Marine and Cable

• Low Smoke Zero Halogen • Type T/N • Type P • Power/Distribution Cable • Control Cable • Signal & Instrumentation • ICW • Cord • Building Wire • Banding • Tools and Accessories

888.326.5174 • summit.com/marine We’re Partners With the Biggest Names in Marine Electrical

We Serve the Marine, Offshore and Markets Summit Electric Supply stocks a complete product offering for our marine, offshore, and shipbuilding partners. Summit is your one-stop supplier for marine applications in addition to a full range of products for the electrical professional, including distribution equipment, motor control, lamps and lighting, wiring devices, conduit and fittings, wire and cable, tools, automation, datacom and more.

Stay in Touch with Summit! • Sign up to receive information on promotions and events or subscribe to our NewsWire, at www.summit.com/signup • Follow us for updates and news at twitter.com/summit_electric • Check out the latest handy mobile apps for electricians – www.summit.com/mobile • Don’t miss a single catalog! Sign up to make sure you continue to receive updated catalogs at summit.com/catalogs. Marine Division

888.326.5174 • summit.com/marine Table of Contents

Low Smoke Zero Halogen Cord M2X Single Insulated Conductor Cable ...... 3 SJEOOW, 300 Volts...... 36 M2XH Power and Control Cable...... 3 SJOOW, 300 Volts...... 36 M2XCH Power and Control Cable, Shielded...... 4 SOOW, 600 Volts...... 37 FM2XAH Overall Shielded Instrumentation Cable...... 5 SEOOW, 600 Volts...... 39 FM2XAAH, Individual and Overall Shielded Bus Drop Cable...... 39 Instrumentation Cable...... 5 Hook-Up Wire, MTW/TEW or AWM ...... 40 Welding Cable, Single ...... 40 Type T/N Diesel Locomotive, Single Copper Conductor, 2kV...... 40 Power/Distribution Cable (600/1000 Volts) Type G & G-GC Round w/Ground, 2kV...... 42 Unarmored...... 6 Type W Portable Power Cable, 2kV...... 42 Aluminum Armored...... 8 Extension Cord...... 44 Bronze Armored...... 10 Control Cable (600/1000 Volts) Unarmored, Multi-Conductor...... 11 Impervious Continuously Welded (ICW) Aluminum Armored, Multi-Conductor...... 12 ICW Armored Instrumentation Cable, Individual and Overall Shielded, 600 Volts...... 45 Bronze Armored, Multi-Conductor ...... 13 ICW Armored Power and Control Cable, 600 Volts...... 46 Signal & Instrumentation, Pairs (600/1000 Volts) IS/OS , Unarmored, Multi-Conductor..... 15 ICW Armored Power Cable, Unshielded, 2.4kV...... 47 IS/OS Shielded Cable, Aluminum Armored, ICW Armored Power Cable,Unshielded, Multi-Conductor...... 16 5kV 133% / 8kV 100% Insulation Level, Shielded...... 48 IS/OS Shielded Cable, Bronze Armored, ICW Armored Power Cable, Shielded, 15kV...... 48 Multi-Conductor...... 17

Connectors and Terminals Type P Type YA-L One-Hole Lugs...... 49 Power/Distribution Cable Cord Grips and Connectors...... 49 2kV...... 18 XLPO/CP, 600/1000 Volts...... 19 Tools and Accessories Control Cable 600 Volts...... 23 Cutting Pliers...... 50 Signal & Instrumentation, Cable Cutters...... 51 IS/OS Shielding, Pairs and Triads, XLPO/CP, Crimping and Stripping Tools...... 53 300-600/1000 Volts...... 27

Reference Material Banding Low Smoke Zero Halogen Selection Guide...... 54 Banding Tools and Supplies...... 32 Low Smoke Zero Halogen Terminal Selection Guide...... 56 Low Smoke Zero Halogen Gland Selection Guide...... 58 Building Wire Marine Cable Ampacity Guides...... 60 THHN/THWN/THWN-2, Copper Conductor,...... 33 Certifying Bodies...... 64 XHHW/XHHW-2, Copper Conductor...... 33 RHH/RHW/USE, Copper Conductors...... 34 Underground Feeder Cable, Copper Conductors w/Ground...... 35

888.326.5174 • summit.com/marine 1 Selection, Service and Savings.

Summit Electric Supply offers a wide selection of industrial marine products, including wire and cable. Our services include in-house custom cable braiding, sourcing of hard-to-find specialty cable, and reliable shipment throughout the nation and around the world. Calling Summit for your marine wire and cable ensures you will receive the best overall value, saving both time and money. Proven Industry Leader Since 1977, Summit has been a supplier of choice for electrical professionals in the construction, MRO, OEM and industrial marine industries. With domestic and international operations, Summit is ranked as one of the top 25 electrical distributors in the nation, based on sales. Focus on Marine and Offshore Summit’s marine division is dedicated to serving the needs of shipbuilders, shipyards and offshore rigs. Whether your project involves the construction, maintenance or repair of offshore vessels, offshore drilling rigs or inland vessels, you’ll be pleased not only with our product lines, but also with our in-house cable braiding services. Our Inventory Our inventory policies are driven by our customer service commitment. Choose from our broad selection of marine products, including marine electrical distribution equipment and motor control gear, marine cable, marine lighting and navigation lighting. We offer products that meet most national and international certifications, including American Bureau of Shipping, Det Norske Veritas, Lloyd’s Register of Shipping, and U.S. Coast Guard standards. Our People Summit’s commitment to training associates at all levels mean you’ll find knowledgable people who offer fast, accurate technical and application support. Our experienced people understand your needs and can make recommendations that streamline your procurement process. Our Service Summit offers local service with a global reach. Through our Middle East, Latin American and international operations, we supply projects across the country and around the world. Call 888-326-5174 or email [email protected] for technical support or to place an order.

The product and manufacturer names contained in this catalog are property of their respective owners. All rights apply. Every effort has been made to ensure the accuracy of the contents of this catalog. In the case of a suspected error, please contact the Summit service center nearest you. Images in this catalog may be representative of a product category and not necessarily of a specific item. This catalog contains product information for both stock and non-stock items, based on local inventories. Please contact your local Summit service center for pricing and availability. This catalog displays a broad, but not complete, sample of our product offering. For information about products not seen in this catalog, please contact your local Summit service center. Many product categories are available from multiple manufacturers. As such, specifications may vary. For critical specification information, please contact your local Summit service center. Minimum order quantities may apply. Various packing sizes and put-up lengths may be available. Please contact your local Summit service center for details. Summit Electric Supply® Marine Wire and Cable Catalog. (MWC12) © 2012 Summit Electric Supply®, all rights reserved. Low Smoke Zero Halogen Power and Control Cable

M2X Single Insulated Conductor Cable

Application: Used as fixed installation cables in various Construction: Electrolytic stranded annealed copper electromechanical and electronic equipment, including marine conductors, IEC 60228 Class 5 (Class 2 and/or tinned on switchboards. Usable in all conditions in marine environments, request). Low smoke, halogen free. Flame retardant, XLPO such as dry, wet or oily locations. insulation (HF90). Color: black. Double insulation available on request. Specifications: Approved by American Bureau of Shipping, Bureau Veritas Lloyd’s Register of Shipping, GL, Class NK, RINA.

Summit Number Designation Size (mm2) O.D. (in.)

M2X1X0.50 S20 1X0.50 0.080 M2X1X0.75 S18 1X0.75 0.090 M2X1X1.5 S16 1X1.5 0.120 M2X1X2.5 S14 1X2.5 0.130 M2X1X4 S12 1X4 0.160 M2X1X6 S10 1X6 0.200 M2X1X10 S16 1X10 0.220 M2X1X16 S26 1X16 0.260 M2X1X25 S41 1X25 0.340 M2X1X35 S66 1X35 0.390 M2X1X50 S106 1X50 0.460 M2X1X70 S133 1X70 0.540 M2X1X95 S212 1X95 0.600 M2X1X120 S250 1X120 0.680 M2X1X150 S300 1X150 0.760 M2X1X185 S400 1X185 0.870 M2X1X240 S500 1X240 0.980 For Low Smoke Zero Halogen Selection Guide, see pages 54-55. For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60.

M2XH Low Smoke Zero Halogen Power and Control Cable

Application: Used as fixed installation cables in various Construction: Electrolytic stranded annealed copper electromechanical and electronic equipment of marine vehicles. conductor. IEC 60228 Class 5 (Class 2 and/or tinned on Usable in all conditions of a marine environments such as dry, request). Low smoke, halogen free. XLP insulation. Separating wet or oily locations. Rated at 600/1000 volts. foil or halogen free bedding compound available on request. Flame retardant, thermoplastic, polyolefin-based compound Specifications: Approved by American Bureau of Shipping, jacket (HM4 / SHF1) HD 604. Color: gray. Lloyd’s Register of Shipping, Bureau Veritas, GL, Class NK, RINA.

Summit Number Designation Size (mm2) O.D. (in.)

M2XH2x1.5 D3 2X1.5 0.330 M2XH2x2.5 D4 2X2.5 0.370 M2XH2x4 D6 2X4 0.410 M2XH2x6 D10 2X6 0.460 M2XH3x1.5 T3 3X1.5 0.350 M2XH3x2.5 T4 3X2.5 0.390 M2XH3x4 T6 3X4 0.440 M2XH3x6 T10 3X6 0.490 M2XH3x10 T16 3X10 0.570 M2XH3x16 T26 3X16 0.670 M2XH3x25 T41 3X25 0.880 M2XH3x35 T66 3X35 0.980 M2XH3x50 T106 3X50 1.120 M2XH3x70 T133 3X70 1.320 M2XH3x95 T212 3X95 1.480 M2XH3x120 T250 3X120 1.660 For Low Smoke Zero Halogen Selection Guide, see pages 54-55. For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60.

Continued on page 4

888.326.5174 • summit.com/marine 3 Low Smoke Zero Halogen Power and Control Cable, Single Insulated Conductor

M2XH Low Smoke Zero Halogen Power and Control Cable

Continued from page 3

Summit Number Designation Size (mm2) O.D. (in.)

M2XH3x150 T300 3X150 1.830 M2XH3x185 T400 3X185 2.040 M2XH4x1.5 F3 4X1.5 0.390 M2XH4x2.5 F4 4X2.5 0.430 M2XH4x4 F6 4X4 0.490 M2XH4x6 F10 4X6 0.540 M2XH4x10 F16 4X10 0.630 M2XH4x16 F26 4X16 0.730 M2XH4x25 F41 4X25 0.970 M2XH4x35 F66 4X35 1.080 M2XH4x50 F106 4X50 1.260 M2XH4x70 F133 4X70 1.460 M2XH4x95 F212 4X95 1.670 M2XH4x120 F250 4X120 1.850 M2XH4x150 F300 4X150 2.040 M2XH4x185 F400 4X185 2.300 M2XH7x1.5 M73 7X1.5 0.460 M2XH7x2.5 M74 7X2.5 0.510 M2XH10x1.5 M103 10X1.5 0.590 M2XH10x2.5 M104 10X2.5 0.660 M2XH14x1.5 M143 14X1.5 0.640 M2XH14x2.5 M144 14X2.5 0.710 M2XH20x1.5 M203 20X1.5 0.710 M2XH20x2.5 M204 20X2.5 0.800 M2XH30x1.5 M303 30X1.5 0.900 M2XH30x2.5 M304 30X2.5 1.040 For Low Smoke Zero Halogen Selection Guide, see pages 54-55. For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60.

M2XCH Low Smoke Zero Halogen Power and Control Cable, Shielded

Application: Used as control and communication cables in Construction: Electrolytic stranded annealed copper radio, radar and information systems for marine applications. conductors, IEC 60228 Class 5, (Class 2 and/or tinned on Enables proper transmission of high frequency signals while request). Low smoke, halogen free. XLP insulation. Electrolytic, minimizing environmental electromagnetic interference. copper-braided shield (90% coverage). M2XCH (EMC) type Usable in all conditions in marine environments such as dry, is wrapped by a copper tape in addition to this shield (100% wet or oily locations, and inside engine rooms. Rated at 60 coverage). Flame retardant, thermoplastic, polyolefin-based VDC/250 VAC. compound jacket (HM4/SHF1) HD 604. Color: gray. Specifications: Approved by American Bureau of Shipping, Bureau Veritas Lloyd’s Register of Shipping, GL, Class NK, RINA.

Summit Number Designation Size (mm2) O.D. (in.)

M2XCH7X1.5 MS-7-3 7X1.5 0.500 M2XCH7X2.5 MS-7-4 7X2.5 0.570 M2XCH10X1.5 MS-10-3 10X1.5 0.640 M2XCH10X2.5 MS-10-4 10X2.5 0.710 M2XCH14X1.5 MS-14-3 14X1.5 0.700 M2XCH14X2.5 MS-14-4 14X2.5 0.770 M2XCH20X1.5 MS-20-3 20X1.5 0.780 M2XCH20X2.5 MS-20-4 20X2.5 0.850 M2XCH30X1.5 MS-30-3 30X1.5 0.950 M2XCH30X2.5 MS-30-4 30X2.5 1.060 For a Low Smoke Zero Halogen Selection Guide, see pages 54-55. For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60.

4 888.326.5174 • summit.com/marine Low Smoke Zero Halogen Instrumentation

FM2XAH Overall Shielded Instrumentation Cable

Application: Used as control and communication cables in Construction: Electrolytic stranded annealed copper radio, radar and information systems for marine applications. conductors, IEC 60228 Class 5 (Class 2 and/or tinned on Enables proper transmission of high frequency signals while request). Low smoke, halogen free. XLP insulation. Separating minimizing environmental electromagnetic interference. foil below shield. Electrolytic tinned stranded copper drain wire Usable in all conditions in marine environments such as dry, below shield. Aluminum tape shield (100% coverage). Flame wet or oily locations, and inside engine rooms. Rated at 60 retardant, thermoplastic, polyolefin-based compound jacket VDC/250 VAC. (HM4/SHF1) HD 604. Color: gray. Specifications: Approved by American Bureau of Shipping, Lloyd’s Register of Shipping, Bureau Veritas, GL, Class NK, RINA.

Summit Number Designation Size (mm2) Nominal O.D. (in.)

FM2XAH1x2x1.5 TPS161P 1X2X1.5 0.370 FM2XAH1x2x0.75 TPS181P 1X2X0.75 0.310 FM2XAH1x2x0.5 TPS201P 1X2X0.5 0.280 FM2XAH1x3x1.5 TTS161 1X3X1.5 0.390 For a Low Smoke Zero Halogen Selection Guide, see pages 54-55. For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60.

FM2XAAH, Individual and Overall Shielded Instrumentation Cable

Application: Used as control and communication cables in Construction: Electrolytic stranded annealed copper radio, radar and information systems for marine applications. conductors, IEC 60228 Class 5, (Class 2 and/or tinned on Enables proper transmission of high frequency signals while request). Low smoke, halogen free. XLP insulation. Separating minimizing environmental electromagnetic interference. Usable foil over pairs/triads. Drain wire is electrolytic, tinned, stranded in all conditions in marine environments such as dry, wet or oily copper drain wire along each pair/triad. Aluminum tape shield locations, and inside engine rooms. Rated at 60 VDC/250 VAC. over each pair/triad and drain wire bunch, 1 coverage. Flame retardant, thermoplastic, polyolefin-based compound jacket Specifications: Approved by American Bureau of Shipping, (HM4/SHF1) – HD 604. Color: gray. Bureau Veritas, Lloyd’s Register of Shipping, GL, Class NK, RINA.

Summit Number Designation Size (mm2) Nominal O.D. (in.)

FM2XAAH2x2x1.5 TPS162P 2X2X1.5 0.610 FM2XAAH2x2x0.75 TPS182P 2X2X0.75 0.500 FM2XAAH2x2x0.5 TPS202P 2X2X0.5 0.460 FM2XAAH4x2x1.5 TPS164P 4X2X1.5 0.720 FM2XAAH4x2x0.75 TPS184P 4X2X0.75 0.580 FM2XAAH4x2x0.5 TPS204P 4X2X0.5 0.540 FM2XAAH6x2x1.5 TSP166P 6X2X1.5 0.870 FM2XAAH6x2x0.75 TPS186P 6X2X0.75 0.700 FM2XAAH6x2x0.5 TPS206P 6X2X0.5 0.650 FM2XAAH10x2x1.5 TPS1610P 10X2X1.5 1.080 FM2XAAH10x2x0.75 TPS1810P 10X2X0.75 0.870 FM2XAAH10x2x0.5 TPS2010P 10X2X0.5 0.800 FM2XAAH12x2x1.5 TPS1612P 12X2X1.5 1.130 FM2XAAH14x2x1.5 TPS1614P 14X2X1.5 1.240 Put Up: Stock items, order to length. Nonstock items, minimum order lengths apply. For a Low Smoke Zero Halogen Selection Guide, see pages 54-55. For Terminal Selection Guide, see page 56. For Gland Selection Guide, see page 58. For Ampacity Guide, see page 60.

888.326.5174 • summit.com/marine 5 Type T/N Power/Distribution Cable

Marine Power/Distribution Cable, Type T/N, Unarmored, 600/1000 Volts

Application: For use in marine vessels and on fixed and floating 46 CFR111 .6011998 and U.S. Coast Guard notification letter. offshore facilities. Used for power distribution in circuits or Approved by UL and CSA as Type T/N (IEEE), American in lighting, communication and control in circuits. Maximum Bureau of Shipping, Lloyd’s Register of Shipping, United conductor operating temperature: 90°C. Rated at 600 volts. States Coast Guard. Specifications: IEEE 15802001 and IEEE 452002 (E217848) Construction: Uncoated, soft annealed stranded copper Certificate 1382396, Master Contract 158650. UL-309 conductors. Insulation dual listed for THHN/THWN (sizes (E217848) Certificate 1382396 and Master Contract 158650 (LR 1/0AWG and larger rated for CT use). Flame retardant and 84983) per CSA C22.2 No. 24595. Accepted per US Regulations abrasion, chemical, sunlight resistant PVC jacket and sheath.

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) Single Conductor SNIU4 14 19 0.20 5.1 30 45 SNIU6 12 19 0.22 5.6 40 60 SNIU10 10 19 0.25 6.4 58 86 SNIU16 8 19 0.31 7.7 87 130 SNIU26 6 19 0.34 8.7 124 184 SNIU41 4 19 0.41 10.4 188 280 SNIU66 2 19 0.47 12.0 276 411 SNIU83 1 19 0.56 14.2 364 541 SNIU106 1/0 19 0.60 15.2 442 657 SNIU133 2/0 19 0.64 16.3 538 801 SNIU168 3/0 19 0.69 17.6 659 980 SNIU212 4/0 19 0.75 19.0 809 1204 SNIU250 250 37 0.82 20.7 950 1414 SNIU300 300 37 0.91 23.1 1155 1718 SNIU350 350 37 0.96 24.3 1325 1971 SNIU400 400 37 1.00 25.5 1494 2223 SNIU500 500 37 1.09 27.6 1829 2722 SNIU600 600 61 1.19 30.1 2180 3245 SNIU750 750 61 1.29 32.7 2678 3985 SNIU1000 1000 61 1.44 36.5 3500 5209 2 Conductor DNIU4 14 19 0.32 8.1 65 97 DNIU6 12 19 0.36 9.0 88 130 DNIU10 10 19 0.42 10.7 128 191 DNIU16 8 19 0.56 14.1 215 319 DNIU26 6 19 0.63 16.0 300 446 DNIU41 4 19 0.77 19.5 454 675 DNIU66 2 19 0.93 23.5 694 1033 DNIU83 1 19 1.04 26.4 871 1296 DNIU106 1/0 19 1.12 28.5 1063 1582 DNIU133 2/0 19 1.21 30.7 1283 1910 DNIU168 3/0 19 1.31 33.2 1562 2324 DNIU212 4/0 19 1.42 36.1 1912 2845 DNIU250 250 37 1.56 39.5 2254 3355 DNIU300 300 37 1.72 43.8 2771 4124 DNIU350 350 37 1.82 46.3 3168 4715 DNIU400 400 37 1.91 48.6 3565 5306 DNIU500 500 37 2.08 52.8 4345 6466 DNIU600 600 61 2.28 57.8 5183 7713 DNIU750 750 61 2.48 63.0 6333 9424 3 Conductor TNIU4 14 19 0.33 8.5 77 115 TNIU6 12 19 0.38 9.5 107 159 TNIU10 10 19 0.45 11.3 167 249 TNIU16 8 19 0.59 14.9 279 415 TNIU26 6 19 0.67 17.0 397 591 TNIU41 4 19 0.82 20.8 610 908

Continued on page 8

6 888.326.5174 • summit.com/marine Specialists in Shipboard Cable Armoring

Everything You Need for Smooth Sailing from One Convenient Supplier

Low Smoke Summit Electric Supply’s Marine Division Zero Halogen Cable offers products and services for the construction, maintenance and repair of offshore vessels and Marine Cable drilling rigs, as well as for inland vessels.

Industrial Lighting • In-house cable braiding, custom-length shipboard or rig cables With in-house cable braiding capability and our large shipboard Intercom and and rig cable inventory, our skilled technicians can armor your Communication custom cable order within a week. Systems • Full line of marine electrical products from names you trust Summit is an authorized distributor of 200+ leading manufacturers, Transits and Glands including 70 of the biggest names in marine electrical products. Choose from our broad • Local service with a global reach selection of marine products We send products across the U.S. and over 50 countries worldwide. that meet most national and international certifications, including American Bureau of Shipping, Det Norske Veritas, Lloyd’s Register of Shipping, Underwriters Laboratories and U.S. Coast Guard standards. Marine Division Lighting products also meet Toll-Free: 888.326.5174 UL standards. [email protected] Type T/N Power/Distribution Cable

Marine Power/Distribution Cable, Type T/N, Unarmored, 600/1000 Volts

Continued from page 6

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) TNIU66 2 19 0.99 25.0 935 1392 TNIU83 1 19 1.11 28.2 1177 1752 TNIU106 1/0 19 1.20 30.4 1430 2129 TNIU133 2/0 19 1.29 32.8 1743 2594 TNIU168 3/0 19 1.40 35.5 2134 3176 TNIU212 4/0 19 1.52 38.6 2634 3920 TNIU250 250 37 1.73 43.8 3204 4769 TNIU300 300 37 1.84 46.7 3761 5597 TNIU350 350 37 1.94 49.4 4315 6422 TNIU400 400 37 2.04 51.9 4870 7248 TNIU500 500 37 2.22 56.4 5964 8875 TNIU600 600 61 2.44 61.9 7111 10583 TNIU750 750 61 2.66 67.5 8822 13128 4 Conductor FNIU4 14 19 0.36 9.2 97 144 FNIU6 12 19 0.41 10.4 135 202 FNIU10 10 19 0.49 12.4 214 319 FNIU16 8 19 0.64 16.4 357 531 FNIU26 6 19 0.73 18.6 512 761 FNIU41 4 19 0.94 23.9 824 1226 FNIU66 2 19 1.09 27.6 1206 1794 FNIU83 1 19 1.22 31.0 1521 2264 FNIU106 1/0 19 1.32 33.5 1857 2764 FNIU133 2/0 19 1.43 36.2 2266 3372 FNIU168 3/0 19 1.55 39.3 2779 4136 FNIU212 4/0 19 1.74 44.2 3528 5250 FNIU250 250 37 1.91 48.4 4150 6176 FNIU300 300 37 2.03 51.6 4917 7317 FNIU350 350 37 2.15 54.7 5653 8413 FNIU400 400 37 2.26 57.5 6376 9489 FNIU500 500 37 2.46 62.6 7829 11651 FNIU600 600 61 2.70 68.6 9354 13920 FNIU750 750 61 3.01 76.4 11672 17370

Marine Power/Distribution Cable, Type T/N, Aluminum Armored, 600/1000 Volts Application: For use in marine vessels and on fixed and floating 46 CFR111.6011998 and U.S. Coast Guard notification letter. offshore facilities. Used for power distribution in circuits or Approved by UL and CSA as Type T/N (IEEE), American in lighting, communication and control in circuits. Maximum Bureau of Shipping, Lloyd’s Register of Shipping, United conductor operating temperature: 90°C. Rated at 600 volts. States Coast Guard. Specifications: IEEE 15802001 and IEEE 452002 (E217848) Construction: Uncoated, soft annealed stranded copper Certificate 1382396, Master Contract 158650. UL-309 conductors. Insulation dual listed for THHN/THWN (sizes (E217848) Certificate 1382396 and Master Contract 158650 (LR 1/0AWG and larger rated for CT use). Flame retardant and 84983) per CSA C22.2 No. 24595. Accepted per US Regulations abrasion, chemical, sunlight resistant PVC jacket and sheath.

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) 2 Conductor DNIA4 14 19 0.37 9.3 82 122 DNIA6 12 19 0.41 10.3 107 158 DNIA10 10 19 0.47 12.0 151 224 DNIA16 8 19 0.61 15.4 244 362 DNIA26 6 19 0.68 17.2 332 495 DNIA41 4 19 0.82 20.8 493 734 Continued on page 9

8 888.326.5174 • summit.com/marine Type T/N Power/Distribution Cable

Marine Power/Distribution Cable, Type T/N, Aluminum Armored, 600/1000 Volts Continued from page 8

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) DNIA66 2 19 0.98 24.8 741 1103 DNIA83 1 19 1.09 27.7 924 1375 DNIA106 1/0 19 1.17 29.7 1120 1667 DNIA133 2/0 19 1.26 32.0 1345 2001 DNIA168 3/0 19 1.36 34.5 1628 2423 DNIA212 4/0 19 1.47 37.4 1984 2952 DNIA250 250 37 1.61 40.8 2333 3472 DNIA300 300 37 1.77 45.0 2858 4254 DNIA350 350 37 1.87 47.5 3260 4852 DNIA400 400 37 1.96 49.9 3662 5450 DNIA500 500 37 2.13 54.1 4450 6622 DNIA600 600 61 2.33 59.1 5298 7884 DNIA750 750 61 2.53 64.3 6458 9610 3 Conductor TNIA4 14 19 0.38 9.8 95 142 TNIA6 12 19 0.43 10.8 127 189 TNIA10 10 19 0.50 12.6 191 284 TNIA16 8 19 0.64 16.2 309 460 TNIA26 6 19 0.72 18.2 432 643 TNIA41 4 19 0.87 22.0 652 970 TNIA66 2 19 1.04 26.3 986 1467 TNIA83 1 19 1.16 29.4 1234 1836 TNIA106 1/0 19 1.25 31.6 1491 2219 TNIA133 2/0 19 1.34 34.0 1808 2691 TNIA168 3/0 19 1.45 36.8 2205 3281 TNIA212 4/0 19 1.57 39.8 2711 4034 TNIA250 250 37 1.78 45.1 3292 4898 TNIA300 300 37 1.89 48.0 3854 5735 TNIA350 350 37 1.99 50.6 4413 6568 TNIA400 400 37 2.09 53.2 4973 7401 TNIA500 500 37 2.27 57.7 6076 9041 TNIA600 600 61 2.49 63.1 7234 10765 TNIA750 750 61 2.71 68.7 8955 13327 4 Conductor FNIA4 14 19 0.41 10.5 116 173 FNIA6 12 19 0.46 11.7 157 234 FNIA10 10 19 0.54 13.7 240 357 FNIA16 8 19 0.69 17.6 390 581 FNIA26 6 19 0.78 19.9 549 817 FNIA41 4 19 0.99 25.1 872 1297 FNIA66 2 19 1.14 28.8 1261 1876 FNIA83 1 19 1.27 32.3 1583 2356 FNIA106 1/0 19 1.37 34.8 1924 2863 FNIA133 2/0 19 1.48 37.5 2338 3479 FNIA168 3/0 19 1.60 40.5 2857 4252 FNIA212 4/0 19 1.79 45.5 3615 5380 FNIA250 250 37 1.96 49.7 4246 6319 FNIA300 300 37 2.08 52.9 5020 7470 FNIA350 350 37 2.20 55.9 5762 8574 FNIA400 400 37 2.31 58.8 6490 9658 FNIA500 500 37 2.51 63.8 7953 11835 FNIA600 600 61 2.75 69.9 9490 14122 FNIA750 750 61 3.06 77.7 11823 17594

888.326.5174 • summit.com/marine 9 Type T/N Power/Distribution Cable

Marine Power/Distribution Cable, Type T/N, Bronze Armored, 600/1000 Volts Application: For use in marine vessels and on fixed and floating 46 CFR111.6011998 and U.S. Coast Guard notification letter. offshore facilities. Used for power distribution in circuits or Approved by UL and CSA as Type T/N (IEEE), American in lighting, communication and control in circuits. Maximum Bureau of Shipping, Lloyd’s Register of Shipping, United conductor operating temperature: 90°C. Rated at 600 volts. States Coast Guard. Specifications: IEEE 15802001 and IEEE 452002 (E217848) Construction: Uncoated, soft annealed stranded copper Certificate 1382396, Master Contract 158650. UL-309 conductors. Insulation dual listed for THHN/THWN (sizes (E217848) Certificate 1382396 and Master Contract 158650 (LR 1/0AWG and larger rated for CT use). Flame retardant and 84983) per CSA C22.2 No. 24595. Accepted per US Regulations abrasion, chemical, sunlight resistant PVC jacket and sheath.

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) 2 Conductor DNIB4 14 19 0.37 9.3 121 180 DNIB6 12 19 0.41 10.3 149 222 DNIB10 10 19 0.47 12.0 201 299 DNIB16 8 19 0.61 15.4 309 459 DNIB26 6 19 0.68 17.2 406 604 DNIB41 4 19 0.82 20.8 582 867 DNIB66 2 19 0.98 24.8 848 1263 DNIB83 1 19 1.09 27.7 1044 1553 DNIB106 1/0 19 1.17 29.7 1249 1859 DNIB133 2/0 19 1.26 32.0 1484 2208 DNIB168 3/0 19 1.36 34.5 1778 2646 DNIB212 4/0 19 1.47 37.4 2147 3194 DNIB250 250 37 1.61 40.8 2511 3737 DNIB300 300 37 1.77 45.0 3055 4546 DNIB350 350 37 1.87 47.5 3468 5160 DNIB400 400 37 1.96 49.9 3880 5774 DNIB500 500 37 2.13 54.1 4686 6974 DNIB600 600 61 2.33 59.1 5556 8269 DNIB750 750 61 2.53 64.3 6739 10029 3 Conductor TNIB4 14 19 0.38 9.8 136 202 TNIB6 12 19 0.43 10.8 172 256 TNIB10 10 19 0.50 12.6 244 363 TNIB16 8 19 0.64 16.2 378 563 TNIB26 6 19 0.72 18.2 510 759 TNIB41 4 19 0.87 22.0 747 1111 TNIB66 2 19 1.04 26.3 1100 1636 TNIB83 1 19 1.16 29.4 1361 2026 TNIB106 1/0 19 1.25 31.6 1628 2423 TNIB133 2/0 19 1.34 34.0 1956 2911 TNIB168 3/0 19 1.45 36.8 2365 3519 TNIB212 4/0 19 1.57 39.8 2884 4292 TNIB250 250 37 1.78 45.1 3488 5191 TNIB300 300 37 1.89 48.0 4063 6047 TNIB350 350 37 1.99 50.6 4635 6897 TNIB400 400 37 2.09 53.2 5206 7747 TNIB500 500 37 2.27 57.7 6328 9417 TNIB600 600 61 2.49 63.1 7511 11177 TNIB750 750 61 2.71 68.7 9257 13776 4 Conductor FNIB4 14 19 0.41 10.5 160 238 FNIB6 12 19 0.46 11.7 206 306 FNIB10 10 19 0.54 13.7 298 443 FNIB16 8 19 0.69 17.6 465 693 FNIB26 6 19 0.78 19.9 634 944 FNIB41 4 19 0.99 25.1 980 1458

Continued on page 11

10 888.326.5174 • summit.com/marine Type T/N Power/Distribution Cable, Control Cable

Marine Power/Distribution Cable, Type T/N, Bronze Armored, 600/1000 Volts Continued from page 10

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) FNIB66 2 19 1.14 28.8 1386 2062 FNIB83 1 19 1.27 32.3 1724 2565 FNIB106 1/0 19 1.37 34.8 2075 3088 FNIB133 2/0 19 1.48 37.5 2501 3722 FNIB168 3/0 19 1.60 40.5 3034 4515 FNIB212 4/0 19 1.79 45.5 3814 5676 FNIB250 250 37 1.96 49.7 4463 6642 FNIB300 300 37 2.08 52.9 5251 7814 FNIB350 350 37 2.20 55.9 6007 8939 FNIB400 400 37 2.31 58.8 6747 10041 FNIB500 500 37 2.51 63.8 8233 12252 FNIB600 600 61 2.75 69.9 9796 14579 FNIB750 750 61 3.06 77.7 12164 18102

Marine Control Cable, Type T/N, Unarmored, Multi-Conductor 600/1000 Volts Application: Used for marine environments, aboard marine (IEEE), American Bureau of Shipping, Lloyd’s Register of vessels and on fixed and floating offshore facilities. For control, Shipping, United States Coast Guard. indicating, communication, electronic and similar circuits Construction: Uncoated soft annealed copper conductors. where multiple conductors are needed. Rated for 600/1000 Flame retardant PVC insulation. Color coded per IEEE, UL, volts. CSA. Cabled round with moisture and flame retardant fillers. Specifications: IEEE 15802001, IEEE 452002. UL 13091995, Flame retardant, sunlight resistant PVC jacket. CSA C22.2 No. 245. Approved by UL and CSA as Type T/N

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) MNIU2(3) 16 26 2 0.29 7.0 49 73 MNIU3(3) 16 26 3 0.31 8.0 57 85 MNIU4(3) 16 26 4 0.33 8.0 70 105 MNIU7(3) 16 26 7 0.39 10.0 109 162 MNIU10(3) 16 26 10 0.49 12.0 152 226 MNIU14(3) 16 26 14 0.56 14.0 216 321 MNIU16(3) 16 26 16 0.59 15.0 244 363 MNIU19(3) 16 26 19 0.62 15.6 278 414 MNIU24(3) 16 26 24 0.71 18.0 363 540 MNIU30(3) 16 26 30 0.75 19.2 418 623 MNIU37(3) 16 26 37 0.81 20.6 503 749 MNIU40(3) 16 26 40 0.91 23.2 601 895 MNIU61(3) 16 26 61 1.05 26.6 835 1242 MNIU2(4) 14 19 2 0.32 8.1 64 95 MNIU3(4) 14 19 3 0.33 8.5 76 113 MNIU4(4) 14 19 4 0.36 9.2 95 141 MNIU7(4) 14 19 7 0.43 10.9 150 224 MNIU10(4) 14 19 10 0.57 14.5 226 337 MNIU14(4) 14 19 14 0.62 15.6 298 444 MNIU16(4) 14 19 16 0.65 16.4 338 503 MNIU19(4) 14 19 19 0.68 17.3 389 578 MNIU24(4) 14 19 24 0.78 19.9 507 755 MNIU30(4) 14 19 30 0.88 22.3 623 927 MNIU37(4) 14 19 37 0.94 23.9 749 1115 MNIU40(4) 14 19 40 1.01 25.7 839 1249 MNIU61(4) 14 19 61 1.16 29.6 1184 1761 Continued on page 12

888.326.5174 • summit.com/marine 11 Type T/N Control Cable

Marine Control Cable, Type T/N, Unarmored, Multi-Conductor 600/1000 Volts Continued from page 11

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) MNIU2(6) 12 19 2 0.36 9.0 86 127 MNIU3(6) 12 19 3 0.38 9.5 105 156 MNIU4(6) 12 19 4 0.41 10.4 133 198 MNIU7(6) 12 19 7 0.49 12.3 215 319 MNIU10(6) 12 19 10 0.65 16.4 320 476 MNIU14(6) 12 19 14 0.70 17.8 427 636 MNIU16(6) 12 19 16 0.74 18.7 486 723 MNIU19(6) 12 19 19 0.78 19.7 561 835 MNIU24(6) 12 19 24 0.94 23.8 768 1142 MNIU30(6) 12 19 30 1.00 25.4 897 1335 MNIU37(6) 12 19 37 1.08 27.3 1084 1613 MNIU40(6) 12 19 40 1.16 29.4 1212 1803 MNIU61(6) 12 19 61 1.34 33.9 1728 2572

Marine Control Cable, Type T/N, Aluminum Armored, Multi-Conductor 600/1000 Volts Application: Used for marine environments, aboard marine (IEEE), American Bureau of Shipping, Lloyd’s Register of vessels and on fixed and floating offshore facilities. For control, Shipping, United States Coast Guard. indicating, communication, electronic and similar circuits Construction: Uncoated soft annealed copper conductors. where multiple conductors are needed. Rated for 600/1000 Flame retardant PVC insulation. Color coded per IEEE, UL, volts. CSA. Cabled round with moisture and flame retardant fillers. Specifications: IEEE 15802001, IEEE 452002. UL 13091995, Flame retardant, sunlight resistant PVC jacket. CSA C22.2 No. 245. Approved by UL and CSA as Type T/N

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) MNIA2(3) 16 26 2 0.34 8.7 65 96 MNIA3(3) 16 26 3 0.36 9.0 73 109 MNIA4(3) 16 26 4 0.38 9.7 88 131 MNIA7(3) 16 26 7 0.44 11.2 130 193 MNIA10(3) 16 26 10 0.54 13.6 177 264 MNIA14(3) 16 26 14 0.61 15.4 245 364 MNIA16(3) 16 26 16 0.64 16.2 274 408 MNIA19(3) 16 26 19 0.67 16.9 310 461 MNIA24(3) 16 26 24 0.76 19.2 400 595 MNIA30(3) 16 26 30 0.80 20.4 457 680 MNIA37(3) 16 26 37 0.86 21.9 545 811 MNIA40(3) 16 26 40 0.96 24.4 648 964 MNIA61(3) 16 26 61 1.10 27.9 888 1322 MNIA2(4) 14 19 2 0.37 9.3 81 120 MNIA3(4) 14 19 3 0.38 9.8 94 139 MNIA4(4) 14 19 4 0.41 10.5 114 170 MNIA7(4) 14 19 7 0.48 12.1 173 257 MNIA10(4) 14 19 10 0.62 15.7 256 381 MNIA14(4) 14 19 14 0.67 16.9 330 491 MNIA16(4) 14 19 16 0.70 17.7 372 553 MNIA19(4) 14 19 19 0.73 18.5 424 631 MNIA24(4) 14 19 24 0.83 21.2 547 815 MNIA30(4) 14 19 30 0.93 23.5 668 994 MNIA37(4) 14 19 37 0.99 25.2 797 1187 MNIA40(4) 14 19 40 1.06 26.9 891 1325 MNIA61(4) 14 19 61 1.21 30.8 1243 1849

Continued on page 13

12 888.326.5174 • summit.com/marine Type T/N Control Cable

Marine Control Cable, Type T/N, Aluminum Armored, Multi-Conductor 600/1000 Volts Continued from page 12

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) MNIA2(6) 12 19 2 0.41 10.3 104 156 MNIA3(6) 12 19 3 0.43 10.8 125 186 MNIA4(6) 12 19 4 0.46 11.7 155 230 MNIA7(6) 12 19 7 0.54 13.6 240 357 MNIA10(6) 12 19 10 0.70 17.7 353 526 MNIA14(6) 12 19 14 0.75 19.0 463 689 MNIA16(6) 12 19 16 0.79 20.0 524 780 MNIA19(6) 12 19 19 0.83 21.0 601 894 MNIA24(6) 12 19 24 0.99 25.1 816 1214 MNIA30(6) 12 19 30 1.05 26.6 948 1411 MNIA37(6) 12 19 37 1.13 28.6 1139 1695 MNIA40(6) 12 19 40 1.21 30.6 1270 1891 MNIA61(6) 12 19 61 1.39 35.2 1796 2672

Marine Control Cable, Type T/N, Bronze Armored, Multi-Conductor 600/1000 Volts Application: Used for marine environments, aboard marine (IEEE), American Bureau of Shipping, Lloyd’s Register of vessels and on fixed and floating offshore facilities. For control, Shipping, United States Coast Guard. indicating, communication, electronic and similar circuits Construction: Uncoated soft annealed copper conductors. where multiple conductors are needed. Rated for 600/1000 Flame retardant PVC insulation. Color coded per IEEE, UL, volts. CSA. Cabled round with moisture and flame retardant fillers. Specifications: IEEE 15802001, IEEE 452002. UL 13091995, Flame retardant, sunlight resistant PVC jacket. CSA C22.2 No. 245. Approved by UL and CSA as Type T/N

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) MNIB2(3) 16 26 2 0.34 8.7 100 149 MNIB3(3) 16 26 3 0.36 9.0 111 165 MNIB4(3) 16 26 4 0.38 9.7 128 191 MNIB7(3) 16 26 7 0.44 11.2 176 262 MNIB10(3) 16 26 10 0.54 13.6 235 349 MNIB14(3) 16 26 14 0.61 15.4 310 462 MNIB16(3) 16 26 16 0.64 16.2 343 511 MNIB19(3) 16 26 19 0.67 16.9 382 569 MNIB24(3) 16 26 24 0.76 19.2 482 717 MNIB30(3) 16 26 30 0.80 20.4 545 811 MNIB37(3) 16 26 37 0.86 21.9 639 951 MNIB40(3) 16 26 40 0.96 24.4 753 1121 MNIB61(3) 16 26 61 1.10 27.9 1009 1501 MNIB2(4) 14 19 2 0.37 9.3 119 177 MNIB3(4) 14 19 3 0.38 9.8 134 199 MNIB4(4) 14 19 4 0.41 10.5 158 235 MNIB7(4) 14 19 7 0.48 12.1 224 333 MNIB10(4) 14 19 10 0.62 15.7 323 480 MNIB14(4) 14 19 14 0.67 16.9 402 598 MNIB16(4) 14 19 16 0.70 17.7 447 666 MNIB19(4) 14 19 19 0.73 18.5 503 749 MNIB24(4) 14 19 24 0.83 21.2 638 950 MNIB30(4) 14 19 30 0.93 23.5 769 1145 MNIB37(4) 14 19 37 0.99 25.2 906 1349 MNIB40(4) 14 19 40 1.06 26.9 1007 1499 MNIB61(4) 14 19 61 1.21 30.8 1376 2048

Continued on page 14

888.326.5174 • summit.com/marine 13 Type T/N Control Cable

Marine Control Cable, Type T/N, Bronze Armored, Multi-Conductor 600/1000 Volts Continued from page 13

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) MNIB2(6) 12 19 2 0.41 10.3 147 219 MNIB3(6) 12 19 3 0.43 10.8 170 253 MNIB4(6) 12 19 4 0.46 11.7 203 303 MNIB7(6) 12 19 7 0.54 13.6 297 442 MNIB10(6) 12 19 10 0.70 17.7 429 638 MNIB14(6) 12 19 14 0.75 19.0 545 810 MNIB16(6) 12 19 16 0.79 20.0 609 907 MNIB19(6) 12 19 19 0.83 21.0 691 1028 MNIB24(6) 12 19 24 0.99 25.1 924 1375 MNIB30(6) 12 19 30 1.05 26.6 1063 1582 MNIB37(6) 12 19 37 1.13 28.6 1263 1879 MNIB40(6) 12 19 40 1.21 30.6 1403 2088 MNIB61(6) 12 19 61 1.39 35.2 1949 2900

The Roxtec Sealing System Roxtec sealing solutions for cables and pipes ensure safety, efficiency and long-term operational reliability in many different industries.

Multidiameter™ by Roxtec Our invention for adaptability, Multidiameter™, is a solution based on rubber modules with removable layers. It allows for a perfect sealing, regardless of the outside dimension of the cable or pipe. This simplifies design, speeds up installation and reduces the need for stock, material and logistics. It also provides built-in spare capacity for future upgrades. Certified safety seals Our seals protect people and investments against risks caused by, for example, fire, gas, water, dust, pests, blast load, and electro- magnetic interference. The system is tested and approved by all major classification societies and used in a wide range of applications. Two main product groups There are two main groups of Roxtec products to choose from. The type of application and requirements of protection determine which product to choose. Both groups, RM and CM, are available also in the EMC application area, as well as in the EX application area.

Learn more at summit.com/marine

14 888.326.5174 • summit.com/marine Type T/N Signal & Instrumentation

Marine Signal & Instrumentation, Type T/N, Pairs, IS/OS Shielded Cable, Unarmored, Multi-Conductor 600/1000 Volts Application: For use in marine environments, aboard marine American Bureau of Shipping, Lloyd’s Register of Shipping, vessels and on fixed and floating offshore facilities. Twisted United States Coast Guard. pairs used for signal transmission. Individual or overall group Construction: Bare soft annealed stranded copper conductors shielding is to prevent electrostatic and electromagnetic in twisted, black and white pairs. Color coded with sequential interference. For use in circuits rated for 300 volts. Maximum printed numbers. Flame and moisture resistant fillers and operating temperature: 90°C. binder tape. Abrasion, chemical and sunlight resistant PVC Specifications: IEEE 15802001, IEEE 452002. UL-13091995, overall jacket. Flame retardant PVC insulation. CSA C22.2 No. 245. IEC 92350. Approved by UL, CSA,

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) TPS20TIU2 20 10 2 0.43 10.9 70 104 TPS20TIU3 20 10 3 0.45 11.5 87 130 TPS20TIU4 20 10 4 0.50 12.6 107 159 TPS20TIU5 20 10 5 0.57 14.6 143 213 TPS20TIU6 20 10 6 0.62 15.8 165 245 TPS20TIU8 20 10 8 0.67 17.0 201 299 TPS20TIU10 20 10 10 0.79 20.0 246 366 TPS20TIU15 20 10 15 0.94 23.9 373 554 TPS20TIU20 20 10 20 1.04 26.4 464 691 TPS20TIU25 20 10 25 1.18 29.9 563 837 TPS20TIU30 20 10 30 1.22 31.0 645 959 TPS20TIU40 20 10 40 1.37 34.7 819 1219 TPS20TIU50 20 10 50 1.55 39.4 1000 1488 TPS20TIU60 20 10 60 1.65 41.8 1166 1735 TPS18TIU2 18 16 2 0.46 11.8 86 129 TPS18TIU3 18 16 3 0.49 12.5 110 164 TPS18TIU4 18 16 4 0.57 14.5 152 227 TPS18TIU5 18 16 5 0.62 15.8 180 268 TPS18TIU6 18 16 6 0.68 17.2 208 310 TPS18TIU8 18 16 8 0.73 18.6 257 382 TPS18TIU10 18 16 10 0.90 22.8 351 522 TPS18TIU15 18 16 15 1.03 26.0 477 709 TPS18TIU20 18 16 20 1.14 28.8 600 892 TPS18TIU25 18 16 25 1.29 32.8 730 1087 TPS18TIU30 18 16 30 1.34 34.0 843 1254 TPS18TIU40 18 16 40 1.50 38.1 1079 1605 TPS18TIU50 18 16 50 1.76 44.7 1427 2123 TPS18TIU60 18 16 60 1.87 47.4 1660 2470 TPS16TIU2 16 26 2 0.51 13.0 106 158 TPS16TIU3 16 26 3 0.57 14.6 155 230 TPS16TIU4 16 26 4 0.63 15.9 190 283 TPS16TIU5 16 26 5 0.69 17.4 226 337 TPS16TIU6 16 26 6 0.75 19.0 263 391 TPS16TIU8 16 26 8 0.81 20.6 327 487 TPS16TIU10 16 26 10 0.99 25.2 442 658 TPS16TIU15 16 26 15 1.14 28.9 609 906 TPS16TIU20 16 26 20 1.26 32.1 772 1149 TPS16TIU25 16 26 25 1.44 36.5 944 1405 TPS16TIU30 16 26 30 1.49 37.9 1095 1630 TPS16TIU40 16 26 40 1.73 44.0 1513 2252 TPS16TIU50 16 26 50 1.96 49.9 1850 2753 TPS16TIU60 16 26 60 2.08 52.9 2162 3217

888.326.5174 • summit.com/marine 15 Type T/N Signal & Instrumentation

Marine Signal & Instrumentation, Type T/N, Pairs, IS/OS Shielded Cable, Aluminum Armored, Multi-Conductor 600/1000 Volts Application: For use in marine environments, aboard marine American Bureau of Shipping, Det Norske Veritas, Lloyd’s vessels and on fixed and floating offshore facilities. Twisted Register of Shipping, United States Coast Guard. pairs used for signal transmission. Individual or overall group Construction: Bare soft annealed stranded copper conductors shielding is to prevent electrostatic and electromagnetic in twisted, black and white pairs. Color coded with sequential interference. For use in circuits rated for 300 volts. Maximum printed numbers. Flame and moisture resistant fillers and operating temperature: 90°C. binder tape. Standard aluminum armor. Abrasion, chemical Specifications: IEEE 15802001, IEEE 452002. UL-13091995, and sunlight resistant PVC overall jacket. Flame retardant PVC CSA C22.2 No. 245. IEC 92350. Approved by UL, CSA, insulation.

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) TPS20TIA2 20 10 2 0.48 12.1 93 138 TPS20TIA3 20 10 3 0.50 12.8 111 166 TPS20TIA4 20 10 4 0.55 13.9 133 197 TPS20TIA5 20 10 5 0.62 15.8 173 257 TPS20TIA6 20 10 6 0.67 17.1 197 293 TPS20TIA8 20 10 8 0.72 18.3 235 350 TPS20TIA10 20 10 10 0.84 21.2 286 426 TPS20TIA15 20 10 15 0.99 25.2 421 626 TPS20TIA20 20 10 20 1.09 27.7 517 769 TPS20TIA25 20 10 25 1.23 31.2 623 927 TPS20TIA30 20 10 30 1.27 32.3 707 1052 TPS20TIA40 20 10 40 1.42 36.0 888 1322 TPS20TIA50 20 10 50 1.60 40.6 1078 1604 TPS20TIA60 20 10 60 1.70 43.1 1249 1858 TPS18TIA2 18 16 2 0.51 13.1 111 165 TPS18TIA3 18 16 3 0.54 13.8 136 202 TPS18TIA4 18 16 4 0.62 15.7 182 271 TPS18TIA5 18 16 5 0.67 17.0 212 316 TPS18TIA6 18 16 6 0.73 18.4 243 361 TPS18TIA8 18 16 8 0.78 19.8 295 438 TPS18TIA10 18 16 10 0.95 24.1 396 590 TPS18TIA15 18 16 15 1.08 27.3 529 787 TPS18TIA20 18 16 20 1.19 30.1 657 978 TPS18TIA25 18 16 25 1.34 34.0 796 1184 TPS18TIA30 18 16 30 1.39 35.2 910 1355 TPS18TIA40 18 16 40 1.55 39.3 1155 1718 TPS18TIA50 18 16 50 1.81 46.0 1515 2255 TPS18TIA60 18 16 60 1.92 48.7 1754 2610 TPS16TIA2 16 26 2 0.56 14.3 133 198 TPS16TIA3 16 26 3 0.62 15.8 185 275 TPS16TIA4 16 26 4 0.68 17.2 223 331 TPS16TIA5 16 26 5 0.74 18.7 262 389 TPS16TIA6 16 26 6 0.80 20.3 301 448 TPS16TIA8 16 26 8 0.86 21.8 369 549 TPS16TIA10 16 26 10 1.04 26.5 493 734 TPS16TIA15 16 26 15 1.19 30.2 667 992 TPS16TIA20 16 26 20 1.31 33.3 836 1244 TPS16TIA25 16 26 25 1.49 37.8 1017 1513 TPS16TIA30 16 26 30 1.54 39.1 1170 1742 TPS16TIA40 16 26 40 1.78 45.3 1601 2382 TPS16TIA50 16 26 50 2.01 51.1 1949 2900 TPS16TIA60 16 26 60 2.13 54.2 2267 3374

16 888.326.5174 • summit.com/marine Type T/N Signal & Instrumentation

Marine Signal & Instrumentation, Type T/N, Pairs, IS/OS Shielded Cable, Bronze Armored, Multi-Conductor 600/1000 Volts Application: For use in marine environments, aboard marine American Bureau of Shipping, Det Norske Veritas, Lloyd’s vessels and on fixed and floating offshore facilities. Twisted Register of Shipping, United States Coast Guard. pairs used for signal transmission. Individual or overall group Construction: Bare soft annealed stranded copper conductors shielding is to prevent electrostatic and electromagnetic in twisted, black and white pairs. Color coded with sequential interference. For use in circuits rated for 300 volts. Maximum printed numbers. Flame and moisture resistant fillers and operating temperature: 90°C. binder tape. Standard bronze armor. Abrasion, chemical and Specifications: IEEE 15802001, IEEE 452002. UL-13091995, sunlight resistant PVC overall jacket. Flame retardant PVC CSA C22.2 No. 245. IEC 92350. Approved by UL, CSA, insulation.

Summit Size # of # of Outside Diameter Weight Number (AWG) Strands Conductors (in.) (mm) (lbs./1000 ft.) (kg/km) TPS20TIB2 20 10 2 0.48 12.1 143 214 TPS20TIB3 20 10 3 0.50 12.8 165 246 TPS20TIB4 20 10 4 0.55 13.9 191 285 TPS20TIB5 20 10 5 0.62 15.8 240 357 TPS20TIB6 20 10 6 0.67 17.1 269 401 TPS20TIB8 20 10 8 0.72 18.3 314 467 TPS20TIB10 20 10 10 0.84 21.2 377 561 TPS20TIB15 20 10 15 0.99 25.2 529 788 TPS20TIB20 20 10 20 1.09 27.7 637 947 TPS20TIB25 20 10 25 1.23 31.2 758 1128 TPS20TIB30 20 10 30 1.27 32.3 847 1261 TPS20TIB40 20 10 40 1.42 36.0 1045 1555 TPS20TIB50 20 10 50 1.60 40.6 1255 1868 TPS20TIB60 20 10 60 1.70 43.1 1437 2138 TPS18TIB2 18 16 2 0.51 13.1 166 247 TPS18TIB3 18 16 3 0.54 13.8 194 289 TPS18TIB4 18 16 4 0.62 15.7 249 370 TPS18TIB5 18 16 5 0.67 17.0 285 424 TPS18TIB6 18 16 6 0.73 18.4 322 479 TPS18TIB8 18 16 8 0.78 19.8 380 565 TPS18TIB10 18 16 10 0.95 24.1 500 745 TPS18TIB15 18 16 15 1.08 27.3 647 963 TPS18TIB20 18 16 20 1.19 30.1 788 1172 TPS18TIB25 18 16 25 1.34 34.0 944 1404 TPS18TIB30 18 16 30 1.39 35.2 1064 1583 TPS18TIB40 18 16 40 1.55 39.3 1326 1973 TPS18TIB50 18 16 50 1.81 46.0 1716 2554 TPS18TIB60 18 16 60 1.92 48.7 1967 2927 TPS16TIB2 16 26 2 0.56 14.3 193 288 TPS16TIB3 16 26 3 0.62 15.8 252 375 TPS16TIB4 16 26 4 0.68 17.2 296 440 TPS16TIB5 16 26 5 0.74 18.7 342 508 TPS16TIB6 16 26 6 0.80 20.3 388 577 TPS16TIB8 16 26 8 0.86 21.8 463 689 TPS16TIB10 16 26 10 1.04 26.5 608 904 TPS16TIB15 16 26 15 1.19 30.2 798 1187 TPS16TIB20 16 26 20 1.31 33.3 981 1460 TPS16TIB25 16 26 25 1.49 37.8 1181 1758 TPS16TIB30 16 26 30 1.54 39.1 1341 1995 TPS16TIB40 16 26 40 1.78 45.3 1799 2677 TPS16TIB50 16 26 50 2.01 51.1 2173 3233 TPS16TIB60 16 26 60 2.13 54.2 2504 3726

888.326.5174 • summit.com/marine 17 Type P Power/Distribution Cable

Marine Power/Distribution Cable, Type P, 2kV

Application: For marine environments, offshore drilling American Bureau of Shipping, Det Norske Veritas, Lloyd’s rigs, aboard marine vessels and on fixed and floating offshore Register of Shipping, United States Coast Guard. facilities. For power distribution in circuits rated for 2,000 volts. Construction: Tin-coated, soft annealed copper conductors. Some common applications are DC motor cables, generators, Flame retardant, sunlight resistant XLPO insulation. Flame transformers and top drives. retardant, sunlight resistant CP overall jacket. Standards: IEEE 15802001 and IEEE 452002. UL-13091995. CSA C22.2 No. 245. Approved by UL and CSA as Type P,

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) Unarmored DSHP211 4/0 551 0.87 22.10 885 1317 DSHP262 262.6 646 0.92 23.50 1021 1519 DSHP313 313.1 779 0.99 25.20 1209 1799 DSHP373 373.7 925 1.06 26.90 1414 2104 DSHP444 444.4 1110 1.14 29.00 1672 2489 DSHP535 535.3 1332 1.26 32.00 2020 3006 DSHP646 646.4 1591 1.35 34.30 2380 3542 DSHP777 777.7 1924 1.46 37.10 2841 4228 DSHP1111 1111.1 2745 1.69 43.00 3968 5905 Bronze Armored and Sheathed DSHPBS211 4/0 551 1.10 28.0 1203 1791 DSHPBS262 262.6 646 1.16 29.4 1356 2018 DSHPBS313 313.1 779 1.22 31.1 1567 2332 DSHPBS373 373.7 925 1.29 32.8 1795 2671 DSHPBS444 444.4 1110 1.37 34.8 2079 3095 DSHPBS535 535.3 1332 1.49 37.9 2467 3671 DSHPBS646 646.4 1591 1.58 40.2 2857 4252 DSHPBS777 777.7 1924 1.69 43.0 3354 4991 DSHPBS1111 1111.1 2745 1.99 50.0 4681 6967

A2F Cable Glands Triton CDS Cable Connector PX2KX Cable Connector (T3CDS) The CMP A2F Tri-Star Cable Gland is The CMP PX2KX cable connector offers suitable for use with all forms of equipment The T3CDS cable connector is available Nema 4X and IP68 ingress protection and protection permitted in Zone 1, Zone 2, in NPT (standard) or Metric thread forms is supplied in Brass grade CuZn39Pb3 Zone 21 & Zone 22 provided always that and the standard material is Brass grade (CW614N) to EN12168 with Electroless the prevailing code of practice for selection, CuZn39Pb3 (CW614N) to EN12168 with Nickel Plated Brass entry component as installation and maintenance is observed, Electroless Nickel Plated Brass entry standard. component. e.g. IEC 60079-14. The PX2KX is also IEC Ex Triple Certified Suitable for hazardous areas with unarmored This product provides Nema 4X and IP68 Ex d, Ex e & Ex nR, offering a single solution and braided cable providing a combined ingress protection and is UL listed for use that can be employed in accordance with flameproof seal and environmental seal in Class I Zone 1 AEx e II applications and both NEC and IEC codes of installation. on the cable outer sheath. This product can be used in Class I Division 2 areas provides full compatibility with restricted when installed in compliance with the NEC® breathing equipment. requirements.

CABLE GLAND AND CABLE CONNECTION SPECIALISTS

18 888.326.5174 • summit.com/marine Type P Power/Distribution Cable

Marine Power/Distribution Cable, Type P, Single Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine Shipping, Det Norske Veritas, Lloyd’s Register of Shipping, United vessels, and on fixed and floating offshore facilities where States Coast Guard. harsh marine environments exist. Used in control, indicating, Construction: Flexible tin-coated, soft annealed copper conductors communication, electronic, and similar circuits where multiple with polyester separator tape, color coded. Flame retardant, conductor cables are required. Typical applications include driller’s sunlight resistant XLPO insulation. Conductors cabled round with console, fire and gas detection systems, video camera systems, moisture and flame retardant fillers. Flame retardant, sunlight bilge and ballast controls and general alarm systems. Temperature resistant CP jacket. rating: 110°C. Specifications:IEEE 15802001, IEEE 452002. UL 13091995. CSA C22.2 No. 245. Approved by UL, CSA, TCMS, American Bureau of

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) Unarmored DSSPCP1 18 19 0.12 3.0 11 17 DSSPCP3 16 19 0.13 3.2 14 21 DSSPCP4 14 19 0.14 3.6 20 29 DSSPCP6 12 19 0.16 4.1 28 42 DSSPCP10 10 27 0.19 4.9 45 67 DSSPCP16 8 37 0.25 6.3 66 98 DSSPCP26 6 63 0.31 7.9 107 159 DSSPCP41 4 105 0.37 9.4 167 248 DSSPCP66 2 154 0.43 10.9 235 350 DSSPCP83 1 224 0.51 13.1 342 509 DSSPCP105 1/0 273 0.56 14.1 410 610 DSSPCP133 2/0 323 0.61 15.6 485 722 DSSPCP167 3/0 456 0.70 17.9 669 996 DSSPCP211 4/0 551 0.76 19.3 799 1190 DSSPCP262 262.6 646 0.84 21.3 947 1410 DSSPCP313 313.1 779 0.90 23.0 1130 1681 DSSPCP373 373.7 925 0.97 24.7 1329 1978 DSSPCP444 444.4 1110 1.05 26.7 1581 2353 DSSPCP535 535.3 1332 1.17 29.8 1919 2855 DSSPCP646 646.4 1591 1.26 32.1 2271 3380 DSSPCP777 777.7 1924 1.37 34.8 2723 4052 DSSPCP1111 1111.1 2745 1.67 42.4 3932 5851 Bronze Armored and Sheathed DSSPBS1 18 19 0.27 6.9 56 84 DSSPBS3 16 19 0.28 7.2 61 91 DSSPBS4 14 19 0.30 7.6 71 106 DSSPBS6 12 19 0.32 8.1 85 127 DSSPBS10 10 27 0.35 8.9 110 163 DSSPBS16 8 37 0.41 10.3 145 216 DSSPBS26 6 63 0.47 11.9 201 300 DSSPBS41 4 105 0.53 13.4 277 412 DSSPBS66 2 154 0.62 15.6 379 564 DSSPBS83 1 224 0.70 17.9 511 760 DSSPBS105 1/0 273 0.74 18.9 591 879 DSSPBS133 2/0 323 0.80 20.3 682 1015 DSSPBS167 3/0 456 0.94 23.8 932 1386 DSSPBS211 4/0 551 0.99 25.2 1081 1609 DSSPBS262 262.6 646 1.07 27.2 1254 1866 DSSPBS313 313.1 779 1.14 28.9 1459 2171 DSSPBS373 373.7 925 1.21 30.6 1681 2502 DSSPBS444 444.4 1110 1.28 32.6 1959 2916 DSSPBS535 535.3 1332 1.40 35.7 2336 3477 DSSPBS646 646.4 1591 1.50 38.0 2719 4047 DSSPBS777 777.7 1924 1.60 40.7 3207 4773 DSSPBS1111 1111.1 2745 1.96 50.0 4636 6899

888.326.5174 • summit.com/marine 19 Type P Power/Distribution Cable

Marine Power/Distribution Cable, Type P, 2 Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine Bureau of Shipping, Det Norske Veritas, Lloyd’s Register of vessels, and on fixed and floating offshore facilities where harsh Shipping, United States Coast Guard. marine environments exist. Common applications are AC Construction: Flexible tin-coated, soft annealed copper motor power, distribution panel feeder, transformer feeder, conductors with polyester separator tape, color coded. Flame lighting panels, light fixtures, plugs, receptacles and remote retardant, sunlight resistant XLPO insulation. Cabled round motor controls. Temperature rating: 110°C. with moisture and flame retardant fillers. Flame retardant, Specifications: IEEE 15802001, IEEE 452002, UL 13091995, sunlight resistant CP jacket. CSA C22.2 No. 245. Approved by UL, CSA, TCMS, American

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) 2 Conductor - Unarmored DDPCP16 8 37 0.67 17.0 239 356 DDPCP26 6 63 0.79 20.0 349 520 DDPCP41 4 105 0.95 24.0 542 807 DDPCP66 2 154 1.07 27.0 720 1072 DDPCP83 1 224 1.24 32.0 995 1480 DDPCP105 1/0 273 1.32 34.0 1162 1730 DDPCP133 2/0 323 1.44 37.0 1360 2024 DDPCP167 3/0 456 1.62 41.0 1809 2692 DDPCP211 4/0 551 1.73 44.0 2121 3157 DDPCP262 262.6 646 1.95 50.0 2614 3890 DDPCP313 313.1 779 2.09 53.0 3056 4547 DDPCP373 373.7 925 2.22 56.0 3541 5270 DDPCP444 444.4 1110 2.38 60.0 4149 6174 DDPCP535 535.3 1332 2.62 67.0 4978 7409 DDPCP646 646.4 1591 2.80 71.0 5817 8657 2 Conductor - Bronze Armored and Sheathed DDPCPBS16 8 37 0.93 23.7 499 742 DDPCPBS26 6 63 1.05 26.7 650 967 DDPCPBS41 4 105 1.22 30.9 898 1337 DDPCPBS66 2 154 1.33 33.8 1114 1659 DDPCPBS83 1 224 1.51 38.3 1448 2155 DDPCPBS105 1/0 273 1.59 40.3 1643 2445 DDPCPBS133 2/0 323 1.70 43.2 1879 2796 DDPCPBS167 3/0 456 1.95 49.5 2511 3736 DDPCPBS211 4/0 551 2.06 52.4 2868 4269 DDPCPBS262 262.6 646 2.28 57.9 3448 5131 DDPCPBS313 313.1 779 2.41 61.3 3943 5868 DDPCPBS373 373.7 925 2.55 64.8 4484 6673 DDPCPBS444 444.4 1110 2.71 68.8 5155 7671 DDPCPBS535 535.3 1332 3.02 76.6 6274 9337 DDPCPBS646 646.4 1591 3.20 81.3 7198 10712

20 888.326.5174 • summit.com/marine Type P Power/Distribution Cable

Marine Power/Distribution Cable, Type P, 3 Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine Bureau of Shipping, Det Norske Veritas, Lloyd’s Register of vessels, and on fixed and floating offshore facilities where harsh Shipping, United States Coast Guard. marine environments exist. Common applications are AC Construction: Flexible tin-coated, soft annealed copper motor power, distribution panel feeder, transformer feeder, conductors with polyester separator tape, color coded. Flame lighting panels, light fixtures, plugs, receptacles and remote retardant, sunlight resistant XLPO insulation. Cabled round motor controls. Temperature rating: 110°C. with moisture and flame retardant fillers. Flame retardant, Specifications: IEEE 15802001, IEEE 452002, UL 13091995, sunlight resistant CP jacket. CSA C22.2 No. 245. Approved by UL, CSA, TCMS, American

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) 3 Conductor - Unarmored DTPCP16 8 37 0.71 17.9 309 459 DTPCP26 6 63 0.84 21.2 460 684 DTPCP41 4 105 1.01 25.6 717 1068 DTPCP66 2 154 1.13 28.8 963 1433 DTPCP83 1 224 1.32 33.6 1347 2005 DTPCP105 1/0 273 1.41 35.8 1586 2360 DTPCP133 2/0 323 1.53 38.9 1855 2760 DTPCP167 3/0 456 1.73 43.9 2491 3707 DTPCP211 4/0 551 1.92 48.7 3055 4546 DTPCP262 262.6 646 2.08 52.9 3580 5328 DTPCP313 313.1 779 2.23 56.6 4210 6265 DTPCP373 373.7 925 2.37 60.3 4895 7285 DTPCP444 444.4 1110 2.54 64.6 5757 8568 DTPCP535 535.3 1332 2.80 71.2 6926 10307 DTPCP646 646.4 1591 3.07 77.9 8312 12370 3 Conductor - Bronze Armored and Sheathed DTPCPBS16 8 37 0.97 24.6 581 865 DTPCPBS26 6 63 1.1 27.9 776 1155 DTPCPBS41 4 105 1.27 32.4 1093 1626 DTPCPBS66 2 154 1.4 35.5 1380 2053 DTPCPBS83 1 224 1.59 40.3 1827 2719 DTPCPBS105 1/0 273 1.67 42.5 2095 3118 DTPCPBS133 2/0 323 1.86 47.3 2521 3752 DTPCPBS167 3/0 456 2.06 52.3 3236 4816 DTPCPBS211 4/0 551 2.25 57 3875 5766 DTPCPBS262 262.6 646 2.41 61.2 4466 6646 DTPCPBS313 313.1 779 2.56 64.9 5154 7670 DTPCPBS373 373.7 925 2.7 68.7 5898 8777 DTPCPBS444 444.4 1110 2.94 74.7 7018 10444 DTPCPBS535 535.3 1332 3.2 81.2 8306 12360

888.326.5174 • summit.com/marine 21 Type P Power/Distribution Cable

Marine Power/Distribution Cable, Type P, 4 Conductor, XLPO/CP, 600/1000 Volts Application: For use on offshore drilling rigs, aboard marine Bureau of Shipping, Det Norske Veritas, Lloyd’s Register of vessels, and on fixed and floating offshore facilities where harsh Shipping, United States Coast Guard. marine environments exist. Common applications are AC Construction: Flexible tin-coated, soft annealed copper motor power, distribution panel feeder, transformer feeder, conductors with polyester separator tape, color coded. Flame lighting panels, light fixtures, plugs, receptacles and remote retardant, sunlight resistant XLPO insulation. Cabled round motor controls. Temperature rating: 110°C. with moisture and flame retardant fillers. Flame retardant, Specifications: IEEE 15802001, IEEE 452002, UL 13091995, sunlight resistant CP jacket. CSA C22.2 No. 245. Approved by UL, CSA, TCMS, American

Summit Size # of Outside Diameter Weight Number (AWG/kcmil) Strands (in.) (mm) (lbs./1000 ft.) (kg/km) 4 Conductor - Unarmored DFPCP16 8 37 0.77 19.6 388 577 DFPCP26 6 63 0.96 24.4 624 928 DFPCP41 4 105 1.11 28.1 910 1354 DFPCP66 2 154 1.24 31.6 1231 1833 DFPCP83 1 224 1.45 37.0 1732 2577 DFPCP105 1/0 273 1.55 39.4 2042 3039 DFPCP133 2/0 323 1.69 43.0 2395 3565 DFPCP167 3/0 456 1.98 50.2 3347 4980 DFPCP211 4/0 551 2.11 53.7 3941 5864 DFPCP262 262.6 646 2.30 58.4 4631 6892 DFPCP313 313.1 779 2.46 62.5 5455 8118 DFPCP373 373.7 925 2.63 66.7 6352 9453 DFPCP444 444.4 1110 2.82 71.6 7482 11134 DFPCP535 535.3 1332 3.17 80.6 9219 13719 DFPCP646 646.4 1591 3.39 86.2 10806 16081 4 Conductor - Bronze Armored and Sheathed DFPCPBS16 8 37 1.03 26.3 682 1015 DFPCPBS26 6 63 1.22 31.1 982 1462 DFPCPBS41 4 105 1.37 34.8 1317 1961 DFPCPBS66 2 154 1.51 38.3 1685 2508 DFPCPBS83 1 224 1.72 43.7 2257 3358 DFPCPBS105 1/0 273 1.88 47.8 2716 4042 DFPCPBS133 2/0 323 2.02 51.3 3125 4651 DFPCPBS167 3/0 456 2.30 58.5 4190 6236 DFPCPBS211 4/0 551 2.44 62.1 4840 7202 DFPCPBS262 262.6 646 2.63 66.7 5604 8339 DFPCPBS313 313.1 779 2.79 70.8 6493 9662 DFPCPBS373 373.7 925 3.02 76.8 7651 11386 DFPCPBS444 444.4 1110 3.21 81.6 8869 13199

22 888.326.5174 • summit.com/marine Type P Control Cable

Marine Control Cable, Type P, 600 Volts

Application: For use on offshore drilling rigs, aboard marine Bureau of Shipping, Det Norske Veritas, Lloyd’s Register of vessels, and on fixed and floating offshore facilities where Shipping, United States Coast Guard. harsh marine environments exist. Used in control, indicating, Construction: Flexible tin-coated, soft annealed copper communication, electronic and similar circuits where multiple conductors with polyester separator tape, color coded. Flame conductor cables are required. Used for driller’s console, fire and retardant, sunlight resistant XLPO insulation. Cabled round gas detection systems, video camera systems, bilge and ballast with moisture and flame retardant fillers. Flame retardant, controls and general alarm systems. Temperature rating: 110°C. abrasion and sunlight resistant CP jacket. Specifications: IEEE 15802001, IEEE 452002, UL 13091995, CSA C22.2 No. 245. Approved by UL, CSA, TCMS, American

Summit # of Jacket Thickness Outside Diameter Weight Number Conductors (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) 16 AWG, 26 Strands - Unarmored DC16PCP2 2 45 1.22 0.39 9.90 71 105 DC16PCP3 3 45 1.22 0.41 10.4 86 129 DC16PCP4 4 45 1.22 0.44 11.2 105 156 DC16PCP5 5 45 1.22 0.48 12.1 121 180 DC16PCP6 6 45 1.22 0.51 13.1 140 209 DC16PCP7 7 45 1.22 0.51 13.1 151 225 DC16PCP8 8 60 1.60 0.62 15.8 200 298 DC16PCP9 9 60 1.60 0.66 16.9 223 332 DC16PCP10 10 60 1.60 0.67 17.1 229 341 DC16PCP12 12 60 1.60 0.69 17.6 261 388 DC16PCP14 14 60 1.60 0.72 18.4 295 438 DC16PCP16 16 60 1.60 0.76 19.3 331 493 DC16PCP18 18 60 1.60 0.80 20.3 366 544 DC16PCP19 19 60 1.60 0.80 20.3 377 561 DC16PCP20 20 60 1.60 0.84 21.2 402 598 DC16PCP22 22 80 2.13 0.92 23.4 478 711 DC16PCP24 24 80 2.13 0.96 24.4 517 770 DC16PCP30 30 80 2.13 1.02 25.9 605 901 DC16PCP37 37 80 2.13 1.09 27.8 721 1072 DC16PCP44 44 80 2.13 1.21 30.8 858 1276 DC16PCP45 45 80 2.13 1.21 30.8 869 1294 DC16PCP60 60 80 2.13 1.34 34.2 1106 1646 DC16PCP91 91 80 2.13 1.60 40.5 1600 2381 16 AWG, 26 Strands - Bronze Armored and Sheathed DC16PCPBS2 2 60 1.60 0.61 15.5 207 307 DC16PCPBS3 3 60 1.60 0.63 16.0 229 340 DC16PCPBS4 4 60 1.60 0.66 16.8 257 382 DC16PCPBS5 5 60 1.60 0.70 17.7 285 424 DC16PCPBS6 6 60 1.60 0.74 18.7 316 470 DC16PCPBS7 7 60 1.60 0.74 18.7 327 487 DC16PCPBS8 8 60 1.60 0.84 21.4 408 608 DC16PCPBS9 9 80 2.10 0.93 23.6 482 717 DC16PCPBS10 10 80 2.10 0.94 23.8 490 730 DC16PCPBS12 12 80 2.10 0.96 24.3 529 787 DC16PCPBS14 14 80 2.10 0.99 25.1 573 853 DC16PCPBS16 16 80 2.10 1.02 26.0 621 924 DC16PCPBS18 18 80 2.10 1.06 27.0 669 996 DC16PCPBS19 19 80 2.10 1.06 27.0 681 1013 DC16PCPBS20 20 80 2.10 1.10 27.9 718 1069 DC16PCPBS22 22 80 2.10 1.18 30.1 822 1224 DC16PCPBS24 24 80 2.10 1.22 31.1 875 1303 DC16PCPBS30 30 80 2.10 1.28 32.6 984 1464 DC16PCPBS37 37 80 2.10 1.36 34.5 1124 1672 DC16PCPBS44 44 80 2.10 1.48 37.5 1301 1936 DC16PCPBS45 45 80 2.10 1.48 37.5 1312 1953 DC16PCPBS60 60 80 2.10 1.61 40.9 1593 2371 DC16PCPBS91 91 110 2.90 1.93 48.9 2292 3411 Continued on page 24

888.326.5174 • summit.com/marine 23 Type P Control Cable

Marine Control Cable, Type P, 600 Volts

Continued from page 23

Summit # of Jacket Thickness Outside Diameter Weight Number Conductors (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) 14 AWG, 41 Strands - Unarmored DC14PCP2 2 45 1.22 0.42 10.7 87 130 DC14PCP3 3 45 1.22 0.44 11.2 109 162 DC14PCP4 4 45 1.22 0.48 12.2 134 200 DC14PCP5 5 45 1.22 0.52 13.2 156 232 DC14PCP6 6 60 1.60 0.59 15.1 200 298 DC14PCP7 7 60 1.60 0.59 15.1 216 321 DC14PCP8 8 60 1.60 0.68 17.3 258 383 DC14PCP9 9 60 1.60 0.73 18.4 288 429 DC14PCP10 10 60 1.60 0.73 18.6 297 443 DC14PCP12 12 60 1.60 0.76 19.2 342 508 DC14PCP14 14 60 1.60 0.79 20.1 388 577 DC14PCP16 16 60 1.60 0.83 21.2 438 652 DC14PCP18 18 80 2.13 0.92 23.4 523 778 DC14PCP19 19 80 2.13 0.92 23.4 540 804 DC14PCP20 20 80 2.13 0.96 24.4 574 855 DC14PCP22 22 80 2.13 1.01 25.6 627 933 DC14PCP24 24 80 2.13 1.05 26.7 680 1012 DC14PCP30 30 80 2.13 1.12 28.4 803 1195 DC14PCP37 37 80 2.13 1.20 30.5 962 1431 DC14PCP44 44 80 2.13 1.34 33.9 1147 1706 DC14PCP45 45 80 2.13 1.34 33.9 1164 1732 DC14PCP60 60 80 2.13 1.49 37.7 1492 2220 DC14PCP91 91 110 2.92 1.83 46.5 2290 3407 14 AWG, 41 Strands - Bronze Armored and Sheathed DC14PCPBS2 2 60 1.60 0.64 16.3 232 345 DC14PCPBS3 3 60 1.60 0.66 16.8 261 388 DC14PCPBS4 4 60 1.60 0.70 17.8 296 441 DC14PCPBS5 5 60 1.60 0.74 18.8 332 494 DC14PCPBS6 6 60 1.60 0.81 20.7 398 592 DC14PCPBS7 7 60 1.60 0.81 20.7 415 617 DC14PCPBS8 8 80 2.10 0.94 24.0 522 776 DC14PCPBS9 9 80 2.10 0.99 25.1 568 845 DC14PCPBS10 10 80 2.10 1.00 25.4 580 863 DC14PCPBS12 12 80 2.10 1.02 25.9 631 939 DC14PCPBS14 14 80 2.10 1.06 26.8 690 1027 DC14PCPBS16 16 80 2.10 1.10 27.9 752 1119 DC14PCPBS18 18 80 2.10 1.18 30.1 868 1291 DC14PCPBS19 19 80 2.10 1.18 30.1 885 1317 DC14PCPBS20 20 80 2.10 1.23 31.1 934 1389 DC14PCPBS22 22 80 2.10 1.27 32.3 1001 1490 DC14PCPBS24 24 80 2.10 1.32 33.4 1070 1592 DC14PCPBS30 30 80 2.10 1.38 35.1 1215 1808 DC14PCPBS37 37 80 2.10 1.47 37.2 1402 2086 DC14PCPBS44 44 80 2.10 1.60 40.6 1631 2428 DC14PCPBS45 45 80 2.10 1.60 40.6 1648 2453 DC14PCPBS60 60 110 2.90 1.81 46.1 2138 3182 DC14PCPBS91 91 110 2.90 2.16 54.9 3076 4578 12 AWG, 65 Strands - Unarmored DC12PCP2 2 45 1.22 0.46 11.7 112 167 DC12PCP3 3 45 1.22 0.48 12.3 143 213 DC12PCP4 4 45 1.22 0.53 13.4 178 265 DC12PCP5 5 60 1.60 0.60 15.3 227 338 DC12PCP6 6 60 1.60 0.65 16.6 265 394 DC12PCP7 7 60 1.60 0.65 16.6 288 429

Continued on page 25

24 888.326.5174 • summit.com/marine Type P Control Cable

Marine Control Cable, Type P, 600 Volts

Continued from page 24

Summit # of Jacket Thickness Outside Diameter Weight Number Conductors (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) DC12PCP8 8 60 1.60 0.75 19.1 344 512 DC12PCP9 9 60 1.60 0.80 20.4 386 574 DC12PCP10 10 60 1.60 0.81 20.7 401 597 DC12PCP12 12 60 1.60 0.84 21.3 464 691 DC12PCP14 14 80 2.13 0.92 23.5 568 845 DC12PCP16 16 80 2.13 0.97 24.6 640 953 DC12PCP18 18 80 2.13 1.02 25.9 708 1054 DC12PCP19 19 80 2.13 1.02 25.9 734 1092 DC12PCP20 20 80 2.13 1.07 27.1 780 1161 DC12PCP22 22 80 2.13 1.12 28.4 853 1270 DC12PCP24 24 80 2.13 1.17 29.7 927 1380 DC12PCP30 30 80 2.13 1.25 31.6 1104 1643 DC12PCP37 37 80 2.13 1.34 34.1 1329 1978 DC12PCP44 44 80 2.13 1.49 37.9 1587 2362 DC12PCP45 45 80 2.13 1.49 37.9 1612 2399 DC12PCP60 60 80 2.13 1.66 42.2 2080 3096 DC12PCP91 91 110 2.92 2.05 52.1 3185 4739 12 AWG, 65 Strands - Bronze Armored and Sheathed DC12PCPBS2 2 60 1.60 0.68 17.3 267 398 DC12PCPBS3 3 60 1.60 0.71 17.9 306 455 DC12PCPBS4 4 60 1.60 0.75 19.0 353 526 DC12PCPBS5 5 60 1.60 0.82 20.9 427 636 DC12PCPBS6 6 80 2.10 0.92 23.3 518 771 DC12PCPBS7 7 80 2.10 0.92 23.3 543 808 DC12PCPBS8 8 80 2.10 1.02 25.8 632 941 DC12PCPBS9 9 80 2.10 1.07 27.1 692 1029 DC12PCPBS10 10 80 2.10 1.08 27.4 710 1056 DC12PCPBS12 12 80 2.10 1.10 28.0 781 1163 DC12PCPBS14 14 80 2.10 1.19 30.2 914 1360 DC12PCPBS16 16 80 2.10 1.23 31.4 1000 1488 DC12PCPBS18 18 80 2.10 1.28 32.6 1086 1616 DC12PCPBS19 19 80 2.10 1.28 32.6 1111 1654 DC12PCPBS20 20 80 2.10 1.33 33.8 1175 1748 DC12PCPBS22 22 80 2.10 1.38 35.1 1265 1882 DC12PCPBS24 24 80 2.10 1.43 36.4 1356 2018 DC12PCPBS30 30 80 2.10 1.51 38.4 1559 2319 DC12PCPBS37 37 80 2.10 1.60 40.8 1816 2702 DC12PCPBS44 44 110 2.90 1.82 46.3 2238 3330 DC12PCPBS45 45 110 2.90 1.82 46.3 2263 3367 DC12PCPBS60 60 110 2.90 1.99 50.6 2798 4164 DC12PCPBS91 91 110 2.90 2.38 60.4 4058 6039 10 AWG, 105 Strands - Unarmored DC10PCP2 2 45 1.22 0.52 13.3 153 227 DC10PCP3 3 60 1.60 0.58 14.8 216 321 DC10PCP4 4 60 1.60 0.63 16.1 269 401 DC10PCP5 5 60 1.60 0.69 17.5 316 471 DC10PCP6 6 60 1.60 0.75 18.9 371 552 DC10PCP7 7 60 1.60 0.75 18.9 407 606 DC10PCP8 8 80 2.13 0.91 23.1 524 779 DC10PCP9 9 80 2.13 0.97 24.6 586 872 DC10PCP10 10 80 2.13 0.98 24.9 611 910 DC10PCP12 12 80 2.13 1.01 25.7 707 1052 DC10PCP14 14 80 2.13 1.06 27.0 806 1199 DC10PCP16 16 80 2.13 1.12 28.4 912 1357 DC10PCP18 18 80 2.13 1.17 29.8 1011 1505

Continued on page 26

888.326.5174 • summit.com/marine 25 Type P Control Cable

Marine Control Cable, Type P, 600 Volts

Continued from page 25

Summit # of Jacket Thickness Outside Diameter Weight Number Conductors (mils) (mm) (in.) (mm) (lbs./1000 ft.) (kg/km) DC10PCP19 19 80 2.13 1.17 29.8 1050 1563 DC10PCP20 20 80 2.13 1.23 31.3 1117 1662 DC10PCP22 22 80 2.13 1.29 32.9 1224 1821 DC10PCP24 24 80 2.13 1.36 34.4 1331 1981 DC10PCP30 30 80 2.13 1.45 36.7 1596 2375 DC10PCP37 37 80 2.13 1.56 39.6 1931 2873 DC10PCP44 44 110 2.92 1.80 45.8 2420 3601 DC10PCP45 45 110 2.92 1.80 45.8 2459 3659 DC10PCP60 60 110 2.92 2.01 51.0 3170 4717 DC10PCP91 91 110 2.92 2.39 60.8 4651 6922 10 AWG, 105 Strands - Bronze Armored and Sheathed DC10PCPBS2 2 60 1.60 0.74 18.9 324 482 DC10PCPBS3 3 60 1.60 0.80 20.4 407 605 DC10PCPBS4 4 60 1.60 0.85 21.7 474 706 DC10PCPBS5 5 80 2.10 0.95 24.2 580 864 DC10PCPBS6 6 80 2.10 1.01 25.6 656 976 DC10PCPBS7 7 80 2.10 1.01 25.6 693 1032 DC10PCPBS8 8 80 2.10 1.17 29.8 865 1287 DC10PCPBS9 9 80 2.10 1.23 31.4 948 1411 DC10PCPBS10 10 80 2.10 1.25 31.6 977 1454 DC10PCPBS12 12 80 2.10 1.28 32.4 1083 1611 DC10PCPBS14 14 80 2.10 1.33 33.7 1198 1784 DC10PCPBS16 16 80 2.10 1.38 35.1 1320 1965 DC10PCPBS18 18 80 2.10 1.44 36.5 1442 2146 DC10PCPBS19 19 80 2.10 1.44 36.5 1481 2203 DC10PCPBS20 20 80 2.10 1.50 38.0 1567 2332 DC10PCPBS22 22 80 2.10 1.56 39.6 1695 2522 DC10PCPBS24 24 80 2.10 1.62 41.1 1823 2713 DC10PCPBS30 30 80 2.10 1.71 43.5 2118 3153 DC10PCPBS37 37 110 2.90 1.89 47.9 2608 3881 DC10PCPBS44 44 110 2.90 2.13 54.2 3195 4755 DC10PCPBS45 45 110 2.90 2.13 54.2 3234 4813 DC10PCPBS60 60 110 2.90 2.34 59.4 4025 5990 DC10PCPBS91 91 110 2.90 2.72 69.1 5662 8426

26 888.326.5174 • summit.com/marine Type P Signal & Instrumentation

Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, 300-600/1000 Volts Application: For use in signal transmission applications where of Shipping, Det Norske Veritas, Lloyd’s Register of Shipping, maximum protection from electromagnetic interference is United States Coast Guard. needed. For use in marine environments on offshore drilling Construction: Flexible tin-coated, soft annealed copper rigs, aboard marine vessels, or on fixed and floating offshore conductors, twisted pairs or triads color coded with sequential facilities. Used in tank level indicators, fire and gas protection printed numbers. Pairs use black and white; triads use black, systems, communication systems, CO2 systems, and smoke white, red. Flame retardant, sunlight resistant XLPO insulation. detectors. Temperature rating: 110°C. Cabled round with moisture and flame resistant fillers and Specifications: IEEE 15802001, IEEE 452002. UL-1685, UL binder tape. Individual and overall shielding with aluminum/ 13091995. CSA C22.2 No. 245. IEEE 383 and 1202 Flame Tests. polyester tape, 100% coverage, and drain wire. Flame retardant, ICEA T30820. IEC 332 Category A 210,000 BTU/hr Flame Test. sunlight resistant CP jacket. Standard bronze armor. Oil, ICEA T29520. Approved by UL, CSA, TCMS, American Bureau chemical, sunlight and abrasion resistant CP sheathing.

Summit # of Outside Diameter Weight Number Pairs (in.) (mm) (lbs./1000 ft.) (kg/km) Pairs - 20 AWG, 10 Strands - Unarmored DTPS20PCP1 1 0.31 8.0 45 68 DTPS20PCP2 2 0.54 13.7 94 140 DTPS20PCP3 3 0.60 15.3 136 202 DTPS20PCP4 4 0.66 16.7 164 243 DTPS20PCP5 5 0.72 18.3 192 286 DTPS20PCP6 6 0.78 19.9 221 329 DTPS20PCP7 7 0.78 19.9 241 359 DTPS20PCP8 8 0.85 21.6 270 402 DTPS20PCP10 10 1.04 26.5 375 558 DTPS20PCP12 12 1.08 27.3 421 627 DTPS20PCP14 14 1.13 28.7 471 701 DTPS20PCP16 16 1.19 30.3 523 778 DTPS20PCP17 17 1.26 31.9 554 825 DTPS20PCP19 19 1.26 31.9 595 885 DTPS20PCP20 20 1.32 33.5 627 932 DTPS20PCP24 24 1.47 37.4 734 1092 Pairs - 20 AWG, 10 Strands - Bronze Armored and Sheathed DTPS20PCPBS1 1 0.47 12.0 143 213 DTPS20PCPBS2 2 0.73 18.5 273 406 DTPS20PCPBS3 3 0.79 20.1 334 497 DTPS20PCPBS4 4 0.85 21.5 378 562 DTPS20PCPBS5 5 0.95 24.2 464 690 DTPS20PCPBS6 6 1.02 25.8 515 766 DTPS20PCPBS7 7 1.02 25.8 535 796 DTPS20PCPBS8 8 1.08 27.4 586 871 DTPS20PCPBS10 10 1.27 32.4 755 1124 DTPS20PCPBS12 12 1.31 33.2 813 1209 DTPS20PCPBS14 14 1.36 34.6 882 1312 DTPS20PCPBS16 16 1.42 36.2 954 1419 DTPS20PCPBS17 17 1.49 37.8 1007 1499 DTPS20PCPBS19 19 1.49 37.8 1047 1559 DTPS20PCPBS20 20 1.55 39.4 1101 1638 DTPS20PCPBS24 24 1.70 43.2 1259 1873 Pairs - 18 AWG, 16 Strands - Unarmored DTPS18PCP1 1 0.33 8.5 54 80 DTPS18PCP2 2 0.61 15.5 131 195 DTPS18PCP3 3 0.65 16.5 163 243 DTPS18PCP4 4 0.71 18.0 198 295 DTPS18PCP5 5 0.78 19.7 234 349 DTPS18PCP6 6 0.85 21.5 271 403 DTPS18PCP7 7 0.85 21.5 298 443 DTPS18PCP8 8 0.96 24.4 375 557 DTPS18PCP10 10 1.13 28.6 458 681 DTPS18PCP12 12 1.16 29.5 518 771

Continued on page 28

888.326.5174 • summit.com/marine 27 Type P Signal & Instrumentation

Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, 300-600/1000 Volts Continued from page 27

Summit # of Outside Diameter Weight Number Pairs (in.) (mm) (lbs./1000 ft.) (kg/km) DTPS18PCP14 14 1.22 31.1 583 868 DTPS18PCP16 16 1.29 32.8 649 965 DTPS18PCP17 17 1.36 34.6 688 1024 DTPS18PCP19 19 1.36 34.6 742 1104 DTPS18PCP20 20 1.43 36.3 782 1163 DTPS18PCP24 24 1.60 40.5 919 1367 Pairs - 18 AWG, 16 Strands - Bronze Armored and Sheathed DTPS18PCPBS1 1 0.49 12.5 157 234 DTPS18PCPBS2 2 0.80 20.3 332 493 DTPS18PCPBS3 3 0.84 21.2 374 557 DTPS18PCPBS4 4 0.94 23.9 467 695 DTPS18PCPBS5 5 1.01 25.6 525 782 DTPS18PCPBS6 6 1.08 27.4 586 871 DTPS18PCPBS7 7 1.08 27.4 612 911 DTPS18PCPBS8 8 1.19 30.3 728 1083 DTPS18PCPBS10 10 1.36 34.5 866 1289 DTPS18PCPBS12 12 1.39 35.4 939 1397 DTPS18PCPBS14 14 1.45 37.0 1024 1524 DTPS18PCPBS16 16 1.52 38.6 1113 1656 DTPS18PCPBS17 17 1.59 40.4 1176 1750 DTPS18PCPBS19 19 1.59 40.4 1230 1830 DTPS18PCPBS20 20 1.66 42.2 1293 1924 DTPS18PCPBS24 24 1.89 48.1 1603 2385 Pairs - 16 AWG, 26 Strands - Unarmored DTPS16PCP1 1 0.36 9.2 67 100 DTPS16PCP2 2 0.67 16.9 162 241 DTPS16PCP3 3 0.71 17.9 205 306 DTPS16PCP4 4 0.77 19.7 252 376 DTPS16PCP5 5 0.85 21.6 300 447 DTPS16PCP6 6 0.97 24.7 389 580 DTPS16PCP7 7 0.97 24.7 427 636 DTPS16PCP8 8 1.05 26.7 479 713 DTPS16PCP10 10 1.23 31.3 587 874 DTPS16PCP12 12 1.27 32.4 670 997 DTPS16PCP14 14 1.34 34.1 758 1127 DTPS16PCP16 16 1.42 36.0 846 1260 DTPS16PCP17 17 1.50 38.0 898 1337 DTPS16PCP19 19 1.50 38.0 974 1449 DTPS16PCP20 20 1.57 40.0 1026 1526 DTPS16PCP24 24 1.82 46.3 1322 1968 Pairs - 16 AWG, 26 Strands - Bronze Armored and Sheathed DTPS16PCPBS1 1 0.52 13.2 178 264 DTPS16PCPBS2 2 0.85 21.7 378 563 DTPS16PCPBS3 3 0.94 23.8 473 703 DTPS16PCPBS4 4 1.01 25.5 542 807 DTPS16PCPBS5 5 1.08 27.4 616 916 DTPS16PCPBS6 6 1.20 30.6 746 1110 DTPS16PCPBS7 7 1.20 30.6 784 1166 DTPS16PCPBS8 8 1.28 32.6 862 1283 DTPS16PCPBS10 10 1.47 37.2 1032 1536 DTPS16PCPBS12 12 1.51 38.3 1129 1680 DTPS16PCPBS14 14 1.57 40.0 1239 1844 DTPS16PCPBS16 16 1.65 41.9 1353 2014 DTPS16PCPBS17 17 1.73 43.9 1432 2130 DTPS16PCPBS19 19 1.73 43.9 1507 2243 Continued on page 29

28 888.326.5174 • summit.com/marine Type P Signal & Instrumentation

Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, 300-600/1000 Volts Continued from page 28

Summit # of Outside Diameter Weight Number Pairs (in.) (mm) (lbs./1000 ft.) (kg/km) DTPS16PCPBS20 20 1.87 47.5 1701 2532 DTPS16PCPBS24 24 2.12 53.8 2097 3121 Pairs - 14 AWG, 41 Strands - Unarmored DTPS14PCP1 1 0.39 10.0 85 127 DTPS14PCP2 2 0.73 18.5 205 305 DTPS14PCP3 3 0.77 19.7 265 394 DTPS14PCP4 4 0.85 21.6 329 489 DTPS14PCP5 5 0.98 24.8 434 646 DTPS14PCP6 6 1.06 27.1 503 749 DTPS14PCP7 7 1.06 27.1 557 829 DTPS14PCP8 8 1.15 29.3 626 932 DTPS14PCP10 10 1.36 34.5 770 1145 DTPS14PCP12 12 1.40 35.7 885 1317 DTPS14PCP14 14 1.48 37.6 1005 1496 DTPS14PCP16 16 1.56 39.7 1127 1677 DTPS14PCP17 17 1.65 41.9 1196 1780 DTPS14PCP19 19 1.65 41.9 1303 1939 DTPS14PCP20 20 1.80 45.8 1484 2208 DTPS14PCP24 24 2.01 51.0 1747 2600 Pairs - 14 AWG, 41 Strands - Bronze Armored and Sheathed DTPS14PCPBS1 1 0.58 14.8 221 330 DTPS14PCPBS2 2 0.96 24.4 480 714 DTPS14PCPBS3 3 1.01 25.5 555 826 DTPS14PCPBS4 4 1.08 27.5 644 959 DTPS14PCPBS5 5 1.21 30.7 793 1179 DTPS14PCPBS6 6 1.30 32.9 892 1327 DTPS14PCPBS7 7 1.30 32.9 945 1406 DTPS14PCPBS8 8 1.39 35.2 1044 1554 DTPS14PCPBS10 10 1.59 40.4 1257 1870 DTPS14PCPBS12 12 1.64 41.6 1387 2064 DTPS14PCPBS14 14 1.71 43.5 1533 2282 DTPS14PCPBS16 16 1.86 47.2 1798 2676 DTPS14PCPBS17 17 1.95 49.5 1903 2832 DTPS14PCPBS19 19 1.95 49.5 2010 2991 DTPS14PCPBS20 20 2.10 53.4 2252 3351 DTPS14PCPBS24 24 2.31 58.6 2597 3865 Triads - 18 AWG, 16 Strands - Unarmored DTTS18PCP1 1 0.35 9.0 66 99 DTTS18PCP2 2 0.65 16.4 158 235 DTTS18PCP3 3 0.69 17.4 201 299 DTTS18PCP4 4 0.75 19.1 248 369 DTTS18PCP5 5 0.82 20.9 295 440 DTTS18PCP6 6 0.94 24.0 383 570 DTTS18PCP7 7 0.94 24.0 421 626 DTTS18PCP8 8 1.02 25.9 472 703 DTTS18PCP10 10 1.20 30.4 579 862 DTTS18PCP12 12 1.24 31.4 662 985 DTTS18PCP14 14 1.30 33.0 749 1115 DTTS18PCP16 16 1.37 34.9 838 1247 DTTS18PCP17 17 1.45 36.8 889 1323 DTTS18PCP19 19 1.45 36.8 965 1436 DTTS18PCP20 20 1.52 38.7 1016 1512 DTTS18PCP24 24 1.70 43.2 1199 1784

Continued on page 30

888.326.5174 • summit.com/marine 29 Type P Signal & Instrumentation

Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, 300-600/1000 Volts Continued from page 29

Summit # of Outside Diameter Weight Number Pairs (in.) (mm) (lbs./1000 ft.) (kg/km) Triads - 18 AWG, 16 Strands - Bronze Armored and Sheathed DTTS18PCPBS1 1 0.50 12.8 174 259 DTTS18PCPBS2 2 0.83 21.1 368 548 DTTS18PCPBS3 3 0.91 23.2 461 686 DTTS18PCPBS4 4 0.98 24.9 530 788 DTTS18PCPBS5 5 1.05 26.7 601 895 DTTS18PCPBS6 6 1.17 29.7 729 1085 DTTS18PCPBS7 7 1.17 29.7 767 1141 DTTS18PCPBS8 8 1.25 31.6 844 1256 DTTS18PCPBS10 10 1.42 36.1 1011 1504 DTTS18PCPBS12 12 1.46 37.1 1107 1647 DTTS18PCPBS14 14 1.53 38.8 1216 1810 DTTS18PCPBS16 16 1.60 40.6 1329 1977 DTTS18PCPBS17 17 1.68 42.6 1406 2092 DTTS18PCPBS19 19 1.68 42.6 1481 2204 DTTS18PCPBS20 20 1.82 46.1 1671 2486 DTTS18PCPBS24 24 1.99 50.6 1924 2864 Triads - 16 AWG, 26 Strands - Unarmored DTTS16PCP1 1 0.38 9.7 84 125 DTTS16PCP2 2 0.71 17.9 198 295 DTTS16PCP3 3 0.75 19.0 257 382 DTTS16PCP4 4 0.82 20.9 320 476 DTTS16PCP5 5 0.95 24.0 423 630 DTTS16PCP6 6 1.03 26.2 491 731 DTTS16PCP7 7 1.03 26.2 544 810 DTTS16PCP8 8 1.11 28.3 612 911 DTTS16PCP10 10 1.31 33.3 754 1122 DTTS16PCP12 12 1.36 34.4 867 1291 DTTS16PCP14 14 1.43 36.3 986 1468 DTTS16PCP16 16 1.51 38.4 1107 1647 DTTS16PCP17 17 1.59 40.5 1175 1748 DTTS16PCP19 19 1.59 40.5 1281 1906 DTTS16PCP20 20 1.68 42.6 1349 2007 DTTS16PCP24 24 1.94 49.3 1716 2554 Triads - 16 AWG, 26 Strands - Bronze Armored and Sheathed DTTS16PCPBS1 1 0.53 13.6 199 296 DTTS16PCPBS2 2 0.93 23.7 464 691 DTTS16PCPBS3 3 0.98 24.8 538 800 DTTS16PCPBS4 4 1.05 26.6 625 930 DTTS16PCPBS5 5 1.17 29.8 771 1147 DTTS16PCPBS6 6 1.26 31.9 867 1290 DTTS16PCPBS7 7 1.26 31.9 920 1369 DTTS16PCPBS8 8 1.34 34.1 1016 1513 DTTS16PCPBS10 10 1.54 39.1 1224 1822 DTTS16PCPBS12 12 1.58 40.2 1353 2013 DTTS16PCPBS14 14 1.66 42.1 1496 2227 DTTS16PCPBS16 16 1.80 45.8 1756 2613 DTTS16PCPBS17 17 1.89 47.9 1857 2764 DTTS16PCPBS19 19 1.89 47.9 1963 2921 DTTS16PCPBS20 20 1.97 50.0 2065 3073 DTTS16PCPBS24 24 2.23 56.7 2537 3776 Triads - 14 AWG, 41 Strands - Unarmored DTTS14PCP1 1 0.41 10.5 108 161 DTTS14PCP2 2 0.77 19.6 254 378 DTTS14PCP3 3 0.82 20.8 335 499 Continued on page 31

30 888.326.5174 • summit.com/marine Type P Signal & Instrumentation

Marine, Signal & Instrumentation, IS/OS Shielding, Pairs and Triads, XLPO/CP, 300-600/1000 Volts Continued from page 30

Summit # of Outside Diameter Weight Number Pairs (in.) (mm) (lbs./1000 ft.) (kg/km) DTTS14PCP4 4 0.95 24.0 461 686 DTTS14PCP5 5 1.04 26.3 552 821 DTTS14PCP6 6 1.13 28.7 644 958 DTTS14PCP7 7 1.13 28.7 718 1069 DTTS14PCP8 8 1.23 31.1 810 1206 DTTS14PCP10 10 1.45 36.7 1000 1487 DTTS14PCP12 12 1.49 38.0 1158 1723 DTTS14PCP14 14 1.58 40.0 1322 1968 DTTS14PCP16 16 1.67 42.3 1488 2214 DTTS14PCP17 17 1.83 46.4 1693 2519 DTTS14PCP19 19 1.83 46.4 1842 2742 DTTS14PCP20 20 1.92 48.8 1940 2887 DTTS14PCP24 24 2.14 54.4 2293 3412 Triads - 14 AWG, 41 Strands - Bronze Armored and Sheathed DTTS14PCPBS1 1 0.60 15.2 250 372 DTTS14PCPBS2 2 1.00 25.4 542 807 DTTS14PCPBS3 3 1.05 26.6 640 953 DTTS14PCPBS4 4 1.17 29.8 808 1203 DTTS14PCPBS5 5 1.26 32.1 929 1383 DTTS14PCPBS6 6 1.36 34.5 1053 1567 DTTS14PCPBS7 7 1.36 34.5 1128 1678 DTTS14PCPBS8 8 1.45 36.9 1252 1862 DTTS14PCPBS10 10 1.67 42.5 1515 2255 DTTS14PCPBS12 12 1.72 43.7 1690 2515 DTTS14PCPBS14 14 1.87 47.4 1998 2973 DTTS14PCPBS16 16 1.96 49.7 2199 3273 DTTS14PCPBS17 17 2.12 53.8 2468 3672 DTTS14PCPBS19 19 2.12 53.8 2617 3895 DTTS14PCPBS20 20 2.21 56.2 2753 4097 DTTS14PCPBS24 24 2.43 61.8 3194 4753

We Stock a Wide Variety of Cable Glands ATEX glands EX d,e both potted and unpotted. We also stock North American NEC glands potted and unpotted for hazardous and non-hazardous applications.

Learn more at summit.com/marine

Marine Division Toll-Free: 888.326.5174 [email protected]

888.326.5174 • summit.com/marine 31 Banding Tools and Supplies

Manual Cable Tools Hayata BT12000 QuikTie™ Hayata CT3 manual tool tensions and cuts steel ties. Offers close cut to the head when removing Battery Powered Cable Tool tail of stainless steel tie. Hayata’s most advanced battery operated cable tie installation tool. Built for speed and productivity, the Hayata BT12000 QuikTie™ delivers longer-lasting power in a more compact tool that’s 50 percent lighter than the previous model. The BT12000 is ideal for continuous overhead work as HYCT3 well as tight, hard-to-reach corners. • 4:1 productivity ratio advantage over standard tools • 12 volt tool • 20 clutch setting • Produces 220 pounds of torque, variable torque adjustment • Easy manual cut-off lever; no jagged edges because the tool cuts smoothly and close to the head every time • 30-minute rechargeable Lithium Ion battery • Delivers uniform tension for each installation, which means consistent tensioning for the entire job Hayata CT5 • Offers more control over tension vs. manual tools, Manual Cable Tool lowering risk of damage to the cable jacket HYBT12000 Manual tool with preset tension adjustment control, which allows for uniform tension Hayata BTX 6000 setting and automatic cutting on each bundle. Battery Powered Banding Tool Lightweight, one-hand operation. The first battery powered banding tool on the market, the Hayata BTX6000 is ideal for installing both coated and uncoated banding ranging in widths from 1/4" to 3/4". • 4:1 productivity ratio advantage over standard tools • 18 volt tool • Variable torque adjustment • Easy manual cut-off lever HYCT5 • 30-minute rechargeable battery (2 included) • Delivers uniform tension for each installation, which means consistant tensioning for the entire job • Offers more control over tension vs. manual tools, lowering risk of damage to the cable jacket HYBTX6000

Hayata Tough Tool Hayata Stainless Steel Coated Bands This tensioning tool with built-in cutter provides up to 2400 lbs of tension and can be Hayata Super Coated Banding provides the ultimate protection for any used on band, free-end clamps, fix band and bundling application where extreme weather, corrosion, salt spray, and coated band. Powder coat finish helps protect chemicals may be present. The coating provides an extra layer of protection the tool from corrosion. for the 316 Stainless Steel as well as a way to insulate the bundle and separate dissimilar metals. Hayata Super Coated Band is a must for offshore and marine applications.

Summit Thickness Width Weight Buckle Number in. mm in . mm lbs. kg Type HYCB3162 .048” 1.22 1/4” 6.35 3.00 1.40 HYTT2400 HYCB3163 .048” 1.22 3/8” 9.53 2.75 1.25 Wing Seals HYCB3164 .048” 1.22 1/2” 12.70 3.75 1.70 316SS HYCB3165 .048” 1.22 5/8” 15.88 4.40 2.00 HYCB3166 .048” 1.22 3/4” 19.00 5.20 2.36 Hayata Gorilla Tool Designed to be used with heavy duty band Hayata Tough Band or applications where 6000 lbs of torque may be required. Summit Thickness Width Weight Buckle Number in. mm in. mm lbs. kg Type HYSB3162 .020” 0.51 1/4” 6.35 1.7 0.77 HYSB3163 .025” 0.63 3/8” 9.53 3.2 1.45 HYSB3164 .030” 0.76 1/2” 12.7 5.1 2.31 Tiger Teeth HYSB3165 .030” 0.76 5/8” 15.88 6.4 2.9 316 SS HYSB3166 .030” 0.76 3/4” 19.05 7.7 3.5 HYGT6000 HYSB3165-020 .020” 0.51 5/8” 15.88 6.4 2.9 HYSB3165-015-2 .015” 0.38 5/8” 15.88 7.0 3.18

32 888.326.5174 • summit.com/marine Building Wire Copper

THHN/THWN/THWN-2, Copper Conductor, 600 Volts Application: Primarily used in conduit and cable trays Specifications:Meets ASTM specifications. UL-83, UL-1063, for services, feeders, and branch circuits in commercial or UL-1581. C22.2 No. 75-08. Federal Specification A-A-59544. industrial applications. Type THHN or T90 conductor suitable National ®. RoHS/REACH compliant. for use in dry locations, temperatures not to exceed 90°C. NEMA/WC 70. Type THWN-2 or TWN75 conductor suitable for use in wet Construction: Soft annealed copper conductors, unilay or dry locations. Temperatures not to exceed 90°C or 75°C compressed strand. Heat and moisture resistant PVC insulation. when exposed to oil. Temperatures not to exceed 105°C in Nylon (or UL- recognized equal) jacket. dry locations when rated AWM and used as appliance wiring material. Rated at 600 volts.

Size # of Insulation Thickness Jacket Thickness Nominal O.D. Weight Summit Number (AWG/kcmil) Strands (mils) (mils) (in.) (lbs./1000 ft.)

14SOL*** 14 Solid 15 4 0.102 16 12SOL*** 12 Solid 15 4 0.119 24 10SOL*** 10 Solid 20 4 0.150 38 14STR*** 14 19 15 4 0.110 16 12STR*** 12 19 15 4 0.129 24 10STR*** 10 19 20 4 0.163 38 8STR*** 8 19 30 5 0.213 63 6STR*** 6 19 30 5 0.250 95 4STR*** 4 19 40 6 0.320 152 3STR*** 3 19 40 6 0.360 189 2STR*** 2 19 40 6 0.379 234 1STR*** 1 19 50 7 0.436 299 1/0CUT 1/0 19 50 7 0.476 372 2/0CUT 2/0 19 50 7 0.520 462 3/0CUT 3/0 19 50 7 0.570 575 4/0CUT 4/0 19 50 7 0.626 718 250CUT 250 37 60 8 0.694 851 300CUT 300 37 60 8 0.747 1012 350CUT 350 37 60 8 0.797 1174 400CUT 400 37 60 8 0.842 1334 500CUT 500 37 60 8 0.925 1655 750CUT 750 61 70 9 1.170 2464 1000CUT 1000 61 70 9 1.320 3257 Pre-lubricated product (i.e. Southwire SIMpull®, Encore Super Slick™, etc.) is available on request.

*** Specify color with 3-letter color code. Example: 14SOLRED.

Black =BLA Green =GRE Blue =BLU Brown =BRO Purple =PUR Pink =PIN Green w/Yellow Stripe =G/Y

White =WHI Red =RED Orange =ORA Yellow =YEL Gray =GRA Tan =TAN

XHHW/XHHW-2, Copper Conductor, 600 Volts

Application: Primarily used in conduit or other recognized Construction: Soft annealed copper conductor. Abrasion, raceways for services, feeders,and branch circuit wiring. May be moisture, heat resistant XLP insulation. used in wet or dry locations at temperatures not to exceed 90°C. Rated at 600 volts. Specifications: UL-44. ASTM B-3, B-8. Federal Specification A-A-59544. ICEA S-95-658. NEMA/WC 70. IEEE 1202 (70,000 BTU/hr) Flame Test. CSA FT-4 Flame Test.

Size Insulation Thickness Nominal O.D. Weight Summit Number # of Strands (AWG/kcmil) (mils) (in.) (lbs./1000 ft.)

14XHHW*** 14 7 30 0.130 18 12XHHW*** 12 7 30 0.147 26 10XHHW*** 10 7 30 0.171 40 8XHHW*** 8 7 45 0.232 64 6XHHW*** 6 7 45 0.269 97 4XHHW*** 4 7 45 0.315 149 Pre-lubricated product (i.e. Southwire SIMpull®, Encore Super Slick™, etc.) is available on request.

Continued on page 34

888.326.5174 • summit.com/marine 33 Building Wire Copper

XHHW Copper Conductor, 600 Volts

Continued from page 33

Size Insulation Thickness Nominal O.D. Weight Summit Number # of Strands (AWG/kcmil) (mils) (in.) (lbs./1000 ft.)

2XHHW*** 2 7 45 0.373 230 1XHHW*** 1 19 55 0.432 291 1/0XHHW 1/0 19 55 0.472 363 2/0XHHW 2/0 19 55 0.516 452 3/0XHHW 3/0 19 55 0.566 564 4/0XHHW 4/0 19 55 0.622 704 250XHHW 250 37 65 0.688 834 300XHHW 300 37 65 0.741 995 350XHHW 350 37 65 0.791 1154 400XHHW 400 37 65 0.836 1312 500XHHW 500 37 65 0.919 1630 600XHHW 600 61 80 1.029 1966 700XHHW 700 61 80 1.098 2283 750XHHW 750 61 80 1.128 2441 1000XHHW 1000 61 80 1.280 3230 Pre-lubricated product (i.e. Southwire SIMpull®, Encore Super Slick™, etc.) is available on request.

*** Specify color with 3-letter color code. Example: 14XHHWRED.

Black =BLA Green =GRE Blue =BLU Brown =BRO Purple =PUR Pink =PIN

White =WHI Red =RED Orange =ORA Yellow =YEL Gray =GRA Tan =TAN

RHH/RHW/USE, Copper Conductors, 600 Volts

Application: Suitable for use as underground service entrance Construction: Soft annealed copper conductors. Abrasion, cable for direct burial at conductor temperatures not to exceed moisture, heat, and sunlight resistant XLP insulation. 90°C. Type RHH conductor temperatures shall not exceed 90°C in dry locations. When used as RHW-2 or USE-2, temperatures shall not exceed 90°C in wet or dry locations. Rated at 600 volts. Specifications:UL-44 (for RHH or RHW-2), UL-854 (for USE‑2). ASTM B-3, B-8, B-787 19. Federal Specification A-A-59544. National Electrical Code®. ICEA S-95-658. NEMA/WC70.

Size Insulation Thickness Nominal O.D. Weight Summit Number # of Strands (AWG/kcmil) (mils) (in.) (lbs./1000 ft.)

14USE 14 7 45 0.160 21 12USE 12 7 45 0.177 30 10USE 10 7 45 0.201 44 8USE 8 7 60 0.262 72 6USE 6 7 60 0.297 106 4USE 4 7 60 0.344 156 2USE 2 7 60 0.400 238 1USE 1 19 80 0.484 309 1/0USE 1/0 19 80 0.523 381 2/0USE 2/0 19 80 0.567 472 3/0USE 3/0 19 80 0.617 586 4/0USE 4/0 19 80 0.673 729 250USE 250 37 95 0.751 867 300USE 300 37 95 0.804 1029 350USE 350 37 95 0.854 1191 400USE 400 37 95 0.899 1352 500USE 500 37 95 0.983 1674 600USE 600 61 110 1.089 2012 700USE 700 61 110 1.158 2332 750USE 750 61 110 1.191 2492 800USE 800 61 110 1.223 2652 900USE 900 61 110 1.283 2970 1000USE 1000 61 110 1.340 3288

34 888.326.5174 • summit.com/marine Building Wire Copper

Underground Feeder Cable, Copper Conductors with Ground, 600 Volts

Application: Generally used as feeder to outside post lamps, Specifications: UL-83, UL-493. Federal Specification pumps, and other loads or apparatus fed from a distribution A-A-59544. National Electrical Code®. point in an existing building. May be used underground, Construction: Soft annealed copper conductors, solid or including direct burial. May be used for interior branch circuit compressed stranded. PVC insulation. Nylon jacket. wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors). Rated at 600 volts.

Summit Size # of Insulation Thickness Jacket Thickness # of Nominal Weight Number (AWG/kcmil) Conductors (mils) (mils) Strands O.D. (in.) (lbs./1000 ft.)

142UFWG 14 2 19 30 Solid .185 x .385 53 122UFWG 12 2 19 30 Solid .195 x .415 75 102UFWG 10 2 24 30 Solid .230 x .460 140 82UFWG 8 2 35 45 7 .320 x .620 213 62UFWG 6 2 35 45 7 .385 x .800 305 143UFWG 14 3 19 30 Solid .185 x .575 93 123UFWG 12 3 19 30 Solid .195 x .620 134 103UFWG 10 3 24 30 Solid .230 x .690 194 83UFWG 8 3 35 45 7 .320 x .990 330 63UFWG 6 3 35 45 7 .385 x 1.200 449

Around the Clock Convenience With Summit’s online services, you can: • Compare products and see available inventory • Get your account-specific pricing • Place orders any time, day or night • Track shipments and see proof of delivery • Access order history, invoices and credit memos

Learn more at summit.com/ebusiness

888.326.5174 • summit.com/marine 35 Cord Flexible

SJEOOW, 300 Volts

Application: Used as wiring for industrial machinery, heavy- for applications. Federal Specification J-C-580B. OSHA duty tools, motors, and temporary electrical power and lighting acceptable. RoHS compliant. National Electrical Code®. installations for construction sites. Flexible and durable in harsh ASTM B-174. environments where oil resistance and extended service life are Construction: Bare flexible copper conductors, Class K required. Temperature rating: -50°C to 105°C dry locations. stranding. Heat, moisture and oil resistant 105°C color-coded May be used in wet locations (even completely immersed in TPE insulation. Cabled with non-wicking polypropylene fillers, water) when exposed to oil or coolant at temperatures not with tissue-paper separator wrapped around assembly for greater than 60°C. Rated as hard-usage service cord. easier removal of jacket. Heat, moisture and oil resistant, Rated at 300 volts. flexible TPE jacket. Specifications: UL-62. CSA Standard 22.2 No. 49. CSA FT2. CSA Certified as Type SJTOOW (TPE). MSHA flame resistance

Size # of # of Insulation Jacket O.D. Weight Summit Number (AWG/kcmil) Conductors Strands Thickness (in.) Thickness (in) (in.) (lbs./1000 ft.) SJEOOW182 18 2 16 0.030 0.030 0.290 36 SJEOOW183 18 3 16 0.030 0.030 0.305 47 SJEOOW184 18 4 16 0.030 0.030 0.330 58 SJEOOW162 16 2 26 0.030 0.030 0.315 46 SJEOOW163 16 3 26 0.030 0.030 0.330 61 SJEOOW164 16 4 26 0.030 0.030 0.360 75 SJEOOW142 14 2 41 0.030 0.030 0.345 80 SJEOOW143 14 3 41 0.030 0.030 0.365 109 SJEOOW144 14 4 41 0.030 0.030 0.400 139 SJEOOW122 12 2 65 0.045 0.045 0.415 92 SJEOOW123 12 3 65 0.045 0.045 0.435 121 SJEOOW124 12 4 65 0.045 0.045 0.480 155 SJEOOW102 10 2 104 0.045 0.060 0.555 150 SJEOOW103 10 3 104 0.045 0.060 0.590 207 SJEOOW104 10 4 104 0.045 0.060 0.645 262

SJOOW, 300 Volts

Application: Used as wiring for portable tools, portable Specification J-C-580B. OSHA acceptable. RoHS compliant. appliances, equipment, small motors and associated machinery. National Electrical Code®. ASTM B-174. UL Listed and CSA Certified for indoor/outdoor use. Oil and Construction: Bare flexible copper conductors, Class K water resistant. High flexibility. Rated as hard usage service stranding. Heat, moisture and oil resistant EPDM rubber cord. Temperature rating: -40°C to 90°C. Rated at 300 volts. insulation. Cabled with wax paper fillers, with tissue-paper Specifications: UL-62. CSA Standard 22.2 No. 49. MSHA flame separator wrapped around assembly for easier removal of resistance for mining applications (P-136-MSHA). Federal jacket. Heat, moisture and oil resistant, flexible CPE jacket.

Size # of # of Insulation Jacket O.D. Weight Summit Number (AWG/kcmil) Conductors Strands Thickness (in.) Thickness (in.) (in.) (lbs./1000 ft.) SJOOW182 18 2 30 0.030 0.030 0.290 48 SJOOW183 18 3 30 0.030 0.030 0.310 59 SJOOW184 18 4 30 0.030 0.030 0.335 72 SJOOW162 16 2 30 0.030 0.030 0.315 61 SJOOW163 16 3 30 0.030 0.030 0.335 75 SJOOW164 16 4 30 0.030 0.030 0.360 92 SJOOW142 14 2 30 0.030 0.030 0.345 79 SJOOW143 14 3 30 0.030 0.030 0.370 98 SJOOW144 14 4 30 0.030 0.030 0.405 121 SJOOW122 12 2 30 0.030 0.045 0.415 123 SJOOW123 12 3 30 0.030 0.045 0.435 144 SJOOW124 12 4 30 0.030 0.045 0.475 180 SJOOW102 10 2 30 0.045 0.060 0.555 18 SJOOW103 10 3 30 0.045 0.060 0.580 24 SJOOW104 10 4 30 0.045 0.060 0.640 30

36 888.326.5174 • summit.com/marine Cord Flexible Portable Cord

SOOW, 600 Volts

Application: Designed for extra hard usage on industrial FT-1 and FT-2 Flame Test. RoHS compliant. National equipment, heavy tools, battery chargers, portable lights Electrical Code®. welding leads, marine dockside power, power extensions and Construction: Bare flexible copper conductors, Class K mining applications. Also may be used for special applications stranding. Heat, moisture and oil resistant EPDM rubber outlined in NFPA 70 for Class I Division1 and 2, Class II insulation. Cabled with wax paper fillers, with tissue-paper Division 1 and 2 locations. For indoor/outdoor use, and for separator wrapped around assembly for easier removal of continuous submersion in water. Temperature rating: -40°C to jacket. Heat, moisture and oil resistant, flexible CPE jacket. 90°C. Rated at 600 volts. Also available in yellow. Contact Summit for details. Specifications: UL-62. CSA Standard C22.2 No. 49. OSHA acceptable. MSHA Listed. MSHA Flame Test (P-136-MSHA).

Size # of # of Insulation Jacket O.D. Weight Summit Number (AWG/kcmil) Conductors Strands Thickness (in.) Thickness (in.) (in.) (lbs./1000 ft.)

SOOW182 18 2 16 0.030 0.060 0.340 70 SOOW183 18 3 16 0.030 0.060 0.360 85 SOOW184 18 4 16 0.030 0.060 0.390 100 SOOW185 18 5 16 0.030 0.060 0.460 130 SOOW186 18 6 16 0.030 0.060 0.490 150 SOOW187 18 7 16 0.030 0.060 0.500 160 SOOW188 18 8 16 0.030 0.060 0.530 170 SOOW1810 18 10 16 0.030 0.060 0.600 215 SOOW1812 18 12 16 0.030 0.060 0.600 245 SOOW1814 18 14 16 0.030 0.060 0.660 265 SOOW1816 18 16 16 0.030 0.060 0.700 310 SOOW1818 18 18 16 0.030 0.060 0.760 340 SOOW1820 18 20 16 0.030 0.060 0.790 375 SOOW1824 18 24 16 0.030 0.060 0.900 450 SOOW1830 18 30 16 0.030 0.060 0.920 520 SOOW1836 18 36 16 0.030 0.060 1.050 600 SOOW162 16 2 26 0.030 0.060 0.370 80 SOOW163 16 3 26 0.030 0.060 0.390 105 SOOW164 16 4 26 0.030 0.060 0.420 120 SOOW165 16 5 26 0.030 0.060 0.490 160 SOOW166 16 6 26 0.030 0.060 0.520 175 SOOW167 16 7 26 0.030 0.060 0.550 195 SOOW168 16 8 26 0.030 0.060 0.570 220 SOOW169 16 9 26 0.030 0.060 0.620 250 SOOW1610 16 10 26 0.030 0.060 0.650 280 SOOW1612 16 12 26 0.030 0.060 0.690 325 SOOW1614 16 14 26 0.030 0.060 0.750 355 SOOW1616 16 16 26 0.030 0.060 0.760 380 SOOW1618 16 18 26 0.030 0.060 0.790 425 SOOW1620 16 20 26 0.030 0.060 0.810 480 SOOW1624 16 24 26 0.030 0.060 0.920 550 SOOW1630 16 30 26 0.030 0.060 1.050 715 SOOW1636 16 36 26 0.030 0.060 1.120 800 SOOW1637 16 37 26 0.030 0.060 1.180 815 SOOW1640 16 40 26 0.030 0.060 1.240 850 SOOW142 14 2 41 0.045 0.095 0.500 135 SOOW143 14 3 41 0.045 0.095 0.530 170 SOOW144 14 4 41 0.045 0.095 0.570 205 SOOW145 14 5 41 0.045 0.095 0.650 275 SOOW146 14 6 41 0.045 0.095 0.710 315 SOOW147 14 7 41 0.045 0.095 0.710 345 SOOW148 14 8 41 0.045 0.095 0.760 385 SOOW149 14 9 41 0.045 0.095 0.830 410 SOOW1410 14 10 41 0.045 0.095 0.830 430 SOOW1412 14 12 41 0.045 0.095 0.870 485 SOOW1414 14 14 41 0.045 0.095 1.000 590

Continued on page 38

888.326.5174 • summit.com/marine 37 Cord Flexible Portable Cord

SOOW, 600 Volts

Continued from page 37

Size # of # of Insulation Jacket O.D. Weight Summit Number (AWG/kcmil) Conductors Strands Thickness (in.) Thickness (in.) (in.) (lbs./1000 ft.)

SOOW1416 14 16 41 0.045 0.095 1.030 665 SOOW1418 14 18 41 0.045 0.095 1.100 710 SOOW1420 14 20 41 0.045 0.095 1.150 780 SOOW1424 14 24 41 0.045 0.095 1.260 985 SOOW1430 14 30 41 0.045 0.095 1.340 1130 SOOW1437 14 37 41 0.045 0.095 1.480 1330 SOOW122 12 2 65 0.045 0.095 0.570 195 SOOW123 12 3 65 0.045 0.095 0.600 220 SOOW124 12 4 65 0.045 0.095 0.650 270 SOOW125 12 5 65 0.045 0.095 0.710 330 SOOW127 12 7 65 0.045 0.095 0.770 415 SOOW128 12 8 65 0.045 0.095 0.820 470 SOOW129 12 9 65 0.045 0.095 0.900 515 SOOW1210 12 10 65 0.045 0.095 1.000 580 SOOW1212 12 12 65 0.045 0.095 1.010 650 SOOW1214 12 14 65 0.045 0.095 1.080 740 SOOW1216 12 16 65 0.045 0.095 1.130 835 SOOW1220 12 20 65 0.045 0.095 1.170 990 SOOW1224 12 24 65 0.045 0.095 1.400 1240 SOOW1230 12 30 65 0.045 0.095 1.500 1415 SOOW1236 12 36 65 0.045 0.095 1.650 1670 SOOW1240 12 40 65 0.045 0.095 1.690 1830 SOOW102 10 2 104 0.045 0.095 0.620 215 SOOW103 10 3 104 0.045 0.095 0.660 290 SOOW104 10 4 104 0.045 0.095 0.710 350 SOOW105 10 5 104 0.045 0.095 0.770 465 SOOW106 10 6 104 0.045 0.095 0.870 490 SOOW107 10 7 104 0.045 0.095 0.890 500 SOOW108 10 8 104 0.045 0.095 0.940 625 SOOW1010 10 10 104 0.045 0.095 1.020 765 SOOW1012 10 12 104 0.045 0.095 1.070 865 SOOW1016 10 16 104 0.045 0.095 1.230 1150 SOOW1020 10 20 104 0.045 0.095 1.260 1445 SOOW83 8 3 65 0.060 0.110 0.700 375 SOOW84 8 4 65 0.060 0.125 0.790 480 SOOW85 8 5 65 0.060 0.125 0.830 570 SOOW63 6 3 133 0.060 0.125 0.780 510 SOOW64 6 4 133 0.060 0.140 0.850 615 SOOW65 6 5 133 0.060 0.140 0.950 810 SOOW43 4 3 133 0.060 0.140 0.930 680 SOOW44 4 4 133 0.060 0.155 1.000 845 SOOW45 4 5 133 0.060 0.155 1.010 1140 SOOW23 2 3 168 0.060 0.155 1.060 985 SOOW24 2 4 168 0.060 0.170 1.100 1245 SOOW25 2 5 168 0.060 0.170 1.300 1650

38 888.326.5174 • summit.com/marine Cord Flexible Portable Cord, Portable Power

SEOOW, 600 Volts

Application: Used as wiring for industrial machinery, heavy- Specifications:UL-62 approved. Meets CSA Standard 22.2 No. 49. duty tools, motors, and temporary electrical power and lighting MSHA Listed. Federal Specification J-C-580B. OSHA acceptable. installations for construction sites. Flexible and durable in harsh RoHS compliant. National Electrical Code®. ASTM B-174. environments where oil resistance and extended service life are Construction: Bare flexible copper conductors, Class K stranding. required. Temperature rating: -50°C to 105°C dry locations. May be Heat, moisture and oil resistant 105°C color-coded TPE insulation. used in wet locations (even completely immersed in water) when Cabled with non-wicking polypropylene fillers, with tissue-paper exposed to oil or coolant at temperatures not greater than 60°C. separator wrapped around assembly for easier removal of jacket. Rated as hard-usage service cord. Heat, moisture and oil resistant, flexible TPE jacket.

Size # of # of Insulation Jacket O.D. Weight Summit Number (AWG/kcmil) Conductors Strands Thickness (in.) Thickness (in.) (in.) (lbs./1000 ft.) SEOOW182 18 2 16 0.030 0.060 0.340 57 SEOOW183 18 3 16 0.030 0.060 0.360 69 SEOOW184 18 4 16 0.030 0.060 0.390 78 SEOOW162 16 2 26 0.030 0.060 0.370 69 SEOOW163 16 3 26 0.030 0.060 0.390 80 SEOOW164 16 4 26 0.030 0.060 0.420 96 SEOOW142 14 2 41 0.045 0.080 0.500 124 SEOOW143 14 3 41 0.045 0.080 0.530 149 SEOOW144 14 4 41 0.045 0.080 0.570 180 SEOOW122 12 2 65 0.045 0.095 0.570 152 SEOOW123 12 3 65 0.045 0.095 0.600 197 SEOOW124 12 4 65 0.045 0.095 0.640 240 SEOOW102 10 2 104 0.045 0.095 0.620 193 SEOOW103 10 3 104 0.045 0.095 0.660 257 SEOOW104 10 4 104 0.045 0.095 0.700 313 SEOOW82 8 2 96 0.050 0.060 0.660 233 SEOOW83 8 3 96 0.050 0.060 0.700 327 SEOOW84 8 4 96 0.050 0.060 0.780 420 SEOOW85 8 5 96 0.050 0.060 0.780 420 SEOOW62 6 2 96 0.050 0.060 0.740 302 SEOOW63 6 3 96 0.050 0.060 0.810 458 SEOOW64 6 4 96 0.050 0.080 0.880 599 SEOOW65 6 5 96 0.050 0.080 0.880 599 SEOOW42 4 2 96 0.050 0.080 0.900 464 SEOOW43 4 3 96 0.050 0.080 0.980 667 SEOOW44 4 4 96 0.050 0.080 1.090 865 SEOOW45 4 5 96 0.050 0.080 1.090 865 SEOOW22 2 2 96 0.050 0.080 1.090 715 SEOOW23 2 3 119 0.050 0.080 1.150 971 SEOOW24 2 4 119 0.050 0.080 1.260 1225 SEOOW25 2 5 119 0.050 0.080 1.260 1225

Bus Drop Cable, 600 Volts

Application: For use in indoor or outdoor applications for Specifications: UL Listed. OSHA acceptable. RoHS compliant. connection of stationary or portable equipment to facilitate ASTM B-8, B-174. relocation of equipment.Used in wet or dry locations. Construction: Annealed bare copper conductors, stranded. Resistant to oils, lubricants, acids, alkalies, ozone, water and PVC insulation. Conductors and ground , along with abrasion. Temperature rating: -20°C to 75°C (14-8 AWG), paper or polypropylene fillers, cabled for flexibility, wrapped 60°C (6-2 AWG). Rated at 600 volts. with mylar separator to aid strippability. PVC jacket.

Size Ground # of Insulation Jacket Summit # of # of Nominal O.D. Weight (AWG/ Wire Size Ground Thickness Thickness Number Conductors Strands (in.) (lbs./1000 ft.) kcmil) (AWG) Wires (mils) (mils) BUSDROP143 14 3 19 18 3 30 45 0.379 107 BUSDROP123 12 3 19 16 3 30 45 0.420 149 BUSDROP103 10 3 19 14 3 30 45 0.470 211 BUSDROP83 8 3 19 14 3 45 60 0.630 328 BUSDROP63 6 3 19 14 3 60 60 0.794 486 BUSDROP43 4 3 19 12 3 60 80 0.939 733 BUSDROP23 2 3 19 12 3 60 80 1.071 1019

888.326.5174 • summit.com/marine 39 Cord Portable Power Hook-Up Wire, MTW/TEW or AWM, 600 Volts

Application: Used for machine tool wiring, and internal wiring Specifications:ASTM B-174 (sizes 18-10 AWG), ASTM B-787 of appliances, including wiring for refrigeration equipment, (sizes 8 - 2 AWG). UL-1063, UL-1015 and Subject 758. CSA air-conditioning equipment, control wiring of machine tools, C22.2 No. 127-95 and No. 210.2-95. Federal and Military automatic washers, etc. Machine tool wire rated at 600 volts. Specification J-C-30B. National Electrical Code NFPA 70 and 79. Temperature rating: -40°C to 90°C (ampacity limited to 75°C). OSHA acceptable. RoHS compliant. UL VW-1 and CSA FT-1. Type TEW rating permits use in (i) dry locations not to exceed Construction: Bare flexible copper conductors, Class K 105°C; or (ii) wet locations or other applicable locations when stranding (sizes 18-10 AWG), and combination unilay stranding exposed to oil or coolant at temperatures not to exceed 60°C. (sizes 8-2 AWG). Heat and moisture resistant PVC insulation. When used as AWM, intended uses limited to dry locations at temperatures not to exceed 105°C (applicable to both UL and CSA ratings).

Insulation Thickness Summit Number Size (AWG/kcmil) # of Strands O.D. (in.) Weight (lbs./1000 ft.) (mils) MTW18 18 16 30 0.110 8 MTW16 16 26 30 0.123 11 MTW14 14 41 30 0.133 18 MTW12 12 65 30 0.151 25 MTW10 10 104 30 0.205 40 MTW8 8 19 45 0.234 67 MTW6 6 19 60 0.300 100 MTW4 4 19 60 0.348 150 MTW2 2 19 60 0.404 230

Welding Cable, Single Copper Conductor, 600 Volts

Application: Used in welding applications for connections Specifications: ASTM B-3, B-172. between electrode holder and clamp, to arc welder, bus, welding Construction: Bare flexible copper conductor, Class K box or transformer. For use in industrial applications such as stranding. EPDM rubber insulation. shipyards, mines and construction sites. Flexible and durable in harsh environments. Temperature rating: -40°C to 90°C. Rated at 600 volts.

Summit Number Size (AWG/kcmil) # of Strands Nominal O.D. (in.) Weight (lbs./1000 ft.)

WELD8 8 161 0.730 79 WELD6 6 260 0.730 142 WELD4 4 374 0.730 180 WELD2 2 625 0.730 270 WELD1 1 778 0.730 325 WELD1/0 1/0 990 0.870 425 WELD2/0 2/0 1251 0.870 480 WELD3/0 3/0 1586 1.050 650 WELD4/0 4/0 2005 1.050 820 WELD250 250 2496 1.190 965 WELD350 350 3432 1.200 1345 WELD500 500 5054 1.200 1950

Diesel Locomotive, Single Copper Conductor (RHH/RHW), 2kV

Application: Used in diesel electric locomotive and car IEEE 383 (70,000 BTU/hr) Flame Test. MSHA approved. ICEA equipment, mining, general construction, temporary power S-95-658, NEMA WC-70, Association of American Railroads supply motor lead, and when CT rated. Flexible and (AAR). ASTM B-33, B-172, B-174. durable in harsh environments. Temperature rating: 90°C. Construction: Tin-coated soft annealed copper conductor. EPR Rated at 2,000 volts. rubber insulation. CPE jacket. Specifications: UL-1658 Vertical Cable Tray Flame Test.

Size # of Insulation Jacket Area O.D. Weight Summit Number (AWG/kcmil) Strands Thickness (mils) Thickness (mils) (circular mils) (in.) (lbs./1000 ft.) DLO2KV14 14 19 47 20 3831 0.200 30 DLO2KV12 12 19 47 20 6088 0.220 40

Continued on page 41

40 888.326.5174 • summit.com/marine Cord Portable Power

Diesel Locomotive, Single Copper Conductor (RHH/RHW), 2kV

Continued from page 40

Size # of Insulation Jacket Area O.D. Weight Summit Number (AWG/kcmil) Strands Thickness (mils) Thickness (mils) (circular mils) (in.) (lbs./1000 ft.) DLO2KV10 10 27 47 20 10910 0.250 55 DLO2KV08 8 37 55 20 14950 0.280 75 DLO2KV06 6 61 62 31 24640 0.360 125 DLO2KV04 4 105 62 31 42420 0.450 200 DLO2KV02 2 147 62 31 60600 0.490 265 DLO2KV1 1 224 78 47 90900 0.620 415 DLO2KV1/0 1/0 273 78 47 111100 0.660 490 DLO2KV2/0 2/0 323 78 47 131300 0.700 560 DLO2KV3/0 3/0 456 78 47 181800 0.780 755 DLO2KV4/0 4/0 551 78 47 222200 0.840 895 DLO2KV262 262 646 94 65 262600 0.950 1085 DLO2KV313 313 777 94 65 313100 1.020 1255 DLO2KV373 373 925 94 65 373700 1.080 1485 DLO2KV444 444 1100 94 65 444400 1.150 1745 DLO2KV535 535 1332 109 65 535300 1.260 2090 DLO2KV646 646 1591 109 65 646400 1.350 2470 DLO2KV777 777 1924 109 65 777700 1.450 2910 DLO2KV929 929 2318 109 65 929200 1.590 3515 DLO2KV1111 1111 2745 125 65 1111000 1.690 4150

The Tool Every Electrician Needs. Formulas, tables, charts and diagrams that you can use every day on every job. Now updated for the 2011 NEC®.

Learn more at summit.com/refbook

888.326.5174 • summit.com/marine 41 Cord Portable Power Type G & G-GC Round Power Cable with Ground, 2kV

Application: Used in industrial and light- to medium-duty Specifications: UL and c(UL) Listed. UL-1650 and FT-5 Flame mining applications, heavy-duty service as power supply cable, Test. MSHA approved. RoHS compliant. power cable for mobile and portable electrical equipment. Construction: Annealed copper conductors, stranded. EPDM Temperature rating: -40°C to 90°C. 90°C dry locations, 75°C insulation. CPE rubber jacket. wet locations. May be used in marina (wet) locations. Suitable for use on three-phase AC systems where 3 or 4 conductors are needed and grounding is required. Flexible and resistant to oils, solvents, ozone, aging and abrasion. Rated at 2,000 volts.

Size Ground Ground Conductor Insulation Weight Summit # of O.D. (AWG/ Conductors* Check Size Thickness Ampacity (lbs./ Number Strands # of Size (in.) kcmil) (AWG) Conductors (AWG) (in.) 1000 ft.) G2KV83GGC 8 3 10 49 2 10 0.060 1.000 65 665 G2KV63GGC 6 3 10 49 2 10 0.060 1.050 87 830 G2KV43GGC 4 3 8 105 2 8 0.060 1.750 114 1145 G2KV23GGC 2 3 7 168 2 7 0.060 1.335 152 1485 G2KV13GGC 1 3 6 420 2 6 0.080 1.485 177 2100 G2KV1/03GGC 1/0 3 5 259 2 5 0.080 1.615 205 2550 G2KV2/03GGC 2/0 3 4 259 2 4 0.080 1.690 237 3020 G2KV3/03GGC 3/0 3 3 420 2 3 0.080 1.800 274 3660 G2KV4/03GGC 4/0 3 2 516 2 2 0.080 1.970 316 4410 G2KV2503GGC 250 3 1 608 2 2 0.095 2.240 352 6060 G2KV3503GGC 350 3 1/0 855 2 1/0 0.095 2.480 433 7400 G2KV5003GGC 500 3 3/0 1235 2 2/0 0.095 2.880 536 10100 G2KV84GC 8 4 - 71 4 12 0.060 1.055 52 635 G2KV64GC 6 4 - 49 4 12 0.060 1.140 70 900 G2KV44GC 4 4 - 105 4 10 0.060 1.250 91 1280 G2KV24GC 2 4 - 168 4 9 0.060 1.465 122 2000 G2KV14GC 1 4 - 210 4 8 0.080 1.665 142 2660 G2KV1/04GC 1/0 4 - 259 4 7 0.080 1.765 164 3140 G2KV2/04GC 2/0 4 - 259 4 6 0.080 1.875 190 3780 G2KV3/04GC 3/0 4 - 420 4 5 0.080 2.000 219 4800 G2KV4/04GC 4/0 4 - 516 4 4 0.080 2.175 253 5520 G2KV2504GC 250 4 - 608 4 2 0.095 2.555 281 6020 G2KV3504GC 350 4 - 855 4 1/0 0.095 2.700 346 7198 G2KV5004GC 500 4 - 1235 4 2/0 0.095 3.260 429 10822 *3 Conductor with Ground Check

Type W Portable Power Cable, 2kV

Application: For use in industrial and light-to-medium mining ICEA S-75-381. MSHA accepted, P-136-135, LR65300. ASTM applications, heavy-duty service, and temporary as power B-172. CSA or c(UL) certified as applicable. RoHS Compliant. supply cables. Also used for motor, battery and generator leads, Construction: Annealed copper conductors, stranded. EP mobile and portable electrical equipment. Temperature rating: rubber insulation. CPE rubber jacket. -40°C to 90°C. Rated at 2,000 volts. Specifications: UL Listed as Type RHH or RHW-2, and UL- 1650 as Type W. NEMA WC-58. FT-5 Flame Test.

Nominal Nominal Summit # of Size Weight # of Strands Insulation Thickness Cable O.D. Number Conductors (AWG/kcmil) (lbs./1000ft.) (in.) (mm) (in.) (mm) W8 1 8 168 0.060 1.520 0.490 11.180 160 W6 1 6 266 0.060 1.520 0.535 13.590 220 W4 1 4 420 0.060 1.520 0.595 15.110 290 W2 1 2 651 0.060 1.520 0.645 16.380 395 W1 1 1 840 0.080 2.030 0.695 17.650 490 W1/0 1 1/0 1064 0.080 2.030 0.770 19.560 575 W2/0 1 2/0 1311 0.080 2.030 0.800 20.320 700 *UL listed only. Multiconductor cables are UL and C(UL) unless marked.

Continued on page 43

42 888.326.5174 • summit.com/marine Cord Portable Power

Type W Portable Power Cable, 2kV

Continued from page 42

Nominal Nominal Summit # of Size Weight # of Strands Insulation Thickness Cable O.D. Number Conductors (AWG/kcmil) (lbs./1000ft.) (in.) (mm) (in.) (mm) W3/0 1 3/0 1653 0.080 2.030 0.860 21.840 820 W4/0 1 4/0 2090 0.080 2.030 0.925 23.490 1000 W250 1 250 627 0.095 2.410 1.045 26.540 1170 W350 1 350 855 0.095 2.410 1.145 29.100 1520 W500 1 500 1235 0.095 2.410 1.310 33.280 2090 W82 2 8 71 0.060 1.520 0.820 20.830 365 W62 2 6 49 0.060 1.520 0.930 23.620 515 W42 2 4 105 0.060 1.520 1.050 26.670 730 W22 2 2 168 0.080 1.520 1.245 31.620 1000 W12 2 1 210 0.080 2.030 1.420 36.070 1490 W1/02 2 1/0 259 0.080 2.030 1.515 38.480 1710 W2/02 2 2/0 259 0.080 2.030 1.575 40.000 1880 W3/02 2 3/0 420 0.080 2.030 1.685 42.800 2420 W4/02 2 4/0 516 0.080 2.030 1.845 46.860 2940 W83 3 8 71 0.060 1.520 0.930 23.620 525 W63 3 6 49 0.060 1.520 1.015 25.780 660 W43 3 4 105 0.060 1.520 1.130 28.700 900 W23 3 2 168 0.080 1.520 1.320 33.530 1300 W13 3 1 210 0.080 2.030 1.475 37.470 1600 W1/03 3 1/0 259 0.080 2.030 1.605 40.770 2280 W2/03 3 2/0 259 0.080 2.030 1.680 42.670 2680 W3/03 3 3/0 420 0.080 2.030 1.825 46.360 3220 W4/03 3 4/0* 516 0.080 2.030 1.950 49.530 3900 W2503 3 250* 608 0.095 2.410 2.275 57.780 5070 W3503 3 350* 855 0.095 2.410 2.425 61.590 6570 W5003 3 500* 1235 0.095 2.410 2.845 72.260 8700 W84 4 8 71 0.060 1.520 1.010 25.650 620 W64 4 6 49 0.060 1.520 1.105 28.070 825 W44 4 4 105 0.060 1.520 1.245 31.620 1175 W24 4 2 168 0.060 1.520 1.465 37.210 1650 W14 4 1 210 0.080 2.030 1.625 41.270 2450 W1/04 4 1/0 259 0.080 2.030 1.755 44.580 2570 W2/04 4 2/0 259 0.080 2.030 1.875 47.620 3450 W3/04 4 3/0* 420 0.080 2.030 1.905 48.390 4050 W4/04 4 4/0* 516 0.080 2.030 2.175 55.240 4970 W85 5 8 71 0.060 1.520 1.070 27.180 710 W65 5 6 49 0.060 1.520 1.210 30.730 1010 W45 5 4 105 0.060 1.520 1.400 35.560 1400 W25 5 2 168 0.060 1.520 1.605 40.770 2340 W15 5 1 210 0.080 2.030 1.890 48.010 3040 W1/05 5 1/0 259 0.080 2.030 2.010 51.050 3460 W2/05 5 2/0* 259 0.080 2.030 2.075 52.700 4180 W3/05 5 3/0* 420 0.080 2.030 2.260 55.500 4900 W4/05 5 4/0* 516 0.080 2.030 2.425 61.590 5980 *UL listed only. Multiconductor cables are UL and C(UL) unless marked.

888.326.5174 • summit.com/marine 43 Cord Cord Sets

SJEOW Extension Cord, Single Tap

Application: General purpose extension cord for indoor use. Construction: Clear PVC plug and connector with neon power Rated for hard usage. Temperature rating -50°C to 90°C. indicator lamp in the cord connector. TPE jacket. Rated at 125 volts. Specifications: UL Listed for outdoor use. NEMA 5-15. National Electrical Code®. RoHS compliant.

Summit Number Size (AWG/kcmil) # of Conductors Nominal O.D. (in.) Amps Length (ft.)

163EXT25 16 3 0.316 13 25 163EXT50 16 3 0.316 13 50 163EXT100 16 3 0.316 10 100 143EXT25 14 3 0.352 15 25 143EXT50 14 3 0.352 15 50 143EXT100 14 3 0.352 13 100 123EXT25 12 3 0.420 15 25 123EXT50 12 3 0.420 15 50 123EXT100 12 3 0.420 15 100 103EXT25 10 3 0.567 15 25 103EXT50 10 3 0.567 15 50 103EXT100 10 3 0.567 15 100

SEOW Extension Cord, Triple Tap

Application: Three-receptacle adapter cord set rated for Construction: Clear PVC plug and connector with neon power extra hard usage. Temperature rating -55°C to 90°C. indicator lamp in cord connector. TPE jacket. Rated at 125 volts. Specifications:UL Listed. NEMA 5-15. National Electrical Code®.

Summit Number Size (AWG/kcmil) # of Conductors Nominal O.D. (in.) Amps Length (ft.)

123EXTTT6 12 3 0.420 15 6 123EXTTT25 12 3 0.420 15 25 123EXTTT50 12 3 0.420 15 50 123EXTTT100 12 3 0.420 15 100

SJEOW Extension Cord, Quad Tap

Application: General purpose extension cord. Rated for hard Construction: Clear PVC plug and connector with neon power usage. Temperature rating -50°C to 90°C. Rated at 125 volts. indicator lamp in the cord connector. TPE jacket. Specifications: UL Listed. NEMA 5-15. National Electrical Code®. RoHS compliant.

Summit Number Size (AWG/kcmil) # of Conductors Nominal O.D. (in.) Amps Length (ft.)

123EXTQT6 12 3 0.420 15 6 123EXTQT25 12 3 0.420 15 25 123EXTQT50 12 3 0.420 15 50 123EXTQT100 12 3 0.420 15 100

44 888.326.5174 • summit.com/marine Impervious Continuously Welded

Impervious Continuously Welded (ICW) Armored Instrumentation Cable, Individual and Overall Shielded, 600 Volt Applications: For use where 600 volt instrumentation cables UL File # E69797 UL listed marine shipboard, UL File #E85994 with individually shielded pairs or triads and an overall shield American Bureau of Shipping (ABS). Rated for 600 volts, cable are required. Provide liability against physical damage for use tray use and direct burial. in instrumentation and process control applications where Construction: Conductors are bare annealed copper per shielding against both external EMI and EMI between groups is ASTM B3 Class B stranding per ASTM B8. Flame-retardant required. For use in Class1 remote-control and signal circuits in polyvinyl chloride(PVC) insulation and nylon covering rated accordance with NEC Article 725. Recognized for use in Class I, 90°C per UL Standard 83. Color-coded per ICEA Method 1 II and III, Divisions 1 and 2; or Class I, Zones1 and 2 hazardous (pairs – black and white; triads – black,white and red). Each locations per NEC Articles 501, 502, 503 and 505 Installed conductor in each pair or triad is printed alpha numerically indoors or outdoors, in wet or dry locations, in a raceway, as for easy identification. Twisted pairs have aluminum/polyester aerial cable on a messenger, in cable trays,or for direct burial. tape shielding which provides 100% coverage. Stranded, Recognized for use on fixed or floating offshore petroleum tinned copper drain wires are two sizes smaller than insulated facilities as recommended by the American Petroleum Institute. conductors. Individually shielded pairs or triads are cabled Specifications: UL 83 thermoplastic insulated wire and cables. together with a left-hand lay. Stranded, tinned copper UL 1569 metal clad cables UL 2225 cables and cable fittings for drain wire in the overall shield is the same size as insulated use in hazardous locations. UL 1309/CSA C22.2 No. 245 marine conductors. The inner jacket is flame-retardant PVC per UL shipboard cable. Flame tests ICEA T-29-520 (210,000 BTU/hr), Standard 1569, black. Low temperature performance meets IEEE 383 (70,000 BTU/hr), CSA FT4, IEEE 1202 (70,000 BTU/ ASTM D746 brittleness temperature at or below -40°C. Nylon hr), UL 1581 (70,000 BTU/hr), IEC 60332-3 Cat. A. Complies rip cord to facilitate jacket removal. with UL Type MC-HL, CT USE, SUN RES,DIR BUR, -40°C,

Conductor Inner Nominal Nominal Overall Nominal Cross Insulation Weight Summit # of Jacket Core Armor Jacket Overall Section Size Thickness (lbs./ Number Pairs/ Thickness O.D. O.D. Thickness O.D. Area (AWG) (mils) 1000ft.) Triads (mils) (in.) (in.) (mils) (in.) (sq. in.) Conductor Pairs ICW182SPOS 18 2 19 40 0.41 0.59 50 0.70 0.39 222 ICW184SPOS 18 4 19 40 0.48 0.65 50 0.75 0.45 268 ICW188SPOS 18 8 19 50 0.60 0.82 50 0.92 0.67 420 ICW1812SPOS 18 12 19 50 0.78 1.00 50 1.10 0.96 560 ICW1816SPOS 18 16 19 50 0.81 1.12 50 1.23 1.20 706 ICW1824SPOS 18 24 19 50 1.08 1.39 50 1.49 1.77 969 ICW162SPOS 16 2 19 40 0.45 0.67 50 0.78 0.48 239 ICW164SPOS 16 4 19 50 0.56 0.80 50 0.91 0.66 342 ICW166SPOS 16 6 19 50 0.66 0.89 50 1.00 0.80 429 ICW168SPOS 16 8 19 50 0.70 0.93 50 1.04 0.86 502 ICW1610SPOS 16 10 19 50 0.79 1.06 50 1.17 1.09 613 ICW1612SPOS 16 12 19 50 0.85 1.11 50 1.22 1.18 687 ICW1616SPOS 16 16 19 50 0.98 1.29 50 1.40 1.56 859 ICW1620SPOS 16 20 19 50 1.06 1.34 50 1.45 1.67 997 ICW1624SPOS 16 24 19 50 1.12 1.42 50 1.53 1.86 1140 ICW1636SPOS 16 36 19 50 1.37 1.69 60 1.82 2.64 1618 ICW1650SPOS 16 50 19 50 1.57 1.92 60 2.05 3.34 2166 Conductor Triads ICW164STOS 16 4 19 50 0.61 0.84 50 0.95 0.72 403 ICW168STOS 16 8 19 50 0.82 1.06 50 1.17 1.09 650 ICW1612STOS 16 12 19 50 0.98 1.24 50 1.35 1.45 853 ICW1616STOS 16 16 19 50 1.10 1.37 50 1.48 1.74 1079 ICW1624STOS 16 24 19 50 1.33 1.64 60 1.78 2.52 1515 ICW1636STOS 16 36 19 50 1.58 1.96 60 2.09 3.48 2184 Dimensions and weights are nominal; subject to industry tolerances. Cross-sectional area for cable tray fill is in accordance with NEC® Section 392.22.

888.326.5174 • summit.com/marine 45 Impervious Continuously Welded

Impervious Continuously Welded (ICW) Armored Power and Control Cable, 600 Volts Application: For use in harsh environments where maximum Specifications: UL listed Type CWCMC. IEEE 45/IEEE 1580 conductor protection is required. Prevents entrance of water, (46 CFR Part 111.60-23) Marine Shipboard Cable. UL-1581 gas and corrosive elements into electrical core. Used for power, (70,000 BTU/hr) Flame Test. ICEA 70,000 BTU/hr and 210,000 control and lighting circuits in commercial and industrial BTU/hr Flame Tests. IEEE 383 (70,000 BTU/hr) Flame Test. environments. Approved for wet or dry locations at 90°C. For CSA-C22.2 No. 0.3, -40°C Cold Impact Test. ASTM B-3, B-8, use indoors or outdoors, aerially, in conduits, ducts, cable trays B-496. or direct burial in circuits not exceeding 600 volts. UL approved Construction: Soft bare annealed copper conductors, Class for use at 90°C for continuous operation, 130°C for emergency B stranding. Aluminum armor. XLP and Type XHHW-2 overload conditions, and 250°C for short circuit conditions. insulation. Flame retardant and sunlight resistant PVC jacket. May be used in Class I Division 2 Hazardous Locations.

Size Insulation Jacket Ground Wire Armor Nominal Weight Summit # of # of (AWG/ Thickness Thickness Diameter O.D. (lbs./ Number Conductors Strands # of Size kcmil) (mils) (mils) (in.) (in.) 1000 ft.) Conductors (AWG) ICW143 14 3 7 30 50 3 18 0.440 0.550 165 ICW144 14 4 7 30 50 2 16 0.480 0.590 195 ICW145 14 5 7 30 50 1 14 0.580 0.680 233 ICW147 14 7 7 30 50 1 14 0.620 0.720 272 ICW149 14 9 7 30 50 1 14 0.700 0.800 331 ICW1412 14 12 7 30 50 1 14 0.780 0.880 395 ICW1419 14 19 7 30 50 1 14 0.920 1.020 551 ICW1437 14 37 7 30 50 1 14 1.190 1.300 934 ICW123 12 3 7 30 50 3 16 0.480 0.590 223 ICW124 12 4 7 30 50 3 16 0.540 0.650 252 ICW125 12 5 7 30 50 1 12 0.620 0.720 294 ICW127 12 7 7 30 50 1 12 0.700 0.800 357 ICW129 12 9 7 30 50 1 12 0.840 0.940 448 ICW1212 12 12 7 30 50 1 12 0.880 0.980 528 ICW1219 12 19 7 30 50 1 12 1.070 1.170 755 ICW1237 12 37 7 30 50 1 12 1.330 1.430 1293 ICW103 10 3 7 30 50 3 14 0.580 0.690 290 ICW104 10 4 7 30 50 3 14 0.620 0.730 335 ICW109 10 9 7 30 50 1 10 0.920 1.020 482 ICW83 8 3 7 45 50 3 14 0.700 0.810 385 ICW84 8 4 7 45 50 2 12 0.780 0.890 480 ICW63 6 3 7 45 50 3 12 0.780 0.890 550 ICW64 6 4 7 45 50 2 10 0.880 0.990 660 ICW43 4 3 7 45 50 3 12 0.920 1.030 720 ICW44 4 4 7 45 50 2 10 1.070 1.180 915 ICW23 2 3 7 45 50 3 10 1.130 1.240 1035 ICW24 2 4 7 45 50 2 8 1.190 1.300 1436 ICW1/03 1/0 3 19 55 50 3 10 1.330 1.440 1500 ICW1/04 1/0 4 19 55 50 1 6 1.460 1.570 1955 ICW2/03 2/0 3 19 55 50 3 10 1.460 1.570 1860 ICW2/04 2/0 4 19 55 60 1 6 1.640 1.770 2410 ICW3/04 3/0 4 19 55 60 1 4 1.710 1.840 2970 ICW3/03 3/0 3 19 55 60 3 8 1.560 1.690 2310 ICW4/03 4/0 3 19 55 60 3 8 1.710 1.840 2790 ICW4/04 4/0 4 19 55 60 1 4 1.870 2.000 3560 ICW2503 250 3 37 65 60 3 8 1.870 2.000 3245 ICW2504 250 4 37 65 60 1 4 2.120 2.250 4170 ICW3503 350 3 37 65 60 3 7 2.120 2.250 4340 ICW3504 350 4 37 65 75 1 3 2.350 2.510 5670 ICW5003 500 3 37 65 75 3 6 2.410 2.570 6020 ICW5004 500 4 37 65 75 1 2 2.710 2.870 7780 ICW7503 750 3 61 80 85 3 5 3.030 3.210 8860

46 888.326.5174 • summit.com/marine Impervious Continuously Welded

Impervious Continuously Welded (ICW) Armored Power Cable, Unshielded, 2.4kV Application: For use in primary power and distribution circuits Specifications: IEEE 383 (70,000 BTU/hr) Flame Test. ICEA up to 2.4kV when installed in open air, conduit, duct, cable tray S-96-659/NEMA WC71. ASTM B-3, B-8, B-496. when CT rated, or direct buried in earth. For use in wet or dry Construction: Soft bare annealed copper conductors, Class B locations at 105°C. For commercial and industrial applications. stranding. Aluminum armor. EPR insulation, 133% insulation Approved for use at 105°C for continuous operation, 140°C level. Flame retardant and sunlight resistant PVC jacket. for emergency overload conditions, and 250°C for short circuit conditions.

Copper Size Insulation Jacket Insulation Weight # of # of Ground O.D. Summit Number (AWG/ Thickness Thickness Diameter (lbs./ Conductors Strands Wire Size (in.) kcmil) (mils) (mils) (in.) 1000 ft.) (AWG) ICW632KVEPRPVC 6 3 7 90 80 0.45 6 1.16 795 ICW432KVEPRPVC 4 3 7 90 80 0.50 6 1.26 1010 ICW232KVEPRPVC 2 3 7 90 80 0.56 6 1.39 1305 ICW132KVEPRPVC 1 3 19 90 80 0.60 4 1.48 1600 ICW1/032KVEPRPVC 1/0 3 19 90 80 0.64 4 1.56 1890 ICW2/032KVEPRPVC 2/0 3 19 90 80 0.68 4 1.66 2150 ICW3/032KVEPRPVC 3/0 3 19 90 110 0.73 3 1.83 2650 ICW4/032KVEPRPVC 4/0 3 19 90 110 0.79 3 1.95 3220 ICW25032KVEPRPVC 250 3 19 90 110 0.84 3 2.07 3830 ICW35032KVEPRPVC 350 3 37 90 110 0.95 2 2.30 4965 ICW50032KVEPRPVC 500 3 37 90 110 1.08 1 2.58 6610 ICW75032KVEPRPVC 750 3 61 90 140 1.27 1 3.05 9490

Mobile Apps for the Electrician Useful applications that you can use on the jobsite. Developed by Summit for the busy electrician. New apps are added frequently.

Learn more at summit.com/mobile

888.326.5174 • summit.com/marine 47 Impervious Continuously Welded

Impervious Continuously Welded (ICW) Armored Power Cable, Unshielded, 5kV 133% / 8kV 100% Insulation Level, Shielded Applications: Variable frequency drives or for use as feeders shield (ESS): Extruded thermoset semi-conductor stress and branch circuits in industrial power distribution systems control layer over the conductor per ICEA S-93-639 and UL per NEC Articles 328 and 330. For use in Class I, II and III, 1072. 115 mils ethylene propylene rubber (EPR) insulation Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous per ICEA S-93-639 and UL 1072. Extruded insulation shield locations per NEC Articles 501, 502, 503 and 505. May be (EIS) is a thermoset, semi-conducting polymeric layer, free installed on metal racks, troughs, in raceways, in cable trays stripping from the insulation per ICEA S-93-639 and UL 1072. or secured to supports spaced not more than six feet apart. Shield is 5 mil annealed bare copper tape with 25% overlap. Phase identification is color-coded polymeric identification Specifications: Design adherence: ICEA S-93-639/WC-74, tape laid under the shield — black, red and blue. Grounding 5-46 kV shielded power cable. AEIC CS8 specification for conductors are three split Class B stranded bare annealed shielded power cable. 5-46 kV UL 1072 medium-voltage copper, sized in accordance with UL 1072 and NEC Article 250. power cables. UL 1569 metal clad cables. UL 2225 cables and Insulated and grounding conductors are cabled together with cable fittings for use in hazardous locations. UL 1309 marine non‑hygroscopic fillers when required. Binder tape is applied shipboard cable. CSA C68.3. Flame Tests: ICEA T-29-520 over the cabled core. Armor is impervious, continuously welded (210,000 BTU/hr). IEEE 383 (70,000 BTU/hr). CSA FT4, and corrugated aluminum alloy per UL 1072 and UL 1569. IEEE 1202 (70,000 BTU/hr). UL 1072 IEC 60332-3. Category Armor conductivity meets the grounding requirements of A Compliances: UL Type MV-105, UL File #E90501. UL NEC Article 250. The jacket is flame-retardant, moisture- and Type MC-HL, SUN RES, CTUSE, DIR BUR, -40°C, FT4, UL sunlight-resistant PVC. Low temperature performance meets File #E90496 UL Listed Marine Shipboard, UL File #E85994. ASTM D746 brittleness temperature at or below -40°C. American Bureau of Shipping (ABS). Listed for CWCMC. Construction: Bare annealed copper conductors per ASTM B3. Compact stranding per ASTM B496 extruded strand

Size Insulation Jacket Bare Armor Weight # of # of O.D. Summit Number (AWG/ Thickness Thickness Ground Diameter (lbs/ Conductors Strands (in.) kcmil) (mils) (mils) (AWG) (in.) 1000 ft.)

ICW635KVEPRPVC 6 3 7 115 50 3 1.37 1.48 1,121 ICW435KVEPRPVC 4 3 7 115 60 3 1.51 1.65 1,418 ICW235KVEPRPVC 2 3 7 115 60 3 1.64 1.78 1,731 ICW135KVEPRPVC 1 3 19 115 60 3 1.69 1.82 1,978 ICW1/035KVEPRPVC 1/0 3 19 115 60 3 1.78 1.91 2,259 ICW2/035KVEPRPVC 2/0 3 19 115 60 3 1.92 2.05 2,626 ICW4/035KVEPRPVC 4/0 3 19 115 60 3 2.15 2.28 3,650 ICW25035KVEPRPVC 250 3 19 115 60 3 2.23 2.36 4,060 ICW35035KVEPRPVC 350 3 37 115 75 3 2.45 2.61 5,045 ICW50035KVEPRPVC 500 3 37 115 75 3 2.75 2.92 7,137

Impervious Continuously Welded (ICW) Armored Power Cable, Shielded, 15kV Application: For use in harsh environments where maximum Flame Tests. UL listed, NEC Type MV-105 and Type MC, conductor protection is required. Used for primary power and UL1072. Single conductors are qualified per AEIC CS8. feeder circuits in commercial and industrial power distribution CSA-C22.2 No. 0.3, -40°C Cold Impact Test. UL listed Type systems. Approved for use in wet or dry locations at 105°C. For CWCMC. IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine use indoors or outdoors, aerially, in conduits, ducts, cable trays or Shipboard Cable. ASTM B-8, B-496. direct burial in circuits not exceeding 15,000 volts. UL approved Construction: Soft bare annealed copper conductors, Class B for use at 105°C for continuous operation, 140°C for emergency stranding. Semi-conducting conductor shield. EPR insulation overload conditions, and 250°C for short circuit conditions. May with semi-conducting insulation shield. Uncoated 5 mil copper be used in Class I Division I Hazardous Locations. tape shield. Aluminum armor. Flame retardant, sunlight Specifications: ICEA 70,000 BTU/hr and 210,000 BTU/hr resistant PVC jacket.

Copper Size Insulation Jacket Armor Weight # of # of Ground O.D. Summit Number (AWG/ Thickness Thickness Diameter (lbs./ Conductors Strands Wire Size (in.) kcmil) (mils) (mils) (in.) 1000 ft.) (AWG) ICW2315KVSEPRPVC 2 3 7 220 75 6 2.35 2.50 2790 ICW1315KVSEPRPVC 1 3 19 220 75 4 2.35 2.50 3180 ICW2315KVSEPRPVC 1/0 3 19 220 75 4 2.47 2.62 3425 ICW2315KVSEPRPVC 2/0 3 19 220 75 4 2.55 2.70 3850 ICW2315KVSEPRPVC 3/0 3 19 220 75 3 2.81 2.96 4950 ICW2315KVSEPRPVC 250 3 19 220 75 3 3.03 3.18 5700 ICW2315KVSEPRPVC 350 3 37 220 75 2 3.22 3.40 7030 ICW2315KVSEPRPVC 500 3 37 220 85 1 3.41 3.59 8690

48 888.326.5174 • summit.com/marine Connectors and Terminals

Type YA-L One Hole HYLUG™, Description: Standard barrel lugs for copper cable 600 volts more information. Inspection hole ensures proper insertion of to 35 kV. Copper compression terminals for regular-duty cable. Tin-plated. Marked with die index and color code. UL applications. 45° and 90° are available. Contact Summit for Listed 90°C

Stud Conductor SIze Tongue Figure Dimensions (In.) Summit Hole Navy Width Number Size 2 (In.) AWG/kcmil mm * (In.) (B) (T) (L) B BUYA8CLBOX 37/24 8 Weld 8 AWG 6 Sol. † 10 23 8 - 10 0.41 0.44 0.08 1.16 T BUYA8CL1BOX 37/24 8 Weld 8 AWG 6 Sol. † 10 23 1/4 0.44 0.44 0.08 1.26 BUYA6CLBOX 6 AWG — — 1/4 0.45 0.54 0.08 1.18 L BUYA5CLBOX 5 AWG — 30 1/4 0.44 0.81 0.07 1.65 BUYA4CLBOX 4 AWG — 40 1/4 0.50 0.81 0.09 1.74 B BUYA4CL6BOX 4 AWG — 40 1/2 0.71 0.81 0.06 2.20 BUYA3CL 3 Str./2 Sol. 25 50 5/16 0.55 0.88 0.09 1.88

T BUYA2CLBOX 2 AWG 35 60 5/16 0.61 0.88 0.11 1.93 45° BUYA2CL6BOX 2 AWG 35 60 1/2 0.73 0.88 0.09 2.32 L BUYA1CLBOX 1 AWG 50 75 5/16 0.68 0.88 0.01 1.94 BUYA1CL6BOX 1 AWG 50 75 1/2 0.73 0.88 0.09 2.37 BUYA25L6BOX 1/0 AWG — 100 1/2 0.75 0.88 0.12 2.34 B BUYA26LBOX 2/0 AWG 70 125 3/8 0.83 0.94 0.12 2.19 90° BUYA26L6BOX 2/0 AWG 70 125 1/2 0.83 0.94 0.12 2.44 T BUYA27LBOX 3/0 AWG — 150 1/2 0.91 1.00 0.13 2.54 BUYA28LBOX 4/0 AWG — 200 1/2 1.02 0.88 0.14 2.46 L BUYA29LBOX 250 kcmil — 250 1/2 1.11 1.06 0.14 2.67 BUYA30L 300 kcmil 150 300 1/2 1.20 1.03 0.16 2.69 BUYA31L 350 kcmil 185 350 1/2 1.29 1.06 0.18 2.75 BUYA32L 400 kcmil — 400 5/8 1.38 1.19 0.19 3.18 BUYA34L 500 kcmil 240 — 5/8 1.55 1.27 0.20 3.37 BUYA36L 600 kcmil 300 — 5/8 1.74 1.38 0.27 3.72 BUYA38L 700 kcmil — — 5/8 1.84 1.45 0.27 3.66 BUYA39L 750 kcmil — — 5/8 1.91 1.42 0.27 3.67 BUYA40L 800 kcmil 400 — 5/8 1.98 1.42 0.30 3.81 BUYA44L 1000 kcmil 500 — 5/8 2.19 1.65 0.33 4.04

* The mm2 conductor sizes listed are the recommendations for Class 2 conductor. † The mm2 conductor size listed is for both Class 2 and Class 5 conductor. For applications greater than 2000 volts, consult cable manufacturer for voltage stress relief instructions. Note: All dimensions shown are for reference only.

Aluminum Cord Grips Niedax-Kleinhuis IPON Cord Connectors Tuff Seal™ RSR Series Aluminum Cord Grips are UL Listed and CSA Certified for use in both NPT, PG and Metric Sizes indoor and outdoor applications to prevent cable Material: pullout, control arc of bend, and to provide a Halogen free polyamide, silicone free, tight seal against environmental elements such as neoprene sealing grommet dirt, moisture and coolants. Temperature Range: Encompasses conduit sizes from 1/2" to 3" with Permanent -30°C to 100°C (Short term 150°C) fittings offered in machined aluminum, nickel- Protection Class: plated aluminum, steel, stainless steel, nylon and IP68, 5 bar / comparable to NEMA 6P Valox®. Other features include: Flame Resistance: UL 94 V0, incandescent wire test 850°C to • Designed with a combination tightening VDE Standard 0471/DIN IEC 695, Part 2-1 surface with hex area and knurled surface. • Available with or without wire mesh. Easy to Install • Optional embedded Viton® O-Ring ensures Insert your cord into the IPON, tighten the a watertight and corrosion-resistant seal. dome-nut and the cable is fixed, centered, • Available in NPT, Pg/ISO or metric threads. sealed and strain relieved. No disassembly required. Provides exceptional corrosion resistance and high wear resistance. Nickel-plated connectors Versatile also feature attractive finish similar to that of 7 NPT fittings (3/8"- 2") cover cable diameters polished stainless steel. Tuff Seal RSR Cord Grips from .157" - 1.7". TheIPON is available in protect cable from damage and pullout and are NPT, Pg & Metric thread types. (Cable ranges used in conduit hubs or knockouts at the point from .177" up to 1.732"). Contact Summit for a where the electrical cable is to be terminated. complete list of offerings.

888.326.5174 • summit.com/marine 49 Tools/Accessories Cutting Pliers

High Leverage, 8-Inch Diagonal Cutting Pliers, Angled Head

Custom US-made tool steel. Induction hardened cutting knives available for some styles. State-of-the-art, dual-material handles, for long life. Hot-riveted joint ensures smooth action and no which provide a better grip without sacrificing tool strength or handle wobble. Short jaws and beveled cutting edges permit durability. Angled head design for easy work in confined spaces. close cutting of wire. 2000 Series pliers available. Cuts ACSR, High-leverage design. Rivet is closer to the cutting edge for 36% screws, nails, and most hardened wire. Plastic-dipped handles greater cutting power than other plier designs. for comfort and ease of identification. Journeyman™ pliers

Summit Cutting Handle Handle Jaw Jaw Jaw Overall Weight Number Knives Color Finish Length Thickness Width Length (lbs.) KLD2488 Standard Red Plastic Dipped 13/16" 7/16" 1-3/16" 8-1/16" .60 KLJ2488 Standard Red/Black Journeyman 13/16" 7/16" 1-3/16" 8-1/8" .61 KLD200048 Standard Royal Blue Plastic Dipped 13/16" 7/16" 1-3/16" 8-1/16" .60 KLJ200048 Standard Light-Blue/Black Journeyman 13/16" 7/16" 1-3/16" 8-1/8" .67

High Leverage, Heavy Duty, Side Cutting Pliers, 2000 Series®

Custom, US-made tool steel. Hot-riveted joint ensures smooth styles. State-of-the-art, dual-material handles, which provide action and no handle wobble. Induction hardened cutting a better grip without sacrificing tool strength or durability. knives for long life. Unique handle tempering helps absorb Cuts ACSR, screws, nails and most hardened wire. High- the “snap” when cutting wire. 2000 Series pliers available. Cuts leverage design. Rivet is closer to the cutting edge for 46% ACSR, screws, nails and most hardened wire. “Handform” greater cutting and gripping power than other plier designs. handles for full gripping and cutting power. Precision-hardened Streamlined design with sure-gripping, cross-hatched knurled plier head for on-the-job toughness. Sure-gripping cross- jaws. 2000 Series - Heavy-duty cutting knives. Cuts ACSR, hatched knurled jaws. Plastic-dipped handles for comfort and screws, nails and most hardened wire. Features combination ease of identification. Journeyman™ pliers available for some polished and black-oxide finish.

Summit Handle Handle Jaw Jaw Jaw Overall Weight Size Number Color Finish Length Thickness Width Length (lbs.) KLD20007 7-inch Royal Blue Plastic Dipped 1-9/32" 1/2" 1-1/32" 7-7/8" 0.66 KL20008 8-inch Royal Blue Plastic Dipped 1-7/16" 5/8" 1-7/64" 8-11/16" 0.85 KL20009NE 9-inch Royal Blue Plastic Dipped 1-19/32" 5/8" 1-1/4" 9-3/8" 1.09

9 Inch, High Leverage, Heavy Duty Side Cutting Pliers

Custom, US-made tool steel. Hot-riveted joint ensures smooth ease of identification. Journeyman™ pliers available for some action and no handle wobble. Induction hardened cutting styles. State-of-the-art, dual-material handles, which provide knives for long life. Unique handle tempering helps absorb a better grip without sacrificing tool strength or durability. the “snap” when cutting wire. 2000 Series pliers available. Cuts Cuts ACSR, screws, nails and most hardened wire. High- ACSR, screws, nails and most hardened wire. “Handform” leverage design. Rivet is closer to the cutting edge for 46% handles for full gripping and cutting power. Precision-hardened greater cutting and gripping power than other plier designs. plier head for on-the-job toughness. Sure-gripping, cross- Streamlined design with sure-gripping, cross-hatched knurled hatched knurled jaws. Plastic-dipped handles for comfort and jaws. Features combination polished and black-oxide finish.

Summit Handle Handle Jaw Jaw Jaw Nose Overall Weight Number Color Finish Length Thickness Width Type Length (lbs.) Heavy-Duty KLHD20009NE Light Red Oversized 1-19/32" 5/8" 1-1/4" New England 9-1/2" 1.15 Plastic Dipped KLD2139 Dark Blue Plastic Dipped 1-19/32" 5/8" 1-1/4" Square 9-3/8" 1.07

WireMan™ Side Cutting Pliers Summit Description Number Professional quality tools for maximum life and performance ID304419 7” Smart Grip Side Cutting Premium quality tool steel provides excellent durability ID305419 7” Side Cutting Precision mated blades for easy cutting Smart-Grip™ ID304420 8” Smart Grip Side Cutting textured santoprene™ handles provide a sure grip ID305420 8” Side Cutting and are resistant to perspiration, water, oil ID354012 9-1/4” Smart Grip Side Cutting and chemicals Smart Grip™ Handle ends are color coded and have ID355012 9-1/4” Side Cutting FastFinder™ letter icons for quick ID304430 9-1/4” Smart Grip Side Cutting w/ Crimp identification Lifetime guarantee ID305430 9-1/4” Side Cutting with Crimp

50 888.326.5174 • summit.com/marine Tools/Accessories Cable Cutters

Ratcheting Cable Cutters Standard Cable Cutters Cleanly cuts copper up to 400 MCM, as well Lightweight, yet efficient shear-type cable as aluminum and multi-conductor cables up cutters. Replaceable hook-jaw blades grab and to 600 MCM. Unique ratchet action holds hold cable while shear-cutting action makes cable tight and allows rapid, straight cuts with clean cuts. Exceptionally strong fiberglass minimum effort. Hold-open spring speeds handles with heavy vinyl grips for comfort and cutting action. Quick-release lever opens blade at slip resistance. Heavy-duty pins in head serve anytime during operation. Large, finger-formed as blade-stops. Jaws are forged tool steel with handles have limit guards and plastic covering black-oxide finish for long life. Beveled tips for comfort. Compact, lightweight tool can be assure positive mating, and hinge on a rugged locked in closed position for pouch carrying. Not bolt with a pin-set nut to maintain proper designed for cutting steel or ACSR. blade tension. Makes a clean, even cut for ease in fitting lugs and terminals. Not designed for Summit Handle Maximum Cable Overall Weight cutting steel or ACSR. Number Color Cutting Capacity Length (lbs.) 400 copper, KL63060 Red 600 aluminum and 10" 1.7 Summit MCM Cable Cutting Soft Cable Weight Length multi-conductor Number Capacity (kcmil) Cutting Capacity (lbs.) 500 Copper, KL63041 25-1/2" 1-3/8" 5.25 750 Aluminum Ratcheting Cable Cutters 1000 Copper, KL63045 32" 1-3/4" 8.00 1200 Aluminum High leverage ratchet mechanism for single- handed cutting of copper and aluminum cables, leaving no burrs or sharp edges. Patented two-step ratchet mechanism requires fewer strokes per cut. Journeyman™ Quick release opens blades easily in every cutting position. High Leverage Cable Cutters Precision ratcheting mechanism holds cable tight and allows rapid, straight cuts with minimum effort. Hardened steel cutting Cuts up to 4/0 aluminum AWG (no ACSR), blades for lasting strength and sharpness. Plastic covered handles 2/0 AWG soft copper and 100-pair 24 with hand guards for comfort and firm grip. Locking lever keeps AWG communications cable. handles closed for easy transport, to fit in tool box or bag. Cuts High leverage for greater copper and aluminum up to 1000 MCM; frequent use of 750 MCM. cutting power. Precision, one- Communications Summit Cutting Handle Overall Weight hand shearing Cable Cutting Number Capacity Color Length (lbs.) action. Capacity Copper and Summit Handle Handle Overall Weight Aluminum, KL63750 2-1/16" Red 12-1/8" 1.76 Number Color Finish Length (lbs.) 1000 MCM KLJ63050 Red/Black Journeyman 9-9/16" 0.98 maximum.

Ratcheting Cable Cutters Compact Ratcheting Cable Cutters Hardened steel blades ensure consistent cuts Compact 12" design allows for one-handed use and long-term durability. Rounded blade of the ratcheting cutter mechanism, so other design minimizes cable distortion during hand can position cable to ensure proper cut. cutting. Quick release mechanism simplifies Holds cable tight and allows rapid, straight cuts blade back-out. Locking mechanism keeps with minimum effort. Quick-release lever opens handles closed for easy storage. Molded-in blade at anytime during operation. Compact, foot provides stability and leverage when lightweight tool can be locked in closed position making multiple cuts. for easy transportation in bucket, bag or pouch.

Summit Handle Summit Maximum Cutting Capacity Number Capacity Number Color 750 kcmil Hard 1000 MCM Aluminum, 600 MCM Copper, ID35053 Drawn Copper KL63601 Red and Aluminum 2 -1/16" Diameter Communication Cable

Performance WireMan™ Cable Cutters Ratchet Cable Cutters Professional quality tool for maximum life and performance. Simple, one-hand operation. Two-speed Premium quality steel provides excellent durability Precision ratchet mechanism adjusts for light/heavy mated blades for easy cutting. Smart-Grip™ textured cutting. Well-suited for tight work spaces. Santoprene™ handles provide a sure grip and are resistant to Specially designed blade improves cutting capacity. perspiration, water, oil, and chemicals.

Summit Maximum Overall Jaw Weight Summit Maximum Overall Number Capacity Length Opening (lbs.) Number Capacity Length 600 kcmil Copper, ID355052 2/0 Copper and Aluminum 9-1/2" GR45206 10" 1-7/16" 1.5 500 kcmil Aluminum

888.326.5174 • summit.com/marine 51 Tools/Accessories Cable Cutters

Long Arm Cable Cutters Burndy Patriot® • High strength forged blades for durability. Hydraulic Self-Contained • Precision-ground jaws make clean Cable Cutter cuts with minimal cable distortion • For copper and aluminum only. The BURNDY® 18V battery-powered • Replaceable blades. cutting tool is compact, fast, easy to use and incorporates the latest in battery tool technology. The ergonomic design allows one-hand operation so that the other is free to manipulate the conductor in the proper cutting position. • Specialized latch style cutting head that allows interference-free closure for mid-span cuts. • Cutter head rotates 180° to get into tight areas easier. • Cuts up to 2.45" diameter copper and aluminum cable. • Operates on industry standard 18V Ni/MH batteries that eliminate

Summit Arm Cutting Capacity voltage depression or “memory” issues. Number Length (kcmil) • Equipped with a high-impact formed carrying case to hold the tool, ID35031 14" 250 a tool retention lanyard, a battery charger and two batteries. BUPATCUT245CUAL18V ID35032 22" 500 • Provided with a 5-year manufacturer’s limited warranty (excluding blades), and 1-year on batteries and charger. ID35033 32" 1000 Cable Cutter for 2/0 and Smaller Cable Battery Powered Cable Cutter • Drop-forged high carbon steel construction. Powered with a state of the art 18V lithium ion (Li-ion) battery. Provides • Precision ground, hardened cutting edges 70% more cycles per charge and faster cycle times. LED light provides the provide accurate cuts without cable distortion. operator with the battery charge and tool maintenance status. Small size • Designed for maximum leverage. makes the ES32L an excellent tool for use inside panel boxes. • Vinyl coated, comfort-grip handles. • Manufacturer lifetime guarantee. • In-line tool style is lightweight and very easy to control. • One trigger controls all tool functions. • Cutting head rotates 350°. • Tools automatically retract when the cutting cycle is complete. • Overmolded, tacky grip areas make gripping the tool easier and more comfortable. ID35052 • LED work light illuminates dark work areas. • Greenlee battery-powered crimping tools now use bio-degradable oil. • Smart chargers control the charging current, charging voltage and battery temperature to maximize battery life. • Available with 120V, 12V or 230V battery charger or with 120V or 230V corded adapter in place of batteries and charger. Hydraulic Cable Cutter Thehydraulic cutter cuts in 7 seconds. Jaws GRES32L11 slide open quickly to save time between cuts. 11-ton (97 kN) ram powers cutting jaws. Jaws

are specially hardened and precision-ground ® to hold sharpness. Lightweight and easy to use. Gator Plus Battery Powered Cable Cutter • Ram automatically retracts after the cut is complete. No need to push a retract lever. Automatically ready to perform the next cut. • Two-speed pump advances the ram quickly to start the cut. • Cutting blades are specially hardened and precision ground GR750 to hold their sharpness. • Lightweight and easy to use. • Cutting head rotates 360° for making cuts in tight locations, and flips open to make mid-span cuts easy. • Includes one-hour battery charger, carrying case and two batteries. • Choice of a 120-volt, 230-volt or 12-volt battery charger.

Summit Cutting Overall Weight Battery Number Capacity Length (lbs.)

2" Copper and GRESG50L11 12V 15-3/4" 10 Aluminum Cable

52 888.326.5174 • summit.com/marine Tools/Accessories Crimping and Stripping Tools

Wire Stripper/Cutter, Dieless Hand Operated Solid and Stranded Wire Hydraulic Crimping Tool Precision shear-type blades for clean cuts on solid • Pressure system automatically changes and stranded copper wire. Easy-to-read markings crimping force for each connector and size. on both sides. Curved handles help reach into • Seven indent profiles. confined areas. Wire looping and bending holes. • Automatic two-speed pump. Coil spring provides fast, self-opening action. • 15 ton maximum crimping force. Precision-ground stripping holes. Strong- • Head rotates 180°. gripping, serrated nose for easy bending, shaping, • Hinged head. and pulling of wire. Screw-shearing holes. Handy • Wire range 1000 kcmil AL/CU - #4 CU. closure lock for convenient storage. Double- • Durable steel carrying case. dipped comfort grips.

ILIDT12N Summit Handle Overall Screw Weight Strips and Cuts Number Color Length Shearing (lbs.) Journeyman™ 20 - 30 AWG Solid Blue and 6-32, KL11057 7-1/8" and 22 - 32 AWG 0.32 Crimping/Cutting Tool, Red 8-32 Stranded Non-Insulated/Insulated Connectors Dual NM Cable Strippers/Cutters Designed to crimp insulated and non-insulated 10 to 22 AWG solderless terminals and connectors. 10/2 and 12/2 stripping slots quickly remove Tapered nose design for working in confined outer jacket of Type NM-B non-metallic-sheathed spaces. Contoured thumb area for additional cable. Stripping holes easily remove insulation comfort and positive feel. Specially hardened on 10 and 12 AWG lead wire. Precision staggered cutter. Hot-riveted joint ensures smooth action and no handle wobble. blades for square, clean cuts on solid copper wire. Narrow nose fits into tight places. Precision,

Summit Weight shear-type blades for square, clean cuts on solid Handle Color Handle Finish Overall Length Number (lbs.) copper wire. Curved handles help reach into KLJ1005 Red/Black Journeyman 9-3/4" 0.84 confined areas. Strong-gripping, serrated nose for easy bending, shaping and pulling of wire. Wire looping, bending, and screw-shearing holes. Coil spring provides fast, self-opening action. Handy Large Crimp Tool, closure lock for convenient storage. Double- Compound Action dipped comfort grips. • Crimps 6 - 4/0 AWG Summit Handle Overall Screw Weight Number Color Length Shearing (lbs) lugs and terminals. • All-in-one, integral crimp nest; KLK1210 Yellow/Orange 7-4/5" 6-32 and 8-32 .43 no removable parts or rotating dies. • High-leverage handles and compound-action mechanism Romex® Cable T®-Stripper for superior mechanical advantage. Easy, one-step stripping of outer jacket of NM • Ultra-comfortable hand grips for easy use. cable - no slitting required. Versatility to strip, • Adjustment screw allows user to cut and loop conductor wires with precision and control crimp depth. ease. Stripping holes for 12 or 14 AWG solid wire. Locking pawl for safe storage. Summit Handle Weight Crimps Overall Length Number Color (lbs.) Summit 6-4/0 AWG Description Number KL2006 lugs, Black 19-1/2" 3.8 terminals ID45248 14/2 NM Cable T®-Stripper ID45249 12/2 NM Cable T®-Stripper ID45621 Reflex™ Super 12/2 & 14/2 NM Cable ®T -Stripper

WireMan™ Multi-Crimp Tool Multi-Purpose Professional quality tools for maximum life and 6-in-1 Tool performance. Premium quality tool steel provides excellent durability. Precision-mated blades for • Cleanly shears bolts. • Easily cuts and strips wire. easy cutting Smart-Grip™ textured Santoprene™ • Measures stud sizes. handles provide a sure grip and are resistant to • Gauges wire sizes. perspiration, water, oil, and chemicals. Smart- • Crimps insulated terminals. Grip™ Handle ends are color-coded and have • Plastic-covered cushioned handles for comfort. FastFinder™ letters icons for quick identification. Summit Handle Overall Bolt Size Weight(lbs) Summit Number Color Length Description Number 4-40, 6-32, ID355431 9-3/4" WireMan™ Multi-Crimp Tool - Bare Terminals KL1000 8-32, 10-24, Red 7-3/4" 0.44 10-32 ID305429 9-3/4" WireMan™ Multi-Crimp Tool

888.326.5174 • summit.com/marine 53 Reference Low Smoke Zero Halogen Selection Guide

Product Code Specifications M2X M2XH M2XCH FM2XAH FM2XAAH Cable Specs Fire Specs Halogen Free • • • • • Low Smoke Density • • • • • Flame Retardant • • • • • Fire Resistant Physical Specs Oil Resistant (Temporary Contact) • • • • • Rated Voltage 600v/1kV 600v/1kV 600v/1kV 60/250v 60/250v Test Voltage 3.5kV 3.5kV 3.5kV 1.5kV 1.5kV Working Temperature °C -40/90 -40/90 -40/90 -40/90 -40/90 Bending Radius (x cable outer diameter by fixed installation) 4 6 8 8 10 Standard Production Scale Min. - Max. Number of Cores (p:pairs) 1 1-60 1-60 1p-37p 1p-24p Cross Section(s) (mm2) 0.5-300 1-630 1-630 0.5-0.75 0.5-1.5 Cable Construction Conductor IEC 60228, Copper Wire Class Standard (Optional) 5-(2) 2-(5) 2-(5) 2-(5) 2-(5) Core Insulation2 Mica Tape XLPE • • • • XLPO • HEPR PUR PVC PVC + Polyamide Pairs and Individual Screen Separating Foil Over Pairs • Individual Screen Material3 Al+d Separating Foil Over Individual Screen Bedding PVC Comp Inner Sheath Flame Retardant Compound Halogen Free Compound ◊ ◊ Rubber Compound PVC Overall Screen Separating Foil Under Screen ◊ • • Shield/Screen Material3 CWB Al+d Al+d Separating Foil Under Sheath ◊ • • Outer Sheath4 PVC (ST2) SHF1 (Black or Gray) • • • • SHF1 (Green) Chloroprene Flame Retardant PVC PUR

● - Standard use ◊ - Usage depends on cross section or other features

1 - Production Scale: 2 - Core Insulation: 3 - Shield/Screen Material: 4 - Outer Sheath: Indicates the standard production HEPR: High-grade Ethylene Propylene CWB: Electrolytic plain copper wire PVC (ST2): Flame retardant, oil range of “core numbers” and “cross Rubber braided screen resistant PVC- based compound sections” for that cable type. Please XLPO: Cross Linked Polyolefin CT: Electrolytic plain copper tape SHF1: (HM4-SHF1) HD 604. Halogen keep in mind that not every core PVC + Polyamide: Double Insulation GSWB: Galvanized steel wire braided free, flame retardant, low smoke, number within mentioned range may by PVC screen thermoplastic polyolefin- based be available, and not all cross sections and Polyamide Al + d: Aluminum foil tape with tinned compound are available for every core number. XLPE: Cross Linked Polyethylene copper drain wire Chloroprene Based Material: Flame See related catalog page(s) for more Mica Tape: Copper wire(s) are wrapped WBT: Water blocking tape retardant and oil resistant information. by a mica tape under insulation to gain PUR: Polyurethane compound fire resistance

54 888.326.5174 • summit.com/marine Reference Low Smoke Zero Halogen Selection Guide

Product Code Specifications M2X M2XH M2XCH FM2XAH FM2XAAH Standards Construction DIN 89158 DIN 89159 DIN 89160 IEC 60502/1 IEC 60092/353 • • • IEC 60092/375 • • IEC 60092/376 • • Construction, Test and Material VG 88775/66 VG 88777/66 VG 88778/66 Tests and Materials IEC 60092/350 • • • • • IEC 60092/351-359 • • • • • EMC DIN EN 50147/1 Flame R. IEC 60332/1-3 Cat A • • • • • Fire Res. IEC 60331 (180min) Smoke Density IEC 60754/1-2, 61034/1-2 • • • • • DIN EN 50268/1-2 • • • • • Approval Certificates ABS (American Bureau of Shipping) • • • • • BV (Bureau Veritas) • • • DNV (Det Nordske Veritas) GL (Germanischer Lloyd) • • • LR (Lloyd’s Register) • • • • • Class NK (Nippon Kaiji Kyokai) • • • • • RINA (Registro Italiano Navale) • • RMRS (Russian Maritime Register of Shipping) Türk Loydu (Turkish Lloyd)

● - Standard use ◊ - Usage depends on cross section or other features

1 - Production Scale: 2 - Core Insulation: 3 - Shield/Screen Material: 4 - Outer Sheath: Indicates the standard production HEPR: High-grade Ethylene Propylene CWB: Electrolytic plain copper wire PVC (ST2): Flame retardant, oil range of “core numbers” and “cross Rubber braided screen resistant PVC- based compound sections” for that cable type. Please XLPO: Cross Linked Polyolefin CT: Electrolytic plain copper tape SHF1: (HM4-SHF1) HD 604. Halogen keep in mind that not every core PVC + Polyamide: Double Insulation GSWB: Galvanized steel wire braided free, flame retardant, low smoke, number within mentioned range may by PVC screen thermoplastic polyolefin- based be available, and not all cross sections and Polyamide Al + d: Aluminum foil tape with tinned compound are available for every core number. XLPE: Cross Linked Polyethylene copper drain wire Chloroprene Based Material: Flame See related catalog page(s) for more Mica Tape: Copper wire(s) are wrapped WBT: Water blocking tape retardant and oil resistant information. by a mica tape under insulation to gain PUR: Polyurethane compound fire resistance

888.326.5174 • summit.com/marine 55 Reference Low Smoke Zero Halogen Terminal Selection

Terminal Remke Burndy Thomas & Betts Panduit Cable Sizes Tubes Part # mm2 1 Hole 2 Hole 1 Hole 2 Hole 1 Hole 2 Hole Male CGB Grommet Std Barrel Std Barrel Std Barrel Std Barrel Std Barrel Long Barrel M2X Construction M2X1x25 1 x 25 M038 - 3/8" RSR-100 SRB-106 YA2CL YA2CL-2TC 54145-TB 54207 LCA2 LCD2 M2X1x35 1 x35 M038 - 3/8" RSR-100 SRB-107 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2X1x50 1x 50 M038 - 3/8" RSR-100 SRB-108 YA25L YA25L-2TC 54158 54209 LCA1/0 LCD1/0 M2X1x70 1x 70 M012- 1/2" RSR-100 SRB-110 YA27L YA27L-2TC 54165-TB 54211 LCA3/0 LCD3/0 M2X1x95 1 x 95 M012- 1/2" RSR-100 SRB-110 YA29L YA29-2LN 54113 54275 LCA250 LCD250 M2X1x120 1 x 120 M012- 1/2" RSR-200 SRB-211 YA30L YA30-2LN 54114 54280 LCA300 LCD300 M2XH Construction M2XH2x1.5 2 x 1.5 M038 - 3/8" RSR-100 SRB-106 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH2x2.5 2 x 2.5 M038 - 3/8" RSR-100 SRB-107 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH2x4 2 x 4 M038 - 3/8" RSR-100 SRB-107 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH2x6 2 x 6 M038 - 3/8" RSR-100 SRB-108 YA8CL YA8CL-2TC 54130 54204 LCA8 LCD8 M2XH3x1.5 3 x 1.5 M038 - 3/8" RSR-100 SRB-106 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH3x2.5 3 x 2.5 M038 - 3/8" RSR-100 SRB-107 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH3x4 3 x 4 M038 - 3/8" RSR-100 SRB-108 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH3x6 3 x 6 M038 - 3/8" RSR-100 SRB-108 YA8CL YA8CL-2TC 54131 54204 LCA8 LCD8 M2XH3x10 3 x 10 M012- 1/2" RSR-100 SRB-110 YA6CL YA6CL-2TC 54135 54205 LCA6 LCD6 M2XH3x16 3 x 16 M012- 1/2" RSR-200 SRB-211 YA4CL YA4CL-2TC 54139 54206 LCA4 LCD4 M2XH3x25 3 x 25 M100- 1" RSR-300 SRB-315 YA2CL YA2CL-2TC 54145-TB 54207 LCA2 LCD2 M2XH3x35 3 x 35 M100- 1" RSR-300 SRB-316 YA1CL YA1CL-2TC 54109 54208 LCA1 LCD1 M2XH3x50 3 x 50 M100- 1" RSR-400 SRB-520 YA25L YA25L-2TC 54158 54209 LCA1/0 LCD1/0 M2XH3x70 3 x 70 M114- 1-1/4" RSR-400 SRB-522 YA27L YA27L-2TC 54165-TB 54211 LCA3/0 LCD3/0 M2XH3x95 3 x 95 M112- 1-1/2" RSR-600 SRB-625 YA29L YA29-2LN 54113 54275 LCA250 LCD250 M2XH3x120 3 x 120 M200- 2" RSR-600 SRB-627 YA30L YA30-2LN 54114 54280 LCA300 LCD300 M2XH3x150 3 x 150 M200- 2" RSR-700 SRB-731 YA31L YA31-2LN 54115 54215 LCA350 LCD300 M2XH3x185 3 x 185 M200- 2" RSR-700 SRB-733 YA32L YA32-2LN 54118 54286 LCA400 LCD400 M2XH4x1.5 4 x 1.5 M038 - 3/8" RSR-100 SRB-107 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH4x2.5 4 x 2.5 M038 - 3/8" RSR-100 SRB-107 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH4x4 4 x 4 M038 - 3/8" RSR-100 SRB-108 YAV10 YAV10-2TC 54101 54201 LCA10 LCD10 M2XH4x6 4 x 6 M012- 1/2" RSR-100 SRB-109 YA8CL YA8CL-2TC 54131 54204 LCA8 LCD8 M2XH4x10 4 x 10 M012- 1/2" RSR-200 SRB-211 YA6CL YA6CL-2TC 54135 54205 LCA6 LCD6 M2XH4x16 4 x 16 M034- 3/4" RSR-200 SRB-212 YA4CL YA4CL-2TC 54139 54206 LCA4 LCD4 M2XH4x25 4 x 25 M100- 1" RSR-300 SRB-316 YA2CL YA2CL-2TC 54145-TB 54207 LCA2 LCD2 M2XH4x35 4 x 35 M114- 1-1/4" RSR-400 SRB-518 YA1CL YA1CL-2TC 54109 54208 LCA1 LCD1 M2XH4x50 4 x 50 M114- 1-1/4" RSR-400 SRB-522 YA25L YA25L-2TC 54158 54209 LCA1/0 LCD1/0 M2XH4x70 4 x 70 M112- 1-1/2" RSR-600 SRB-625 YA27L YA27L-2TC 54165-TB 54211 LCA3/0 LCD3/0 M2XH4x95 4 x 95 M200- 2" RSR-600 SRB-627 YA29L YA29-2LN 54113 54275 LCA250 LCD250 M2XH4x120 4 x 120 M200- 2" RSR-700 SRB-731 YA30L YA30-2LN 54114 54280 LCA300 LCD300 M2XH4x150 4 x 150 M200- 2" RSR-700 SRB-733 YA31L YA31-2LN 54115 54215 LCA350 LCD300 M2XH4x185 4x 185 M212- 2-1/2" RSR-700 SRB-737 YA32L YA32-2LN 54118 54286 LCA400 LCD400 M2XH7x1.5 7 x 1.5 M038 - 3/8" RSR-100 SRB-108 ------M2XH7x2.5 7 x 2.5 M012- 1/2" RSR-100 SRB-109 ------M2XH10x1.5 10 x 1.5 M012- 1/2" RSR-100 SRB-110 ------M2XH10x2.5 10 x 2.5 M012- 1/2" RSR-200 SRB-211 ------M2XH14x1.5 14 x 1.5 M012- 1/2" RSR-200 SRB-211 ------M2XH14x2.5 14 x 2.5 M034- 3/4" RSR-200 SRB-212 ------M2XH20x1.5 20 x 1.5 M034- 3/4" RSR-200 SRB-212 ------M2XH20x2.5 20 x 2.5 M034- 3/4" RSR-200 SRB-213 ------M2XH30x1.5 30 x 1.5 M100- 1" RSR-300 SRB-315 ------M2XH30x2.5 30 x 2.5 M100- 1" RSR-400 SRB-518 ------

56 888.326.5174 • summit.com/marine Reference Low Smoke Zero Halogen Terminal Selection

Terminal Remke Burndy Thomas & Betts Panduit Cable Sizes Tubes Part # mm2 1 Hole 2 Hole 1 Hole 2 Hole 1 Hole 2 Hole Male CGB Grommet Std Barrel Std Barrel Std Barrel Std Barrel Std Barrel Long Barrel M2XCH Construction M2XCH7x1.5 7 x 1.5 M038 - 3/8" RSR-100 SRB-109 ------M2XCH7x2.5 7 x 2.5 M012- 1/2" RSR-100 SRB-110 ------M2XCH10x1.5 10 x 1.5 M012- 1/2" RSR-200 SRB-211 ------M2XCH10x2.5 10 x 2.5 M034- 3/4" RSR-200 SRB-212 ------M2XCH14x1.5 14 x 1.5 M034- 3/4" RSR-200 SRB-212 ------M2XCH14x2.5 14 x 2.5 M034- 3/4" RSR-200 SRB-213 ------M2XCH20x1.5 20 x 1.5 M100- 1" RSR-200 SRB-213 ------M2XCH20x2.5 20 x 2.5 M100- 1" RSR-300 SRB-314 ------M2XCH30x1.5 30 x 1.5 M100- 1" RSR-300 SRB-316 ------M2XCH30x2.5 30 x 2.5 M100- 1" RSR-400 SRB-518 ------FM2XAH Construction FM2XAH1x2x1.5 1 x 2 x 1.5 M038 - 3/8" RSR-100 SRB-106 ------FM2XAH1x2x0.75 1 x 2 x .75 M038 - 3/8" RSR-100 SRB-105 ------FM2XAH1x2x0.5 1 x 2 x .50 M038 - 3/8" RSR-100 SRB-105 ------FM2XAH1x3x1.5 1 x 3 x 1.5 M038 - 3/8" RSR-100 SRB-107 ------FM2XAAH Construction with O/A Aluminum Tape and Drain Wire Screen FM2XAAH2x2x1.5 2 x 2 x 1.5 M012- 1/2" RSR-100 SRB-110 ------FM2XAAH2x2x0.75 2 x 2 x .75 M038 - 3/8" RSR-100 SRB-109 ------FM2XAAH2x2x0.5 2 x 2 x .50 M038 - 3/8" RSR-100 SRB-108 ------FM2XAAH4x2x1.5 4 x 2 x 1.5 M034- 3/4" RSR-200 SRB-212 ------FM2XAAH4x2x0.75 4 x 2 x .75 M012- 1/2" RSR-100 SRB-110 ------FM2XAAH4x2x0.5 4 x 2 x .50 M012- 1/2" RSR-100 SRB-110 ------FM2XAAH6x2x1.5 6 x 2 x 1.5 M100- 1" RSR-300 SRB-315 ------FM2XAAH6x2x0.75 6 x 2 x .75 M034- 3/4" RSR-200 SRB-212 ------FM2XAAH6x2x0.5 6 x 2 x .50 M012- 1/2" RSR-200 SRB-211 ------FM2XAAH10x2x1.5 10x 2 x 1.5 M100- 1" RSR-400 SRB-518 ------FM2XAAH10x2x0.75 10 x 2 x .75 M100- 1" RSR-300 SRB-315 ------FM2XAAH10x2x0.5 10 x 2 x .50 M034- 3/4" RSR-200 SRB-213 ------FM2XAAH12x2x1.5 12 x 2 x 1.5 M100- 1" RSR-400 SRB-520 ------FM2XAAH14x2x1.5 14 x 2 x 1.5 M114- 1-1/4" RSR-400 SRB-522 ------

888.326.5174 • summit.com/marine 57 Reference Low Smoke Zero Halogen Gland Selection

Cable Sizes CMP Non Hazardous CMP Hazardous Location Hawke Part # mm2 Metric Gland Part # NPT Gland Part # Gland Part # NPT M2X Construction M2X1x25 1 x 25 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2X1x35 1 x 35 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2X1x50 1 x 50 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/A 3/4" / 1" M2X1x70 1 x 70 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/A 3/4" / 1" M2X1x95 1 x 95 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/A 3/4" / 1" M2X1x120 1 x 120 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/A 3/4" / 1" M2XH Construction M2XH2x1.5 2 x 1.5 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA731 121/O 1/2" M2XH2x2.5 2 x 2.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2” M2XH2x4 2 x 4 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2XH2x6 2 x 6 M25 25A2F1RA733 3/4" 20SPXSS2K1RA731 121/A 3/4" / 1" M2XH3x1.5 3 x 1.5 M20 20SA2F1RA731 1/2” 20SPXSS2K1RA731 121/O 1/2" M2XH3x2.5 3 x 2.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2XH3x4 3 x 4 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2XH3x6 3 x 6 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/A 3/4" / 1" M2XH3x10 3 x 10 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" M2XH3x16 3 x 16 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XH3x25 3 x 25 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XH3x35 3 x 35 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4 / 1" M2XH3x50 3 x 50 M40 40A2F1RA734 1-1/4" 40PXSS2K1RA734 121/C2 1-1/2" / 1-1/4" M2XH3x70 3 x 70 M50 50SA2F1RA735 1-1/2" 50SPXSS2K1RA735 121/D 2" / 1-1/2" M2XH3x95 3 x 95 M50 50A2F1RA736 2" 50SPXSS2K1RA735 121/D 2" / 1-1/2" M2XH3x120 3 x 120 M63 63SA2F1RA736 2" 50PXSS2K1RA736 121/E 2-1/2" / 2" M2XH3x150 3 x 150 M63 63SA2F1RA736 2" 63SPXSS2K1RA736 121/E 2-1/2" / 2" M2XH3x185 3 x 185 M63 63A2F1RA737 2-1/2" 63PXSS2K1RA737 121/E 2-1/2" / 2" M2XH4x1.5 4 x 1.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2XH4x2.5 4 x 2.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" M2XH4x4 4 x 4 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/B 1" / 3/4" M2XH4x6 4 x 6 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" M2XH4x10 4 x 10 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4” M2XH4x16 4 x 16 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XH4x25 4 x 25 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XH4x35 4 x 35 M40 40A2F1RA734 1-1/4" 40PXSS2K1RA734 121/C2 1-1/2" / 1-1/4" M2XH4x50 4 x 50 M50 50SA2F1RA735 1-1/2" 50SPXSS2K1RA735 121/D 2" / 1-1/2" M2XH4x70 4 x 70 M50 50A2F1RA736 2" 50SPXSS2K1RA735 121/D 2" / 1-1/2" M2XH4x95 4 x 95 M50 50A2F1RA736 2" 50PXSS2K1RA736 121/D 2" / 1-1/2" M2XH4x120 4 x 120 M63 63SA2F1RA736 2" 63SPXSS2K1RA736 121/E 2-1/2" / 2" M2XH4x150 4 x 150 M63 63A2F1RA737 2-1/2" 63PXSS2K1RA737 121/E 2-1/2" / 2" M2XH4x185 4x 185 M75 75SA2F1RA737 2-1/2" 75SPXSS2K1RA737 121/F 3" / 2-1/2" M2XH7x1.5 7 x 1.5 M25 25A2F1RA733 3/4" 20SPXSS2K1RA731 121/B 1" / 3/4" M2XH7x2.5 7 x 2.5 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/B 1" / 3/4" M2XH10x1.5 10 x 1.5 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" M2XH10x2.5 10 x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XH14x1.5 14 x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XH14x2.5 14 x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XH20x1.5 20 x 1.5 M25 32A2F1RA733 3/4" 25PXSS2K1RA732 121/C 1-1/4" / 1" M2XH20x2.5 20 x 2.5 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XH30x1.5 30 x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XH30x2.5 30 x 2.5 M40 40A2F1RA734 1-1/4" 32LPXSS2K1RA733 121/C2 1-1/2"/1-1/4"

58 888.326.5174 • summit.com/marine Reference Low Smoke Zero Halogen Gland Selection

Cable Sizes CMP Non Hazardous CMP Hazardous Location Hawke Part # mm2 Metric Gland Part # NPT Gland Part # Gland Part # NPT M2XCH Construction M2XCH7x1.5 7 x 1.5 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/B 1" / 3/4" M2XCH7x2.5 7 x 2.5 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" M2XCH10x1.5 10 x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XCH10x2.5 10 x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XCH14x1.5 14 x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XCH14x2.5 14 x 2.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" M2XCH20x1.5 20 x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XCH20x2.5 20 x 2.5 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XCH30x1.5 30 x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" M2XCH30x2.5 30 x 2.5 M40 40A2F1RA734 1-1/4" 32LPXSS2K1RA733 121/C2 1-1/2" / 1-1/4" FM2XAH Construction FM2XAH1x2x1.5 1 x 2 x 1.5 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA731 121/O 1/2" FM2XAH1x2x0.75 1 x 2 x .75 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA731 121/O 1/2" FM2XAH1x2x0.5 1 x 2 x .50 M20 20SA2F1RA731 1/2" 20S16PXSS2K1RA731 121/0S 1/2" FM2XAH1x3x1.5 1 x 3 x 1.5 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" FM2XAAH Construction with O/A Aluminum Tape and Drain Wire Screen FM2XAAH2x2x1.5 2 x 2 x 1.5 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" FM2XAAH2x2x0.75 2 x 2 x .75 M25 25A2F1RA733 3/4" 20PXSS2K1RA731 121/B 1" / 3/4" FM2XAAH2x2x0.5 2 x 2 x .50 M20 20SA2F1RA731 1/2" 20SPXSS2K1RA731 121/O 1/2" FM2XAAH4x2x1.5 4 x 2 x 1.5 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" FM2XAAH4x2x0.75 4 x 2 x .75 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" FM2XAAH4x2x0.5 4 x 2 x .50 M25 25A2F1RA733 3/4" 20LPXSS2K1RA731 121/B 1" / 3/4" FM2XAAH6x2x1.5 6 x 2 x 1.5 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" FM2XAAH6x2x0.75 6 x 2 x .75 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" FM2XAAH6x2x0.5 6 x 2 x .50 M25 25A2F1RA733 3/4" 25PXSS2K1RA732 121/B 1" / 3/4" FM2XAAH10x2x1.5 10x 2 x 1.5 40PXSS2K1RA734 FM2XAAH10x2x0.75 10 x 2 x .75 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1" FM2XAAH10x2x0.5 10 x 2 x .50 M32 32A2F1RA733 1" 32PXSS2K1RA733 121/C 1-1/4" / 1” FM2XAAH12x2x1.5 12 x 2 x 1.5 M40 40A2F1RA734 1-1/4" 40PXSS2K1RA734 121/C2 1-1/2" / 1-1/4’ FM2XAAH14x2x1.5 14 x 2 x 1.5 M40 40A2F1RA734 1-1/4" 40PXSS2K1RA734 121/C2 1-1/2" / 1-1/4"

888.326.5174 • summit.com/marine 59 Reference Marine Cable Ampacity Guides

Low Smoke Zero Halogen Cable Size Conversion and Ampacities Size Ampacity

AWG/ mm2 Single Conductor Two Conductors at 90°C 3 or 4 Conductors at 90°C kcmil

1.5 16 22 18 15 2.5 14 31 25 21 4 12 42 34 28 6 10 53 43 35 10 8 74 60 49 16 6 99 80 66 25 4 132 107 88 35 2 160 130 107 50 1/0 198 161 133 70 2/0 248 201 166 95 4/0 303 246 203 120 250 352 286 236 150 300 402 326 269 185 400 457 371 306

Type T/N, Power/Distribution Cable, Multiconductor, 600/1000 Volts Type T/N, Control Cable, 600/1000 Volts DRILMAR™ 90 Polyvinyl Chloride/Nylon Insulated DRILMAR™ 90, Polyvinyl Chloride/Nylon Insulated

Ampacity Ampacity* Number of AWG/kcmil 2 Conductors 3 Conductors 4 Conductors Conductors 18 AWG 16 AWG 14 AWG 12 AWG 10 AWG at 90°C* at 90°C* at 90°C** 90°C 90°C 90°C 90°C 90°C 14 27 24 19 2 13 18 27 36 46 12 36 29 23 3 11 15 24 29 38 10 46 38 30 4 9 12 19 23 30 8 60 48 38 5 9 12 19 23 30 6 79 65 52 6 9 12 19 23 30 5 92 75 60 7 8 11 17 20 27 4 101 83 66 8 8 11 17 20 27 2 137 111 89 9 8 11 17 20 27 1 161 131 105 10 6 8 12 15 19 1/0 183 150 120 12 6 8 12 15 19 2/0 233 173 138 14 6 8 12 15 19 3/0 245 201 161 16 6 8 12 15 19 4/0 284 232 186 18 6 8 12 15 19 250 316 259 207 19 6 8 12 15 19 300 354 290 232 20 6 8 12 15 19 350 387 317 254 22 5 7 11 13 17 400 419 342 274 24 5 7 11 13 17 500 479 393 314 30 5 7 11 13 17 600 539 440 352 37 4 6 10 12 15 750 602 494 395 44 4 5 8 10 13 * Ampacities based on IEEE Std. 45-2002, Table 25, single bank per hanger 45 4 5 8 10 13 at 45°C ambient. Ampacities for other ambient and conductor temperature 60 4 5 8 10 13 values were calculated per IEEE-835-1994, paragraph 3.4 91 4 5 8 10 13 ** Ampacities based on IEEE Std. 45-2002, Table 25, single bank per hanger * Ampacities based on IEEE Std. 45, Table 25, at 45°C ambient. Adjustments for number of conductors were made per single bank per hanger at 45°C ambient. Note on IEEE Std. 45-2002 Table 25. Source: CME Wire and Cable. Reprinted with permission. Source: CME Wire and Cable. Reprinted with permission.

60 888.326.5174 • summit.com/marine Reference Marine Cable Ampacity Guides

Type P, Power/Distribution Cable, Single Conductor, 600/1000/2000 Volts DRILMAR™ 125-XE, Crosslinked Polyolefin Insulated/CP Jacket

Ampacity* AWG/kcmil 125°C 110°C 100°C 95°C 18 19 17 16 15 16 27 25 23 22 14 43 40 37 36 12 52 48 45 43 10 67 62 58 56 8 84 77 72 69 6 112 103 96 92 5 127 117 109 105 4 149 137 128 123 2 197 181 169 162 1 226 208 194 186 1/0 264 243 227 218 2/0 305 281 262 252 3/0 349 321 300 288 4/0 408 376 351 337 262 473 436 407 391 313 529 487 455 437 373 600 553 516 496 444 684 630 588 565 535 733 675 630 605 646 850 783 731 702 777 956 881 822 790 1111 1192 1098 1025 985 * Ampacities based on IEEE Std. 45-2002, single bank per hanger at 45°C ambient. Ampacities for other ambient and conductor temperature values were calculated per IEEE-835-1994, paragraph 3.4 Correction Factors (Ambient in SIngle Bank per IEEE 45) Derate Factor For 125°C @ 45°C 110°C @ 45°C 100°C @ 45°C 95°C @ 45°C

1) Double Bank 0.8 0.8 0.8 0.8 2) 50°C Ambient 0.97 0.96 0.95 0.95 3) 55°C Ambient 0.94 0.92 0.90 0.89 4) 40°C Ambient 1.03 1.04 1.04 1.05

Source: CME Wire and Cable. Reprinted with permission.

888.326.5174 • summit.com/marine 61 Reference

Type P, Power/Distribution Cable, Multiconductor, 600/1000 Volts DRILMAR™ 125-XE, Crosslinked Polyolefin Insulated/CP Jacket

Ampacity AWG/ 2 Conductors* 3 Conductors* 4 and 5 Conductors** kcmil 125°C 110°C 100°C 95°C 125°C 110°C 100°C 95°C 125°C 110°C 100°C 95°C 18 16 15 14 13 14 13 12 12 11 11 10 9 16 22 20 19 18 19 17 16 15 15 14 13 12 14 36 33 31 30 29 27 25 24 23 21 20 19 12 47 43 40 38 36 33 31 30 29 27 25 24 10 57 52 49 47 48 44 41 39 38 35 33 32 8 74 69 64 61 60 56 52 50 48 45 42 40 6 99 91 85 82 81 75 70 67 65 60 56 54 5 117 108 101 97 95 88 82 79 76 71 66 63 4 128 118 110 106 107 99 92 88 86 79 74 71 2 173 160 149 143 142 131 122 117 114 105 98 94 1 202 186 174 167 166 153 143 137 133 122 114 110 1/0 231 213 199 191 191 176 164 158 153 140 131 126 2/0 282 259 242 232 219 201 188 181 175 161 150 144 3/0 308 284 265 255 254 234 218 209 203 186 174 168 4/0 357 329 307 295 293 270 252 242 235 216 202 194 262 416 383 358 344 342 315 294 282 274 252 235 226 313 455 419 391 376 373 344 321 308 299 275 257 247 373 514 473 442 425 420 387 361 347 336 310 289 277 444 586 540 504 484 478 440 411 395 382 352 329 316 535 626 576 538 517 515 475 443 426 412 380 354 340 646 735 677 632 607 600 553 516 496 480 442 413 397 777 796 733 684 657 654 602 562 540 523 482 450 432 * Ampacities based on IEEE Std. 45-2002, Table 25, single bank per hanger at 45°C ambient. Ampacities for other ambient and conductor temperature values were calculated per IEEE-835-1994, paragraph 3.4

** Ampacities based on IEEE Std. 45-2002, Table 25, single bank per hanger at 45°C ambient. Ampacities for number or conductors were made per Note on IEEE std. 45-2002 Table 25.

Source: CME Wire and Cable. Reprinted with permission.

The Tool Every Electrician Needs. Formulas, tables, charts and diagrams that you can use every day on every job. Now updated for the 2011 NEC®.

Learn more at summit.com/refbook

62 888.326.5174 • summit.com/marine Reference

Type P, Control Cable, 600/1000 volts DRILMAR™ 125-XE, Crosslinked Polyolefin Insulated

Ampacity*

Number of Conductors 20 AWG 18 AWG 16 AWG

95°C 100°C 110°C 125°C 95°C 100°C 110°C 125°C 95°C 100°C 110°C 125°C 2 10 10 11 12 13 14 15 16 18 19 20 22 3 9 9 10 10 12 12 13 14 15 16 17 19 4 7 7 8 8 9 10 10 11 12 13 14 15 5 7 7 8 8 9 10 10 11 12 13 14 15 6 7 7 8 8 9 10 10 11 12 13 14 15 7 6 6 7 7 8 8 9 10 11 11 12 13 8 6 6 7 7 8 8 9 10 11 11 12 13 9 6 6 7 7 8 8 9 10 11 11 12 13 10 4 5 5 5 6 6 6 7 8 8 9 9 12 4 5 5 5 6 6 6 7 8 8 9 9 14 4 5 5 5 6 6 6 7 8 8 9 9 16 4 5 5 5 6 6 6 7 8 8 9 9 18 4 5 5 5 6 6 6 7 8 8 9 9 19 4 5 5 5 6 6 6 7 8 8 9 9 20 4 5 5 5 6 6 6 7 8 8 9 9 22 4 4 4 5 5 5 6 6 7 7 8 8 24 4 4 4 5 5 5 6 6 7 7 8 8 30 4 4 4 5 5 5 6 6 7 7 8 8 37 3 4 4 4 5 5 5 6 6 6 7 7 44 3 3 3 4 4 4 4 5 5 6 6 7 45 3 3 3 4 4 4 4 5 5 6 6 7 60 3 3 3 4 4 4 4 5 5 6 6 7 91 3 3 3 4 4 4 4 5 5 6 6 7 Ampacity*

Number of Conductors 14 AWG 12 AWG 10 AWG

95°C 100°C 110°C 125°C 95°C 100°C 110°C 125°C 95°C 100°C 110°C 125°C 2 30 31 33 36 38 40 43 47 47 49 52 57 3 24 25 27 29 30 31 33 36 39 41 44 48 4 19 20 21 23 24 25 27 29 32 33 35 38 5 19 20 21 23 24 25 27 29 32 33 35 38 6 19 20 21 23 24 25 27 29 32 33 35 38 7 17 18 19 20 21 22 23 25 28 29 31 33 8 17 18 19 20 21 22 23 25 28 29 31 33 9 17 18 19 20 21 22 23 25 28 29 31 33 10 12 13 13 15 15 16 17 18 20 21 22 24 12 12 13 13 15 15 16 17 18 20 21 22 24 14 12 13 13 15 15 16 17 18 20 21 22 24 16 12 13 13 15 15 16 17 18 20 21 22 24 18 12 13 13 15 15 16 17 18 20 21 22 24 19 12 13 13 15 15 16 17 18 20 21 22 24 20 12 13 13 15 15 16 17 18 20 21 22 24 22 11 11 12 13 13 14 15 16 18 18 20 21 24 11 11 12 13 13 14 15 16 18 18 20 21 30 11 11 12 13 13 14 15 16 18 18 20 21 37 10 10 11 12 12 12 13 14 16 16 18 19 44 8 9 9 10 10 11 12 13 14 14 15 17 45 8 9 9 10 10 11 12 13 14 14 15 17 60 8 9 9 10 10 11 12 13 14 14 15 17 91 8 9 9 10 10 11 12 13 14 14 15 17 * Ampacities based on IEEE Std. 45-2002, Table 25, single bank per hanger at 45°C ambient

Source: CME Wire and Cable. Reprinted with permission.

888.326.5174 • summit.com/marine 63 Reference

Certifying Bodies

American Bureau of Shipping (ABS)

Bureau Veritas (BV)

Det Norske Veritas (DNV)

Germanischer Lloyd (GL)

Lloyd’s Register (LR)

Class NK (Nippon Kaiji Kyokai)

Registro Italiano Navale (RINA)

Russian Maritime Register of Shipping (RMRS)

Türk Loydu (Turkish Lloyd)

64 888.326.5174 • summit.com/marine Index of Manufacturers In addition to wire and cable, Summit’s Marine Division offers a full array of marine electrical products.

Audio / Visual Signals Conduit Fittings Instruments Shipboard Navigation Lights Sirens / Bells / Horns / Signal Lights Malleable / Cast / Aluminum / Steel Voltage / Amperes / Continuity USCG Approved / Single / Dual Lamp Federal Signal Cooper Crouse-Hinds Fluke Aqua Signal Thomas & Betts Greenlee Ballasts Shipboard Wiring Devices Cast Alumimum Fluorescent / HID Labels / Markers /Signs Switch / Receptacle / Junctions Cooper Crouse-Hinds Universal Lighting Technologies Cable Marking / Safety Marking Phoenix Plastic Coated Panduit Banding Plastibond Hayata Switch / Receptacle & Related Devices 316 SS Banding / Buckles Die Cast Steel Weidmuller Cooper Wiring Devices Hayata Cooper Crouse-Hinds Coated 316 SS Banding / Buckles Lamps Strut Systems Conduit Hubs Hayata Incandescent / Fluorescent / HID Slotted / Angled Cast / Steel / Aluminum / SS Sylvania Cooper B-Line Batteries Cooper Crouse-Hinds / Myers Miniature Kindorf Industrial AAA / AA / C / D / Trans / Cord Grips Sunray Lantern Tapes Aluminum Gland Type Grip Rayovac Motor Control Insulating / Bonding / Color Coding Remke Shipboard Battery Systems / MCC / Enclosed Control 3M Nylon Gland Type Grip Flooded and Gel Cell Eaton (Cutler-Hammer) Kleinhuis (Niedax) Terminal Blocks Interstate Batteries Westinghouse Din Rail Mount Crane Control Military Spec. Navy Control / Parts Cable Glands Weidmuller Crane Brake Parts Eaton (Cutler-Hammer Navy) Marine / Industrial General Duty Eaton (Cutler-Hammer) Terminal Tubes Gland Navigation Light Panels 1/2 - 4 Mil Spec. Nylon CMP Distribution Gear USCG Approved Custom Panels Dorn Hawke Panel Boards / Power Distribution J - Box 1/2 - 4 Brass / Aluminum / Male / Marine / Industrial Class 1, Eaton (Cutler-Hammer) Pin & Sleeve Plug & Receptacle Female Division 1 & 2 Gland Westinghouse 20 - 400 Amp / Aluminum Summit Electric Supply CMP Military Spec. Navy Breakers / Cooper Crouse-Hinds Hawke Shock & Vibration Terminals / Lugs 20 - 400 Amp / Nylon Eaton (Cutler-Hammer) Mechanical / Compression Cable Termination Stahl Westinghouse Panduit 250V / 600V / High Voltage Portable Cord Burndy Panduit Electricians’ Supplies SO / SEOW / Type W / GGC Thomas & Betts Raychem Hand Tools Southwire Thomas & Betts Klein Tools Timers Ideal Portable Cord Sets & Parts Electronic / Mechanical Timers Cable Tray Cord Caps / Cord Sets Tork Steel / Aluminum / Marine Rung Emergency Lighting Woodhead B-Line Battery Operated Transformers Hubbell Niedax Teledyne / Big Beam Marine Duty Dry Type 25kVa - Fiberglass Ladder Chloride Portable Lighting 500kVa Chalfant Dual Lite Hand Lamps / Class 1 Division 1 / Eaton (Cutler-Hammer) Excide Safety Systems Non Hazard Westinghouse Cables / Industrial Woodhead Dry Type and Oil Filled / SS Clad MV 90 / IAC / CLX / Control / Enclosures Portable Lights Olsun Instrumentation NEMA / Steel / Aluminum / SS Worklights Inc. Oil Filled / SS Clad Okonite Cooper Crouse-Hinds Van Tran MV 90 / IAC / Control / Hoffman Safety Switches Control Power Instrumentation / DLO NEMA / Fiberglass 30 -1200 Amp. / General / Eaton (Cutler-Hammer) Southwire Hoffman Heavy Duty Machine Tool MV 90 / IAC / Control / Eaton (Cutler-Hammer) Acme Transformer Flashlights Instrumentation / Welding / DLO Dry Type Distribution Mini / D Cell / Lantern Shipboard Cable Hanger AIW Acme Transformer Control / Instrumentation / Rayovac Commercial Cable Hanging Systems Fiber Optic / IAC Bright Star R. T. & D Transit Barriers / MCTs Kindorf Multi Diameter / Fire / Water / Belden Fuses Victor Gas Rated Glass / 250V / 600 V / High Voltage Caulking Commercial and Military Spec Roxtec Mersen (Ferraz Shawmut) Silicone Systems European Fuses GE Plastics R. T. & D Tyraps USCG Approved Fire Stop Caulk Mersen (Ferraz Shawmut) Wire Securing Devices, Nylon & SS Shipboard Communication Panduit Nelson Grounding Systems Integrated Ship Communications Hayata Rods and Fittings Chemicals Federal Signal Safety and Thomas & Betts Cadweld Wire Lube / Cleaners Security Systems Wire Connectors Ideal Heat Shrink Tubing Sound Powered Phones Wire Nuts Lubricants / Cleaners / Solvents Thick / Thin Wall Tubing Hose McCann Ideal CRC Panduit Shipboard General Alarm Wing Nuts 3M Conduit USCG / Navy Approved Brass Bells 3M Raychem Rigid Galvanized Steel Hose McCann Wiring Devices LTV Industrial Lighting Fixtures General Alarm Panels Switches / Receptacles Shamrock Incandescent / Fluorescent / HID J-Box Cooper Wiring Devices Allied Cooper Crouse-Hinds Shipboard Light Fixtures Woodhead Rigid Stainless Steel Phoenix Incandescent / Fluorescent / HID / Gibson Fluorescent Bronze / Aluminum / SS Rigid Aluminum Mobern Easco Phoenix Industrial Reelites Indalex Incandescent / Fluorescent / HID / Electrical / Pneumatic Plastic Coated Aluminum / SS Cooper Crouse-Hinds Plastibond Aqua Signal Sealtight L.C. Doane Anaconda IRL Flexible Anaconda

888.326.5174 • summit.com/marine 888.326.5174 • summit.com/marine Marine Division

888.326.5174 • summit.com/marine