4A | Carbon Dioxide Products

Total Page:16

File Type:pdf, Size:1020Kb

4A | Carbon Dioxide Products 4A | Carbon Dioxide Products RATERMANN MANUFACTURING, INC. INDEX Aluminum Carbon Dioxide Cylinders for Industrial Gas .................... 4A-4 Automatic Changeover Manifold ...................................................... 4A-15 Carbon Dioxide Accessories Polyethylene Tubing – Vent Hose ................................................ 4A-13 Carbon Dioxide Fittings ............................................................... 4A-12&13 Carbon Dioxide and Gas Purification ................................................ 4A-14 Carbon Dioxide Bulk Fittings Carbon Dioxide Hose End Assembly ........................................... 4A-12 Carbon Dioxide CGA 320 Valve Plugs ............................................... 4A-4 Carbon Dioxide Cylinder Boots ......................................................... 4A-5 Carbon Dioxide Hose Products CO2 Transfer Hoses – 450 PSIG .................................................. 4A-11 CO2 Wall Outlet – Wall Box Nipple with 6-Hole Flange ............. 4A-12 Food Grade LCO2 Transfer Hose for CO2 & Beverage ............... 4A-12 Thermoplastic Low-Temp Pigtails ................................................ 4A-7 Hose Reel for Thermoplastic Hoses .......................................... 4A-8, 12 Carbon Dioxide Piping & Manifold Beverage Manifold Accessories ................................................... 4A-10 CO2 Plug & Socket ...................................................................... 4A-10 Low Pressure Changeover Valve ................................................. 4A-10 Proportional Gas Mixer for Beverage Gases ............................... 4A-10 Carbon Dioxide Pump ....................................................................... 4A-11 Carbon Dioxide Regulators Beer Regulator ............................................................................ 4A-5 Soda Regulator ........................................................................... 4A-5 Carbon Dioxide Seals Cylinder Connections .................................................................. 4A-3 PTFE Seals for CO2 ..................................................................... 4A-3 Carbon Dioxide Valve Conversion Kit ................................................ 4A-3 Quick Fill Connector for CO2 ............................................................. 4A-8 Replacement Parts for Quick Fill Connector ................................ 4A-8 Residual Pressure Cylinder Valve ....................................................... 4A-6 Transfill Pump with Scale .................................................................. 4A-9 OTHER PRODUCTS Ball Valves, Carbon Steel with Vented Ball ........................................ 4A-15 Carry Handles for Aluminum Cylinders ............................................. 4A-2 Installing Carry Handles for Aluminum Cylinders ........................ 4A-2 Cylinder Retaining Rings for Carry Handles ...................................... 4A-2 Cylinder Safety Conversion Kit .......................................................... 4A-2 Dry Ice Machine ................................................................................ 4A-9 Dry Ice Accessories ...................................................................... 4A-9 E-Track & E-Track Restraints .............................................................. 4A-4 High Pressure Cylinder Caps ............................................................. 4A-5 Paint Ball 2 Lever Fill Station ............................................................ 4A-8 Retaining Ring Plier .......................................................................... 4A-2 Small Cylinder Status Tags ................................................................ 4A-3 Valve Leak Check .............................................................................. 4A-3 Rev: 3/21/16, 9/24/15, 9/16/14 Ratermann Manufacturing, Inc. Customer Service 1-800-264-7793 S Email [email protected] S Online at Web Store www.rmiorder.com 4A- 1 S Aluminum Cylinder Carry Handles – Choose your Color T C Aluminum Cylinder Carry Handles U Plastic Valve Protection Carry Handles are available to D fit Catalina® and Luxfer® brand aluminum cylinders. O We stock carry handles and retaining rings for both R manufacturers cylinders. For 15 and 20 lb. Aluminum P cylinders. Can be installed without removing valve. E Black (BK) Blue (B) Red (RR) For 15 & 20 lb. Aluminum Cylinders D I Part # Description X CCH-AC-xx Catalina® Style Carry Handle O CCH-AC-R Retaining Ring for Catalina® Style Carry Handles I CCH-AL-xx Luxfer® Style Carry Handle D CCH-AL-R Retaining Ring for Luxfer® Style Carry Handles N CCH-AS-xx Thread On Style Carry Handle O Catalina® Style Pt # CCH-AC-BK Ordering Information: B Luxfer® Style Pt # CCH-AL-BK Yellow (Y) Green (GR) Orange (O) R Replace xx in the part number with the color codes below A Note: All colors shown are printed representations. Actual colors may vary. Black – BK, Blue – B, Red – RR, Yellow – Y, Green – GR, Orange –O C Installing Carry Handles for Aluminum Cylinder 12 3 Cylinder Safety Cylinder Retaining Conversion Kit Rings for Carry Installing carry handle Handles valve protector Catalina® Style Pt # CCH-AC-R Handle & snap ring with steel cylinder adapter. Allows addition of plastic carrying handle to steel cylinders. Valve must be removed to Luxfer® Style install handle. Pt # CCH-AL-R Retaining Ring Plier (Adapter comes with set screws.) Cylinder Retaining Rings For all cylinder handle Part # Description retaining rings. Part # Description CCH-118 Conversion Kit 1.9” CCH-AC-R Retaining ring for Catalina® Part # Description CCH-AL-R Retaining ring for Luxfer® Rev: 7/1/13 CCH-P1 Retaining Ring Plier 4A- 2 Ratermann Manufacturing, Inc. Customer Service 1-800-264-7793 S Fax 1-800-264-7797 S Order Online at Web Store www.rmiorder.com C CO2 Cylinder Connections A Valve For Permanent Leak Proof R Conversion B Cylinder Connection O Kit N CARBON DIOXIDE Converts in D I 2 Minutes! • Hand Tight Lasts for Life of Valve O For aligning and • Self-Sealing Connections Designed X for Leak-Proof Dependability I tapping special D thread into valve • No Service Calls E outlet, so that the P Ring-Seal 3 piece R insert Unit can be O screwed in. D The ki t makes this U C simple and easy, Replacement Seals – Permanent Economy T while the valve O-Ring for CC-1 ABC Units Seal S stays on the Part # CC-1-OR Part # CC-1 Part # CC-P1 cylinder . The chips are blown out by the gas in the cylinder. Stems – 103 SF O-Ring for CC1-STEM 2 1/2” - 1/4” pipe Grip-Nut 103N Kit includes: Part # CC1-STEM-OR Part # CC1- STEM Part # CC1- NUT Special Drill (needed only PTFE Seals for CO2 on some valves) Special Tap Guide Collar Grip Nut Ring Grip Wheel Special Tag Handle Pt # CC-1 KIT Allen Driver PTFE Seal Thread Chaser Small Cylinder Status Tags Economy Paper Tags PTFE Seals for CO2 ± MOST COMMON Description Part # for Pack of 100 Part # Pack of 10 PTFE Seals for CO2 CO2-TWSEALPK100 CO2-TWSEALPK10 MOST PREFERRED FIBRE , 320/330 PH-320WFPK100 PH-320WFPK10 BY CUSTOMERS Elastic Tie Find your Leaks Fast and Easily Pt # CB-1EPTI with the Extending Tube to Get in the Hard to Reach Areas. Ratermann’s Oxygen Safe Valve Leak Check Small Economy Paper Tags Part # for Description Part # for Pkg. of 1000 Pkg. of 100 String Tie ± CB-EPTPK1000 String Tie (Pt # CB-EPTPK100) Pt # CB-EPT ± CB-1EPTIPK1000 Elastic Tie (Pt # CB-1EPTIPK100) The String Tie does not stretch or loop around Pt # LC-8OZ Pt # LC-1GAL the cylinder. Rev: 1/15/16, 2/13/14 Ratermann Manufacturing, Inc. Customer Service 1-800-264-7793 S Email [email protected] S Online at Web Store www.rmiorder.com 4A- 3 S Aluminum Carbon Dioxide Cylinders | Valve Plugs T C U Aluminum Carbon Dioxide Cylinders for Industrial Gas D Clean, corrosion-resistant, lightweight cylinders are ideal for dispensing carbonated soft O Models drinks, beers, lagers and other beverages. R available P include IDEAL FOR DISPENSING E CARBONATED SOFT DRINKS, BEERS, 2.5 lbs. D 5 lbs. I LAGERS AND OTHER BEVERAGES. 10 lbs. X 15 lbs. O I Features Manufactured to DOT and TC requirements D • Lightweight, high strength 6061-T6 • U.S. Department of Transportation (DOT) 3AL aluminum alloy improves cylinder system • Transport Canada (TC) 3ALM N portability while reducing the rigors of • Every cylinder inspected and tested by DOT- O material handling. and TC-authorized independent agency B • Corrosion-resistant interior and exterior • Cycle-tested in excess of 100,000 cycles at R • Brushed exterior provides a durable, service pressure A low-maintenance finish for years of C • Minimum burst pressure tested to 2.5 times dependable service. service pressure without failure • Optional carrying handle offers superior valve protection. SERVICE CO 2 MAX. N 2 OUTSIDE OVERALL EMPTY MIN. MIN. THREAD Note: PRESSURE CAP. CAPACITY DIAMETER LENGTH WEIGHT INTERNAL WATER SIZE Cylinder VOLUME WEIGHT colors may PART NO. PSI BAR LBS KG CU.FT LITERS IN. MM IN. MM LBS KG. CU.IN LITERS LBS KG vary from photo. CYL-CO2-2.5 1800 124 2.5 1.13 7.2 204 4.38 111.2 10.4 264 3.3 1.5 102 1.7 3.68 1.67 .750-16 UNF-2B CYL-CO2-5 1800 124 5.0 2.30 14.5 411 5.25 133.4 14.0 356 6.2 2.8 205 3.4 7.40 3.36 1.125-12 UNF-2B CYL-CO2-10* 180012410.04.5028.98186.89175.016.441712.95.94086.714.73 6.681.125-12 UNF-2B CYL-CO2-15* 18 0 0 124 15.0 6.80 43.3 1226 6.89 175.0 22.8 579 16.8 7.6 612 10.0 22.09 10.02 1.125-12 UNF-2B * 10 lb. and 15 lb. have the option of either a Carry Handle (add “ -H ”) or Cap and Collar (add “ -CC ”). E-Track & E-Track Restraints E-Track & E-Track
Recommended publications
  • Hydraulics Manual Glossary G - 3
    Glossary G - 1 GLOSSARY OF HIGHWAY-RELATED DRAINAGE TERMS (Reprinted from the 1999 edition of the American Association of State Highway and Transportation Officials Model Drainage Manual) G.1 Introduction This Glossary is divided into three parts: · Introduction, · Glossary, and · References. It is not intended that all the terms in this Glossary be rigorously accurate or complete. Realistically, this is impossible. Depending on the circumstance, a particular term may have several meanings; this can never change. The primary purpose of this Glossary is to define the terms found in the Highway Drainage Guidelines and Model Drainage Manual in a manner that makes them easier to interpret and understand. A lesser purpose is to provide a compendium of terms that will be useful for both the novice as well as the more experienced hydraulics engineer. This Glossary may also help those who are unfamiliar with highway drainage design to become more understanding and appreciative of this complex science as well as facilitate communication between the highway hydraulics engineer and others. Where readily available, the source of a definition has been referenced. For clarity or format purposes, cited definitions may have some additional verbiage contained in double brackets [ ]. Conversely, three “dots” (...) are used to indicate where some parts of a cited definition were eliminated. Also, as might be expected, different sources were found to use different hyphenation and terminology practices for the same words. Insignificant changes in this regard were made to some cited references and elsewhere to gain uniformity for the terms contained in this Glossary: as an example, “groundwater” vice “ground-water” or “ground water,” and “cross section area” vice “cross-sectional area.” Cited definitions were taken primarily from two sources: W.B.
    [Show full text]
  • Frequently Asked Questions
    FREQUENTLY ASKED QUESTIONS Pressure Washer Chemicals/Cleaners Q: Can I use chemicals that do not state pressure washer safe? Can I use bleach in my pressure washer? A: It is recommended that only cleaning products that state "pressure washer safe" be used. Please ensure to follow all of the manufacturer's instructions. Using bleach or any other chemicals/cleaners that do not state "pressure washer safe" can cause premature wear and damage to seals and o-rings. Continuous Water Source Requirement for Pressure Washers Q: Does my pressure washer require a continuous water source? A: Pressure washers require a continuous pressurized water source. If there is not adequate water to the pump, the unit will not operate correctly and the pump may sustain damage. Please check your Operator's Manual for the specific requirements of gallons per minute and psi for your unit. Pressure Washer Siphon Troubleshooting Q: How do I get the pressure washer to siphon? A: For basic operating instructions related to your specific pressure washer, please refer to your product Owner's Manual. Possible causes for lack of siphoning include: • Chemical hose placed on improper port -- Check clear hose placement. • Pressure washer is not set to low pressure --The unit must be set to low pressure to apply soap. Please be sure that the correct soap nozzle is being used. • Extension is being used on the high pressure hose -- Remove extension on high pressure hose. • Chemical injection area is clogged or component needs to be replaced -- Test for blockage: Remove nozzle extension from gun, attach and turn on water source, then pull the trigger.
    [Show full text]
  • PLUMBING DICTIONARY Sixth Edition
    as to produce smooth threads. 2. An oil or oily preparation used as a cutting fluid espe cially a water-soluble oil (such as a mineral oil containing- a fatty oil) Cut Grooving (cut groov-ing) the process of machining away material, providing a groove into a pipe to allow for a mechani cal coupling to be installed.This process was invented by Victau - lic Corp. in 1925. Cut Grooving is designed for stanard weight- ceives or heavier wall thickness pipe. tetrafluoroethylene (tet-ra-- theseveral lower variouslyterminal, whichshaped re or decalescensecryolite (de-ca-les-cen- ming and flood consisting(cry-o-lite) of sodium-alumi earthfluo-ro-eth-yl-ene) by alternately dam a colorless, thegrooved vapors tools. from 4. anonpressure tool used by se) a decrease in temperaturea mineral nonflammable gas used in mak- metalworkers to shape material thatnum occurs fluoride. while Usedheating for soldermet- ing a stream. See STANK. or the pressure sterilizers, and - spannering heat resistantwrench and(span-ner acid re - conductsto a desired the form vapors. 5. a tooldirectly used al ingthrough copper a rangeand inalloys which when a mixed with phosphoric acid.- wrench)sistant plastics 1. one ofsuch various as teflon. tools to setthe theouter teeth air. of Sometimesaatmosphere circular or exhaust vent. See change in a structure occurs. Also used for soldering alumi forAbbr. tightening, T.F.E. or loosening,chiefly Brit.: orcalled band vapor, saw. steam,6. a tool used to degree of hazard (de-gree stench trap (stench trap) num bronze when mixed with nutsthermal and bolts.expansion 2. (water) straightenLOCAL VENT.
    [Show full text]
  • Glossary of Terms — Page 1 Air Gap: See Backflow Prevention Device
    Glossary of Irrigation Terms Version 7/1/17 Edited by Eugene W. Rochester, CID Certification Consultant This document is in continuing development. You are encouraged to submit definitions along with their source to [email protected]. The terms in this glossary are presented in an effort to provide a foundation for common understanding in communications covering irrigation. The following provides additional information: • Items located within brackets, [ ], indicate the IA-preferred abbreviation or acronym for the term specified. • Items located within braces, { }, indicate quantitative IA-preferred units for the term specified. • General definitions of terms not used in mathematical equations are not flagged in any way. • Three dots (…) at the end of a definition indicate that the definition has been truncated. • Terms with strike-through are non-preferred usage. • References are provided for the convenience of the reader and do not infer original reference. Additional soil science terms may be found at www.soils.org/publications/soils-glossary#. A AC {hertz}: Abbreviation for alternating current. AC pipe: Asbestos-cement pipe was commonly used for buried pipelines. It combines strength with light weight and is immune to rust and corrosion. (James, 1988) (No longer made.) acceleration of gravity. See gravity (acceleration due to). acid precipitation: Atmospheric precipitation that is below pH 7 and is often composed of the hydrolyzed by-products from oxidized halogen, nitrogen, and sulfur substances. (Glossary of Soil Science Terms, 2013) acid soil: Soil with a pH value less than 7.0. (Glossary of Soil Science Terms, 2013) adhesion: Forces of attraction between unlike molecules, e.g. water and solid.
    [Show full text]
  • ME 262 BASIC FLUID MECHANICS Assistant Professor Neslihan Semerci Lecture 6
    ME 262 BASIC FLUID MECHANICS Assistant Professor Neslihan Semerci Lecture 6 (Bernoulli’s Equation) 1 19. CONSERVATION OF ENERGY- BERNOULLI’S EQUATION Law of Conservation of Energy: “energy can be neither created nor destroyed. It can be transformed from one form to another.” Potential energy Kinetic energy Pressure energy In the analysis of a pipeline problem accounts for all the energy within the system. Inner wall of the pipe V P Centerline z element of fluid Reference level An element of fluid inside a pipe in a flow system; - Located at a certain elevation (z) - Have a certain velocity (V) - Have a pressure (P) The element of fluid would possess the following forms of energy; 1. Potential energy: Due to its elevation, the potential energy of the element relative to some reference level PE = Wz W= weight of the element. 2. Kinetic energy: Due to its velocity, the kinetic energy of the element is KE = Wv2/2g 2 3. Flow energy(pressure energy or flow work): Amount of work necessary to move element of a fluid across a certain section aganist the pressure (P). PE = W P/γ Derivation of Flow Energy: L P F = PA Work = PAL = FL=P∀ ∀= volume of the element. Weight of element W = γ ∀volume W Volume of element ∀ = γ Total amount of energy of these three forms possessed by the element of fluid; E= PE + KE + FE P E = Wz + Wv2/2g + W γ 3 Figure 19.1. Element of fluid moves from a section 1 to a section 2, (Source: Mott, R. L., Applied Fluid Mechanics, Prentice Hall, New Jersey) 2 V1 P1 Total energy at section 1: E = Wz + W +W 1 1 2g γ 2 V2 P2 Total energy at section 2: E = Wz + W + W × 2 2 2g γ If no energy is added to the fluid or lost between sections 1 and 2, then the principle of conservation of energy requires that; E1 = E2 2 2 V1 P1 V2 P2 Wz + W +W = Wz + W + W × 1 2g γ 2 2g γ The weight of the element is common to all terms and can be divided out.
    [Show full text]
  • Pressure and Piezometry (Pressure Measurement)
    PRESSURE AND PIEZOMETRY (PRESSURE MEASUREMENT) What is pressure? .......................................................................................................................................... 1 Pressure unit: the pascal ............................................................................................................................ 3 Pressure measurement: piezometry ........................................................................................................... 4 Vacuum ......................................................................................................................................................... 5 Vacuum generation ................................................................................................................................... 6 Hydrostatic pressure ...................................................................................................................................... 8 Atmospheric pressure in meteorology ...................................................................................................... 8 Liquid level measurement ......................................................................................................................... 9 Archimedes' principle. Buoyancy ............................................................................................................. 9 Weighting objects in air and water ..................................................................................................... 10 Siphons ...................................................................................................................................................
    [Show full text]
  • Soap Lake Siphon
    ENGINEERING MONOGRAPHS No. E; . United States Department of the Interior BUREAU OF RECLAl\fATION SOAP LAKE SIPHON by ROBERT SAII.ER Denver, Colorado August 1950 4fj cents United States Department of the Interior OSCAR L. CHAPMAN, Secretary . Bureau of Reclamation MICHAEL W. STRAUS, Commissioner L. N. McCLELLAN, Chief Engineer Engineering Monographs No. 5 .SOAP LAKE SIPHON by Robert Sailer, Engineer, Canals Division . Branch of Design and Construction Technical Information Section Denver Federal Center · Denver, Colorado ENGINEERING. MONOGRAPHS are published in limited editions for the technical staff of the Bureau of Reclamation and interested technical circles in Government and private agencies. Their purpose is to record developments, innovations, and progress in the engineering and scientific techniques and practices that are employed in the planning, design, construction, and operation of Reclamation struc­ tures and equipment Copies may be obtained at 2~ from the Bureau of Reclamation, Denver Federal Center, Denver, Colorado, and Washington, D. C. FRONTISPIECE - Crossing the lower end of the Grand Coulee by the West Canal required construction of the Soap Lake Siphon. The siphon begins on the east aide of the depression (lower center), crosses at the north end of Soap Lake, and climbs the bench to the vest. FRONTISPIECE - Crossi.ng the lover end of the Grand Coulee by the West Canal required constructicin of the Soap Lake Siphon. The siphon begins on the east side of the depression (lover center), crosses at the north end of Soap Lake, and c11mba the bench to the vest. CONTENTS Page INTRODUCTION 1 INVESTIGATIONS 1 Lake Crossing 1 Final Location 3 ALTERNATIVE DESIGNS 5 Plan and Profile 5 Plate Steel Pipe · 5 Savings Possible with Steel-lined Pipe 5 DESIGN OF PIPE 7 General Description 7 Hydraulic Desigri 7 Gravel Trap 7 Inlet and Outlet Transitions 12 Concrete Pipe 13 Steel-lined Monolithic Concrete Pipe 17 1.
    [Show full text]
  • The Siphon and Understanding How Pressure Varies in a Pump System Jacques Chaurette April 2016
    The siphon and understanding how pressure varies in a pump system Jacques Chaurette April 2016 A siphon is a way of draining a tank at a high level from the top to another one at a lower level. The tank is not drained from the bottom but by a tube that exits the upper tank from the top and then turns downward to the lower tank. Or it could be from the side as long as one part of the tube goes above the liquid surface of the top tank. Surprisingly the liquid will move upward against gravity, a feat not possible in the world of solids. This is due to low pressure that keeps the liquid in the top part of the siphon from falling and the connection between fluid particles that pressure provides. Figure 1 Siphoning a liquid vs. moving a solid. Pressure in liquid systems is due to the weight of liquid above a surface. If we know the height and the density of the liquid we can calculate the pressure. Pressure is the same on any given horizontal plane and at any given point depends only on its vertical position with respect to some reference point. Pressure can also vary due to friction when the liquid is moving but in this case we can assume that the friction is very low since the liquid is moving slowly. Since the liquid is moving upwards it seems as if we are getting free energy, but we are not. While making the siphon we store positional or potential energy by lifting the fluid up in the top part of the siphon before it is set in motion.
    [Show full text]
  • The Height Limit of a Siphon
    www.nature.com/scientificreports OPEN The height limit of a siphon A. Boatwright1, S. Hughes2 & J. Barry2 The maximum height of a siphon is generally assumed to be dependent on barometric pressure— about 10 m at sea level. This limit arises because the pressure in a siphon above the upper reservoir Received: 03 March 2015 level is below the ambient pressure, and when the height of a siphon approaches 10 m, the pressure at the crown of the siphon falls below the vapour pressure of water causing water to Accepted: 14 October 2015 boil breaking the column. After breaking, the columns on either side are supported by differential Published: 02 December 2015 pressure between ambient and the low-pressure region at the top of the siphon. Here we report an experiment of a siphon operating at sea level at a height of 15 m, well above 10 m. Prior degassing of the water prevented cavitation. This experiment provides conclusive evidence that siphons operate through gravity and molecular cohesion. Although the siphon has been used since ancient times, the means of operation has been a matter of controversy1–6. Two competing models have been put forward, one in which siphons are considered to operate through gravity and atmospheric pressure and another in which gravity and liquid cohesion are invoked. Key evidence for the atmospheric model is that the maximum height of a siphon is approxi- mately equal to the height of a column of liquid that can be supported by the ambient barometric pres- sure. In this model, a siphon is considered to be two back-to-back barometers.
    [Show full text]
  • Experiment Instructions
    Experiment Instructions HM 160.36 Syphon Spillway 01/2000 HM 160.36 SYPHON SPILLWAY All Rights Reserved G.U.N.T. Gerätebau GmbH, Barsbüttel, Germany 05/1999 Experiment Instructions Please read and follow the instructions before the first installation! Publication-no.: 917.000 36 A 160 02 (A) 01/2000 , (DTP_2) , 05/1999 i 01/2000 HM 160.36 SYPHON SPILLWAY Table of Contents 1 Introduction . 1 2 Unit description . 2 2.1 Components . 2 2.2 Assembly. 2 3 Safety . 3 4 Theory and experiments . 4 4.1 The purpose and function of a siphon weir . 4 4.2 Experiment of the function of the siphon weir . 5 4.3 Calculating the outflow rate of a siphon weir . 6 4.4 Experiment to determine the outflow co-efficient of a siphon weir. 6 5 Appendix . 8 5.1 Technical Data . 8 5.2 Shape of the siphon . 8 All Rights Reserved G.U.N.T. Gerätebau GmbH, Barsbüttel, Germany 05/1999 ii 01/2000 HM 160.36 SYPHON SPILLWAY 1 Introduction The hydraulic processes on the Heyn siphon can be investigated with the accessory unit HM 160.36 si- phon spillway. Precise observations of the „start-up process“ and the surge phenomena which occur at the end of the siphon action can be made. A ventilation valve fitted at the top of the siphon al- lows a precise comparison to be made between the siphon action and the normal overflow weir. In addition, quantitative measurements of the flow rate capacity of the siphon and its overflow coeffi- cient can be determined.
    [Show full text]
  • Guideline for Use of Pumps and Siphons for Reservoir Drawdown Provides the Reader Information to Determine the Best Method to Employ for Reservoir Drawdown
    Guidelines for Use of Pumps Pum anandd SiSiphonsphons for EmergencyEmergency ReseReservoirrvoir DrawDrawdowndown DecemberDecember 20122012 GUIDELINES FOR USE OF PUMPS AND SIPHONS FOR EMERGENCY RESERVOIR DRAWDOWN DECEMBER 2012 Prepared by Morrison‐Maierle, Inc. TABLE OF CONTENTS Abstract ....................................................................................................................................................................................... 1 Introduction .............................................................................................................................................................................. 2 Overview of Pump Options ................................................................................................................................................. 4 Pumping System Components ...................................................................................................................................... 4 Pumping System Advantages ........................................................................................................................................ 7 Pumping System Disadvantages .................................................................................................................................. 8 Overview of Siphon Options .............................................................................................................................................. 9 Understanding Siphon Design Grades ......................................................................................................................
    [Show full text]
  • Siphon 100® Fill Plant Bulk Storage System – 100% of the Product 100% of the Time
    SIPHON 100® FILL PLANT BULK STORAGE SYSTEM – 100% OF THE PRODUCT 100% OF THE TIME Chart has engineered the Siphon 100® Bulk Storage Tank to provide an economical, reliable and high-performance storage system for pump filling high-pressure cylinders, liquid cylinders and transports. Current cryogenic tanks have worked for years, but increased efficiencies are now available with the Siphon 100 system allowing you to utilize 100% of the liquid contents. The Siphon 100 system combines two revolutionary technologies in cryogenic bulk tanks. Its improved “thermal-siphoning” system reduces and efficiently reprocesses the heat from pumping. Additionally, this system’s Composite Super Insulation™ is 30% to 70% more efficient than Perlite in reducing the effects of heat transfer from the atmosphere. PRODUCT ADVANTAGES • Thermal-siphon design manages heat from pump cool down, keeping storage tank pressure down • Simple and reliable automatic pump start-up in three minutes • Pump priming at tank pressure of 10 psi (0.69 bar) or less without the necessity for pressure building* • Vacuum insulated pod provides colder liquid to pump reducing cavitation • Extended legs add head pressure to pump without increasing liquid inventory for improved pump performance • Reduce liquid cylinder & Orca™ MicroBulk Delivery System filling losses • Longer life of high-wear pump parts • Capability to operate two pumps at once (liquid and HP pump) • Adapters available to match all standard pumps • Inner vessel designed and built to ASME Section VIII Division 1 code * Pump filling only. Add pressure builder if liquid filling large quantities from Siphon 100 tank. SIPHON 100® FILL PLANT BULK STORAGE SYSTEM – 100% OF THE PRODUCT 100% OF THE TIME Gross Capacity Net Capacity MAWP* Diameter Height Weight** NER % /day NER % /day Model Gal Liters Gal Liters psig bar in mm in mm lbs.
    [Show full text]