Building Services & Code Enforcement 451 South State Street, 215 PO Box 145490 Salt Lake City, UT 84114 www.slc.gov/buildingservices 801-535-6000 Updated 10-2012

Single Family Design Guidance

Unisex & bathrooms Unisex toilet Permitted locations Privacy In assembly and mercantile occupancies, an Unisex toilet rooms shall include only Unisex toilet and bathing rooms shall be located to unisex toilet and bathing rooms accessible unisex toilet room shall be provided one water and only one lavatory. A on an accessible route. Unisex toilet rooms shall shall be securable from within the room. where an aggregate of six or more male and female unisex bathing room in accordance with be located not more than one story above or water is required. In of mixed International code section 1109.2.1.3 below separate-sex toilet rooms. The accessible occupancy, only those water closets required shall be considered a unisex toilet room. rote from any separate-sex toilet room to a unisex Doors for the assembly or mercantile occupancy shall Exception: A urinal is permitted to toilet room shall not exceed 500 feet (152m). Doors shall not swing into the clear or be used to determine the unisex toilet room be provided in addition to the water ground space or clearance for any fixture. requirement. In recreational facilities where closet in a unisex toilet room. Exception: Where a clear floor or ground space separate-sex bathing rooms are provided, an Prohibited locations complying with the International Building accessible unisex bathing room shall be provided. In passenger transportation facilities and Code section 305.3 is provided within the Fixtures located within unisex toilet and bathing Unisex bathing rooms airports, the accessible route from separate- room, beyond the arc of the swing. rooms shall be included in determining the Unisex bathing rooms shall include only one sex toilet rooms to a unisex toilet room shall number of fixtures provided in an occupancy. shower or bathtub fixture. Unisex bathing rooms not pass through security checkpoints. Exception: Where each separate-sex bathing shall also include one water closet and one lavatory. Overlap room has only one shower or bathtub fixture, Where storage facilities are provided for separate- Clear floor or ground spaces, clearances, and a unisex bathing room is not required. Clear floor space sex bathing rooms, accessible storage facilities wheelchair turning spaces are permitted to overlap. shall be provided for unisex bathing rooms. Where doors swing into a unisex toilet or bathing room, a clear floor space not less than 30 inches by 44 inches (762mm by Water closet 1219mm) shall be provided, within the room, beyond the area of the door swing. The water closet shall be positioned with a to the rear and to one side. The centerline of the water closet shall be 16 inches by 18 inches (405mm by 455mm) maximum from the sidewall.