Halogen Lamps

Total Page:16

File Type:pdf, Size:1020Kb

Halogen Lamps ® HALOGEN LAMPS CONTENTS 118 How to Read a Table 119 PAR Lamps 121 A19 Lamps 121 Aluminum Reflector Lamps 121 Double Envelope Lamps 122 MR8, MR11, MR16 Lamps 126 JC Type Lamps 127 J Type Double Ended Lamps 128 JD Type Single Ended Lamps 130 Bulb, Base and Filament Identification 131 Symbols, Footnotes and Abbreviations HOW TO READ A HALOGEN LAMP TABLE PACKAGE QUANTITY Indicates minimum sell quantity BULB and smallest shipping carton. Designations indicate shape and size. Illustrations can be found on page 130 and at the top of each page. DESIGN FILAMENT Filament types are illustrated on BASE PRODUCT CODE page 130. Indicates base type. Abbreviated product description Full base descriptions can also be used for ordering. VOLTS and illustrations can be A key to abbreviations can be Indicate the found on page 130. found on page 132. MOL product’s Indicates design voltage maximum of operation. overall length in inches. Product Product Pkg. Avg. Design Beam Bulb Base Footnotes Description Volts Lumens CBCP MOL Number Code Qty. Life Filament Spread & JC Type 5 WATT T3 G4 107006 3 JC5 Clear 10/1000 12 60 2800 3000 C-8 1.18” - 10 WATT T3 BA15s 147008 3 JC10/BA15S Clear 10/1000 12 120 2800 3000 C-8 1.50” - 107944 2,3 JC10/BA15S/HX Clear HaloXen® 10/1000 12 120 2850 10000 C-8 1.50” - G4 107008 3 JC10 Clear 10/1000 12 120 2800 3000 C-8 1.18” - 107710 2,3 JC10/HX Clear HaloXen® 10/1000 12 120 2850 10000 C-8 1.18” - 90002 3 JC10/X Clear Xenon 10/500 12 120 2700 20000 C-8 1.18” - DESCRIPTION WATTS FOOTNOTES & AVERAGE Bulb finish and other Indicates the SYMBOLS LIFE important information. power consumed Related footnotes can Average rated life by the lamp during be found on page 131. expressed in hours. operation. LUMENS PRODUCT Represents NUMBER the average Use this number when light output. placing an order. BEAM SPREAD Indicates the CBCP beam angle or The luminous beam spread intensity at the center of a bulb, of the beam of a measured in reflector lamp. degrees. TOC HALOGEN LAMPS PAR30 PAR38 PAR30L PAR36 PAR20 PAR16 Product Product Pkg. Avg. Design Beam Bulb Base Footnotes Description Volts Lumens CBCP MOL Number Code Qty. Life Filament Spread , , & PAR Lamps 20 WATT PAR36 MP- 70304 X $ 1,7 HP36WFL20/24V Wide Flood 1/12 24 240 480 5000 CC-6 2.75” 32° Term. 107788 $ 1,2,7 HP36NSP20/HX Narrow Spot HaloXen® 1/12 12 260 1900 5000 C-6 2.75” 12° Very Narrow Spot 107790 $ 1,2,7 HP36VNSP20/HX 1/12 12 260 9000 5000 C-6 2.75” 5° HaloXen® 107792 $ 1,2,7 HP36WFL20/HX Wide Flood HaloXen® 1/12 12 260 530 5000 C-6 2.75” 32° 35 WATT PAR20 Med. 107610 N $ 1,7,8 HP20NFL35 Narrow Flood 15 130 450 700 3000 CC-8 3.07” 30° PAR36 MP- 107794 $ 1,2,7 HP36NSP35/HX Narrow Spot HaloXen® 1/12 12 540 3500 5000 C-6 2.75” 12° Term. Very Narrow Spot 107796 $ 1,2,7 ® 1/12 12 540 17000 5000 C-6 2.75” 5° HP36VNSP35/HX HaloXen 107798 $ 1,2,7 HP36WFL35/HX Wide Flood HaloXen® 1/12 12 540 1000 5000 C-6 2.75” 32° 70306 $ 1,2,7 HP36WFL35/24V Wide Flood 1/12 24 500 960 5000 CC-6 2.75” 32° 39 WATT PAR20 Med. 70343 $ 1,2,7 HP20NFL39/HX Narrow Flood HaloXen® 1/15 120 530 900 2000 CC-8 3.23" 30° 70354 $ 1,2,7 HP20NFL39/HX/130 Narrow Flood HaloXen® 1/15 130 530 900 2000 CC-8 3.23” 30° PAR30 Med. 70347 $ 1,2,7 HP30FL39/HX Flood HaloXen® 1/15 120 530 1100 2000 CC-8 3.62" 30° 70353 $ 1,2,7 HP30FL39/HX/130 Flood HaloXen® 1/15 130 530 1100 2000 CC-8 3.62” 30° PAR30L Med. 70344 $ 1,2,7 HP30FL39L/HX Flood HaloXen® 1/15 120 530 1000 2000 CC-8 4.75" 36° 70204 $ 1,2,7 HP30WFL39L/HX Wide Flood HaloXen® 1/15 120 530 650 2000 CC-8 4.75" 50° 70203 $ 1,2,7 HP30SP39L/HX Spot HaloXen® 1/15 120 530 4000 2000 CC-8 4.75" 15° 70356 $ 1,2,7 HP30FL39L/HX/130 Flood HaloXen® 1/15 130 530 4000 2000 CC-8 4.75” 36° PAR38 Med. 70340 $ 1,2,7 HP38FL39/HX Flood HaloXen® 1/15 120 530 1000 2000 CC-8 5.31” 30° 70404 $ 1,2,7 HP38SP39/HX Spot HaloXen® 1/15 120 530 5000 2000 CC-8 5.31" 10° 70355 $ 1,2,7 HP38FL39/HX/130 Flood HaloXen® 1/15 130 530 1100 2000 CC-8 5.31” 30° 45 WATT PAR16 Med. 107502 N $ 1,7,8 HP16NFL45 Narrow Flood 15 130 450 850 3000 CC-2V 3.07” 30° 50 WATT PAR36 MP- 107782 1,2,7 HP36NSP50/HX Narrow Spot HaloXen® 1/12 12 910 5000 5000 C-6 2.75” 12° Term. Very Narrow Spot 107784 1,2,7 ® 1/12 12 910 25000 5000 C-6 2.75” 5° HP36VNSP50/HX HaloXen 107786 1,2,7 HP36WFL50/HX Wide Flood HaloXen® 1/12 12 910 1500 5000 C-6 2.75” 32° PAR38 Med. 70350 E 1,2,7 HP38FL50/S/HX Silver PAR Flood HaloXen® 1/15 120 920 1300 1500 CC-8 5.31” 30° 53 WATT PAR30 Med. 70310 E $ 1,2,7 HP30FL53/XIR Flood XIR® 1/15 120 1050 2500 3500 CC-8 3.62” 30° PAR30L Med. 70311 E $ 1,2,7 HP30FL53L/XIR Flood XIR® 1/15 120 930 2500 3500 CC-8 4.75” 30° PAR38 Med. 70312 E $ 1,2,7 HP38FL53/XIR Flood XIR® 1/15 120 960 4100 3500 CC-8 5.31” 25° E Means this lamp meets Federal Minimum Efficiency standards. Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133. Halco Lighting Technologies | 800.677.3334 | halcolighting.com TOC 119 HALOGEN LAMPS BR30 BR38 PAR30 PAR56 BR40 PAR16 PAR30L PAR38 PAR64 Product Product Pkg. Avg. Design Beam Bulb Base Footnotes Description Volts Lumens CBCP MOL Number Code Qty. Life Filament Spread , , & PAR Lamps continued 60 WATT PAR16 Med. 107616 N $1,7,8 HP16NFL60 Narrow Flood 15 130 550 1500 3000 CC-8 3.07” 30° 107850 N $1,7,8 HP16NFL60/120 Narrow Flood 15 120 550 1500 3000 CC-8 3.07” 30° 107504 N $1,7,8 HP16NSP60 Narrow Spot 15 130 550 4000 3000 CC-8 3.07” 10° PAR30 Med. 70345 E $ 1,2,7 HP30FL60/S/HX Silver PAR Flood HaloXen® 1/15 120 1090 2300 1500 CC-8 3.62” 30° PAR30L Med. 70342 E $ 1,2,7 HP30FL60L/S/HX Silver PAR Flood HaloXen® 1/15 120 1090 1900 1500 CC-8 4.75” 36° Silver PAR Wide 70349 E $ 1,2,7 HP30WFL60L/S/HX ® 1/15 120 1090 1200 1500 CC-8 4.75” 50° Flood HaloXen 70348 E $ 1,2,7 HP30SP60L/S/HX Silver PAR Spot HaloXen® 1/15 120 1090 5800 1500 CC-8 4.75” 15° PAR38 Med. 70341 E $ 1,2,7 HP38FL60/S/HX Silver PAR Flood HaloXen® 1/15 120 1090 2000 1500 CC-8 5.31” 30° 65 WATT BR30 Med. 75009 1,7 BR30FL65/H Flood 24 120 750 - 2500 CC-8 5.37” - BR40 Med. 75010 1,7 BR40FL65/H Flood 24 120 750 - 2500 CC-8 6.56” - 70 WATT PAR38 Med. 70346 E $ 1,2,7 HP38FL70/S/HX Silver PAR Flood HaloXen® 1/15 120 1350 2800 1500 CC-8 5.31” 30° 70352 E $ 1,2,7 HP38SP70/S/HX Silver PAR Spot HaloXen® 1/15 120 1350 7200 1500 CC-8 5.31” 10° 80 WATT PAR38 Med. 70351 E $ 1,2,7 HP38FL80/S/HX Silver PAR Flood HaloXen® 1/15 120 1580 3000 1500 CC-8 5.31” 30° 250 WATT PAR38 Med. 15558 N 1,5,7 Q250PAR/FL Flood Major 1/6 120 3600 9000 4500 CC-8 5.32” 30° 15526 N 1,5,7 Q250PAR/SP Spot Major 1/6 120 3600 40000 4500 CC-8 5.32” 10° 500 WATT PAR56 End 65044 1,5,6,7 PAR56MFL500Q Medium Flood 1/12 120 8000 43000 3000 CC-6 5.00” 30x11 Prg. 65043 1,5,6,7 PAR56NSP500Q Narrow Spot 1/12 120 8000 73500 3000 CC-6 5.00” 15x8 65045 1,5,6,7 PAR56WFL500Q Wide Flood 1/12 120 8000 19000 3000 CC-6 5.00” 45x20 E Means this lamp meets Federal Minimum Efficiency standards. Halogen lamp symbols, footnotes and abbreviations are located on pages 131-133. 120 TOC Halco Lighting Technologies | 800.677.3334 | halcolighting.com HALOGEN LAMPS A19 AR111 BT15 Product Product Pkg. Avg. Design Beam Bulb Base Footnotes Description Volts Lumens CBCP MOL Number Code Qty. Life Filament Spread A19 Lamps 29 WATT A19 Med. 76005 E $ A19CL29/H Clear 12/120 120 430 - 1000 CC-8 4.25” - 76001 E $ A19SW29/H Soft White 12/120 120 430 - 1000 CC-8 4.25” - 43 WATT A19 Med. 76006 E $ A19CL43/H Clear 12/120 120 750 - 1000 CC-8 4.25” - 76004 E $ A19SW43/H Soft White 12/120 120 750 - 1000 CC-8 4.25” - 53 WATT A19 Med. 76007 E $ A19CL53/H Clear 12/120 120 1050 - 1000 CC-8 4.25” - 76002 E $ A19SW53/H Soft White 12/120 120 1050 - 1000 CC-8 4.25” - 72 WATT A19 Med.
Recommended publications
  • 16 CFR Ch. I (1–1–20 Edition) § 305.22
    Federal Trade Commission Pt. 305 PART 305—ENERGY AND WATER 305.27 Paper catalogs and websites. USE LABELING FOR CONSUMER ADDITIONAL REQUIREMENTS PRODUCTS UNDER THE ENERGY 305.28 Test data records. POLICY AND CONSERVATION 305.29 Required testing by designated lab- ACT (‘‘ENERGY LABELING oratory. RULE’’) EFFECT OF THIS PART SCOPE 305.30 Effect on other law. 305.31 Stayed or invalid parts. Sec. 305.32 [Reserved] 305.1 Scope of the regulations in this part. APPENDIX A1 TO PART 305—REFRIGERATORS DEFINITIONS WITH AUTOMATIC DEFROST APPENDIX A2 TO PART 305—REFRIGERATORS 305.2 Definitions. AND REFRIGERATOR-FREEZERS WITH MAN- 305.3 Description of appliances and con- UAL DEFROST sumer electronics. APPENDIX A3 TO PART 305—REFRIGERATOR- 305.4 Description of furnaces and central air FREEZERS WITH PARTIAL AUTOMATIC DE- conditioners. FROST 305.5 Description of lighting products. APPENDIX A4 TO PART 305—REFRIGERATOR- 305.6 Description of plumbing products. FREEZERS WITH AUTOMATIC DEFROST GENERAL WITH TOP-MOUNTED FREEZER NO THROUGH-THE-DOOR ICE 305.7 Prohibited acts. APPENDIX A5 TO PART 305—REFRIGERATOR- FREEZERS WITH AUTOMATED DEFROST TESTING WITH SIDE-MOUNTED FREEZER NO 305.8 Determinations of estimated annual THROUGH-THE-DOOR ICE energy consumption, estimated annual APPENDIX A6 TO PART 305—REFRIGERATOR- operating cost, and energy efficiency rat- FREEZERS WITH AUTOMATED DEFROST ing, water use rate, and other required WITH BOTTOM-MOUNTED FREEZER NO disclosure content. THROUGH-THE-DOOR ICE 305.9 Duty to provide labels on websites. APPENDIX A7 TO PART 305—REFRIGERATOR- 305.10 Determinations of capacity. FREEZERS WITH AUTOMATIC DEFROST 305.11 Submission of data.
    [Show full text]
  • Your Fluorescence Microscope Transmitted-Light
    Your Fluorescence Microscope Transmitted-light. Bright-field Bright-field microscopy = Transmitted-light INVERTED UPRIGHT Fluorescence microscopy = Reflected-light Mercury Lamp Heat Filter Emission Filter Mirror Excitation Filter Collimating Lens Dichromatic Mirror (From:http://micro.magnet.fsu.edu) You need to know … Your light source Your filters Your objective Your detector Spectrum of a Mercury Lamp Your Light Source • Mercury lamp Wavelength (nm) • Xenon lamp Spectrum of a Xenon Lamp • Metal halide lamp • Halogen lamp • LED • Laser Wavelength (nm) (Modified from: h6p://www.cairn-research.co.uk) Your Light Source 1) Halogen lamp 2) Mercury lamp 3) Xenon lamp 4) Metal halide lamp 5) LED 6) Laser Tungsten – Halogen lamp • White light source • Inexpensive long lasNng bulbs • Used mainly for brighQield illuminaNon • CAN be used for fluorescence excitaNon above 400nm • Ideal for live cell imaging (low power, no UV) • “Colour” changes with temperature Mercury (HBO) lamp PROS • white light source • 10-100x brighter then halogen • focused intensity light-source • very bright intensity peaks at specific wavelengths for many standard fluoreophores CONS • short bulb life (≈200-400h) • generates a lot of heat • requires bulb alignment • no uniform intensity (peaks) • bulb are hazardous waste • long warm-up time • excitation wavelength cannot be • Intensity decay over Nme, intensity controlled independently flickering Xenon lamp PROS • white light source • relaNvely even intensity across visible spectrum • focused intense light source CONS • requires bulb alignment • bulbs are hazardous waste • Intensity decay over Nme • weaker intensity in UV • generates a lot of heat in the IR region • relaNvely low power in visible range • excitaNon wavelength cannot be controlled independently Metal Halide lamp PROS • white light source • brighter intensity between peaks than mercury lamp • no bulb alignment, more uniform field of illum.
    [Show full text]
  • Fluorescence Cell Imaging and Manipulation Using Conventional Halogen Lamp Microscopy
    Fluorescence Cell Imaging and Manipulation Using Conventional Halogen Lamp Microscopy Kazuo Yamagata1,2, Daisaku Iwamoto3, Yukari Terashita1,4, Chong Li1, Sayaka Wakayama1,Yoko Hayashi-Takanaka5, Hiroshi Kimura5, Kazuhiro Saeki3, Teruhiko Wakayama1* 1 RIKEN Center for Developmental Biology, Kobe, Japan, 2 Research Institute for Microbial Research, Osaka University, Suita, Japan, 3 Department of Genetic Engineering, Kinki University, Kinokawa, Wakayama, Japan, 4 Laboratory of Animal Reproduction, Graduate School of Agricultural Science, Tohoku University, Sendai, Japan, 5 Graduate School of Frontier Biosciences, Osaka University, Suita, Japan Abstract Technologies for vitally labeling cells with fluorescent dyes have advanced remarkably. However, to excite fluorescent dyes currently requires powerful illumination, which can cause phototoxic damage to the cells and increases the cost of microscopy. We have developed a filter system to excite fluorescent dyes using a conventional transmission microscope equipped with a halogen lamp. This method allows us to observe previously invisible cell organelles, such as the metaphase spindle of oocytes, without causing phototoxicity. Cells remain healthy even after intensive manipulation under fluorescence observation, such as during bovine, porcine and mouse somatic cell cloning using nuclear transfer. This method does not require expensive epifluorescence equipment and so could help to reduce the science gap between developed and developing countries. Citation: Yamagata K, Iwamoto D, Terashita Y, Li C, Wakayama S, et al. (2012) Fluorescence Cell Imaging and Manipulation Using Conventional Halogen Lamp Microscopy. PLoS ONE 7(2): e31638. doi:10.1371/journal.pone.0031638 Editor: Sue Cotterill, St. Georges University of London, United Kingdom Received September 12, 2011; Accepted January 10, 2012; Published February 8, 2012 Copyright: ß 2012 Yamagata et al.
    [Show full text]
  • Flashlight Ebook
    FLASHLIGHT PDF, EPUB, EBOOK Lizi Boyd | 40 pages | 12 Aug 2014 | CHRONICLE BOOKS | 9781452118949 | English | California, United States Flashlight PDF Book App Store Preview. The source of the light often used to be an incandescent light bulb lamp but has been gradually replaced by light-emitting diodes LEDs since the mids. Some models of flashlight include an acceleration sensor to allow them to respond to shaking, or to select modes based on what direction the light is held when switched on. LED flashlights were made in the early s. Perf Power. This was the first battery suitable for portable electrical devices, as it did not spill or break easily and worked in any orientation. CS1 maint: archived copy as title link U. Water resistance, if specified, is evaluated after impact testing; no water is to be visible inside the unit and it must remain functional. The standard described only incandescent lamp flashlights and was withdrawn in Colored light is occasionally useful for hunters tracking wounded game after dusk, or for forensic examination of an area. Solar powered flashlights use energy from a solar cell to charge an on-board battery for later use. Remove All. Don't feel overwhelmed with our surplus of options. Retailer Walmart. Anodized Aluminum. A flashlight may have a red LED intended to preserve dark adaptation of vision. Price Free. And it even goes with a compass, giving you the direction in the darkness. Lanterns Lanterns. The working distance is from the point of view of the user of the flashlight. An IP X8 rating by FL1 does not imply that the lamp is suitable for use as a diver's light since the test protocol examines function of the light only after immersion, not during immersion.
    [Show full text]
  • Basic Physics of the Incandescent Lamp (Lightbulb) Dan Macisaac, Gary Kanner,Andgraydon Anderson
    Basic Physics of the Incandescent Lamp (Lightbulb) Dan MacIsaac, Gary Kanner,andGraydon Anderson ntil a little over a century ago, artifi- transferred to electronic excitations within the Ucial lighting was based on the emis- solid. The excited states are relieved by pho- sion of radiation brought about by burning tonic emission. When enough of the radiation fossil fuels—vegetable and animal oils, emitted is in the visible spectrum so that we waxes, and fats, with a wick to control the rate can see an object by its own visible light, we of burning. Light from coal gas and natural say it is incandescing. In a solid, there is a gas was a major development, along with the near-continuum of electron energy levels, realization that the higher the temperature of resulting in a continuous non-discrete spec- the material being burned, the whiter the color trum of radiation. and the greater the light output. But the inven- To emit visible light, a solid must be heat- tion of the incandescent electric lamp in the ed red hot to over 850 K. Compare this with Dan MacIsaac is an 1870s was quite unlike anything that had hap- the 6600 K average temperature of the Sun’s Assistant Professor of pened before. Modern lighting comes almost photosphere, which defines the color mixture Physics and Astronomy at entirely from electric light sources. In the of sunlight and the visible spectrum for our Northern Arizona University. United States, about a quarter of electrical eyes. It is currently impossible to match the He received B.Sc.
    [Show full text]
  • Single Ended Lamp
    SINGLE-ENDEDSINGLE-ENDED LAMPLAMP The Short Arc Gap USHIO’s Sōlarc® single-ended lamps allow the equipment designer to capitalize on the lamp’s unique short arc length. At 1.27mm, with a peak luminance at the cathode, the lamp begins to approximate a point source. Coupled with carefully designed lenses or reflectors with maximum light capture and the appropriate focus, the lamp can deliver high-intensity light to tightly controlled or divergent beam applications. The figure below shows the luminous intensity distribution of the arc. The two sources of peak intensity lie near the electrode tips. Highest Efficacy Metal halide lamps are inherently very efficient, providing two to three times the efficacy of either halogen or xenon lamps. Optimizing the optical system using the short arc can provide an efficiency increase in many applications, allow- ing the Sōlarc lamp to deliver as much light as a halogen lamp with four to five times more wattage. High efficacy plus the resultant decreased demand for power allow the equipment designer to develop miniature, lighter weight, portable and even battery-powered product configurations. White Light Sōlarc lamps produce a color temperature in the range of 5,000K–7,000K, putting it in the same range as the sun. For comparison, halogen lamps normally operate in the 3,000K–3,200K range and incandescent lamps in the 2,800K- 2,900K range. In visible terms, the lower color temperature dictates more red or yellow in the light. The higher color temperature enables realistic visualization of color. While it is possible to operate halogen lamps up to 4,300K by the use of filters, it is only at a severe reduction in lamp life and output.
    [Show full text]
  • Incandescent Light Bulbs – Compact Fluorescent Lamps Questions and Answers
    FAQ Incandescent light bulbs / Compact fluorescent lamps August 2011 --------------------------------------- Incandescent light bulbs – Compact fluorescent lamps Questions and answers Overview Why are 60-watt incandescent bulbs being withdrawn from sale from 1 September 2011? ............. 1 What different types of lamp are there? ............................................................................................. 2 How much electricity do the different types of lamp use? .................................................................. 3 Why are some compact fluorescent lamps only in energy efficiency class B? .................................. 3 Where can compact fluorescent lamps be used? .............................................................................. 3 How long do compact fluorescent lamps last (burn time and number of on/off cycles)? ................... 4 Are there compact fluorescent lamps that emit light whose warmth is similar to that of incandescent bulbs? ........................................................................................................................... 4 How do I find the right compact fluorescent lamp to replace my old light bulb? ................................ 5 How long do compact fluorescent lamps take to reach full brightness after switching on? ............... 6 Compact fluorescent lamps are considerably more expensive than comparable incandescent bulbs. Why are the total annual costs so much lower despite this? ............................ 6 Compact fluorescent lamps
    [Show full text]
  • Metal Halide Lamps
    ABOUT LITETRONICS 2-6 LED 7-16 DECORATIVE A-LINE PARFECTION BR FLUORESCENT 17-40 ENERGY-LITE PFT NEOLITE SPIRAL-LITE SPIRAL-PAR TABLE OF CONTENTS MICRO-BRITE HID 41-48 SUPER ARC METAL HALIDE SUPER ARC PULSE-START METAL HALIDE SUPER ARC HIGH PRESSURE SODIUM HALOGEN 49-58 LITEPAR XTRA-LIFE FROST PAR SUPER SAFE-T COOL RAY SURE BEAM MIRRO ECONO OMNI-LITE INCANDESCENT 59-69 800.860.3392 | litetronics.com BONUS-LIFE ROUGH SERVICE MINI-BRITE DURO-LITE GLOSSARY 70-75 COVER ART Image Credit: NASA "Visible Earth" is an actual photograph taken from space, and is the most detailed, true-color photo of the entire Earth to date. LAMP SHAPE MEASUREMENT 77 © 2012 LITETRONICS International, Inc. 1 COMPANY HISTORY Litetronics was founded in 1970. For over forty years, it has successfully led the industry in the development, marketing, and servicing of green lighting solutions. The rapid growth of Litetronics, from a localized direct sales organization into an international company, refl ects its business strategy of capitalizing on emerging lighting technologies to create unique, market-driven products. Growth has come primarily by concentrating on the worldwide multi-billion dollar commercial lighting market. This market has responded favorably to Litetronics’ energy effi cient, long-lasting, green lighting solutions. Litetronics created a tradition of innovation with its 20,000-hour Super Service incandescent light bulbs. In 1986, Litetronics introduced the Litepar halogen lamp family to its product mix. Three years later, Litetronics engineered the Xtra-Life halogen lamp with an average life of 5,000 hours, which is still the longest life halogen lamp available on the market.
    [Show full text]
  • Simulate a 'Sun' for Solar Research
    EKV 01/14 Simulate a ‘Sun’ for Solar Research: A Literature Review of Solar Simulator Technology Wujun Wang Literature Review 2014 Department of Energy Technology Division of Heat and Power Technology Royal Institute of Technology Stockholm, Sweden Dept of Energy Technology Div of Heat and Power Technology Royal Institute of Technology SE-100 44 Stockholm, Sweden Tel: int +46 8 790 74 89 (secretary) Contents Keywords ................................................................................................................................................ 2 Nomenclature .......................................................................................................................................... 2 1. Introduction ................................................................................................................................... 3 2. Classification .................................................................................................................................. 4 2.1. Space solar simulator ............................................................................................................. 4 2.2. Standard solar simulator for terrestrial PV cell testing ........................................................ 6 2.3. Large scale solar simulator for solar collector testing .......................................................... 8 2.4. High-flux solar simulator (HFSS) for CSP and CPV research ........................................... 9 3. Main components .......................................................................................................................
    [Show full text]
  • A Detailed Review on Types of Lamps and Their Applications JOURNAL
    JOURNAL OF PHYSICAL AND CHEMICAL SCIENCES Journal homepage: http://scienceq.org/Journals/JPCS.php Review Open Access A Detailed Review on Types of lamps and their applications Askari Mohammad Bagher Department of Physics, Payame Noor University, Tehran, Iran *Corresponding author: Askari Mohammad Bagher, E-mail: [email protected] Received: December 9, 2015, Accepted: January 2, 2016, Published: January 2, 2016. ABSTRACT An electric light is a device that produces visible light by the flow of electric current. It is the most common form of artificial lighting and is necessary to modern society, providing interior lighting for buildings and exterior light for evening and nighttime activities. Types of lamps also have many applications in various sciences. This paper will study the lamps and their applications. Keywords: Incandescent light bulb, Halogen lamp, LED lamp, Fluorescent lamp, Carbon arc lamp, Discharge lamp . INTRODUCTION Before electric lighting became common in the early 20th century, people used oil lamps, gas lights, candles, and fires. Extensive use of electric lighting began with the invention of the first practical incandescent lamp by Thomas Edison and Joseph Swan in the nineteenth century Since then there have been Considerable improvements in lamp efficiency also the different types of lamp. As discussed in the overview, light sources used today can be divided into two main groups: incandescent and luminescent gas serous discharge lamps. The gaseous discharge type of lamp is either high or low pressure. Low-pressure gaseous discharge sources are the fluorescent and low-pressure sodium lamps Mercury vapor, metal halide and high-pressure sodium lamps are intended high-pressure gaseous discharge sources.
    [Show full text]
  • 100301 Style RX Page Par Page.Indd
    Operating Manual Style RX 300 Style RX 600 Style RX 1200 Version 230V - 20625 Version 230V - 20626 Version 230V - 20627 120V - 20725 120V - 20726 120V - 20727 Canada 120V - 20725.1VS Canada 120V - 20726.1VS Canada 120V - 20727.1VS Elinchrom S.A Style RX 01.03.2010 ENG (73253) Printed in Switzerland English Table of contents Introduction 2 Declaration of conformity, disposal and recycling, CE marking 3 Safety notice and precaution 4 Operating instructions 5 Control Panel 6 Switch and Fuse 7 Modelling Light 8 Digital power display, Photo-cell 9 Synchronisation, Wireless Remote control and flash triggering 10 Acoustic signal 10 Troubleshooting 7, 10 Flash tube replacement 11 Technical Data 12 Elinchrom Accessories 13 Guarantee 14 P.S: Technical data subject to change. The listed values are guide values which may vary due to tolerances in components used. 1 Introduction The Elinchrom Style RX is manufactured by Elinchrom S.A. CH -1020 Renens/Switzerland Dear Photographer, Thank you for buying your Style RX compact flash unit. All Elinchrom products are manufactured using the most advanced technology. Carefully selected components are used to ensure the highest quality and the equipment is submitted to many controls both during and after manufacture. We trust that it will give you many years of reliable service. All Style RX flash units are manufactured for the studio and location use of professional photographers. Only by observance of the information given, can you secure your warranty, prevent possible damage and increase the life of this equipment. Style 300RX - 600RX - 1200RX The quality of light and exceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area.
    [Show full text]
  • An Optically Stabilized Fast-Switching Light Emitting Diode As a Light Source for Functional Neuroimaging
    An Optically Stabilized Fast-Switching Light Emitting Diode as a Light Source for Functional Neuroimaging Daniel A. Wagenaar* Broad Fellows Program and Division of Biology, California Institute of Technology, Pasadena, California, United States of America Abstract Neuroscience research increasingly relies on optical methods for evoking neuronal activity as well as for measuring it, making bright and stable light sources critical building blocks of modern experimental setups. This paper presents a method to control the brightness of a high-power light emitting diode (LED) light source to an unprecedented level of stability. By continuously monitoring the actual light output of the LED with a photodiode and feeding the result back to the LED’s driver by way of a proportional-integral controller, drift was reduced to as little as 0.007% per hour over a 12-h period, and short-term fluctuations to 0.005% root-mean-square over 10 seconds. The LED can be switched on and off completely within 100 ms, a feature that is crucial when visual stimuli and light for optical recording need to be interleaved to obtain artifact-free recordings. The utility of the system is demonstrated by recording visual responses in the central nervous system of the medicinal leech Hirudo verbana using voltage-sensitive dyes. Citation: Wagenaar DA (2012) An Optically Stabilized Fast-Switching Light Emitting Diode as a Light Source for Functional Neuroimaging. PLoS ONE 7(1): e29822. doi:10.1371/journal.pone.0029822 Editor: Bjo¨rn Brembs, Freie Universitaet Berlin, Germany Received September 5, 2011; Accepted December 6, 2011; Published January 6, 2012 Copyright: ß 2012 Daniel A.
    [Show full text]