Ministry of ORDER NO. 88-110 Agriculture AUGUST 1988 AGDEX J.gQ and Food 736

BARN DRYING (Revision ofFactsheet " Hay Drying", February 1988) H.K. and R.P. Stone, Agricultural Engineering Services

INTRODUCTION 2. AIRFLOW RATES Barn hay drying systems are commonly installed today as Hay dryers should be designed to complete the curing of a basic component in the production of quality forage. A tough or damp hay and not be expected to dry wet hay. The properly managed hay drying system reduces field curing amount ofairflowrequireddepends on the initial hay moisture time and thus lessens the risk oflosses due to rain, minimizes content and the grass-legume mixture of the forage. The leafloss, and eliminates the danger offire due to spontaneous following airflow rates (Figure 2) can be used as a guideline. combustion. HA Y MOISTURE AIRFLOW RATES CONTENT % cfrn/ton (Us/tonne) <25 150 (80) 25-30 300 (160) 30-35 500 (260)

Figure 2 Airflow Rates for Varying Hay Moisture Content

The most desirable average hay moisture content for bam drying is 25%or less. An average moisture content exceeding 30% can become very risky for artificial drying. For calculation purposes one ton (0.9 tonne) of dry baled Figure 1 Hay Dryers Assist in Producing a Quality Forage hay occupies approximately 250 cubic feet (7.Om') ofspaceor consists of approximately 50 standard bales weighing 40 A barn hay dryer makes use of a suitable fan and air duct pounds (18 kg) each. distribution system to force outside air through partially dried hay, placed in storage. This movement ofair through the hay removes heat and excess moisture and will eventually com­ 3. THE DRYING FAN plete the drying process which started in the field. The fan is selected to deliver the desired amount ofair at a The following factors must be considered when investigat­ static pressure of I" (0.25 kPa). There are two types of fans ing the installation of a hay drying system for your . used; the axial flow (propeller) fan or the certrifugal fan. A centrifugal fan operates much quieter than an axial fan but is also more expensive. 1. MOW FLOOR Generally, 5 horsepower (3.7 kW) or 7.5 horsepower 1. Hay to be dried will weigh 10 to 30% more than field (5.6kW) axial or centrifugal fans are readily available. More dried hay. All floor supports should be checked and than one fan, if necessary, may be installed on a hay storage strengthened or replaced if necessary. to meet the airflow requirements. 2. The mow floor must be air tight so that air is forced Ifcentrifugal fans are used to dry the hay, a constant check through the hay and not through the floor. The floor must be kept on the drive belt tension. Any loss in revolutions can be sealed with a 6 mil (0.15 mm) polyethylene per minute due to excessive belt slippage will reduce the fan plastic or covered with 5/16" (8 mm) thick plywood. output considerably. Electrical requirements for the fan motorcan be substantial 4. AIR DISTRIBUTION SYSTEMS and should be considered in the original planning process. The air distribution system comprises a main air duct with The fan should be located where it can be easily reached for or without a slatted floor section, depending on the mow maintenance and repair, and should also be protected from the dimensions (Figure 4). Air is forced into the duct system by weather. Remember when selecting the fan location that it the fan which delivers air throughout the hay mow. will be running continuously for a period oftime and making considerable noise. The main air plenum is a rectangular plywood-lined air tight duct that is smooth on the interior to allow unrestricted airflow. Air control are located along the base of the duct walls and on top ofthe duct to direct air into the hay. The doors also control the airflow to different mow sections.

1. 2"x4" (38x89mm) slats 00 spaced 3" (75mm) apart 2. 2"x6" (38xI4Omm) spaced ~-~- (;) 24" (600mm) O.c. (;) I (;) (;) 3. 2"x6" (38xI4Omm) plate (i) 4. Duct Lining 5. Mow Floor 6. l"x6"(19xl40mm) blocking 7. 12" (300mm) air control (;) (;) (;) , =-- 8. l"x4" (19x89mm) slats An Figure 3 Axial Hay Drying Fan with Electric Controls. spaced 12" (300mm) o.c. 9. l"x4" (l9x89mm) continu- EXAMPLE SYSTEM - FAN SELECTION ous nailer Example: Calculate the required fan capacity to dry a mow Figure 4 Lined Rectangular Duct Without Slatted Floor ofhay with dimensions 30' (9.1 m) x 70' (21.3 m) Courtesy At/antic Provinces Pub. No.8 x 12' (3.65 m) deep when the hay has an initial moisture content of25%. The main air plenum is located either through the centre section ofthe hay storage or along one side. Side·wall main SOLUTION ducts are used wi th narrowermows-less than 24' (7.3m). The advantage of side-wall ducts is the ease of working around I. Volume of Storage = length x width x depth them in the mow. However, it is more difficult to make side­ = 30' (9.1 m) x 70' (21.3 m) x wall duct systems airtight. 12' (3.65 m) = 25200 cu. ft. (707 cu. m.) A triangular duct may be constructed as the main air plenum in place ofthe rectangular or square ducl. The height 2. 1 ton (0.9 tonne) ofdry baled hay occupies 250 ft' (7.0 ofthis duct often becomes too great for moving bales over the m3); thus the mow hay volume is top from one side of the mow to the other. Also, it is difficult to stack a mow tightly around a triangular plenum. The 25200 ft'(707m') triangular duct is used most successfully when bales, shorter ----'------'--100 ton than 30" (0.76 m.) in length are randomly dropped into the 250 ft' (7.0 m') (90 tonne) mow without being stacked in a conventional manner.

3. From Figure 2 for 25% moisture content hay, the Ducts may also be constructed without an interior lining airflow rate is 150 cfm/ton (80 Lls/tonne). provided that the distance the air has to travel to the perimeter Thus, select a fan that will deliver of the mow is equal over the entire mow. The flexibility of 100 ton (90 tonne) x 150 cfm/ton (80 Lls/tonne) = drying sections ofthe mow separately is lost with an unlined 15000 cfro ducl. A hay duct, constructed ofhay sides and a plank top can or 7200 LIs of air at 1" (0.25 kPa) static pressure. also be used as a main duct with the same limitations as the unlined ducl. 4. Check with your supplier for an appropriate fan. The layout ofthe air duct and slatted floor should provide Manufacturer's data may suggest a 36" (914 mm) for equal travel distance for the air to move to the outside diameter axial fan with a 5hp(3.7kW) electric motor. perimeter of the mow. (Figure 5). --(' ------~ i /' \ \ \ / \ \ "­ / \ /- ---'-, --~\ f " ~\ "Pile Bales to '" / " Air Provide Equal Path ~\ \ Plenum Length Of Air Flow / \ \ // ,x \ L E~-:2·:·I:~:~~:-~:·~··3~,~,.~·.~,'..~.:~. ,~·U:~,'~~;~~:~~~s~\~,~·f~~ .. ~.~·.~·,:~· ~·~"t:··h======J First Bale Row On LTightly Packed Bales Edge And Spaced 4" to 6" On Edge (100 mm to 150 mm)

Figure 5 Equidistant Air Travel Path Through a Mow of Hay

Therefore, ifthe distance from the main duct air slot to the Slatted floors should neverbeused wherethe distance from outside walls and to the mow top are equal, a slatted floor is the main duct to the outside ofthe mow is less than to the top not necessary. A single row of bales placed on edge at right ofthe mow, as the air will short-circuit through the sides ofthe angles to duct, with4"-6" (1 00-15Omm) spaces between them mow. should be provided as a minimum. These air channels will lessen the pressure around the duct. Beyond the first balerow 5. DESIGNING THE SYSTEM spacing, more bale row openings may be provided to achieve the equal air travel distance through the solid packed hales to Thefollowing points must be kept in mind when designing the mow perimeter (Figure 6). the system: 1. Themain airduct should be sized to providea minimum of I square foot (.09 sq.m.) of cross sectional area for every 1000 cfrn (470 LIs) of fan capacity. 2. Air control doors should be sized to create a maximum airvelocity through the openingof500fpm (2.5 mls) or provide 2 square feet (0.18 sq.m.) of opening area for every 1000 cfrn (470 LIs) of fan capacity. -----_.. 3. Air control doors should not be installed closer than 8 _,',. ," -l P -..J~~' feet (2.4 m) to the ends ofthe main duct. Thefirst 8 feet \00"''''-150 ...... (2.4 m) ofduct next to the fan should always be tightly sheathed. Figure 6 Perspective of Hay Dryer with Bottom Layer of 4. Provide 2 square feet (0.18 sq.m.) ofopening from the Bales Spaced to form Air Channels mow to the outside for every 1000 cfm (470 LIs) of fan Courtesy Atlantic Provinces Pub/ieation No.8 capacity for exhaust air discharge. 6. HARVESTING AND FILLING 3. !fheating is evident run the fan for a day or two and re­ check. The hay dryeris designed to dry toughor damp hay and not wet hay. Field dry the hay to an average moisture content of 4. !fno heating is evident after three checks, the hay may 25% before baling. Hay with a higb grass content may be be considered dry. baled with a slightly higher moisture level. Bale the hay at normal baler tension and make slight adjustments, if neces­ sary, for high moisturecontents. Rememberthat the bales will 8. COST shrink: slightly during the drying process. The capital cost ofthe hay drying system will vary depend­ Hay should be placed uniformly over the entire mow ingon the type and size ofsystem, the available materials and section being dried. Pack the mow tightly with the bottom labour. As of 1986, the minimum cost ofa hay drying system layer of bales on edge. The upper remaining layers of bales including an axial fan, the main air plenum (no slats) but with may be placed flat with alternate layers at right angles to each no labor cost for building the duct would be $2500. This cost other. could easily be doubled if a centrifugal fan was installed and The fan should be started once the loading of the mow hired labor was used to construct the ductwork. commences. Enough hay must be placed on the dryer the first Operating costs will depend on hay moisture content and day to adequately cover the floor and duct section. This weather conditions during the drying period. An average ensures that effective drying can begin. energy usage of 50-75 kWh/ton (55-83 kWh/tonne) can be expected. Using a 1986 electrical charge of$0.045/1