Why grounding is critical to data center

You can gain a competitive edge with your Data centers need to customers by understanding and then offering achieve unprecedented levels of uptime to keep pace with network grounding/bonding expertise. modern business demands To achieve these uptime goals, data Network grounding system in a data center center managers are paying in- creased attention to facility in- frastructure issues, including Telecommunications the network grounding system. grounding busbar If you’re a contractor, un- derstanding network ground- ing can give you a competitive Equipment to edge by advising your custom- rack jumper ers on how to improve network availability. Proper grounding of data cen- ter equipment, often called - AC electrical panel work grounding or the data center grounding infrastructure, is defined by TIA/EIA-942 Tele- Paint piercing communications Infrastructure hardware Standard for Data Centers, and goes beyond the requirements of the National Electrical Code (NEC) to protect equipment and improve system reliability. Common bonding network to rack jumper

Grounding by tier Source: Panduit TIA-942 has adopted the tier definition provided by the This image of a TIA-942-compliant data center network grounding Uptime Institute (www.upsite.com). Tier I is the lowest system includes the AC electrical panel, must be bonded by level, which allows 28.8 hours of site-caused0605cidef1 informa- an electrician. The electrician typically installs a busbar network, tion technology downtime per year. By contrast, Tier IV including the telecommunications grounding busbar. Other data centers used within financial institutions, Web elements include the equipment-to-rack jumper, paint-piercing hosting organizations, healthcare and others with the hardware, and the common bonding network-to-rack jumper. greatest need for critical uptime, have availability rates of 99.995%. This requires the data center be designed to than 5 seconds per day (Industry Standard Tier Classifica- experience only 0.4 hours of downtime annually— tions Define Site Infrastructure Performance, authored by . Pitt Turner IV, John H. Seader, and Kenneth G. Brill TOM TURNER is business development manager Panduit Corp. and available at: www.upsite.com/file_downloads/PDF/ (www.panduit.com). Tier_Classifications.pdf). Building data centers to meet Reprinted with revisions to , from the May 2006 edition of CABLING INSTALLATION & MAINTENANCE Copyright 2006 by PennWell Corporation tier requirements is a complex , encompassing expertise additional damaged equipment. in a wide range of technical specialties, including architecture, 5. All metallic components in the data center shall be bonded cabling infrastructure, electrical design, environmental con- to the grounding system. The goal is to have all conductive ma- trol, and fire protection. To this task manageable, terials at the same electrical potential to minimize current flow. TIA-942 provides design guidelines to meet the uptime re- Current flows when there is a difference in potential between quirements of each tier level. components. If the current flows across a piece of equipment, For example, when designing a Tier I data center, TIA-942 states, “A data center Kits engineered for network grounding grounding infrastructure is not required, but Grounding jumper may be desirable as an economic method to Paint piercing Grounding strips hardware satisfy equipment manufacturers’ grounding for requirements.” At Tiers III and IV, the data mounting rails center infrastructure grounding system is ab- solutely required. Contractors are ideally positioned to pro- vide much of the network grounding system, and those understand these require- ments can provide a value-added service— the expertise to help customers understand and implement the necessary grounding - tem to improve their data center.

Network grounding design NEBS Level 3 The two goals of the grounding system are to Grounding busbar compression lugs equalize electrical potentials and to create a low resistance to ground. Five basic principles are used when damage may occur. Equip- Kits made specifically forSour ce:network Panduit designing a grounding system to accomplish these goals: ment, racks, cabinets, lad- grounding include: grounding 1. The grounding system shall be intentional. Careful plan- der racks, enclosures, and jumpers, NEBS Level 3 compres- ning must be given to network grounding, just like any other cable trays must be bond- sion lugs, paint-piercing hard- system deployed in the data center. As the grounding system to the grounding system. ware, grounding strips for cabinet 0605cidef2 is no more reliable than its weakest , only high-quality (Additional information is mounting rails, and grounding components can be used and trained professionals must make available in the white paper, busbars. all connections. Facility Considerations for 2. The grounding system shall be visually verifiable.When im- the Data Center, authored by American Power Conversion, plemented properly, you should be able to visually inspect ev- Cisco Systems, and Panduit Corp.) ery component of the grounding system, from the equipment, The grounding section of TIA-942 offers guidelines that to the rack, to the common bonding network (CBN), to the meet the basic principles and adds additional details specific earth. Such a system can be inspected for degradation and is to the modern data center environment. One important issue accessible during moves, adds, and changes (MACs), ensur- is the creation of electrical continuity throughout racks and ing long-term system reliability and scalability. cabinets. Because racks and cabinets are made of paint- 3. The grounding system shall be adequately sized. TIA-942 ed components that are bolted together, there is no guaran- provides guidelines for each component of the grounding sys- tee that electrical continuity exists from one rack component tem. Improper use of the guidelines can reduce network avail- to the next. In the data center, rack and cabinet continuity ability and cause premature equipment failure that contributes is important for safety; electrostatic discharge (ESD) protec- to increased operating costs. tion; and the proper grounding of switches, servers, and power 4. The grounding system shall direct damaging currents away strips. Continuity may not exist if the installer fails to scrape from equipment. A grounding system that complies with paint between sections of rack or use specially designed paint- TIA-942 requires each rack to bond directly to the CBN, there- piercing hardware. by directing current away from sensitive electronics. For in- stance, a common error is to daisy-chain racks together. Network grounding installation During a surge event, the entire row of daisy-chained racks A licensed electrician is required to bond the AC power pan- becomes energized with stray current, potentially resulting in el. Additionally, the electrician typically installs the busbar network throughout the building. The communications • Hardware, such as thread-forming screws and paint-pierc- installer can complete the grounding of the busbar to the ing washers, and studs that through the durable finish- equipment. Often, electricians are hired to build the grid of es that coat data center racks and cabinets, thereby creating CBN conductors under the raised access floor. Even in this a metal-to-metal connection (bond); case, little thought is given to how the grounding network • Components, such as hardware and jumper cables, that bonds to the equipment. are tested for their ability to create electrical bonds and Alarmingly, numerous data centers in operation today have carry current. grounding busbars in place, and a grid of CBN conductors un- Additionally, the kitted system should comply with TIA-942 der a raised floor, but not a single rack or cabinet bonded to and fit any rack or cabinet that complies with the EIA-310D the CBN. It is that the data center owner intended to have standard. Everything necessary to provide a TIA-942-compli- grounding; however, if the racks and cabinets are not bond- ant installation should be included in the kit, such as grounding ed to the grounding system, then there is no protection. Cre- strips, busbars, and jumpers for creating electrical continuity ating electrical continuity within racks and cabinets is best throughout a rack or cabinet; antioxidant to guarantee the accomplished during initial installation. This is also the best long-term reliability of the electrical bonds; and instructions to create the bond from the rack to the CBN before it is that describe the proper installation techniques (helps simpli- forgotten. Equipment that is installed on the racks should be fy ordering of grounding components and minimizes the risk bonded at this time. of overlooking details). It makes sense that the contractor who installs racks, cabi- Each component and connection in the system is critical nets, and equipment is in the best position to create the parts to creating a low-impedance grounding path. In addition to of the grounding system that go along with the installation. using components that are listed by a nationally recognized Collectively, this lets you be better positioned with customers testing laboratory, such as Underwriters Laboratories (UL), by providing valuable information that educates data center the jumper assemblies within the kits should also be listed to decision-makers on how to protect their investment. UL 467 Grounding and Bonding Equipment as a means of fur- You should include a separate line item in bid submittals for ther certifying their applicability to grounding. upgrading to a TIA-942-compliant grounding system, even if Ideally, components that make up the grounding kits are the data center has not requested such an upgrade. This inclu- tested to determine their ability to function during real- sion lets you make a competitive bid, to engage the customer world conditions, such as earthquakes, lightning strikes, and in a conversation about TIA-942 grounding, and ultimately AC power faults. Telcordia Technologies’ NEBS Level 3 to create some distance from your competition. of power connectors simulates response to these events and other scenarios that are likely in the data center environment. Common problems and solutions (For more information, see The Electrical Distributor, January Data centers often run into trouble with their grounding sys- 2004, “Minimize Service Interruptions.” www.tedmag.com). tems when any of the following mistakes are made: NEBS Level 3 is the most stringent test available to the indus- • Using the wrong of grounding connectors. For exam- try, and power connectors that meet NEBS Level 3 should be ple, connectors that use setscrews to fasten the conductor specified for data centers at every tier level. can loosen over time, degrading the electrical bond. • Applying hardware, such as screws and washers, that are Business booster not designed to make an electrical bond, resulting in un- Network grounding provides a win-win opportunity for you, grounded equipment. and for data center managers. If you, as a contractor, under- • Failing to create an electrical bond between the structural stand the value of a well-designed system, you can provide - components of racks and cabinets can trap currents within pert consultative services and enhance your positioning as a sections of them, resulting in potential safety hazards, fail- valuable partner. ure of ESD protection, and ungrounded equipment. To avoid the problems that are common in network ground- A kitted grounding system can help installers avoid the mis- ing systems, you should implement only engineered solutions takes that plague data centers. Key features of a good ground- that comply with accepted industry standards, such as TIA-942 ing system should include: and NEBS Level 3. And following proper network grounding • Permanent copper compression lugs that do not loosen practices will provide your customers with the highest level over time; of network grounding capability.