Medium Voltage Cable

Total Page:16

File Type:pdf, Size:1020Kb

Medium Voltage Cable Medium Voltage Cable A Marmon Wire & Cable / Berkshire Hathaway Company hendrix-wc.com kerite.com hendrix-wc.com kerite.com TABLE OF CONTENTS Introduction .................................................................................................................................................................... 2 Hendrix Product Information .................................................................................................................................... 4 Underground Residential Distribution Cables (URD) 15kV ...................................................................................................................................................................6 25kV ................................................................................................................................................................ 10 35kV .................................................................................................................................................................12 Electrical Data ...............................................................................................................................................14 Kerite Product Information........................................................................................................................................18 Underground Residential Distribution Cables (URD) 15kV ................................................................................................................................................................ 20 25kV ................................................................................................................................................................22 35kV ................................................................................................................................................................24 URD Ampacities ..........................................................................................................................................26 Power Cables 5kV ................................................................................................................................................................... 27 15kV .................................................................................................................................................................28 25kV ................................................................................................................................................................29 35kV ............................................................................................................................................................... 30 Compact Power Cable 15kV, 25kV, 35kV ............................................................................................................................................31 5-35kV Cable Ampacities ................................................................................................................................... 32 Ampacity Calculation Notes .............................................................................................................................. 34 1 Hendrix-Kerite Power Cable Introduction Hendrix-Kerite Power Cable Hendrix-Kerite Power Cable supplies medium-voltage, primary cable to the electric utility market. The Power Cable business unit markets through two highly respected industry- recognized brands. • Hendrix Wire & Cable manufactures TRXLPE-insulated, medium voltage cables, rated 15kV to 35kV in the Milford, NH location. • The Kerite Company manufactures specialized, EPR insulated, medium voltage cables, rated 5kV to 35kV and PILC replacement cable in the Seymour, CT location. Hendrix-Kerite Power Cable is part of Marmon Utility LLC. Marmon Utility LLC is comprised of six separate business units that serve the electric utility, contractor and petroleum markets: • Hendrix-Kerite Power Cable • Hendrix Aerial Cable Systems • Hendrix Molded Products • Kerite Cable Services • Kerite High Voltage and Specialty Cable • Kerite Pump Cable Marmon Utility LLC is part of the Marmon Engineered Wire & Cable Division. This division is just one of many business segments of The Marmon Group. The Marmon Group is an international association of manufacturing and service companies that operate independently. It is made up of 11 diverse stand-alone business sectors. These business sectors operate approximately 300 manufacturing, distribution and service facilities. The Marmon Group employs more than 17,000 employees world-wide. In 2008, The Marmon Group was acquired by Berkshire Hathaway. Berkshire Hathaway is one of the largest holding companies in the world, employing over 270,000 people in a wide array of businesses globally. Berkshire has significant involvement in industries such as; insurance, railroad and tank cars, retail sales, home construction, furniture, petrochemicals, utilities, water treatment, wire & cable. Berkshire provides capital, legal and tax services to The Marmon Group and its other companies. 2 Hendrix-Kerite Power Cable When you need it now... Cable Prospector Kerite EPR and Hendrix TR-XLPE URD Cable Inventory - Cable Prospector (CPX) gives you 24/7 access to Marmon Utility LLC's (Hendrix and Kerite) on hand available inventory of MV Underground & Aerial (Overhead) Power Distribution Cable. All manufactured to ICEA and original utility customer specifications, available for immediate shipment anywhere in the USA. https://www.cableprospector.com/ Hendrix Wire & Cable has manufactured electrical cable products for the utility industry since 1951. The first products produced by Hendrix were patented overhead spacers and polymer insulators. Since 1967, Hendrix has manufactured medium-voltage, underground cable. Hendrix is a leader in promoting electrical test requirements in the industry and in other quality advancements such as clean room technology. It has built a reputation for high quality cable, short, consistent leadtimes and responsive customer service. Hendrix underground cable is produced in a 250,000 sq. feet plant located in Milford, NH. Hendrix is vertically integrated to fabricate bare aluminum and copper conductor used in the manufacture of utility cables. True-triple, gas-cure, primary extrusion lines are fully supported by neutral and jacket machines. Electrical and physical test facilities perform all standard industry tests. In addition, an analysis lab handles qualification testing, compound development, and failure analysis for customers. The Kerite Company manufactures aluminum and copper conductor cables with EPR insulation. It has manufactured underground distribution cables since 1926 and subsea cable since the late 1800s. Like Hendrix, Kerite produces cables for the electric utility market. The underground products range from 5kV through 138kV. Kerite utilizes a proprietary cable design for its utility cable. The basic design is a unique discharge-resistant insulation system that is field proven and has the longest warranty in the industry. Both Hendrix and Kerite market cable through a national network of manufacturers representatives. 3 Hendrix-Kerite Power Cable Product Information Hendrix Wire & Cable, Inc. 53 Old Wilton Road Milford, NH 03055 603.673.2040 603.249.1367 [email protected] www.hendrix-wc.com 4 Hendrix Power Cable • hendrix-wc.com Underground Residential Distribution Cable Hendrix distribution cable comes in voltages ranging from 15kV thru 35kV for use in underground residential distribution applications. Conductor Insulation System Shielding Jacket • Copper • 100% Level • Concentric Neutrals • Polyethylene (PE) - Stranded - TRXLPE - Bare • Markings - Filled • 133% Level - Full, One-Third or - Marker Stripes • Aluminum - TRXLPE Custom Design - Sequential Footage - Solid - Phase Identifi cation - Stranded - NESC Direct Buried Identifi er - Filled 5 Hendrix Power Cable • hendrix-wc.com UNDERGROUND RESIDENTIAL DISTRIBUTION CABLE (15kV) Underground Distribution Cable (URD) 15kV Aluminum Conductor 90°C • Conductor Shield – Semi-Conducting Layer (100% – .175") • Insulation – TRXLPE Concentric Insulation Conductor Jacket Wires Shield Shield Insulation Shield – Semi-Conducting EzStrip® Layer • Insulation • Concentric Wires – One-third and Full Neutral Conductor Jacket – Non-Conducting Polyethylene (LLDPE) with 3 Hendrix URD Cable – 15kV URD Cable Hendrix • Red Stripes, Semi-Conducting Available Copper Diameter * Conductor Weights (lbs/ft) Neutral (per ANSI/ICEA S-94-649) Aluminum Number Number Over Total Total With AWG or Size Min. Over Max. Over of of Conductor Embedded Conductor Neutral Without Embedded kcmil AWG Insulation Insulation Strands Wires Jacket Jacket Jacket 2 SOLID 10 14 0.258 0.610 0.695 0.960 0.0611 0.130 0.356 0.477 2 7 10 14 0.283 0.635 0.720 0.990 0.0623 0.130 0.370 0.487 1 SOLID 13 14 0.289 0.645 0.725 0.995 0.0785 0.173 0.424 0.543 1 19 13 14 0.322 0.675 0.760 1.015 0.0785 0.173 0.437 0.556 Full 1/0 SOLID 16 14 0.325 0.680 0.760 1.030 0.0972 0.210 0.494 0.615 Neutral 1/0 19 16 14 0.362 0.715 0.800 1.055 0.0991 0.210 0.510 0.632 2/0 19 13 12 0.406 0.760 0.845 1.100 0.1249 0.276 0.616 0.760 3/0 19 16 12 0.456 0.810 0.895 1.170 0.1575 0.340 0.730 0.874 4/0 19 20 12 0.512 0.865 0.950 1.235 0.1986 0.425 0.875 1.030 1/0 SOLID 6 14 0.325 0.680 0.760 1.030 0.0972 0.080 0.356 0.460 1/0 19 6 14 0.362 0.715 0.800 1.055 0.0991 0.080 0.373 0.515 2/0 19 7 14 0.406 0.760 0.845 1.100 0.1249 0.094 0.434 0.575
Recommended publications
  • Offshore Wind Submarine Cable Spacing Guidance
    Offshore Wind Submarine Cable Spacing Guidance Contract # E14PC00005 United States Department of Interior Bureau of Safety and Environmental Enforcement December 2014, For Public Use Offshore Wind Submarine Cable Spacing Guidance Contract # E14PC00005 United States Department of Interior Bureau of Safety and Environmental Enforcement December 2014, For Public Use The authors gratefully acknowledge permission of the Crown Estate to base parts of this report on their study “Principles of Cable Routing and Spacing (2012)”, Reference ID 8 in this report Document Control Responsible for Job Title Name Date Signature Chris Sturgeon Cables specialist Jim Hodder Cables specialist Colin Poat Cables specialist Content 2014-12-15 Cables specialist Steven Drew Principal Environmental Consultant Rachel McCall EHS Senior Consultant Tanjia Maynard Checked EHS Senior Consultant Tanjia Maynard 2014-12-15 Approval Principal Engineer Jim Doane 2014-12-15 Copyright: PMSS © Document Reference: 734300670/140708 Signatures in this approval box have checked this document in line with the requirements of QP16 This report has been prepared by TÜV SÜD PMSS and Red Penguin Associates with all reasonable skill and care, within the terms of the contract with the Client. The report contains information from sources and data which we believe to be reliable but we have not confirmed that reliability and make no representation as to their accuracy or completeness. The draft report is confidential to the Client and TÜV SÜD PMSS accepts no responsibility to any third party to whom information in this report may be disclosed. No part of this document may be reproduced without the prior written approval of TÜV SÜD PMSS © TÜV SÜD PMSS 2014 Offshore Wind Submarine Cable Spacing Guidance 1 Bureau of Safety and Environmental Enforcement Table of Contents Abbreviations 2 1.
    [Show full text]
  • Offshore Wind Submarine Cabling Overview Fisheries Technical Working Group
    OFFSHOREoverview WIND SUBMARINE CABLING Fisheries Technical Working Group Final Report | Report Number 21-14 | April 2021 NYSERDA’s Promise to New Yorkers: NYSERDA provides resources, expertise, and objective information so New Yorkers can make confident, informed energy decisions. Our Vision: New York is a global climate leader building a healthier future with thriving communities; homes and businesses powered by clean energy; and economic opportunities accessible to all New Yorkers. Our Mission: Advance clean energy innovation and investments to combat climate change, improving the health, resiliency, and prosperity of New Yorkers and delivering benefits equitably to all. Courtesy, Equinor, Dudgeon Offshore Wind Farm Offshore Wind Submarine Cabling Overview Fisheries Technical Working Group Final Report Prepared for: New York State Energy Research and Development Authority Albany, NY Morgan Brunbauer Offshore Wind Marine Fisheries Manager Prepared by: Tetra Tech, Inc. Boston, MA Brian Dresser Director of Fisheries Programs NYSERDA Report 21-14 NYSERDA Contract 111608A April 2021 Notice This report was prepared by Tetra Tech, Inc. in the course of performing work contracted for and sponsored by the New York State Energy Research and Development Authority (hereafter “NYSERDA”). The opinions expressed in this report do not necessarily reflect those of NYSERDA or the State of New York, and reference to any specific product, service, process, or method does not constitute an implied or expressed recommendation or endorsement of it. Further, NYSERDA, the State of New York, and the contractor make no warranties or representations, expressed or implied, as to the fitness for particular purpose or merchantability of any product, apparatus, or service, or the usefulness, completeness, or accuracy of any processes, methods, or other information contained, described, disclosed, or referred to in this report.
    [Show full text]
  • Analysis and Study the Performance of Coaxial Cable Passed on Different Dielectrics
    International Journal of Applied Engineering Research ISSN 0973-4562 Volume 13, Number 3 (2018) pp. 1664-1669 © Research India Publications. http://www.ripublication.com Analysis and Study the Performance of Coaxial Cable Passed On Different Dielectrics Baydaa Hadi Saoudi Nursing Department, Technical Institute of Samawa, Iraq. Email:[email protected] Abstract Coaxial cable virtually keeps all the electromagnetic wave to the area inside it. Due to the mechanical properties, the In this research will discuss the more effective parameter is coaxial cable can be bent or twisted, also it can be strapped to the type of dielectric mediums (Polyimide, Polyethylene, and conductive supports without inducing unwanted currents in Teflon). the cable. The speed(S) of electromagnetic waves propagating This analysis of the performance related to dielectric mediums through a dielectric medium is given by: with respect to: Dielectric losses and its effect upon cable properties, dielectrics versus characteristic impedance, and the attenuation in the coaxial line for different dielectrics. The C: the velocity of light in a vacuum analysis depends on a simple mathematical model for coaxial cables to test the influence of the insulators (Dielectrics) µr: Magnetic relative permeability of dielectric medium performance. The simulation of this work is done using εr: Dielectric relative permittivity. Matlab/Simulink and presents the results according to the construction of the coaxial cable with its physical properties, The most common dielectric material is polyethylene, it has the types of losses in both the cable and the dielectric, and the good electrical properties, and it is cheap and flexible. role of dielectric in the propagation of electromagnetic waves.
    [Show full text]
  • Drop Cable Construction Manual
    Construction manual Broadband applications and construction manual Drop cable products Contents Introduction 3 Description of cable types 5 Cable selection guide 6 Planning the run 12 Aerial installation 13 Buried installation 16 Attaching to the ground block per NEC 830 19 Attaching to the NIU per NEC 830 20 Residential interior cabling 22 Multiple dwelling units (MDUs) 28 Commercial installations 31 Drop cable descriptions/specifications 32 Appendix 33 Broadband resource center 36 commscope.com 2 How to use this guide The drop cable applications and construction guide is written for the cable installation professional who, due to the diverse services offered by CATV and telecommunication service providers, needs a quick and handy reference to practical installation information, especially in the case of retrofitting. We’ve tried to simplify the decision-making process as to which cables to choose for what installation, taking into account factors such as performance over distance, preventing RF interference and fire/safety codes. We also want to introduce you to some products that may ease some of your installation headaches, such as BrightWire® anti-corrosion treatment for braid shields, and QR® 320, an ultra-long-reach coaxial cable. One of the big changes in our industry is the introduction of powered broadband services, which are addressed in the National Electrical Code’s Article 830. This manual shows you when to use NEC 830 cables; pages 13 and 16 (aerial and buried installations) cover specific issues involving installation clearances; other chapters carry special callouts concerning NEC 830 issues. Most attention is paid to residential installations (page 22) which has the most “practical” information, especially for trim-out.
    [Show full text]
  • Wiring a Wall Section
    Youth Explore Trades Skills Electrician Wiring a Wall Section Description The activities that have led up to wiring a wall should have given students the skills and knowledge to culminate with this activity. This activity could be an opportunity to conduct a summative assessment of students’ previous knowledge of theory, safety, code, and wiring methods. Wiring a wall section will introduce students to a few new CEC rules and wiring methods. Having a wall section is obviously a requirement for this activity. The wall section could be full scale or smaller; to make this activity relate to the real world, it’s recommended that the wall section be at least 4' wide by 4' tall. The wall section shown in Figure 1 would be optimal, as it has some real (although scaled down to half size) features such as door and window openings, as well as a corner section, which will help students learn about routing wire and placement of device boxes in relation to these features. Figure 1—Sample wall section Building a wall section for a class requires a substantial amount of lumber and time. Optimally, this activity would work well with students having completed the carpentry portion of the course first. This activity is an opportunity for students to wire a wall to code specifications and with the teacher’s supervision, energize and test their circuits. Students will likely work in small groups, depending on the availability of material and the number of walls available. The students should have the opportunity to wire their wall sections individually, to give the teacher a clear picture of each student’s skills and competencies.
    [Show full text]
  • Technical Information Handbook Wire and Cable
    Technical Information Handbook Wire and Cable Fifth Edition Copyright © 2018 Trademarks and Reference Information The following registered trademarks appear in this handbook: Information in this handbook has been drawn from many Alumel® is a registered trademark of Concept Alloys, LLC publications of the leading wire and cable companies in the industry and authoritative sources in their latest available Chromel® is a registered trademark of Concept Alloys, LLC editions. Some of these include: Copperweld® is a registered trademark of Copperweld Steel Company CSA® is a registered trademark of the Canadian Standards Association • American Society for Testing and Materials (ASTM) CCW® is a registered trademark of General Cable Corporation • Canadian Standards Association (CSA) ® DataTwist is a registered trademark of Belden • Institute of Electrical and Electronics Engineers (IEEE) Duofoil® is a registered trademark of Belden Flamarrest® is a registered trademark of Belden • Insulated Cable Engineers Association (ICEA) Halar® is a registered trademark of Solvay Solexis • International Electrotechnical Commission (IEC) Hypalon® is a registered trademark of E. I. DuPont de Nemours & Company • National Electrical Manufacturers Association (NEMA) Hypot® is a registered trademark of Associated Research, Inc. • National Fire Protection Association (NFPA) IBM® is a registered trademark of International Business Machines Corporation Kapton® is a registered trademark of E. I. DuPont de Nemours & Company • Naval Ship Engineering Center (NAVSEC) Kevlar® is a registered trademark of E. I. DuPont de Nemours & Company • Telecommunications Industry Association (TIA) ® K FIBER is a registered trademark of General Cable Corporation • Underwriters Laboratories (UL). Kynar® is a registered trademark of Arkema, Inc. Loc-Trac® is a registered trademark of Alpha Wire Note: National Electrical Code (NEC) is a registered trademark of the National Fire Protection Association, Quincy, MA.
    [Show full text]
  • TPC Wire Cable Mining Industry.Pdf
    TPC WIRE & CABLE TPC WIRE & CABLE TPC WIRE & CABLE Providing the Total Wire & Cable Solution to the MINING INDUSTRY TPC WIRE & CABLE PROVIDES • High-performance problem-solving products • Cost and time-saving products for industrial applications • Personal sales support • In-depth inventories • Hard-to-find cord and cable products • Knowledgeable customer service • A safer electrical environment • Longer lasting products • Custom engineered products Electrical cord and cable is a vital link in your facility’s electrical system Electrical equipment requires quality cord and cable that can stand up to today’s industrial environments. Many cord and cable applications are subject to one or more of the following conditions: • Impact & Vibration • Oil, chemical & water deterioration • Crushing & Abrasion • Extreme heat & cold • Pulling & Flexing • Unsafe areas Too often, maintenance must use ORDINARY cord and cable in these areas because that’s all that’s available. These products do not hold up because they are not designed for maintenance environments. As you know . the real cost of cord and cable maintenance includes not only the cost of material, but also the labor and downtime that result from unnecessary repair and replacement of damaged or worn-out cord and cable. 2 TPC WIRE & CABLE TPC WIRE & CABLE TPC WIRE & CABLE Ideal for Abusive Environments Abrasion • High Heat • Chemical In the mining environment, it is important to address the abusive environments in which the electrical cable is applied. In many cases, the cable will fail due to extensive abrasion, tension, cut-through and in some instances, damage from local wildlife. Therefore, choosing a high quality, high performance electrical cable and like accessories are at the forefront to save labor, material and downtime costs.
    [Show full text]
  • 1218: Electric Service Handbook for Permanent and Temporary Service
    Addendum Electric Service Handbook: Single-Family Residential Projects Permanent and Temporary Service (Form #1218, 06/19) Update to Underground Service Information Effective Date: 11/26/19 This addendum is to clarify and correct information updated in the latest edition of this document. Chapters 2 & 5: Page 19 Customer-installed service line conduit installation requirements section, Page 51 Underground section, and page 52 Figure 33 • Conduit in the main service trench shall be 3-inch gray Schedule 40 from the PSE facility (pole/vault/handhole/pedestal) to the service riser/work pit. • The knockout on the 200-amp meter base is 2-1/2 inches in diameter. • 200-amp services should be installed with a non-continuous conduit system using 3-inch conduit in the main service trench and a 2-1/2-inch conduit service riser to the meter base knockout because of the differing pipe sizes. Reference the Electric underground service installation requirements handout (Form 6080) for work pit requirements. NOTES 1. PSE encourages customers to install 320-amp panels if the service requires 350 MCM to be installed for any portion of the service. 2. An existing panel requiring an upgrade to larger than 200 amps, or an added motor load, may require excavation and the existing conduit be replaced with a 3-inch conduit or a new 3-inch conduit installed if no conduit existed previously. • 320-amp service with continuous or non-continuous conduit shall use a 3-inch conduit from end to end of the service. Electric Service Handbook June 2021 Single-Family Residential Projects Permanent and Temporary Service ©2021 by Puget Sound Energy All rights reserved.
    [Show full text]
  • A Practical Guide Understanding and Selecting Ethernet Cable
    A Practical Guide Understanding and Selecting Ethernet Cable Peter L Hail Warehouse Cables, LLC, 1303 Jefferson Blvd, Warwick, RI 02886 [email protected] www.warehousecables.com Tel: 401.737.5677 Fax: 401.737.4677 Computer Networking is all about sharing. It means sharing information or services between local devices such as other computers, printers, external hard drives and even video distribution. It also means sharing information or services with the rest of the world via the Internet. The network highway can be wired or wireless creating enormous flexibility. In this discussion we're going to focus on the wired side, otherwise known as Ethernet cabling and connectivity. Before we get started let’s keep in mind that this is a practical guide. Many of the deeper details are omitted and more relevant to an engineering specification. So get ready, here comes the fine print… Disclaimer: Nothing in this guide should be construed as specific advice or recommendation of any kind. Your application will ultimately determine the best possible solutions. Warehouse Cables is in no way responsible for any interpretation or results thereof from the information provided herein. Bring In the Standards Ok, so who came up with this Ethernet communications scheme? The Institute of Electrical and Electronics Engineers (IEEE) published the final IEEE 802.3 standard in 1985 as a replacement for older wired LAN (local area network) technologies. The twisted pair cabling standard arrived around 1990 and has since evolved through the various “Categories” up to the present. In addition, the Telecommunications Industry Association and Electronic Industries Alliance (EIA/TIA) developed their own standards, based on IEEE 802.3 to serve the public interest by eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and promoting the improvement of products.
    [Show full text]
  • Coaxial Cable
    ANALOG ELECTRICAL and DIGITAL VIDEO FORMATS and CONNECTORS Analog Electrical Formats/Connectors Component Video Component video is a type of video information that is transmitted or stored as two or more separate signals (as opposed to composite video, such as NTSC or PAL, which is a single signal). Most component video systems are variations of the red, green and blue signals that make up a television image. The simplest type, RGB, consists of the three discrete red, green and blue signals sent down three wires. This type is commonly used in Europe through SCART connectors. Outside Europe, it is generally used for computer monitors, but rarely for TV-type applications. Another type consists of R-Y, B-Y and Y, delivered the same way. This is the signal type that is usually meant when people talk of component video today. Y is the luminance channel, B-Y (also called U or Cb) is the blue component minus the luminance information, and R-Y (also called V or Cr) is the red component minus the luminance information. Variants of this format include YUV, YCbCr, YPbPr and YIQ. In component systems, the synchronization pulses can either be transmitted in one or usually two separate wires, or embedded in the blanking period of one or all of the components. In computing, the common standard is for two extra wires to carry the horizontal and vertical components, whereas in video applications it is more usual to embed the sync signal in the green or Y component. The former is known as sync-on-green.
    [Show full text]
  • TIPS on a SUCCESSFUL HDMI OVER CAT5/6/7 INSTALLATION By
    TIPS ON A SUCCESSFUL HDMI OVER CAT5/6/7 INSTALLATION By HDTV SUPPLY, INC. (800) 841-9238 (805) 277-1870 Direct WEB: www.HDTVSupply.com SUPPORT: [email protected] Today when I Googled the term – HDMI problem – I came up with 28,700,000 pages with 10 links on each page making for over a quarter of a BILLION posts by individuals who were looking for solutions to their unique HDMI problem….again a quarter of a BILLION. Why? HDMI is not like the older plug-and-play analog VGA, component, composite or s-video technologies as it digital and encompasses a host of handshakes and synchonization along with EDID display information signals that weren’t in analog. There isn’t even a video wire or an audio wire in a 19 wire HDMI cable as it is all digitized together. Many of the reported problems are about sending HDMI over long distances and not getting video or audio or having video but it has sparkles within the picture. The cause could be any one of a dozen plus problems but typically there are: 1. The HDMI cable is too long given the 1080p resolution being send and wire gauge. 2. The HDMI cable internal wires are too small. 3. The capacitance in the long HDMI cable impacts the resolution, like 1080p, being sent. 4. The HDMI source devices HDMI output doesn’t have enough voltage and current to drive a long HDMI cable. PC’s are notorius for that as ther video card designer thought his card would be used with only a 3 or 6 foot HDMI cable.
    [Show full text]
  • Military & Government Wire Specifications
    Military & Government Wire Specifications Callout Description JAN Join Army Navy specification J-C-90 Flexible cord and fixture wire J-C-96 Neoprene jacketed telephone wire J-C-580 Flexible cord and fixture wire J-C-741 Rubber and/or neoprene welding cable MIL-C-17 RG cables – polyethylene and Teflon TFE cores MIL-C-442B Two conductor parallel cable, rip cord MIL-C-915 Electrical cable for shipboard use MIL-C-1486 10 conductor WM-46/U MIL-C-2194 Navy shipboard cables with silicone rubber insulation MIL-C-3078 50 volt single conductor cable MIL-C-3162A Ignition cables for internal combustion engines MIL-C-3432B 300 and 600 volt rubber insulated power & control cable MIL-C-3458 Telephone cables MIL-C-3702 Ignition cables for internal combustion engines MIL-C-3849 Tinsel cord, light duty low voltage flexible cord for switchboards, microphones, telephones, etc. MIL-C-3883 Audio frequency electrical cord MIL-C-3884 Electrical conductor - short lay MIL-C-4839 KEL-F insulated cable, WF-15/U MIL-C-4866 RG-62/U Cable MIL-C-4921A (ASG) Single conductor 8 AWG, 5000 volt cable with butyl compound insulation and polychloroprene for airport lighting MIL-C-5136 Cable, power, electric, polychloroprene sheathed, buna compound insulated MIL-C-5756 Low temperature rubber portable cords MIL-C-6166 Cord, headset-microphone, CX1301/AR MIL-C-7078 600 volt aircraft wire using MIL-W-5086 components MIL-C-8721 Miniature coaxial cables with Teflon TFE cores MIL-C-8817 Aircraft ignition cables MIL-C-9360 RG 134/U cable MIL-C-10065 Special purpose electrical cables,
    [Show full text]