Storage Manager

Setup and User’s Guide

for Digidesign® DigiDrive® and Avid® Hard Drives

™ make manage move | media Avid ®

Copyright and Disclaimer Product specifications are subject to change without notice and do not represent a commitment on the part of Avid Technology, Inc.

The software described in this document is furnished under a license agreement. You can obtain a copy of that license by visiting Avid's Web site at www.avid.com. The terms of that license are also available in the product in the same directory as the software. The software may not be reverse assembled and may be used or copied only in accordance with the terms of the license agreement. It is against the law to copy the software on any medium except as specifically allowed in the license agreement.

Avid products or portions thereof are protected by one or more of the following United States Patents: 4,746,994; 4,970,663; 5,045,940; 5,267,351; 5,309,528; 5,355,450; 5,396,594; 5,440,348; 5,452,378; 5,467,288; 5,513,375; 5,528,310; 5,557,423; 5,577,190; 5,584,006; 5,640,601; 5,644,364; 5,654,737; 5,715,018; 5,724,605; 5,726,717; 5,729,673; 5,745,637; 5,752,029; 5,754,851; 5,799,150; 5,812,216; 5,828,678; 5,842,014; 5,852,435; 5,987,501; 6,061,758; 6,223,211; 6,301,105; 6,532,043; 6,546,190; 6,636,869; 6,747,705, 6,763,523; 6,813,622. Other patents are pending.

This document is protected under copyright law. An authorized licensee of Storage Manager may reproduce this publication for the licensee’s own use in learning how to use the software. This document may not be reproduced or distributed, in whole or in part, for commercial purposes, such as selling copies of this document or providing support or educational services to others. This document is supplied as a guide for Storage Manager. Reasonable care has been taken in preparing the information it contains. However, this document may contain omissions, technical inaccuracies, or typographical errors. Avid Technology, Inc. does not accept responsibility of any kind for customers’ losses due to the use of this document. Product specifications are subject to change without notice. Copyright © 2007 Avid Technology, Inc. and its licensors. All rights reserved. Printed in USA. The following disclaimer is required by Apple Computer, Inc. APPLE COMPUTER, INC. MAKES NO WARRANTIES WHATSOEVER, EITHER EXPRESS OR IMPLIED, REGARDING THIS PRODUCT, INCLUDING WARRANTIES WITH RESPECT TO ITS MERCHANTABILITY OR ITS FITNESS FOR ANY PARTICULAR PURPOSE. THE EXCLUSION OF IMPLIED WARRANTIES IS NOT PERMITTED BY SOME STATES. THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY PROVIDES YOU WITH SPECIFIC LEGAL RIGHTS. THERE MAY BE OTHER RIGHTS THAT YOU MAY HAVE WHICH VARY FROM STATE TO STATE. The following disclaimer is required by Sam Leffler and Silicon Graphics, Inc. for the use of their TIFF library: Copyright © 1988–1997 Sam Leffler Copyright © 1991–1997 Silicon Graphics, Inc.

Permission to use, copy, modify, distribute, and sell this software [i.e., the TIFF library] and its documentation for any purpose is hereby granted without fee, provided that (i) the above copyright notices and this permission notice appear in all copies of the software and related documentation, and (ii) the names of Sam Leffler and Silicon Graphics may not be used in any advertising or publicity relating to the software without the specific, prior written permission of Sam Leffler and Silicon Graphics.

THE SOFTWARE IS PROVIDED “AS-IS” AND WITHOUT WARRANTY OF ANY KIND, EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.

The following disclaimer is required by the Independent JPEG Group: Portions of this software are based on the work of the Independent JPEG Group.

This Software may contain components licensed under the following conditions:

Copyright © 1989 The Regents of the University of California. All rights reserved.

Redistribution and use in source and binary forms are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that the software was developed by the University of California, Berkeley. The name of the University may not be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

2 Copyright © 1989, 1991 by Jef Poskanzer.

Permission to use, copy, modify, and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appear in all copies and that both that copyright notice and this permission notice appear in supporting documentation. This software is provided "as is" without express or implied warranty.

Copyright 1995, Trinity College Computing Center. Written by David Chappell.

Permission to use, copy, modify, and distribute this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notice appear in all copies and that both that copyright notice and this permission notice appear in supporting documentation. This software is provided "as is" without express or implied warranty.

Copyright 1996 Daniel Dardailler.

Permission to use, copy, modify, distribute, and sell this software for any purpose is hereby granted without fee, provided that the above copyright notice appear in all copies and that both that copyright notice and this permission notice appear in supporting documentation, and that the name of Daniel Dardailler not be used in advertising or publicity pertaining to distribution of the software without specific, written prior permission. Daniel Dardailler makes no representations about the suitability of this software for any purpose. It is provided "as is" without express or implied warranty.

Modifications Copyright 1999 Matt Koss, under the same license as above.

Copyright © 1991 by AT&T.

Permission to use, copy, modify, and distribute this software for any purpose without fee is hereby granted, provided that this entire notice is included in all copies of any software which is or includes a copy or modification of this software and in all copies of the supporting documentation for such software.

THIS SOFTWARE IS BEING PROVIDED "AS IS", WITHOUT ANY EXPRESS OR IMPLIED WARRANTY. IN PARTICULAR, NEITHER THE AUTHOR NOR AT&T MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND CONCERNING THE MERCHANTABILITY OF THIS SOFTWARE OR ITS FITNESS FOR ANY PARTICULAR PURPOSE.

This product includes software developed by the University of California, Berkeley and its contributors. The following disclaimer is required by Nexidia Inc.: © 2006 Nexidia. All rights reserved.

Manufactured under license from the Georgia Tech Research Corporation, U.S.A. Patent Pending. The following disclaimer is required by Paradigm Matrix: Portions of this software licensed from Paradigm Matrix. The following disclaimer is required by Ray Sauers Associates, Inc.: “Install-It” is licensed from Ray Sauers Associates, Inc. End-User is prohibited from taking any action to derive a source code equivalent of “Install-It,” including by reverse assembly or reverse compilation, Ray Sauers Associates, Inc. shall in no event be liable for any damages resulting from reseller’s failure to perform reseller’s obligation; or any damages arising from use or operation of reseller’s products or the software; or any other damages, including but not limited to, incidental, direct, indirect, special or consequential Damages including lost profits, or damages resulting from loss of use or inability to use reseller’s products or the software for any reason including copyright or patent infringement, or lost data, even if Ray Sauers Associates has been advised, knew or should have known of the possibility of such damages. The following disclaimer is required by Videomedia, Inc.: “Videomedia, Inc. makes no warranties whatsoever, either express or implied, regarding this product, including warranties with respect to its merchantability or its fitness for any particular purpose.”

“This software contains V-LAN ver. 3.0 Command Protocols which communicate with V-LAN ver. 3.0 products developed by Videomedia, Inc. and V-LAN ver. 3.0 compatible products developed by third parties under license from Videomedia, Inc. Use of this software will allow “frame accurate” editing control of applicable recorder decks, recorders/players and the like.” The following disclaimer is required by Altura Software, Inc. for the use of its Mac2Win software and Sample Source Code: ©1993–1998 Altura Software, Inc. The following disclaimer is required by Ultimatte Corporation: Certain real-time compositing capabilities are provided under a license of such technology from Ultimatte Corporation and are subject to copyright protection.

3

The following disclaimer is required by 3Prong.com Inc.: Certain waveform and vector monitoring capabilities are provided under a license from 3Prong.com Inc. The following disclaimer is required by Interplay Entertainment Corp.: The “Interplay” name is used with the permission of Interplay Entertainment Corp., which bears no responsibility for Avid products.

This product includes portions of the Alloy Look & Feel software from Incors GmbH.

This product includes software developed by the Apache Software Foundation (http://www.apache.org/).

© DevelopMentor This product may include the JCifs library, for which the following notice applies: JCifs © Copyright 2004, The JCIFS Project, is licensed under LGPL (http://jcifs.samba.org/). See the LGPL.txt file in the Third Party Software directory on the installation CD.

Avid Interplay contains components licensed from LavanTech. These components may only be used as part of and in connection with Avid Interplay.

Attn. Government User(s). Restricted Rights Legend

U.S. GOVERNMENT RESTRICTED RIGHTS. This Software and its documentation are “commercial computer software” or “commercial computer software documentation.” In the event that such Software or documentation is acquired by or on behalf of a unit or agency of the U.S. Government, all rights with respect to this Software and documentation are subject to the terms of the License Agreement, pursuant to FAR §12.212(a) and/or DFARS §227.7202-1(a), as applicable. Trademarks 888 I/O, Adrenaline, AirPlay, AirSPACE, AirSPACE HD, AirSpeed, AniMatte, AudioSuite, AudioVision, AutoSync, Avid, Avid DNA, Avid DNxcel, Avid DNxHD, AVIDdrive, AVIDdrive Towers, Avid DS Assist Station, Avid ISIS, Avid Learning Excellerator, Avid Liquid, Avid Mojo, AvidNet, AvidNetwork, Avid Remote Response, AVIDstripe, Avid Unity, Avid Unity ISIS, Avid Xpress, AVoption, AVX, CamCutter, ChromaCurve, ChromaWheel, DAE, Dazzle, Deko, DekoCast, D-Fi, D-fx, DigiDelivery, Digidesign, Digidesign Audio Engine, Digidesign Intelligent Noise Reduction, DigiDrive, Digital Nonlinear Accelerator, DigiTranslator, DINR, DNxchange, do more, D-Verb, Equinox, ExpertRender, Face Robot, FieldPak, Film Composer, FilmScribe, FluidMotion, FXDeko, HIIP, HyperSPACE, HyperSPACE HDCAM, IllusionFX, Image Independence, iNEWS, iNEWS ControlAir, Instinct, Interplay, Intraframe, iS9, iS18, iS23, iS36, LaunchPad, Lightning, Lo-Fi, Magic Mask, make manage move | media, Marquee, Matador, Maxim, MCXpress, Media Browse, Media Composer, MediaDock, MediaDock Shuttle, Media Fusion, Media Illusion, MediaLog, Media Reader, Media Recorder, MEDIArray, MediaShare, MediaStream, Meridien, MetaSync, MissionControl, NaturalMatch, Nearchive, NetReview, NewsCutter, Nitris, OMF, OMF Interchange, OMM, Open Media Framework, Open Media Management, PCTV, Pinnacle MediaSuite, Pinnacle Studio, Pinnacle Systems, ProEncode, Pro Tools, QuietDrive, Recti-Fi, RetroLoop, rS9, rS18, Sci-Fi, ScriptSync, SecureProductionEnvironment, Show Center, Softimage, Sound Designer II, SPACE, SPACEShift, SpectraGraph, SpectraMatte, SteadyGlide, Symphony, TARGA, Thunder, Trilligent, UnityRAID, Vari-Fi, RAID, Video Slave Driver, VideoSPACE, and Xdeck are either registered trademarks or trademarks of Avid Technology, Inc. in the United States and/or other countries.

Adobe and Photoshop are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries. Apple and Macintosh are trademarks of Apple Computer, Inc., registered in the U.S. and other countries. Windows is either a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. All other trademarks contained herein are the property of their respective owners.

Storage Manager Setup and User’s Guide • Part 0130-05454-01 Rev. E • January 2007

4 Contents

Using This Guide ...... 9 Symbols and Conventions ...... 9 If You Need Help...... 10 How to Order Documentation ...... 11 Avid Training Services ...... 11 Chapter 1 Installing Storage Manager ...... 13 Determining If Storage Manager Is Installed...... 13 Installing Storage Manager (Windows) ...... 14 Installing Storage Manager (Macintosh) ...... 14 Chapter 2 Storage Manager Overview ...... 15 Introduction ...... 15 Understanding IDs ...... 16 The Main Window ...... 18 Physical View ...... 18 Adapter Board Description ...... 19 Converter or RAID Controller Description ...... 19 Hard Drive Description ...... 20 Unit Indicator ...... 21 Availability/Testing Status Indicator...... 21 Partition Status Indicator ...... 22 Volume View ...... 24 Raw Drives List ...... 24 Volume Name ...... 25 Mount Status Indicator...... 25 RAID Enclosures ...... 26 Stripe Set Drive Total ...... 26 Toolbars and Menus ...... 26 Top Toolbar and Menu Equivalents ...... 26 Side Toolbar ...... 28 Using Storage Manager with Other Utilities ...... 29 Chapter 3 Using Storage Manager ...... 31 Opening and Closing Storage Manager...... 31 Setting User Preferences ...... 32 Window User Preferences...... 33 View User Preferences ...... 33 E-mail User Preferences ...... 34 Selecting Hard Drives...... 35 Selecting a Single Drive ...... 35 Selecting Multiple Drives ...... 35 Viewing Hard Drive Information ...... 36 Viewing Hardware Information ...... 36 Viewing Volume Information ...... 41 Identifying Hard Drives...... 42 Spinning Down Hard Drives ...... 43 Rescanning the Storage Subsystem ...... 43 Saving the Storage Subsystem Configuration ...... 44 Sending Error Log and Configuration Files ...... 45 Updating Hard Drive Firmware...... 46 Obtaining an Updated Firmware Package...... 46 Updating Hard Drives ...... 47 Chapter 4 Tuning Digidesign Drives ...... 49 Pro Tools System Prerequisites (Windows)...... 50 Pro Tools System Prerequisites (Macintosh) ...... 50 Using the Storage Manager Drive Tuner ...... 50 Chapter 5 Testing Hard Drives ...... 51 Nondestructive and Destructive Tests ...... 51 Testing Your Hard Drives...... 52 Using a Test Template ...... 52 Creating a Custom Test ...... 53 Running a Test ...... 54

6 Viewing Test Information ...... 55 Test Templates ...... 58 Test Parameters ...... 60 Error Messages...... 66 Appendix A Interpreting Error Messages ...... 67 Error Messages and Corrective Actions ...... 67 Index ...... 71

7 8 Using This Guide

Storage Manager is a general-purpose, administrative utility for updating, testing, and troubleshooting storage media (Avid® drives and Digidesign® DigiDrive® drives only) connected to Avid or Digidesign systems. Storage Manager is available for the following operating systems: •Windows® 2000 and Windows® XP operating systems running on an Avid Unity MediaNetwork client or as a standalone system •Mac OS® X operating system running on a standalone system

This guide is intended for administrators responsible for installing, testing, and troubleshooting Avid and DigiDrive hard drives.

Unless noted otherwise, the material in this document applies to the Windows XP and Mac OS X operating systems.The majority of screen shots in this document were captured on a Windows XP system, but the information applies to both Windows XP and Mac OS X systems. Where differences exist, both Windows XP and Mac OS X screen shots are shown. n The documentation describes the features and hardware of all models. Therefore, your system might not contain certain features and hardware that are covered in the documentation.

Symbols and Conventions

Unless noted otherwise, the name “Storage Manager” applies to both Avid Storage Manager and Digidesign Storage Manager.

Unless noted otherwise, the material in this document applies to the Windows and Macintosh® operating systems. When the text applies to a specific operating system, it is marked as follows: • (Windows) or (Windows only) means the information applies to the Windows NT, Windows 2000, and Windows XP operating systems. • (Macintosh) or (Macintosh only) means the information applies to the Mac OS X operating system. Using This Guide

The majority of screen shots in this document were captured on a Windows XP system, but the information applies to both Windows and Macintosh systems. Where differences exist, both Windows and Macintosh screen shots are shown.

Avid documentation uses the following symbols and conventions:

Symbol or Convention Meaning or Action n A note provides important related information, reminders, recommendations, and strong suggestions. c A caution means that a specific action you take could cause harm to your computer or cause you to lose data. w A warning describes an action that could cause you physical harm. Follow the guidelines in this document or on the unit itself when handling electrical equipment.

> This symbol indicates menu commands (and subcommands) in the order you select them. For example, File > Import means to open the File menu and then select the Import command.

t This symbol indicates a single-step procedure. Multiple arrows in a list indicate that you perform one of the actions listed.

k This symbol represents the Apple or Command key. Press and hold the Command key and another key to perform a keyboard shortcut.

(Windows), (Windows only), This text indicates that the information applies only to the specified (Macintosh), or (Macintosh operating system, either Windows XP or Macintosh OS X. only)

Italic font Italic font is used to emphasize certain words and to indicate variables.

Courier Bold font Courier Bold font identifies text that you type.

Ctrl+key or mouse action Press and hold the first key while you press the last key or perform the k+key or mouse action mouse action. For example, k+Option+C or Ctrl+drag.

If You Need Help

If you are having trouble using Storage Manager: 1. Retry the action, carefully following the instructions given for that task in this guide. It is especially important to check each step of your workflow.

10 How to Order Documentation

2. Check for the latest information that might have become available after the documentation was published in one of two locations: - If release notes are available, they ship with your application. - If ReadMe files are available, they are supplied in your Avid application folder. ReadMe files are also available from Help. n Release notes and ReadMe files are also available on the Avid Knowledge Base. 3. Check the documentation that came with your Avid application or your hardware for maintenance or hardware-related issues. 4. Visit the online Knowledge Center at www.avid.com/support. Online services are available 24 hours per day, 7 days per week. Search this online Knowledge Center to find answers, to view error messages, to access troubleshooting tips, to download updates, and to read/join online message-board discussions. 5. For Technical Support, please call 800-800-AVID (800-800-2843). For Broadcast On-Air Sites and Call Letter Stations, call 800-NEWSDNG (800-639-7364).

How to Order Documentation

To order additional copies of this documentation from within the United States, call Avid Sales at 800-949-AVID (800-949-2843). If you are placing an order from outside the United States, contact your local Avid representative.

Avid Training Services

Avid makes lifelong learning, career advancement, and personal development easy and convenient. Avid understands that the knowledge you need to differentiate yourself is always changing, and Avid continually updates course content and offers new training delivery methods that accommodate your pressured and competitive work environment.

To learn about Avid's new online learning environment, Avid Learning Excellerator™ (ALEX), visit http://learn.avid.com.

For information on courses/schedules, training centers, certifications, courseware, and books, please visit www.avid.com/training or call Avid Sales at 800-949-AVID (800-949-2843).

11 Using This Guide

12 Chapter 1 Installing Storage Manager

This chapter explains how to install the Storage Manager utility on Avid systems that you use to test and update hard drives. Storage Manager is preinstalled on some Windows and Macintosh Avid systems. If it is preinstalled on your system, go to Storage Manager Overview. If it is not preinstalled, check either the installation CD-ROM that came with your Avid or DigiDrive hard drive or the Avid Web site (www.avid.com) for a standalone installer. c Storage Manager tests or tunes DigiDrive and Avid hard drives on Digidesign systems only. It cannot test or tune other hard drives. For Avid hard drives on other Avid systems, use the Avid Startup utility to tune drives.

This chapter includes the following topics: • Determining If Storage Manager Is Installed • Installing Storage Manager (Windows) • Installing Storage Manager (Macintosh)

Determining If Storage Manager Is Installed

To determine if Storage Manager is already installed: t (Windows) Click the Start button, and select Programs > Avid > Utilities > Avid Storage Manager. t (Macintosh) Navigate to Macintosh HD/Applications/Utilities/ Avid Storage Manager.

If it is properly installed, Storage Manager should open. If Storage Manager does not appear on the Start menu (Windows) or on the Macintosh HD (Macintosh), you need to install it. Chapter 1 Installing Storage Manager Installing Storage Manager (Windows)

If Storage Manager is not installed on your Avid system, you can install it from the Avid or Digidesign CD-ROM that came with your Avid or DigiDrive hard drive. If your CD-ROM does not contain a copy of Storage Manager, you can download the utility from the Avid Knowledge Base at www.avid.com. Once you have located the utility, perform the following procedure to install it on your Avid system. n Storage Manager runs on systems that use the Windows 2000 or Windows XP operating system. Functionality is reduced when you test Avid Unity LANshare or Avid Unity LANshare EX drives from a client.

To install Storage Manager on a Windows system: 1. Do one of the following: t Navigate to the CD-ROM drive:\AvidStorageManager folder, OR t Navigate to the location where you saved the Storage Manager download file. n The downloaded file is in a compressed format. You must uncompress the file before installing Storage Manager.

2. Double-click the Setup or Setup.exe icon. The Storage Manager Setup window opens. 3. Click Next to proceed with the installation. 4. Select the country in which you purchased Storage Manager, and then click Next. 5. Click Yes to accept the license agreement. 6. Click Next to install Storage Manager to its default location, C:\Program Files\Avid\Utilities\Avid Storage Manager. 7. Click Next to perform a default Storage Manager installation. 8. Click Finish to close the Storage Manager Setup window.

Installing Storage Manager (Macintosh)

Storage Manager installs when you install your Avid application on a Macintosh system. If it is not installed, check either the installation CD-ROM that came with your Avid or DigiDrive hard drive or the Avid Web site (www.avid.com) for a standalone installer.

14 Chapter 2 Storage Manager Overview

Click the links below to view topics that provide an overview of Storage Manager’s features and user interface. • Introduction • Understanding IDs • The Main Window • Toolbars and Menus • Using Storage Manager with Other Utilities

Introduction

Storage Manager is a utility you can use to work with Avid hard drives in your storage subsystem. Using Storage Manager, you can do the following: • Identify Avid hard drives. For more information, see “Identifying Hard Drives” on page 42. • Spin down Avid hard drives (SCSI and Fibre Channel only). For more information, see “Spinning Down Hard Drives” on page 43. • Report and share test results by generating log files and sending them by e-mail to recipients that you specify. For more information, see “Sending Error Log and Configuration Files” on page 45. • Update Avid hard drive firmware. For more information, see “Updating Hard Drive Firmware” on page 46. Chapter 2 Storage Manager Overview

• Tune DigiDrive drives for optimal performance using the Storage Manager Drive Tuner. This feature replaces the DigiDrive Tuner. For more information, see “Using the Storage Manager Drive Tuner” on page 50. • Exercise Avid hard drives using a variety of standardized or customized tests. For more information, see “Testing Your Hard Drives” on page 52. • Obtain test status information useful for troubleshooting. For more information, see “Viewing Test Information” on page 55.

In addition to these features, the Storage Manager user interface provides a main window with two views, Physical view and Volume view, that provide information about your storage subsystem. c Storage Manager tests or tunes DigiDrive and Avid hard drives on Digidesign systems only. It cannot test or tune other hard drives. For Avid hard drives on other Avid systems, use the Avid Startup utility to tune drives.

introduction overview

Related Topics Understanding IDs The Main Window Physical View Vo lu me View Toolbars and Menus Using Storage Manager with Other Utilities

Understanding IDs

All of the devices connected to an Avid system — for example, hard drives and CD-ROM drives — must have unique identification numbers (IDs). The Avid system uses these IDs to distinguish the devices from each other and to direct traffic between itself and the devices. There are different types of IDs, and this section provides a brief overview of each type. These IDs are used throughout the Storage Manager user interface.

Each ID contains three parts — the bus ID, the device ID, and the LUN ID: • Bus ID: Indicates the storage bus in the Avid system where drives connect. Storage Manager can identify and use storage buses on host bus adapter boards or the system board. Host bus adapter boards can have multiple storage buses.

16 Understanding IDs

• Device ID: Indicates an individual device connected to a storage bus. Each device must have a unique ID. You can attach many types of devices to a storage bus; however, Storage Manager uses only the device IDs for the hard drives in your storage subsystem. Device IDs are limited. A SCSI adapter board can accommodate 16 IDs. One ID is used for the SCSI bus adapter itself (typically ID 7), leaving 15 IDs for any hard drives connected to it. A Fibre Channel adapter board using a Fibre Channel arbitrated loop can accommodate 126 IDs. • LUN ID: Storage Manager uses the logical unit number ID (LUN ID) when you add a converter or RAID controller to your storage subsystem. Converters convert a bus’s drive interface from one type to another (for example, a SCSI bus to an IDE bus). Every hard drive attached to a converter has a unique LUN ID, and the converter has a device ID. RAID controllers map the storage connected to them into one or more storage groups identified by LUN IDs.

The following figure shows how IDs are assigned to devices attached to an Avid system.

Host bus Hard drives Hard drives adapter boards Device ID 0

Device ID 1

Device ID 2

Bus ID 0 Device ID 3 LUN ID 0 • LUN ID 1 Avid Bus ID 1 • system • LUN ID 2 Bus ID 2 Converter or LUN ID 3 Bus ID 3 RAID Controller Device ID 0 LUN ID 4 • • LUN ID 5 • LUN ID 6

LUN ID 7

• • •

adapter board ID IDs bus device LUN

17 Chapter 2 Storage Manager Overview The Main Window

Storage Manager’s main window provides a visual display of your storage subsystem along with several status indicators. The main window has two views, Physical view and Volume view, which allow you to look at your storage from a physical perspective or a logical perspective. n You cannot see Physical view and Volume view concurrently. For more information, see the following topics: • Physical View • Vo lu me View

Related Topics Top Toolbar and Menu Equivalents Side Toolbar

main physical volume view

Physical View

Physical view is the default view when Storage Manager opens (unless you reset the user preferences to Volume view). Physical view presents an expandable tree structure outlining the physical characteristics of your storage subsystem: all of the storage adapter boards in your Avid system, any converters or RAID controllers, and the attached hard drives. c Physical view shows your internal and external hard drives. Do not select the internal system drive when you are working with Storage Manager’s features. Drives that contain mounted volumes (visible in Volume view) can be selected but not tested.

For more information on Physical view features, see the following topics: • Adapter Board Description • Hard Drive Description • Availability/Testing Status Indicator • Partition Status Indicator • Unit Indicator

physical view

18 The Main Window

Related Topics Volu me View

Adapter Board Description

An adapter board description includes: • Bus ID (a bus on the Avid system where the hard drive is connected) • Manufacturer’s name • Model number

adapter adapters board boards bus ID IDs manufacturer model

Related Topics Hard Drive Description Converter or RAID Controller Description Availability/Testing Status Indicator Partition Status Indicator Unit Indicator

Converter or RAID Controller Description

A converter or RAID controller description appears in the branch beneath the adapter board to which it is connected. Converter and RAID controller descriptions branch again to display descriptions of all the hard drives connected to them. You can recognize a converter’s hard drives because their descriptions begin with LUN instead of HDD (). You can recognize a RAID controller’s hard drives because their descriptions include their RAID classification (RAID 0, RAID 5, or JBOD).

A converter or RAID controller description includes: • Converter or controller indicator icon • Bus ID, device ID, and LUN ID for the converter or controller • Manufacturer’s name • Model number • RAID classification

Related Topics Understanding IDs Adapter Board Description

19 Chapter 2 Storage Manager Overview

Hard Drive Description Availability/Testing Status Indicator Partition Status Indicator Unit Indicator

converter converters bus device devices LUN ID IDs manufacturer model

Hard Drive Description

A hard drive description includes: • Drive connection type. The drive connection type is either HDD, RAID, RAID member or LUN. HDD indicates that the hard drive is connected directly to the adapter board. LUN indicates that the hard drive is connected to the adapter board by way of a converter. RAID indicates it is the RAID controller. RAID member indicates it is one of the physical RAID drives. • Bus ID, device ID, and LUN ID for the hard drive. • Manufacturer’s name. •Model number. • Drive size, where 1 GB equals 1024 bytes x 1024 bytes x 1024 bytes. Drive sizes typically appear smaller than the manufacturer’s stated size because drive manufacturers state drive size in decimal billions of bytes.

Related Topics Understanding IDs Vo lu me View Adapter Board Description Converter or RAID Controller Description Availability/Testing Status Indicator Partition Status Indicator Unit Indicator

disk disks drive drives bus device devices LUN ID IDs HDD manufacturer model size

20 The Main Window

Unit Indicator

Each unit in the storage subsystem (hard drive, adapter board, converter, or RAID controller) has a drive icon.

Related Topics Volu me View Adapter Board Description Hard Drive Description Converter or RAID Controller Description Availability/Testing Status Indicator Partition Status Indicator

disk disks drive drives Fibre Channel FC SCSI IDE

Availability/Testing Status Indicator

To the left of the hard drive description is the availability/testing status indicator (see the following figure). The following table describes the various availability/testing status indications.

Availability/Testing Status Indicators

Status Description

Ready The hard drive is ready to read and write data.

Unavailable The device is not accessible. The drive might be turned off, spinning up, having a problem, or not supported (for example, it is a non-Avid drive). The device might be an enclosure or a CD-ROM drive that is not testable.

Testing The hard drive is currently being tested.

Passed The hard drive has passed its most recent test. n If the test aborts before the hard drive has failed, the status indication is Passed.

Failed The hard drive has failed its most recent test.

Updating Updated firmware is currently being downloaded to the hard drive (Windows only).

21 Chapter 2 Storage Manager Overview

Availability/Testing Status Indicators (Continued)

Status Description

Updated Firmware has been downloaded to the hard drive (Windows only).

Broken The hard drive is having a problem.

n Hard drives with an availability/testing status of Passed, Failed, or Updated change their status back to Ready when you rescan the storage subsystem. For more information on rescanning, see “Rescanning the Storage Subsystem” on page 43.

Related Topics Vo lu me View Adapter Board Description Hard Drive Description Converter or RAID Controller Description Partition Status Indicator Unit Indicator

availability testing status ready unavailable passed failed

Partition Status Indicator

To the right of the hard drive description is the partition status indicator (see the following figure). The following table describes the various partition status indicators.

Partition Status Indicators

Status Description

Raw The hard drive has no partition or file system information on it.

Unsupported The hard drive has an unsupported file system.

Mixed The hard drive has several partitions with different format types.

Remus The hard drive’s partition information indicates it was used for local Fibre Channel storage (Mac OS 9.x or earlier; drive format is not compatible with Mac OS X).

22 The Main Window

Partition Status Indicators (Continued)

Status Description

Remus Stripe The hard drive’s partition information indicates it was used for striped local Fibre Channel storage (Mac OS 9.x or earlier; drive format is not compatible with Mac OS X).

Apple The hard drive’s partition information indicates it was used as a boot drive for a Macintosh system (Mac OS 9.x or earlier).

ATTO The hard drive’s partition information indicates it was connected to a Macintosh system by an ATTO adapter board (Mac OS X).

ATTO Stripe The hard drive’s partition information indicates it was part of a stripe set connected to a Macintosh system by an ATTO adapter board (Mac OS X).

MediaNet Stripe The hard drive’s partition information indicates it was part of a MediaNetwork Fibre Channel shared storage environment.

FAT 16, FAT 32, The hard drive’s partition information indicates it has FAT 32 XINT13 been formatted for use in an MS-DOS environment (Windows).

LDM The hard drive’s partition information indicates it is a dynamic drive (Windows 2000 and Windows XP).

LDM Stripe The hard drive’s partition information indicates it is a stripe dynamic drive (Windows 2000 and Windows XP).

NTFT The hard drive’s partition information indicates it is part of a fault-tolerant partition (Windows 2000 and Windows XP).

NTFS Stripe The hard drive’s partition information indicates it is a stripe dynamic drive (Windows 2000 and Windows XP).

IFS The hard drive’s partition information indicates the drive has an older MS-DOS partition.

23 Chapter 2 Storage Manager Overview

Related Topics Vo lu me View Adapter Board Description Hard Drive Description Converter or RAID Controller Description Availability/Testing Status Indicator Unit Indicator

partition partitions format formatting formats status striped unstriped raw Remus ATTO Apple Unity FAT LDM extendedNTFT NTFS IFS

Volume View

Volume view presents an expandable tree structure with a logical view of the volumes you have created for your storage subsystem and the hard drives that make up those volumes.

Volume view has many of the same features as Physical view, such as: • Hard Drive Description • Availability/Testing Status Indicator • Partition Status Indicator • Unit Indicator

In addition to the list above, Volume view has four more features: • Raw Drives List • Vo lu me N am e • Mount Status Indicator • Stripe Set Drive Total

Related Topics Physical View

volume view

Raw Drives List

Volume view lists all of the unformatted drives in a Raw drives list. To view your raw drives, expand the Raw drives list.

24 The Main Window

Related Topics Volume Name Mount Status Indicator Stripe Set Drive Total

raw drive drives

Volume Name

Each volume has a specific name. A volume is a logical storage unit that either uses one physical drive or spans multiple drives. Volumes that span multiple drives are called stripe volumes. You can expand each volume name to show the drives that make up that volume.

Related Topics Raw Drives List Mount Status Indicator Stripe Set Drive Total

volume volumes name names

Mount Status Indicator

To the left of the volume name is the mount status indicator. The following table describes the various mount status indicators.

Mount Status Indicators

Status Description

Mounted The hard drive is currently mounted on your Avid system.

Unmounted The hard drive is not currently mounted on your Avid system.

Broken The volume is made up of multiple hard drives that are part of a stripe set, and one or more drives in the set are unavailable. If this status is shown for a raw drive, then the drive is having a problem.

Related Topics Raw Drives List Volume Name

25 Chapter 2 Storage Manager Overview

Stripe Set Drive Total

mount mounts mounting status mounted unmounted broken

RAID Enclosures

RAID enclosures display as separate volumes. Each volume expands to show the hard drives that comprise the RAID enclosure.

Stripe Set Drive Total

If a volume is comprised of a stripe set of drives, the number of drives in the set is shown to the left of the volume’s mount status indicator.

Related Topics Raw Drives List Volume Name Mount Status Indicator

striped set disk disks stripe drive drives

Toolbars and Menus

Storage Manager has two toolbars, one on the top and one on the side, which allow you to access features quickly and easily. All of the buttons in the top toolbar have menu equivalents that you can access from the menu bar.

Click a link below to view more information about Storage Manager’s toolbars: • Top Toolbar and Menu Equivalents • Side Toolbar

Related Topics The Main Window

toolbar toolbars menu menus

Top Toolbar and Menu Equivalents

The following table describes the buttons in the top toolbar and provides their equivalent menu commands.

26 Toolbars and Menus

Top Toolbar Buttons

Button Button Name Description Menu Equivalent

Physical View Displays Physical view in the main window. Select View > Physical.

Volume View Displays Volume view in the main window. Select View > Volume.

Console Opens the Console window, which allows you Select View > Console. to view test results and firmware updating results.

Rescan System Initiates a rescan of the entire storage Select Edit > Rescan Configuration subsystem, and updates Physical view and Configuration. Volume view with the results.

Update Firmware Initiates a firmware download to an Avid hard Select Edit > Update drive. Firmware.

User Preferences Opens the User Preferences dialog box, which Select Edit > User allows you to set the default behavior for a Preferences. variety of features.

Save Saves the current configuration of your storage Select File > Save Configuration subsystem. Avid Customer Support uses this Configuration. configuration file for diagnostic purposes.

Send File Opens the Send File dialog box, which allows Select File > Send File. you to send a log file by e-mail to a recipient you specify.

Exit Closes Storage Manager. Select File > Exit.

Help Displays Storage Manager Help contents. Select Help > Contents.

27 Chapter 2 Storage Manager Overview

Related Topics Side Toolbar

top toolbar toolbars menu menus

Side Toolbar

The following table describes the buttons in the side toolbar. These buttons do not have equivalent menu commands.

Side Toolbar Buttons

Button Button Name Description

Identify Identifies the hard drives currently selected in the main window by causing the drives’ activity LED to blink. n The Identify feature is not supported when you test Avid Unity LANshare or Avid Unity LANshare EX drives from a client.

Spin Down Spins down the shuttles currently selected in the main window in preparation for swapping the shuttles. This feature parks the heads, stops the disk rotation, and puts the drives in Idle mode. For more information on the Spin Down feature, see “Spinning Down Hard Drives” on page 43. n The Spin Down feature is not supported for IDE, IEEE 1394- compliant (FireWire), or MediaRAID drives.

Test Opens the Test window that you use to set up and run tests on your Avid hard drives.

Close Closes Physical view or Volume view, depending on which view is active.

Help Opens a context-sensitive Help window that contains information about the main window’s current view (Physical or Volume).

Related Topics Top Toolbar and Menu Equivalents

side toolbar toolbars

28 Using Storage Manager with Other Utilities Using Storage Manager with Other Utilities

You can use Storage Manager with other Avid configuration and diagnostic utilities designed to set up and troubleshoot your Avid components. These utilities include: • Avid System Test Pro: This utility tests the Avid editing system to make sure the Avid components and peripheral boards are functioning properly.

FILE INFO:AvidStartup: This utility ensures that the storage media performance parameters are set correctly for your Avid software.

29 Chapter 2 Storage Manager Overview

30 Chapter 3 Using Storage Manager

This section provides information on using Storage Manager’s features, except hard drive tuning and hard drive testing. For information on these topics, see the following sections: • Tuning Digidesign Drives • Testing Hard Drives

This section includes the following topics: • Opening and Closing Storage Manager • Setting User Preferences • Selecting Hard Drives • Viewing Hard Drive Information • Identifying Hard Drives • Spinning Down Hard Drives • Rescanning the Storage Subsystem • Saving the Storage Subsystem Configuration • Sending Error Log and Configuration Files • Updating Hard Drive Firmware

Opening and Closing Storage Manager

To open Storage Manager on a Windows system: t Click the Start button, and select Programs > Avid > Utilities > Avid Storage Manager. Chapter 3 Using Storage Manager

To open Storage Manager on a Macintosh system: t Navigate to Macintosh HD/Applications/Utilities/Avid Storage Manager, and then double-click the Storage Manager icon.

Exit button

To close Storage Manager: t Click the Exit button in the top toolbar, or select File > Exit. n If ASM does not start on a Windows system, ensure that JAVA is installed. An installation is available inn the same file folder as ASM on the Storage Utilities CD or at “Java Runtime Environment” at http://www.java.sun.com.

start starts starting stop stops stopping exit exits exiting

Setting User Preferences

You can set user preferences that determine the default behavior of Storage Manager as follows: • The initial view for the main window (Physical view or Volume view) • The default window’s location, size, and “look and feel” • The default e-mail addresses for sending and receiving log and configuration files

User Preferences button

To set user preferences: 1. Click the User Preferences button in the top toolbar, or select Edit > User Preferences. 2. Click the tab for the preferences you want to set: - Window User Preferences - View User Preferences - E-mail User Preferences 3. Make your changes, and then click Apply. 4. Repeat steps 2 and 3 to set the options on the other tabs. 5. When you have finished setting user preferences, click OK to close the User Preferences dialog box.

32 Setting User Preferences

6. Close Storage Manager, and then reopen it to make your new user preferences active.

preference preferences e-mail e-mails

Window User Preferences

The following table describes the Window user preferences.

Window User Preferences

Option Type Option Description

Default Location Top, Left of Display The Storage Manager window opens (Default) in the upper left corner of your display.

Centered in Display The Storage Manager window opens in the center of your display.

Current Position The Storage Manager window opens in the same location where it was last closed.

Default Size Optimized for The Storage Manager window is Display (Default) sized as large as possible, up to 800 x 600 pixels.

Maximized in The Storage Manager window is Display sized to fill the entire display.

Current Size The Storage Manager window opens with the same dimensions as when it was last closed.

preference preferences

View User Preferences

The following table describes the View user preferences.

33 Chapter 3 Using Storage Manager

View User Preferences

Option Type Option Description

Default Window Physical View When it opens, Storage Manager Window (default) displays Physical view.

Volume View When it opens, Storage Manager Window displays Volume view.

Main Window Only When it opens, Storage Manager displays the main window with neither Physical view nor Volume view showing.

Default Look & CDE/Motif Storage Manager uses CDE Feel (Windows and Macintosh) or Motif style windows (Macintosh only).

MacOS Adaptive Storage Manager uses Mac OS X style windows (Macintosh only).

Metal Storage Manager uses Metal style windows.

Windows Storage Manager uses Windows style windows (Windows only).

preference preferences

E-mail User Preferences

The following table describes the e-mail user preferences.

E-mail User Preferences

Option Description

Recipient E-mail The default e-mail addresses for the recipients of log and Addresses configuration files.

Sender E-mail The default e-mail address for the sender of log and Address configuration files.

Outgoing Mail The name of the SMTP server used to deliver the (SMTP) Server e-mail. To use this feature, the system running Storage Manager must have a network connection to an SMTP server.

34 Selecting Hard Drives

E-mail User Preferences

Option Description

E-mail Subject The default subject line for the log and the configuration file e-mail messages.

preference preferences e-mail e-mails

Selecting Hard Drives

Selecting the correct hard drives in both Physical view and Volume view is important before you use any of the features in Storage Manager, especially if you are running a destructive test.

In Storage Manager, you can select a single drive or multiple drives: • Selecting a Single Drive • Selecting Multiple Drives c Running a destructive test destroys the data on a hard drive. Do not run a destructive test on your internal boot drive or on any drive that has data you want to keep.

select selects selecting drive drives choose chooses choosing

Selecting a Single Drive

The procedure for selecting a single drive in Physical view and in Volume view is identical.

To select a single drive in Physical view or Volume view: t Click the check box next to the hard drive description to enable it. If you select a drive that is part of a stripe set, Storage Manager will ask you if you want to select all the drives in the set or just the one you clicked.

Related Topics Selecting Multiple Drives

select selects selecting drive drives choose chooses choosing

Selecting Multiple Drives

The procedures for selecting multiple drives differ slightly in Physical view and in Volume view.

35 Chapter 3 Using Storage Manager

To select multiple hard drives in Physical view: t Click the check box next to the adapter board description to select all of the drives that are connected by that adapter board.

To select multiple hard drives in Volume view: t Click the check box next to the volume name to select all of the drives that make up that volume. n You can also use the Shift and Ctrl keys to select multiple drives. Related Topics Selecting a Single Drive Physical View Vo lu me View

select selects selecting drive drives choose chooses choosing

Viewing Hard Drive Information

Storage Manager has two features for viewing hard drive information. One feature provides details on the physical hardware for a drive. The other feature provides information on the volumes that use all or a portion of the hard drive’s storage space. • Viewing Hardware Information • Viewing Volume Information

hardware drive drives information volume

Viewing Hardware Information

Use the following procedure to access the dialog boxes in Physical View:

To view the hardware information for hard drives: 1. In Physical view, click the check boxes for the hard drives for which you want information. If you select a drive that is part of a stripe set, Storage Manager asks you if you want to select all drives in the set or just the drive you selected. 2. Right-click (Windows) or Control+click (Macintosh) a selected hard drive description, and select Device Information. The Device Information dialog box for the controller opens as well as a dialog box for each drive connected to that controller, one on top of the other (see the following figure).

36 Viewing Hard Drive Information n To view the Device Information dialog boxes that are hidden, click OK to close the topmost dialog box, or click the topmost dialog box and drag it away from the dialog box behind it.

3. Click OK to close the Device Information dialog box Detailed descriptions of the information contained in the Device Information dialog box follows.

Physical View - SCSI Drives

Check boxes

Controller dialog box

Individual drive dialog box

37 Chapter 3 Using Storage Manager

Physical View - RAID Drives

Check box

Controller dialog box

Individual drive dialog box

In Physical View, dialog boxes display the following information for controllers and drives. The following tables define the labels on the dialog boxes.

38 Viewing Hard Drive Information

Controller Dialog Box (Device Information)

Label Description

Device A description of the selected hard drive. This information includes the drive type, its bus ID, its device ID, and its LUN ID. For example, HDD 1:1:0 indicates a hard drive on bus 1 with a device ID of 1 and a LUN ID of 0. n Bus numbers for SCSI drives start at 0. Bus numbers for FireWire drives start at 64.

Vendor The manufacturer of the hard drive.

Model The model number of the hard drive.

Status The status of the hard drive. Possible values are: • Ready: The drive is available and ready for testing. • Not Ready: The drive is not ready for testing

Firmware Revision The firmware revision of the hard drive.

Alerts Alerts can be either reallocated sectors (also known as G- list) or time outs on a RAID drive. Reallocated sectors are the number of times the drive might have mapped out the unusable sectors on that drive. All drives have an allowable number of unusable sectors that do not impact performance. RAID drives may have different reporting methods and may refer to these issues as time-outs. These time-outs may be due to the instantaneous heavy usage or due to a pending problem with a drive. Each drive has a specific alert threshold and replacement of the drive depends on the type of drive how it is connected to your system. Please contact your Avid Customer Support for further information.

39 Chapter 3 Using Storage Manager

Drive Dialog Box (Device Information)

Label Description

Device A description of the selected hard drive. This information includes the drive type, its bus ID, its device ID, and its LUN ID. For example, HDD 1:1:0 indicates a hard drive on bus 1 with a device ID of 1 and a LUN ID of 0. n Bus numbers for SCSI drives start at 0. Bus numbers for FireWire drives start at 64.

Format The type of partition that currently exists on the hard drive. For complete information, see “Partition Status Indicators” on page 22.

Vendor The manufacturer of the hard drive.

Model Number The model number of the hard drive.

Serial Number The serial number of the hard drive.

Capacity The storage capacity of the hard drive. The first number is based on the industry standard—1024 bytes equals one kilobyte (KB) — and the second number is the actual physical byte count on the drive.

Firmware Revision Firmware revision notation

Alerts Alerts can be either reallocated sectors (also known as G- list) or time outs on a RAID drive. Reallocated sectors are the number of times the drive might have mapped out the unusable sectors on that drive. All drives have an allowable number of unusable sectors that do not impact performance. RAID drives may have different reporting methods and may refer to these issues as time-outs. These time-outs may be due to the instantaneous heavy usage or due to a pending problem with a drive. Each drive has a specific alert threshold and replacement of the drive depends on the type of drive how it is connected to your system. Please contact your Avid Customer Support for further information.

Related Topics Viewing Volume Information

40 Viewing Hard Drive Information

hardware drive drives information device devices servo firmware revision manufacturing date testing availability status capacity series serial number vendor model format raw ATTO Unity Mac PC Remus ready unavailable testing passed failed

Viewing Volume Information

To view the volume information for hard drives: 1. In either Physical view or Volume view, click the check boxes for the hard drives on which you want information. 2. Right-click (Windows) or Control+click (Macintosh) a selected hard drive description, and select Device Information. The Device Information dialog box opens. If you have selected multiple hard drives, then several dialog boxes open, one on top of the other.

Check boxes

Volume dialog box

3. Click OK to close the Device Volumes dialog box.

In Volume View, dialog boxes display the following information for drives:

Volume Drive Dialog Box

Category Description

Volume The name of any volumes that use all or a portion of the hard drive’s storage capacity.

Format Partition type. For complete information, see “Partition Status Indicators” on page 22.

41 Chapter 3 Using Storage Manager

Volume Drive Dialog Box

Category Description

Capacity The storage capacity of the partition. The first number is based on the industry standard—1024 bytes equals one kilobyte (KB) — and the second number is the actual physical byte count.

Status Mounted, Unmounted, or Broken.

Related Topics Viewing Hardware Information

volume volumes drive drives information bus LUN device devices mount mounts mounting status capacity mounted unmounted broken striped unstriped

Identifying Hard Drives

The Identify button in the side toolbar provides a visual aid that allows you to match the hard drive descriptions in the main window with the physical hard drives in your storage subsystem.

Identify button

To identify hard drives: 1. In either Physical view or Volume view, click the check boxes for the hard drives you want to identify. 2. Click the Identify button in the side toolbar. The Identify Device dialog box opens, and the drive activity LEDs for the drives you selected start to blink. n The drive activity LEDs blink for approximately 1 second on and 1 second off. 3. Click OK to close the Identify Device dialog box and stop the blinking LEDs.

drive drives identify identifying LED LEDs

42 Spinning Down Hard Drives Spinning Down Hard Drives

You can use Storage Manager to spin down your Avid shuttles. The Spin Down feature parks the drive heads, stops the drive from rotating, and ensures that you can safely swap the drive without loss of data or damage to the drive.

You should use the Identify feature to identify drives before spinning them down (see “Identifying Hard Drives” on page 42). Only removable drives that you plan to remove should be spun down. If you spin down a fixed drive or an internal system drive, you must turn it off and then turn it on for the drive to spin up again. n The Spin Down feature is only supported for SCSI and Fiber Channel drives.

Spin Down button

To spin down hard drives: 1. Make sure the hard drives you want to spin down do not have any volumes that are mounted. If they do, then unmount the volumes before spinning down the drives. 2. In Physical view or Volume view, click the check boxes for the hard drives you want to spin down. 3. Click the Spin Down button in the side toolbar. 4. The hourglass pointer appears, and Storage Manager waits 30 seconds to ensure that all of the drives are spun down. When the hourglass pointer disappears, the spin down is complete. n For information about spinning up a shuttle, see your shuttle enclosure documentation. In most cases, the shuttle spins up when you insert it in the shuttle enclosure. If you inadvertently spin down a fixed drive, you must turn the drive power switch off and then on to spin the drive back up for use.

drive drives spin spins spinning down IDE SCSI heads hot-swap hot-swapping

Rescanning the Storage Subsystem

Rescan button

You can manually initiate the Rescan feature by clicking the Rescan System Configuration button in the top toolbar, or by selecting Edit > Rescan Configuration.

43 Chapter 3 Using Storage Manager

When the Rescan feature is active, Storage Manager scans all of the hard drives in your storage subsystem and updates the information in the main window. n Hard drives with an availability/testing status of Passed, Failed, or Updated change their status back to Ready when you rescan the storage subsystem.

Partition status that changed since you started ASM will not be reflected unless you rescan the system.

Rescanning might not find hard drives or shuttles that you added to the Avid system since the last system boot. If you have added hard drives since the last system boot, you might need to restart your system.

To rescan for new drives: t (Windows) Run Disk Manager to rescan the buses, and then click the Rescan System Configuration button to locate the new hard drives. If the new hard drives still do not appear, then reboot the system. t (Macintosh) Restart the Macintosh system and run Storage Manager to locate the new hard drives.

drive drives storage subsystem scan scans scanning refresh refreshes refreshing physical volume view

Saving the Storage Subsystem Configuration

In Storage Manager, you can save your storage subsystem’s configuration to a log file. Avid Customer Support uses the information in this file for diagnostic purposes.

Save Configuration button

To save the storage subsystem configuration: 1. Click the Save Configuration button in the top toolbar, or select File > Save Configuration. 2. Click the Browse button, and then navigate to the location where you want to save the configuration file. 3. Type a name for the file. The default file name is: ASMConfig-MM.DD.YY.txt where MM is the month, DD is the day, and YY is the year the file was created. 4. Click OK, and then click OK again to close the Save Configuration dialog box and save the file. 44 Sending Error Log and Configuration Files

Related Topics Sending Error Log and Configuration Files

save saves saving configuration configurations storage subsystem

Sending Error Log and Configuration Files

You can send error logs and configuration files directly from Storage Manager to other locations through e-mail. You can use this feature to send error and configuration information to Avid Customer Support for a diagnosis of storage-related problems. c Before using the e-mail feature, make sure the computer running Storage Manager has a network connection to an SMTP server. n Error logs are generated while testing your hard drives. For more information, see Testing Hard Drives.

Send File button

To send a log file: 1. Click the Send File button in the top toolbar, or select File > Send File. The dialog box is partially filled in with information from the e-mail preferences you set (see Setting User Preferences). You can accept this information, or you can override it by typing new information in the text boxes. 2. Click the Browse button to locate the error log or configuration file you want to send. 3. Select the file you want to send, and then click OK to close the Select File dialog box. n You can type the file name in the File text box. If the file does not exist in the directory where Storage Manager is installed — by default, C:\Program Files\Avid\Utilities\Avid Storage Manager (Windows) or Macintosh HD/Applications/Utilities/Avid Storage Manager (Macintosh) — you must type the entire path.

4. Click OK to send the file and to close the Send File dialog box.

Related Topics Saving the Storage Subsystem Configuration

45 Chapter 3 Using Storage Manager

Testing Hard Drives

send sends sending e-mail e-mails e-mailing log error configuration

Updating Hard Drive Firmware c Do not perform this procedure unless directed to do so by Avid Customer Support. You can use Storage Manager to update the firmware on your Avid hard drives. When you use this feature, all hard drives that are acceptable candidates for the updated firmware package are updated automatically. You cannot select specific hard drives for updating. A drive is an acceptable candidate for updating if it is the correct type of drive for the updated firmware, and its current version of firmware is earlier than the version of the updated firmware.

For more information, see: • Obtaining an Updated Firmware Package • Updating Hard Drives

firmware drive drives update updates updating

Obtaining an Updated Firmware Package

Updated firmware packages are distributed through the following: • Avid Knowledge Base • Storage Utilities CD-ROM c Always close Storage Manager before retrieving firmware updates. To retrieve an updated firmware package from the Avid Knowledge Base: 1. Go to www.avid.com. 2. Click the Support tab, and then select Online Support. 3. Under the Knowledge Center heading, click Downloads. The Knowledge Center opens in the Downloads tab. 4. Locate the firmware update, and then download the file to the following location: (Windows) C:\Program Files\Avid\Utilities\Avid Storage Manager\FirmwarePackages (Macintosh) Macintosh HD/Applications/Utilities/Avid Storage Manager/FirmwarePackages

46 Updating Hard Drive Firmware

n You can use the Search feature to find the update. You can also click Storage Utilities Table at the top of the Downloads tab and select the update from the Storage Utilities Download table. n If you installed Storage Manager in a directory other than the default, download the firmware update to the FirmwarePackages directory in that location instead. n If you do not have a FirmwarePackages folder, you must create one and copy the firmware package files into the folder.

5. Uncompress the update file.

To retrieve an updated firmware package from the Storage Utilities CD-ROM: 1. Insert the Storage Utilities CD-ROM into the CD-ROM drive. 2. Navigate to the Storage Manager directory on the Storage Utilities CD-ROM. 3. Copy the firmware update package from the Storage Manager directory to the following location: (Windows) C:\Program Files\Avid\Utilities\Avid Storage Manager\FirmwarePackages (Macintosh) Macintosh HD/Applications/Utilities/Avid Storage Manager/FirmwarePackages n If you installed Storage Manager in a directory other than the default, copy the firmware update to the FirmwarePackages directory in that location instead. n If you do not have a FirmwarePackages folder, you must create one and copy the firmware package files into the folder.

Related Topics Updating Hard Drives

firmware drive drives update updates updating obtain obtains obtaining

Updating Hard Drives

After downloading the firmware update package, you are ready to update your Avid hard drive or MediaRAID enclosure.

Update Firmware button

47 Chapter 3 Using Storage Manager

To update the firmware for your Avid hard drive:

1. Open Storage Manager. 2. Click the Update Firmware button in the top toolbar, or select Edit > Update Firmware. Storage Manager checks for drives and enclosures that require updating, prints the list in the Console window, and checks for available firmware update files. A dialog box opens, informing you of the number of drives and enclosures to be updated and asking if you want to continue. 3. Click Yes to continue. Storage Manager updates any Avid hard drives that are the correct type for the firmware update and that currently have an earlier version of firmware. The Console window displays the progress of the update for each drive and enclosure. c Do not close Storage Manager or turn off hard drives when performing a firmware update. Doing so might cause the drives to become inoperable, requiring them to be returned to Avid for replacement at the discretion of Avid Customer Support.

Related TopicsWhen the update is complete, an Updated label displays next to all updated drives listed in the Physical View Window Obtaining an Updated Firmware Package

firmware drive drives update updates updating obtain obtains obtaining

48 Chapter 4 Tuning Digidesign Drives

This section has detailed information on tuning Digidesign DigiDrive drives for optimal performance. The Storage Manager Drive Tuner feature provides the ability to set the mode pages on DigiDrive drives for use with Pro Tools, AVoption, and AVoption|XL systems. n Drive Tuner is supported on DigiDrive SCSI drives only. You cannot tune DigiDrive FireWire drives.

This section includes the following topics: • Pro Tools System Prerequisites (Windows) • Pro Tools System Prerequisites (Macintosh) • Using the Storage Manager Drive Tuner

Before you use Drive Tuner to optimize your DigiDrive drives, first check the following to make sure your system is ready: • The DigiDrive drives are connected to the SCSI host bus adapter board. • The Pro Tools, AVoption, or AVoption|XL system is turned on. • The DigiDrive drives are turned on. • If you are using a Macintosh system, the DigiDrive drives are visible on the desktop. • If you are using a Windows system, the DigiDrive drives are visible in the My Computer window or in Windows Explorer. n If the DigiDrive drives are not visible, see the Troubleshooting section of the DigiDrive Guide included on the DigiDrive CD-ROM. Chapter 4 Tuning Digidesign Drives Pro Tools System Prerequisites (Windows)

Before you use the Storage Manager Drive Tuner on your DigiDrive drives in a Windows system, format your DigiDrive drives with the Windows Disk Administrator or the Windows Disk Management utility. For more information, see the DigiDrive Guide that came with your DigiDrive drives.

Pro Tools System Prerequisites (Macintosh)

Before you use the Storage Manager Drive Tuner on your DigiDrive drives in a Macintosh system, initialize your drives with the ATTO ExpressStripe utility (included with Pro Tools TDM Macintosh systems). n Do not use the Digital Audio mode page settings in the ATTO ExpressStripe utility. Storage Manager Drive Tuner sets the optimal mode pages for Pro Tools systems.

Using the Storage Manager Drive Tuner

You need to run the Storage Manager Drive Tuner once when your Pro Tools system is first set up, and then each time you add a new DigiDrive drive to the system.

Tune button

To use the Storage Manager Drive Tuner: 1. Open Storage Manager. The Storage Manager main window opens showing all of the attached storage devices. 2. Click the Tune button in the side toolbar. Storage Manager searches your Pro Tools system for DigiDrive drives, and then sets the drive mode pages.

When Drive Tuner is finished, the message appears, “Mode page check complete. X devices checked, Y tuned,” where X is the number of DigiDrive drives mounted on the system and Y is the number of drives tuned.

50 Chapter 5 Testing Hard Drives

This section provides detailed information on the tests you can perform on your Avid hard drives and DigiDrive drives with Storage Manager.

This section includes the following topics: • Nondestructive and Destructive Tests • Testing Your Hard Drives • Test Templates • Test Parameters • Error Messages

Nondestructive and Destructive Tests

There are two types of tests you can perform with Storage Manager: nondestructive and destructive. • Nondestructive tests only read the data on the hard drive. They do not write any data to the hard drive. • Destructive tests write data to the drive and then read that data. The tests then compare the written data to the original data to verify that the write and read functions of the hard drive are working correctly. These tests destroy any data and the file system structure that are on the drive. c Running a destructive test destroys all the data on a hard drive. Do not run a destructive test on your internal boot drive or on any drive that has data you want to keep. Chapter 5 Testing Hard Drives

n Destructive tests do not remove data stored on hard drives sufficiently for a full security erase.

Related Topics Test Templates Test Parameters

test tests testing destructive nondestructive

Testing Your Hard Drives

To perform a test you must: 1. Set up the test either by using one of Avid’s test templates or by specifying the test parameters yourself. 2. Run the test. 3. Review the test results.

Click one of the following links for more details on these tasks: • Using a Test Template • Creating a Custom Test • Running a Test • Viewing Test Information

Related Topics Test Templates Test Parameters

test tests testing introduction overview

Using a Test Template

Avid has created four test templates to aid you in testing your hard drives. Each template has its own test parameters that are set automatically. For detailed descriptions of the templates, see Test Templates.

Test button

52 Testing Your Hard Drives

To use a test template: 1. Select one or more drives to test.

Click the Test button in the side

toolbar.

2. Click the Template pop-up menu, and select a test template. The test parameters in the remainder of the Test window are set according to the template you selected. 3. To run the test using the template parameters, follow the instructions in Running a Test.

Related Topics Creating a Custom Test Test Parameters

test tests testing template templates

Creating a Custom Test

You can create a custom test by modifying an existing template to fit your needs.

Test button

53 Chapter 5 Testing Hard Drives

To create a custom test: 1. Select one or more drives to test. 2. Click the Test button in the side toolbar. 3. Click the Template pop-up menu, and select a test template. 4. Change any test parameters in the remainder of the Test window. The Template pop-up menu automatically changes to User Selected to indicate that you have customized the template. 5. To run the test using the custom parameters, follow the instructions in Running a Test.

Related Topics Using a Test Template Test Templates Test Parameters

test tests testing custom template templates

Running a Test

Once you have set the test parameters by using an existing template or by creating a custom test, you are ready to run the test. c Running a destructive test destroys all data on a hard drive. Do not run a destructive test on your internal boot drive or on any drive that has data you want to keep. Use the Identify feature to verify that you are testing the correct drive (see “Identifying Hard Drives” on page 42).

If you run a test from a client in a LANshare environment, test coverage is limited as follows: • SCSI or Fibre Channel drives do not allow for soft error reporting and data reallocation. • IDE drive serial numbers are not available. • Reallocated block count is not available.

To run a test: 1. After setting the test parameters, click the Start button in the Test window. If you select a destructive test, a message box opens, warning you that the test will permanently delete data on your drive. Click Yes to continue. The test starts running, and the Status indicator at the bottom of the Test window begins tracking the test. This indicator tracks each pass of the test, not the test as a whole.

54 Testing Your Hard Drives

2. Use the following options to control the test while it is running: - To pause the test, click the Pause button (the button label then changes to Resume). Click the Resume button to restart the test at the point it paused. Storage Manager retains the present state of the test and all test parameters during a pause. - To stop the test, click the Stop button. The test parameters are saved for a future restart, but all other testing information (elapsed time, error counts, and so forth) are reset. - To view the test results as the test is being run, click the Console button. The Console window opens. For more information on the Console window, see Viewing Test Information.

Related Topics Using a Test Template Creating a Custom Test Test Templates Test Parameters

test tests testing run runs running start stop pause resume console

Viewing Test Information

You can view test information in two ways: by using the Console window or by looking at the error log file (if you opted to create one during the test). t To view test status while the test is running, use the Console window. t To view test status after the test has finished, look at the error log file.

Test status information includes: • A list of all the drives connected to the Avid system, including the drive type, bus ID, device ID, and LUN ID • The type of test being run • The set of test parameters used to perform the test • A list of the drives being tested • The status of each drive that is being tested • Error messages • The total number of blocks transferred for each drive (read and write blocks)

55 Chapter 5 Testing Hard Drives

You can also view a summary of the test while it is running, while it is paused, or after it has finished. A test summary has a line for each drive under test and a line for each pass of the test. Test summaries include: • The drive’s bus ID, device ID, and LUN ID • The test pass number • The number of read commands • The number of sectors read • The number of write commands • The number of sectors written • The number of errors • The number of reallocated blocks • The maximum, minimum, and average times for the read and write commands, in milliseconds • The total number of I/Os per second for the entire storage subsystem n A test’s status information is always followed by a summary at the end of the test in both the Console window and in the log file.

Console button

To view test information using the Console window: 1. Open the Console window using one of the following methods:

t In the Test window, click the Console button. t Click the Console button in the top toolbar. t Select View > Console. 2. To view a summary of the test, click the Summary button. 3. When you are finished looking at the information in the Console window, click the Close button.

To view test information in a log file: t (Windows) The log file is an ASCII text file. Open the file in Notepad. If it is too large for Notepad, open the file in WordPad. t (Macintosh) The log file is an ASCII text file. Open the file in TextEdit. If it is too large for TextEdit, open the file in a word processing application.

56 Testing Your Hard Drives n You can also send your log files to a recipient that you specify. For more information, see Sending Error Log and Configuration Files.

Related Topics Using a Test Template Creating a Custom Test Test Templates Test Parameters

test tests testing view views viewing summary send e-mail console

57 Chapter 5 Testing Hard Drives Test Templates

The following table describes Storage Manager’s test templates. Each template uses a specific set of test parameters that are described in Test Parameters.

Test Templates

Test Description

Extended Test This test provides an overall check of Test Type: (nondestructive) the storage subsystem. It Sequential Read/Random Read nondestructively reads random blocks Log File: on the disk. Each pass reads the entire Keep Log surface and then runs a random read test for approximately 60 minutes. You Name: set the number of passes and the test ASMLog-MM.DD.YY.txt length for the random read test, in Error Halt: minutes. None Test Data Pattern: Random Test Length: Full Surface + 60 Minutes Number of Passes: 1 n All other options are disabled. Quick Check This test provides a quick indication of Test Type: (nondestructive) any serious problems in the storage Random Read subsystem. It nondestructively reads Log File: random blocks on each drive, and it Keep Log runs for 30 minutes. Name: ASMLog-MM.DD.YY.txt Error Halt: None Test Length: 30 Minutes Number of Passes: 1 n All other options are disabled.

58 Test Templates

Test Templates (Continued)

Test Description

Surface Scan This test reads the entire surface area Test Type: (nondestructive) of a selected Avid drive. You run it Surface Scan SCSI 8 Fiber primarily to detect media errors on Log File: Channel ONLY) selected drives. Keep Log When you use this test, you are Name: prompted to choose whether or not to ASMLog-MM.DD.YY.txt automatically reallocate any blocks that have media errors. Reallocating Error Halt: bad blocks scrubs the disk surface None clean of media defects. Number of Passes: If you choose to reallocate bad blocks, 1 Storage Manager reallocates a bad All other options are disabled. block’s address to a good block and, if n possible, copies the data from the bad block to the good block. If the original block contains unreadable data, the block is considered damaged and Storage Manager marks it as bad. Writing data to the reallocated block erases Storage Manager’s bad mark and writes good data into the reallocated block.

Verify This test sequentially reads the entire Test Type: (nondestructive) surface area of a selected Avid drive. Verify The test verifies errors on the drive, but Log File: it does not reallocate data for hard Keep Log (nonrecoverable) media error bad blocks. The test does reallocate data Name: for soft (recoverable) media error bad ASMLog-MM.DD.YY.txt blocks. Error Halt: This test usually is faster than a None Surface Scan because it does not Test Length: transfer data to memory. Full Surface n This test is not available for Number of Passes: IDE or FireWire drives. 1

User Selected This test is automatically selected User Selected, by its definition, indicates that when you modify a test template. you have set your own custom parameters.

59 Chapter 5 Testing Hard Drives

Related Topics Nondestructive and Destructive Tests Testing Your Hard Drives Using a Test Template Creating a Custom Test Running a Test Viewing Test Information

Test Parameters

The following table describes the test parameters you see in the Test window. The first parameter, Test Type, is divided into nondestructive and destructive tests.

60 Test Parameters

Parameter Options

Test Type Random Read (default): This test picks a random starting point on the drive and (nondestructive) a random number of sectors to test. It then reads the drive’s data, beginning at the random starting point and ending after the random number of sectors are read. Convergence/Divergence Read: This test picks a random number of sectors to test. It then reads that number of sectors at the beginning of the drive. After the beginning of the drive is read, the test goes to the end of the drive and reads the same random number of sectors. The test then returns to where it left off at the beginning of the drive, picks a new random number of sectors, and repeats the same process. The test continues until it reads the entire drive twice. The Convergence/Divergence test is useful for identifying problems with the drive heads or with the drive’s servo system.

This read starts at the Beginning End of beginning of the drive. of Drive Drive

This read starts at the end of the drive.

Sequential Read: This test reads the data on the drive from the beginning sector to the last sector. Sequential Read/Random Read: This test starts by reading the data on the drive from the beginning sector to the last sector. It then picks a random starting point on the drive and a random number of drive sectors to test. The test reads the data beginning at the random starting point and ending after the random number of sectors are read. This random read is repeated for the specified test length. Verify: This test reads data on the drive from the beginning sector to the last sector. This test identifies errors, but it does not transfer data to memory or reallocate blocks that have errors.

61 Chapter 5 Testing Hard Drives

(Continued)

Parameter Options

Test Type (destructive) Random Write/Read: This test picks a random starting point on the drive and a random number of drive sectors to test. It then writes data to the drive, reads the data back, and compares it to the original data. Writes and reads are done in pairs; that is, the test writes to a group of sectors, reads the data back, writes to another group of sectors, reads the data back, and so on until the test is completed. Sequential Write/Read: This test writes data from the beginning of the drive to the end of the drive, reads that data back from beginning to end, and compares it to the original data. Sequential Write/Random Read: This test writes data from the beginning of the drive to the end of the drive. It then picks a random starting point on the drive and a random number of drive sectors to test. The test reads the data beginning at the random starting point and ending after the random number of sectors are read. This random read is repeated for the specified test length. Surface Scan: This test scans the entire surface area of the drive. It is run primarily to detect media errors. When you select this test, you are prompted to choose whether or not to automatically reallocate any blocks that have media errors, effectively scrubbing the disk surface clean of media defects. If you choose to reallocate blocks, this test will become destructive if any media errors are found and reallocated. If not, the test is nondestructive. Format Test: This test performs a low-level format on the drive. You should use this test only when directed to do so by Avid Customer Support. If you stop this test before it is completed, the drive might be rendered inoperable, requiring the drive to be returned to Avid for replacement. This test cannot be used with IDE or FireWire drives. Random Write: This test picks a random starting point on the drive and a random number of drive sectors. It then writes data between those two points. This test is useful for diagnostics. Sequential Write: This test writes data from the beginning of the drive to the end of the drive. This test is useful for diagnostics.

Log File Keep Log: Select this option to keep a log file for the tests you are running. Error logs are cumulative on a daily basis. An error log is appended with information from each test you run during a single day (as indicated by the computer’s internal date at the start of the test). When the date changes, a new error log is started. However, if a test runs over the course of several days, only one log file is generated for the entire test. No Log: No error log is generated while your tests are run. n For more information on the naming conventions for error log files, see the Name parameter.

62 Test Parameters

(Continued)

Parameter Options

Name When you select the Keep Log option, the Name text box is enabled. This box contains the name of the log file to be generated during testing. By default, this file name has the following format: ASMErrorLog-MM-DD-YY.txt You can overwrite the default file name with a name you specify by typing it in the Name text box. You must type the entire path if you are saving the file to a directory other than the default directory. You can also use the Browse button to specify a file name and a location for the log file. n On Macintosh systems, the file name is preceded by the following path notation: ../../../../. This saves the file in a location separate from the Storage Manager utility.

63 Chapter 5 Testing Hard Drives

(Continued)

Parameter Options

Error Halt None (default): The test continues even when it encounters an error, except when it encounters a catastrophic error. Catastrophic errors stop the test because they are not likely to be corrected and they fill the error log with redundant error information. Any Error: The test stops when any drive encounters an error, regardless of the error type. Media Error: The test stops when any drive encounters a nonrecoverable media error. A media error is an error in the magnetic drive media, for example, a bad sector on the drive. Nonrecoverable Error: The test stops when any drive encounters a nonrecoverable error. Nonrecoverable errors include the following: • A unit attention result that is not the result of a drive power-up or a SCSI Reset command • An illegal request error • An aborted command error • Most driver errors Catastrophic Error: The test stops when it encounters a catastrophic error. Catastrophic errors include the following: • A drive seems to have “disappeared” or is nonexistent • A drive not ready error • A hardware error • A data protection error • Any error not recognized by Storage Manager User Defined: The test stops when an error count that you specified is reached. The error count applies to any error type.

Errors If you select User Defined as your Error Halt parameter option, type the number of errors required before the test stops in the Errors text box. The number you type must be greater than 5, representing the maximum number of errors for each drive in the test.

Data Compare Mode Compare All Data (default): For write/read tests, the data written to a hard drive and then read back is compared to the original data for discrepancies. No Data Compare: No data comparison is made between the data written to a hard drive during a write/read test and the original data. Compare First Sector: For write/read tests, the first 512 bytes of data written to a hard drive and then read back are compared to the original data for discrepancies.

64 Test Parameters

(Continued)

Parameter Options

Test Data Pattern Random (default): Random data is written to the drive. Alternating: The data written to the drive uses alternating words comprised of all 0s (zeros) or all 1s (ones). Incrementing Byte: The data is written using an incrementing byte pattern where the 00 byte is never used. Skipping the 00 byte ensures that as the data repeats itself, it never falls on sector boundaries. This prevents the repetition of the pattern from masking possible data corruption problems. Incrementing Word: The data is written using an incrementing word pattern. User Defined: This option allows you to specify a number greater than 5 to be used as the repeating pattern.

Pattern If you select User Defined as your Test Data Pattern parameter option, type a number greater than 5 in the Pattern text box.

Test Length 30 Minutes (default): The test runs for 30 minutes and then stops. 60 Minutes: The test runs for 60 minutes and then stops. 120 Minutes: The test runs for 120 minutes and then stops. User Defined: The test runs for the amount of time you specify in the Minutes text box. It is applicable to random tests only.

Minutes If you select User Defined as your Test Length parameter option, type the number of minutes that the test is to run before it stops in the Minutes text box.

Number of Passes 1 (default): The test runs once and then stops. Infinite: The test runs until you manually stop it by clicking the Stop button in the Test window. User Defined: The test runs for the number of passes specified in the Passes text box. A pass is completed for a sequential test either when the whole drive has been tested or when the time period for the test ends.

Passes If you select User Defined as your Number of Passes parameter option, type the number of passes required before the test stops in the Passes text box.

Related Topics Nondestructive and Destructive Tests Testing Your Hard Drives Using a Test Template Creating a Custom Test

65 Chapter 5 Testing Hard Drives

Running a Test Viewing Test Information Test Templates

Error Messages

The error messages in the Console window or in the error log files give you valuable information about the state of your hard drives. For descriptions of the most common errors and how to correct them, see Interpreting Error Messages.

66 Appendix A Interpreting Error Messages

This section provides information on the error messages you might see in the Console window and the steps you can take to fix the errors. For a full description of these messages, see Error Messages and Corrective Actions.

Error Messages and Corrective Actions

The following table describes the most common error messages that might be generated while you test Avid hard drives, and includes actions you can take to diagnose and fix problems. n Error messages include “sense keys” in the Storage Manager Console window. n Some sense keys provide additional information about the error.

Error Messages

Error Message Description Comment or Action

00 NO SENSE The operation completed None required. successfully with no errors.

01 RECOVERED ERROR The operation completed Recovered errors usually are not a major successfully with some recovery concern. Run the Surface Scan test, and action performed by the drive. rerun the test that had the errors. Appendix A Interpreting Error Messages

Error Messages (Continued)

Error Message Description Comment or Action

02 NOT READY The drive cannot be accessed. Wait 2 minutes, and rerun the test. If the User intervention might be error reoccurs, turn the drive’s power off and required to correct this condition. then on, wait 2 minutes, and rerun the test. If the error persists, replace the drive.

03 MEDIUM ERROR A 03 - 11 error indicates that the Run the Surface Scan test, enabling block test terminated with an reassignments, and rerun the test that failed. unrecoverable error probably caused by a flaw in the media or an error in the recorded data.

A 03 - 31 error indicates a format Run the Format test, and do not interrupt or corruption problem. This might turn off the hard drive or the Avid system occur after a firmware download. until the reformatting is complete. It might also occur if a low-level drive format was started and not completed.

04 HARDWARE ERROR The hard drive detected an Turn the drive’s power off and then on, and unrecoverable hardware failure rerun the test. If the error reoccurs, replace while performing the test or the drive. during a self-test.

05 ILLEGAL REQUEST There was an illegal parameter in This is a software error, not a hardware the test. error, and it should not be seen unless the software contains a bug.

06 UNIT ATTENTION The removable media has been This is a normal occurrence after power changed or the hard drive has cycling the drive or after rebooting your been reset or power cycled. Avid system. This error might be reported at the beginning of a test. If the error is reported after the start of a test, check the drive’s cabling, termination, and adapter board. If the error continues, turn off the first drive and rerun the test. If the error persists, turn on the first drive and turn off another drive, and rerun the test. Continue to cycle through the drives until the error is no longer reported. The drive that is turned off at this point needs to be replaced.

68 Error Messages and Corrective Actions

Error Messages (Continued)

Error Message Description Comment or Action

0B ABORTED The hard drive aborted the test. This usually indicates a bus problem caused COMMAND by a cable, a terminator, or an adapter board seating problem. Tighten all cable and terminator connectors. Reseat the adapter board and rerun the test. Most importantly, check all connectors for bent pins. If the error persists and the drives are connected with daisy-chained cables (device to device), proceed as follows: 1. Reconfigure the cables to test half the drives, move the terminator to the last drive still connected in the chain, and rerun the test. 2. If the error is no longer reported, add one drive at a time to the daisy chain and rerun the test. 3. If the error reoccurs, replace the last cable that you added and rerun the test. 4. If the error is still reported, remove the last drive you added and continue with the next drive until all the drives have been successfully added to the bus and the errors are no longer reported. 5. Replace either the cable or the drive that failed. n If you reconfigure the cables to use half the drives and the error still occurs, reconfigure the cables to use the other half of the drives and perform steps 1 to 5 again.

There are other errors (especially in ATA/IDE drives) that are not indicated as a standard error, such as a time-out. Those errors are indicated by an unusually high number of Alerts. An unusually high number of Alerts might require a drive replacement. Contact Avid Customer Service.

69 Appendix A Interpreting Error Messages

70 A B C D E F G H I J K L N O P Q R S T U V W X Y Z

Index

A Console window 55, 56, 66 Convergence/Divergence Read test 61 Adapter boards Converters Fibre Channel 17 Physical view 19 Physical view 19 SCSI 17 Availability/testing status 21, 44 D Avid System Test Pro 29 Data Compare Mode parameter 64 AvidStartup 29 Destructive tests 51 Device ID 17 B Device information hard drive 39, 40 Bus ID 16 partition 39, 40 Buttons viewing 37 Close 28 Device volume information 41 Console 27, 56 Devices Exit 27, 32 connecting 17 Help 27, 28 ID 17 Identify 28, 42 Drive Tuner Physical View 27 Macintosh prerequisites 50 Rescan System Configuration 27, 43 using 50 Save Configuration 27, 44 Windows prerequisites 50 Send File 27, 45 Spin Down 28, 43 Test 28, 53, 54 E Tune 50 E-mail Update Firmware 27, 48 log and configuration files 34, 45 User Preferences 27, 32 user preferences 34 Volume View 27 Error Halt parameter 64 Error logs 45, 55, 62, 63, 66 C Error messages ABORTED COMMAND 69 Close button 28 HARDWARE ERROR 68 Configuration ILLEGAL REQUEST 68 saving 44 MEDIUM ERROR 68 sending 45 NO SENSE 67 Console button 27, 56 NOT READY 68 Index A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

RECOVERED ERROR 67 I sense keys 67 UNIT ATTENTION 68 ID (identification number) Errors Bus 16 catastrophic 64 described 16 media 64 Device 17 nonrecoverable 64 LUN 17 user defined 64 Identify button 28, 42 Errors parameter 64 Identifying hard drives 42 Exit button 27, 32 Installing Extended test 58 Macintosh 14 overview 13 Windows 14 F Features K ID 16 overview 15 Keep Log option 62 Fibre Channel adapter board 17 L ID 17 Firmware Log File parameter 62 locating updates 46 Logging updating 46, 47 errors 45, 55 Format test 62, 68 naming log files 63 sending log files 45 storage subsystem configuration 44 H tests 62 Hard drives LUN ID (logical unit number) 17, 19 custom test 53 HDD 19 M identifying 42 LUN 19 Main window optimizing 49 default size 33 Physical view 18 overview 18 RAID controller 19 Physical view 18, 18 raw 22 toolbars 26 Raw drives list 24 user preferences 33 selecting 35, 35, 35 Volume view 18, 24 spinning down 43 Minutes parameter 65 stripe drives 25, 26 Mount status indicator 25 testing 51, 52, 54 tuning 49, 50 N updating firmware 47 viewing information 36 Name parameter 63 Hardware information 36 No Log option 62 HDD (hard disk drive) 19 Nondestructive tests 51 Help button 27, 28 Number of Passes parameter 65

72 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Index

P Send File button 27, 45 Sense keys 67 Partition status indicator 22 Sequential Read test 61 Partitions 22 Sequential Read/Random Read test 61 Passes parameter 65 Sequential Write test 62 Pattern parameter 65 Sequential Write/Random Read test 62 Physical view Sequential Write/Read test 62 adapter board 19 Side toolbar availability/testing status 21 Close button 28 converter 19 Help button 28 described 18 Identify button 28, 42 hard drive 18 Spin Down button 28, 43 hardware information 36 Test button 28, 52, 53 partition status indicator 22 Tune button 50 RAID controller 19 Spin Down button 28, 43 selecting a single hard drive 35 Spinning down hard drives 43 selecting multiple hard drives 35 Storage configuration unit indicator 21 log files 44 volume information 41 saving 44 Physical View button 27 Stripe drives 25, 26 Preferences Subsystem configuration 44 See User preferences Surface Scan test 59, 62, 67, 68

Q T Quick Check test 58 Templates See Test templates R Test button 28, 52, 53 Test Data Pattern parameter 65 RAID controllers Test Length parameter 65 Physical view 19 Test parameters RAID enclosures Data Compare Mode 64 updating firmware 47 Error Halt 64 Volume view 26 Errors 64 Random Read test 61 Log File 62 Random Write test 62 Minutes 65 Random Write/Read test 62 Name 63 Raw drives 22, 24 Number of Passes 65 Rescan System Configuration button 27, 43 Passes 65 Rescanning 43 Pattern 65 Test Data Pattern 65 S Test Length 65 Test Type (destructive) 62 Save Configuration button 27, 44 Test Type (nondestructive) 61 SCSI Test templates adapter board 17 Extended 58 ID 17 Quick Check 58

73 Index A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

selecting 52 Send File button 27, 45 Surface Scan 59, 67, 68 Update Firmware button 27, 48 User Selected 59 User Preferences button 27, 32 Verify 59 Volume View button 27 Test Type parameter 61, 62 Tune button 50 Testing Tuning 49, 50 Console window 55 error logs 55, 56 U hard drives 54 LANshare client 54 Unit indicator 21 options 52 Update Firmware button 27, 48 summary 56, 56 User preferences Tests appearance 34 Convergence/Divergence Read 61 CDE/Motif 34 custom test 53 e-mail 34 destructive 51, 54 Main window 33 error logs 62 options 33 Extended 58 User Preferences button 27, 32 Format 62, 68 User Selected test 59 nondestructive 51 Utilities pausing 55 Avid System Test Pro 29 Quick Check 58 AvidStartup 29 Random Read 61 Random Write 62 Random Write/Read 62 V Sequential Read 61 Verify test 59, 61 Sequential Read/Random Read 61 Volume Sequential Write 62 information 41 Sequential Write/Random Read 62 name 25 Sequential Write/Read 62 Volume view stopping 55 description 24 Surface Scan 62 hardware information 36 test templates 52, 52, 58 mount status indicator 25 User Selected 59 RAID enclosure 26 Verify 61 Raw drives list 24 viewing information 55 selecting a single hard drive 35 Toolbars selecting multiple hard drives 35 side toolbar 28 volume information 41 top toolbar 26 volume name 25 Top toolbar Volume View button 27 Console button 27, 56 Exit button 27, 32 Help button 27 menu equivalents 26 Physical View button 27 Rescan System Configuration button 27, 43 Save Configuration button 27, 44

74