Fair Housing Act Design Manual
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Building an Adu
BUILDING AN ADU GUIDE TO ACCESSORY DWELLING UNITS 1 451 S. State Street, Room 406 Salt Lake City, UT 84114 - 5480 P.O. Box 145480 CONTENT 04 OVERVIEW 08 ELIGIBILITY 11 BUILDING AN ADU Types of ADU Configurations 14 ATTACHED ADUs Existing Space Conversion // Basement Conversion // This handbook provides general Home with Attached Garage // Addition to House Exterior guidelines for property owners 21 DETACHED ADUs Detached Unit // Detached Garage Conversion // who want to add an ADU to a Attached Above Garage // Attached to Existing Garage lot that already has an existing single-family home. However, it 30 PROCESS is recommended to work with a 35 FAQ City Planner to help you answer any questions and coordinate 37 GLOSSARY your application. 39 RESOURCES ADU regulations can change, www.slc.gov/planning visit our website to ensure latest version 1.1 // 05.2020 version of the guide. 2 3 OVERVIEW WHAT IS AN ADU? An accessory dwelling unit (ADU) is a complete secondary residential unit that can be added to a single-family residential lot. ADUs can be attached to or part of the primary residence, or be detached as a WHERE ARE WE? separate building in a backyard or a garage conversion. Utah is facing a housing shortage, with more An ADU provides completely separate living space people looking for a place to live than there are homes. including a kitchen, bathroom, and its own entryway. Low unemployment and an increasing population are driving a demand for housing. Growing SLC is the City’s adopted housing plan and is aimed at reducing the gap between supply and demand. -
Plugging Home Drains to Prevent Sewage Backup AE1476
NDSU EXTENSIONNDSU SERVICEEXTENSION SERVICE EXTENDINGEXTENDING KNOWLEDGE KNOWLEDGE CHANGING CHANGINGLIVES LIVES AE1476 AE-1476(Reviewed May 2018) Plugging Home Drains to Prevent Sewage Backup Why plug drains For homes in areas of the country prone to flooding or heavy rain, taking a few steps to prepare for water levels that could result in sewage backing up into a home makes sense. Sewage can enter a home a number of ways: • Sewage can flow back into homes if community treatment plants are flooded or even part of the sanitary sewer system is flooded. • In locations where the storm water and sewer systems are connected, rapid and excessive storm drainage can cause water and sewage to back up into your home. Check with your city officials to determine if your sewage system is connected to storm sewers. Prepare early • Septic systems in rural homes can back up into the home if the system is covered by water. The best advice is to prepare well in advance To reduce the possibility of sewage backing into a home, homeowners will need to seal areas where sewage can flow of any potential problems. in during periods of excessive rains or flooding. Sewage not only can damage building components and carpeting, Practice plugging each particular it also has high concentrations of bacteria, protozoans drain style so you can identify and other pathogens that can pose serious health risks. areas that might need Water will seek the lowest level, so if the level of sewage or floodwater is higher than the drains in the home, modifications before such as those in the basement, a backup can occur. -
NWP-2-235 Installing Drain Components Remove Drain PLUG (A) from FLANGE (B)
Installation Instructions Bidet Fittings Bidet with Drain Actuating Rods in front of Valves Model No. 2-235 Congratulations on the purchase of your Newport Brass product, an excellent choice, that will give you years of quality service and enhance the look and style of your home. Recommended installation by a Professional Plumbing Contractor Note: The use of petroleum base plumbers putty on our products will nullify the warranty. We recommend the use of clear silicone sealing materials. Installing Hot & Cold Valves The blue marked valve goes into the right side hole, the red marked valve goes into the left side hole. See Figure 1. Place flange NUT (1) and WASHER (2) on valve BODY (3). Insert valve BODY (3) from underside through hole in mounting surface at rear of bidet. Adjust valve to appropriate height above mounting surface to accomodate handle assembly. Using additional NUT (1) and WASHER (2) secure valve BODY (3) in place. Before tightening down flange NUT (1), check handle alignment and stem height by placing handle onto Valve (3). Any adjustments for rotational alignment must be made to the valve BODY (3), not to the cartridge. See Figure 2. Figure 1 Diverter Valve Figure 2 Vacuum Breaker 4 2 Cold Water 1 Hot Water Valve Valve 6 (RED) (BLUE) b 3 5 Pop-Up Outlet Knob/Rod 4 24” Hose to Douche Spray 1/2” NPSM Inlet 6 12” Supply Lines a c Installing Diverter Valve / Vacuum Breaker If unassembled, apply thread sealant to tapered end of ELBOW (7) and 14 19 connect to side outlet of diverter VALVE (11). -
6 Parkgate Street, Dublin 8, to the Record of Protected Structures in Accordance with Section 54 and 55 of the Planning and Development Act, 2000 (As Amended)
Conservation Section, Planning & Development Department Civic Offices, Wood Quay, Dublin 8 An Rannóg Caomhantais, An Roinn Pleanála agus Forbairt Maoine Oifigí na Cathrach, An Ché Adhmaid, Baile Átha Cliath 8 T. 01 222 3927 F. 01 222 2830 8th December 2020 (Revision A) To the Chairperson and Members of the Central Area Committee Initiation of the Statutory Process for the Proposed Addition of No.6 Parkgate Street, Dublin 8, to the Record of Protected Structures in accordance with Section 54 and 55 of the Planning and Development Act, 2000 (as amended). The initiation of the statutory addition process was agreed by the Central Area Committee of Dublin City Council at its monthly meeting on the 10th November 2020 PHOTOGRAPH OF STRUCTURE Introduction It is proposed to initiate procedures under Section 54 and Section 55 of the Planning & Development Act 2000 (as amended) to add ‘No.6 Parkgate Street, Dublin 8’ to Dublin City Council’s Record of Protected Structures. Proposal for Addition Minister for Culture, Heritage and the Gaeltacht on the 4th of June 2014. Request by Member of General Public on 17th of January 2019. Summary of Reasons for Seeking Addition Minister for Culture, Heritage and the Gaeltacht: List of recommendations for inclusion on the RPS of structures deemed as being of ‘Regional’ significance or higher identified during Stage 1 of the Dublin Survey carried out by the National Inventory of Architectural Heritage. No.6 Parkgate Street, Dublin 8, together with the neighbouring properties at Nos.7 and 8 Parkgate Street, Dublin 8 has been assigned a ‘Regional’ rating. -
Plumbing Guidelines for ADA Accessibility
Plumbing Guidelines for ADA Accessibility Course No: M01-004 Credit: 1 PDH Steven Liescheidt, P.E., CCS, CCPR Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 [email protected] Appendix A to Part 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities U.S. Architectural and Transportation Barriers Compliance Board (Access Board) 1331 F Street, N.W., Suite 1000 Washington, D.C. 20004-1111 (202) 272-0080 (202) 272-0082 TTY (202) 272-0081 FAX 4.16 Water Closets. mm) that allows a person in a wheelchair to make 4.16.1 General. Accessible water closets shall a parallel approach to the unit (see Fig. 27(c) and comply with 4.16.2 through 4.16.6. (d)). This clear floor space shall comply with 4.2.4. EXCEPTION: Water closets used primarily by children ages 12 and younger shall be permitted 4.16 Water Closets. to comply with 4.16.7. Fig. 27 Drinking Fountains and Water Coolers 45 4.17 Toilet Stalls. 4.16.2 Clear Floor Space. Clear floor space for bar centerline. The grab bar behind the water water closets not in stalls shall comply with Fig. closet shall be 36 in (915 mm) minimum. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach. EXCEPTION: If administrative authorities require flush controls for flush valves to be located in a 4.16.3* Height. -
Effective September 13, 2021
Managing the Office in the Age of COVID-19, effective September 13, 2021 Effective September 13, 2021 Page 1 Managing the Office in the Age of COVID-19, effective September 13, 2021 TABLE OF CONTENTS Summary ......................................................................................................................................... 3 Definitions ....................................................................................................................................... 4 Prepare the Building ....................................................................................................................... 5 Building Systems ........................................................................................................................................ 5 Cleaning ..................................................................................................................................................... 7 Access Control and Circulation .................................................................................................................. 7 Prepare the Workspace ................................................................................................................ 10 Cleaning ................................................................................................................................................... 10 Prepare the Workforce ................................................................................................................. 12 Scheduling ............................................................................................................................................... -
Go Before You Go: How Public Toilets Impact Public Transit Usage
PSU McNair Scholars Online Journal Volume 8 Issue 1 The Impact of Innovation: New Frontiers Article 5 in Undergraduate Research 2014 Go Before You Go: How Public Toilets Impact Public Transit Usage Kate M. Washington Portland State University Follow this and additional works at: https://pdxscholar.library.pdx.edu/mcnair Part of the Social Welfare Commons, Transportation Commons, and the Urban Studies and Planning Commons Let us know how access to this document benefits ou.y Recommended Citation Washington, Kate M. (2014) "Go Before You Go: How Public Toilets Impact Public Transit Usage," PSU McNair Scholars Online Journal: Vol. 8: Iss. 1, Article 5. https://doi.org/10.15760/mcnair.2014.46 This open access Article is distributed under the terms of the Creative Commons Attribution-NonCommercial- ShareAlike 4.0 International License (CC BY-NC-SA 4.0). All documents in PDXScholar should meet accessibility standards. If we can make this document more accessible to you, contact our team. Portland State University McNair Research Journal 2014 Go Before You Go: How Public Toilets Impact Public Transit Usage by Kate M Washington Faculty Mentor: Dr. James G. Strathman Washington, Kate M. (2014) “Go Before You Go: How Public Toilets Impact Public Transit Usage” Portland State University McNair Scholars Online Journal: Vol. 8 Portland State University McNair Research Journal 2014 Abstract The emphasis on sustainable solutions in Portland, Oregon includes developing multi-modal transportation methods. Using public transit means giving up a certain amount of control over one’s schedule and taking on a great deal of uncertainty when it comes to personal hygiene. -
120' Raised Pilothouse Motor Yacht
THIS DOCUMENT IS THE INTELLECTUAL PROPERTY OF BURGER BOAT COMPANY AND GREGORY C. MARSHALL N.A. LTD. AND CONTAINS PROPRIETARY INFORMATION. IT SHALL NOT BE USED OR REPRODUCED IN WHOLE OR IN PART NOR SHALL IT BE DISCLOSED TO PARTICIPANTS OF THE YACHTING INDUSTRY WITHOUT THE EXPRESS WRITTEN CONSENT OF BURGER BOAT COMPANY. R 2 x 20 PERSON LIFE RAFTS 20' NOVURANIA STEP STEP HOT TUB LOOSE FURNITURE CATAMARAN SETTEE TENDER STEP SEA-DOO GTX-LTD STEP FULL BEAM SEAT/ STEP LOUNGE STEP WITH POP UP DAVIT SLIDING HATCH TO UNDER LIFT UP HATCH TO BRIDGE TWEEN-DECK STORAGE DAY HEAD WET W/FROSTED BAR FLYBRIDGE HELM OPTIONAL SKYLIGHT FRIDGE SETTEE BBQ 2 x 20 PERSON LIFE RAFTS 2'-8" 45 40 35 30 25 20 15 10 5 0 2 x 20 PERSON LIFE RAFTS BRIDGE & SUN DECK WING BRIDGE DOWN TO STEP MAIN DECK TECHNICAL SPACE STEP STEP SLIDING DOOR STEP SHOWN OPEN LOCKER STEP SETTEE STEP STEP STEP TABLE STEP SETTEE STEP FULL BEAM STEP SUNPAD SEAT/ SETTEE TABLE STEP ANCHOR LOUNGE HANDLING STEP WITH POP UP TO FLYBRIDGE UP DAVIT UNDER STEP WATER TOY STORAGE BRIDGE DOWN TO MAIN DECK DOWN TO DAY AFT DECK STEP HEAD STEP OPEN TO PASSAGEWAY BELOW LOCKER SLIDING DOOR STEP SHOWN CLOSED STEP STEP TECHNICAL SPACE DOWN TO STEP MAIN DECK WING BRIDGE 2 x 20 PERSON LIFE RAFTS 2'-8" 45 40 35 30 25 20 15 10 5 0 SIDE GATE WEATHER ENCLOSURE MAIN DECK TV UP TO BRIDGE DECK GARBAGE Trash Trash BAR/BUFFET STORAGE UNDER Bin Bin UP TO DOWN TO DRESSER SWIM DECK AFT DECK MACHINERY Above Cabinets DRESSER DRESSER TC DRESSER SPACE TC AIR Oven DW WALK-IN END TABLE END TABLE WARDROBE SOFA Cooktop Exhaust Hood Above CHAIR 40 K.W. -
Single Family Housing Design Standards
TEXAS GENERAL LAND OFFICE COMMUNITY DEVELOPMENT AND REVITALIZATION HOUSING DESIGN STANDARDS (SINGLE FAMILY) Revised July 21, 2020 TEXAS GENERAL LAND OFFICE COMMUNITY DEVELOPMENT AND REVITALIZATION DIVISION GLO-CDR HOUSING DESIGN STANDARDS (SINGLE FAMILY) The purpose of the Texas General Land Office Community Development and Revitalization division’s (GLO-CDR) Housing Design Standards (the Standards) is to ensure that all applicants (single family housing applicants) who receive new or rehabilitated construction housing through programs funded through GLO-CDR live in housing which is safe, sanitary, and affordable. Furthermore, these Standards shall ensure that the investment of public and homeowner funds results in lengthening the term of affordability and the preservation of habitability. All work carried out with the assistance of funds provided through GLO-CDR shall be done in accordance with these Standards and the GLO-CDR Housing Construction Specifications as they apply to single family housing applicants and, unless otherwise defined, shall meet or exceed industry and trade standards. Codes, laws, ordinances, rules, regulations, or orders of any public authority in conflict with installation, inspection, and testing take precedence over these Standards. A subrecipient can request a variance for any part of these Standards for a specific project by submitting a written request to GLO-CDR detailing the project location, the need for the variance, and, if required, the proposed alternative. Variance requests can be submitted to: Martin Rivera Jerry Rahm Monitoring & QA Deputy Director Housing Quality Assurance Manager Community Development and Community Development and Revitalization Revitalization Texas General Land Office Texas General Land Office Office 512-475-5000 Office 512-475-5033 [email protected] [email protected] 1700 North Congress Avenue, Austin, Texas 78701-1495 P.O. -
Recode Draft Plumbing Code for Composting and Urine Diversion Toilets
June 9, 2014 Recode Draft Plumbing Code for Composting and Urine Diversion Toilets Editor Mathew Lippincott recodeoregon.org Collaborators Laura Allen greywateraction.org Mark Buehrer 2020engineering.org Molly Danielsson recodeoregon.org Melora Golden recodeoregon.org Colleen Mitchell 2020engineering.com Kim Nace richearthinstitute.org Glenn Nelson compostingtoilet.com Abe Noe-Hayes richearthinstitute.org David Omick watershedmg.org/soil-stewards John Scarpulla sfwater.org Justification Introduction Water scarcity and pollution concerns are driving Environmental Protection: the adoption of composting and urine diversion Urine diversion can reduce nitrogen in domestic toilet systems in the US and abroad. In the US, wastewater by 80%, and Composting Toilet these systems have been treated unevenly by Systems can reduce household nitrogen by close a patchwork of regulations in Health, Onsite to 90%, both at installed costs of $3-6,000. This is Sanitation, and Building Code departments a higher performance than Alternative Treatment because they do not fit neatly into categories Technologies (ATTs) and sand filters currently designed to guarantee safe sanitary drainage required in many jurisdictions with surface and systems. It is the opinion of this code group that groundwater concerns, and at a fraction of the composting and urine diversion toilets are at a cost. This code brings new, lower cost options for turning point, mature enough to build sound environmental protection to homeowners. regulation around while also being a site of active research and development. Our intent is Innovation: therefore to create code language that provides This code enables the installation of innovative for strict protections on public health while also technologies by creating a code with clear encouraging the growth of domestic industry and inspection points to safeguard public health even innovation in composting and urine diversion in the event of the failure of new or experimental systems. -
Surface-Mounted Toilet Tissue Cabinet Shall Be Type-304 Stainless Steel with Satin Finish
SURFACE-MOUNTED TOILET TISSUE B-272 Technical Data CABINET 3-1/4'' Finish Face of Wall 65mm 7/8'' Lock & Key 22mm S 6'' 150mm 8-15/16'' 225mm 28'' 710mm S Recommended Mounting Height Off Floor 5'' 3'' 125mm 75mm MATERIALS: Cabinet — 18-8, type-304, 22-gauge (0.8mm) stainless steel with satin finish. Equipped with a tumbler lock keyed like other Bobrick washroom accessories. OPERATION: Unit dispenses either single- or doublefold toilet tissue. Large capacity accommodates 1330 singlefold toilet tissues and can be refilled with a full standard pack before dispenser is empty. Slots in cabinet indicate refill time. INSTALLATION: Mount unit on wall or partition with four #8 x 3/4" (4.5 x 19mm) sheet-metal screws (not furnished) at points indicated by an S. For plaster or dry wall construction, provide concealed backing to comply with local building codes, then secure unit with sheet-metal screws. For other wall surfaces, provide fiber plugs or expansion shields for use with sheet-metal screws or provide 1/8" (3mm) toggle bolts or expansion bolts. SPECIFICATION: Surface-mounted toilet tissue cabinet shall be type-304 stainless steel with satin finish. Unit shall dispense either single- or doublefold toilet tissue and be equipped with a tumbler lock keyed like other Bobrick washroom accessories. Surface-Mounted Toilet Tissue Cabinet shall be Model B-272 of Bobrick Washroom Equipment, Inc., Clifton Park, New York; Jackson, Tennessee; Los Angeles, California; Bobrick Washroom Equipment Company, Scarborough, Ontario; Bobrick Washroom Equipment Pty. Ltd., Australia; and Bobrick Washroom Equipment Limited, United Kingdom. The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. -
Housing Standards Review
Housing Standards Review Illustrative Technical Standards Developed by the Working Groups August 2013 Department for Communities and Local Government © Crown copyright, 2013 Copyright in the typographical arrangement rests with the Crown. You may re-use this information (not including logos) free of charge in any format or medium, under the terms of the Open Government Licence. To view this licence, www.nationalarchives.gov.uk/doc/open- government-licence/ or write to the Information Policy Team, The National Archives, Kew, London TW9 4DU, or email: [email protected]. This document/publication is also available on our website at www.gov.uk/dclg If you have any enquiries regarding this document/publication, email [email protected] or write to us at: Department for Communities and Local Government Eland House Bressenden Place London SW1E 5DU Telephone: 030 3444 0000 For all our latest news and updates follow us on Twitter: https://twitter.com/CommunitiesUK August 2013 ISBN: 978-1-4098-3974-3 Contents Standard 1: Accessibility 4 Standard 2: Space 46 Standard 3: Domestic Security 62 Standard 4: Water Efficiency 87 Standard 5: Energy 91 The proposals in this technical annex document have been assembled by the working groups and are illustrative, to inform debate. They are not Government policy. 3 Standard 1: accessibility Contents Introduction Requirements Part I: Approach Routes, Communal Entrances and Communal Facilities 1.0 Approach routes 2.0 Car-parking 3.0 Communal entrances 4.0 Communal lifts and stairs Part