<<

Passive Protection FACTSHEET

Passive

GLOBAL LEADER IN ADHESIVE TECHNOLOGIES GENERAL INFORMATION Bostik is one of the largest adhesive and sealant Products for are the companies. Worldwide, we employ some 6,000 primary means, included in the of a people in 50 countries across five continents. building, limiting flames, heat and to Our customers come from diverse markets, spread and significantly increase the . most notably the industrial manufacturing, By the right application of these products the construction and consumer sectors. fundamental and legal requirements of creating fire compartments are met. These fire SMART INNOVATIONS compartments contribute to the structural Our smart identity is underpinned by innovation. stability of a building and offer time to safely We pursue innovation vigorously, applying the leave or clear a building. Passive Fire Protection latest technological advances to developing prevents the fire, flames and smoke to leap over ‘smart’ adhesives. Our archives are laden with or through to the adjacent compartment. examples of Bostik technologies that have disrupted markets - from potato starch-based PASSIVE FIRE PROTECTION wallpaper paste to elastic attachment adhesive o Saves lives for diapers. o Limits material damage o Minimalizes business losses Today, our commitment to innovation is as o Protects the construction of a building, strong as ever. We innovate with our customers preserving accessibility after the fire through a global R&D network, comprising three international Smart Technology Centres and 8 The creation of fire compartments in a building regional centres. And we differentiate our is an essential and mandatory part of Passive Fire business through this investment. Protection. The basic idea is to limit and delay the expansion of fire to one compartment. This allows present persons to safely leave the building, and offers time to master and extinguish the fire. Because the importance of Passive Fire Protection is significantly increasing in renovating or building new , Bostik decided to heavily invest in product development and certifications for this market segment. With a huge experience concerning the sealing of linear joints (EN 1366- 4), we proudly present, our completed assortment which also offers solutions for service penetrations (EN 1366-3).

REACTION TO FIRE AND FIRE RESISTANCE On our website, in our brochure and in the Reaction to fire is a completely different matter technical datasheets as well as product leaflets, than fire resistance. Both classifications are you can find all essential information about our strictly regulated in National and International product portfolio and accompanying norms. certification. The certification offers a o Reaction to fire indicates the degree of transparent indication of where the products contribution of a material to the arise and can and cannot be applied to obtain a safe seal expansion of a fire. In other words: How compliant with the required fire resistance. inflammable/flammable is a certain material. Besides we have clear application guidelines A well-known norm for reaction to fire is the available. German DIN4102 part 1, with classifications A1, A2, B1, B2 and B3. o Fire Resistance is the time expressed in minutes which a compartment is able to fulfil its task; preventing the fire to expand out of the compartment. This fire resistance of (combined) products is tested and measured with standardized and frequently occurring situations. This means in fact, a product can have the highest classification for reaction to fire but does not offer any guarantee for a higher fire resistance.

PORTFOLIO FOR LINEAR JOINTS (EN 1366-4) POSSIBLE SOLUITIONS EN 1366-4 A fire compartment exists of fire resistant walls, For linear Bostik is able to ceilings and floors. A compartment is completed offer a resistance of EI30 up to EI240, depending by a and fire retardant sealing of movement on substrates, orientation of the joints and the and connection joints between these building product combinations. In our brochure components. Products and systems tested complete tables, overviews and according EN1366-4 are applied to fully seal and recommendations are displayed to provide the close fire compartments where walls, floors and correct duration of the retardancy and the ceilings meet. Most of these products to seal product combinations. linear joints are developed to adopt movements between the building components. Our SUBSTRATES solutions for sealing linear joints: o Stone / (horizontal & vertical) o BOSTIK FP401 FIRESEAL ACRYLIC o Stone / (horizontal & vertical) o BOSTIK FP402 FIRESEAL SILICONE o Stony materials (vertical) o BOSTIK FP403 FIRESEAL HYBRID o Stone walls ≥100 mm (vertical) o BOSTIK FP404 FIRE RETARDENT PU GUN o Stone walls ≥115 mm (vertical) FOAM o Stone / and plaster / plaster (horizontal & vertical) The Fire resistance of our solutions to seal linear o Stone walls and floors / ceilings (horizontal) joints are tested by certified labs (notified bodies) conform National and International norms. The results of these tests are summarized in clear test reports and classification reports. These specifically developed products can be applied separately. We have also tested combinations of products offering a solution for every occurring situation.

PORTFOLIO FOR SERVICE PENETRATIONS (EN MORE INFORMATION 1366-3) If you need more information, please contact Compartment walls and floors have recesses your local Bostik Sales Representative. containing service installations as tubes and electrics. A Fire compartment is only completed LIABILITY and functional when these recesses are securely All supplied information is the result of our tests sealed with the right products. Our solutions for and experience and is of general nature. sealing service penetrations: However they do not imply any liability. It is the o BOSTIK FP310 ACOUSTIC responsibility of the user to verify by his own ACRYLIC tests if the product is suitable for the o BOSTIK FP311 INTUMENSCENT application. o BOSTIK FP312 FIRE RETARDANT o BOSTIK FP320 FIRE BATT o BOSTIK FP330 COLLAR o BOSTIK FP340 PIPE WRAP o BOSTIK FP350 GRAPHITE PLATE o BOSTIK FP360 PUTTY CORD o BOSTIK FP370 FIRESEAL

The Fire resistance of our solutions to seal recesses are tested by certified labs (notified bodies) conform National and International norms. The results of these tests are summarized in clear test reports and classification reports.