ceiling Joist Spans for Common Lumber Species (Uninhabitable Attics Without Storage, Live Load = 10 psf, L/Δ = 240) Dead Load = 5 psf Ceiling Joist Spacing 2 x 4 2 x 6 2 x 8 2 x 10 Species and Grade Maximum Ceiling Joist Spans (inches) Feet- Feet- Feet- Feet- inches inches inches inches SS 13-2 20-8 Note a Note a #1 12-8 19-11 Note a Note a Douglas Fir-Larch #2 12-5 19-6 25-8 Note a #3 10-10 15-10 20-1 24-6 SS 12-5 19-6 25-8 Note a #1 12-2 19-1 25-2 Note a Hem-Fir #2 11-7 18-2 24-0 Note a #3 10-10 15-10 20-1 24-6 12 SS 12-11 20-3 Note a Note a #1 12-8 19-11 Note a Note a Southern Pine #2 12-5 19-6 25-8 Note a #3 11-6 17-0 21-8 25-7 SS 12-2 19-1 25-2 Note a #1 11-10 18-8 24-7 Note a Spruce-Pine-Fir #2 11-10 18-8 24-7 Note a #3 10-10 15-10 20-1 24-6 SS 11-11 18-9 24-8 Note a #1 11-6 18-1 23-10 Note a Douglas Fir-Larch #2 11-3 17-8 23-0 Note a #3 9-5 13-9 17-5 21-3 SS 11-3 17-8 23-4 Note a #1 11-0 17-4 22-10 Note a Hem-Fir #2 10-6 16-6 21-9 Note a #3 9-5 13-9 17-5 21-3 16 SS 11-9 18-5 24-3 Note a #1 11-6 18-1 23-1 Note a Southern Pine #2 11-3 17-8 23-4 Note a #3 10-0 14-9 18-9 22-2 SS 11-0 17-4 22-10 Note a #1 10-9 16-11 22-4 Note a Spruce-Pine-Fir #2 10-9 16-11 22-4 Note a #3 9-5 13-9 17-5 21-3 Ceiling Joist Span Chart—Attics Without Storage Page 2 2012 IRC Table R802.4(1) - Ceiling Joist Spans for Common Lumber Species (Uninhabitable Attics Without Storage, Live Load = 10 psf, L/Δ = 240) Dead Load