Product Catalog

Total Page:16

File Type:pdf, Size:1020Kb

Product Catalog FIREMAN GARMENTS & FIRE PROXIMITY SUITS EMERGENCY SHOWERS AND EYE-WASH FOUNTAINS SAFETY CANS PRODUCT CATALOG Co. LTD. [email protected] FIREMAN GARMENTS & FIRE PROXIMITY SUITS FYRPRO®, FYRAL®, FYRTEX® TECHNICAL INFORMATION ABOUT OUR PRODUCTIVE GARMENTS FYRPRO® Series FYRPRO® series fireman garments are manufactured as per EN 469:2005 standard and certified as per 89/686/ EEC - PPE as a requirement of European Regulations. What is the meaning of X, Y, Z and Level 1, Level 2 Protection Levels? Two different performance levels are described in EN 469:2005 standard; level 1 and level 2. Level 2 garments provide higher protection than level 1 garments. Garments should be marked according to their performance levels. For example X2, Y2, Z2 indicates level 2 garment or X2, Y2, Z1 indicates level 1 garment. X defines the heat transfer level for flame and radiation. Y defines the water penetration level. Z defines water vapor resistance level. Following table shows related test methods and requirements for level 1 and level 2. PERFORMANCE LEVELS TESTS TEST METHOD Level 1 Marking Level 2 Marking HTI24≥ 9 s HTI24≥ 13 s HEAT TRANSFER-FLAME EN 367 X 1 X 2 HTI24-HTI12≥ 3s f HTI24-HTI12≥ 4s f RHTI24≥ 10 s RHTI24≥ 18 s HEAT TRANSFER-RADIATION EN 6942 X 1 X 2 RHTI24-RHTI12 ≥ 3 s r RHTI24-RHTI12 ≥ 4s r RESISTANCE TO WATER EN 20811 Level 1 < 20 kPa Y1 Level 2 ≥ 20 kPa Y2 PENETRATION WATER VAPOUR EN 31092 Level 1 > 30 m2Pa/W Z1 Level 2 ≤ 30 m2Pa/W Z2 RESISTANCE OUTER LAYERS: HEAT PROTECTIVE FC - FLUOROCARBON FINISHED WATER REPELLENT OUTER LAYERS NOMEX® OUTERSHELL TOUGH, PBI® KEVLAR®, NOMEX® ADVANCE MOISTURE BARRIERS: THE BREATHABLE MOISTURE BARRIERS GIVES PENETRATION RESISTANCE AGAINST TO WATER OR OTHER LIQUIDS. 100% ARAMID OR ARAMID - MELAMIN MIXTURE + PU MEMBRANE HEAT BARRIERS: THE HEAT BARRIERS PROVIDE THERMAL ISOLATION 100% ARAMID OR ARAMID - MELAMIN MIXTURE. INNER LAYER: THE INNER LAYER PROVIDES COMFORT. NOMEX® COMFORT, NOMEX® VISCOSE FYRAL® Series FYRAL® Series garments are professional technical garment that are need to be used by trained individuals. They are used in different fire fighting techniques other than special designed FYRPRO® series. Employee must decide which firefighting garment should be used after the risk analysis in case of fire. FYRAL® series garments are manufactured as per EN 1486:2007 and certified as per 89/686/EEC – PPE. FYRAL® series garments which have this standard are used with self contained breathing apparatus and aims the protection of the user from the heat stress by reflecting radiant heat. For this reason, special aluminized fabric is used in the outer layer which has pre property of reflecting the radiant heat. Garments are formed with 3 or 4 main layers. Moisture Barrier can be added according to area of use. • Outer layer (Fire resistant fabric which is resistant against heat and mechanical effects, water repellent) • Heat Barrier (double or single layered , generally non-woven fire resistant layer) • Inner Liner (quilted on heat barrier, low weight fire resistant fabric) FYRTEX® Series Our company has also been developing Industrial Heat and Flame Protection Garments which are widely used in Industry. These garments are generally produced under the brandname of FYRTEX® in the conformity of European standards such as EN ISO 11612, EN 1149-5 (EN 1149-3 & EN 1149-1). Garments certified against EN 11612 standard, are categorized according to below performance levels. A: EN ISO 15025 - Limited flame spread (from 1 to 2) B: ISO 9151 - Convective heat (from 1 to 3) C: EN ISO 6942 - Radiant heat (from 1 to 4) D: ISO 9185 - Molten Aluminium splash (from 1 to 3) E: ISO 9185 - Molten Iron splash (from 1 to 3) F: ISO 12127 - Contact heat (from 1 to 3) Some of them are specialized for using against particular dangers e.g. Electrical arc Protection (EN 61482-1-2 & EN ISO 11612) , Molten Metal Splash Protection, Wildland Fires, antiflash hoods. Electric arc garments certified against EN 61482 standard, are categorized Class 1 (tested against 4 kA) and Class 2 (tested against 7 kA) . Class 2 is the highest level that can be reached in order to enable protection against electric arc. All of our products in our protective clothing division have been certified as per related harmonized standards, CE marked and certified in accordance with 89 / 686 EEC PPE Directive. FIRE FIGHTING GARMENTS FYRPRO® SERIES GARMENTS FYRPRO® 430-G, FYRPRO® 430 FIRE FIGHTING GARMENTS FYRPRO® 440 FIRE FIGHTING GARMENTS P/N: 13141044 Overall P/N: 13152344 P/N: 13141144 Garment Produced in accordance with EN 469:2005 standard. According to the Personal Protective Equipment Directive 89/686/EEC it has EC Produced in accordance with EN 469:2005 standard. According to Type Examination Certificate. the Personal Protective Equipment Directive 89/686/EEC it has EC Type Examination Certificate. Fyrpro® 440 has CE symbol and wheelmark in accordance with Marine Equipment Directive 96/98/EC-MED. Marked. Marked. Wheelmarked, MED certificated. Xf2, Xr2, Y2, Z2 Xf2, Xr2, Y2, Z2 Layer system Outer layer : PBI® GOLD (58% KEVLAR®, 40% PBI® Layer system 2% Beltron®), rip-stop Moisture barrier : Aramid/Melamin + PU membrane Outer layer : NOMEX® Outershell Tough (75% NOMEX®, Heat barrier : Aramid/Melamin nonwoven 23% KEVLAR® 2% P 140) Inner layer : (50:50)% Aramid/Viscose FR Moisture barrier : FR Knitted Fabric + PU membrane Design : Jacket + Pants, Coveralls Heat barrier : 100% Aramid nonwoven Reflective : 75 mm yellow-grey-yellow Inner layer : (50:50)% Aramid/Viscose FR Zippers : Metal teeth, non-flammable, Design : Jacket + Pants quick release zipper Reflective : 50 mm yellow-grey-yellow Cuff : Metaaramid knitted interlock fabric Zippers : Metal teeth, quick release zipper Pockets : Two covered pocket on each side of jacket Cuff : Metaaramid knitted interlock fabric and radio pocket on left breast Pockets : Two covered pockets on eachside of jacket and radio pocket on left breast. NOMEX® and KEVLAR® are the registered trademarks of DuPont. PBI GOLD® is the registered trademarks of PBI Performance Products, Inc. 4 FIRE FIGHTING GARMENTS FYRPRO® SERIES FIREMAN GARMENTS FYRPRO® 453 FIRE FIGHTING GARMENTS FYRPRO® 510 FIRE FIGHTING GARMENTS P/N : 13112355 P/N : 13118444 FYRPRO® 453 Series Fire Protection Garments are produced FYRPRO® 510 Series Fire Protection Garments are produced according to EN 469: 2005 standard. Our products have been CE according to EN 469:2005 standard. Our products are marked and marked and certified in accordance with 89/686/EEC PPE Directive. certified in accordance with 89/868/EEC Directive. Marked. Marked. Xf2, Xr2, Y2, Z2 Xf2, Xr2, Y2, Z2 Layer System Layer system Outer layer : 75% Metaaramid, 23% Paraaramid, Outer layer : NOMEX® ADVANCE (40% NOMEX®, 2% Antistatic, rip-stop 60% KEVLAR®), rip-stop Moisture barrier : Aramid/Melamin + PU membrane Moisture barrier : SONTARA® FR 89/52. Heat barrier : Aramid/Melamin nonwoven (two layers) Heat barrier : Aramid/Melamin nonwoven Inner layer : 93% Metaaramid + 5% Paraaramid + Inner layer : Aramid/Viscose FR (50:50)% 2% Antistatic fibre Design : Jacket + Pants Design : Jacket + Pants Cuff : Metaaramid knitted interlock fabric Reflective : 50-75 mm red-grey-red Reflective : 75 mm yellow-grey-yellow, flame retardant Zippers : Aramid zipper with metallic teeht,quick release Zippers : Aramid zipper with Brass teeth zipper Pockets : Two covered pockets on each side of jacket Wrist bands : Metaaramid fabric and radio pocket on left breast. Pockets : Radio pocket on the left breast and two covered Lower part of pockets on each side. the trouser leg : Zippers which are openable and closeable. NOMEX®, KEVLAR® and SONTARA® are registered trademarks of DuPont. 5 www.ist.com.tr FIRE FIGHTING GARMENTS FYRPRO® SERIES GARMENTS FYRPRO ® 442 FIRE FIGHTING GARMENTS FYRPRO ® 431-G, FYRPRO ® 431-C FIRE FIGHTING GARMENTS P/N: 13112244 P/N: 13141040 Overall P/N: 13141544 Garment Produced in accordance with EN 469:2005 standard. According to the Personal Protective Equipment Directive 89/686/EEC it has EC Type Produced in accordance with EN 469:2005 standard. According to the Examination Certificate. Personal Protective Equipment Directive 89/686/EEC it has EC Type Examination Certificate. Marked. Marked. Xf2, Xr2, Y2, Z1 Xf2, Xr2, Y2, Z2 Layer system Layer system Outer layer : 75% Metaaramid, 23% Paraaramid, Outer layer : PBI GOLD PLUS® (60% KEVLAR®, 40% PBI®), rip-stop 2% Antistatic Moisture barrier : Aramid/Melamin + PU membrane Moisture barrier : Knitted fabric/PU membrane Heat barrier : Aramid/Melamin nonwoven Heat barrier : 100% Aramid nonwoven Inner layer : (50:50)% Aramid/Viscose FR Inner layer : (50:50)% Aramid/Viscose FR Design : Jacket + Pants, Coverall Design : Jacket + Pants Cuff : Metaaramid knitted interlock fabric Reflective : 50 mm yellow-grey-yellow Reflective : 75 mm yellow-grey-yellow aramid Zippers : Metal teeth, quick release zipper Zippers : Non-flammable, quick release Cuff : Metaaramid knitted interlock fabric Pockets : Two covered pockets on each side of jacket and Pockets : Two covered pocket on each side of jacket and radio pocket on left breast. radio pocket on left breast. PBI GOLD PLUS® is the registered trademarks of PBI Performance Products, Inc. KEVLAR® is registered trademark of DuPont. 6 FIRE FIGHTING GARMENTS FYRPRO® SERIES GARMENTS FYRPRO ® 450-S FIRE FIGHTING GARMENTS P/N: 13172355 Produced in accordance with EN 469:2005 standard. According to the Personal Protective Equipment Directive 89/686/EEC it has EC Type Examination Certificate. Marked. Xf2, Xr2, Y2, Z2 Layer system Outer layer : NOMEX® Outershell Tough (75% NOMEX®, 23% KEVLAR®, 2% P140), rip-stop Moisture barrier : Aramid/Melamin + PU membrane Heat barrier : 100% Aramid nonwoven Inner layer : NOMEX® COMFORT (93% NOMEX®, 5% KEVLAR®, 2% ANTISTATIC) Design : Jacket + Pants Reflective : 50-75 mm red-grey-red Zippers : Non-flammable, quick release Cuff : Metaaramid knitted interlock fabric Pockets : Radio pocket on the left breast and two covered pockets on each side. NOMEX® and KEVLAR® are the registered trademarks of DuPont.
Recommended publications
  • Risk Assessment
    RISK ASSESSMENT INTRODUCTION Industrial plants deal with materials, which are generally hazardous in nature by virtue of their intrinsic chemical properties or their temperature or pressure of operation or a combination of these. Fire, explosion, hazardous release or a combination of these are the hazards associated with industrial plants. These have resulted in the development of more comprehensive, systematic and sophisticated methods of safety engineering such as hazard analysis and risk assessment to improve the integrity, reliability and safety of industrial plants. The primary emphasis in safety engineering is to reduce risk to human life and environment. The broad tools attempt to minimize the chances of accidents occurring. Yet, there always exists, no matter how remote, that small probability of a major accident occurring. If the accident involves highly hazardous materials in sufficiently large quantities, the consequences may be serious to the plant, to surrounding areas and the populations therein. RISK ASSESSMENT AND HAZARD IDENTIFICATION Hazard identification, HAZOP and risk assessment for proposed LPG plant have been carried and risk mitigation measures have been spelled to enhance safety for proposed LPG Plant and same is presented in RRA Report attached to EIA Report Disaster Management Plan for the unlikely event of an emergency is available and same is presented in RRA Report attached to EIA Report. RISK REDUCTION MEASURES Risk Assessment study provides a quantitative technique for assessing the significance of the impact of any facility on its external environment, highlights key areas for greater attention and provides a tool for comparing alternative options. Though, it cannot substitute for close attention to the fundamentals of safety throughout the design process or for design reviews.
    [Show full text]
  • Fire Safety Technologies
    ISSN:0971–4413 A Bimonthly S&T Magazine of DRDO Vol. 23 No. 6, November – December 2015 FIRE SAFETY TECHNOLOGIES DRDO has made outstanding contributions in of the lab provided continuous technology inputs the vital areas of safety management; development for evolving more efficient and practical safety of systems, devices, processes and materials in the practices in the area of fire, explosives and fields of fire, explosives and environment safety for environment safety. Besides providing consultancy defence services and Ministry of Defence (MoD) to government departments, public and civil sector establishments through its concerted R&D efforts. units on explosives/fire/environment safety related Centre for Fire, Explosive and Environment Safety matters, the lab conducts special courses and (CFEES), an establishment of DRDO plays a provides training to personnel of defence services, unique regulatory and advisory role in MoD such inter service organisations, ordnance factories and as safety advice, audit, regulations and compliance other defence undertakings. It also plays a pivotal of Storage and Transport of Explosive Committee role in safety management in DRDO. Risk and (STEC), siting of explosive storages facilities Hazard Analysis (RHA) is mandatory under the and fire advisory. CFEES is also a member of manufacture, storage and import of Hazardous Environment Safety Committee (ESC) for MoD and Chemicals Rules, 1989 for those establishments Ministry of Environment and Forests (MoEF). Apart handling or processing the specified chemicals in from advisory and regulatory duties, the R&D work excess of the stipulated threshold limits. accomplished by the laboratory encompasses wide spectrum of activities like design and development CFEES has carried out RHA and EIA studies for of systems, design of new facilities and processes in more than 30 MoD special projects and installations.
    [Show full text]
  • HALDIA DOCK COMPLEX an ISO-9001: 2008 Organization Dist-Purba Medinipur, West
    KOLKATA PORT TRUST HALDIA DOCK COMPLEX An ISO-9001: 2008 Organization Dist-Purba Medinipur, West. Bengal, India, PIN-721604 Phone: +91-3224-252662 ; M : 9434735407 E-mail: [email protected] No. : SDM(P&E) / 981 / 727 Dated: 06/09/2018 Subject: Budgetary offer for the work “Design, Supply, Fabrication, Erection, Testing & Commissioning and Handing over of Modernized Fire Fighting Facilities as per OISD 156 / NFPA and other good engineering practices at Outer Terminal-II(OT-II) of Haldia Dock Complex Kolkata Port Trust. ” ………………………………………………… Haldia Dock Complex (HDC) is constructing a riverside jetty viz. Outer Terminal –II (OT-II) for handling of LPG with dwt of vessel from 20,000MT to 40,000 MT. HDC would also like to install fire-fighting system as per OISD -156 standard for handling of LPG at their up-coming jetty. Commissioning of such fire fighting system should be carried out at the upcoming riverside jetty viz. Outer Terminal –II (OT-II). Therefore intending Bidders having similar work experience in the Port/Central Govt./State Govt./PSUs/Power Sector are requested to submit budgetary offer with Terms & Conditions based on the Technical Specifications , enclosed herewith marked as ANNEXURE-A, to meet the requirement of OISD-156 guidelines. With Regards, S.Chakrabarty Sr.Dy.Manager(P&E) Haldia Dock Complex ANNEXURE-A TECHNICAL SPECIFICATIONS FOR MATERIALS AND WORKMANSHIP Haldia Dock Complex (HDC) is constructing a riverside jetty viz. Outer Terminal –II (OT-II). HDC would also like to install fire-fighting system as per OISD -156 standard at their up-coming jetty. Commissioning of such fire fighting system should be carried out at the upcoming riverside jetty viz.
    [Show full text]
  • Chapter 1: Additionalstudies (Risk Assessment, Disaster
    EIA / RA STUDY FOR INSTALLATION OF PETROLEUM STORAGE TANKS FOR STORAGE CAPACITY AUGMENTATION AT IOCL PETROLEUM TERMINAL, PHOOS MANDI, BHATINDA, PUNJAB CHAPTER 1: ADDITIONALSTUDIES (RISK ASSESSMENT, DISASTER MANAGEMENT PLAN, WHAT IF ANALYSIS) 1.0 ADDITIONALSTUDIES (RISK ASSESSMENT, DISASTER MANAGEMENT PLAN, WHAT IF ANALYSIS) 1.1 INTRODUCTION Industrial process & activities inherently pose hazards. There may be possible hazards to human beings, flora-fauna, all forms of property and the environment as a whole. Extreme care is essential in handling all of them in various stages of manufacturing viz. processing, treatment etc. The management aims at full preparedness to meet effectively the eventualities resulting from any unfortunate occurrence of fuel hazards/accidents. Hazard analysis involves the identification and quantification of the various hazards (unsafe conditions) that exist in the project site. On the other hand, risk analysis deals with the identification and quantification of risks; the Terminal equipment and personnel are exposed to, due to accident resulting from the hazards present in the Terminal. The main objective of the risk assessment study is that unit is MAH unit as per statutory regulations .We attempt to determine damage due to major hazards having damage potential to life and property and provide a scientific basis to assess safety level of the facility. The secondary objective is to identify major risk in manufacturing process, operation, occupation and provide control through assessment. To prepare on-site, off site, for control of hazards. The concept of risk assessment and its industrial application has been well acclaimed since more than a decade. A variety of major accidents have focused attention on the dangers of risk exposure for human health and environment.
    [Show full text]
  • Annexure 2: Risk Assessment Document
    Annexure 2: Risk Assessment Document. EXPANSION OF LPG & PROPANE, IMPORT AND STORAGE TERMINAL AND ASSOCIATED SHV ENERGY PVT. LTD. HANDLING AND TRANSPORTATION ADDITIONAL STUDIES 7 ADDITIONAL STUDIES 7.1 Public Consultation As this is B2 category project, public consultation is not required. 7.2 Hazard Identification and Consequence Analysis The risk assessment process is intended to identify existing and probable hazards in all operations and work environment, to quantify the hazards and to access the risk levels of those hazards in order to prioritize those that need an immediate attention. 7.2.1 Methodology of Risk Assessment The methodology includes, Hazard identification, Selection of potential loss scenarios, Simulation of release source model on DNV’s PHAST 7.1, Plotting the damage contour on site map These steps undertaken to carry out risk assessment for this project are described in following sections. 7.2.2 Hazard Identification The project description, and other project related data provided by the client have been comprehensively reviewed to identify the hazardous operations. Also the information on the hazardous properties (MSDS) of all the chemicals handled at the site has been reviewed to identify the hazards associated with the same. At present SHV is going to expand an isolated storage facility for LPG. This involves storage of some of LPG at the site which can lead to uncontrolled release of hazardous material causing hazard. On the basis of this, the important hazards that can lead to accident in the proposed project
    [Show full text]
  • Risk Assessment Study Report for Augmentation of Facilities at Crude Oil Terminal at Mundra, Gujarat
    RISK ASSESSMENT STUDY REPORT FOR AUGMENTATION OF FACILITIES AT CRUDE OIL TERMINAL AT MUNDRA, GUJARAT PROJECT PROPONENT HPCL-MITTAL PIPELINES LIMITED (HMPL) PLOT NO.6 (2), OLD PORT ROAD OPPOSITE MUNDRA CSF NEAR SAMUDRA TOWNSHIP MUNDRA, DISTT. KUTCH-370421 GUJARAT MCPL/EMD/TANK/2017-18/02/02 October, 2018 Prepared By MANTEC CONSULTANTS PVT. LTD. (QCI Accredited EIA Consultant at S.No.102 as per List of Accredited consultant Organizations/Rev. 70 /October 2018) (NABET Accredited EIA consultant, MoEF & NABL approved Laboratory) Environment Division, D-36, Sector-6, Noida-201 301, U. P., Ph. 0120-4215000, 0120-4215807 Fax. 0120-4215809, e-mail : [email protected] http://www.mantecconsultants.com RISK ASSESSMENT STUDY FOR AUGMENTATION OF FACILITIES AT CRUDE OIL TERMINAL AT MUNDRA, GUJARAT Table of Contents EXECUTIVE SUMMARY ............................................................................................................................ (I-IX) CHAPTER 1: INTRODUCTION.................................................................................................................. 1 1.1 Introduction ............................................................................................................................. 1 1.2 Need of the Project .................................................................................................................. 1 1.3 Scope of Study ......................................................................................................................... 1 1.4 Execution
    [Show full text]
  • HAZARD IDENTIFICATION • Identify Potentially Hazards That Can Cause
    HAZARD IDENTIFICATION • Identify potentially hazards that can cause loss of human life/injury, loss of properties and deteriorate the environment due to loss of containment. • Identify potential scenarios, which can cause loss of containment and consequent hazards like fire, explosion and toxicity. 7.3 CONSEQUENCE ANALYSIS • Evaluate the magnitude of consequences of different potential hazard scenarios and their effect zones. • Consequence analysis is a measure of potential hazards and is important for taking precautionary measures for risk reduction as well as for preparation of Disaster Management Plan. This report has been prepared by applying the standard techniques of risk assessment and by using DNV, Technica software “Phast Risk Micro (Version 6.7)” and the information provided by IOCL as well as field study. 7.4 GLOSSARY OF TERMS USED IN RISK ASSESSMENT The common terms used in Risk Assessment and Disaster Management are elaborated below: “Risk” is defined as a likelihood of an undesired event (accident, injury or death) occurring within a specified period or under specified circumstances. This may be either a frequency or a probability depending on the circumstances. “Hazard” is defined as a physical situation, which may cause human injury, damage to property or the environment or some combination of these criteria. “Hazardous Substance” means any substance or preparation, which by reason of its chemical or physico-chemical properties or handling is liable to cause harm to human beings, other living creatures, plants, micro-organisms, property or the environment. “Hazardous Process” is defined as any process or activity in relation to an industry, which may cause impairment to the health of the persons engaged or connected therewith or which may result in pollution of the general environment.
    [Show full text]
  • Infrastructure Limited, Mumbai
    RISK ASSESSMENT & DISASTER MANEGEMENT PLAN FOR THE DEVELOPMENT OF ALL-WEATHER MULTI CARGO CAPTIVE JETTY IN A GREENFIELD SITE AT VILLAGE NANDGAON, MAHARASHTRA INFRASTRUCTURE LIMITED, MUMBAI WAPCOS INDIA LIMITED (A GOVT. OF INDIA UNDERTAKING) PLOT No. 76-C, SECTOR 18, GURGAON-122 015, HARYANA INFRASTRUCTURE LIMITED RISK ASSESSMENT & DISASTER MANAGEMENT PLAN FORTHE DEVELOPMENT OF ALL-WEATHER MULTI CARGO CAPTIVE JETTY IN A GREENFIELD SITE AT VILLAGE NANDGAON, MAHARASHTRA WAPCOS INDIA LIMITED (A GOVT. OF INDIA UNDERTAKING) PLOT NO. 76-C, SECTOR 18, GURGAON-122 015, HARYANA RA & DMP Study for All-Weather Multi Cargo Captive Jetty in a Green Field Site at Village Nandgaon, Maharashtra i INFRASTRUCTURE LIMITED CONTENTS RISK ANALYSIS AND DISASTER MANAGEMENT PLAN 1.1 Introduction ................................................................................................................... 1 1.2 Approach to the Disaster Management Plan ................................................................. 2 1.3 General nature of the Hazards ...................................................................................... 4 1.3.1 Vulnerability Profile of the Site with respect to National Disaster............................... 5 1.4 Risks due to Handling of solid bulk/break bulk Hazardous Material ............................... 9 1.5 Risks due to Handling of Liquied Hardous Material ..................................................... 17 1.5.1 Hazardous Material Proposed to be Handled on the Port ...........................................
    [Show full text]
  • Annexure-Risk Assessment
    R E P O R T ON RISK ANALYSIS & DISASTER MANAGEMENT PLAN FOR POL TERMINAL AT ALINAGAR MUGHALSARAI (U.P) OF M/s INDIAN OIL CORPORATION LIMITED Prepared By An ISO 9001:2015, OHSAS 18001:2007 Certified & ISO/IEC 17020:2012 Accredited Co. PROJECTS & DEVELOPMENT INDIA LIMITED (A Govt. of India Undertaking) PO: Sindri, Pin - 828122, Dist: Dhanbad (Jharkhand) NABET Accredited Sl. No. 119; Dated: 5/03/2018 PDIL JOB NO: 9725 MARCH, 2018 9725-RA-MUGHALSARAI 1 PROJECTS & DEVELOPMENT INDIA LTD. DOCUMENT NO. REV SHEET 1 OF 2 RISK ANALYSIS & DISASTER MANAGEMENT PLAN FOR POL TERMINAL AT ALINAGAR MUGHALSARAI (U.P) OF M/S INDIAN OIL CORPORATION LIMITED 0 January, 2018 RA REPORT GB DKC AKS REV DATE PURPOSE PREPARED REVIEWED APPROVED FORM NO. 02-0000-0021 F1 REV 1 All rights reserved 9725-RA-MUGHALSARAI-161 1 RA FOR POL TERMINAL AT MUGHALSARAI, (U.P) OF M/S IOCL DOCUMENT NO. REV SHEET 2 OF 2 C O N T E N T S CHAPTER DESCRIPTION PAGE 1.0 EXECUTIVE SUMMARY 1 - 5 2.0 INTRODUCTION 1-2 3.0 PROJECT DETAILS 1-3 3.0 RISK ANALYSIS 1-27 4.0 DISASTER MANAGEMENT PLAN 1 - 33 ATTACHMENT DESCRIPTION PAGE DRG. NO. 1 LAYOUT PLAN OF POL TERMINAL AT MUGHALSARAI, M/S IOCL 01 DRG. NO. 2 ISO-RISK CONTOUR FOR POL TERMINAL AT MUGHALSARAI, M/S IOCL 01 DRG. NO. 3 F/N CURVE FOR POL TERMINAL AT MUGHALSARAI, M/S IOCL 01 THERMAL RADIATION DISTANCE DUE TO POOL FIRE FOR MS TANK (T- DRG. NO. 4 01 21) ON FIRE THERMAL RADIATION DISTANCE DUE TO POOL FIRE FOR SKO TANK (T DRG.
    [Show full text]
  • Hazmat Suit - Wikipedia, the Free Encyclopedia 11/8/10 8:19 PM
    Hazmat suit - Wikipedia, the free encyclopedia 11/8/10 8:19 PM Hazmat suit From Wikipedia, the free encyclopedia A Hazmat suit is a garment worn as protection from hazardous materials or substances. A Hazmat suit is generally combined with breathing apparatus for protection and may be used by firefighters, emergency personnel responding to toxic spills, researchers, specialists cleaning up contaminated facilities, or workers in toxic environments. It is sometimes confused with, or referred to as, an NBC (Nuclear, Biological, Chemical) suit, which is a military version intended to be usable in combat. US Air Force firefighters in suits with an outer aluminized shell go through a decontamination line during an emergency management Contents exercise. 1 Capabilities 1.1 Overview 1.2 Ratings 1.2.1 In the United States 1.2.2 In Europe 2 Types 2.1 Gas / vapor protection 2.2 Splash protection 3 In fiction 4 See also 5 References Capabilities Overview The United States Department of Homeland Security defines a Hazmat suit as "an overall garment worn to protect people from hazardous materials or substances, including chemicals, biological agents, or radioactive materials."[1] More generally, Hazmat suits may provide protection from: Chemical agents—through the use of appropriate barrier materials like teflon, heavy PVC or rubber and Tyvek Nuclear agents—possibly through radiation shielding in the lining, but more importantly by preventing direct contact with or DEA agents wearing Level B inhalation of radioactive particles or gas hazmat suits. Biological agents—through fully sealed systems (often at overpressure to prevent contamination even if the suit is damaged) Fire/high temperatures—usually by a combination of insulating and reflective materials which reduce or retard the effects The Hazmat suit generally includes breathing air supplies to provide clean, uncontaminated air for the wearer.
    [Show full text]
  • Safety and Fire Protection
    International Safety Guide Chapter 19 for Inland Navigation Tank-barges and Terminals Safety and fire protection Chapter 19 SAFETY AND FIRE PROTECTION This Chapter contains general guidance on safety management at terminals and specific recommendations on the design and operation of fire detection and protection systems. The guidance on fire-fighting equipment in this Chapter should be considered in conjunction with Chapter 5, which addresses fire-fighting theory. 19.1 Safety 19.1.1 Design Considerations The layout and facilities at a terminal will be determined by many factors, including: • Local topography and water depth. • Access to the berth(s) - open sea, river, channel or inlet. • Types of cargo to be handled. • Quantities of cargo to be handled. • Local facilities and infrastructure. • Local environmental conditions and restrictions. • Current and tide. • Local and international regulations (e.g. escape routes, emergency stops). Most of the decisions regarding layout of facilities will have been decided at the initial planning and design stage for the terminal. However, many terminals have developed over time and may be required to handle a greater variety of products, larger quantities of cargoes and larger tankers than were anticipated when the terminal was originally designed. Terminals may also be subjected to reduced throughputs or changing environmental conditions, new standards and/or legislation. All terminals should be subjected to regular review to ensure that the facilities provided remain fit for purpose in the context of the operations being undertaken and current legislation. Such reviews should cover elements listed in the following sections, which will enable the terminal to maintain continuously the necessary level of safety.
    [Show full text]
  • 40540-014: South Asia Subregional Economic Cooperation Road
    Initial Environmental Examination Project No. 40540-014 January 2020 Revised Initial Environmental Examination for Additional Work Scope Under SASEC Road Connectivity Project Improvement of Joydebpur-Chandra-Tangail-Elenga Road (N-4) To a 4-lane Highway This Initial Environmental Examination is a document of the borrower. The views expressed herein do not necessarily represent those of ADB's Board of Directors, Management, or staff, and may be preliminary in nature. In preparing any country program or strategy, financing any project, or by making any designation of or reference to a particular territory or geographic area in this document, the Asian Development Bank does not intend to make any judgments as to the legal or other status of any territory or area. Government of the People’s Republic of Bangladesh Ministry of Road Transport and Bridges Road Transport and Highways Division Roads and Highways Department (RHD) Revised Initial Environmental Examination for Additional Work Scope Under SASEC Road Connectivity Project Improvement of Joydebpur-Chandra-Tangail-Elenga Road (N-4) To a 4-lane Highway Project Implementation Consultants: Kunhwa Engineering & Consulting Co. Ltd. (South Korea) in Joint Venture With Korea Consultants International Co. Ltd. (South Korea) Intercontinental Consultants and Technocrats Pvt. Ltd. (India) in association With Development Design Consultants Ltd. (Bangladesh ) February 2019 List of Abbreviation AAQ Ambient Air Quality AOI Area of Influence APHA American Public Health Association BOD Biological Oxygen
    [Show full text]