Date: October 26, 2018 (revised 11/27/2018) (revised 12/05/2018)

Gino Leonardi

City of Ithaca | Zoning Administrator 108 E. Green St. 3rd Floor Ithaca, NY 14850

Lisa Nicholas

City of Ithaca | Division of Planning and Economic Development

108 E. Green Street, 3rd Floor

Ithaca, N.Y. 14850

Re: Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

(304 Meadow Street, City of Ithaca, NY)

Dear Gino, Lisa and Board of Zoning Appeals and Planning and Development Board members,

We are pleased to be submitting the Maguire Family of Dealerships addition and improvement project to the Ford Dealership located at 504 S Meadow Street, Ithaca, NY. This project will improve the site, exterior appearance and interior design of the building. This improvement is driven by internal programmatic needs and Ford corporate dealership requirements.

Although this project will not be constructed utilizing United Green Building Council (USGBC) LEED Standards we will employ sustainable design principles as we do with all John Snyder Architects (JSA) designed projects. This project will meet or exceed New York State Building / Energy Code and City of Ithaca Green Building Policy requirements.

Our narrative and detailed description of the project is as follows:

Building design:

The project entails additions and renovations to the interior of the building to meet Ford corporate and customer experience requirements. We will also be reorganizing the internal layout to better serve customers and make the internal employee flow more efficient including expansion of second floor offices, new customer bathrooms and new parts and customer waiting areas.

The additions encompass the following:

A. West addition: This includes a service drive through addition to the rear (west side) of the building including the expansion of the existing second floor for additional offices displaced from the first

John Snyder Architects, PLLC | 700 Cascadilla Street ‐ Suite 203 | Ithaca, NY 14850 | P. 607.273.3565

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

floor. This addition replaces an existing canopy (open air) structure currently used for car parking. The first floor will be renovated to include a new service waiting area for customers.

B. East and North Addition: This includes expansion of the showroom end of the building (north and east side) aligning the building with the existing service bay portion of the building currently located on the south side of the building. Also included in this addition is a new entrance to the showroom meeting Ford corporate branding requirements. The east addition will bring the building face approximately six feet closer to Meadow street however given site constraints we will not meet the City of Ithaca zoning requirements for this required front yard setback. A zoning variance is being requested for this deficiency.

C. The exterior appearance: Ford Corporate requirements dictate new metal exterior panels that will encompass all sides of the building differentiating the showroom (north side) from the service side of the building with differing types of metal panels. The showroom addition also includes the new Ford “foil” curved form vestibule. This will transform the exterior appearance of the building making the exterior of this “utilitarian” car dealership into a modern, contemporary car showroom and service center.

Structural Design:

Elwyn and Palmer are the structural engineers for this project. The building additions will be steel framed with new slab / foundation supporting structure. The existing steel frame will be modified as needed for new connections. The existing west “canopy” addition will be completely removed with the existing structural waffle slab left in place for the new west addition to be erected partially over top.

Mechanical System Design:

The JSA internal engineering team is working on the mechanical system design. This team is led by sustainably focused and LEED accredited mechanical engineers. The design goal of the new mechanical system is to design an energy efficient system replacing current inefficient systems. Our engineers are currently working on the new system design.

Electrical / Data System Design:

The JSA internal engineering team is working on the electrical system design. This new design provides for the relocation of internal outlet and devices and provision for new outlets and data outlets to meet requirements established Ford Corporate requirements. No new service utility company upgrades are required. Our engineers are currently working on the new system design.

Plumbing System Design:

The JSA internal engineering team is working engineering team on the plumbing system modifications. The internal layout requires removal of existing customer bathrooms and provision of new bathrooms at the rear (west addition) of the building. All new plumbing will connect to existing supply and waste lines currently in place inside the building. No City of Ithaca or connections to Meadow Street are needed for this project. Our engineers are currently working on the new system design.

Page 2 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

Site / Civil Design:

Our team is working with the Saratoga Associates on the site and civil engineering portion of the building. The disturbance for this project is less than an acre (refer to attached drawings). We are planning on providing a new parking configuration and striping layout to portions of the site along with a new inside the lot to the north side of the building. This sidewalk will provide a new walk path for customers to view cars and connecting the service area of the building for the many customers who walk to the site to / from Wegmans. We are currently showing a total of +/‐311 total parking spaces for customer, service parking, employee and display car parking. Parking quantity is driven by Ford Corporate requirements. We will employ all protections required for existing storm water during construction as dictated by New York State Department of Environmental Conservation.

A portion of the site is located within the 100‐year flood plain with the service drive bay addition located within this area. We have met with the City of Ithaca Building Department and we will meet ASCE 24 Flood Resistant Design and Construction requirements for this portion of the building inside the flood plain.

Landscape Architecture:

Our team is working with the Saratoga Associates on the landscape architecture design for the project. We will be providing an improvement over the existing site conditions with the provision of new tree planting islands within our work areas and new islands within the current parking lot. Existing trees and plantings within our construction zone as required by City of Ithaca requirements. We have revised our site plan and planting plan. The landscape design will be vastly improved and meet minimum landscape requirements dictated by City of Ithaca (12%).

Schedule:

Our team is working with Ford corporate to meet established deadlines necessary for this project. Because of these aggressive deadlines we will need to work collaboratively with the City of Ithaca, Planning Board and Board of Zoning Appeals on the building and site design components of this building. Unfortunately, these deadlines are strict, and we have little room for extension.

Our current schedule is as follows:

A. Ford final design acceptance is currently underway, and we are expecting final approvals in January 2019. B. After Ford corporate approvals we will be issuing drawings for invited contractor bidding. We are expecting to send this out no later than February 2019. C. We desire to seek a building permit in early spring (March) 2019. D. Construction must be complete and final occupancy by September 2019.

Given these required deadlines and the fact the Board of Zoning Appeals is not having a December 2018 (and a January meeting) we will be seeking guidance from the City of Ithaca in order to dovetail all variance and site plan approvals required in order for this project to proceed and meet required internal schedules.

Page 3 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

Conclusion:

The renovations and improvements to this site will change and improve the exterior and site design of this site creating a modern iconic building we will all be proud of. These improvements will require a collaborative approach and we are open and willing to work closely together with the City to achieve approvals given the aggressive schedule required for this project.

Thank you for your time reviewing our application and zoning appeals. We look forward to working with the City on this important project. Please feel free to reach out with any questions or concerns and we look forward to meeting with you.

Sincerely,

John Snyder AIA, NCIDQ, LEED AP President and Design Principal

Attachments:  SPR Application  Owner Authorization  NYS FEAF – Part 1  Zoning Analysis  Area Chart  Drawings o Context Map – Prepared by John Snyder Architects o Zoning Map – Prepared by John Snyder Architects o Survey – Prepared by T.G. Miller, P.C. Engineers and Surveyors o Existing Conditions Plan – Prepared by Saratoga Associates (revised 12/5/2018) o Site Demolition & Erosion Control Plan – Prepared by Saratoga Associates (revised 12/5/2018) o Layout & Materials Plan – Prepared by Saratoga Associates (revised 12/5/2018) o Grading & Drainage Plan – Prepared by Saratoga Associates (revised 12/5/2018) o Planting Plan – Prepared by Saratoga Associates (revised 12/5/2018) o Site Details – Prepared by Saratoga Associates (revised 12/5/2018) o Rendered Site Plan – Prepared by Saratoga Associates (revised 12/5/2018) o Rendered Elevations – Prepared by John Snyder Architects (revised 12/5/2018) o Perspective 1 – Prepared by John Snyder Architects (revised 12/5/2018) o Perspective 2 – Prepared by John Snyder Architects o Perspective 3 – Prepared by John Snyder Architects o Perspective 4 – Prepared by John Snyder Architects o Attachment A – Response to Southwest Planning Guidelines o Attachment B – Response to Tompkins County Recommendations for New Construction o Material Board Sample (submitted 12/5/2018)

Page 4 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

Attachment A: Building Design as it relates to the Southwest Planning Guidelines

A. Primary exterior materials for commercial buildings are limited to masonry, including , stone, and block on all elevations;  Buildings should have at least two masonry types or colors used on its primary facade;  The base of buildings should include a "watercourse" 18" in height of concrete or masonry on all facades;

Response: The existing building is a rigid frame building originally constructed in 1983 with an addition constructed in 1999.

 We will be installing a 4’‐0” tall masonry watertable on portions of the new addition on the North and West Façade.  The metal siding on the service bay area of the building will be replaced with new metal siding. Given the way this building was constructed it would be very difficult to install a masonry watertable on this portion of the building.  The East and portions of the North elevations will be new facades matching Ford branding requirements.

B. Masonry pilasters and/or bays should occur every 40' horizontally and 20' vertically. Projections should be at least 3". Masonry projections should occur on all facades.

Response: Given the existing building constraints and the Ford branding requirements Masonry pilasters are not being implemented however we have provided additional windows as a mitigation to enliven the rear façade and a green wall as described below.

C. Primary building entrances should be recessed for a full door swing or not less than 3 '‐0"; Response: We meet this requirement our front door inset is greater than 3’‐0”.

 Windows, awnings and arcades should not occupy less than 35% of the primary building facades with frontage on a street; i. West Elevation: Facing Wegmans – approximately 4,200 sf of wall surface with approximately 13% windows (includes doors). ii. East Elevation: Facing Meadow Street – approximately 4,164 sf of wall surface with approximately 22% windows (includes doors). iii. North Elevation: Facing Cecil Malone Drive ‐ Response: approximately 3,690 sf with approximately 29% windows. (includes doors). iv. South Elevation: Work on the building face will be the refurbishment (or more likely replacement) of the existing service bay overhead doors and exterior siding.

Response: We meet this guideline.

Page 5 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

D. The design of rear elevations of all buildings should be compatible with materials used on other elevations. Response: We meet this guideline.

 This includes the 18" concrete or masonry "watercourse" and masonry pilasters and/or bays occurring every 40' horizontally and 20' vertically. Response: See Response to Item A and Item B above.

 Compliance with this may be mitigated using vegetation. Response: We are proposing areas of green wall construction on the East and West Elevations totaling approximately 1000 sf.

E. Roof‐mounted equipment and mechanicals shall not be visible from any ground angle, and should be an integral part of overall architectural design with regard to form, materials and color. Penthouse structures should be used when the roof is clearly in view from the gorge trail of Buttermilk Falls State Park.

Response: We will meet this guideline.

Page 6 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

Attachment B: Tompkins County Recommendations for New Construction:

ENERGY STAR products include a wide range of equipment and appliances that are independently certified to save energy without sacrificing features or functionality. Water saving fixtures can reduce energy needed for hot water.

Recommendations:

o Require that water fixtures meet EPA’s Water Sense requirements.

o Require that permanent appliances (apartment refrigerators, restaurant cooking equipment, etc.) be ENERGY STAR rated.

Response: We will meet this recommendation.

3) Recent advances in heat pump design have reduced installation costs and made them more cost‐ effective than electric resistance heat, propane, and oil, and close in life cycle costs to natural gas. Use of electric heat pumps allows elimination of fossil fuels as they can be powered by renewable energy sources such as solar photovoltaic.

Recommendations:

o Utilize electrically‐powered heat pump systems (ground or air source heat pumps); avoid boiler‐assisted heat pump systems, avoid systems that burn fossil fuels.

o Utilize air source heat pump hot water heaters. Response: This project involves the renovation and replacement of existing systems we are unclear to what extent the existing systems will remain or whether they will be replaced at this point. Areas such as the service bay area will likely require modification of existing gas fired units. Our engineering team is currently evaluating the existing MEP systems and providing recommendations to the Owner.

4) The state has a goal that 50% of NYS electricity will be generated by renewables (solar, wind, hydropower, biomass) by the year 2030.

Recommendations:

o Design roofs to be “solar receptive”: Maximize area available for solar collection systems. For pitched roofs, place roof‐mounted components (plumbing vents, exhaust fans, etc.) on north‐ facing roof surfaces, to keep south‐facing surfaces available for solar collection systems. Orient one roof surface to the south, plus/minus 30 degrees, to maximize potential for solar energy.

Response: This project is a renovation of the existing building. The original building rigid frame building was not designed for the increased load of solar panels systems. An optimum location for solar panels would likely occur on the existing service bay structure. This would likely require additional structural investigation and possibly a separate structural “dunnage

Page 7 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

frame” system above the roof to support the load of solar panels. The new additions will be designed with this recommendation in mind.

o Maximize solar collection systems on available roof areas, and consider using high‐ production solar panels to maximize solar production for a given roof area, especially for medium‐rise and high‐rise buildings.

Page 8 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

4) Energy efficient building design begins with the building envelope ‐‐ the walls, windows, foundation and roof.

Recommendations:

o Design to window‐to‐wall ratio less than 25% (the new energy code requires 30% or less). Keep large windows on south‐facing surfaces and important facades, minimize windows on north‐facing surfaces and in spaces which see low occupancy (stairwells, corridors, utility rooms, etc.).

o Avoid unusually complex building shapes.

o Use 20% more insulation R‐value than required by the energy code.

o Use best practices for minimizing infiltration and stack effect, and require inspection/commissioning of these elements: vestibules at entrance doors, air sealing around window and door frames, sealing at exterior wall/floor junctions, and guarded blower door testing of individual spaces or entire building floors.

Response: The additions provided to this building will meet or exceed The Energy Code of New York State requirements. We will utilize continuous insulation wall systems for the exterior metal panel wall. The JSA internal construction administration team will be engaged during construction to ensure successful implementation, inspection and commissioning of the contract documents.

We recommend that all applicants for new construction of greater than 20 units also address whether they are intending to follow the recommendations under each of these three added elements.

5) Lighting controls and high‐efficiency lighting technology (such as LED or induction) offer significant benefits including greatly reduced energy use and cost, sophisticated controls, simplified maintenance and longer life.

Recommendations:

o Perform lighting design on a space‐by‐space basis, using the space‐by‐space lighting power density method (not the whole‐building method). Use LED lighting where possible. Design to lighting power density of 15% less than required by the energy code.

o Require occupancy sensors where possible, for both indoor and outdoor lighting. Require short off‐delay (1 minute or less), and commissioning of lighting controls.

Response: The additions provided to this building will meet or exceed The Energy Code of New York State requirements and we will be utilizing LED lighting and control systems at new installations.

6) High‐efficiency heating and cooling systems cost incrementally more than standard‐ efficiency but have a positive payback over their useful life. Page 9 of 11

Maguire Family of Dealerships ‐ Ford Dealership Additions and Improvements

Recommendations:

o Select high‐efficiency heating and cooling plants with rated efficiencies at least 15% higher than required by the energy code.

o Select high‐efficiency domestic hot water (DHW) plants with rated efficiencies at least 15% higher than required by the energy code.

o Avoid placing heating and cooling distribution systems in unheated spaces, such as attics, basements, etc. Give preference to systems that have efficient distribution systems and low distribution losses (for example, room‐by‐room fan coils).

Response: Our engineering team is currently evaluating the existing MEP systems and providing recommendations to the Owner. We always strive to design high‐efficiency, hot water (DHW), heating and cooling systems. We are planning on locating heating and cooling systems in easy to access ”heated” spaces.

o Use energy recovery ventilation systems in air‐conditioned buildings, and heat recovery ventilation systems in buildings that do not have air conditioning. Design ventilation systems separate from heating and cooling systems.

Response: Our engineering team is currently evaluating the existing MEP systems and providing recommendations to the Owner. We always strive to utilize heat recovery ventilation systems wherever possible.

o Assess ductwork for heating, cooling and ventilation. If leakage greater than 10% seal chases and shafts with aerosol duct sealing process.

Response: Our engineering team is currently evaluating the existing MEP systems and providing recommendations to the Owner. Existing ductwork will not be reused in the North side of the building with provisions for new efficient ductwork.

o Select heating/cooling systems that allow thermal zoning on a space‐by‐space basis. Response: Our engineering team is currently evaluating the existing MEP systems and providing recommendations to the Owner. We always strive to utilize thermal zoning of spaces wherever feasible and possible.

7) Whole building energy models can allow you to dramatically reduce energy costs, reduce carbon emissions and even reduce some construction costs.

Recommendation: o Employ whole building energy modeling to optimize building energy performance. Response: The additions provided to this building will meet or exceed The Energy Code of New York State requirements

Page 10 of 11

Rendered Site Plan Scale: 1” = 30’-0”

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Existing Conditions Plan Scale: Adjusted to 1” = 40’-0”

1 2 3 4 5 6 7 8 9 10

700 Cascadilla St Suite 203 Ithaca, NY 14850

P: 607.273.3565

www.js-architects.com

H

1.7'± W W W W W 386.0

388.5 1.0'±

384.5 30.0'±

384.5 3.8'±

113.4'± G 385.0 384.5

385.0

F

385.0

385.0

385.5

DRAWINGS ALTERATION NOTICE: It is a violation of Section 69.5b of the New York State Education Department for any person, unless acting 385.5 under the direction of the licensed architect, to alter this item in any way. If an item 386.5 bearing the seal of the architect is altered the architect shall affix their seal E 386.0 and the notation "altered by" 385.5 followed by the architect's signature, date of alteration, and a specific description of the alteration. 385.5 COPYRIGHT: All production and intellectual

44.3'± property rights reserved. © Copyright 2018 John Snyder Architects,

PLLC 385.5

Addendum Schedule

73.3'± 386.0

386.0

386.0

386.5 TR 386.0 387.0

388.5 D

387.0 386.5 W

TR

TR

TR TR TR

C Maguire Ford - LEGEND: NOTES: Lincoln 1.) HORIZONTAL DATUM OF MAPPING IS APPROXIMATE NAD 83 AND VERTICAL DATUM IS OVERHEAD WIRES APPROXIMATE NGVD29. SANITARY SEWER MAIN WATER MAIN 2.) UNDERGROUND UTILITIES HAVE BEEN LOCATED FROM AVAILABLE RECORDS, FIELD LOCATIONS OF ABOVE GROUND STRUCTURES AND ANY MARKINGS PROVIDED BY THE UTILITY GAS MAIN AUTHORITY. THEREFORE, THESE LOCATIONS MUST BE CONSIDERED APPROXIMATE. THERE MAY STORM SEWER MAIN BE OTHER UNDERGROUND UTILITIES AND/OR STRUCTURES, THE LOCATION AND EXISTENCE OF WHICH IS NOT PRESENTLY KNOWN. LOCATIONS, SIZES AND MATERIALS OF UNDERGROUND UNDERGROUND TELEPHONE UTILITIES ARE BASED ON BEST AVAILABLE EVIDENCE AS NOTED ABOVE. VERIFY ALL UTILITIES UNDERGROUND ELECTRIC PRIOR TO DESIGN OR CONSTRUCTION.

UNDERGROUND TELECOMMUNICATIONS 3.) IN THE EVENT THAT THERE IS A DISCREPANCY BETWEEN THE CONTENTS OF THE SIGNED AND SEALED HARD COPY DRAWING AND THE CORRESPONDING DIGITAL DRAWING FILE, THE HARD EXISTING DITCH COPY WITH AN ORIGINAL STAMP AND SIGNATURE SHALL BE THE CONTROLLING DOCUMENT. PROPERTY LINE B MAP REFERENCES; MANHOLE 1.)"UFAIR REALTY CORPORATION..." DATED 2/2/1983 BY GEORGE CATCH BASIN SCHLECHT. DOWN SPOUT 2.)"SURVEY MAP No. 504 SOUTH MEADOW STREET..." DATED 8/25/2016 BY 504 S Meadow St. WATER VALVE T.G. MILLER P.C. Ithaca, NY 14850 FIRE HYDRANT NOTE: CLEANOUT THIS SURVEY MAP PREPARED WITHOUT BENEFIT OF AN ABSTRACT OF TITLE PROVIDED, SUBJECT TO Site Plan Review GAS VALVE ANY STATE OF FACT THAT AN UPDATED ABSTRACT OF TITLE MAY SHOW. UTILITY POLE GUY WIRE 12/05/2018 LIGHT POLE

DECIDUOUS TREE Existing Conditions Plan SHRUB PROJ # 1905A SIGN ENTRANCE ELEVATION L100 TELEPHONE PEDESTAL A IRON PIN FOUND CALCULATED POINT

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Site Demolition and Erosion Control Plan Scale: Adjusted to 1” = 40’-0”

1 2 3 4 5 6 7 8 9 10

700 Cascadilla St Suite 203 Ithaca, NY 14850

P: 607.273.3565

1.7'± W W W W www.js-architects.com W 386.0

388.5 1.0'±

H

SAWCUT RELOCATE

384.5 30.0'± SAPLINGS TO HERE REMOVE ASPHALT PAVEMENT AND SUBBASE

384.5 3.8'±

113.4'± 385.0 REMOVE ASPHALT 384.5 PAVEMENT AND REMOVE ASPHALT SUBBASE SAWCUT PAVEMENT AND

385.0 REMOVE ASPHALT SUBBASE PAVEMENT AND

SAWCUT SAWCUT SUBBASE SAWCUT AROUND SEDIMENT CONTROL FENCE REMOVE RR TIE 1 REMOVE ASPHALT WALL AND L600 PAVEMENT AND SAW CUT AND TREES REMOVE RR TIE SUBBASE CLEAR SAWCUT SAWCUT WALL (80LF) DRAINAGE REMOVE RR TIE REMOVE RR TIE G STRUCTURE REMOVE RR TIE WALL AND TREES WALL AND TREES WALL AND TREES SAWCUT INLET

SAWCUT 2 REMOVE ASPHALT PROTECTION PAVEMENT AND L600 SUBBASE CLEAR DRAINAGE RELOCATE REMOVE STRUCTURE REMOVE SAPLING STEEL PIERS SAWCUT EXTERIOR WALL CLEAR DRAINAGE STRUCTURE INLET PROTECTION 2 REMOVE ASPHALT LIGHT POLE REMOVE ROOF L600 REMOVE CONCRETE PAVEMENT AND TO REMAIN STRUCTURE PAVEMENT AND SUBBASE SUBBASE 385.0 RELOCATE LIGHT POLE REMOVE

385.0 CONCRETE WALKS

385.5 F RELOCATE SAPLING

385.5 STRIP TOPSOIL, REMOVE 386.5 REMOVE CONCRETE VEGETATION SAWCUT

WALKS

386.0 385.5 RELOCATE DRAWINGS ALTERATION SIGN NOTICE: RELOCATE It is a violation of Section SAPLING LIGHT POLE 69.5b of the New York State REMOVE ASPHALT TO REMAIN 385.5 Education Department for PAVEMENT AND any person, unless acting SUBBASE under the direction of the 44.3'± licensed architect, to alter this RELOCATE REMOVE item in any way. If an item SIGN CONCRETE bearing the seal of the architect is altered the

385.5 WALKS REMOVE OVERHANG AND PORTION architect shall affix their seal E RELOCATE RELOCATE OF BLDG (SEE ARCH. DWGS.) SIGN and the notation "altered by" SIGNS (2) followed by the architect's REMOVE RR signature, date of alteration, 73.3'± TIE WALL and a specific description of the alteration.

386.0 SAWCUT STRIP CLEAR 386.0 CLEAR COPYRIGHT: TOPSOIL, DRAINAGE All production and intellectual REMOVE RR TIE SAWCUT 386.0 REMOVE DRAINAGE SAWCUT WALL (65LF) STRUCTURE property rights reserved.

STRUCTURE TR SHRUBS 386.5 © Copyright 2018 386.0 REMOVE RR TIE 387.0 John Snyder Architects, WALL (20LF) REMOVE ASPHALT REMOVE ASPHALT PLLC RELOCATE PAVEMENT AND 388.5 RELOCATE SAWCUT RELOCATE RELOCATE RELOCATE SAPLING SUBBASE

SAPLING 387.0 SAPLING SAPLING SAPLING Addendum Schedule 386.5 W

TR

TR TR RELOCATE TR TR SAPLING

REMOVE ASPHALT REMOVE RR TIE PAVEMENT AND WALL (20LF) D SUBBASE

C

DEMOLITION AND EROSION CONTROL LEGEND DEMOLITION NOTES: EROSION CONTROL NOTES: CONSTRUCTION SEQUENCING NOTES: Maguire

1. PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL 1. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES 1. CONTRACTOR TO STAKE OUT ALL NEW WORK IN THE FIELD. Ford - VERIFY THE LOCATIONS OF ALL UNDERGROUND UTILITIES. SHALL BE INSTALLED IN ACCORDANCE WITH NEW YORK REMOVE TREE OR OBJECT IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO UTILIZE STATE STANDARDS AND SPECIFICATIONS FOR EROSION 2. INSTALL SEDIMENT CONTROL FENCE AND INLET Lincoln A LOCATING SERVICE TO VERIFY UNDERGROUND UTILITY AND SEDIMENT CONTROL, AUGUST 2005 PROTECTION AT LOCATIONS SHOWN ON THE PLANS. LOCATIONS. 2. CONSTRUCTION SHALL BE SEQUENCED IN ACCORDANCE 3. AS WORK PROGRESSES, DISTURBED AREAS SHALL BE 2. THE CONTRACTOR SHALL EXERCISE CARE DURING ALL WITH THE CONSTRUCTION SEQUENCE NOTES BELOW. STABILIZED AS SOON AS POSSIBLE AFTER CONSTRUCTION REMOVAL OPERATIONS TO ENSURE THE PROTECTION OF HAS BEEN COMPLETED IN THE AREA. EXISTING FACILITIES TO REMAIN. DAMAGED FACILITIES REMOVE ASPHALT PAVEMENT 3. PAVED ROADWAYS SHALL BE KEPT CLEAN AT ALL TIMES. INTENDED TO REMAIN SHALL BE REPAIRED AT THE 4. AFTER ALL DISTURBED AREAS HAVE BEEN STABILIZED AND AND SUBBASE CONTRACTOR'S EXPENSE. 4. THE SITE SHALL AT ALL TIMES BE GRADED AND THE FINAL INSPECTION HAS BEEN PERFORMED BY THE MAINTAINED SUCH THAT ALL SEDIMENT LADEN OWNER'S REPRESENTATIVE, REMOVE ALL REMAINING 3. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE STORMWATER RUNOFF IS DIVERTED TO SOIL EROSION AND TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES. REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL SEDIMENT CONTROL FACILITIES. REMOVE CONCRETE PAVEMENT MANNER. AND SUBBASE 5. DUST CONTROL - WATER SHALL BE APPLIED BY SPRINKLER 5. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER'S OR WATER TRUCK DURING GRADING OPERATIONS TO REPRESENTATIVE ALL DEMOLITION ITEMS INDICATED TO BE MINIMIZE SEDIMENT TRANSPORT AND MAINTAIN B SALVAGED. DELIVER SALVAGED ITEMS TO A STORAGE AREA SAWCUT PAVEMENT ACCEPTABLE AIR QUALITY CONDITIONS. REPETITIVE DESIGNATED BY THE OWNER'S REPRESENTATIVE. TREATMENTS SHALL BE DONE AS NEEDED UNTIL GRADES 1 ARE STABILIZED. SEDIMENT CONTROL FENCE 6. THE CONTRACTOR SHALL REMOVE TREES AS INDICATED, L600 504 S Meadow St. PROTECT TREES TO REMAIN FROM DAMAGE. 6. THE CONTRACTOR SHALL INSPECT THE EFFECTIVENESS Ithaca, NY 2 AND CONDITION OF EROSION CONTROL DEVICES DURING 14850 INLET PROTECTION 7. NYSDEC SHALL BE CONTACTED IF ANY CONTAMINATED L600 STORM EVENTS AND REPAIR OR REPLACE DAMAGED SOILS ARE ENCOUNTERED ON SITE. EROSION CONTROL DEVICES IMMEDIATELY. Site Plan Review 7. THE CONTRACTOR SHALL BE PREPARED TO IMPLEMENT INTERIM DRAINAGE CONTROLS AND EROSION CONTROL MEASURES AS MAY BE NECESSARY DURING THE COURSE OF CONSTRUCTION TO PREVENT SEDIMENT LADEN RUNOFF FROM LEAVING THE CONSTRUCTION SITE. 12/05/2018

8. THE CONTRACTOR SHALL MAKE AVAILABLE ONSITE ALL Site Demolition EQUIPMENT, MATERIALS AND LABOR NECESSARY TO EFFECT and Erosion EMERGENCY EROSION CONTROL AND DRAINAGE Control Plan IMPROVEMENTS AS SOON AS PRACTICAL. PROJ # 1905A 9. ALL DISTURBED SOILS SHALL BE PERMANENTLY STABILIZED WITH PAVEMENTS, PLANTINGS AND LAWN AREAS. L200 A

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Layout & Materials Plan Scale: Adjusted to 1” = 40’-0”

1 2 3 4 5 6 7 8 9 10

700 Cascadilla St Suite 203 Ithaca, NY 14850

P: 607.273.3565

www.js-architects.com

H

CONCRETE EXISTING STAIRWAY RETAINING WALL PLANTER SERVICE PARKING (8.5'X16') DISPLAY PARKING (8.5'X18') 22 60' ROW LINE 28

SEAL COAT AND 17' WIDE AISLE 17' WIDE AISLE STRIPE EXISTING ONE WAY ONE WAY SEAL COAT AND ASPHALT STRIPE EXISTING ASPHALT 8 R=10' 40 DISPLAY PARKING

(8.5'X18') (8.5'X18') DISPLAY PARKING

G 7 SAWCUT

SAWCUT (8.5'X18')

DISPLAY PARKING SERVICE PARKING 20 (8.5'X18') DISPLAY PARKING 22 (8.5'X18') R=5' SAWCUT EXISTING RR TIE WALL R=3' 8' HGT. CMU WALL EXISTING CONCRETEEXISTING WALK DUMPSTER ENCLOSURE SEAL COAT AND R=5' STRIPE EXISTING 20' WIDE AISLE 22' WIDE AISLE 20' WIDE AISLE ASPHALT

TIRES SAWCUT SAWCUT SAWCUT EMPLOYEE PARKING 24' R=10' (9'X18') R=5' R=5' 2 ASPHALT ASPHALT PAVEMENT CONCRETE PAVEMENT ASPHALT PAVEMENT- 5 5 5 LAWN L600 PAVEMENT L600 PEDESTRIAN L600 6'TC EMPLOYEE PARKING SERVICE DRIVE THRU 3 R=5' 2 (9'X18') L600 DISPLAY PARKING (8.5'X18') SAWCUT R=5'

DUMPSTERS 10

LAWN R=5' R=5' F HC PARTS ASPHALT RECEIVING PARKING 5 L600 LAYOUT RELOCATED LP PAVEMENT 8 R=5' BODY SHOP L600 11 HC LOUNGE SEAL COAT AND L600 SIGN 5' WIDE CONCRETE ASPHALT STRIPE EXISTING PAVEMENT-PEDESTRIAN PAVEMENT ASPHALT 3 5'X5' COLLAR 5 L600 CONCRETE L600 PAVEMENT-VEHICULAR

LAWN PARTS SAWCUT 17 DRAWINGS ALTERATION NOTICE: (8.5'X18') It is a violation of Section 18 LINCOLN SHOWROOM 20 69.5b of the New York State DISPLAY PARKING (8.5'X18') Education Department for SERVICE A SERVICE B

(8.5'X18') any person, unless acting 20' WIDE AISLE DISPLAY PARKING under the direction of the 12 22' WIDE AISLE 26' WIDE AISLE WIDE 26' 28 licensed architect, to alter this

SERVICE PARKING (9'X18') item in any way. If an item (8.5'X18') bearing the seal of the

architect is altered the DISPLAY PARKING DISPLAY CUSTOMER PARKING CUSTOMER CONCRETE architect shall affix their seal E CONCRETE 6 CURB (TYP.) and the notation "altered by" FORD SHOWROOM WELCOME POD CURB (TYP.) L600 followed by the architect's 6 signature, date of alteration, L600 EXISTING CONCRETE WALK LP and a specific description of the alteration. ASPHALT PAVEMENT COPYRIGHT: SEAL COAT AND 5 All production and intellectual L600 STRIPE EXISTING property rights reserved. PLANT BED VEST. ASPHALT © Copyright 2018 John Snyder Architects, 6'TC BOLLARDs PLLC ENTRY TOWER CONCRETE 5 ASPHALT BIKE EJ PAVEMENT-PEDESTRIAN 11 RACK LAWN ASPHALT 5 Addendum Schedule SERVICE PARKING PAVEMENT 3 PAVEMENT L600 CUSTOMER PARKING (9'X18') 5 L600 L600 (9'X18') R=4' R=2' R=5' R=10' R=4' 6'TC 5'FC 6'TC SAWCUT SEAL COAT AND 7 SAWCUT CONCRETE ADA RAMP 5' WIDE CONCRETE 4 STRIPE EXISTING L600 CONCRETE PAVEMENT-VEHICULAR 22' WIDE AISLE PAVEMENT-VEHICULAR 22' WIDE AISLE L600 ASPHALT PAVEMENT-VEHICULAR 4 4 SAWCUT L600 5 RAISED ASPHALT PAVEMENT L600 RAMP RAMP L600 DISPLAY

D SAWCUT DISPLAY PARKING SAWCUT DISPLAY PARKING 3 R=5' R=5' (8.5'X18') (8.5'X18') STONE WALLDISPLAY 3 FORD LINCOLN 2 15 13 SIGN VEHICLE SIGN DISPLAY STONE WALL

LAWN TR R=5' R=5'

CONCRETE 6 EXISTING CONCRETE WALK LAWN CURB (TYP.) L600 LAWN LAWN

C

LAYOUT NOTES Maguire LAYOUT LEGEND PARKING TABLE 1. PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL UNDERGROUND UTILITIES. Ford - 5 VEHICLE DISPLAY 214 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO UTILIZE ASPHALT PAVEMENT L600 EMPLOYEE PARKING 4 A LOCATING SERVICE TO VERIFY UNDERGROUND UTILITY Lincoln CUSTOMER PARKING 22 LOCATIONS. CONCRETE PAVEMENT WITH HC CUSTOMER PARKING 1 3 4 EXPANSION JOINTS AND SERVICE PARKING 67 2. THE CONTRACTOR SHALL STAKE OUT ALL WORK IN THE L600 L600 SCORE JOINTS FIELD PRIOR TO COMMENCING CONSTRUCTION AND NOTIFY THE OWNERS REPRESENTATIVE OF ANY DISCREPANCIES. 6 CONCRETE CURB TOTAL PARKING 308 L600 3. ALL DIMENSIONS SHALL BE FROM THE FACE OF EDGING, FC FLUSH CURB , OR WALLS UNLESS OTHERWISE NOTED. TC 6' TRANSITION CURB

11 HC SIGNAGE 4. ALL NEW PAVEMENTS AND CURBS SHALL MEET EXISTING L600 PAVEMENTS AND CURBS WITH A SMOOTH TRANSITION AND FLUSH JOINT. 7 ADA RAMP L600 5. THE CONTRACTOR SHALL PROVIDE A 1.5% CROSS SLOPE B ON ALL CONCRETE WALKS CONFORMING TO ADA REQUIREMENTS.

6. THE CONTRACTOR SHALL PROVIDE WARNING CONES AND BARRICADES AS REQUIRED TO PROTECT THE PUBLIC FROM 504 S Meadow St. CONSTRUCTION OPERATIONS. Ithaca, NY 14850 7. SUCCESSFUL LOW BIDDER WILL BE PROVIDED A CAD FILE FOR LAYOUT PURPOSES. Site Plan Review

12/05/2018 LAYOUT AND MATERIALS PLAN PROJ # 1905A L300 A

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Grading & Drainage Plan Scale: Adjusted to 1” = 40’-0”

1 2 3 4 5 6 7 8 9 10

700 Cascadilla St Suite 203 Ithaca, NY 14850

P: 607.273.3565

www.js-architects.com

H 1.7'±

386.0

388.5 1.0'±

384.5 30.0'±

TC384.81 TC385.37 BC384.31 384.5 BC384.87 +

+ 3.8'±

113.4'± G 385.0 384.5

385.0

+ TC385.25 TC385.22 BC384.75 + BC384.72 + TC385.20 BC384.70 384.90 384.75 BS 384.75 SAWCUT 384.55 384.74 +384.80 + + 384.80 + + + + + 384.54 385.00 + + TS 384.90 386.30 TC385.46 + 385 386.50+ 385.5 BC384.96 + 386.50 385 TC385.10 + + TC386.02 BC384.60 TC385.20 + + BC386.00 385.5 SERVICE DRIVE THRU 386 386 TC385.70 BC384.70 BC385.20 + 386.50 + + + 386.50 385.10 6" HDPE RAISE RIM 385 TO 385.00 386.20 386.50 CB#2 386.50 + 6" HDPE TC385.80 + RIM 384.70 + CONNECT BC385.30 385 + TC385.60 PARTS TO CB INV. + CB#1 INV 383.20 BC385.10 RECEIVING F 382.80 RIM 384.90 + INV 383.00 385.35 TC386.40 + BODY SHOP BC385.90 385

LOUNGE 385.0 385.5 385

TC386.40 + 385.0 BC385.90 + 385.5 385.15

385.5 PARTS

DRAWINGS ALTERATION + NOTICE: LINCOLN SHOWROOM TC386.60 It is a violation of Section

SERVICE A SERVICE B BC386.10 69.5b of the New York State 386 Education Department for any person, unless acting 385.5 under the direction of the licensed architect, to alter this item in any way. If an item 386.5 + 385.38 bearing the seal of the architect is altered the architect shall affix their seal E FORD SHOWROOM 386.0 and the notation "altered by" 385.5 followed by the architect's TC386.65 signature, date of alteration, FFE 386.70 + + BC386.15 and a specific description of 385.5 the alteration. TC386.60 385.5 COPYRIGHT: + BC386.10 + + TC386.25 All production and intellectual 386.40 386.60 FFE

44.3'± BC385.75 property rights reserved. 386.70 + + + TC386.40 TC386.10 © Copyright 2018 386.50 + + + BC385.80 BC385.60 John Snyder Architects, + + PLLC 386.30 386 TC386.60

385.5 TC386.40 BC385.90 BC386.10 386.40 386 + Addendum Schedule + TC386.35 TC386.50 + BC385.85 73.3'± BC386.00 385.90 + + SAWCUT + +

385.87 385.85 385.84 386.0 SAWCUT

TC387.00 386.0 388 BC386.50 386.90 386.0 + +

386.5 TR +387.00 386.0 387.40 387.0 TC386.40 + BC385.90 + + 388.10 388.5 D 388 388

387.0 TC386.60 386.5 + TC387.00 388.10 BC386.50 BC386.10 TR

+ +

TR

TR TR TR

C Maguire Ford - GRADING LEGEND GRADING AND DRAINAGE NOTES Lincoln 386.0 EXISTING CONTOUR LINE 1. PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL UNDERGROUND UTILITIES. 386.0 PROPOSED CONTOUR LINE IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO UTILIZE A LOCATING SERVICE TO VERIFY UNDERGROUND EXISTING SPOT ELEVATION UTILITY LOCATIONS.

+ 463.55 PROPOSED SPOT ELEVATION 2. THE CONTRACTOR SHALL STAKE OUT ALL GRADES IN THE FIELD AND NOTIFY THE OWNER'S REPRESENTATIVE DIRECTION OF SURFACE FLOW IMMEDIATELY OF ANY DISCREPANCIES.

13 3. THE CONTRACTOR SHALL GRADE THE SITE TO PROVIDE CATCH BASIN L600 POSITIVE DRAINAGE TO CATCH BASINS AND DRAIN INLETS.

6" HDPE 12 STORM SEWER PIPE TRENCH L600 B

504 S Meadow St. Ithaca, NY 14850

Site Plan Review

12/05/2018

Grading and Drainage Plan

PROJ # 1905A L400 A

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Greenspace Plan Scale: Adjusted to 1” = 40’-0”

1 2 3 4 5 6 7 8 9 10

700 Cascadilla St Suite 203 Ithaca, NY 14850

P: 607.273.3565

www.js-architects.com

H DISTURBED GREENSPACE SOILS (497 SF) (2,536 SF) GREENSPACE (114 SF) GREENSPACE (407 SF)

DISTURBED DISTURBED SOILS (378 SF) SOILS (476 SF)

GREENSPACE DISTURBED GREENSPACE SOILS (553 SF) GREENSPACE (252 SF) (154 SF) GREENSPACE (114 SF) (94 SF)

DISTURBED G DISTURBED DISTURBED GREENSPACE GREENSPACE SOILS (152 SF) SOILS (1,033 SF) SOILS (132 SF) (136 SF) (52 SF) GREENSPACE DISTURBED GREENSPACE (196 SF) SOILS (625 SF) (554 SF)

GREENSPACE SERVICE DRIVE THRU (311 SF) DISTURBED SOILS (456 SF)

PARTS RECEIVING GREENSPACE (4,579 SF)

BODY SHOP

LOUNGE

F

PARTS

LINCOLN SHOWROOM DISTURBED SOILS SERVICE A SERVICE B (35,158 SF)

DRAWINGS ALTERATION NOTICE: It is a violation of Section FORD SHOWROOM 69.5b of the New York State Education Department for any person, unless acting under the direction of the licensed architect, to alter this item in any way. If an item bearing the seal of the architect is altered the architect shall affix their seal E and the notation "altered by" followed by the architect's GREENSPACE GREENSPACE signature, date of alteration, (332 SF) and a specific description of (1,260 SF) the alteration.

COPYRIGHT: All production and intellectual property rights reserved. © Copyright 2018 GREENSPACE John Snyder Architects, DISTURBED SOILS PLLC (739 SF) (1,444 SF) DISTURBED SOILS Addendum Schedule (1,935 SF)

GREENSPACE

(3,515 SF) TR

D

LEGEND

C

135,288 SF (3.10 AC.) SITE AREA Maguire Ford - PROPOSED Lincoln GREEN SPACE (15,312 SF, 11.3%)

RECREATIONAL WALKS TO WEGMANS AND (922 SF, 0.7%) SOUTH MEADOW STREET

DISTURBED SOILS B (43,086 SF O.99 AC.)

504 S Meadow St. Ithaca, NY 14850

Site Plan Review

12/05/2018

Greenspace Plan

PROJ # 1905A L301 A

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Planting Plan Scale: Adjusted to 1” = 40’-0”

1 2 3 4 5 6 7 8 9 10

700 Cascadilla St Suite 203 Ithaca, NY 14850

P: 607.273.3565

www.js-architects.com

H

9 5 PF 3 PS PS 1 GT

G 1 LAWN TC

2 2 LAWN GT GT 1 UA 1 TC

LAWN LAWN

1 LAWN UA LAWN SERVICE DRIVE THRU 1 PV

LAWN 2 CC PARTS F RECEIVING

BODY SHOP

LOUNGE 1 2 UA CC 1 AS

PARTS

DRAWINGS ALTERATION NOTICE: LINCOLN SHOWROOM It is a violation of Section 1 SERVICE A SERVICE B 69.5b of the New York State UA Education Department for any person, unless acting LAWN under the direction of the licensed architect, to alter this item in any way. If an item 1 bearing the seal of the AS architect is altered the architect shall affix their seal E FORD SHOWROOM and the notation "altered by" followed by the architect's 10 signature, date of alteration, and a specific description of PF 1 the alteration. UA COPYRIGHT: All production and intellectual 1 property rights reserved. LAWN 1 © Copyright 2018 AS John Snyder Architects, UA PLLC LAWN 2 2 4 CC 1 PV Addendum Schedule RA CC 1 PV 17 1 CC 2 RA 1 PLACE JUNIPERS AMONG THE PV 7 TC EXISTING STONES (TYP.) PF

D 15 LINCOLN RA FORD SIGN SIGN 15 PF LAWN TR LAWN LAWN

1 1 1 5 5 5 5 AS AS AS JH JH JH JH

C Maguire Ford -

PLANTING NOTES: PLANTING LEGEND: PLANTING LIST Lincoln 1. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO COMMENCING SYM. QTY. BOTANICAL NAME COMMON NAME SIZE ROOT NOTE PLANTING WORK AND NOTIFY THE OWNER'S REPRESENTATIVE IMMEDIATELY IF CONDITIONS DETRIMENTAL TO NEW AND EXISTING PLANT MATERIAL ARE DECIDUOUS TREES EXISTING TREE ENCOUNTERED. AS 6 ACER SACCHARUM 'LEGACY' LEGACY SUGAR MAPLE 3"-3.5"DBH B&B 2. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY THE PV 6 PRUNUS VIRGINIANA 'SHUBERT' CANADA RED CHOKECHERRY 2.5"-3"DBH B&B TREE FORM LOCATIONS OF ALL UNDERGROUND UTILITIES. IT IS THE RESPONSIBILITY OF CC 8 CERCIS CANADENSIS 'NORTHERN STRAIN' EASTERN REDBUD 2.5"-3"DBH B&B TREE FORM THE CONTRACTOR TO UTILIZE A LOCATING SERVICE TO VERIFY UNDERGROUND UTILITY LOCATIONS. GT 5 GLEDITSIA TRIACANTHOS INERMIS THORNLESS HONEY LOCUST 3"-3.5" DBH B&B TYPICAL DECIDUOUS TREE PLANTING 9 TC 3 TILIA CORDATA LITTLE LEAF LINDEN 3"-3.5" DBH B&B 3. THE CONTRACTOR SHALL STAKE LOCATIONS OF ALL PLANT MATERIALS 600 PRIOR TO INSTALLATION. NOTIFY THE OWNER'S REPRESENTATIVE WHEN UA 6 ULMUS ACCOLADE ACCOLADE HYBRID ELM 3"-3.5" DBH B&B STAKING IS COMPLETE, AT WHICH TIME A MEETING WILL TAKE PLACE TO DETERMINE FINAL LOCATIONS. SHRUBS B PF 41 POTENTILLA FRUTICOSA YELLOW YELLOW POTENTILLA 18"-24" HGT. #3 CONT. 4. ALL PLANT BEDS AND TREE PITS SHALL RECEIVE 4" OF SHREDDED BARK GROW-LOW SUMAC 12"-18" HGT. #3 CONT. MULCH. RA 17 RHUS AROMATIC GRO-LOW TYPICAL FLOWERING TREE PLANTING 9 600 PS 7 PANICUM VIRGATUM 'SHENDOAH' SWITCH GRASS 12"-18" HGT. #3 CONT. 504 S Meadow St. 5. THE CONTRACTOR SHALL TOPSOIL AND SEED LAWN AREAS AND ALL AREAS BLUE RUG JUNIPER 12"-18" SPD. #2 CONT. Ithaca, NY DISTURBED AS A RESULT OF NEW CONSTRUCTION. JH 20 JUNIPERUS HORIZONTALIS 'BLUE RUG' 10 14850 TYPICAL SHRUB PLANTING 600 Site Plan Review 1 PLANT QUANTITY GT PLANT SYMBOL 12/05/2018

Planting Plan

PROJ # 1905A L500 A

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Site Details Scale: NTS

1 2 3 4 5 6 7 8 9 10

8'-0" O.C. MAX.

36" HARDWOOD OR STEEL FENCE POST, 2" SMOOTH DRIVEN MIMIMUM 16" INTO GROUND. ATTACH TROWELED PAVEMENT SECTION FABRIC SECURELY TO FENCE POSTS. LOCATE CONCRETE RAMP COURSE BROOM FINISH IN CONCRETE BAND UNDER UNDER FINISH GRADE FENCE POSTS DOWN SLOPE OF FABRIC. AROUND PANEL DIRECTION AS SHOWN PAVEMENT LAWN AREA 700 Cascadilla St Suite 203 SCORE JOINT Ithaca, NY 14850 TRENCH AND EMBED FENCE A MINIMUM OF 8" PROVIDE FLARED TRANSITION ONLY WHERE INTO GROUND INDICATED ON PLANS. COURSE BROOM FINISH STABILIZE SIDE SLOPES BACKFILL TRENCH AND COMPACT SOIL AS REQUIRED P: 607.273.3565 1:12 MAX. IN DIRECTION AS SHOWN RAMP DOWN

6'-0" SCORE JOINT UNDISTURBED SUBGRADE SCORE JOINT SCORE JOINT 18" 8" MIN. MIN. 24" EMBEDED POLYFIBER DETECTABLE FINAL BACKFILL, COMPACTED www.js-architects.com SILT FENCE FABRIC WARNING PANEL PER ADA REQUIREMENTS. SUITABLE NATIVE BACKFILL COLOR: RED, FULL LENGTH OF RAMP FINAL BACKFILL, EXP. JOINT EXP. JOINT COMPACTED AGGREGATE SUBBASE MATERIAL, NYSDOT CONCRETE CURBING TYPE 4, ITEM 304.14 6'-0" TRANSITION CURB FLUSH CURB 6'-0" TRANSITION CURB ISOMETRIC VIEW INITIAL BACKFILL AND HAUNCH 5'-0" TYP. 6"

MIN. MATERIAL, COMPACTED AGGREGATE H PLAN VIEW SUBBASE MATERIAL, NYSDOT TYPE 4, ITEM 304.14

DIA. STORM SEWER PIPE

36" HARDWOOD OR STEEL FENCE POST, PIPE DRIVEN MIMIMUM 16" INTO GROUND. ATTACH PIPE BEDDING, FABRIC SECURELY TO FENCE POSTS. LOCATE TOP OF RAMP (FINISHED GRADE) 6" COMPACTED AGGREGATE 6" SUBBASE MATERIAL, NYSDOT FENCE POSTS DOWN SLOPE OF FABRIC. MIN. CONCRETE CURBING TYPE 4, ITEM 304.14 SILT FENCE FABRIC 12" UNDISTURBED SUBGRADE

20" PIPE 6" SEDIMENT BUILD-UP, MAINTAIN AT 12" MAX. 6" 6" 6" 6" COMPACTED AGGREGATE SUBBASE MIN. DIA. MIN. DISTURBED TRENCH AND EMBED FENCE A MINIMUM OF 8" MATERIAL. NYSDOT TYPE 2, ITEM 304.12 AREA INTO GROUND STORM SEWER PIPE TRENCH COMPACTED SUBGRADE 12 NOT TO SCALE 8" DEEP TRENCH, BACKFILL WITH ELEVATION COMPACTED SOIL

AREA DRAIN UNDISTURBED GROUND EXPANSION JOINT 16" 6'-0" STANDARD H20 RATED DUCTILE IRON ROUND FINISHED GRADE 10" DIA. DUCTILE IRON FRAME AND GRATE FRAME AND GRATE RAMP DOWN 1:12 MAX. 1/4" REVEAL BLACK PAINTED FINISH GRATE 6" COMPACTED AGGREGATE SUBBASE 12" NYLOPLAST MATERIAL. NYSDOT TYPE 2, ITEM 304.12 5' x 5' CONCRETE COLLAR SECTION DRAIN BASIN (PVC BODY) HDPE PIPE ADAPTOR FINISH GRADE, CONCRETE CURBING G SEDIMENT CONTROL FENCE SLOPE LAWN AREA 1 NOT TO SCALE SECTION

2"x4" WOOD FRAME ADA RAMP 6" HDPE STORM PIPE 7 NOT TO SCALE

SPACE STAKES EVENLY AROUND INLET WITH A 3' MAX. SEPARATION DISTANCE ADA HANDICAP SIGN 6" DEPTH #2 CRUSHED STONE COMPACTED TO

CONCRETE CURB 6" 95% MODIFIED PROCTOR 18" MIN.

6' TRANSITION CURB 1' SEDIMENT CONTROL CATCH BASIN FENCE FABRIC, EMBED 4" WIDE PARKING LINE PAINTED BLUE 13 NOT TO SCALE IN GROUND 12" MIN. NON HC SECURELY FASTEN 5' FLUSH CURB AND RAMP FENCE TO WOOD PARKING SPACE ADA HANDICAP SYMBOL PAINTED BLUE STAKES AND OVERLAP 18'-0"

3'-0" MIN. ANY JOINTS TO THE NEXT STAKE 4" WIDE NO-PARKING AREA PAINTED WITH 4" WIDE F PARKING DIAGONAL LINES PAINTED BLUE LINES PAINTED WHITE MAXIMUM SLOPE WITHIN HC SPACE AND CATCH BASIN INLET STRIPED ISLE SHALL NOT EXCEED 2%

9'-0" 8'-0" 8'-0" INLET PROTECTION MIN. 2 NOT TO SCALE HC PARKING LAYOUT 8 NOT TO SCALE 3/8" WIDE COMPRESSIBLE EXPANSION JOINT FILLER WITH SEALANT DRAWINGS ALTERATION SMOOTH FINISH SEE PLANS FOR LAYOUT NOTICE: 3/4"Ø x 15" LONG STEEL DOWELS @ 24" It is a violation of Section O.C., 7 1/2" EMBEDMENT EACH END, TOOLED JOINT 69.5b of the New York State GREASE ONE END Education Department for any person, unless acting 1" DEEP x 1/4" WIDE SAW CUT SCORE JOINT 2" under the direction of the SEE PLANS FOR LAYOUT licensed architect, to alter this SOFT BRISTLE item in any way. If an item 4" THICK CONCRETE PAVEMENT, PROVIDE BROOM FINISH 4" bearing the seal of the SOFT BRISTLE BROOM FINISH architect is altered the PERPENDICULAR TO EDGE RUBBER HOSE architect shall affix their seal E 6" and the notation "altered by" 6X6 - W2.9XW2.9 WWM (2" CLEAR) FRICTION GUARD followed by the architect's 6" COMPACTED AGGREGATE signature, date of alteration, #12 GAUGE GALVANIZED ANNEALED WIRE WITH SUBBASE MATERIAL NYSDOT and a specific description of TURNBUCKLE TYPE 2, ITEM NO. 304.12, COMPACTED TO the alteration. 95% MODIFIED PROCTOR 3" DIA. X 7' CEDAR STAKE, STABILIZATION GEOTEXTILE CONCRETE FINISH (3) AT 180° SPACING COPYRIGHT: All production and intellectual COMPACTED SUB-GRADE 4" SHREDDED BARK MULCH TREE RING TREE TRUNK property rights reserved. 4'-0" FINISH GRADE, MULCH SURFACE © Copyright 2018 CONCRETE PAVEMENT-PEDESTRIAN TRAFFIC ROOT BALL John Snyder Architects, 3 4" DEEP SAUCER NOT TO SCALE 3" DIA. X 7' CEDAR PLLC STAKE, (3) AT 180° SPACING BACKFILL TREE PIT WITH AMENDED TOPSOIL Addendum Schedule

3/8" WIDE COMPRESSIBLE EXPANSION TREE PIT TO BE 1X BALL DEPTH #12 GAUGE GALVANIZED BY 2X BALL WIDTH, SCARIFY JOINT FILLER WITH SEALANT SMOOTH FINISH ANNEALED WIRE WITH TURNBUCKLE

SEE PLANS FOR LAYOUT 3'-0" ROOT BALL 3/4"Ø x 15" LONG STEEL DOWELS @ 24" RUBBER HOSE TOOLED JOINT UNDISTURBED SUBGRADE O.C., 7 1/2" EMBEDMENT EACH END, FRICTION GUARD GREASE ONE END TREE GUYING DETAIL 2" 1.5" DEEP x 1/4" WIDE SAW CUT SCORE JOINT SEE PLANS FOR LAYOUT TYPICAL DECIDUOUS TREE PLANTING SOFT BRISTLE 9 NOT TO SCALE D 6" 6" THICK CONCRETE PAVEMENT, PROVIDE BROOM FINISH SOFT BRISTLE BROOM FINISH PERPENDICULAR TO EDGE SPACE AS NOTED ON PLANT LIST AND PLANS 6X6 - W2.9XW2.9 WWM (2" CLEAR) DOUBLE ROW 12" 12" COMPACTED AGGREGATE SUBBASE MATERIAL NYSDOT TYPE 2, ITEM NO. 304.12, COMPACTED TO 95% MODIFIED PROCTOR STABILIZATION GEOTEXTILE CONCRETE FINISH COMPACTED SUB-GRADE CONCRETE PAVEMENT-VEHICULAR TRAFFIC 4 NOT TO SCALE FINISH GRADE, MULCH SURFACE

1 1/2" ASPHALT TOP COURSE 4" SHREDDED BARK MULCH NYSDOT ITEM 402-128202

3-1/2" ASPHALT BINDER COURSE

5" NYSDOT ITEM 402.198902 ROOTBALL OR CONTAINER 1'-0" 12" COMPACTED AGGREGATE SUBBASE MATERIAL NYSDOT C 12" TYPE 2, ITEM NO. 304.12, COMPACTED TO 95% MODIFIED PROCTOR AMENDED TOPSOIL 1'-0"

STABILIZATION GEOTEXTILE UNDISTURBED SUBGRADE Maguire COMPACTED SUBGRADE ASPHALT PAVEMENT Ford - 5 NOT TO SCALE TYPICAL SHRUB PLANTING Lincoln 10 NOT TO SCALE

12" FINISH GRADE, SURFACE VARIES ENGINEER GRADE STEEL SIGN PANEL PROVIDE EXPANSION JOINT WHERE CURB (MUTCD R7-8) PER ADA REQUIREMENTS ABUTTS CONCRETE WALK 18"

1" RADIUS 6" 1" #4 BAR CONTINUOUS, TOP AND BOTTOM, 3" CLEAR STEEL U-CHANNEL TYPE A SIGN POST, 5'-0" B 6" PAINTED BLACK. NYSDOT ITEM 645.81 FINISH GRADE, ASPHALT PAVEMENT

BREAKAWAY COUPLING 504 S Meadow St. 18" CAST IN PLACE CONCRETE CURB, SMOOTH Ithaca, NY RUBBED FINISH EXPOSED SURFACES FINISH GRADE 14850

UNDISTURBED SUBGRADE Site Plan Review

6" COMPACTED AGGREGATE SUBBASE MATERIAL 3'-0" 10" DIA. CONCRETE FOOTING COMPACTED SUBGRADE 12/05/2018 NOTE:

4" 7" PROVIDE VERTICAL EXPANSION 6" JOINTS 20' O.C. MAX. SPACING. Site Details CONCRETE CURB EXTERIOR SIGNAGE 6 NOT TO SCALE 11 NOT TO SCALE PROJ # 1905A L600 A

1 2 3 4 5 6 7 8 9 10

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC Perspective View 1 Revised Scale: NTS

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC East & West Rendered Elevations Revised Scale: 1/8” = 1’-0”

M1 EP3 EG1 MP2 MP1 EG1 MP2 MP1 MP1

EG1

East Elevation

MP3 M1 EP3

West Elevation

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC North & South Rendered Elevations Revised Scale: 1/8” = 1’-0”

MP EG1 MP2 MP1 MP4 MP MP1 MP3 M1

North Elevation

MP3 M1 EP3

South Elevation

Maguire Family Limited Partnership: Maguire Ford-Lincoln 504 S. Meadow Street, Ithaca, NY 14850 December 5th, 2018 Permit No: 38012 © 2018 John Snyder Architect, PLLC