Industrializing the Ethernet, Simplifying Industrial Communication

www.kyland.com

HQS - Kyland EMEA - Europe, Middle East, Africa Americas - North America & South America Asia Pacific KYLAND TECHNOLOGY CO., LTD. KYLAND TECHNOLOGY EMEA GmbH KYLAND CORPORATION AMERICAS KYLAND TECHNOLOGY ASIA PTE LTD Address: Building No.2,Shixing Avenue 30#, Address: Esslingerstrasse 7 (BOC),70771 Address: 14143 Denver West Parkway, Address: 229 Mountbatten Road #02-41, Shijingshan District, ,100041 Leinfelden-Echterdingen, Germany Suite100, Golden, CO 80401 USA Singapore 398007 Tel: +86-10-88798888 Tel : +49 (0) 711 997606-200 Tel: +1-303-447-6882 Tel: +65 3157 9226 Fax: +86-10-88796678 Fax : +49 (0) 711 997606-211 Email: [email protected] Email: [email protected] Email: [email protected] WEB: www.kyland.com

2016V1.1 RAIL AUTOMATION SOLUTIONS

Industrializing the Ethernet, Simplifying Industrial Communication

www.kyland.com Company Profile

Kyland Technology Ltd. is focusing on the research and implementation of industrial control networking total solutions.We are a leading Chinese company of industrial networking technology innovation and exploration.Our mission is to build the next generation industrial control ecosystem based on internet connectivity.

Kyland's primary R&D directions are: industrial Ethernet communications technologies, IP-based industrial fieldbus technologies, network-based field controller technologies, cloud-based industrial controlling server technologies, network-based controlling precise time/clock technologies, control message communication security technologies.

Kyalnd has been involved in the 3 international standards for industrial automation: IEC61158, IEC62439, IEEE C37.238, and the Chinese national standard GBT 30094. With the well-known test and certificates such as KEMA, CE/ FCC, UL508, ATEX, Class1 Div.2, DNV... etc., our products have been deployed worldwide, and have been proven to meet the requirements of rigorous environments like nuclear power plants, substations, oil & gas fields, railway & public transportation, ITS, marine, and military.

Customer Service and Quality Assurance are also the main focus of Kyland. We offer professional presales & post sales technical support and trainings for our clients. Moreover, our products are warranted for 5 years and free of replacement within 1 year. Only the material costs will be charged in the case of warranty expiry. Quality Assurance

EN50155 & EN50121 Shock & Vibration Electromagnetic Interference

Operating Temperature IRIS KEMA (-40 to 85đ )

www.kyland.com RAIL AUTOMATION SOLUTIONS CONTENT

High Speed Rail Signaling System Security Data Network Solutions ...... 1

Data Transmission Network for Mass Transit Signaling System ...... 3

IP Based TCMS Network for Onboard Systems ...... 5

PIS/PA Networking Solutions ...... 7

AFC Networking Solutions ...... 9

ISCS Network Aggregation Solutions ...... 11

Power SCADA Networking Solutions for Railway Traction System ...... 13

Industrializing the Ethernet, Simplifying Industrial Communication Introduction Recommended Products Rail Signaling System is the most important part of the Train Control SICOM6424SM System. The adopting technology has been developed from relay ȕ Supports maximum 8 Gigabit SFP ports and 16 system interlocking, computer based interlocking, to CTCS-2, CTCS-3. 100M ports The communication has been developed from traditional hard wire, ȕ Supports STP/RSTP, MSTP, DT-Ring, and IEC61439- serial communication to present industrial Ethernet. For the purpose 6(DRP) redundant ring protocol ȕ Supports layer 3 protocols such as RIP, static to establish a safe, reliable, standard unified new generation of security routing. Supports VRRP. data network, China Rail Corporation has released the Standards of ȕ Supports optical power detection. High Speed Rail Signaling System Security Data Network, Version 3.0. It ȕ Complies with IEC61850-3 and EN50121-4 defines all the functional requirements, networking requirements, the ȕ Operating temperature of -40 to 85°C selection of equipment, network structure, network management and etc. for the Security Data Network. SICOM3024 ȕ Supports maximum 4 Gigabit SFP ports and 16 System Requirements 100M ports ȕ Supports STP/RSTP, MSTP, DT-Ring, and IEC61439- ȕ Supports the isolation of different lines/bureaus through layer 6(DRP) redundant ring protocol 3 devices. ȕ Supports VLAN partition based on application ȕ Supports Gigabit/100M fiber ring network and excellent self- and management recovering performance in a huge network. ȕ Supports optical power detection. ȕ The Signaling System Security Data Network should ensure ȕ Complies with IEC61850-3 and EN50121-4 the safe and reliable communication of security data between ȕ Operating temperature of -40 to 85°C stations, relays, and signaling devices in control centers, such as RBC, TSRS. Kyview ȕ The latency of data transmission within network devices in each ȕ Friendly operating interface, several layers of single node is less than 50 microseconds. The recovery time of topology navigation structure, complete topology, the data communication within a single network is less than alarm, network, device information, which provide 50milliseconds. The recovery time of the data communication clear & wealth management information. between networks is less than 500 milliseconds. ȕ Clear navigation view provides global overview ȕ Supports network management system which enables the of each level of signaling system security network monitoring, recording, alarming and maintenance of the from administration, line, station, room, cabinet to network connection status, device working status and devices devices. operating parameters. ȕ Perfect management roles and authorities, log and backup functionalities enable the high security ȕ Resistant to the strong electromagnetic interference and and reliability of the system. voltage mutations. ȕ Supports southbound interface based on Corba which can be connected to the northbound of NMS. NMS+EMS, forming the complete integrated Why Kyland communication management system with high Taking part of driving Standards of High Speed Rail Signaling System management efficiency and lower management cost. Security Data Network, Version 3.0, Kyland released Ethernet switches and NMS fully meet the standards. Kyvision Pro

ȕ Supports layer 3 routing protocols such as RIP, static routing. ȕ Supports automatic topology discovery, topology import, export, dynamic refresh and manual ȕ Supports multiple ring redundancy protocol such as STP/RSTP, MSTP, drawing DT-Ring and IEC61439-6(DRP). The recovery time is less than 20ms. ȕ Supports network event replay ȕ Supports NTP, the accuracy reaches 10ms. ȕ Supports alarm dynamic display, alarm ȕ Kyview and Kyvision 3.0 Pro network management system confirmation, deleting and filtering providing network monitoring and management. ȕ Provide northbound interface based on Corba ȕ Supports optical power detection and data upload. which can be connected with the southbound ȕ Supports operating temperature range of -40 to 85°C interface of integrated managed system NMS. ȕ Complies with EN50121-4, high EMC level. ȕ Supports Syslog message receiving 01 High Speed Rail Signaling System 1 Security Data Network Solutions

www.kyland.com 02 Introduction Recommended Products Mass Transit system is one of the most important infrastructures SICOM3028GPT in the modern cities, while its Signaling system is the core of an ȕ Max. 28G ports or 4G + 24 Fast Ethernet ports efficient and effective train operation. Over the past decade, ȕ Flexible modular design with Ethernet/Fiber, CBTC (Communication-based Train Control) technology is widely ȕ Serial, GPS, HSR/PRP...etc. options implemented throughout the world for urban transportation, ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- 6(DRP) which requires a highly reliable DTS (Data Transmission System). ȕ Supports RIP, OSPF layer 3 routing protocols and VRRP System Requirements ȕ Compliant with IEC61850-3 and EN50121-4 ȕ Operating Temp.: -40 to 85°C ȕ Supports Gigabit Fiber Optic ring topology with fast self- healing functionality in a largescale network. SICOM3024P ȕ Supports network security functions. ȕ Max. 4G and 24 Fast Ethernet ports ȕ Centralized network management software to monitor, to ȕ Flexible Ethernet or Fiber ports combination configure and to maintain the network devices remotely. ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- ȕ Layer 3 capability to separate vital and non-vital networks. 6(DRP) ȕ Supports the access of serial devices, and enables the ȕ Supports Syslog, SNMP Trap communications between serial devices and devices ȕ Compliant with IEC61850-3 and EN50121-4 within the dual redundant ring network. ȕ Operating Temp.: -40 to 85°C

SICOM3000 Why Kyland ȕ 2 Gigabit SFP and 8 10/100Base-TX ports ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- ȕ SICOM3028GPT multi-functional platform supports 6(DRP) RIP, OSPF layer 3 routing protocols and rich options of ȕ Supports GMRP, DHCP, SNMP, QoS interface modules to ease the network expansion and ȕ Supports SNMPv3, HTTPS, SSH, 802.1X migration ȕ Compliant with IEC61850-3 and EN50121-4 ȕ Supports various Ring redundant protocols, like STP/RSTP, ȕ Operating Temp.: -40 to 85°C MSTP, DT-Ring and IEC62439-6(DRP) protocols ȕ Supports RS232/422/485 multiple serial protocols and bi- SICOM3005A direction data conversion between serial and Ethernet. ȕ 2 100Base-FX ports, 4 or 6 10/100Base-TX ports, 4 ȕ Serial device server supports static routing function which RS232/422/485 serial ports enables the interconnection between serial devices and ȕ Supports STP/RSTP, DT-Ring, IEC61439-6(DRP) devices within the dual redundant ring network. redundant ring protocols ȕ Supports white-list, mirroring and flow control for serial ȕ Supports static routing for serial ports ports, to realize the control and analysis with the serial ȕ Supports white-list, port-mirroring, flow control with data. the serial ports ȕ Operating Temp.: -40 to 85°C ȕ Supports wide operating temperature ranges from -40 to 85°C ȕ Compliant with EN50121-4, with high EMC resistance KOM600G ȕ Unified NMS, Kyvision3.0 for network monitoring and ȕ 1 10/100/1000Base-TX port, 1 Gigabit SFP port management ȕ Redundant power inputs with less than 4.5W power ȕ Supports VLAN, QoS, IGMP for broadcast storm isolation consumption (full loaded) and bandwidth utilization ȕ Supports LFP (Link Fault Pass-Through) ȕ Operating Temp.: -40 to 85°C

03 Data Transmission Network for Mass 2 Transit Signaling System

LTE/Wifi

SICOM3028GPT SICOM3024P

KOM600G

SICOM3005A

Network A SICOM3024P SICOM3000 Network B

www.kyland.com 04 Introduction TCMS (Train Control and Management System) is the core of train operation, which carries several critical services, such as traction power, auxiliary power, speed, location, braking, door control, HVAC, train status monitoring and diagnosis. With the popularity and maturity of Ethernet technologies, an IP based TCMS and related specifications such as ETB (Ethernet Train Backbone) and ECN (Ethernet Consist Network) are defined in IEC61375.

System Requirements ȕ Train bus topology automatic generation during train formation. ȕ ETB Automatic IP re-arrangement for Ethernet Switches in accordance with train marshalling (TTDP). ȕ The translation of train level IP address and consist level IP address. ȕ Routing protocol enables communication between different coaches/consists. ȕ Network redundancy avoiding communication interruption due to single point failure. ȕ Security function to prevent unauthorized user access and operation ȕ PoE output for low and medium power electronics, such as PIS ȕ Uninterrupted Ethernet backbone communications while single coach power failure ȕ Extraordinary industrial design against shock, vibration, EMC, unstable power supply for onboard environment

HAVC PIS DCU

DCU

TS TD MPU TCU BCU ACU

Why Kyland Aquam series is specially designed for onboard ETB & ECN applications. ETBN complies with IEC61375-2-5 and IEC61375- 2-3. ECN complies with IEC61375-3-4.

ȕ Supports TTDP which enables the automatic generation and maintenance with the train communication network topology. ȕ IP address allocation according to the rules defined by IEC61375. ȕ Supports DHCP server, DHCP client, DHCP Opt. 82 ȕ Supports R-NAT (ETBN), realizing the translation of train level IP address and coach level IP address. ȕ Supports routing. The routing table is automatically generated according to the train network topology. ȕ Supports VRRP and realizes the redundancy of ETBN within a consist.

05 IP Based TCMS Network for Onboard 3 Systems

Recommended Products Aquam8512AA Aquam8012AA ȕ Layer 3 ETB Industrial Ethernet Switch with ȕ Layer 2 ECN Industrial Ethernet Switch IP65 rating ȕ 4G+8 or 3G+9 10/100M ports with max. ȕ 4G+8 or 3G+9 10/100M ports with max. 9PoE 9PoE ȕ Compliant with IEC61375-2-5, IEC61375-2-3 ȕ Supports relay bypass ȕ Supports R-NAT, TTDP, DHCP ȕ Supports 24-110VDC wide range power ȕ Supports relay bypass input with max. 61.6W PoE output ȕ Supports STP/RSTP, MSTP, DT-Ring and ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) IEC62439-6(DRP) ȕ Compliant with EN50155, EN50121 & EN45545 ȕ Compliant with EN50155, EN50121 & EN45545 Aquam8512A

ETB Network ECN Network To End Device Aquam8012A

ȕ Supports IEC61439-6(DRP) ring redundancy protocol which forms the redundant communication network within ECNs. The recovery time is less than 20ms. ȕ Supports security features such as IEEE802.1X, SSH/SSL, TACACS+, RADIUS, ACL etc. ȕ Max. 9 PoE ports with IEEE802.3af & IEEE802.3at compliance ȕ Supports relay bypass function on up to 2 Gigabit uplinks to avoid power failure ȕ Structure design dedicated to onboard application with M12 connectors which support excellent anti-vibration performance. ȕ Compliant with EN50155 with M12 connectors

www.kyland.com 06 Introduction Recommended Products Accurate & reliable operation of Passenger Information and Public Address Systems are the primary factors for passenger Aquam8512A/Aquam8512A-1U ȕ Layer 3 ETB Industrial Ethernet Switch satisfaction. PIS/PA are generally composed of display board, ȕ 4G+8 or 3G+9 10/100M ports with max. 9PoE broadcasting audio system, and a reliable communications ȕ Compliant with IEC61375-2-5/IEC61375-2-3 ȕ Supports R-NAT, TTDP, DHCP network, not only the onboard network but also the ground ȕ Supports relay bypass network towards the operation control center. ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- 6(DRP) ȕ IP65 protection class ȕ Supports 24-110VDC wide range power input and System Requirements max. 61.6W PoE output ȕ Redundant network technology to ensure failover recovery ȕ Wall mount or rack mountable installation ȕ Certified with EN50155, EN50121 & EN45545 ȕ Extraordinary industrial design against shock, vibration, EMC, unstable power supply for onboard environment Aquam8012A/Aquam8012A-1U ȕ Routing and NAT to ease onboard inbound/outbound communications ȕ Layer 2 ECN Industrial Ethernet Switch ȕ 4G+8 or 3G+9 10/100M ports with max. 9PoE ȕ Automatic IP assignment for end devices ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- ȕ Network multicasting function 6(DRP) ȕ PoE output for low and medium power electronics, such as ȕ IP65 protection class display board ȕ Supports 24-110VDC wide range power input and ȕ Long distance Ethernet extension to reach out trackside max. 61.6W PoE output cabinets ȕ Wall mount or rack mountable installation ȕ Compact installation for rail onboard applications ȕ Certified withEN50155, EN50121 & EN45545 ȕ High protection class preventing the harm of metal powder SICOM3028GPT/SICOM3024P ȕ Max 28 x 1G or 4 x 1G and 24 Fast Ethernet ports Why Kyland ȕ Flexible modular design for Ethernet or Fiber ȕ Supports versatile Ring technologies, e.g. STP/RSTP, MSTP, DT- ports Ring and IEC62439-6(DRP) ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- 6(DRP) ȕ Compliant with EN50155 with M12 connectors for onboard ȕ Supports Syslog, SNMP Trap Ethernet switches ȕ Compliant with IEC61850-3 and EN50121-4 ȕ Supports DHCP, TTDP, R-NAT and static, RIP, OSPF routing ȕ IP 40 protection class features ȕ Operating Temp.: -40 to 85°C ȕ Supports IGMP Snooping KOM600G/KOM300A ȕ Compliant with IEEE802.3af IEEE802.3at PoE ȕ 1Gbps/100Mbps Fiber converter ȕ Wide range power inputs for onboard devices ȕ High EMC resistance with IP40 rating ȕ Supports standard 12,24/48V and high voltage ȕ IP40 to IP65 protection class 220VAC/DC power input ȕ Compact DIN-Rail type industrial Ethernet-to-Fiber converter ȕ IP40 protection class ȕ Certified with EN50121/EN50155/EN45545 ȕ Operating temp.: -40 to 85°C ȕ Compliant with Class 1 Div. 2

07 4 PIS/PA Networking Solutions

SICOM3028GPT / SICOM3024P

WiFi

Passenger Public Information Address System Wifi

Public WiFi Address

Camera KOM600G / KOM300A WiFi

WiFi Fiber Camera 喍for passengers喎 Ethernet

Camera

Aquam8512A / Aquam8512A-1U Aquam8012A / Aquam8012A-1U

www.kyland.com 08 Introduction Recommended Products In order to retain smooth and effective ticketing SICOM6448G operation for railways, automated fare collection ȕ Layer 3 core switch (AFC) system is introduced to modern transportation. ȕ Max. 48G + 4 10G ports It generally consists of ticket vending machine, fare gate ȕ Supports static routing, RIP, OSPF, VRRP ȕ Supports IEEE802.1X, ACL and backend accouting system. Though it's less critical ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439- for train operation, it's most critical for the operator 6(DRP) working capital. ȕ Operating temperature -20 to 65°C

SICOM3028GPT System Requirements ȕ Layer 3 core switch ȕ High availability with low failure rate ȕ Max. 24+4G ports

ȕ Industrial design to resist shock & vibration, and also ȕ Supports static routing, RIP, OSPF, VRRP extreme operating ambience ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) ȕ Supports IEEE802.1X, ACL ȕ Network redundancy to mitigate link or node failure ȕ Supports QoS, VLAN, SNMP effects ȕ Operating temp.: -40~85đ ȕ High bandwidth and routing platform for inter-station connection SICOM3016 ȕ Support centralized management ȕ Max. 4FX + 16TX ports

ȕ Support routing protocols to exchange data with external ȕ Supports STP/RSTP, MSTP, DT-Ring network ȕ Supports QoS, VLAN, SNMP ȕ Compliant with IEC61850-3 & IEEE1613 ȕ Operating temperature -40 to 85°C Why Kyland ȕ Fanless design, dual power supplies with long MTBF (>200,000hrs) SICOM3024 ȕ Supports -40 - 85°C wide operating temperature and high EMC ȕ Max. 4G+24 10/100Base-TX ports resistance ȕ Supports STP/RSTP, MSTP, DT-Ring redundant ring ȕ Supports various redundant Ring redundant protocols, like protocols ȕ Supports Syslog, SNMP Trap STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) ȕ Compliant with IEC61850-3 & IEEE1613 ȕ Supports Layer 3 routing protocols such as RIP and OSPF ȕ Operating temperature -40 to 85°C ȕ Supports VRRP for layer 3 redundancy

09 5 AFC Networking Solutions

SICOM3028GPT

SICOM6448G SICOM3024

Clearing Center

SICOM3016

Fiber Ethernet

www.kyland.com 10 Introduction Recommended Products Integrated Supervisory and Control System, ISCS plays a crucial role to make a centralized and comprehensive SICOM6448G operation for city . All the major systems, from vital ȕ Layer 3 core switch to non-vital, from the field to center, such as AFC, PIS/ ȕ Max. 48G + 4 10G ports ȕ Supports static routing, RIP, OSPF, VRRP PA, Clock, CCTV, BAS, FAS, PSCADA, ATS, TMS... etc. can be ȕ Supports IEEE802.1X, ACL integrated into one single supervision and control room. ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) ȕ Operating temperature -20 to 65°C System Requirements ȕ High bandwidth with 10G capability to support multiple SICOM3028GPT services into one big backbone network ȕ Layer 3 multi-function switch ȕ Max. 28G ports ȕ Flexible, fast recovery and dual ring network with failure-free ȕ Support static routing, RIP, OSPF, VRRP power supply ȕ Supports STP/RSTP, MSTP, DT-Ring and ȕ Routing and network protection to work with different network IEC62439-6(DRP) segments ȕ Supports QoS, VLAN, SNMP

ȕ User friendly network management SICOM3016 ȕ Max. 4FX + 16TX ports Why Kyland ȕ Supports STP/RSTP, MSTP, DT-Ring ȕ Supports QoS, VLAN, SNMP ȕ Rich industrial Ethernet Switch portfolio ranges from 5 10/100Mbps to max. 48G/96G+4 10G ȕ Comprehensive network redundant functions, e.g. RSTP, DT-Ring, SICOM3005A DRP (IEC62439-6), HSR/PRP(IEC62439-3) with sub-second recovery ȕ 2FX+4TX or 6TX Fast Ethernre ports time and multiple ring connectivity ȕ 4 RS232/422/485 Serial ports ȕ Supports STP/RSTP, MSTP, DT-Ring and ȕ Redundant & hot swappable power module IEC62439-6(DRP) ȕ Backbone Layer 3 switch supports RIP, OSPF, IEEE802.1X, ACL ȕ High EMC resistance ȕ Own developed NMS with intuitive GUI , Kyvision3.0 for network monitoring and management Kyvision3.0 ȕ Supports max. 1000 nodes ȕ Supports LLDP and user-friendly GUI ȕ Supports historic operation journal and alarm log ȕ Supports real-time alarm via email or SMS

11 ISCS Network Aggregation 6 Solutions

SICOM3028GPT SICOM6448G Kyvision3.0

Kyvision3.0

NMS

Log Server CCTV TCS Time Server PA PIS AFC

PSCADA FAS BAS

Termiral Termiral

SICOM3005A SICOM3028GPT SICOM3016

www.kyland.com 12 Introduction Recommended Products Traction power supply systems are the basic SICOM3024P infrastructure for train operation. Transformers, ȕ Max. 4G and 24 Fast Ethernet ports switch-gears, low-voltage power distribution and ȕ Flexible modular design for Ethernet or Fiber ports control/protection devices are installed along the ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) ȕ Supports Syslog, SNMP Trap tracks, while the Power SCADA system ensures the ȕ Compliant with IEC61850-3 service availability through its real time control and ȕ Operating temp.: -40~85đ supervision. SICOM3009A System Requirements ȕ Max. 3FX + 6TX, or 8TX ȕ Flexible modular design for Ethernet or Fiber ports ȕ Industrial design to sustain under harsh environment, severe EMC condition in substation ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) ȕ Compliant with IEC61850-3 ȕ Network redundancy to mitigate link or node failure ȕ Operating temp.: -40~85đ effects ȕ Network management capabilities to ease maintenance and operation SICOM3005A ȕ Versatile mounting types and power input options ȕ 2FX+4TX or 6TX Fast Ethernre ports ȕ 4 RS232/422/485 Serial ports ȕ Supports STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) Why Kyland ȕ High EMC resistance ȕ Compliant with IEC61850-3 ȕ Operating temp.: -40~85đ ȕ Supports various redundant Ring redundant protocols, like STP/RSTP, MSTP, DT-Ring and IEC62439-6(DRP) ȕ Unified NMS, Kyvision3.0 for network monitoring and Kyvision3.0 management ȕ Supports max. 1000 nodes ȕ Supports LLDP and user-friendly GUI ȕ Standard 19" rack-mount type and also compact DIN-Rail ȕ Supports historic operation journal and alarm log type Ethernet switches with high voltage power input ȕ Supports real-time alarm via email or SMS

13 Power SCADA Networking Solutions 7 for Railway Traction System

Kyvision3.0 SICOM3009A SICOM3024P

SICOM3005A

Substation IED

IED

IED

Substation RTU

RTU

RTU

Substation

www.kyland.com 14 RAIL AUTOMATION SOLUTIONS

Mass Transit

PIS/PA, CCTV, Access Control Systems

Location Project

China, PIS display renovation network for stations

China,China, P PIS/PAIS/PA network for

China, Shenzhen PIS/PA network for Shenzhen metro

China,China, WuWuhanhan P PIS/PAIS/PA network forfor

China, PIS/PA network for line 2

China,China, ShanShanghaighai P PIS/PAIS/PA network for ShanShanghaighai metro line 2

China, Shanghai PIS/PA network for Shanghai metro line 3

China,China, SShanghaihanghai P PIS/PAIS/PA network forfor ShanghaiShanghai metro line 4

China, Shanghai PIS/PA network for Shanghai metro

China,China, ShanShanghaighai P PIS/PAIS/PA network for ShanShanghaighai metro

China, Shanghai PIS/PA network for Shanghai metro line 8

China,China, SShanghaihanghai P PIS/PAIS/PA network forfor ShanghaiShanghai metro

China, Guangzhou PIS/PA network for Guang-Fo line

China,China, ChonChongqinggqing P PIS/PAIS/PA network for ChonChongqinggqing metro

China, CCTV network for line 2

China,China, TianTianjinjin C CCTVCTV network forfor TianjinTianjin metro line 3

China, Shenzhen CCTV network for Shenzhen metro line 2

China,China, Shenzhen C CCTVCTV netwnetworkork forfor Shenzhen metrometro line 5

China, Beijing ACS for Beijing metro Fangshan line

China,China, SShenzhenhenzhen A ACSCS fforor Shenzhen metro line 2

15 Mass Transit

AFC/ACS/CBTC/TCS

Location ProjectProject

China, Shenzhen AFC network for Shenzhen metro line 2

China, AFC network for Shenyang metro line 2

China, Chengdu AFC network for Chengdu metro line 1

China, Beijing AFC network for Beijing metro

India, Chennai AFC network for

China, Chengdu CBTC trackside network for Chengdu metro line 1

China, Changchun TCS network for Changchun Railway Passenger Trains

ISCS/PSCADA/FAS/BAS

Location ProjectProject

China, Shenzhen ISCS network for Shenzhen Metro line 1 extension

China,China, SShenzhenhenzhen ISCS network forfor Shenzhen Metro line 2

China, Beijing Power SCADA network for Beijing metro line 4

China, BeijingBeijing Power SCADA network for BeijingBeijing metro line 5

China, Beijing Power SCADA network for Beijing metro line 15

China,China, Beijing Power SCADA network forfor Beijing metro airport lineline

China, Wuhan Power SCADA network for Wuhan line 1 phase 2

China,China, Shenzhen Power SCADA network for Shenzhen metro line 2

China, Shenzhen Power SCADA network for Shenzhen metro line 3

China,China, SShenzhenhenzhen Power SCADA network forfor Shenzhen metro line 5

China, Shanghai Power SCADA network for Shanghai metro

China,China, Haerbin Power SCADA network for Haerbin metro line 1

China, Nanjing Power SCADA network for line 2

China,China, SShenzhenhenzhen BAS network forfor Shenzhen metro line 2

China, Shenzhen BAS network for Shenzhen metro line 3

China, GuanGuangzhougzhou FAS network for GuanGuangzhougzhou metro line 5

India, Hyderabad Power SCADA network for line 1

www.kyland.com 16 RAIL AUTOMATION SOLUTIONS

Mainline/High-speed Rail

Trackside Network Systems

LocationLocation ProjectProject

China Trackside network for Nanchang-Jiujiang inter-city railway

ChinaChina Trackside network forfor Changchun-Jilin inter-city railwarailwayy

China Trackside network for Dazhou-Chengdu High-speed railway

China Trackside network for Taiyuan-ZhongweiTaiyuan-Zhongwei High-speed railwayrailway

China Trackside network for Longyan-Xiamen High-speed railway

ChinaChina Trackside network forfor Suining-Chongqing High-speed railway 1SStt LLineine

China Trackside network for Suining-Chongqing High-speed railway 2nd Line

China Trackside network for Zhengzhou-Xi' an High-speed railwarailwayy

China Trackside network for Baotou-Lanzhou High-speed railway

ChinaChina Trackside network forfor Xiamen-Shenzhen High-speed railway

China Trackside network for Shenzhen-Xiamen High-speed railway

China Trackside network for Chongqing-Lichuan High-speed railwayrailway

China Trackside network for Wuhan-Huanggang High-speed railway

ChinaChina Trackside network forfor Maoming-Zhanjiang High-speed railwayrailway

China Trackside network for Liuzhou-Nanning High-speed railway

ChinaChina Trackside network for XiangGui High-speed railwarailwayy

China Trackside network for Nanjing-Anqing High-speed railway

ChinaChina Trackside network forfor Da-Cheng High-speed railway

China Trackside network for Cexian, Neimeng High-speed railway

China Trackside network for Chengdu east line High-speed railwayrailway

China Trackside network for Wuhan-Xianyang line High-speed railway

ChinaChina Trackside network forfor Beijing-Tianjin High-speed railway

China Trackside network for Shandong High-speed railway

17 Mainline/High-speed Rail

PSCADA/BAS/ISCS/Interlocking Systems

LocationLocation ProjectProject

China Power SCADA network for Lanzhou-Xinjiang railway

ChinaChina Power SCADA network forfor Hefei-NanjingHefei-Nanjing railwayrailway

China Power SCADA network for Wuhan-Guangzhou high speed railway

ChinaChina Power SCADA network for Shanghai-Hangzhou railwarailwayy

China Power SCADA network for Chengdu-Kunming railway

ChinaChina Power SCADA network forfor Zhengzhou-Xi' an high speed railwayrailway

China Power SCADA network for Guangzhou-Foshan railway

ChinaChina Power SCADA network for Wenzhou-Fuzhou railwarailwayy

China Power SCADA network for Beijing-Jiulong railway

ChinaChina Power SCADA network forfor Beijing-Tianjin railwayrailway

China BAS network for Qinghai-Tibet railway

ChinaChina BAS network for Wuchang railwayrailway

China BAS network for Nanjing South railway station

ChinaChina Interlocking network forfor Hong-Nao-San railwayrailway

Russia Interlocking network for Russian railway

ChinaChina ISCS network for Cheng-Yu railwayrailway

China ISCS network for Lan-Xin railway

ChinaChina ISCS network forfor Lan-Xin railwayrailway line 2

China ISCS network for Chongqing inter-city railway

ChinaChina ISCS network for Wu-Guang railwarailwayy

China ISCS network for Shenyang railway

ChinaChina ISCS network forfor Guangzhou-Shenzhen-Hongkong railwayrailway

China ISCS network for Wuhan-Yichang railway

www.kyland.com 18