<<

12345 College Blvd. Over land Park, KS 66210-1299 Sean Bergman, Email: [email protected] 913-469-2535 (Office) 913-469-2566 (Fax) Tripp McMillan, Master Email: [email protected] 913-469-8500, ext. 3995 LIGHTING SPECIFICATIONS – POLSKY

CONTROL FRONT OF HOUSE POSITIONS LIGHTING INVENTORY SCHEDULE  Lightboards: The Front of House positions are located on a following the ETC Ion or ETC Expression 3 Unit Type Quantity  400 Channels lines of the stage thrust as well as 24×10 Submasters, soft patch a tension grid directly over the SOURCE 4 ELLIPSOIDALS stage thrust. 05 degree 11 DIMMERS 10 degree 17  Manufacturer: ETC Sensor CATWALK POSITION 19 degree 70 26 degree 201 Quantity: 408 Contains 51 circuits 36 degree 184 Capacity: 2.4K 50 degree 21 System is circuit per TENSION GRID dimmer Contains 77 circuits SOURCE 4 PARS Par EA w/VN, N, 32  57 circuits are located on tension Houselights are on separate M, W flood lenses grid support junctions system, controlled from booth or  20 circuits are located on a pipe SOURCE 4 MULTIPAR STRIPS SR. at the upstage side of the tension 12 cell, 4 circuit 12 grid A company switch or power PAR 64’S disconnect is located upstage VN, N, M, W lamps 34 right on wall. It is a 600A, 3 ADDITIONAL LIGHTING phase single neutral direct wire. SPECIFICATIONS FRESNELS 6" fresnels 1000w 53 The JCCC Master Electrician or  House will supply Roscolux gel his assignee is required to 8" fresnels 2000w 25 only. Source 4 PARnels 40 connect and disconnect any  All fixtures, circuits, are 3 pin equipment to or from the box. stage plugs. PAR 56  Barndoors are available for all 12 cell, 3 circuit 500w per cell 12 LIGHTING POSITIONS fresnels. ELECTRICS  House maintains an inventory of CYC LIGHTS Great American and Rosco  First Electric-36 circuits ETC Color Source 12 gobos. Ianiro Single Cell – 1000w  Second Electric-45 circuits 16  holders support A size Ianiro Three (3) Cell  Additional electrics can be 7 templates (75 mm image area, 1000w per cell made at spare battens by use Altman Econo 3 Cell 8 outside diameter 100 mm) of drop boxes  Source 4 Iris Units (12) FOLLOWSPOTS  All electrics are on manually Selecon Rua – 1200w MRS 1 operated flylines Phoebus Ultra AcrII 2 IRON Xenon 2000w  Booms: AUTOMATED LUMINARIES Total of 8: 8 at 10' MAC Aura XB 12  Baseplates: 8 at 50 lbs. MAC 250 Kryptons 8  Sidearms: 40 Safer Sidearms Apollo Automated Right Arms 2

Spring 2021 Lighting Specifications Polsky Theatre LIGHTING INVENTORY LINESET SCHEDULE AVAILABILITY LINESET DISTANCE FROM DEDICATED The lighting inventory will be NUMBER PLASTER LINE LINESETS used as is. No relamping will be 1 0' - 7" Torms done unless necessary to replace an expired lamp, and no 2 1' - 3" House Teaser conversions will be made after 3 1' - 11" Main Drape plots are accepted. 4 2' - 7" 1st Electric 5 3' - 11" Although the Midwest Trust Center is a state-of-the-art 6 4' - 7" facility and is extremely well- 7 5' - 3" equipped, there is a finite 8 5' - 11" number of each resource. Resources are booked on a first- 9 6' - 7" come, first-serve basis. MTC 10 7' - 3" Operations will make every effort 11 8' - 5" to have the equipment available and in good working order. 12 9' - 1" However, if equipment is out of 13 9' - 9" service for any reason, MTC 14 10' - 5" Operations will not be responsible for providing 15 11' - 1" replacements. 16 11' - 9" 17 12' - 5" Midstage Traveller Standard lighting plot, ground 18 13' - 1" plan and centerline section scale drawings are available. 19 13' - 9" 20 14' - 5" 21 15' - 1" 22 15' - 9" 23 16' - 11" 24 17' - 7" 25 18' - 3" 26 18' - 11" 27 19' - 7" 28 20' - 3" 2nd Electric 29 20' - 11" 30 21' - 7" 31 22' - 3" 32 22' - 11" 33 23' - 7" 34 24' - 3" 35 25' - 7" 36 26' - 3" 37 27' - 0" 38 27' - 7" 39 28' - 3"

Spring 2021 Lighting Specifications Polsky Theatre