Lindner undertakes major worldwide projects in all areas of interior finishes, insulation technology, industrial services and building facades. From pre-planning through to project completion Lindner is your partner of choice. The Company’s extensive manufacturing capability enables quality to be strictly maintained whilst allowing maximum flexibility to meet individual project requirements. Environmental considerations are fundamental to all Lindner’s business principles. Through partnerships with clients Lindner turns concepts into reality.

Choosing Lindner you have:

Lindner Concepts: Lindner Products: Lindner Service: Tailored solutions specifically Quality materials and systems Comprehensive project geared to satisfy individual project to the very highest industry management services requirements standards

2 Plafotherm® Lindner offers heated and chilled ceilings for special applications Customisation is our Standard.

Our heated and chilled ceiling systems are developed For maximum functional reliability, we use ultra- to suit the requirements of national and international modern infra-red cameras to monitor smooth markets. At our in-house acoustic laboratory we flow-through of all types of pipework. After use highly sensitive measuring equipment to test commissioning we provide you with these thermal the acoustic properties of our various systems. imaging photographs showing the efficiency of your The heating and cooling capacity of our ceilings heated and chilled ceiling. It goes without saying is continuously measured and improved in our that Lindner offers long-term after-sales service for officially accredited climate chamber. The potential the entire system, whether maintenance or facility of innovative heating and cooling technologies can management. be best exploited by tailoring systems on a project- specific basis. Lindner can combine soundproofing, fireproofing, cooling and functionality by producing everything in-house. Our specialists co-ordinate the various technical requirements during the development phase, thus ensuring comprehensive engineering solutions.

Customer benefi ts at a glance - Development, production, installation and commissioning all from one source - Low-maintenance technology makes for ideal economic effi ciency. - Large selection of built-in components, such as lights, ventilation systems and speakers - Customised solutions available

3 Plafotherm® B 100 SD Fully insulated.

Post Cap heated/chilled ceiling, insulated against fl anking sound transmission

When you want to alter the floor layout as quickly and easily as possible use Plafotherm® B 100 SD which is insulated against flanking sound transmission. This system is often used in conjunction with demountable partition walls. With its outstanding longitudinal sound reduction properties of between 43 dB and 62 dB (depending on the ceiling design), this heated and chilled ceiling system is excellently suited to ensure soundproofing from room to room.

Standard requirement

Building material class A2-s1,d0 Light reflectance Lindner RAL 9010, plain tested to EN 13501-1 approx. 82 %

Sound absorption Heating capacity tested to DIN V 4706 and DIN EN 14037 tested to DIN EN 20354 (ISO 354) Cooling capacity ASTM C 423 tested to DIN 4715 and DIN EN 14240

Flanking sound transmission tested to Baustoffklasse A2-s1,d0 nach EN 13501-1 DIN EN ISO 140-9 m g it B n EN 13964* Quality standard eschichtu

Durability exposure class A tested to DIN EN 13964 Tables 7 and 8

4 System Description

Plafotherm® B 100 SD Heated/chilled ceiling, insulated against flanking sound transmission

Dn,c,w,P = 43 dB Ceiling element without , Lay-In, demountable.

Plafotherm® B 100 SD Heated/chilled ceiling, insulated against flanking sound transmission

Dn,c,w,P = 48 dB Ceiling element with mineral wool, Lay-In, demountable.

Plafotherm® B 100 SD Heated/chilled ceiling, insulated against flanking sound transmission

Dn,c,w,P = 62 dB Ceiling element with mineral wool and acoustic barrier, Lay-In, demountable.

Technical Data

Heating and cooling capacities Performance data Rated cooling capacity 200 tested to DIN 4715 (10 K) 92.4 W/m² cooling: 180 heating: Rated heating capacity 160 tested to DIN V 4706 (15 K) 131.3 W/m²

[W/m²] 140

ty i Recommended operating data c 120

a

p Flow temperature (cooling application) 15°-17° C a 100

c c Temperature spread 2 K - 4 K 80 ifi Flow temperature (heating application) 30°-35° C 60

Spec Temperature spread 4 K - 6 K 40 Recommended pressure drop 25-30 kPa 20 6,0 8,0 10,0 12,0 14,0 Excess and insufficient temperature [K] Additional facts Weight under service conditions approx. 25.5 kg/m² Determining excess or insufficient temperature Water volume approx. 1.0 l/m² Copper tubing 12 x 0.5 or 12 x 0.75 mm Tube distance 80-150 mm ΔTK = R – (VL + RL)/2

ΔTH = (VL + RL)/2 – R Connection T Δ K = insufficient temperature (cooling application) [K] Hoses of high-grade steel with easy-to-operate, ΔTH = excess temperature (heating application) [K]  = operative [°C] detachable fast-plug system, oxygen impermeable R tested to DIN 4726. VL = flow temperature [°C]

RL = return-flow temperature [°C] Sound absorption Depending on the degree of acoustic lining, perforated heated and chilled ceilings achieve sound

absorption up to αw = 0.50 (DIN EN ISO 11654) and/or to NRC = 0.60 (ASTM C 423), tested to DIN EN 20354 (ISO 354) and/ or ASTM C 423.

5 Plafotherm® F30 A cool ceiling for hot affairs.

Swing-down system with integrated heating and cooling functions

Plafotherm® F30-A/AB, with and without mineral wool, consists of a G-profile suspension system, enabling the ceiling panel to swing down and slide along the corridor, thus allowing inspection work in the ceiling void. Sturdy suspension hooks ensure that the panels will not fall out.

Where the building calls for -retardance, then the ceiling has to carry the fire resistance rating of F30 tested to DIN 4102-2 or EI30 tested to DIN EN 13501-2.

Classifications “A” or “AB” indicate which building materials may be used. With F30-A only non- Our heated and chilled ceiling systems Plafotherm® combustible building materials are permissible; F30-A/AB are in keeping with Building Material Class with F30-AB combustible building materials are also A2-s1,d0 tested to DIN EN 13501-1. This conforms to allowed, e.g. gaskets. ”non-combustible” building regulations.

Standard requirement

Building material class A2-s1,d0 Light reflectance Lindner RAL 9010, plain tested to EN 13501-1 approx. 82 %

Fire resistance F30-A/F30-AB Fire resistance F30-A/F30-AB tested to DIN 4102-2 tested to DIN 4102-2 from below from above

Flanking sound transmission tested to Heating capacity tested to DIN V 4706 and DIN EN 14037 DIN EN 20354 (ISO 354) Cooling capacity ASTM C 423 tested to DIN 4715 and DIN EN 14240

Durability Baustoffklasse A2-s1,d0 exposure class A nach EN 13501-1

m i g tested to DIN EN 13964 Tables 7 and 8 t B un EN 13964* Quality standard eschicht

6 System Description

Fireproof heated/chilled ceiling Plafotherm® F30-A/AB Type 6 Visible wall profile, ceiling elements with mineral wool, swing-down and sliding operation

Fireproof heated/chilled ceiling Plafotherm® F30-A/AB Type 7 Visible wall profile, ceiling elements without mineral wool, swing-down and sliding operation

Technical Data

Heating and cooling capacities Performance data Rated cooling capacity 200 tested to DIN 4715 (10 K) 92.4 W/m² cooling: 180 heating: Rated heating capacity 160 tested to DIN V 4706 (15 K) 131.3 W/m²

[W/m²] 140

ty i Recommended operating data c 120

a

p Flow temperature (cooling application) 15°-17° C a 100

c c Temperature spread 2 K - 4 K 80 ifi Flow temperature (heating application) 30°-35° C 60

Spec Temperature spread 4 K - 6 K 40 Recommended pressure drop 25-30 kPa 20 6,0 8,0 10,0 12,0 14,0 Excess and insufficient temperature [K] Additional facts Weight under service conditions approx. 26.5 kg/m² Determining excess or insufficient temperature Water volume approx. 1.0 l/m² Copper tubing 12 x 0.5 or 12 x 0.75 mm Tube distance 80-150 mm ΔTK = R – (VL + RL)/2

ΔTH = (VL + RL)/2 – R Connection T Δ K = insufficient temperature (cooling application) [K] Hoses plaited in high-grade steel with easy-to- ΔTH = excess temperature (heating application) [K]  = operative room temperature [°C] operate, detachable fast-plug system, oxygen R impermeable tested to DIN 4726. VL = flow temperature [°C]

RL = return-flow temperature [°C] Sound absorption Depending on the degree of acoustic lining, perfora- ted heated and chilled ceilings achieve sound absorp-

tion up to αw = 0.50 (DIN EN ISO 11654) and/or to NRC = 0.60 (ASTM C 423), tested to DIN EN 20354 (ISO 354) and/ or ASTM C 423.

7 LLP Lighting Systems Fireproofi ng element with integrated light fi tting.

Fireproof ceilings and good lighting no longer rule one another out. Type T38 LLP recessed light fitting has been included in the Lindner range especially for installation in fireproof ceilings. This slim light fitting allows the LMD F30 fireproof ceiling to act as a complete fireproof ceiling element with an overall height of 65 mm.

Type T38/20

Frameless recessed light fitting sits flush in an F30 or F90 metal ceiling element. The light fitting is installed in place of a ceiling tile. Glare-guard with parabolic mirror.

Technical Data Voltage: 220–240 volts / 50-60 Hz Protection class: 1 Protective system: IP 20 Dimensions: Width: 1-head, 70 mm 2-head, 143 mm Length: variable Types: All T16 (T5) Means of closure: Mirror grid diffuser Colour: To match the ceiling

Type T38/22

Frameless recessed light fitting integrated in an F30 or F90 metal ceiling element. The light fitting is installed in place of a ceiling tile. Light fitting cover made of transparent acrylic glass with prism structure – optimised for illumination of corridor areas.

Technical Data Voltage: 220–240 volts / 50-60 Hz Protection class: 1 Protective system: IP 20 Dimensions: Width: 78 mm, Length: variable Types: All T16 (T5) Means of closure: Frosted acrylic glass (PMMA) Colour: To match the ceiling

8 Ceiling element insulated against fl anking sound transmission with integrated light fi tting.

Recessed light fittings for ceilings needing to provide reduction of flanking sound transmission have to be chosen for their design and thermal performance, as well as their effect on the overall acoustic performance. As a result of system co-ordination and testing, solutions are available with a total construction height from 40 mm.

Type IS 20

Single light fitting integrated framelessly into metal ceiling. Concealment of sockets and elimination of the dark areas created by lamps give this light fitting a pleasing visual. Suitable for UGR (Unified Glare Rating) workplace as tested to EN 12464-1. Special V-shaped cross blades with closed ends made from highly reflective material ensure that our mirror grid diffusers are Technical Data energy efficient. Voltage: 220–240 volts / 50-60 Hz Protection class: 1 Protective system: IP 20 Dimensions: Variable width & length Types: All T16 (T5) lamps Means of closure: Mirror grid diffuser suitable for UGR (Unified Glare Rating) workplace Colour: RAL as desired

Type IS 22

Single light fitting integrated framelessly into metal ceiling. Excellent light quality with precise glare- guard function and even distribution of light through use of high-precision micro-prism cover made of PMMA.

Technical Data Voltage: Voltage 220–240 volts / 50-60 Hz Protection class: 1 Protective system: IP 20 Dimensions: Length: variable, width 180 mm: Types: All T16 (T5) lamps Means of closure: Frosted acrylic glass (PMMA) Colour: RAL as desired

9 Hydraulic Components For perfect connections.

For perfect heating and cooling connections, Lindner Advantages: provides a great number of hydraulic components - Tested system and accessory parts. - One-stop solutions - Ideal for heating/cooling systems - Maintained independently from other building trades

Multifunctional regulation unit The multifunctional regulation unit is ideal for heated and chilled ceiling systems. It consists of a multifunctional ball valve, a control valve with adjustable drive, system distributor, air-bleeding system and various connecting elements. This multifunctional ball valve makes it very easy to flush out and bleed the control zones independently of the main system. This means that the chilled ceiling can be maintained independently from other building trades.

Connection hoses and fittings High-grade steel hoses are in high-grade steel are oxygen impermeable, tested to DIN 4726, and are used as connection and distribution hoses. These hoses are perfectly suited to accept a large number of fittings. A system distributor with three outgoing lines completes the system.

Multilayer composite (MV) pipe system The MV pipe system is oxygen impermeable as per DIN 4726 and includes an MV system distributor with two and three outlets, MV clamped screw connection and special MV pressing transmission to which to fit the heating and cooling pipework.

Copper pipe system For main and distribution pipes, we offer high-quality, current-tested conduits made of copper as per EN 1057 and fittings as per EN 1254.

10 Look no longer for reasons not to. Profi t now from Lindner heated and chilled ceilings.

Unequalled process - In-house development department - Accredited test bench for heating and cooling systems - Metal ceilings and pipework from our own production - Assembly - Professional quality assurance system and environmental management

Comprehensive service - Installation - Pressure test - Commissioning - Functional testing/Thermal imaging - Maintenance

Specifications for tenders Guidelines Request the specifications for Installation guidelines: tenders by: All published information is in accordance with existing DIN and EN Tel. on +49 (0)8723/20-36 80 Standards and other relevant regulations. Lindner production conforms Fax on +49 (0)8723/20-26 90 to Quality Management Certificate DIN EN ISO 9001 and is also certified or by e-mail directly to us at by TÜV Management. The best visual result and performance of the heating.cooling@Lindner- ceiling will be achieved if installation is carried out in appropriate working Group.com or visit us on conditions and with the utmost care. the internet at www.Lindner- Group.com. Installation conditions: Installation of the substructure should only be started, if the preliminary services are at a stage where it is safe and efficient to commence. The ceiling should only be installed when the room is dry and sealed, all wet trades are finished and all external glazing and doors are installed. Differing parameters may be necessary depending on the individual project. During the installation of the ceiling, room temperatures of 10-25°C should be ensured.

Service: Technical information and documents (product sheets with guide specifications and installation instructions, test certificates, samples etc.) are available on request. We gladly offer comprehensive consulting services, for example specific building authority needs.

11 TU_HKT_BS/E/1.0

We can do it all for you.

Lindner Concepts: Lindner Products: Lindner Service:

- insulation engineering and - facades - general planning industrial service - ceiling systems - development and design - clearance of harmful substances - lights and lighting systems - delivery - clean rooms - partition systems - installation - airports and airlines - doors - maintenance - railways and - fl oor systems - studios and cinemas - heating and cooling - interior fi t-out and furnishings technologies - cruise liner and ship fi t-out - specialist dry lining - general contracting - Public-Private Partnership (PPP)

Lindner Bahnhofstrasse 29 94424 Arnstorf Germany Phone +49(0)8723/20-3680 Fax +49(0)8723/20-2690 heating.cooling@ Lindner-Group.com www.Lindner-Group.com

This document is the intellectual property of Lindner, Arnstorf (Germany). All the information contained in this brochure agrees with the information available at the time of its printing and only serves as advance information. Any possible colour deviations there might be from the original product are caused by printing-related reasons. Lindner is the sole and exclusive owner 12of the copyrights as well as the ancillary copyright. All use, and in particular any distribution, reprinting, exploitation or adaptation of this document shall only be allowed with express, written approval by Lindner.