Residential Protection Systems Zurn PEX Multipurpose Fire Protection Systems AZurnPEXFireProtectionSystemisamultipurposesystemandisdesigned toprovidesafepassageoutofahomeintheeventofafire.Itisdesigned tosupplyboththefiresprinklerwaterandthecolddomesticwaterandis typicallyinstalledbyalicensedplumbingcontractor.Sincethefiresprinkler systemisconnectedtotheplumbingsystemitisdifficulttobeaccidentally turnedoff,whichaccordingtotheFireAnalysisResearchDivisionofthe ® NationalFire ProtectionAssociation(NFPA)isthemostcommoncauseof ZURNPE X impropersprinkler systemactivation.Assuch,everytimeacoldwaterfixture isusedyoucanbeassuredtheZurnPEXFireProtectionSystemisturnedon. RESIDENTIAL Types of Zurn PEX Multipurpose Fire Protection Systems Accordingtotheinstallationstandardforsprinklersystems,NFPA13Dthe FIREPROTECTION ZurnPEXFireProtectionSystempipingconfigurationmaybegridded,looped, straightoracombinationofthosethree.Thegriddedconfigurationistypically SySTEMS thesimplestdesignwiththebesthydrauliccharacteristicsbecauseasprinkler issuppliedwithwaterfrombothsideswhileotherbranchlineshelptransfer water.Coldwaterfixturesaresuppliedwithbranchandteeconnectionsoff Multipurpose (MP): thegrid.Theloopedconfigurationalsoprovidesasimplisticdesignwithgood Pipingsystemintendedtoserve hydrauliccharacteristics,becausethesprinklersontheperimeteraresupplied colddomesticwater(plumbing) withwaterfrombothsideswhilesprinklerswithintheperimeterarefedoff theloop.Astraightsystemissimilartoateeandbranchsystemfoundina andfireprotectionneeds traditionallyplumbedresidence.Eachsprinklerisprovidedwithasinglepath NFPA 13D: ofwaterfromatrunkline.Ultimatelyitisthedesigner’sdecisiontodecide whichconfigurationwillworkbestinaparticularfloorplan. StandardfortheInstallationof SprinklerSystemsinOne-and How It Works ZurnPEXFireProtectionSystemsaredesignedandhydraulicallycalculated Two-FamilyDwellingsand byacertifiedandlicensedprofessionalinaccordancewithindustrystandards ManufacturedHomes suchasNFPA13D.Inputssuchasroomsize,sprinklercoveragearea,PEX tubesizeandwatersupplypressureareusedinthedesignandhydraulic MP Piping Configurations: calculation.Thedesignandhydrauliccalculationsareprovidedtothelocal Gridded,looped,straight,or authorityhavingjurisdiction(AHJ)forapproval.Acertifiedandlicensed combinationofthosethree installationprofessionalwillfollowthedesign.Aproperlydesignedand installedZurnPEXFireProtectionSystemwillprovideadequateflowtothe Process: sprinklersinthesystem,andthehomescolddomesticwaterneeds. 1. Systemdesignbycertified andlicensedprofessional, 2. Designandcalculations submittedtoAHJforapproval, 3. Certifiedandlicensed professionalinstaller

followsdesign GriddedMultipurpose LoopedMultipurpose FireSprinklerSystem FireSprinklerSystem Why a Zurn PEX System Zurn PEX Tubing • FlexibleZurnPEXtubingisUL1821approvedwith6month UVratingandtheindustrieshighestavailablechlorinerating •Listedforuseinpotablewaterandresidentialfireprotectionapplicationsupto2” • FreezedamageresistantZurnPEXtubing • Resistanttomanychemicalsandsubstancesfoundinwaterandonthejob-site Zurn PEX Fittings and Crimp Systems • ZurnPEXXLlowleadanddezincificationresistantsprinklerteesareUL1821 approved,offerexcellentflowcharacteristicsandaredurableenoughto standuptotoughjobsiteconditions • ZurnPEXXLlowleadanddezincificationresistantbrassfittings1”to2” areUL1821approved •ZurnPEXCRlowleadandcorrosionresistantfittings1”insizeareUL1821approved •ZurnPEXQickClampandcoppercrimpringsystemsareUL1821approved • Bothfittingsandcrimpsystemsarelistedforuseinpotablewaterand residentialfireprotectionapplications

Zurn PEX Tee How Sprinklers Work Therearethreestylesofresidential firesprinklersavailableinthe markettodaywithdifferenttrim andcoverplateoptions: 1. Recessedorsemi recessedpendent 2. Concealedordome andflatplatependent 3.Flushpendent

® Mostresidentialsprinklersoperate Viking Flat Plate Concealed Sprinkler at155°F.Atthattemperature,the glassbulbburstsorthesoldered linkassemblyseparates.Theplug supportedbythebulborsolderlink assemblyisforcedoutandwater isallowedtoflow. Q and A

Q: Why are sprinklers being required by code? A: ResearchconductedbyUnderwritersLaboratories(UL)andtitled“Today’sResidentialFireEnvironment:What’sDifferentTodayandWhyit Matters“identifiedfivefactorsthatleadtofasterfirepropagation,shortertimetoflashover(entirelyengulfedinflames),shortercollapse timeandshorterescapetimeintoday’snewlyconstructedhomes:(1)Largerhomesleadtolongerescapetimeandlargerfiremansearch area;(2)Openspacessuchasgreatrooms,largefoyers,9-14footceilingsarealldesirablehomefeatures,butaddatremendousamount ofairvolume,fuelingafireandeasilyspreading;(3)Increasedfuelloadssuchasthequantityofcontentstypicallysynthetic materi alsthatcarrysufficientenergytobringaroomtoflashover(entirelyengulfedinflames);(4)Voidplacessuchasfloorvoidsand uniqueatticgeometriesallowsfiretospreadquickly;(5)Buildingmaterialssuchasengineeredlumberandsteeltrussplateschangethe fireenvironment.Inall,fireprotectionsystemsallowadditionaltimeforoccupantstoexitastructureintheeventofafire.

Q: When will fire protection systems be required in one and two family dwellings? A: ThemodelresidentialbuildingcodetypicallyadoptedbystatesandlocaljurisdictionsistheInternationalResidentialCode(IRC).The2009 versionofthecodehasmandatedthateffectiveJanuary1,2011residentialfiresprinklersystemsmustbeinstalledinoneandtwofamily dwellings.Theyarenotrequiredforadditionsoralterationsmadetoexistingbuildingsthatdonotalreadyhavesprinklers.Ifyourstateof localcodejurisdictionadoptsthe2009IRCwithoutamendments,firesprinklersystemswillberequired.

Q: What is the typical rate in which states and local jurisdictions adopting a code like this? A: Likeotherbuildingcodestherateofcodeadoptionsvarygreatly.AsofSeptember2010onlyCaliforniaandPennsylvaniahaveadoptedthe 2009IRCwithoutamendments.

Q: What codes must the meet? A: Residentialfiresprinklersystemsmustbedesignedandinstalledinaccordancewithlocalrequirements,typicallyNFPA13Dor SectionP2904ofthe2009IRC

Q: Does every sprinkler activate when a fire occurs? A: No.Residentialsprinklersareheatsensitive.Onlythesprinklerclosesttothefirewillactivateinaresidentialsystem.

Q: What are the chances the sprinkler activates accidentally? A: AccordingtotheU.S.FireAdministration(USFA),thechancesofunintentionalsprinkleractivationareabout1in16milliondevices. Likeaplumbingsystem,whendesignedandinstalledcorrectlythereisverysmallchanceofaleak.

Q: Will the water damage from the sprinkler be more extensive than the fire? A: Onesprinklerputsout90%of.Atypicalresidentialsprinklerwilldischarge15gpmwhilefirehosesnormallyoperateat250gpm. Inaddition,studieshaveshownthattheaveragelossinasprinkleredhomeis$2,166comparedtotheaveragelossinanon-sprinklered homeis$45,019.

Q: Are my smoke detectors and alarms enough protection? A: Smokealarmsalertoccupantstothepresenceofdanger,butdonothingtoextinguishapossiblefire.Homefiresprinklersrespondquickly andsuppressheatandsmoke,providingoccupant’stimetoreachsafety.Themostvulnerableoccupantsarechildrenunder5,seniors, personsimpairedandhouseholdpets.Lastly,smokealarmsfailtoooftenbecausethebatteriesareeitherdeadorhavebeenremoved.

Additional Useful Links: HYPERLINK "http://www.homefiresprinkler.org" www.homefiresprinkler.org HYPERLINK "http://www.firesprinklerinitiative.org" www.firesprinklerinitiative.org HYPERLINK "http://www.ircfiresprinkler.org" www.ircfiresprinkler.org