ES-LF288A

Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––– LEAD FREE* Series LF288A Hot or Cold Anti- Breakers Sizes: 1⁄4" - 3" Series LF288A represents a complete line of vacuum breakers designed to prevent backsiphonage of contaminated water into a potable . They feature a lightweight, durable “disc float" suitable for tem- peratures up to 180°F (82°C) which closes the atmospheric vent to prevent spilling under all rates of flow. Therefore, they are ideally recommended for low flow installations such as laboratory equip- ment which use such a small amount of water. They also contain 1/2" LF288A a durable silicone disc which has high heat and water hammer shock resistance and assures tight seating with the lightest of seating contact. The LF288A Features Lead Free* construction to comply with Lead Free* installation requirements. Center Stem Guide for accurate seating Full Size Orifice - Series LF288A has a full-size orifice to assure pipe size capacity. Water passages are streamlined to provide high water flow with minimal loss. Disc has high heat and water hammer For bottom/inlet and outlet connection type vacuum breakers 1⁄4", shock resistance 3⁄8" size, refer to ES-LFN388. Features Disc Float durable and light- • Lead Free* Brass Body weight, closes vent with minimum flow • Full size orifice for maximum flow • Lightweight disc assembly prevents spilling under all rates of flow Full Size Orifice assures pipe Models size capacity LF288A 1/4" – 3/4" with Lead Free* brass body LF288A-C 1/4" – 3/4" with Lead Free* brass body and polished chrome finish Since atmospheric type vacuum breakers are subject to normal main- LF288AM4 1" tenance and replacement, they should be located where emergency water spillage will create no problem and where they can be accessible LF288AM2 11/4" – 3" for inspection or servicing. Specifications NOTICE For Anti-Siphon Vacuum Breakers This device shall not be subjected to continuous pressure for more than twelve (12) hours per ASSE Std. 1001. For continuous pressure An atmospheric type anti-siphon shall be installed application, specify Watts Series LF800 pressure type vacuum break- where indicated on the plans to prevent the backsiphonage of ers. Vacuum breakers are not designed, tested or approved to protect contaminated water. Device shall include lightweight disc float with against backpressure backflow. For protection against backpressure silicone disc for tight seating. This device backflow, install Watts Series LF909 or Series LF009 reduced pressure is not to be used under continuous pressure or where there is a principle backflow preventers. possibility that a backpressure condition may develop. The Hot or Cold Water Anti-Siphon Vacuum Breakers shall be constructed using Lead Free* materials. Lead Free* Hot or Cold Water Anti- *The wetted surface of this product contacted by consumable Siphon Vacuum Breakers shall comply with State codes and water contains less than 0.25% of lead by weight. standards, where applicable, requiring reduced lead content. The device shall meet the requirements of ASSE Standard 1001, ANSI A112.1.1 and CSA B64 and shall be a Watts Series LF288A.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. NOTICE Capacities 1 3 The information contained herein is not intended to replace the full kPa psi /4" to /4" product installation and safety information available or the experience 83 12 1 3 1 of a trained product installer. You are required to thoroughly read all /4" /8" /2" 3/4" installation instructions and product safety information before begin- 69 10 ning the installation of this product. 55 8

41 6 Materials 28 4 Body: Lead Free* brass Pressure Loss Disc: Silicone 14 2 0 0 Pressure — Temperature 0 5 10 15 20 25 30 35 gpm 0 19 38 7 76 95 114 113 lpm Maximum Temperature: 180°F (82°C) Flow Rate Maximum Working Pressure: 125psi (8.6 bar) 1 1 kPa psi 1", 1 /4", 1 /2" Installations 83 12 1" 1 Atmospheric VB must be installed 6" above the highest point 69 10 1 /4" on the downstream piping. There can be no shutoff valves downstream of an AVB. 55 8

41 6 1 Approvals 1 /2" 28 4 Pressure Loss 14 2

0 0 1001 B64.1.1 0 10 20 30 40 50 60 70 80 gpm 0 38 76 114 152 190 228 266 304 lpm Certified thru 1" (25mm) CSA Flow Rate

1 kPa psi 2", 2 /2", 3" 83 12 2" 21/2" 69 10 Dimensions — Weights 55 8 3"

A 41 6

28 4

C Pressure Loss 14 2

0 0 0 50 100 150 200 250 300 350 400 450 500 gpm D 0 190 380 570 760 950 1140 1130 1520 1710 1900 lpm Flow Rate

SIZE WEIGHT A B C D in. in. mm in. mm in. mm in. mm oz. gm. 1⁄4 13⁄4 44 21⁄4 57 11⁄4 32 1 25 6 170 3⁄8 13⁄4 44 21⁄4 57 11⁄4 32 1 25 6 170 1⁄2 2 50 23⁄4 70 11⁄2 38 11⁄4 32 8 227 3⁄4 21⁄4 57 3 76 11⁄2 38 11⁄2 38 18 510 1 27⁄8 73 35⁄8 92 17⁄8 48 13⁄4 44 28 794 11⁄4 27⁄8 73 33⁄4 95 17⁄8 48 17⁄8 48 34 964 11⁄2 35⁄8 92 41⁄2 114 21⁄4 57 21⁄4 57 54 1531 2 4 100 51⁄8 130 25⁄8 67 21⁄2 64 84 2381 21⁄2 61⁄2 165 71⁄2 191 41⁄2 114 3 76 256 7258 3 61⁄2 165 8 200 45⁄8 117 33⁄8 86 274 7768

USA: T: (978) 689-6066 • F: (978) 975-8350 • Watts.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • Watts.ca Latin America: T: (52) 81-1001-8600 • Watts.com ES-LF288A 1911 © 2019 Watts