HABL SCOPE OF ACCREDITATION

laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad. Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

last Amended on 10.10.2016 Page 1 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

I. POWER CAPACITORS

1. ACMotor Visual Examination IS 2993: 1998 (RA 2006) Qualitative Capacitors Clause. 2.6 Upto 25 MF Checking Marking IS 2993: 1998 (RA 2006) Qualitative Clause. 5.1

Check of Dimension IS 2993: 1998 (RA 2006) 1 mmt0250mm Clause. 2.10

Mechanical Test. IS 2993: 1998 (RA 2006) I Nto20N Clause. 2.11

Sealing Test IS 2993: 1998 (RA 2006) 20 'C to 100 'C Clause. 2.12

Endurance Test IS 2993: 1998 (RA 2006) 1 flfd to 20 "fd Clause. 2.13

Soldering Test IS 2993: 1998 (RA 2006) Qualitative Clause. 2.11.2

Damp Heat Test IS 2993: 1998 (RA 2006) 60 % to 95 % Humidity Clause. 2.14 At 40 °C

Voltage Test Between IS 2993: 1998 (RA 2006) IVtolooOV Terminals Clause. 2.7

Voltage Test Between IS 2993: 1998 (RA 2006) I kV to 6 kV Terminals & Case Clause. 2.8

Self Healing Test IS 2993: 1998 (RA 2006) lOVto 1500V Clause. 2.15

\!-sl1ok Kumar N. Venkateswaran Convenor nABL SCOPE OF ACCREDITATION

laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 2of34

S.No. Product f Specific Test Performed Test Method SpeCification Range of Testing f Material of Test againat which tests are Lim Its of Detection !!erformed

ACMoior Destruction Test IS 2993: 1998 (RA 2006) Qualitative Capaeilors Clause. 2.16 Uplo 2SMF Measurement of Capacitance IS 2993: 1998 (RA 2006) 1 "fd to 80 "fd Clause. 2.9

Tangent of Loss Angle IS 2993: 1998 (RA 2006) oto 0.01 Clause. 2.5

2. Capa

Check ofDimension IS 1709: 1984 (RA 2006) 1 mm to 250 mm Amd. 1 &2 Clause. 1.1

Mechanical Test. IS 1709: 1984 (RA 2(06) 1 Nt020N Amd. 1 &2 Clause. 7.7-7.11

Sealing Test IS 1709: 1984 (RA 2006) 20'C to 100'C Amd.l &2 Clause. 7.12

Endurance Test IS 1709: 1984 (RA 2006) J "fd to 20 "fd Amd. 1&2 Clause. 7.16

Soldering Test IS 1709: 1984 (RA 2006) Qualitative Amd.l &2 Clause. 7.11

shokKumar N. Venkateswaran Convenor Program Manager HABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.). Kamla Nehru Nagar. Ghaziabad. Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 3 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

Capadtor for Damp Heat Test IS 1709: 1984 (RA 2006) 65 % 10 95 % Humidity Electric Fan Amd.l &2 5"C to 60 "C Motors Clause. 7.15 Upto15 MF Insulation Resistance IS 1709: 1984 (RA 2006) I MOto I m (Terminals & Conlainer) Amd.l&2 At 500V Clause. 7.3.1

Insulation Resistance IS 1709: 1984 (RA 2006) IMfl to 1 TO Between Terminals Amd.l &2 At 500V Clause. 7.3.2

Voltage Test Between IS 1709: 1984 (RA 2006) 1 VlolOOOV Terminals Amd. 1 & 2 Clause. 7.4.1

Voltage Test Between IS 1709: 1984 eRA 2006) I kVt06kV Terminals &Case Amd. I & 2 Clause. 7.4.2

Self Healing Test IS 1709: 1984 (RA 2006) lOVto1500V Amd.1 &2 Clause. 7.14

Destruction Tesl IS 1709: 1984 (RA 2(06) Qualitative Amd.l &2 Clause. 7.17

Measurement of Capacitance IS 1709: 1984 (RA 2006) I !lfd to 80 IlFd & Tan 6 Amd. I & 2 min 0.00001 Clause. 7.13

shok Kumar N. Venkateswaran Convenor Program Manager SCOPE OF"ABL ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEe 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 40f34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

3. Capacitor for Visual Examination IS 1709: 1984 (RA 2006) Qualitative Electric Fan Amd. 1 & 2 Motors Clause. 5,4 Amd.l&2 Upto25MF Sealing & Heating Test IS 1709: 1984 (RA 2006) 27 'C to 100 'C (*)5 'C Amd.l&2 Clause. 5.5

Voltage Proof Test IS 1709: 1984 (RA 2006) 010IOOOV*5% Amd.l &2 0106kV*5% Clause. 5.6

Voltage Test Between Case IS 1709: 1984 (RA 2006) 1 V 10 1000 V (*)5 % . Amd.l & 2 1 kV to 6 kV (±)5 % Clause. 5.7

Capacitance Measurement IS 1709: 1984 (RA 2006) 10VtolOOOV Test Amd. 1 & 2 1 "fd to 80 "Fd Clause. 5.8

Discharge Resister Test IS 1709: 1984 (RA 2006) Qualitative Amd.1&2 Clause. 5.9

Thennal Stability Test IS 1709: 1984 (RA 2006) 27 'Cto 300'C Amd.l&2 Clause.SJO

Self Healing Test IS 1709: 1984 (RA 2006) 10 V to 1500V Amd.l &2 Clause. 5.11

Damp Heat Test IS 1709: 1984 (RA 2006) 1 % to 98 % Humidity Amd.I&2 At 40 °C Clause. 5.12

N. Venkateswaran Convenor Pro ram Mana er HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 5 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection eerformed

CapacitOlr fOlr Endurance IS 1709: 1984 (RA 2006) 100 ·C,IOOO V,50 Hz Electric Fan Amd.l &2 Motor. Clause. 5.13 Amd.l&2 Upto25MF Destruction Test IS 1709: 1984 (RA 2006) Qualitative Amd.1 &2 Clause. 5.14

4. Capacitor For Visual Examination IS 1569: 1976 (RA 2001) Qualitative Fluorescent Amd.1 Lamp Clause. 5.4 Upt025MF Scaling & Heating Test IS 1569: 1976 (RA 2001) 27 ·Cto 100 ·C±.5·C Amd.l Clause. 5.5

Voltage Proof Test IS 1569: 1976 (RA 2001) oto 1000 V (±) 5 % Amd.1 oto 6 kV (±)S % Clause. 5.6

Voltage Test Between Case IS 1569: 1976 (RA 2001) oto 1000 V (±)5 % Amd.l oto 6 kV (±)5 % Clause. 5.7

Capacitance Measurement IS 1569: 1976 (RA 2001) Oto 1000 V Test Amd.l I I1fd to 80 IIFd Clause. 5.8

Discharge Resister Test IS 1569: 1976 (RA 2001) Qualitative Amd.1 Clause. 5.9

Thermal Stability Test IS 1569: 1976 (RA 2001) 27·C to 300· C Amd.l Clause. 5.10

s ok Kumar N. Venkateswaran Convenor Program Manager "ABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I. Kamla Nehru Nagar. Ghazlabad. Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Untlt 11.08.2018

Last Amended on 10.10.2016 Page 60f34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Capacitor For SelfHealing Test IS 1569: 1976 (RA 2001) Oto 1500 V Fluorescent Amd.1 Lamp Clause. 5.11 Upto2SMF Damp Heat Test IS 1569: 1976 (RA 2001) 1 % to 98 % Humidity Amd.l AI400C Clause. 5.12

Endurance IS 1569: 1976 (RA 200 I) 100 'C.1000 V,50 Hz Amd.1 Clause. 5.13

Destruction Test IS 1569: 1976 (RA 2001) Qualitative Amd.l Clause. 5.14

II. TRANSFORMERS AND REACTORS

1. Distribution & Lighting Impulse Voltage Test IS 2026 (Part 3): 2009 20 kV to 1400 kV Power Clause. 13 & 14 Peak Distribution IS 3156: 1992 Clause. 9.6 Tl: 1.2 lIS Transformer. IS 2075: 1992 Clause. 9.8 T2: 50 f.ts Current Transformers Winding Resistance IS 11 80: 2014 1 mO to 10000 Potentlal lEC 60076: 2011 Transformers IS 11171: 1985 Reactors (Transformer of Voltage Ratio & Voltage IS 1180: 2014 2 turns 10 2000 turns upto 33KV,20 Vector Group Test lEC 60076: 2011 All vector group as per of MVA;CT,PTupto IS 11171: 1985 lEC 60076-1 : 2001 400KV) Annexure D

No Load & Current IS 1180:2014 Uplo I MVA IEC 60076: 2011 110 V to 2 kV IS 11171: 1985 (10 W to 100 kW)

A hokKumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016 Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 70f34 S.No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection I!erformed

Distribution & Short Ckt Impedance & Load IS 1180: 2014 10WtoiookW Power Loss IEC 60076: 2011 Impedance Upto 50 % Distribution IS 11171: 1985 Transformers Current Insulation Resistance IS 1180: 2014 lrotolOTll Transformers IEC 60076: 2011 500 V to 5000 V DC Potential [S 11171: 1985 Transformers Reactors Temperature Rise IS 1180:2014 Loss: 10 W to 100 kW (Transformer of IEC 60076: 2011 Temp. 1"C to 200 ·C uplo 33KV ,20 [S I1l71: 1985 MVAjCT,PT upto 400KV) Induced AC Voltage Test IS 1180:2014 300 V to 900 V, IEC 60076: 2011 100Hz IS 11171: 1985

Separate Source AC IS 1180: 2014 1 kV to 125 kV rms AC, Withstand Voltage Test IEC 60076: 2011 50 rnA, IS 11171: 1985 50kV,200mA

2. Insulating Oil Break Down Voltage IS 335: 1993 1 kV to 65 kV (AC) Electric.1 IS 1866: 2000 Materia[- Liquid IS 6792: 2008 Di.[eotic material

III. DOMESTIC ELECTRICAL APPLIANCES

1. Self contained Insulation Resistance Test IS 1475 (Part 1): 2001 1 Mnto I Tn drinking water (RA 2007) Clause. 7.7.1 cooler (Upto 200 Litre.) Higb Voltage Test IS 1475 (Part I): 2001 0.5 kV 104 kV (RA 2007) Clause. 7.7.2

Cooling Capacity Rating Test IS 1475 (Part I): 2001 1 UrlHr to 150 Uri Hr (RA 2007) Clause. 7.7.3 1°C to 100·C

S okKumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 80f34

S.No. Product I Specific Test Performed Test Method Specification Range of Testing I MaterlalofTest against which tests are Limits of Detection performed

Self contained Maximum Operating IS 1475 (Part I): 2001 j·Cto 100·C drinking water Condition Test (RA 2007) cooler Clause. 7.7.4 (Upto 200 Lltres) Storage Capacity Test IS 1475 (Part I): 2001 0.1 I to 150 I (RA 2007) Clause. 5.6.2

Input Current IS 1475 (Part I): 2001 0.1 A to 20 A (RA2oo7) Clause. 7.7.3

Power Consumption IS 1475 (Part I): 2001 0.5 W to 2000 W (RA 2007) Clause. 7.7.3

2. Electric Air Delivery 18374: 1979 (RA 2005) 50 m'/h to 500 m'/h Ceiling Fan Amd.1 to 6 Clause. 10.3

Temperature Rise IS 374: 1979 (RA 2005) O·Cto 150·C Amd.llo 6 Clause. 10.4

Leakage Current IS 374: 1979 (RA 2005) 0.4 ~ to 500 ~A Amd. I to 6 Clause. j 0.5

High Voltage IS 374: 1979 (RA 2005) 0.5 kVto4 kV Amd.lto6 Clause. 10.6

Insulation Resistance IS 374: 1979 (RA 2005) lMntolTn Amd, 1 t06 At 500V Clause. 10.7

~ ~--- hokKumar N. Venkateswaran Convenor Program Manager HfiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar. Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 90f34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

EIKlrlc Starting IS 374: 1979 (RA 2005) 0.5 V to 300 V Ceiling Fan Amd.ll06 Clause. 10.8

Fan Speed & Input IS 374: 1979 (RA 2005) 0.5 W to 1000 W Amd. I t06 0.1 rpm to 2000 rpm

Earthing Conneetion IS 374: 1979 (RA 2005) O.H!to JOn Amd. 1 to 6 Clause. 10.10

Protective Against IS 374: 1979 (RA 2005) Qualitative Electric Shock Amd. 1 t06 Clause. 10.11

MoisttJre Resistance IS 374: 1979 (RA 2005) 1MntolOGn (For Regulators Only) Amd. 1 to 6 Clause. 10.12

Mechanical Strength IS 374: 1979 (RA 2005) 0.35,0.5,0.7 Nm (For Regulators Only) Amd. 1 to 6 Clause. 10.13

Suspension System IS 374: 1979 (RA 2005) oto 1000 kN Amd. 1 to 6 Clause. 10.14

Creepage Distance & IS 374: 1979(RA2005) Oto 250 mm Clearances Amd. 1 to 6 Clause. 10.15

Mechanical Endurance IS 374: 1979 (RA 2005) Qualitative (For Regulators Only) Amd. 1 t06 Clause. 10.16

~~. ~Ashok Kumar N. Venkateswaran Convenor Program Manager HfiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 10 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

3. Propeller Type Starting Test IS 2312: 1967 (RA 2005) 0.5 V to 300 V AC Ventilating Amd.8 Fans (lJpto Clause. 10.1 IiOO mm sweep Air Delivery Test IS 2312: 1967 (RA 2005) I m'lh to 1000 m'lh Amd.8 Clause. 14.2

Temperature Rise IS 2312: 1967 (RA 2005) 1 'C to 150 'C Amd.8 Clause. 14.3

Power Factor IS 2312: 1967 (RA 2005) 0.1 to 1 Amd.8 Clause. 14.4

ACLeakage IS 23 I2: 1967 (RA 2005) 0.1 itA to 500 itA Amd.8 Clause. 14.7

High Voltage IS 2312: 1967 (RA 2005) 0.5 kVt04 kV Amd.8 Clause. 14.6

Insulation Resistance IS 2312: 1967 (RA 2005) IMfl·ITfl Amd.8 At500V Clause. 14.9

Earth Continuity IS 2312: 1967 (RA 2005) O.ll1flto 10fl Amd.8 Clause. 14.10

Electrical Input IS 2312: 1967 (RA 2005) 0.5 W to 1000 W Amd.8 Clause. 14.1 I

shok Kumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025; 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

last Amended on 10.10.2016 Page 11 of 34

S. No. Product! Specific Test Performed Test Method Specification Range of Testing! Material of Test against which tests are Limits of Detection performed

Propeller Type Fan Speed IS 2312: 1967 (RA 2005) 1 rpm to 2000 rpm AC Vendlating Amd.8 Fans (Upto Clause, 14,12 600mm sweep Moisture Proof Test (For IS 2312: 1967 (RA 2005) 0,5 kV t04 kV Regulators Only Amd.8 1 Mnto 10 GO, Clause. 14,4 RH:1O%to98%

4. Instantaneous Protection Against Eleetric IS 8978: 1992 (RA 2009) Qualitative Water Heater Shock Amnd.2 IS 302·2·35: 1993 (RA 2011) Clause 8

Input IS 8978: 1992 (RA 2009) 0.1 kW to 4 kW Amnd.2 IS 302·2·35: 1993 (RA 2011) Clause 10

Temperature Rise IS 8978: 1992 (RA 2009) Ambient 150 'C Amnd.2 IS 302·2·35: 1993 (RA 2011) Clause JI

Eleetrical Insulation And IS 8978: 1992 (RA 2009) IMntolTn Leakage Current Amnd,2 IS 302·2·35: 1993 (RA 2011) Clause 13

Moisture Resistance Test IS 8978: 1992 (RA 2009) 1 MOto lOGO Amnd.2 IS 302·2·35: 1993 (RA20Jl) Clause 15

Endurance Test IS 8978 Clause 12.1 IMOtolTn At 500V

~. ~>v--

AS ok Kumar N. Venkateswaran Convenor Program Manager HfiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

last Amended on 10.10.2016 Page 12 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Instantaneous Abnonnal Operation Test IS 8978: 1992 (RA 2009) 0.5 leV to 5 kV, Water Heater Amnd.2 IS 302·2·35; 1993 (RA 2011) Clause 19.2

Stability and Mechanical IS 8978: 1992 (RA 2009) Qualitative Hazard Amnd.2 IS 302·2-35: 1993 (RA 20ll) Clause 20

Mechanical Test IS 8978: 1992 (RA 2009) 0.35,0.5,0.7 Nm Amnd.2 IS 302·2·35: 1993 (RA 2011) Clause 21

Construction IS 8978: 1992 (RA 2009) Qualitati ve Amnd.2 IS 302·2·35: 1993 (RA 20ll) Clause 22

Internal Wiring IS 8978: 1992 (RA 2009) Qualitative Amnd.2 IS 302·2·35: 1993 (RA 2011) Clause 23

Components IS 8978: 1992 (RA 2009) Qualitative Amnd.2 IS 302-2·35: 1993 (RA 2011) Clause 24

Supply Connection and IS 8978: 1992 (RA 2009) (0 to 25m Flexible Cord Amnd.2 LC (*).001 mm IS 302·2·35: 1993 (RA 2011) Clause 25

As ok Kumar N. Venkateswllran Conl/enor Program Manager • t1f1BL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005 Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 13 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I MaterlaLof Test against which tests are limits of Detection performed

Instantaneous External Conductor IS 8978: 1992 (RA 2009) 0.1 mm to 150 mm WalerHeater Amnd.2 IS 302-2-35: 1993 (RA 2011) Clause 26

Earthling Connection IS 8978: 1992 (RA 2009) 0.1 n to 10 n Amnd.2 IS 302-2-35: 1993 (RA 2011) Clause 27

Screw & Connection IS 8978: 1992 (RA 2009) 0.5 mm to 250 mm Amnd.2 IS 302-2-35: 1993 (RA 2011) Clause 28

Creepage Distance And IS 8978: 1992 (RA 2009) 0.5 mm to 250 mm Clearance Amnd.2 IS 302-2-35: 1993 (RA 2011) Clause 29

Test For Resistance to Heat IS 8978: 1992 (RA 2009) 0.5 mm to 150 mm And Fire Amnd.2 (Ball pressure test) IS 302-2-35: 1993 (RA 2011) Clause 30

Resistance to Rusting IS 8978: 1992 (RA 2009) Qualitative Amnd.2 IS 302-2-35: 1993 (RA 2011) Clause 31

Finish IS 8978 Clause 10.1 Qualitative

Operation of Flow Switch IS 8978 Clause II Qualitative

~-' As ok Kumar N. Venkat8$waran Convenor Program Menager SCOPE OF"ABL ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accred Itation Standa rd ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 140f34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Teet against which tests are Limits of Detection performed

Instantaneous Supply Connection and IS 8978: 1992 (RA 2009) oto 25 mm Water Heater Flexible Cord Amnd.2 LC±ROOI mm IS 302-2-35: 1993 (RA 2011) Clause 25

5. Electric Protection Against Electric IS 368: 1992 Amnd. 1 Qualitative immersion Water Shock IS 302-2-201: 2008 Clause 8 Heater Input IS 368: 1992 Amnd. I 0.1 kW to 4 kW IS 302·2-201; 2008 Clause 10

Temperature Rise IS 368: 1992 Amnd. I Ambient (-) 150'C IS 302·2-201: 2008 Clause 11

Operation Under Over Load IS 368: 1992 Amnd. I 0.5 kW to 5 kW Condition IS 302-2-201: 2008 Clause 12

Electrical Insulation And IS 368: 1992 Amnd. 1 I M n to 1 Tn Leakage Current IS 302·2-201: 2008 Clause 13

Moisture Resistance Test IS 368: 1992 Amnd. liMnto 10 Gn IS 302·2-201: 2008 Clause 15

Insulation Resistance And IS 368: 1992 Amnd. liMnto 1 Tn Electric Strength IS 302·2-201; 2008 Clause 16

Abnonnal Operation Test IS 368: 1992 Amnd. 1 0.5 kV to 5 kV, IS 302·2·201: 2008 Clause 19.2

Stability and Mechanical IS 368: 1992 Amnd. I Qualitative Hazard 18302-2·201: 2008 Clause 20

Mechanical Strength IS 368: 1992 Amnd. I 0.35,0.5,0.7 Nm IS 302·2-201: 2008 Clause 21

A hokKumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 15 of 34

S. No. Product I Specific Test Performed Test Method SpeCification Range of Testing I Malerial ofTest against which tests are limits of Detection E!erformed

Electric Construction IS 368: 1992 Amnd. I Indicating lamp Volt 60 V, immersioD Water IS 302-2-201: 2008 Clause 22 75N neater Internal Wiring IS 368: 1992 Amnd. I Qualitative IS 302-2·201: 2008 Clause 23

Components IS 368: 1992 Amnd. 1 Qualitative IS 302-2-201: 2008 Clause 24

Supply Connection And IS 368; 1992 Amnd. I (01025 m Flexible Cord IS 302-2-201: 2008 Clause 25 LC (±).001 mm (0.1 m to 150 m LC: (±) om mm

Terminal For External IS 368: 1992 Amnd. 1 0.1 mm to 150mm Conductor IS 302-2-201: 2008 Clause 26

Eanhling Connection IS 368: 1992 Amnd. 1 0.1 ntolOn IS 302-2-201: 2008 Clause 27

Screw and Connection, IS 368: 1992 Amnd. 1 0.1 mm to 250 mm IS 302-2-201: 2008 Clause 28,29,30

Creepage Distance and IS 368; 1992 Amnd. 1 0.1 mm to 250 mm Clearance IS 302-2-201: 2008 Clause 30

Test For Resistance to Heat IS 368: 1992 Amnd. 1 0.1 mm to ISO mm And Fire IS 302-2-201: 2008 Clause 31 (Ball Pressure Test)

Resistance to Rusting IS 368; 1992 Amnd. 1 Qualitative IS 302-2-201: 2008 Clause 31

Endurance Test IS 368: 1992 Clause 10 Qualitative

Finish IS 368: 1992 Clause 11 Qualitative

\~. i~ ~-- shok Kumar N. Venkateswaran Convenor Program Manager "flBt SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 11025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 16 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

IV. LAMPS, LUMINARIES AND ACCESSORIES

I. Bayonet Lamp Classification & Marking IS 1258: 2005 (RA 2003) Qualitative holder Amd. I, Clause, 6,1,8

Checking of Dimension IS 1258: 2005 (RA 2003) 0,1 mm to 250 mm Amd. I, Clause, 9

Protection Against Electric IS 1258: 2005 (RA 2003) Qualitative Shock Amd. I, Clause, 10

Terminals IS 1258: 2005 (RA 2003) Amd. I, Clause. II

Construction Requirements IS 1258: 2005 (RA 2003) 20N Amd, I, Clause. 13

Moisture Resistance. IS 1258: 2005 (RA 2003) 91 % to 95%, Insulation Resistance Amd, I, Clause. 15 IO·Cto60·C Electric Strength 0,5 kV t04 kV IMQtolTn

Mechanical Strength IS 1258: 2005 (RA 2003) 0.35 Nm, 0,5 Nm, 0.1 Nm Amd, I Clause, 16

Resistance to Heat Fire & IS 1258: 2005 (RA 2003) 6501850 ·C Tracking. Amd. I Clause. 20

Reslstanee to Excessive IS 1258: 2005 (RA 2003) Qualitative Residual Stresses And to Amd. I Rusting Clause. 21

~l~' ~ Ashok Kumar N. Venkateewaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 17 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection e!rformed

2. Luminaires Visual Examination IS 10322 (part 51Sec I): 2012 Qualitative Particular Clause. 4 Requirements Oeneral Purpose Protection Against Electric IS 10322 (part SISec I): 2012 I Vt060V Shock Clause. 12

Mechanical Strength Test IS 10322 (part 51Sec I): 2012 0.35,0,5,0.7 Nm Clause. 7

Endurance & Thermal Test IS 10322 (part SISec I): 2012 10 'C to 300 'C Clause, 13

Resistance to Dust &Moisture IS 10322 (part 51See I): 2012 Qualitative Clause. \4

Insulation Resistance IS 10322 (part 51Sec I): 2012 1 MOto 100 on Test & Electric Strength Clause, 15 At SOOV I kV to 4 kV

Resistance to Heat Fire & IS 10322 (part SISec I): 2012 I mmto ISOmm Tracking Clause, 16 (Ball Pressurc Test)

Photometric Test IS 10322 (part SISec I): 2012 1 lux to 20000 lux Clause. 17

3. Luminaires Visual Examination IS 10322 (Part 5/Sec Ill: 2012 Qualitative particular Clause. 4 requirement Retessed Protection Against Electric IS 10322 (Part SISee II): 2012 I Vto60V Shock Clause. 12

Mechanical Strength Test IS 10322 (part SISeo II): 2012 0,35,0,5,0.7 Nm Clause. 7

Endurance, Test & Thermal IS 10322 (Part SISec Ill: 2012 10 'C to 300 'C Test Clause. 13 ~ ~. ~--' AShok Kumar N. Venkateswaran Convenor Program Manager ..; HfiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I. Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 18 of 34

S.No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Luminaires Resi slance to Dust & Moisture IS 10322 (Part 5/Sec II): 2012 Qualitative particular Clause, 14 requirement Recessed Insulation Resistance Test & IS 10322 (Part 5/Sec II): 2012 I MOto 10000 Electric Strength Clause, IS AI500V ot04 kV

Resistance to Heat, Fire & IS 10322 (Part 5/Sec II): 2012 Oto 150mm Tracking Clause, 16 (Ball Pressure Test)

Photometric Test IS 10322 (Part5/Sec II): 2012 1 lux to 20000 lux Clause. 17

• 4. Luminaires Visual Examination IS 1.0322 (Part 51Sec III): 2012 Qualitative Particular Clause. 4 requirements Luminaires for Protection Against Electric IS 10322 (part 51Sec III): 2012 I Vto60V Road and street Shock Clause. 12 Lighting' Mechanical Strength Test IS 10322 (part5lSec III): 2012 0.35.0.5,0.7 Nm Clause. 7

Endurance, Test & Thermal IS 10322 (Part SISec III): 2012 10°C to 300 ·C Test Clause. 13

Resistance to Dust &Moisture IS 10322 (Part 51Sec III): 2012 Qualitative Clause. 14

Insulation Resistance IS 10322 (partS/Sec IIf): 2012 I MOto 10000 Test & Eleetric Strength Clause, 15 At500V oto 4 kV

Resistance to Heat ,Fire & IS 10322 (Part SISec III): 2012 1 mm to 150 mm Tracking Clause.l6 (Ball Pressure Test)

AshokKumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.0B.2016

Certificate Number T·40BB Valid Until 11.0B.2018

Last Amended on 10.10.2016 Page 19 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testlng I Material of Test against which tests are Limits of Detection eerformed

Luminaires Photometric Test IS 10322 (pan 51Sec Ill): 2012 I lux to 2()()()() lux Particular Clause. 17 requirements Luminaires for Wind Force Test IS 10322 (Pan 51Sec nI): 2012 Qualitative Road and street Clause. 7.3.1 Lightings

S. Luminaires Visual Examination IS 10322 (part 51Seo IV): Qualitative Particular (RA 2005), Clause, 13.2 Requirements Portable general Protection Against Electric IS 10322 (pan 51Seo IV): I Vt060V purpose Shock (RA 2005), Clause, 11.1 luminaries Mechanical Strength Test ,IS 10322 (pan 51Sec IV): 0.35,0.5,0.7 Nm (RA 2005), Clause. 13.3

Endurance, Test & Thermal IS 10322 (pan 51Sec IV): 10 ·C to 300 ·C Test (RA 2005), Clause, 13.4

Resistance to Dust &Moisture IS 10322 (pan 51Sec IV): Qualitative (RA 2005), Clause. 13.5

Insulation Resistance Test & IS 10322 (part SISco IV): I MClto 10000 Electric Strength (RA 2005), Clause. 13,6 At 500V 1 kVt04kV

Resistance to Heat, Fire & IS 10322 (part 51Sec IV): 1 mmto ISOmm Tracking (RA 2005), Clause. 13.7 (Ball Pressure Test)

Photometric Test IS 10322 (pari 51Sec IV): I lux to 20000 lux (RA 2005), Clause. 13.8

6. Luminaires Visual Examination IS 10322 (part 51Sec V): 2013 Qualitative Particular Clause. 4 requirements Flood lights ~--' H::, N. Venkateswaran Convenor Program Manager HfiBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar. Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 20 of 34

S. No. Product I Sp&cific Test Performed Test Method SpeCification Range of Testing I Material of Test against which tests are Limits of Detection I!erformed

Luminaires Protection Against Electric IS 10322 (part 5/Sec V): 2013 Indicating lamp voltage Particular Shock Ciause. 12 60 V ,75 N forx:e requirementll Flood lights Mechanical Strength Test IS 10322 (part 51Sec V): 2013 0.35,0.5,0.7 Nm Ciause.7

Endurance, Test & Thermal IS 10322 (part 51Sec V): 2013 10"C to 300'C Test Clause. 13

Resistance to Dust & Moisture IS 10322 (part 51Sec V): 2013 Qualitative Clause. 14

Insulation Resistance IS 10322 (part 5/Sec V): 2013 I Mil to 100 GO Test & Electric Strength Clause. 15 At 500V lkVt04kV

Resistance to Heat, Fire & IS 10322 (part 51Sec V): 2013 1 mm to 150mm Tracking Clause. 16 (Ball Pressure Test)

Photometric Test IS 10322 (part 51Sec V): 2013 I lux to 20000 lux Clause. 17

Wind Force Test IS 10322 (part 5/Sec V): 2013 Qualitative Clause.?3

7. Bana.t. For V isual Exam ination IS 1534 (Part I): 1977 Amd. 5 Qualitative Fluorescent Clause. 9.4 Lamps Test For Terminals for IS 1534 (Part 1): 1977 Amd. 5 0.75 mm'to 1.5 mm' External Wiring Clause. 4

Test For Screws, Current IS 1534 (Part I): 1977 Amd. 5 1 Nmto IONm Carrying Parts And Clause. 5 Connections

k""::::--- . ~-- hok Kumar N. Venkat&$waran Cdnvenor Program Manager

...- -­ HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 21 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Ballasts For Test For Creepage Distance & IS 1534 (part I): 1977 Amd. 5 1 mmto 150mm Fluorescent Clearance Clause. 7 Lamps Protection Against Accidental IS 1534 (part 1): 1977 Amd. 5 Voltage: 60 V. 75 N force Contacts With Live Parts Clause. 9.5

Test For Moisture IS 1534 (Part 1): 1977 Amd. 5 2 MQto 10 00 Resistance And Jnsulation Clause. 9.7 IVt0500V lO °C to 60°C 60 % RH to 95 % RH

Test For Limitation of Ballast IS J534 (Part I): 1977 Amd. 5 70·C to 195°C Heating Clause. 9.9

Test For Resistance to Heat IS 1534 (Part 1): 1977 Amd. 5 Oto 150mm Clause. 9.11

Test For Resistance to IS 1534 (Part 1): 1977 Amd. 5 Qualitative Corrosion Clause. 9.12

Pre Heating Conditions IS 1534 (Part 1): 1977 Amd. 5 0.9 ratio to 2.1 ratio Clause. 9.13.3

Power & Current Output IS 1534 (Part 1): 1977 Amd. 5 lWtolOOOW Clause. 9.13.4 500 V. 20 A

Overall P,F. IS 1534 (Part I): 1977 Amd, 5 0.1 unity P.f Clause. 9.13.5

Current Delivered Lamp. IS 1534 (Part I): 1977 Amd. 5 IAtolOA Clause. 9.13.6

CurrentWaveforrn IS 1534 (Part I): 1977 Amd. 5 IAtolOA Clause. 9.13.7

AshokKumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITAnON

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Utlar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 22 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Ballasts For Test For Mechanical Strength IS 1534 (Part 1): 1977 Amd. 5 Qualitative Fluorescent Clause. 9.10 Lamps Voltage Across Capacitor IS 1534 (Part 1): 1977 Amd. 5 240 V. AC, 50 Hz Clause. 9.6

8. Ballasts For Higb Visual Examination IS 6616 (Part 1): 1982 Qualitative Pressure Mereury (RA 2001) Amd. 1 Vapour Lamps Clause. 9.4

Test For Creepage Distance & IS 6616 (part 1): 1982 1 mm to 150 mm Clearance (RA 2001) Amd. 1 Clause. 6

Protection Against Accidental IS 6616 (part I): 1982 1 Vt060V Contacts With Live Parts (RA 2001) Amd. 1 Clause. 7

Test ofTenninals IS 6616 (Part I): 1982 0.04 mm'to 2.5 mm' (RA 2001) Amd. I Clause. 9.5

Moisture Resistance And IS 6616 (part 1): 1982 IMQtolOGO Insulation (RA 2001) Amd. 1 At 500V Clause. 9.6 1 Vt0500V

Test ofPower And IS 6616 (part I): 1982 Qualitative Output Current (RA 2001) Amd. I Clause. 9.7

Test of Short Circuit Current IS 6616 (Part 1): 1982 I A to 100 A (RA 200 I) Amd. 1 Clause. 9.8

N. Venkateswaran ~t:Convenor Program Manager nflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 23 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

Ballasts For High Test For Open Circuil Voltage IS 6616 (part I): 1982 IVto300V Pressure Mercury (RA 2001) Arod, I Vapour Lamps Clause, 9.9

Test For Current Wave Shape IS 6616 (part 1): 1982 Less than 1,9 Peak! (RA 200 I) Arod. I RMSof92%& 106% of Clause. 9.10 240V

Test For Protection Against IS 6616 (Part I): 1982 Qualitative Magnetic Influence (RA 2001) Arod. 1 Clause, 9.11

Limitation of Ballast Heating IS 6616 (part 1): 1982 I ·Cto 145°C (RA 2001) Arod. 1 Clause, 9.12

Test For Resistance to IS 6616 (part 1): 1982 Qualitative Corrosion And Brittleness (RA 200 1) Arod. 1 Clause. 9,]3

Test For Mechanical Strength IS 6616 (part I): 1982 Qualitative (RA 2001) Arod, 1 Clause, 9,14

V. WIRING ACCESSORIES

1. Plugs & Socket Rating IS 1293: 2005 Arod, 6 Qualitative Outlets (; A, 16 A Clause, 6

Classification IS 1293: 2005 Amd, 6 Qualitative Clause, 7

Marking IS 1293: 200S Arod, 6 Qualitative Clause. 8

AshokKumar N. Venkateswaran Convenor Program Manager tl8BL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 24 of 34

S. No. Product 1 Specific Test Performed Test Method Specification Range of Testing 1 Material of Test against which tests are limits of Detection performed

Plugs & Socket Checking of Dimensions IS 1293: 2005 Amd. 6 I mm to 150mm Outlets 6 A, 16 A Clause. 9 GO Gauge

Protection Against Electric IS 1293: 2005 Amd. 6 Qualitative Shock Clause, 10

Provision ofEarthling IS 1293: 2005 Amd. 6 Qualitative Clause, II

Terminals IS 1293: 2005 Amd, 6 Qualitative Clause, 12

Constructional Requirements IS 1293: 2005 Amd, 6 Qualitative ofFixed Socket Out Let Clause. 13

Constructional Requirements IS 1293: 2005 Amd. 6 Qualitative ofPortable Socket OUI Let Clause. 14

Interlocked Socket Outlet IS 1293: 2005 Amd. 6 Qualitative Clause. 15

Resistance to Aging IS 1293: 2005 Amd. 6 Upto 200'C Clause, 16.1

Resistance to IS 1293: 2005 Amd.6 Qualitative Harmful Ingress ofWater Clause, 16.2

Resistance to Humidity IS 1293: 2005 Amd, 6 4 %RH to 95 % RH Clause, 163 1°C to 60"C

Insulation Resistance & IS 1293: 2005 Amd. 6 1 MOto lOGO Electric Strength Clause. 17 At 500V 0.5 kV t04 kV

Operation of Earthing Contact IS 1293: 2005 Amd, 6 Qualitative Clause. 18

s ok Kumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Gha:z:labad, Uttar Pradesh

Accreditation Standard ISOilEe 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 25 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test Bgainst whiCh tests are Limits of Detection performed

Plugs & Socket Temperature Rise IS 1293: 2005 Amd. 6 Ambient to 200 'C Outlets 6 A, 16 A Clause. 19

Making &Braking Capacity IS 1293: 2005 Amd. 6 Upto 20 A, 300 V Clause. 20

Normal Operation IS 1293: 2005 Amd, 6 1 At040A Clause. 21

Force Necessary to IS 1293: 2005 Amd.6 0.5 N to JON Withdraw The Plug Clause. 22

Flexible Cable & their IS 1293: 2005 Amd. 6 Qualitative Connection Clause. 23

Mechanical Strength IS 1293: 2005 Amd.6 0101500 mm Clause. 24

Resistance to Heat IS 1293: 2005 Amd. 6 I °C to 3OO'C Clause. 25

Screws ,Current Carrying IS 1293: 2005 Amd. 6 Qualitative Parts Connection Clause. 26

Creepage Distance, Clearance IS 1293: 2005 Amd. 6 1 mmto250mm & Distance Through Sealing Clausc.27 Compound

Resistance of Insulation IS 1293: 2005 Amd, 6 650 'C & 850'C Material to Abnormal Heat, Clause, 28 Glow wire Test apparatus Fire & Tracking

2. Domestic Checking ofDimension. IS 3854: 1997 Amd. 6 1 mmto250mm Switches Clause, 9 Upto32 A i~ ~- shokKumar N. Venkateswaran Convenor Program Manager HABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 26 of 34

S.No. Product I Specific Test Pertormed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Domestic Protection Against Electric IS 3854: 1997 Amd. 6 Qualitative Switch.. Shock Clause. 10 Upto 32 A Terminals IS 3854: 1997 Amd. 6 ION Clause. 12

Constructional Requirements IS 3854: 1997 Amd. 6 120N Clause. 13

Mechanism IS 3854: 1997 Amd. 6 Qualitative Clause. 14

Resistance to Ageing. IS 3854: 1997 Amd. 6 Ambient to 150 'c Clause. 15.1

Resistance to Harmful Ingress IS 3854: 1997 Amd. 6 Qualitative of Water. Clause. 15.2

Resistance to Humidity IS 3854: 1997 Amd. 6 95% Clause. 15.3

Insulation Resistance & IS 3854: 1997 Amd. 6 IMQtolTQ Electric Strength Clause. 16 At 500V 0.5 kV to 4 kV

Temperature Rise IS 3854: 1997 Amd. 6 10 'C to 100 'C Clause. 17

Making & Breaking Capacity IS 3854: 1997 Amd. 6 20 A at 275 V Clause. 18

Normal Operation IS 3854: 1997 Amd. 6 20 A, 250 V Clause. 19

Mechanical Strength IS 3854: 1997 Amd. 6 1.9Nt02.0N Clause. 20

~W' ~..-' shok Kumar N. Venkateswaran Convenor Program Manager SCOPE OF"fiSL ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 27 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection perfofllled

Domestic Resistance 10 Heat IS 3854: 1997 Amd. 6 I 'C to 300 'C Switches Clause. 21 Upto 32 A Serews, Current Carrying IS 3854: 1997 Amd. 6 Qualitative Parts & Connections. Clause. 22

Creepage Distance, Clearances IS 3854: 1997 Amd, 6 1 mmto 150mm & Distance Through Sealing Clause, 23 Compound,

Normal Operation For IS 3854: 1997 Amd, 6 20 A, 250 V Fluorescent Lamp Circuit. Clause, 19.2 0.3 p.r. (lag)

Resistance to Abnormal Heal IS 3854: 1997 Amd, 6 Glow Wire Test Apparatus & Fire Clause. 24.1 (850 'C & 650 'c)

3. Ceiling Rose. Markings IS 371: 1999 (RA 2005) Qualitative Amd, 4 Clause, 9

Checking of Dimensions IS 371; 1999 (RA 2005) 0,1 rom to 150 mm Amd.4 Clause, 10

Accessibility of Live Parts IS 371: 1999 (RA 2005) Qualitative Amd.4 Clause, 11

Terminals IS 371: 1999 (RA 2005) Immt050mm Amd.4 Clause, 13

Construction IS 371: 1999 (RA 2005) Qualitative Amd.4 Clause, 14

shok Kumar N. Venkateswaran Convenor Program Manager nflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.). Kamla Nehru Nagar. Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005 Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 28 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Ceiling Roses Resistance to Humidity IS 371; 1999 (RA 2005) 95% Insulation Resistance Amd.4 1 Mnto 10Gn Electric Strength Clause. 15 I kVt04kV

Temperature Rise IS 371: 1999(RA 2005) I 'CtoIOO'C Amd.4 Clause. 16

Mechanical Strength. IS 371; 1999 (RA 2005) Qualitative Amd.4 Clause. 17

Resistance to Heat IS 371; 1999 (RA 2005) Ambient to 200 'c Amd.4 Clause. 18

Resistance to Abnormal Heat IS 371: 1999 (RA 2005) Glow Wire Test Apparatus & Fire. Amd.4 (850 'C & 650 'C) Clause. 19

Screws. Current Carrying IS 371; 1999 (RA 2005) Qualitative Parts & Connections. Amd.4 Clause. 20

Creepage Distance, Clearances IS 371; 1999 (RA 2005) 1 mmto 15Qmm & Distance Through Sealing Amd.4 Compound. Clause. 21

Resistance to Excessive IS 371: 1999 (RA 2005) Qualitative Residual Stresses And to Amd.4 Rusting Clause. 22

~.

Ashok Kumar N. Venkateswaran Convenor Program Manager HABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 29 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

VI. CABLES AND ACCESSORIES

1. Eleotrlcal Cable Annealing Test (Copper) IS 10810 (part I): 1984 0.5 mm2 to 10 mm' (PVC Insulated (RA 2001) cable and Sheated LT Cable) Tensile Test (Aluminum) IS 10810 (Part 2): 1984 0.5 mm2 to 10 mm' XLPECable (RA 2001)

Wrapping Test (Aluminum) IS 10810 (Part 3): 1984 Qualitative (RA 2001)

Conductor Resistance Test IS 10810 (Part 5): 1984 1 )in to 100 n (RA 2001)

Resistivity Test of Armour IS 10810 (Part 42): 19~4 I fln to loon Wire and Strip (RA 2001)

Tensile Test For Armour IS 10810 (part 37): 1984 I mm't06 mm' (RA 2001)

Elongation Test For Armour IS 10810 (Part 37): 1984 0lo500N (RA 2001) oto 150 mm

Winding Test On Galvanized IS 10810 (Part 39): 1984 Qualitative Steel Strip On Armouring (RA 2001)

Torsion Test On Armour Wire IS 10810 (Part 38): 1984 Qualitative (RA 2001)

Thickness ofInsulation And IS 10810 (Part 6): 1984 0.001 mm to 50 mm Sheath (RA 2001)

Tensile Strength And IS 10810 (Part 7): 1984 oto SOON Percentage Elongation of (RA 2001) 010150mm Insulation Sheath

Aging in Air Oven IS 10810 (Part 11): 1984 27 ·C to 200°C (RA 2001)

N. Venkatuwaran Program Manager HASL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 30 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Meterlal of Test against which testa are Limlta of Detection performed

Electrical cable Hot Deformation Test IS 10810 (Part 15): 1984 0.01 mm to 150 mm (PVC lruiulated (RA 2001) cable and sheated LT Cable) Loss of Mass In Air Oven IS 10810 (Part 10): 1984 0.1 mg to 200 g XLPEcable (RA 2001)

Heat Shock Test IS 10810 (part 10): 1984 Qualitative (RA 2001)

Insulation Resistance Test IS 10810 (Part 43): 1984 1MQ to I Tn (RA 2001) At 500 V 1 Mohm to 1 Tohm

High Voltage A .C. Test IS 10810 (Part 45): 1984 oto 6 kV (Water Immersion Test) (RA 2001)

High Voltage D.C. Test IS 10810 (Part 45): 1984 Oto 2 kV (Water Immersion Test) (RA 2001)

Flammability Test IS 10810 (part 53): 1984 1 mm to 150mm (RA 2001)

Overall Diameter IS 10810 (Part 6): 1984 1 mm to 150 mm (RA 2001)

Shrinkage Test IS 10810 (Part 12): 1984 1 mm to 300 mm (RA 2001)

Hot Set Test IS 10810 (part 30): 1984 I mm to 150mm (RA 2001)

Water Absorption IS 10810 (part 33): 1984 0.1 mg to 200 g (Gravimetric) (RA 2001)

Thermal Stability Test IS 10810 (Part 60): 1984 Qualitative (RA 2001)

N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 31 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

VD. SWITCHGEAR EQUIPMENT

1. Circuit Breakers Clearances & Creepage IEC 60898, 2002 Immtol50mm For Over Current Distances (IntemallExternal) Clause, 8,1.3 & I mm to 300 mm Protection for Parts (0,02 mm) House Hold & Similar Inedibility ofMarking IEC 60898, 2002 Qualitative Installation Clause, 9.3

Reliability ofScrews, Current IEC 60898, 2002 Torque test Carrying Parts & Connections Clause, 9.4 0,1 Nm to 2,0 Nm

Reliability of Screws Type IEC 60898: 2002 Torque test Terminal For External Clause, 9.4 OJ Nm to 10,0 Nm Conductor

Protection against Electric lEC 60898: 2002 Indicating lamp voltage Shock Clause, 9,6 60.75 N force

Resistance to Heat lEC 60898: 2002 25 ·C to 150·C Clause, 9.14

Res; stance to Abnormal lEC 60898: 2002 650(±)10 ·C, 960(±)15·C Heat and to Fire Clause. 9.15

Resistance to Rusting lEC 60898: 2002 Qualitative Clause, 9,15

Dielectric Properties IEC 60898: 2002 oto 5 kV ao Clause, 9.7

Resistance to Humidity lEC 60898: 2002 RH:60%t095% Clause. 9,7,1

N. Venkateswaran Convenor Program Manager

----""--­ rtflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 32 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Clreuit breakers Insulation Resistance ofthe lEC 60898: 2002 1 MOto 10m for over current Main Circuit Clause. 9.7.2 protection fot bouse hold & Dielectric Strength of Main lEC 60898: 2002 Ot05 kV A.C similar Circuit Clause. 9.7.3 installation Dielectric Strength of the lEC 60898: 2002 Ot05 kV A.C Auxiliary and Control Circuit Clause. 9.7.4

Verifications of Impulse lEC 60898: 2002 1.5 kV to 10 kV Withstand Voltage across the Clause. 9.7.6.1 Open Contacts

Verifications of Impulse lEC 608'l8: 2002 1.5 kV to 10 kV Withstand Voltage for the Clause. 9.7.6.2 Parts in the Close Contacts

Verifications of Leakage lEC 60898: 2002 Oto 10 mA, Currents Across Open Clause. 9.7.6.3 Contacts

Temperature Rise lEC 60898: 2002 1 'C to 300 'C Clause. 9.8

28 Day Test lEC 60898: 2002 5 A to 125 A Clause. 9.9

Mechanical & Electrical IEC 60898: 2002 Otol25A Endurance Clause. 9.11

Tripping Characteristics lEC 60898: 2002 Ot09.995 Clause. 9.10

Resistance 10 Mechanical IEC 60898: 2002 150g(±)lg Shock & Impact Clause. 9.13

\~. I ~-- AshokKumar N. Venkateswaran Convenor Program Manager

...... __.. "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T·4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 33 of 34

S. No. Product I Specific Test Performed Test Method SpeCification Range of Testing I Material of Test against which tests ara Limits of Detection performed

VIII. ELECTRICAL MATERIALS -SOLID INSULATING MATERIALS

1. Insulating Mal. Insulalion Resistance with IS 15652: 2006 & IS 2584 I TOto IOTa For Electrical Water Clause. 3.1 500 V DC to 5000 V DC Purpose. I roto 10 TO 500 V to 5000 V DC

Leakage Current IS 15652: 2006 & oto 1000 ItA,300 V IS 2584: J963 (RA 2006) Clause. 3.2

AC Dielectric Strength IS J5652: 2006 & 500 V to 125 kV, IS 2584: 1963 (RA 2006) 50Hz Clause. 3.3

AC Proof Voltage IS 15652: 2006 & 500 V to 125 kV IS 2584: 1963 (RA 2006) 50 rnA, Clause. 3.4 50kV, 200 rnA

Low Temperature Resistance IS 15652: 2006 & (.) 15'C to 45 OC Test IS 2584: 1963 (RA 2006) 350 mm x 250 mm Clause. 8,4 lOON weight

IX. ENVIRONMENTAL TEST FACILITY

I. Electronics and Cold Test for Non Heating IS 9000 (Part 21Sec II): 1977 Upto(-)40'C Electrical Items Dissipating Items with Sudden IS 9000 (Part 2/S.. Ill): 1977 Range ofdetection (±)1 ' of Temperature IS 9000 (Part 21S.. IV): 1977 3 'ClMin

Damp ( Cyclic test ) IS 9000 (Part V/Sec 1 & Sec 2) 25 'C to 80'C Section 1: 16+8 Hrs Cycle Range of detection (±)1 'C Section 2: 12+12 Hrs Cycle 3% lMin RHUpto 95% ~\~. ~AShOk Kumar N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electrical Testing Issue Date 12.08.2016

Certificate Number T-4088 Valid Until 11.08.2018

Last Amended on 10.10.2016 Page 34 of 34

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Electronles and Dry Heat Test IS 9000 (Part 3/Sec I to V): 1977 0 ·C to 300 ·C Electritalltems (RA 2007)

2. Degrees of Degree of protection against IS 12063 -1987, Reaff2oo4 IP IX: 0 to 50 mm Proteetion (lP) ingress of dust & water IEe 60947-1 :2004 IP2X: 0 to 12 mm provided by IEC 60529:2004 IP3X: 0 to 2.5 mm eotlosures of IP4X: 0 to 1.0 mm Electrical and IP5X: 0 to 0.1 ~m Electronies IP6X: 0 to 0.1 ~m Equipment. IPXl: 0 to 0.4 mm lPX2: 0 to 0.4 mm IPX3: 0 to 05 mm IPX4: 0 to 0.4 mm lPK5: 0 to 6.3 mm IPX6: 0 to 12.5 mm lPX7: 0 to 1 meter lPXS: 0 to 1 meter

-x-X-x-x-x-x-x-X-x-x-x-x-x-x-

Ashok Kumar N. Venkate5waran Convenor Program Manager "ABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T·3901 Valid Until 13.10.2017

Last Amended on Page 10f10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

I. ENVIRONMENTAL TEST FACILITY

I. Electronic Office Dry Heat Test IS 9000 (Part 3/See V): 1977 oto 300 GC Eqpt. (RA 2007)

Cold Test IS 9000 (Part 21See IV): 1977 oto (-)40 GC (RA 2007)

Damp Heat Test IS 9000 (Part 51S.. I.to V): 1981 Oto 100GC (RA 2007) Ambient to 98% RII

II. IT EQUIPMENT

l. Information Input Current [S 13252 (Part I): 2010 AC/DC: 1000 V Technology Clause 1.6,2 ImAto20A Equipment.Sarety Protection In Operator Access IS i'n52 (Part I): 2010 Qualitative Area Clause 2.Ll

Durability IS 13252 (Part t): 20 I 0 Qualitative Clause 1,7,11

Access To EL V Wiring IS 13252 (Part I): 2010 Qualitative (Eleetric Strength Test) Clause 2,1.1,3

Access To Hazardous Voltage IS 13252 (Part I): 20 10 oto 4 kV Clause 2. I,1,4

Manual Controls IS 13252 (Part l): 2010 oto 4 kV (Electric Strength Test) Clause2.I.L6

Energy Hazard IS 13252 (Part I): 2010 Qualitative (De Mains Supply) Clause 2.1.1.8

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T-3901 Valid Until 13.10.2017

Last Amended on Page 2 of 10

S. No. Product! Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Jnformation Protection in Service Area IS 13252 (Part I): 2010 Same as clause 2, 1,1.7 Technology Clause 2.1.2 ~;quipmcnt·S.fc(y Protection in Restricted Access IS 13252 (Part 1):2010 Same as cl.use 2.1.1.7 Location Clause 2,1.3

Voltage in Normal Condition IS 13252 (Part I): 2010 Acmc: 1000 V Clause 2.2.2

Voltage Under Fault Condition IS 13252 (Part I): 20 I 0 Uplo 100 V Clause 2.2.3

Condition to SELV Circuit To IS 13252 (Part I): 20 I 0 UplO 100 V Other Circuit Clause 2.2.4

Protection by basic Insulation IS 13252 (Part I): 2010 0(04 kV Clause 2.3 .2.2

Protection by earthing . IS 13252 (Part 1): 20 I 0 IM>ilo I 'IIi Clause 2,3.2.3

Protection by Construction IS 13252 (Part I): 20 IO IMn to I T!) Clause 2.3.2.4

Separation from Hazardous IS 13252 (Part 1): 2010 Qualitative Voltage Clause 2.3.3

Limits ofTN V Circuit IS 13252 (Part I): 2010 5 OlA (0 20 A Clause 2.3.1

Connection of'INV Circuit to IS 13252 (Part I): 20 I 0 5 mA to 20 A Other Circuit Clause 2,1.1.9 & ACfI)C: 1000 V Clause 4.5.1 Current: 10 A (Jointl rigid 30 N)

Pooia Singh N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T·3901 Valid Until 13.10.2017

Last Amended on Page 3 of 10

S. No. Product! Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Information Test for Operating Voltages IS 13252 (Part I): 2010 Acmc: 1000 V Technology Generated Externally Clause 2.3.5 Current: lOA .:quipmcnt-S.fely

Limited Current Circuits1 IS 13'252 (Part I): 2010 ACIDC-I aoov Limit Values Clause 2.4.2

Limited Power Source IS 13252 (Part I): 2010 AcmC-lOOOV Clause 2.5

Provision for Earthing and IS 13252 (Part I): 2010 oto 150 mm & Bonding Clause 2.6 oto 300 mm LCO.02 mm Ace: 0.01 mm Ot025 mm LC:O.OOI mm

Short Cireuit Back Up IS 13252 (Pan I); 2010 Qualitative Protection C,lause 2.7.3

Number & Loe.tion of IS 13252 (Part I): 2010 Qualitative Protective Device Clause 2.7.4

Protection Requirements IS 13252 (Part I): 2010 Qualitative Clause 2.8.2

Inadvertent Reactivations IS 13252 (Part I): 2010 Qualitative Clause 2.8.3

Fail Safe Operation IS 13252 (Pan I): 20 I 0 Qualitative Clause 2.8.4

Over Riding [S 13252 (Panl): 2010 Qualitative Clause 2.8.6

Pooja Singh N. Venkateswaran Convenor Program Manager nflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T·3901 Valid Until 13.10.2017

Last Amended on Page 4 of 10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Information f'lumidity Conditioning IS 13252 (Part I): 2010 (-)40'Cto(l) 180'C, Technology Clause 2.9.2 Ambient to 98 % 1<11 Equipment-Safety I.C: 0.1 'ClRlI & Ace (.1)2 'C l.2%IUI Range: 0 to 4 kV

Crcepage Distaneel Clear.neel IS 13252 (Part I): 20 I 0 oto 150mm & Distance through Insulation Clause 2.10 ato 300 mm (Determination of LCO.02mm requirements: Working Ace: 0.01 mm Voltage Measurements) Range: 0 to 25 mm

RMS Working Voltage IS 13252 (Part I): 2010 AcmC-1000 V Clause 2.10.2.2

Determination Of Peak IS 13252 (Part I): 20 I 0 ACIDC-IOOO V Working Voltage Clause 2.10.2.3

Clearances IS 13252 (Part I): 2010 oto 150 mm& Clause 2.10.3.1, 2.10.3.2,2.10.3.3, oto 300 mm 2,10.3.4,2.10.3.6,2.10.3.7, LCO.02 mm 2.10,3.8 Ace: 0.01 mm Range: 0 to 25 mm I.C: 0,001 mm

Creepage distances IS 13252 (Part I): 20 I 0 oto 150mm & Clause 2.10.4 a to 300 mm I.C O.02mm Aec: 0.0 I mm

Solid Insulation IS 13252 (Part I): 20 I 0 Oto 150 mm & Clauso2.IO.5.1 o ioJOOmm I.e 0.02 mm Ace: 0.0 I min

Pooja Singh N. Venkateswaran Convenor Program Manager nflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.). Kamla Nehru Nagar. Ghaziabad. Uttar Pradesh

Accreditation Standard ISOIIEe 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T·3901 Valid Until 13.10.2017

Last Amended on Page 5 of 10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Information Distance Through Insulation IS 13252 (Part I): 20 I 0 Range: 0 (04 kV Technology Clause 2.10.5.2 ~:quipmcnt-S.r.ty Insulating Compound at Solid .'IS 13252'(Part 1): 20 I 0 Range: 0 to 4 kV Insulation Clause 2.10.5.3

Uncoated Printed Board IS '13252 (Part I): 20 I 0 Oto 150mm& Clause 2.10.6.1 0(0300 mm I.C 0.02 mm Ace: 0.01 mm

Abrasion Resistance Test IS 13252 (Part I): 2010 Qualitative Clause 2.10.8.4

Current Rating & Over Current IS 13252 (Part I): 2010 300°C Protection Clause 3.1.1

Insulation OfCondue tors IS 13252 (Part I): 2010 Range: 0 (0 4 kV Clause 3.1.4

Wiring Connection and supply IS 13252 (Part I): 2010 10 N force ION Steady Force Test Clause 3.1.5, 3.1.9 & 4.2.2

Serew For Electrical Contact IS 13252 (Part I): 2010 Joint! Rigid 30 N Pressure Clause 3,1.6

Insulating Materials In IS 13257 (Part I): 20 I 0 Qualitative Electrical Connections Clause 3.1.7

Multiple Supply Connections IS 13252 (Part I): 2010 Joinl! Rigid 30 N Clause 3.2.2

Permanently Connccted Eqp! IS 13252 (Part I): 20 I 0 0(0 150mm & Clause 3,2.3 010300 mm LC 0.02 mm Ace: 0,01 mm

Pooja Singh N. Yen kateswaran Convenor Program Ma nager nABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T-3901 Valid Until 13.10.2017

Last Amended on Page 6 of 10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Information Appliance Inlet IS 13252 (Part I): 20 I 0 Joint/ Rigid 30 N Technology Clause 3.2.4 Equipment-Sarety AC Power Supply Cords IS 13252 (Part I): 2010 60, 90, 180, 270 'C Clause 3,2.5.1 (olo)l 'C

Cord Anchorage And Strain IS 13252 (Part I): 2010 0.25"1 to SON Relief Clausc 3.2.6

Protection Against MechanICal IS 13252 (Part I): 20 I 0 oto 150mm& Damage Clause 3.2.7 oto 300 mm LCO.02 mm Acc: 0.01 mm

Cord Guards IS 13252 (Part I); 20 I 0 0.25 N to 50 N Clause 3.2.8

Supply Wiring Spaces IS 13252 (Par! I): 2010 010 150mm& . Clause 3.2.9 Ot0300 mm LCO.02 mm Ace: 0.01 mm

Wiring Terminals for . IS 13252 (Part I): 2010 oto 150 mm& Connection of Ex:ternal Clause 3.3 oto 300 mm Conductors LCO.02mm Acc: 0.0 I mm I 'C to 300'C

Impact Test IS 13252 (Part I): 20 I a 50 mm weight Clause 4.2.5 500 g with string

Drop Test IS 13252 (Part 1): 2010 50 mm weight Clause 4.2.6 500 l! with string

Pooja Singh N, Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T·3901 Valid Until 13.10.2017

Last Amended on Page 7 of 10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

Information Stress Relief IS 13252 (P1!rt I): 20 10 (.) 40'C to (1)180 'C. Technology Clause 4.2.7 Ambien! to 98 % RII ~;quipmcnt-S. rely I.C(·) 0.1 'ClRIl& Ace (I ) 2 'C, (I.) 2 % RII

Protection against lIazardous IS 13252 (Part I): 2010 loinll Rigid 30 N Moving Parts Clause 4.4

Thermal Requirements IS 13252 (Part I): 2010 (-) 40'C to (Il 180 'C, Clause 4.5.2 & 4.5.3 Ambient to 98 % IHI LC (-l 0.1 'CI RH & Ace (+) 2 'C, (I) 2 % Itll

Resistance to Abnormal lIeat IS 13252 (Part I): 20 I 0 (-) 40 'c to (I) 180 'C, Clause 4.5.5 Ambient to 98 % RII I.C (.) 0.1 °Cl RIl & Ace (01.) 2 'C, (I) 2% RII

Evaluation of Larger Openings IS 13252 (Part I): 20 I 0 Qualitative Clause 4.6.4.2

Touch Curren! and Protective IS 13252 (Part I): 20 I0 I ~A to 999 ~A Conductor Current Clause 5.1

Electric Strength IS 13252 (Part 1): 20 10 0.5 kV to 5 kV AC Clause 5.2 0.5 kV to 2 kV DC

Protection Against Overload IS 13252 (Part I): 2010 Qualitative tesl And Abnormal Operation Clause 5.3.1

Impulse Test IS 13252 (Part I): 2010 0.5 kVp to 6 kVp CI.use 7.4.3 1.21 SO ~s

Marking & Instruction IS 616 (Part I): 2010 Qualitative Requirements Clause 5

Pool a Singh N. Venkateswaran Convenor Program Manager "fiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

. Accreditation Standard ISOIIEC 17025: 2005

Discipline Electronics Testing Issue Date· 22.04.2016

Certificate Number T-3901 Valid Until 13.10.2017

Last Amended on Page 8 of 10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Information Heating undcr Normal IS 616 (Part I): 2010 Ambient to 250·C Technology Operating Condition Clause 7 LC I·C .:quipmcnt-Safcty Protection against Electric IS 616 (Part I): 2010 0.5 kY to 5 kY AC Shock Clause 8.2

Insulation ofHazardous Live. IS 616 (Part I): 2010 (-)40·CtO(i) 180'C, Parts Clause 8.3 Ambient to 98 % RII LCH 0.1 OCt RII & Ace ("..) 2 ·e, (.1') 2 % lUi

Electrical Shock U.,.ard under IS 616 (Part I): 2010 Jeinlf Rigid 30 N Normal Operating Condition Clause 9.1.1 to 9.1.2

Moisture Resistance IS 616 (Part I): 2010 (-) 40·C to (+)180 "C, Clause 10.2 to 10.2.2 Ambient to 98 % RH Le (-) 0.1 'C1 RII & Ace (n 2 ·C, (.L) 2 % RII

Insulation Resistance And IS 616 (Part I): 2010 I kY to 50 kY Dielectric Strength Clause 10.3

Fault Condition IS 616 (Part I): 2010 AC: 1 ~A to 999 ~A Electric Shock Hazard Clause 11.1

Fault Condition Heating IS 616 (Part 1): 2010 Ambient 10 250 ·C Clause 11.2 LC I·C

Impact Tcst IS 616 (part I): 20 I0 50 mm weight Clause 12,1.3 500 g with string

Drop Test IS 616 (Part I): 20 I 0 50 mm weight Clause 12.1.4 500 g with string

Pooja Singh N. Venkateswaran Convenor Program Manager "ABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I. Kamla Nehru Nagar. Ghaziabad, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T-3901 Valid Until 13.10.2017

Last Amended on Page 9 of 10

S. No. Product J Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Information Stress rclicftcst [S 616 (Part I): 2010 (-)40'CIO(I) 180·C, Technology Clause 12.1.5 Ambient to 98 % RII ~;quipment-Safely LC(-)O.1 '(,)RII& Ace (,e) 2 'C. (,q 2 % RII

Drawers IS 616 (Part 1): 2010 Qualitative Cl.use 12.4

Clearance and Creepage IS 616 (Part I): 2010 Joint! Rigid 30 N Distance Clause 13.1, 13.2, 13.3.1,13.3.2, (-) 40 'C to (I) 180 'C, 13.3.3,13.4 and 13.5 Ambient to 98 % J( II LC (-) 0.1 'Ct RII & Ace (k) 2 'C, (I) 2 % RI I

Provision for Protective IS616 (Part I): 2010 1 Mnto I Tn Earthing Clause 15.2

External Flexible Cords IS 616 (Part I): 2010 0.5 N 10250 N Clause 16

Elcctricat connection And IS 616 (Part I): 2010 0.5 Nt0250N Mechanical Fixing Clause 17.1 to 17.6

Ageing Process IS616(Part 1):2010 (-) 40 'C 10(+) 180 'C. Clause 18.2.1 Ambient 10 98 % !tIl LC (.) 0.1 'Ct RII & Aee (,L) 2 "C, (-10) 2 % RII

2. Degree of Degrcc of protection against IS 12063 IPIX-0-50 mm I'rotection (IP) ingress ofdust & W"~tcr IS 13947 II'2X-O-12 mm provided by IEC 60529: 2004 1I'3X-O-2.5 mm enclosures (Low IP4X-O-1.0 mm Voltage Switch IP5X·0·O.1 I,m Gear And Control IP6X-O-0.1 !lm Gear) IPX 1-0-0.4 mm

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad. Uttar Pradesh

Accreditation Standard ISOII EC 17025: 2005

Discipline Electronics Testing Issue Date 22.04.2016

Certificate Number T-3901 Valid Until 13.10.2017

Last Amended on Page 10 of 10

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Degree of Degree of protection against IS 12063 II'X2·0-0A mm Protection (IP) ingress ofdust & water IS 13947 II'X3-0-0,5 mm provided by me 60529: 2004 IPX4-0-0A mm cnclosu res (Low II'X5-0·6,3 mm Voltage Switch II'X6-0-12,5 mm Ge.. And Control ll'X7-0-1 m Gear) [j'X8-0-1 m

Insulation Resistance I to 5000 MO al5001 1000V

High Voltage Test 0.05 kV 106 kV (AC) 0.05 kV to 10 kV (DC) -x-x-x-x-x-x-x-x-x-x-x-x-x-x-

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 1 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Materia I of Test against which tests are Limits of Detection performed I. BUILDINGS MATERIALS

1. Cement Setting Time IS 4031 (Part 5): 88 (RA 2009) 10 min to 700 min 33 Grade OPe Amd,2 43 Grade OPe Standard Consistency 43S Grade OPC [S 4031 (Part 4): 88 (RA 2009) 10%1050% 53 GradeOPC Amd, 2 53 S Grade OPC Fineness by IS 4031 (Part 2): 99 (RA 2008) 200 m'/kg to 500 m'lkg Portland Slag Specific Surface Amd.l Cement Soundness By Portland IS 4031 (Part 3): 88 (RA 2009) 0,5 mm to 15 mm Le - Chatelier Method Pozzolana Amd.2 Cement Fly Soundness by Autoclave IS 4031 (Part 3): 88 (RA 2009) (-)0.001 %102 % Ash,Calcined Amd.2 Clay Based Portland Whit. Compressive Strength IS 4031 (Part 6): 88 (RA 2009) 0.5 N!mm'to 80 N!mm' Cement Amd,4

Density IS 4031 (Part [I): 88 (RA 2009) 2.0 gfec to 3,5 gfee

Drying Shrinkage IS 4031 (Part 10): 88 (RA2009) (-)0.001 %t02% Amd.1

2. Fly Ash! Fineness -Specific Surface by IS 1727: 1967 (RA 2008) 200 m'lkg to 800 m'/kg Pulverized Fuel Blaine's Permeability Method Amd.2 Ash ror use as Pozzolana in Lime Reactivity- Average IS 1727: 1967 (RA 2008) 0.5 N!mm'to 15 Nlmm' Cement, Cement Compressive Strength Amd,2 Mortar aDd Concrete for use Compressive Strength 28 Days IS 1727: 1967 (RA 2008) 0.5 N/mm'to 80 Nlmm' as Admixture in Amd.2 50%to 120% Cement Mortar Partieles retained on 45 Mieron and Concrete IS 1727: 1967 (RA 2008) 0.1 %to 100 % IS Sieve (Wet Sieving) Amd.2

Soundness by Autoclave Test IS 1727: 1967 (RA 2008) (-)0,001 %t02% Amd,2

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 2 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection eerformed

3. Cement Concrete Water Absorption IS 1237: 2012 1 %1030% Flooring Tile. IS 13801: 2013 Chequered Cement Concrete Wet Transverse Strength [S 1237: 2012 0.1 N/mm'to 15 Nlmm' Tiles [513801: 2013

Resistance to Wear IS 1237: 2012 0.1 mmto30mm IS 13801: 2013

Dimensions IS 1237: 2012 1 mm to 300 mm IS 13801: 2013

4. Precast Concrete Water Absorption IS 15658: 2006 {RA 2011) I %to 15% Blocks For PRving Compressive Strength IS 15658: 2006 (RA 20 II) I N/mm'to 80 N/mm' Upto20oo KN

Resistance to Wear IS 15658: 2006 (RA 2011) 10 mm'to 50000 mm' pcr 5000 em'

Dimensions IS 15658: 2006 I mm to 500mm

5. Aggregates Size and Grading IS 2386 (Part 1): 63 (RA 2011) 75 ~ to 80 mm CORrse and Fine Amd.4

Deleterious Materials & Organic [S 2386 (Part 2): 63 (RA 2011) Ot025% Impurities Amd.l

Soundness of Aggregates IS 2386 (Part 5): 63 (RA 20 II) 0.1 %to 30 %

Crushing Value IS 2386 (Part 4): 63 (RA 20 II) l%t050% Amd.3

Impact Value IS 2386 (Part 4): 63 (RA 20 II) 1%1050% Amd.3

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.). Kamla Nehru Nagar. Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 3 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Aggregate. Abrasion Value IS 2386 (Part 4): 63 (RA 2011) I %t070% Coars. and Fine ( by Los Angeles) Amd.3

Water Absorption IS 2386 (Part 3): 63 (RA 20 II) OJ %t030 %

Bulking of Fine Aggregates IS 2386 (Part 3): 63 (RA 2011) oto 50%

Flakiness Index and Elongation IS 2386 (Part I): 63 (RA 2011) oto 80 % Index Amd. 4

6. Common Burnt Water Absorption IS 3495 (Part 2): 92 (RA 20 II) 1 %t030 % Clay Building Bricks Compressive Strength IS 3495 (Part \): 92 (RA 2011) 0.5 NI mm'to 80 NI mm' Pulveriud Fuel Ash -Lime Efflorescence IS 3495 (Part 3): 92 (RA 2011) Qualitative Bricks (Visual)

Dimensions IS 1077: 92 (RA 201 I) Length Amd.1 I mm to 5000 mm Width IS 12894: 02 (RA 2012) I mm to 3000 mm Height Amd. I I mm to 2000 mm

7. Pressed Ceramic Water Absorption IS 13630 (Part 2): 2006 0.1 % to 30 % Tiles (RA2011)

Modulus of Rupture! IS 13630 (Part 6): 2006 I N/mm2 to 60 N/mm' Breaking Strength (RA 2011)

Determination ofChemica! IS 13630 (Part 7): 2006 Qualitative resistance (RA 2011) (Visual Examination) 'IS 13630 (Part 8): 2006 (RA 2011)

Crazing Resistance IS t 3630 (Part 9): 2006 Qualitative (RA2011) (Visual Examination)

Pooja Singh N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad. Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 4 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

8. Cement Concrete Compressive IS 516: 1959(RA 2008) 0.5 Nlmm' to 80 N/mrn' Cubes, Cores Strength . Amd.2

9. Integral Water Permeability to Water IS 2645: 2003 (RA 2009) I rnl to 1000 ml. Proofing Compounds Compressive IS 516: 59 (RA 2008) 0.5 N/mm' to 100 N/mm2 Strength Amd.2

Setting Time IS 4031 (Part 5): 88 (RA 2009) 10 min to 700 min Amd.2

10. Timber PRnelled Dimensional changes caused by IS 1659: 2004 (RA 2009) O. I mm to 50 mm (t) Materials Humidity Amd.2 0.1 mm to 200 mm (I) Block Boards, Plain Particle Resistanee to IS 1659: 2004 (RA 2009) Qualitative Boards, Water Amd.2 Pre -Laminated Particle Boards, Water Resistance Test IS 1328: 96 (RA 2009) Amd. 6 Qualitative Medium Density Fibre Boards, Mois,"re Content IS 1734 (Part I): 83 (RA 2008) I %t035% Pre-Laminated IS 2380 (Part 3): 77 (RA 2008) Medium Amd.4 Density Fibre IS 1708 (Part I): 86 (RA20tO) Boards~ IS 287: 93 (RA 2008) Ply Wood, Timber Spot Test IS 1659: 2004 (RA 2009) Qualitative Wooden Flush Amd.2 Deors 2 2 Marine Ply Modulus of Rupture and IS 2380 (Part 4): 77 (RA 2008) 5 N/mm to 150 N/mm Wood. Sbutterlng Modulus ofElasticity Amd.4 Ply, Decorative Laminate, [S 1734 (Part II): 83 (RA 2008) 500 N/mm2 to Veneered IS 1659: 2004 (RA 2009) 15000 N/mm' Decorative Amd.2 PlyWood

~. Poo)a Singh N. Venka!eswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T-1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 50f15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

Timber PaneUed Dimensions IS 2380 (Part 2): 77 (RA 2008) I mm to 2500 mm Materials Amd.l Block Boards, IS 4020 (Part 2): 98 (RA 2008) Plain Panide Amd.2 Boards, IS 2046: 95 (RA 20 I0) Pre -Laminated Amd.l Particle Board., Medium Den.ity Density IS 2380 (Part 3): 77 (RA 2008) 100 kg/m'lo 1000 kg/m' Fibre Boards, Amd.4 Pre-Laminated IS 1734 (Part I): 83 Medium (RA 2008) Density Fibre Boards, Linear Expansion and Thickness IS 2380 (Part 17): 77 0.01 mm t050 mm (t) Ply Wood, Swelling (Swelling in Water) (RA 2008) 0.01 mm to 300 mm(l) Timber Swelling in Thickness due to Amd.4 Wooden F1u.h Surface Absorption Doors Marine Ply Tensile Strength IS 2380 (Part 5): 77 (RA 2008) 0.0 I N/mm' to 5 N/mm' Wood, Shuttering Perpendicular 10 Surface I Amd.4 Ply, Decorative Internal Bond Laminate, Veneered Screw Withdrawal Strength IS 2380 (Part 14): 77 (RA 2008) ION to 5000N Decorative Amd.4 PlyWood IS 4020 (Part 16): 98 (RA 2008) Amd.2

Surface Abrasion IS 12823: 1990 (RA 2009) I to 3000 Resistance Amd.7 Revolutions IS 14587: 98 (RA 2009) Amd. 5 IS 2046: 95 (RA 2010) Amd. I

Resistance to Steam IS 12823: 1990 (RA 2009) Qualitative Amd.7 IS 14587: 98 (RA 2009) Amd. 5 IS 2046: 95 (RA 2010) Amd. 1

Poola Singh N. Venkateswaran Convenor Program Manager nflBL SCOPE OF ACCREDITAnON

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 60f15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Timber Panelled Resistance to Crack IS 12823: 1990 (RA 2009) Qualitative Materials Amd.7 Block Boards, [S 14587: 98 (RA 2009) Plain Particle Amd,5 Boards, IS 2046: 95 (RA 2010) Pre -Laminated Amd.1 Partide Boards, Medium Density Resistance to Cigarette Burn . IS 12823: 1990 (RA 2009) Qualitative Fibre Boards, Amd.7 Pre·Laminated IS 14587: 98 (RA 2009) Medium Amd.5 Density Fibre IS 2046: 95 (RA 2010) Boards, Amd. I Ply Wood, Timber Water Absorption IS 2380 (Part 16): 77 (RA 2008) 0.1 %t095% Wooden Flush Amd.4 Doors Marine Ply Surface Defects & IS 2046: 95 (RA 20 I 0) Qualitative Wood, Shuttering Surface Quality Amd. I Ply, Derorative [S 303: 1989 (RA 2008) Laminate, Amd.6 Veneered [S 1328; 96 (RA 2011) Decorative Amd.6 Ply Wood IS 710; 2010

Glue Shear Strength Test [S 1734 (Part 4): 83 (RA 2008) 0.1 kNto 10kN Amd.3

Resistance to Staining IS 12823: 1990 (RA 2009) Qualitative Amd.7 [S 2046; 1995 (RA 2010) Amd. I IS 14587: 1998 (RA 2009) Amd.5

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I. Kamla Nehru Nagar. Ghaziabad. Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 70f15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection eerformed

Timber Panelled Mycological Test IS 1659: 2004 (RA 2009) Materials Amd.2 Qualitative Block Boards, IS 1734 (Part 1): 83 (RA 2008) Plain Particle Amd. I Boards, Pre -Laminated Adhesion ofPlies IS 1659: 2004 (RA 2009) Qualitative Particle Boards. (Knife Test) Amd.2 Medium Density IS 4020 (Part 14): 98 (RA 2008) Fibre Boards, Amd. I Pre-Laminated IS 1734 (Part 5); 83 (RA 2008) Medium Density Fibre Boards. Tensile Strength IS 1734 (Part 9): 83 5 N/rnm'to J00 Nlmm' Ply Wood. (RA 2008) Timber Wooden Flush Resistance to Immersion in IS 2046: 95 (RA 20 I 0) 0.1 mm to 12 mm Doors Boiling Water Amd.1 Marine Ply WOOd. Shuttering Dimensional Stability at deviated IS 2046: 95 (RA 2010) 0.1 mm to 200 mm Ply. Decorative Temperature Amd.l Laminate, Veneered Resistance to Dry Heat at 180°C IS 2046; 95 (RA 2010) Amd. Qua litative Decorative PlyWood Resistance to Impact by Small IS 2046; 95 (RA 20 I0) Qualitative Di. Ball Amd.l

Resistance to Scratching IS 2046: 95 (RA 20 I 0) Amd. I Qualitative

II. Wooden Flush Slamming Test IS 4020 (Part 10): 98 (RA 2008) Qualitative Doors Local Planeness IS 4020 (Part 4): 98 (RA 2008) 0.05 mm to 10 mm Amd.2

Impact Indentation IS 4020 (Part 4): 98 (RA 2008) 0.05 mm to 10 mm Amd.2

Pooja Singh N. Venkateswaran Convenor Program Manager HABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad. Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T-1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 8 of 15

S. No. Product I Specific Test Performed Test Method Specification Range otTesting I MaterlalotTest against which tests are Limits of Detection performed

Wooden Flush Glue Adhesion Test IS 4020 (Part 15): 98 (RA 2008) 0 .01 mm to 150 mm Doors Amd,2

IS 4020 (Part (3): 98 (RA 2008) Qualitative End Immersion Test Amd.2

General Flatness IS 4020 (Part 3): 98 (RA 2008) 0.0 I mm to 10 mm Amd.2

Flexure Test IS 4020 (Part 6): 98 (RA 2008) 0,0 I mm to 100 mm Amd.2

Edge Loading Test IS 4020 (Part 7): 98 (RA 2008) 0 ,0 I mm to 25 mm Amd, 2

Shock Resistance Test IS 4020 (Part 8): 98 (RA 2008) Qualitative Amd, I

Buckling Test [S 4020 (Part 9): 98 (RA 2008) 0,0 I mm to 100 mm Amd, 2

Misuse Test IS 4020 (Part II): 98 (RA 2008) Qualitative Amd,2

Varying Humidity Test IS 4020 (Part 12): 1998 0,01 mm to [a mm (RA 2008) Amd. 2

II. METALLOGRAPHY TEST I. Ferrous Met.ls Macro Structure Examination IS 11371: 1985 Qualitative [S 12037: 1987 5. BSEN:I32I: 1997

2. Aluminum Coating Test IS 6012: 1992 12 Microns to 80 Microns Seetion (Instrument Method)

Pooja Singh N. Venkateswaran Convenor Program Manager "RBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025; 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on {l6.01.2016 Page 9 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material ofTest against which tests are Limits of Detection (!erformed

III. MECHANICAL PROPERTIES O~' MATERIALS l. Ferrous Material Tensile Test IS 3600 (Part 3): 2004 200 MPa to 800 MPa Weldments Bend Test IS 3600 (Part 5): 1983 Qualitative IS 3600 (Part 6): 1983 (5 mOl to 96 mm mandrel dial

Impact Test IS 1757: 1988 12 J to 240 J (-)50 °C to Ambient

2. Metal & Alloys Tensile Strength IS 1608: 2005 50 MPA to 1700 MPA (Ferrous, Yield Stress I 0.2% Proof Stress 40 MPA to 1400 MPA Nonferrous, Raw. % Elongation I %t080% Materials Reduction in Area 1%1080% Products) (1.5 kN to 1000 kN)

Bend Test IS 1599: 2012 Qualitative (Upto 32 mm)

Brinell Hardness Test IS 1500 (Part I): 2013 tOO HBW to 400 HI3W (51750)

Rockwell Hardness Test IS 1586 (Part I): 2012 100 HBWt0400 HBW (1013000) 20 HRBW to 100 HRBW

Vickers Hardness Test IS 1501 (Part I): 2013 20 HRC to 70 HRC 250 HV 3 to 750 HV 3

3. Ferrous Raw Izod Impact Test IS 1598: 1977 IJtol70) Matenals Charpy Impact Test IS 1757: 1988 2Jto 300) Ambient to 40 ·C

Poola Singh N. Venkateswaran Convenor Program Manager NflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T-1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 10 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

4. Ferrous Pipes Compression Test IS 9537 (Part I): 1980 Qualitative Flattening Test IS 2328: 2005 Qualitative Crushing IS 3601: 2006 Qual itative Bend Test For Metallic IS 2329: 2005 Qualitative Bend Test For Conduit IS 9537 (Part 2): 1981 Qualitative Drift Expansion IS 2335: 2005 Qualitative

5. High Strength Re-Bend Test IS 1786: 2008 Qualitative Oeformed Stee[ Oar

6. Ferrous Wi~s & Wrapping Test IS 1755: 1983 Qualitative Rods Upto 3 mm Reverse Bend Test IS 1716: 1985 Qualitative

7. Ferrous Steel & . 0.2 % Proof Load IS 14268: 1995 1.5 kN to 1000 kN Ply Strand Breaking Load IStrength 1.5 kN to 1000 kN % Total Elongation at Gauge Length

8. Ferrous & Dimension IS 1239 (Part I): 2004 0.01 mm to 150mm Nonferrous (Bars, Amd. 4: 2010 Min. 0.01 rum Wires, Pipes, IS 1161: 1998 (RA 2009) Tubes, Valves, Amd. 5: 2012, Sheets) IS 1785 (Part I): 1983 (RA 2009) IS 1785 (Part 2): 1983 Amd. 4: 2004 IS 1786: 2008 Amd. I: 2012 IS 3589: 2001 (RA 2009) IS 3601: 2006 IS 2062: 2011 Amd: 2012 [S 4270; 2001 (RA 2006) Amd.2006 IS 778: 1984 (RA 2005) IS 4923: 1997 (RA 2009) IS 9537 (Part 2): 1981 (RA 2007)

N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 11 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Teet against which tests are Limits of Detection performed

9. Pipe TMT I HSD Mass IS 1239 (Part I): 2004 0.5glo 15kg Bars (RA 2010) L.C: 0.5 g

IS 1161: 1998 Amd. 4: 2011

[S 1786: 2008 (RA 2008)

IS 3589: 2001, Amd. 3: 2006, (RA 2006)

IS 360 I: 2006

IS 2062: 2011, Amd. I: 2012

IS 4270: 2001 (RA 2006) Amd. I: 2006

[84923: 1997 Amd. I: 1998

IS 9537 (Part I): 1980, (RA 2007) Amd. I: 1995

10. Gate Valves, Hydraulic Pressure Test IS 778: 1984, Amd. 3: 2005 Qualitative G lobe Valves, Check Valves and OthenValves For Water Works Purposes, M.S. Tubuler& Other Steel Fillings

II. Transformer Air Pressure Testl Vacuum Test IS 1180 (Part I): 1989 & Qualitative Tank IS 1180 (Part 2): 1989 (RA 2003)

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar pradesh

Accreditation Standard ISOIIEC 17025: 2005

DIscipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T-1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 12 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which teste are Limits of Detection performed

12. TMTlHSDBar Pullout Test IS 2770 (Part I): 1967 Qualitative (RA 2007)

13. Steel Pipe I Tub•• Workmanship IS 1239 (part I): 2004 Qualitative (Upto 150 mm I Finish (Visual [nspeetion) Amd. 4: 2010 Nominal Size) [S 1161: 1998 Amd. 4: 2010

[V. PLASTIC, RUBBER AND LEATHER I. Rubber Hardness By Durometer method 35 to 95 (Shore A) ASTM 02240: 05 (2010)

Tensile Strength IS 3400 (Part I): 1987 5 N/mm'to 30 N/mm' (RA 2012)

Elongation IS 3400 (Part I): 1987 110%t09OO% (RA 2012)

Compression Set IS 3400 (Part 10): 1977 Ot060 % (RA 2003)

2. Plastics Opacity IS 12235 (Part 3): 2004 o to I % transparency

Viea! Softening Point IS 12235 (Part 2): 2004 50'C to 120'C

Reversion Test IS 12235 (Part 5): 2004& 25'C to 200 'C IS 4984 Annexure C

Density IS 12235 (Part 14): 2004 0.9 g/em' to 1.8 glem'

Carbon Black Dispersion IS 2530: 1963 (RA 2003) Ixto200x (Qualitative)

Carbon Black Contents IS 2530: 1963 (RA 2003) O.QI % to 4 %

N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N,R,), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14,10,2015

Certificate Number T·1029 Valid Until 13,10,2017

Last Amended on 06.01,2016 Page 13 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

PI.stics Melt Flow Index IS 2530: 1963 (RA 2003) (0.1 gt04g)!IOmin.

Resistance to External Blows IS 4985: 2000 0.25 kg to I kg. AnnexureC (Qualitative)

Hydrostatic Pressure Test [S 12235 (Part 8): 2004 & 1 kg/em' to 55 kg/em' IS 4984: 1995 Annexure B (Qualitative)

Dimensions of Pipe [S 12235 (Part 1): 2004 I mm to 600 mm.

Sulphated Ash [S 4985: 2000 Annexure B 0.1 %to 15%

y, MATERIALS 1. (Fabric) Weight IS 1964: 200 I (RA 2000) 20 GSM to 250 GSM

Threads Per Unit Length in IS 1963: 1981 (RA 2004) 5 to 100 (Ends, Picks) (per em.)

Breaking Load [S 1969: 1985 (RA 2006) 50 N to 2000N

Length & Width of Fabric IS 1954: 1990 5 em to 700 em. (RA 2004)

2. Paper Gloss! Opacity! Brightness IS 1060 (Part I & Part 2): 1966 Ota 100% (RA 2004) Amd. 5: 2011

One Minute Cobb test for water IS 1060 (Part I): 1966 15 to 90 penetration (RA 2004) Amd. 5: 2011

Tensile Index IS 1060 (Part I): 1966 10 Nmlg to 100 Nmlg (RA 2004) Amd. 5: 20 II

Moisture Content [S 1060 (Part I): 1966 l %to50% (RA 2004) Amd. 5: 2011

Pooja Singh N. Venkateswaran Convenor Program Manager HfiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R." Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T-1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 14 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection eerformed

Paper Surface Strength Dennison IS 1060 (Part 1): 1966 2 A to 22 A wax picks (Wax Pick) (RA 2004) Amd. S: 2011 (Qualitative)

Ash Content IS 1060 (Part I): 1966 1 %t050% (RA 2004) Amd. 5: 20 II

Weight IS 1060 (Part I): 1966 10 GSM to 400 GSM (RA 2004) Amd. 5: 2011

Thickness IS 1060 (Part I): 1966 10 micron to 500 micron (RA 2004) Amd. 5: 2011

Stiffness IS 1060 (Part 3): 1966 0.5 to 5 (Taber Stiffness) (RA 2004) Amd. 5: 2011

Tear Index IS 1060 (Part 1): 1966 0.5 mNm'/g to (RA 2004) Amd. 5; 2011 20 mNm'/g

Bursting Strength IS 1060 (Part I): 1966 5 kg/cm'to 20 kg/cm'. (RA 2004) Amd. 5: 2011

Double Fold (Folding Endurance IS 1060 (Part I): 1966 5 nos to 100 nos. Tester) (RA 2004) Amd. 5: 2011

Smoothness & Porosity IS 9894: 1981 40 mg/ml to 2900 mg/mL (Bendtsen Type)

VI. Conslruction Compressive Strength IS 516: 59 (RA 2008) Amd. 2 0.5 N/mm'to 80 N/mm' Water Setting Time IS 4031 (Part 5): 88 (RA 2009) 10 min to 700 min Amd.2

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh Accreditation Standard ISOIIEC 17025: 2005

Discipline Mechanical Testing Issue Date 14.10.2015

Certificate Number T·1029 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 15 of 15

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

VII. SOIL & ROCK TESTING

I. Soil Sieve Analysis IS 2720 (Part I): 1983 45 ~ to 75 mm (RA 2010)

Atterberg Limits:· Liquid Limit IS 2720 (Part 5): 1985 5 %to 50 % (RA 2010)

Plastic Limit IS 2720 (Part 5): 1985 5 %to 50 % (RA 2010)

Moisture Content IS 2720 (Part 2): 1973 0.1 %to 50% (RA2010) Amd. 1

California Bearing Ratio (CBR) IS 2720 (Part 16): 1987 I %t0200% (RA 2011)

Optimum Moisture Content and IS 2720 (Part 2): ]973 0.1 to 50% Dry Density:­ (RA 20]0) Amd. 2

.) Light Compaction ]S 2720 (Part 7): ]980 0.5 glee to 3 glee (RA 2011) Amd. 2

b) Heavy Compaction ]S 2720 (Part 8): 1983 0.5 glee to 3 glee (RA 20]0) -x·x-x-x-x-x-x-x-x-x-x-x-x-x-

Pooja Singh N. Venkateswaran Convenor Program Manager NflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T-0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 1 of 11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Datection performed

I. BUILDING MATERIALS I. Cement Lime content IS 4032: 1985 (RA 2009) 30%1070% 33-grade OPC Amd. No.2: March 2010 43-grade 0 PC Iron oxide OJ %to IS % 53·grade OPC SRC-Cement Alumina 0.3 %to 30 % PPC-Cement Slag Cement Sulphuric anhydride 0.5 %104% White Cement Magnesium oxide 0.05 %to 10%

Ch loride content 0.01 %to J %

Insoluble residue 0.1%1035%

Loss on ignition 0.1 %to 10%

Sulphide sulphur 0.1 %to 3 %

Silica centent 0.3 %to 70 %

II. METALS & ALLOYS I. Metal Carbon IS 228 (Part 1): 1987 (RA 2008) 0.05 % to 2.5 % (Low Alloy Steel Tool Steel, . Manganese IS 228 (part 2): 1987 (RA 2008) 0.1 %to 1.0% Carbon Steel, Silicon IS 228 (Part 8): 1989 (RA 2009) 0.1 %to 2.0 % TMT) Sulphur IS 228 (Part 9): 1989 (RA 2009) 0.01 % to 0.25 %

Phosphorus IS 228 (Part 3): 1987 (RA 2008) 0.01 % to 0.25 %

Chromium IS 228 (Part 6): 1987 (RA 2009) 0.1 %t08.0%

Nickel IS 228 (Part 5): 1987 (RA 2009) 0.1 %t02.0%

PooJa Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard IsonEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 20f11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test allainst which tests are Limits of Detection performed

2. Stainless Steel Carbon IS 228 (Part 1): 1987 (RA 2008) 0.05 % to 1.0 %

Manganese IS 228 (Part 2): 1987 (RA 2008) 0.5 % to 3.0 %

Silicon [S 228 (Part 8): 1989 (RA 2009) 0.1 % to 5.0 %

Sulphur [S 228 (Part 9): 1989 (RA 2009) 0.0 I % to 0.25 %

Phosphorus IS 228 (Part 3): 1987 (RA 2008) om % to 1.0 %

Chromium IS 228 (Part 6): 1987 (RA 2009) 8.0 % to 22.0 %

Nickel IS 228 (Part 5): 1987 (RA 2009) 5.0 % to 12.0 %

Molybdenum IS 228 (Part 7); I989(RA2009) 0.10%103.0%

3. Aluminum Metal Silicon (S 504 (part I) CI.7 0.3 % to 1.3 % and Its Alloys Magnesium NTHISOP/IO/CMlMETAU020 NA Date ofissue: January 2003 Issue no. 3

4. BrassIBronze Lead IS 4027 (Part 1): 1987 3%1010%

Nickel [S 4027 (Part 4): 1987 0.1 %to3%

Silicon IS 4027 (Part 10); 2000 0.01 %t05.0%

Iron SOPll'e NA

Copper IS 4027 (Part I): 1987 50%1085 %

Phosphorous (S 4027 (Part 3); 1987 O.ot % to 3.0 %

Pooja Singh N. Venkateswaran Convenor Program Manager HABL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 30f11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

s. G.r. Metal Mass of zinc coating. IS 6745: 1972 (RA 2006) 50 gmlm' to 800 gmlm' (Sheet, Wires, IS 4736: 1986 (RA 2006) Pipes, Channels, Strips, Coils) Uniformity ofzinc coating. IS 4826: 1979 (RA 2006) Qualitative IS 2633: 1986 (RA 2006) IS 4759: 1996 (RA 2006)

6. Aluminum Thickness ofanodic coating. IS 5523: 1983 (RA 2006) 2.0 microns to 35 microns S.etion IS 1868: 1996 (RA 2006)

III. PAINTS AND SURFACE COATING I. Enamel Paint Drying Time IS 10 I (Part 3/Sec J): 1986 2 hrs to 24 hrs (! Under Coating) Colour IS 101 (Part 4/Sec II): 1989 Qualitative IS 5: 2007

Consistency IS 101 (Part IISec V): 1989 50 s to 200 s

Fineness ofgrind (microns) IS 101 (Part 3/Scc IX): 1987 10 microns to 100 microns

Finish IS 101 (Part 3/Sec IV): 1987 Qualitative

Gloss 60' IS 101 (part 4/Sec IV): 1988 50'to90"

Mass in kg/IOL IS 101 (Part IISeeVII): 1987 (5 kg to 20 kg)/IO L

Fastness to Light IS 101 (Part 4/Sec III): 1988 Qualitative

Scratch hardness test IS 101 (Part 3/Sec V): 1987 Qualitative

Flexibility.& adhesion test IS 101 (Part SISce 11): 1988 Qualitative

Resistance to water IS 101 (Part 71Sec I): 1989 Qualitative

~.-- ~Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 4 of 11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Enamel Paint Flash point [S 101 (part IISee VI): 1987 30 'C to 70 'C (Finishing! Under Coating) Wet opacity IS 101 (Part 4/Sec I): 1988 (80 m' to 300 m' )il 0 L Volume solids [S ,101 (part S/Sec,VI): 1993 10%1050 %

Accelerated storage stability test IS 133 Annexure E [S 2932 Annexure G Qualitative IS 8662 Annexure F

Application properties [S 2932 Clause, 6,6 Qual it.tive IS 8662 Clause, 6,2.6

Lead-restricted material IS 101 (Part 81Sec V): 1993 0.1 % to 1.0 % (Lead Content)

Phthalic .nhydride IS 101 (Part 8/Sec IV): 1993 8%t030%

Viscosity by ford cup IS 10J (Part IISce V): 1989 40sto 1505

Non Vol.tikMatter [S 10 I (Part 2/Sec Ill: 1986 10 to 50

Resistance to Acid IS 2932 (Part I): 2013, Qualitative Annexure B, IS 8662: 2004 Clause. 6.4 Resistance to Alkali IS 2932 (Part I): 2013 Qualitative Annexure F IS 8662: 2004 Clause, 6,5

Freedom from Yellowing IS 133: 2004 Clause, 5.7 Qualitative

2. Ready Mixed Lead-Content (Lead Restriction) IS 101 (Part 81Sec V): 1993 0.1 %to 1.0% Paint (Zinc Clause 3 Chrome Primer) Consistency IS 101 (Part lISec V): 1989 [Oslo 180s

Pooja Singh N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar. Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 5 of 11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Ready Mixed Resistance to Salt Spray IS 2074: 1992 Qualitative Paint (Zinc Chrome Primer) Water content IS 10 J (Part 21Sec I): 1988 0.2 %to 1.0 %

Drying Time IS 101 (Part 31Sec I): 1986 I hrS to 24 hrS

Finish IS 101 (Part 31Sec IV): 1987 Qualitative

Fineness of grind IS 101 (pa.rt3ISecV): 1987 10 Micron to 100 Micron

Gloss at 4S" and 60' IS 101 (Part 41Sec VI): 1988

Colour IS 101 (Part 41Sec II): 19891 Qualitative IS S: 2007

Mass in KgllOL IS 101 (Part IISce VII): 1987 {S kg to 20 kg)110 L

Scratch hardness test IS 101 (Part 51Sec I): 1987 Qualitative

Volume solids IS 101 (Part 81Sec VI): 1993 Qualitative

Flexibility & adhesion test IS 101 (Part SISec II): 1988 Qualitative

Protection against Corrosion [S 101 (Part 61See f): 1988 Qualitative under condition of condensation

Flash point [S 101 (part IISee VI): 1987 30°C to 70 'C

Accelerated storage stability test IS 2074: [992 Annexure E Qualitative IS 13607: 1992 Annexure C

Pigment Content IS 101 (part SISec II): 1990 10 % to 6(1";"

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I. Kamla Nehru Nagar. Ghazlabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 6 of 11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are limits of Detection performed

Ready Mixed Pigment Composition Paint (Zinc Chrome Primer) Zinc Oxide IS 2074: 1992 Annexure B 2%to 15%

Chromic Anhydride IS 2074: 1992 Annexure B 2%t025%

Iron Oxide IS 44: 1979 5%t080%

3. Aluminum point Form & Condition IS 289: 1963 Qualltatlvc

Consistency IS 101 (Part II Sec V): 1989 50sto 150s

Residue on sieve IS 101 (Part 81 Sec I): 1989 0,2%t03%

Drying time IS 101 (Part 31 Sec I): 1986 2 hrs to 20 hrs

Finish IS 101 (Part 31 Sec [V): 1987 Qualltative

Grease content IS 289: 1963 0,1 %t04%

Protection against corrosion IS 101 (Part 61 Sec I): 1988 Qualitative under condition of condensation

Flash Point IS 101 (Part 1/ Sec VI): 1987 20 OCto 70 'C

Volatile matter IS 101 (Part 2/ Sec II): 1987 10 % to 60 %

Mass in kg/I OL [S 101 (Part II Sec VII): 1987 (2 kg to 15 kg)IIO L

Leafing valuc IS 289: 1963 10%t080%

Flexibility & adhesion test IS 101 (Part 5/ Sec II): 1988 Qualitative

Wet opacity [S 101 (Part 41 See I): 1988 (50 m' to 350 m'/IO L

Pooja Singh N. Venkateswaran Convenor Program Manager "ABL SCOPE OF ACCREDITAnON

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025; 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T-0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 7 of 11

S. No. Product! Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

4. Varnish Resistance to water IS 101 (Part7ISecl): 1989 Qualitative

Acid value IS 101 (Part 9/Sec 1): 1993 2 tolO

Scratch hardness test IS 101 (Part 5/Sec I); 1987 Qualitative

Flash peint [S j 0 j (Part lISee VI): 1987 10°Cl040'C (Qualitative)

Drying time IS 101 (Part 3/S•• I); 1986 30 min to 8 hrs

Finish [S 101 (Part3/Sec IV); 1987 Qualitative

Volatile matter [S 101 (Part 2/See II); 1986 20%t070%

Flexibility & adhesion test IS 101 (Part 5/Sec II); 1988 Qualitative

Viscosity IS 101 (Part lISee V); 1989 0.2 to 2.0 Slakes

5. Ready Mixed Resistance to heat [S 158: 1981 Qualitative Paint Bituminous, Brushing, Black Volatile matter [S 101 (Part 21See II): 1986 10%1060% Japan Consistency IS 101 (part IISee V): 1986 50sto 150.

Resistance to acid IS 158: 1981 Qualitative [S 9862: 1981

Water content IS 101 (Part USee I); 1988 0.2 %to 1.0 %

Drying time [S 101 (Part 3/See I); 1986 2 hrs to 18 hr. (Qualitalive)

Poola Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 8 of 11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Ready Mixed Wet opacity (S 101 (Part4lSec I): 1988 (80 m' to 350 m')/IO I Paint Bituminous, Brushing, Black Finish IS 101 (Part 3/Sec IV): 1987 Qual itati ve Japan Resistance to alkali IS 158: 1981 . Qualitative IS 9862: 1981

Resistance to chlorine IS 9862: 1981 Qualitative

Colour IS 101 (Part4lSec II): 1987 Qualitative

Mass IS 101 (Part lISec Vll): 1987 (8 kg to 20 kg)110 L

Resistance to waler IS 10 I (Part 7/Sec 1): 1989 Qualitative

Flexibility & adhesion test IS 101 (Part SISec II): 1988 Qualitative

Protection against corrosion IS 101 (Part 61See I): 1988 Qualitative under conditions ofcondensation

Flash point IS 101 (Part IISec VI): 1987 20 OCto 70°C (Qualitative)

Stripping test IS 101: 1964 Qualitative

Lead content IS 101 (Part 8ISee V): 1993 0.05 % toO.1 %

Resistance to kerosene IS 341: 1973 Qualitative

Ash content IS 341: 1969 0.1 %t05 %

Reaction with white paint IS 341: 1973 Qualitative

Reaction with varnish IS 341: 1973 Qual itat; ve

Pooja Singh N. Ven katesWllran Convenor Program Manager nflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T·0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 9 of 11

S. No. Product / Specific Test Performed Test Method Specification Range of Testing / Material of Test against which tests are Lim its of Detection performed

IV. WATER 1. Water for Colour IS 3025 (Part 4): 1983 1.0 Hazen to 100 Hazen Drinking Purpose (RA 2006) Cobalt method Packaged Drinking Water Odour IS 3025 (Part 5): 1983 Qual itati ve Packaged Natural (RA 2006) Mineral Water Turbidity, NTU IS 3025 (Part 10): 1984 0.1 NTUla l000NTU (RA 2006)

pH IS 3025 (Part II): 1984 0.1 mgllto 13.9 (RA 2006)

Total Hardness IS 3025 (Part 21): 1983 2 mg/lto 1000 mg/I (RA 2006) EDTA Method

Iron IS 3025 (P.rt 2):2004 0.005 mg/I to 10 mg/I ISO 11885 :1996 EPA(ICP) method 00.5

Chlorides IS 3025 (Part 32): 1988 2 mg/I to 1500 mg/I (RA 2009) Argontometrie Method

Tot.1 Dissolved solids IS 3025 (Part 16): 1984 5 mg/I to 1500 mg/I (RA 2002)

Caleium

Magnesium (as Mg) IS 3025 (Part 2): 2004 0.02 mgll tolOO mgn (SO 11885: 1996 EPA(ICP) method 200.5

Pooja Singh N. Venkateswaran Convenor Program Manager nflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T-0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 10 of 11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Malerialof Test against which tests are limits of Detection performed

Water for Copper (as Cu) IS 3025 (Part 2): 2004 0,005 mgll tolO mg/l Drinking Purpose ISO 11885: 1996 Packaged EPA(ICP) method 200.5 Drinking Water Packaged Natural Sulfates IS 3025 (part 24): 1986 10 mgll to 500 mgll Mineral Water (RA 2003) Gravimetric

Fluoride APHA (22" Edition) 0,1 mg/l to 100 mg/l 4500 -F'C Ion selective method

Cyanide IS 3025 (Part 27): 1986 0,001 mgll to 10 mg/I (RA 2009) Ion Selective Electrode

Total Chromium IS 3025 (Part 2): 2004 0.005 mgll to I 0 mg/I ISO 11885: 1996 EPA(ICP) method 200.5

Manganese (as Mn) IS 3025 (Part 2): 2004 0.005 mg!1 to 10 mg/I ISO 11885: 1996 EPA(ICP) method 200.5

Selenium (as So) IS 3025 (Part 2): 2004 0,002 mg/I to 10.0 mg/I ISO 11885: 1996 EPA(ICP) method 200.5

Arsenic (as As) [S 3025 (Part 2): 2004 0.005 mg/I to 10,0 mg!1 ISO 11885: 1996 EPA(ICP) method 200.5

Lead (as Pb) [S 3025 (Part 2): 2004 0.005 mgll to 10.0 mg/I ISO 11885: 1996 EPA(ICP) method 200,5

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Chemical Testing Issue Date 14.10.2015

Certificate Number T-0204 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 110f11

S. No. Product I Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Water for Cadmium (as Cd) IS 3025 (Part 2): 2004 0.005 mg/I to 10 mg/I Drinking Purpose ISO 1I885: 1996 Packaged EPA([CP) method 200.5 Drinking Water Zinc [S ;3025 (Part 2): 2004 0.005 mg!1 to 10 mg/I Packaged Natural [SO 11885: 1996 Mineral Water EPA(ICP) method 200.5 Boron/Borates IS 3025 (Part 2): 2004 0.005 mgll to 50 mgll ISO [1885: 1996 EPA([CP) method 200.5 2. Water for Alkalinity IS 3025 (Part 23): 1986 0.1 mlto loomlof Construction (RA 2009) Titrimetric 0.02 N H,SO, Purpose Acidity IS 3025 (Part 22): 1986 0.1 mlto 10mlof. (RA 2009) 0.02 N NaOH Inorganic Solids IS 3025 (Part 18): 1984 10 mgll to 4000 mgll (RA 2006) Gravimetric Orsanic Solids IS 3025 (Part 18): 1984 5 mgll to 500 mgll (RA 2006) Suspended Matter IS 3025 (Part 18): 1984 5 mgll to 2500 mgll (RA2006) Sulphate (as SO,) [S 3025 (Part 24): 1986 5 mg/I to 1000 m gil (RA 2003) Gravimetric Chloride (as CI) IS 3025 (Part 32): 1988 2 mg/I to 4000 mg/I (RA 2009) Argontometric pH IS 3025 (Part I I): 1984 0.1 to 13.9. (RA 2006) -x-x-x-x-x-x-x-x-x-x-x-x-x-x-

NOTE: The Laboratory has demonstrated competence for the stated scope for WATER. This however docs not fully cgver the spe<;ification requirements of BIS for the Packaged Drinking Water as per IS 14543 and the Packaged Natural Minerai Water IS 13428.

Pooja Singh N. Venkateswaran Convenor Program Manager HflBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.I, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

Discipline Biological Testing Issue Date 22.04.2016

Certificate Number T-3207 Valid Until 13.10.2017

Last Amended on Page 2 of 2

S. No. Productl Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

Packaged Natural Salmonella IS 5887 (Part 3): 1999 (RA 2003) Qualitative Mincl'lIl Water & Clausc 9 (Present/Absent) per 250 011 I'Rckaged IS 15187: 2002 (RA 2007) Drinking Water Clause S (Other than Packaged Natural Shigella IS 5887 (Part 7): 1999 (RA 2005) Qualitative Mineral Water) Clause 7, 8 (Presenl/Absent) pcr 250 ml

Vibrio cholcrac IS 5887(Part 5): 1976 (RA 2005) Qualitativc Clause 5.1, 6 (Present/Absent) per 250 ml

Vibrio parahacmalyticus IS 5887 (Part 5): 1976 (RA 2005) Qualitative Clause 5.2, 6 (Prescnt/Absent) per 250 1111

Aerobic Microbial Count IS 14543: 2004 at37°C in 24 h [S 5402: 2012 :s 20 CFUlml at 37°C in 24 h at 20 to 22 °C in 72 h Clause 9 :s 100 CPUlml at 20°C to 22 °C in 72 h -x-x-x-x-x-x-x-x-x-x-x-x-x-x-

NOTE: The Laboratory has demonstrated competence for the stated scope for WATER. This however does not fully covel' the specification requirements orBiS for the Packaged nrinking Watcr a. pcr IS 14543 and tbe PAckaged Nul.ral Mineral Water IS 13428.

Pooja Singh N. Venkateswaran Convenor Program Manager HfiSL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISO/IEC 17025: 2005

Discipline Biological Testing Issue Date 22.04.2016

Certificate Number T·3207 Valid Until 13.10.2017

Last Amended on Page 10f2

S. No. Product / Specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

I. Drinking Water E. coli IS 1622: 1981 Qualitative (Present/Absent) per 100011

Total Coliform Bacteria IS 1622: 1981 Qualilalive (ProsellilAbsent) pcr 100mi

2. I'aekaged Natural Il.eoli IS 5887 (Part I): 1976 (RA 2005) Qualitative Mineral Water & Clause 5, 6 (Prescnt/Absellt) per 250 ml I'aekaged [S 15185:2002 IJrinking Water Clause 8 (Other than l)ackagcd Naturul Coliform Bacteria IS 540 I (Part I): 2002 Qualitative Mineral Water) Clause 9 (l'rescnilAbsent) per 250 1111 IS 15185; 2002 Clause 8

Faecal streptococci IS 5887 (Part 2); 1976 (RA 2009) Qualitative Clause 8.2.1, 6.2 (PrcsenilAbsent) per 250 ml IS 15186: 2002 (RA 2007) Clause 8

Staphylococcus aurcus IS 5887 (Part 2): 1976 (RA 2009) Qualitative Clause 5, 6.[ (Presentl Absent) per 250 1111

Sulphite Reducing anaerobes [S 13428: 2005 Qualilative Clause C-4.7 Annexure C (i'rcscnilAbscnt) per 50ml

Pseudomonas acruginosa IS 13428: 2005 Qualitative Clause 0-7, D-8 (I'resentl Absent) per 250 1111

Ycast and Mould IS 5403: 1999 (RA 2005) Qualitative Clause 9 (Present/Absent) per 250 1111

Pooja Singh N. Venkateswaran Convenor Program Manager "flBL SCOPE OF ACCREDITATION

Laboratory National Test House (N.R.), Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh

Accreditation Standard ISOIIEC 17025: 2005

. Discipline Non - Destructive Testing Issue Date 14.10.2015

Certificate Number T·1030 Valid Until 13.10.2017

Last Amended on 06.01.2016 Page 1 of 1

S. No. Product! specific Test Performed Test Method Specification Range of Testing I Material of Test against which tests are Limits of Detection performed

I. METALS AND ALLOYS I. Metallic X·Ray Radiography IS 1182: 1983 (RA 2010) 5 mm to 40 mm ofsteel Malerials IS 2595: 2008 thickness (Welds and ASTM E·94: 2004 Qualitative Castings) ASTM E-1032: 2006 ASTM E-1030: 2005 IS 4853: 1982 (RA 2003) BS EN1435: 1997 (RA 2008)

2. Metallic Ultrasonic Testing IS 3664: 1981 (RA 1998) Weld·IO mm to 60 mm Malerials (Contact Method) IS 4225: 2004 Piate-IO mm to 60 mm (Welds Plate IS 4260: 2004 Forging-I 0 mmto Forgings) IS 8791: 1978 (RA 2003) 1000 mm BS£N 1714: 1997 Qualitative ASTM E-1l4: 2010 ASTM £-164: 2008 -x-x-x-x-x-x-x-x-x-x-x-x-x-x-

Poola Singh N. Venkateswaran Convenor Program Manager BIS RECOGNISED TESTING FACILITIES

• u

• DATA ON OUTSIDE RECOGNISED LABORATORIES w.e.f: from 2016-10-27 to 2019-10-26 Annex-I

6SLCODE 8101304 CONTACT; The Director National Test House INRI NAME TELEPHONE; 0120·2789906 ADDRESS Komia Nehru Nagar FAX: E·mall nlhnr·[email protected] Gha.labad 201002 REMARKS Updated on 14.03.2017 uttar Pradesh IS Number Product Testing Charge Remark -- 15 1331Part 1): 2013 ENAMEL,INTERIOR(A) Rs.l00001· UNDERCOATING (B) FINISHING

2 IS 158: 2015 READY MIXED PAINTS· R•.5()OOI. for chemical BRUSHING, BITUMINOUS, BLACK LEAD FREE, ACID, ALKALI AND HEAT RESISTING

3 15269 : 2015 ORDINARY PORTLAND CEMENT R•.l0ooOl· [Rs.60001· for Physical, For: 33, 43, 53, 435 Rs.40001· for Chemical] & 53SGredes

4 15277: 2003 GALVANISED STEEL SHEETS RS.40001· IRs.2000l· for Physical, Rs,20001· for Chemical]

5 15278: 2009 GALVANISED STEEL BARBED Rs,8000!· [R• .40001- for Physical, WIRE FOR FENCING Rs.40001- for Chemical)

8 IS 303: 1989 PLYWOOD FOR GENERAL 130001- for physical PURPOSES

7 IS 318: 1981 LEADED TIN BRONZE INGOTS Rs,75001- [Rs,4500!· for Physical, AND CASTINGS Rs.30001- for Chemical)

8 IS 319: 2007 FREE CUTIING BRASS BARS, Rs,50001- [ Rs.300Ot-for Physical, Included w.e,f. RODS AND SECTIONS Rs.20001- for Chemical) 07.02,2017

9 IS 341 : 1973 BLACK JAPAN Rs,80001- for chemical

10 IS 368: 2014 ELECTRIC IMMERSION WATER Rs.l0000 Included w.e.!. HEATERS 07.02.2017

11 IS 371 : 1999 CEILING ROSES RO.60001·

12 IS 374: 1979 ELECTRIC CEILING TYPE FANS R,,50001- tor 1 fan, 150001· for 3 fans AND REGULATORS

13 IS 383: 2016 COARSE AND FINE AGGREGATE I) Coarse Aggregate: Rs.180001· FROM NATURAL SOURCES FOR [Rs.l500Ot- for Physical, RS.30001· for CONCRETE Chemical): II) Fine Aggregate: Rs.11 0001­ [Rs,SCOO/· for Physical, Rs,3QOO/· for Chemical]

14 IS427 : 2013 DISTEMPER, DRY Rs.5()OOI- For Chemical Included w.e.!, 07.02,2017

15 IS 428 ,2013 DISTEMPER, OIL EMULSION Rs,5000/- for chemical

16 IS 432(Part 1): 1982 MILO STEEL AND MEDIUM Rs.SOOOI- [Rs,55001- for Physical, TENSILE STEEL BARS RS.25()0/· for ChemicaQ

17 IS 432(Part 2): 1982 HARD DRAWN STEEL WIRE FOR Rs.S500l- [Rs.550Ot- for Physical, CONCRETE REINFORCEMENT RS.10001· for Chemical]

18 IS 455: 2015 PORTLAND SLAG CEMENT RS.l00001· [Rs.6000/- for Physical, Rs.40001- for Chemical)

19 IS 456: 2000 CODE OF PRACTICE FOR PLAIN Ro, 110001- IRs.SOOOI- for Physical, Water for construction AND REINFORCED CONCRETE Rs,50001- for Chem",al); RS.1200I-for purposes cement concrete cube

20 IS 513: 2008 COLO ROLLED LOW CARBON For CR1: Rs, 10000/- [Rs,75001- for CR1, CR2 8, CR3 STEEL SHEETs & STRIPS Physical, Rs.250Ot- for Chemical); For grade. only CR2 8, CR3: Rs,120001- [Rs.95001- for Physical, Rs.2S001- for ChemlceQ

21 IS 694: 2010 PVC INSULA TEO CABLES Rs.20000!- for single core cable, For Category 01 only R'.2000/- for each extra co",

Page 1 14-Mar·17 tS Number Product Testing Charge Remark · --_._------

22 is 710, 2010 MARiNE PLYWOOD RS.2101JOl· [Rs,170001·lor Physical, Rs.4000/· for Chemical]

23 IS 778 : 1984 COPPER ALLOY GATE, GLOBE Rs,70001'1 RsAOOOI·for Physical, AND CHECK VALVES FOR RS.30001· IOf Chemicaij WATER WORKS PURPOSES 24 IS 814: 2004 COVERED ELECTRODES FOR il ERXXXX-grade per size: MANUAL ARC WELDING OF Rs, 145OO1·(for two size RS.290001· CARBON AND CARBON three size Rs.36500/- four size MANAGANESE STEEL RsAOOOO/-), For physical Rs.110001-, Radiography test RS.1000/-, For chemical Rs.25001­

Ii) lor EB XXXXHJX grade per size Full lest (EB XXXX grade): Rs.18000/·(for two size Rs.360001· three size Rs.445001- four size Rs.50oool.) , Diffusible hydrogen test~Rs.5OOOI~. Bend test-Rs,8000/~, Running performance test-Rs_2000/~, Increase mental recover test-Rs.3000l·

For physical Rs. 13000/~, Radiography test·:Rs.l000/·, For chemical RsAOOOI­

25 IS 1079: 2009 HOT ROLLED CARBON STEEL Rs,90001· I Rs.6500J.for Physical, SHEET AND STRIP Rs.25001· for Chemical]

/ 26 IS 1161 : 2014 STEEL TUBES FOR Rs.9000/·1 Rs,500OJ·lor Physical, STRUCTURAL PURPOSES Rs.400OJ- for Chemical]

27 IS 1180(Part 1): 2014 OUTDOOR TYPE OIL IMMERSED Rs.45000 for withOut tap, Included w.eJ. DISTRIBUTION TRANSFORMERS Rs,SOOOO for transformer with 4 tap, 14.03.2017. UPTO AND INCLUDING 2500 Rs.55000 for transformer with 7 tap, Above 200 KVA only. KVA, 33 KVA SPECIFICATION RS.6S000 for transformer with 9 tap. Excluding: CI.21.4(b)­ PART 1 MINERAL OIL IMMERSED Short circuit withstand lest.

28 IS 1237: 2012 CEMENT CONCRETE FLOORING Rs.7ooo1- For Physical TILES

29 IS 1239(Part 1): 2004 Steel Tubes, Tubulars and other RS.l0000/· [ Rs.eOOO/·for Physical, For plaIn ended only wrought steel fittings· Part 1 : RsAOOOI· lor Chemical] Steel Tubes

30 IS 1239(Part2): 2011 Mild Steel Pipe Fittings Rs.25OO/. [Rs,15001-lor Physical, For plain ended only Rs.1000/~ for Chemical}

31 IS 1293: 2005 PLUGS AND SOCKET OUTLETS Rs.7000/· lor plug & socket M, OF RATED VOLTAGE UPTO AND 2401250V, INCLUDING 2S0V AND RATED RS.looo0/· lor plug & socket leA, CURRENT UPTO leA 24OJ250V, Rs.120001· lor plug & socket 6116A, 2401250V

32 IS 1328: 1996 VENEERED DECORATIVE Rs.5OOOI- FOr Physical PLYWOOD

33 IS 1395: 1982 LOW AND MEDIUM ALLOY RS.21oool· for grade E41RX, E·41 BX: Included w.eJ. STEEL COVERED ELECTRODES Rs.230001· lor grade E49CX, E55X, 07.02.2017 E63X,E49RX,E55RX,E63RX,E49X. Rs,2800OJ- for grade E66BX,E76BX,E83BX; For chemical RI). 400OJ~

34 IS 1475(Part 1): 2001 Self-contained drinking waler Rs.15OO0/- Up to 200 liters coolers

35 IS 1489(Part 1): 2015 PPC· FLY ASH BASED Rs,11000/· [Rs,lOOO/·lor Physical, RsAOOO/- tor Chemical)

36 IS 1489(Part 2): 2015 PPC CALCINED CLAY BASED Rs.l1oo01. [ Rs,7oool·for Physical, Rs.4000/· for Chemical]

37 IS 1554(Part 1): 1988 PVC INSULATED (HD) CABLES Rs.20000/- for non-mining single core For Cal.gory 01 only UPTO 1100V cable & Rs,2000 for each extra cora. Rs.22500 tor mining single core cable & Rs.2000 for each extra core

"­ Page 2 14-Mar·17 ""~ IS Number Product Testing Charge Remark . .._-_.. __ -.-.--.~..---..---..~-~..---.-­ 38 IS 1659; 2004 BLOCK BOARDS Rs.11000t- For Physical

39 IS 1709: 1984 CAPACITORS FOR ELECTRIC Rs.200001­ FAN MOTORS

40 IS 1786 : 2008 COLD-TWISTED STEEL BARS I) Siz. B-12mm: Rs.80001· All t.sl + FOR CONCRETE RS.100001· (or Pullout Test [For REINFORCEMENT phyolcal: Rs.60001· +Rs.10000 for pullout test; For chemical: Rs.2000H;

ii) Size 16-28mm. Rs.9000/· Ailiesl + Rs.150001- for Pullout Test [For physical: Rs,7000/- +Rs.15000 for pullout lest; For chemical: Rs.20001·):

iii) Size 32mm: Rs.10000/- All test + Rs.15000/- fOr Pullout Test [For physical: Rs.800OJ· +Rs.15000 for pullout test; For chemical: Rs.2000/­ (Rs.4000/- wIth micro element)

41 IS 1978: 1982 LINE PIPE Rs. 100001· [Rs.75001·for Physical, Rs.2500/- for Chemical]

42 IS 2046 : 1995 DECORATIVE THERMOSETTING Rs.2OOOOI· [ Rs.16000I·for Physical, SYNTHETIC RESIN BONDED RoAOOO/- for Chemical] LAMINATED SHEETS

43 IS 2062: 2011 Hot Rolled low, medium and high RS.105001· [Rs.8OOOI.for Physical, tensile structural steel Rs.2500/- for Chemical]

./ 44 IS 2074 : 1992 READY MIXED PAINT AIR Rs,800OJ~ for chemica! DRYING, RED OXIDE-ZINC CHROME, PRIMING

45 IS 2062: 1993 STATIONARY STORAGE TYPE Rs.15ooo Included w.eJ. ELECTRIC WATER HEATERS 07.02.2017

46 IS 2202(Part 1): 1999 FLUSH DOORS SHUTTERS Rs.180001~ For Phys!cal (PLYWOOD FACE PANELS)

47 IS 2312 : 1967 PROPELLER TYPE AC Rs.50001- for 1 fan, 15000/- for 3 fans Up to' 600mm sweep VENTILATING FANS

48 IS 2645 : 2003 INTEGRAL WATER-PROOFING RS.90001· [ RS.8000/·for Physical, COMPOUNDS FOR CEMENT Rs, 1000/~ for Chemical] MORTAR AND CONCRETE

49 IS 2830: 2012 CARBON STEEL BILLETS Rs.95001·1 RS.55001·for Physical, (STANDARD QUALITY) RsAOOOI- for Chemicall

50 IS 2993 : 1998 MOTOR CAPACITORS Ro.22000 up 10 5 MFD; Ro. 30000 for 6-10 MFD: Rs.33000 for 11·20 MFD: Rs.38000 for 21-33 MFD; Rs.45000 fOr 3442 MFD.

51 IS 3087 : 2005 PARTICLE BOARDS OF WOOD Rs170001-, Included w,e." AND OTHER LlNGNO For physical Rs.13500l-, 07.02.2017 CELLULOSIC MATERIAL: For chemical Rs.3500/~ (MEDIUM DENSITY) FOR GENERAL PURPOSES

52 IS 3097 : 2008 VANEERED PARTICLE BOARD Rs.150001· [ Rs.110001·for Phyoical, Rs,4000/· for Chemica!]

53 IS 3812(Part 1): 2013 Pulverized Fuel Ash ~ Part 1 : for R$.13500/- [ RS.95001·for Physical. use as pozzolana in Cement, RsAOOOl· for Chemlcall Cement Mortar and Concrete

54 IS 3812(Part 2): 2013 Pulveriz:ed Fuel Ash - Specification Rs.70001-( RS.3OOO/·for Physical, Included w.eJ. for use as Admixture in Cement Rs.40001~ for Chemical] 07.02.2017 Mortar and Concrete

55 IS 3854 : 1997 SWITCHES FOR DOMESTIC & Rs.7000 for6·10A,2401250V: Up 10 32A SIMILAR PURPOSES Rs.1 0000 for 16A,2401250V: Rs.11000 for 20A,2401250V: Rs.12000 for 25A,2401250V; Rs.15000 for 32A, 2401250.

56 IS 4283: 1981 HOT AIR FANS Rs.10000 Included w.e.f. 07.02.2017 ~ Page 3 14·Mar~17 IS Number Product Testing Charge Remark

57 IS 4984: 1995 H.D. POLYETHYLENE PIPES Rs.12iJOO/· [ RS.100001·lor Physical, Included w.eJ. FOR POTABLE WATER R•.2iJOO/· for Chemical} 07.02.2017 SUPPLlES,SEWAGE AND INDUSTRIAL EFFLUENTS

58 IS 4985 : 2000 UNPLASTICISED PVC PIPES Rs.160001· [ RS.140001·for Physical, Induded w.e.f. FOR POTABLE WATER Rs.2000J~ for Chemica!] 07.02.2017 SUPPLIES

59 IS 4990: 2011 PLYWOOD FOR CONCRETE Rs.21000/· [ R'.17000/·for Physical, SHUTTERING WORK RS.40001· for Chemicall

60 IS 5206 : 1983 COVERED ELECTRODES FOR RS.200001· [Rs.165001·lor Physical, MANUAL ARC WELDING FOR Rs.35001· for Chamica~ STAINLESS STEEL AND OTHER HIGH ALLOY STEEL

61 IS 5405 : 1980 SANrrARY NAPKINS Rs.60001-( R'.5000/·for Physical, Included w.e.f. Rs.1000/· lor Chemicall 07.02.2017

62 IS 5410: 2013 CEMENT PAINtr COLOUR AS RS.l00001- for Chemical REQUIRED

63 IS6419: 1996 WELDING RODS AND BARE RS.200001· [ Rs.150001-for Physical, Include

64 IS 8042: 2015 WHITE PORTLAND CEMENT RS.12000/· [R•.6500/·for Physical. R5.55001· for Chemical)

65 IS 8976 : 1992 ELECTRIC INSTANTANEOUS .~ Rs.1S000 (Inclusive of safely testing WATER HEATERS Charges as per IS 302·2·35@ Rs.5000I·)

66 IS 10322(Part SlSec 1): FIXED GENERALPURPOSE Rs.120001· 2012 LUMINIARES

67 IS 10322(Part SlSoo 2): RECESSED LUMINIRES Rs.12ooOl· 2012

68 IS 10322(Part SlSec 3): LUMINAIRE FOR ROAD AND R'.15OOO/· 2012 STREET LIGHTING

69 IS 10322(Part SlSee 4): LUMINARIES·PORTABLE Rs.15OOO 1987 GNERAAL PURPOSE

70 IS 10322(Part 51Sec 5): FLOOD LIGHTS RS.180001· For Optical distance 2013 upto 24 meter

71 IS 12330 : 1988 SULPHATE RESISTANT RS.50001- for Chemical PORTLAND CEMENT

72 IS 12406 : 2003 MEDIUM DENSITY FIBRE Rs.12000/- for Physical BOARDS FOR GENERAL PURPOSES

73 IS 12823: 2015 PRELAMINATED PARTICLE Rs.1BOOO/- for PhYSical BOARD

74 IS 13801 : 2013 CHEQUERED CEMENT Rs.70001· for Physical CONCERETE TILES

75 IS 14255 : 1995 Aerial Bunched cable for working RS.200001­ voltagess upto and including 1100 Volts, Specification.

76 IS 14333: 1998 HDPE PIPE FOR SEWERAGE RS.12oool· Included w.e.f. 07.02.2017

77 IS 14587 : 1998 PRELAMINATED MEDIUM Rs.16000/- for PhySical DENSITY FIBRE BOARD

78 IS 15652 : 2006 Insulating mats for electrical RS.20000 purposes

79 IS 15658: 2006 Precast Concrete blocks for Rs.120001·[Rs.340001· Extra for Included w.eJ. paving ~ Specification optional tests) 07.02.2017

14·M3r-17 IS Number Product Testing Charge Remark

80 IS 80898(Part 1): 2002 IS/lEG 80898(Pl-1 ):2002 ­ Upto 32A-Rs.300000 for single pole, Up 10 125A Electrical Accessories - Cireuit Rs.350000 for double pole, breakers for overcurrenl protection Rs.400000 tor three pole, for household and similar Rs,450000 for foor pole installation : Part~1 Circuit-breakerS for AC operation Upto 63A-Rs.350000 for single pole, RsAOOOOO fOf double pole, RsA5000Q for three pole. Rs.500000 for four pole

Upto 125A-Rs.530000 fo( single pole, Rs.580000 for double pote, Rs.680000 for three pole, Rs.110000 for four pole.

Page 5 14-Mar-17 OTHER SPECIALIZED TESTING FACILITIES CHEMICAL DISCIPLINE

PRODUCT MATERIAL OF TESTI REMARKS NAME OF TEST CAUBRATION LABORATORY FACIUTIES

Cement mortar, Cement ASTM C-85-75 Lime content, CHEMICAL concrete, Cement plaster & Silica contents. Inaredients CHEMICAL • Pig Iron Silicon, I 5 :1493(1)-81, 15 : 13502-92, Manganese, 15: 2842 -80 Sulphur, Phosphorus CHEMICAL Trace metal in surface, ground Mercury, IS: 3957-1966; IS: 1070­ water Cadmium, 1992 Selenium, Lead, Arsenic, Aluminum CHEMICAL . Pesticides All relevant Tests

Aluminium Phosphide Tab, IS: 6438,

Copper Oxychloride IS:1486,

Chloropyriphos IS: 8944

Dichlorovos IS: 5277

Dimethioate EC IS:3902, 3903

Phorate G Encapsulated IS: 9359

Carbufaran G Encapsulated IS:9360

CHEMICAl­ Ferro- Molybdenum, Carbon, IS :1559-1982, IS :1469­ Molybdenum, 1993 Silicon, Sulphur, Phosphorous, Copper, Aluminium CHEMICAL Zinc Aluminium, Zinc, IS :209-1992 Lead, Cadmium, Iron, Tin, Copper, Thallium,

, CHEMICAL Effluent water, Sewage water, i BOD,COD,TDS,H • IS: 3025 wastewater eavy metal, TSS, i ! pH

i , MICROBIOLOGY Effluent water, Sewage water, i Total coliform, 15:1622:1981 wastewater i Faecal coliform , PAINT Distemper Dry/Oil Emulsion Resistance to dry IS :4272-1965 rubbing, IS :428-1969 Recoating properti es, Drying time, Consistency, Finish, Colour, Fastness ! i to light, , ' Residue on sieve, ! , Wet opacity, Behaviour I towards lime , PAINT Ready mix Road marking paint All tests 15:164:1981

!

,PAINT 1. Thermoplastic road As per clause MORTH Specification i marking paint 803.4 2. Glass beads , i, PAINT PU PAINT As per different M&C/PCN/100/2009, ROSO M&C/PCN/110/2006,

Specification M&C/PCN/101 12007, i M&C/PCN/102/2009 etc. PAINT Cement Paint Water repellence IS :5410·1992 test, Recoating properties, i Drying time, Composition, Finish, Colour, Fastness to light, Residue on sieve, Resistance to dry rubbing, Composition CIVIL ENGG.DISCIPLINE

PRODUCT MATERIAL OF TEST I CALIBRATION REMARKS NAME OF LABORATORV TEST FACILITIES · CIVILENGG C!!rJ1ent Concrete Mix design 15: 10262 i CIVILENGG Pre Cast Concrete Pipes. 15:458 CIVILENGG A.C. Pressure Pipes. 15:1592(On site) ·• CIVILENGG 5alt Glazed 5tone Ware Pipe 15:651((On site)) CIVILENGG DBM/BM/5DBC/AC MORTH Grading. (5eparate raw . aggregate are ! i required) Density Binder Contents CIVILENGG Autoclaved aerated blocks 15:2185par!(3) , CIVILENGG Lime 15:712

CIVILENGG Non Destructive tests on 15:13311(Rebound ! concrete hammer & UPV) ((On site)) CIVILENGG Granite 15:14223 , CIVILENGG Marble 15:1130 CIVILENGG 5tones 15:1121,15:1122, 15:1123, 15:1124 · CIVILENGG Gypsum board 15:2095 • CIVILENGG Mineral 15:8183 I CIVILENGG Cement Capsules DGMS CIVILENGG Resin Capsules DGM5 CIVILENGG Admixture 15:9103 CIVILENGG Concrete Beam IS:456/15:516 (Flexural Strength) CIVILENGG 5urkhi IS:3182 CIVILENGG Concrete Cable Cover IS:5820 CIVILENGG GFR Plastic Door 5hutter IS:14856 CIVILENGG RC~PIPE upto 900 mm dia 15:458 MECHANICAL DISCIPLINE

PRODUCT MA TERIAL OF TEST I NAME OF REMARKS TEST CALIBRA TION LABORATORY FACILITIES MECHANICAL GREY IRON CASTING 15:210-2009 MECHANICAL MILD STEEL WIRE FOR 15:280-2006 GENERAL ENGG. PURPOSES MECHANICAL WROUGHT ALUMINIUM 15:737-2008 AND ALUMINIUM ALLOY SHEET AND STRIP MECHANICAL COPPER CAST ALLOY 15:781-1984 SCREW DOWN BIB TAPS & STOP VALVES MECHANICAL CENTRIFUGALLY CAST 15:1536-2001 SPUN IRON PRESSURE PIPES MECHANICAL PLAIN HARD DRAWN 15:1785-1983 STEEL WIRE FOR PRESTRESSED CONCRETE MECHANICAL LOW TENSILE 15:1977-1996 STRUCTURSL STEEL MECHANICAL HOUSEHOLD SEWING 15:1610-2000 MACHINES MECHANICAL INDENTED WIRE FOR 15:6003-2010 PRESTRESSED CONCRETE MECHANICAL UNCOATED STRESS 15:6006-1983 RELEIVED STRAND FOR PRESTRESSED CONCRETE MECHANICAL STAINLESS STEEL PLATE, 15:6911-1992 SHEET AND STRIP ELECTRICAL DISCIPLINE

PRODUCT MATERIAL OF ! NAME OF • TESTI REMARKS TEST CALIBRA TION LABORATORY I . FACILITIES ELECTRICAL Self contained drinking Water Insulation resistance IS :1475-1978 with Cooler · test.High voltage test. Amendments upto 200 liters i Cooling capacity , rating test. Maximum operating condition test. Storage capacity , test ELECTRICAL Luminaires 40W • Visual examination. IS : 10322(1 to V) I ELECTRICAL FTL.80W Mechanical strenqth IS : 10322(1 to V) · ELECTRICAL HPMV.120 Thermal Endurance IS: 10322(1 to V) I test ELECTRICAL HPMV.70W Resistance to heat. IS: 10322(1 to V} · 'Insulation ELECTRICAL HPSV, 150W ,250W, Resistance test & IS : 10322(1 to V) HPSV Electric strength, Rain Proof test, Dust ! Proof test, Wind i force i , lest • Ballasts for Fluorescent IS :1534(1) ELECTRICAL All tests • Lamos 140W) ELECTRICAL Wiring accessories (6/16 All tests IS :1293-1988, IS :1258­ Amps.) 1987, IS :3854­ 1997 • ELECTRICAL Propellor type AC. Ventilating All tests ' IS :2312-1967

Fans (upto 600 I • mm.sweeo) , , ELECTRICAL Enamelled wire (All size) All tests IS :13730 ELECTRICAL Carries and bases for • All tests IS :2086-1993 rewirable type electric fuses (upto 100 A) iLECTRICAL Cable Testing • All Tests IS :10810 (I to VII. X to XV. XXXVII, XXXVIII. XXXXII, XXXXIII, • XXXXV i ELECTRICAL , Transformers C.T, PT., 1. IS: 2026 , Insulators, Lightening/Switching i IS: 2705 I Cables Etc Impulse Voltage IS: 3156 with Stand test up to 1000KV , 2. AC power frequency voltage with stand I test UP to 550 KV i ELECTRICAL Power & Distribution Lightning Impulse ------­

i Transformers Test upto 1400KV & Temperature Rise as per IS 2026 i i ELECTRICAL PVC Insulated Cable IS 694: 1990 Amdt 1 ­ PVC Insulated (Heavy Duty) 4 Reaffirmed 2005, Electrical Cable Cross Linked IS 1554( pt-I)1988, Polyethylene PVC Amdt 4, Reaffirmed i Sheeted Cable Aerial 2005 IS 7098( Pt-I) Bunched Cable Amdt 3, Reaffirmed ! 2005& IS-14255: i i 1995 Reaffirmed i 2005 i

ELECTRICAL Electric Ceiling Fan & IS 374: 1979 Amdt ! Regulator 1 to 6 ELECTRICAL Propeller type AC Ventilating IS 2312 : 1967 Fan Amdt 8 Reaffirmed (Upto 600mm, Sweep) 2005 ELECTRICAL Road and Street Lighting IS: 10322 ( Part 5 luminaries Sec 1) .1985 Arndt 2 for Florescent, Incandescent Reaffirmed 2005 ,GlS, High IntenSity Discharge (HID) Sodium Vapour and Metal Halide lamps, ! , General Purpose ELECTRICAL Portable General Purpose IS : 10322{ Part 5 luminaries Sec 2), 1985 Arndt 2 for Florescent, Incandescent Reaffinmed 2005 ,GlS, High IntenSity Discharge (HID) Sodium Vapour and Metal Halide Lamps I ELECTRICAL Road and Street lighting IS : 10322{ Part 5 luminaries Sec 3) ,1987 Amdt 3 for Florescent, Incandescent Reaffinmed 2005 i i ,GlS, High IntenSity Discharge (HID) Sodium Vapour and Melal Halide i I Lamps ELECTRICAL Portable General Purpose IS : 10322( Part 5 luminaries Sec 4) ,1987 Arndt 1 for Florescent , Incandescent Reaffinmed 2005 i ,GlS, High IntenSity Discharge (HID) Sodium Vapour and Metal Halide i Lamps i ELECTRICAL Flood Light Luminaries for IS : 10322( Part 5 Florescent, Sec 5) ,1987 Amdt 1 Incandescent ,GLS, High Reaffirmed 2005 Intensity Discharge ( HID) Sodium Vapour and Metal Halide Lamps (For Optical Distance upto 24 Mtrs) ELECTRICAL AC Motor Capacitor IS 2993-1998 i Reaffirmed 2006 ELECTRICAL Capacitor for Electric Fan IS 1709-1984 Admt i Motor 1&2 i ELECTRICAL Ceiling Rose IS 371-1999 Admt 3 ELECTRICAL Plugs & Socket Outlet 6A, IS: 1293-2005 Admt 16A 1 to 4 ELECTRICAL Domestic Switches Up to 32 IS: 3854 1997 Admt A 1 to 5 ELECTRICAL .Ballast for Fluorescent IS 1534( Pt 1)­ Lamps 1977 5 reaffirmed 2001 ELECTRICAL Ballast for High Pressure IS 6616 (PI 1)1982 Mercury & Adms 1 reaffirmed ! Sodium Vapour 2001 ELECTRICAL Self Contained drinking water IS 1475 Pt 1 -2007 Cooler (up to 200 Ilrs) ELECTRICAL Enameled Wire IS 13730Sec-11993 • Amds 1reaffirmed 2003 ELECTRICAL Capacitor for fluorescent ( IS 1569-1976 ) lamp Adms 1 reaffirmed 2001 ELECTRICAL Hot air fan IS 4283-1981 Amds 3 Reaff2003 ELECTRICAL Insulating mats for Electrical I.S 15652:2006& IS purposes 2584: 1963 ELECTRICAL Basic Environmental Testing IS: 9000 (Part­ procedures for Electronics 2/Sec-1-4), 1977 and electrical Items Cold Test: ELECTRICAL Basic Environmental Testing IS: 9000 (Part­ procedures for Electronics and 4ISec-1-2), 1977. electrical Items Damp Heat Test. ELECTRICAL Basic Environmental Testing IS: 9000 (Part­ procedures for Electronics and 3/Sec-1 to 5), 1977. electrical Items Dry Heat Test

I ELECTRICAL De9ree of protection of IS 12063: 1987 electrical & reaff 2004 electronics enclosure IP : First Character 1 to 6 IP : Second Character 1 to 8 ELECTRICAL Noise Measurement of DG ISO 3744:1994(E) SET Gazelle Notification No. G.S.R 215( E) dated 15 Mar 2011 ELECTRICAL Electric Instantaneous Eater IS 8978:1992 Amds ------­ Heater 2 reaff 1989 ELECTRICAL Electronics Ballast for Tubular IS 13021( Ptl & II ) ------­ Fluorescent Lamps :1991 RUBBER, PLASTIC. PAPER &TEXTILE

PRODUCT MATERIAL OF TEST TEST I CAUBRATlON REMARKS NAME OF LABORATORY FACILITIES RPT Common Proofed All tests 15:11630/1991 CanvaslJutel . 15:2089/3344/2789/790 (Tarpaulin) 3 RPT Rope -Manila, , All tests IS: 1084, 2452, 4572, i , , 8674,5175,12733 PP. HOPE RPT Cotton Drllll Canvasl All tests IS: 177/1422 Duke Fabric RPT Cotton Sheets, Bag All tests IS: 180, IS: 2566, 2580, 7406 RPT Hand cotton gauge All tests IS:758 RPT Cotton Umbrella cloth All tests IS: 2457 RPT Woolen Blankets and All tests IS: 892, 3783, 1681, dress materials 679 RPT Plastic Moulded Briefcase All tests IS: 9848 RPT Plastic film and sheet All tests IS: 2076, 6307, 12866, 7290 2508 RPT Bed Sheet All tests IS: 745, 175 RPT Brushes Paint & Vamish, All tests IS: 384,487 Flat & oval RPT Handloom Cotton, All tests IS: 854, 3771 Turkish, Honey comb, Huckaback Towel & Towelling Cloth RPT Handloom Wool Blanket All tests IS:894,892 I RPT Cotton Mosquito Netting All tests IS: 1143 ! RPT Cotton Cellular Shirting All tests IS: 1144 RPT Vinyl Coated Fabric All tests IS: 1259 RPT Handloom Cotton Durries All tests IS: 1450 RPT Socks, Woolf All tests IS: 2187,3329,5084 Cotton/Nylon RPT Vest, Wool/Cotton All tests IS: 3330, 4964 I

RPT Unbacked flexible PVC All tests IS: 3462, 3464 flooring RPT HOPE· Bucket All tests IS: 3730 RPT Dosuti Cotton All tests IS: 3770 IRPT I Knitted puttees dyed I All tests IS- 4053 I !RPT · Rubber Sealing ring All tests IS: 5382 [RPT' Sanitary Napkin · All tests IS: 5405 L_~RPT Cork Composition Sheet All tests IS: 4253 RPT Jute Bag & Gunny Bag I All tests IS: 1943,9113,2566 i RPT Insulating Mat All tests IS: 15652 RPT Balaclava Cap All tests IS: 2783 Disposable Artificial All tests IS: 7180 ~PT Insemination .------­ Gloves I I RPT Tarpauline made from All tests IS: 7903 I HOPE , I­ I RPT Textile Angola Shirting All tests IS: 8331 -~----~-- I blend sullingl ' All tests IS: 11248,11814, , RPT ! I ShlrtinQ/Saree I 11815 , RPT PVC Water stop i All tests IS: 12200, 15058 ! Testing of Paper/MICR · All tests IS: 1060 (pt-1), 1848, Cheque paper 14490,4658,695611087 ~:.: ~- IVacuum flask All tests IS: 7708, 3702

PVC Conduit Pipe All tests IS: 9537 i IFittings for rigid non· I All Tests IS :3419 l;:~~_~ metallic conduits I RPT IHOPE Wash Bowl IAll tests IS: 5322 Rubber Hand Gloves All tests IS: 4770 RPT . --, I RPT · Tooth Brush All tests IS: 3387 RPT Hospital Rubber Sheet All tests IS: 4135 RPT Bitumen Polymeric water · All tests IS: 13826,7193, 1322 i proofing I membrane ---~-- RPT i Rubber washer for water All tests IS: 937 , Ifitting for Fire fiQhtinQ purpose I RPT · UPVC Pipe All tests IS: 4985 RPT CPVC Pipes All tests IS:15778 RPT HOPE Pipes All tests IS :4984, IS:14333 RPT · Cycle Rubber Tube All Tests IS:2415 ~~.-. • RPT Polypropylene random All Tests IS:15801 L_~~~~ copolymer pipe I • NOT &METALLOGRAPHY

PRODUCT MATERIAL TESTI REMARKS NAME OF LABORATORY OF TEST CALIBRATION FACILITIES NOT & MSI SSI Low alloy I MIG All tests including 18: 814/18: 1397118:5206 Metallography Welding Electrodes Radiography, I A8MEI AW8 Diffusible Hydrogen specifications etc. test (Mercury method), Metal Recovery tests etc NOT & Welding and approval of All tests including 18: 8221816/7310 Metallography welding procedures Transverse tensile, IA8MEI EN specifications Root & Face bend test, etc. Side Bend test, Charpy impact test at -50 deg. C to ambient temperature. NOT & Certification of welders All tests IBR-1950 liS: 7310 liS: Metallography 73181 ASME lAWS! ENSpecifications etc. NDT& Welds, castings, Radiographic testing 18:1182/18: 2595/18: Metallography Forgings, pipes/tubes 48531 A8TMI A8MEI EN Specifications etc. NDT& Radiographs of welds, Interpretation 18 : 7810 IA8TM/A8MEI Metallography casting all types EN specifications NOT & Welds I metals I products Magnetic particle I 18: 3703118: 3658 IA8TMI Metallography Liquid Penetrant EN specifications Testing NOT & Metallic products! weldsl Ultrasonic testing IS: 422511S: 4260/1S: 87911 Metallography Castings IS: 766611S: 639411S: 154351 A8TMI A8ME I AWSI EN

specifications etc. I NOT & Metal products Metallographic tests 18: 7318/11371/77391 i Metallography including 12037/28301 A8TM etc. Microstructure , coating test, case depth, grain size, inclusion rating, sulphur print etc.

•••••••••••