Butler/Butler2/ ButlerX/Linear iTempo Plus Control PUR100474 06-15 AromaSteam SteamHead PUR100421 10-15 Linear SteamHead PUR103936 04-21 SteaLinx PUR100518 01-18 MS / Super AutoFlush PUR100200E 10-15 MX AutoFlush PUR100532 02-19 Condensation Pan TS0012 02-19

2021-07-16 Installation, Operation & Maintenance Manual

iTEMPO® & iTEMPOPLUS® CONTROLS

mr.steam® Feel Good Inc. www.mrsteam.com 2 When installing and using this electrical equipment, basic safety Hyperthermia occurs when the precautions should always be followed, including the following: internal temperature of the body IMPORTANT SAFETY INSTRUCTIONS reaches a level several degrees above the normal body temperature of 98.6° 1. READ AND FOLLOW ALL INSTRUCTIONS F. The symptoms of hyperthermia 2. ! WARNING Supervise children at all times. include an increase in the internal temperature of the body, dizziness, 3. ! WARNING Steam is hot and can cause injury or death if improperly used. Steam rooms contain steam and ele- lethargy, drowsiness, and fainting. The vated temperatures. Please read and observe all warnings effects of hyperthermia include: in this manual before installing or using a steam room. a) Failure to perceive heat; 4. ! WARNING To reduce the risk of injury: b) Failure to recognize the need to exit A. The wet surfaces of steam enclosures may be slippery. the steambath; Use care when entering or leaving. c) Unawareness of impending risk; B. The steam head is hot. DO NOT touch the steamhead and avoid the steam near the steamhead. d) Fetal damage in pregnant women; C. Prolonged use of the steam system can raise exces- e) Physical inability to exit the steam- sively the internal human body temperature and impair bath; the body’s ability to regulate its internal temperature and (hyperthermia). Limit your use of steam to 10-15 min- f) Unconsciousness. utes until you are certain of your body’s reaction. D. Excessive temperatures have a high potential for caus- ! WARNING ing fetal damage during the early months of pregnancy. The use of alcohol, drugs, or medica- Pregnancy or possibly pregnant women should consult a tion can greatly increase the risk of physician regarding correct exposure. hyperthermia. E. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath. F. Persons using medication should consult a physician before using a steambath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation. SAVE THESE INSTRUCTIONS

3 ® ______mr.steam Installation & Operating Instructions

READ ME FIRST! Table of Contents:

! WARNING As you follow these instruc- Important Safety Instructions...... 3 tions, you will notice warning and caution symbols. This blocked information is impor- Before Installing­...... 5 tant for the safe and efficient installation Dimensional Information...... 6 and operation of this generator. These are types of potential hazards that may occur Installations...... 7-9 during installation and operation: iTempo Operating Instructions...... 10-11 iTempoPlus Operating Instructions...... 12-15 ! WARNING Indicates a potentially hazardous situation, which, if not avoided, Care and Maintenance...... 16 could result in death or serious injury. Warranty...... 16

! CAUTION Indicates a potentially Template for Control Installation...... 17 hazardous situation, which, if not avoided may result in minor or moderate injury or product damage.

IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.

All information in these instructions is based on the latest product information available at the time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.

4 ® ______mr.steam Installation & Operating Instructions BEFORE INSTALLING Carefully inspect the control and packaging for shipping MrSteam technical service 1-800-767- 8326 for damage. In the event of shipping damage, please contact more information on the Remote Temperature the carrier for claim information. Our customer service de- Probe. partment can assist you with any missing or damaged parts. ! WARNING Do not route iTempoPlus, iTempo, ! CAUTION To avoid unintentional steambath HomeWizard or iGenie control wiring inside conduit operation, do not locate the control where other controls, together with power lines or close to hot water or accessories, shower heads, valves, body sprays or similar steam piping. Doing so may result in an inoperative the shower could cause confusion or interfere with or hazardous installation. the MrSteam control’s intended use and function. ! WARNING Do not alter or modify any MrSteam Do not use any iTempoPlus®, iTempo®, HomeWizard® or product. Doing so may result in an inoperative or iGenie® controls without reading and understanding the hazardous installation and will void the warranty. respective Installation and Operation Manual and MrSteam important notes: steam generator Installation and Operation Manual. Failure • Turn power to the steam generator OFF before to read and understand these instructions may result in an connecting the control to the generator. Failure inoperative or hazardous installation. to turn the power off will result in an inoperable ! WARNING A peel and stick warning sticker is provided control. in the MrSteam steam generator Installation, Operation • Do not operate iTempoPlus, iTempo, Home and Maintenance Manual. This manual is provided with Wizard or iGenie controls with anything other every steam generator. The warning sticker must be read than a MrSteam iTempo compatible steam gen- and permanently affixed in a conspicuous location near the erator. MrSteam residential steam generators steam room. Failure to read and affix this warning sticker in with serial numbers lower than 900000, or any a conspicuous location may result in serious injury or death. other brand of steam generator are not to be op- Please call MrSteam at 800 767-8326 for a free replacement erated with iTempo controls. Doing so may result or if you have any questions regarding the warning sticker. in an inoperative installation. Install the iTempo or iTempoPlus controls according to • This document contains important safety, opera- installation instructions. Failure to install according to in- tion and maintenance information. Leave this structions will result in an inoperative control or hazardous document with the homeowner. Do not discard overheating or inadequate heating of the steam room. this document. Failure to install according to instructions will result in an inoperative control and overheating of the steam room. • Discontinue use of the steam generator or control if the steam generator is damaged or otherwise important note: If the desired location for the control not functioning properly. Doing so may result in is outside the steam room a Remote Temperature Probe an inoperative or hazardous installation. (MSTS) must be installed inside the steam room. Contact • All illustrations are for illustrative purposes only.

5 ® ______mr.steam Installation & Operating Instructions

Dimensional Information for the Round and Square iTempo® and iTempoPlus® 1 1” 4 /2”

3/8”

1 2 /2” 5”

1/4” Box Contents: • iTempo or iTempoPlus Control • Control Cable (30 ft.) 5” • Steam head • Tube of Silicone sealant • Owner’s Manual

3 3 /4” 3 /4”

12” long pigtail

Drawings for Illustrative Purposes Only. 6 ® ______mr.steam Installation & Operating Instructions

Installation Instructions for Round & Square iTempo® and iTempoPlus® IMPORTANT NOTE: If the desired location for the control is outside the steam room a Remote Temperature Probe (MSTS) must be installed inside the steam room. Contact MrSteam technical service 1-800-767- 8326 for more information on the Remote Temperature Probe. NOTE: The connector is keyed with the flat facing up. The control cable is the same at both ends.

Step 1 Determine the desired installation location of the control. The iTempo and iTempoPlus controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed inside the steam room the control must be located: • 4-5 feet above the floor near the bather seating area.

• The control features an integral temperature sensor. Locate the control in a 5 location representative of the desired steam bathing temperatures. Do not 2- ⁄8” locate the control above or near the steam head or direct steam emissions. Locating the controls near the steamhead or near direct steam emissions may result in poor steam room temperature control. • On a vertical wall • The control cable length is 30 feet. Insure that the control and/or steam generator are located accordingly. Contact a MrSteam technical service representative if a longer cable is required (60 ft. cable, PN 103990-60). 3-7⁄8” IMPORTANT NOTE: The control cable should be run in a dedicated 1” conduit to facilitate installation and service. Be careful not to strain, staple, pinch or otherwise damage the control cable. Route cable as required to permit replacement. Do not route cable inside conduit together with power lines or close to hot water or steam piping. Diagram 1

Drawings for Illustrative Purposes Only. 7 ® ______mr.steam Installation & Operating Instructions

Step 2 Diagram 1 Make a 2-5⁄8” wide by 3-7⁄8” high cutout in the desired control location. Do not oversize or under size the cutout. Step­ 3 Diagram 2 Route the control cable (provided with the Diagram 2 control) from the wall cutout to the steam generator. Connect one end of the cable to the steam generator connector. NOTE: The connector is keyed with the flat facing up. The control cable is the same at both ends.

Step 4 Diagram 3 Firmly connect the other end of the cable to the control. Turn on power to the steam generator and test the control to verify correct connections. Test per Diagram 3 the instructions on pages 10-15. With verification of proper control function, proceed to Step 5.

! CAUTION If the generator is on for more than a few minutes steam will start coming out of the steamhead. Insure that the steam room is not occupied. Diagram 4

Drawings for Illustrative Purposes Only. 8 ® ______mr.steam Installation & Operating Instructions

Step 5 Diagram 4 Remove and discard peel-off paper to expose adhesive liner. Diagram 5 Step 6 Diagram 5 Run a bead of silicone (provided) as shown to the outer edge of the control faceplate, following the contour of the circle or square shape. Use silicone as required to create a moisture seal. Note: The silicone supplied by MrSteam can be used to meet a variety of sealing and gasketing. It cures to silicone rubber and Diagram 6 adheres to glass, wood, metal, porcelain, ceramic tile, painted surfaces, many plastics and rubber. Surfaces must be clean and dry. Apply thin layer of product. Fit together and support if necessary. Allow excess material to cure, then trim with a sharp blade. Sealant “skins” in 5 minutes, dries to touch in 1 hour. Fully cures and bonds in 24 hrs. important NOTE: Do not apply excessive amounts of silicone. Do not apply silicone to any other parts of the control including the adhesive gasket. Step 7 Diagram 6 Insure the mounting surface is clean and dry as required for good adhesion. Hold the control with the LED display in the 12 o’clock position and press the control against the wall u­ntil the adhesive sticks

Drawings for Illustrative Purposes Only. 9 ® ______mr.steam Installation & Operating Instructions iTempo® Operating Instructions

The iTempo Control features programmable digital temperature control, a fixed (60) minute duration, ON/OFF and PAUSE. The control can be set at a temperature range from 80˚f up to 120˚f ! WARNING Set the steam bathing temperature according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting for a very short duration to gauge comfort and safety levels. Diagram 1 ON/OFF Diagram 1 Press the ON/OFF key to start or stop the flow of steam. Steam will begin to flow a few minutes after the control is turned ON. The duration re- quired for the steam room to reach steam bathing temperatures depends on the steam room construction and steam generator specifica- tions. Steam may continue to flow for a short time after the control is turned OFF. PAUSE feature Diagram 2 If a pause in steam flow is desired press the PAUSE key. The display will flash while the control is in the PAUSE mode. The timer will continue to countdown while in the PAUSE mode. Steam may continue to flow for a short time after pause is pressed. Diagram 2

Drawings for Illustrative Purposes Only. 10 ® ______mr.steam Installation & Operating Instructions

Timer Feature When the control is turned ON a 60 minute time duration is initiated. The control will turn off after 60 minutes unless the control is turned off manually.

Memory Feature If the control is turned off manually before 60 minutes then the default temperature of 110˚F will be used the next time the control is turned on. If the control times out at 60 minutes (not manually turned off) then the previous user tem- Diagram 3 perature setting will be used when the steam- bath is used again.

Setting the Temperature Diagram 3 The control is pre-set and will display the tem- Display perature setting of 110˚F (default setting). Use the UP and DOWN keys to change the tempera- mr.steam ture setting from 80˚ F to 120˚ F in one degree increments. Up Key Pause Key

Changing the Temperature Down Key Units (F˚/C˚) Diagram 4 ON/OFF When the generator is Off, Press and hold ON/ Key OFF key for 10 seconds. The temperature units will be displayed as Fahrenheit (TuF) or Celsius Diagram 4 (TuC). Use the UP/DOWN keys to choose between (TuF) and (TuC). Press ON/OFF key to accept the new units and exit.

Drawings for Illustrative Purposes Only. 11 ® ______mr.steam Installation & Operating Instructions iTempoPlus® Operating Instructions

The iTempoPlus Control features programmable temperature control, programmable time duration, clock, AromaSteam, ChromaSteam®, ON/OFF and two personal settings. mr.steam

WARNING Set the steam bathing temperature ! temp time according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting for a very short duration to gauge aroma chroma comfort and safety levels.

POWERING UP THE UNIT Diagram 1 Diagram 1 When the generator is first powered up or after a power interruption, the clock display flashes and the clock is ready to be set up. Note: Pressing the ON/OFF will start the generator even if the clock has not been set. Note: The clock can only be set when the generator mr.steam is OFF, the display is flashing.

SETTING THE CLOCK temp time ON/OFF Diagram 2 Press the ON/OFF key to start or stop the flow of aroma chroma steam. The Temperature Set Point is displayed. Steam will begin to flow a few minutes after the control is Diagram 2 turned ON. The duration required for the steam room to reach steam bathing temperatures depends on the steam room construction and steam generator speci- fications. Steam may continue to flow for a short time after the control is turned OFF.

Drawings for Illustrative Purposes Only. 12 ® ______mr.steam Installation & Operating Instructions

Setting the Clock Diagram 3 When the display is not flashing: Press and hold the mr.steam TIME key until the display starts flashing. Use the UP/DOWN keys to select the desired time, Diagram 3 temp at this time the AM/PM logo will be displayed.

Press the TIME key to save changes. aroma

Setting the steambath Duration Diagram 4 Press TIME key to set or display the steambath duration time on the clock. The control is pre-set and will display a TIME setting of 20 minutes (de- fault setting). With the TIME or CLOCK displayed, press the UP or DOWN keys (Diagram 5) to set the Diagram 4 desired duration time ­(2-60 minutes) in two minute increments. Set the steambath duration according to personal preference, however it is highly recommended to begin steam bathing at a very short duration to gauge comfort and safety levels. The control will turn off when the duration period times out. Then, the clock time will be displayed.

Diagram 5

Drawings for Illustrative Purposes Only. 13 ® ______mr.steam Installation & Operating Instructions

Setting the Temperature Diagram 6: Press TEMP key to set the desired temperature or display the temperature setting. Diagram 7: The control is preset and will display a tempera- mr.steam ture setting of 110˚F (default setting). With the temperature Diagram 6 displayed, press the UP or DOWN keys to set the desired tem- time perature (80°F to 120°F) in one degree increments. Set the steam bathing temperature according to personal aroma chroma preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels.

Memory Feature If the control is turned off manually before it times out then the default settings of 20 minutes and 110°F will be used the next mr.steam time the control is turned on. If the control times out (not manu- Diagram 7 ally turned off) then the previous user time and temperature temp time settings will be used when the steambath is turned on.

PERSONAL SETTINGS Diagram 8 chroma Use the program key to store preferred settings. To program preferred settings: Press ON/OFF key to turn generator on. Press the Program key once to program Pr 1. Press it twice to program Pr 2. The selected parameter will be displayed. Enter the preferred time and temperature settings. Diagram 8 mr.steam The iTempoPlus will store the following settings: set point, time duration & aroma state. To select Pr 1 or Pr 2: temp time Press ON/OFF key then press the Program key once to select Pr 1, press it twice to select Pr 2. The steambath will aroma chroma begin to operate at the stored settings.

Drawings for Illustrative Purposes Only. 14 ® ______mr.steam Installation & Operating Instructions

Changing the Temperature units (˚F/˚C) When the generator is Off, Press and hold ON/OFF aroma key for 10 seconds. The temperature units will be displayed as Fahrenheit (TuF) or Celsius (TuC). Use mr.steam the UP/DOWN keys to choose between (TuF) and (TuC). Press ON/OFF key to accept the new value temp time and exit.

AromaSteam Diagram 9 chroma The AromaSteam is an optional accessory that automatically injects aromatic oil into the steam. Diagram 9 Press the ON/OFF key to turn the steam genera- tor on. Then, press the AROMA key. The Aroma indicator will be displayed. The AromaSteam turns off automatically when the steam genera- tor stops heating. Press the AROMA key to turn it off during a steam session. The indicator will chroma turn off. mr.steam ChromaSteam® Diagram 10

The ChromaSteam is an optional accessory that temp time provides colored light in the steam room. Press the CHROMA key to turn light on. Press twice to select the next color. Press again to turn the light aroma off. Note that the light can be turned ON even if the steam generator is OFF. Diagram 10

Drawings for Illustrative Purposes Only. 15 ® ______mr.steam Installation & Operating Instructions

Display

mr.steam

Up Key Time Display/ Time Display/ Adjust Key temp time Adjust Key Down Key

ON/OFF Key aroma chroma Program Key AromaSteam ChromaSteam Key Key

Care Tips for all Controls and Steamheads 1. Use only mild soap and water on a soft cloth to clean the control and steamhead. 2. Do not use abrasive cleansers 3. If the decorative cover is damaged on the iTempo® or iTempoPlus® call MrSteam technical service for replacement parts. NOTE: Replacement of the decorative covers requires removal and reinstallation of the control from the mounting surfaces.

Warranty To register your steam generator unit online and to review the MrSteam Limited Lifetime Warranty please go to: blog.mrsteam.com/wr

Drawings for Illustrative Purposes Only. 16 ® ______mr.steam Installation & Operating Instructions

template for control installation (see pg.7)

­

2-5⁄8”

3-7⁄8”

17 mr.steam® Feel Good Inc.

Products, information and specifications are subject to change without notice.

For more information call Sales & Support at: 1.800.76.STEAM (East Coast) 1.800.72.STEAM (West Coast)

2019 © Sussman-Automatic Corporation MrSteam and des., AromaFlo, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time, Club Therapy, Digital 1, Express Steam, From Bathroom to Spa, iDream Pack- age, iGenie, iSizing, iSteam, MusicTherapy, Spa Package, Steam@Home, Steam Therapy, Sussman, Valet Package, Virtual Spa System, Voice Genie and Voice Wizard are registered trademarks of Sussman-Automatic Corporation. AudioWizard, HomeWizard, iButler, iTempo, iTempoPlus, Smart Sizing, SteamStart, The Intelligent Steambath are trademarks of Sussman-Automatic Corporation. pur 100474 ­­ rev 10.19 mr .stea m® STEAM HEAD ______1/8" minimum clearance required INSTALLATION INSTRUCTIONS when Acrylic Shield is used. See installation instructions Use Teflon ® or equal provided with the Acrylic Shield. IMPORTANT: See the Installation and Operation Manual sealant on pipe threads provided with the steam generator for additional important steamhead & control installation and operation information. Steam Supply Pipe 1 Installation: Steam Head ( ⁄2" NPT)

CAUTION Apply with silicone or ! INSTALLER: Because the steam head and direct equal sealant as required End of pipe to be recessed steam emissions are very hot, locate the steam head where incidental for moisture seal. 1/4" (without Acrylic Shield) contact by bather with the steam head or direct steam emission cannot 1/8" (with Acrylic Shield) occur. Oil Well STEP 1 Locate steam head 6-12 inches above floor, except for: 1. Tub/shower enclosures, install 6 inches above tub top edge. STEP 3 2. For enclosures with acrylic or other non-heat resistant flooring install Acrylic Shield Part Number MS-103938. 3. To prevent door seals from deteriorating do not locate the steam head where direct steam emission would contact door seals. STEP 2 Install steamhead with the oil well facing up as shown. Hand tightening is sufficient when teflon or equal pipe thread sealing com - pound is used. Drop Ear IMPORTANT NOTE: to preserve steam head finish, do not use Fitting wrench or other tools to tighten. DO NOT use abrasive cleansers or chemicals. Use only water with mild soap and a non-abrasive sponge. ! CAUTION Consult with supplier of acrylic, fiberglass and other STEP 4 non-heat resistant enclosures for recommended steamhead location. Use Acrylic Shield part number MS-103938. See instructions provided with steam shield. STEP 3 Secure a bronze drop ear fitting to a header and run a 1/2" copper steamline from the steam generator to the drop ear fitting. Install a temporary nipple (6" or longer)in the drop ear fitting to locate the steamhead after the wall is finished.

STEP 4 After the wall has been finished, mark on the nipple where the STEP 5 surface of the wall is. Remove the nipple and measure the portion that 1 was in the wall (the end to your mark). Subtract ⁄4" from that dimen - sion and select a brass nipple of that length to finish the installation. STEP 5 Wrap teflon tape around the threads of the new nipple and screw the nipple into the steamhead. Do not use wrenches or tools which would damage the steamhead's finish. Wrap teflon tape around the threads of the nipple and screw the nipple and steamhead assem - bly you just made into the drop ear fitting in the wall. The steamhead should be flush with the wall and the well must be facing up. Steamhead (shown with 7 optional acrylic shield) /8” 1” 1 3” 3 /2” Locating Nipple

3 3” 2 /4”

0 3” All drawings are for illustrative purposes only

PUR 100421 10.15 mr.stea m® Sussman-Automatic Corp® [email protected] www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944 Installation, Operation and Maintenance Manual

Linear Steam Head Residential Model: 104480

______MPORTANT: Leave this material with the homeowner. _ IMPORTANT:______Leave__ this_ _material_ __ with__ the_ homeowner.__

mr.steam® Feel Good Inc.® ® Linear Steam Head ®

Model 104480

TABLE OF CONTENTS

Important Safety Information ...... 1-2

Installer Section:

Box Contents ...... 3 Dimensional Information ...... 3 General Installation ...... 4

Faceplate ...... 5

Installer and Home Owner Section:

Steam Emission Zone ...... 6 Diverter ...... 7 AromaTray ...... 8 Replacement Parts ...... 9 Warranty ...... 9 Essential Oils ...... 10

® mr.steam Sussman-Automatic Corp® [email protected] www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM PUR103936 Rev 04/21 ® Linear Steam Head ®

Installer Section Model 104480

READ ME FIRST! As you follow these instructions, you This highlights information that is especially will notice and symbols. This relevant to a problem free installation. information is important for the proper, safe and trouble free installation of the Linear Steam Head. These are types of All information in these instructions is based on the latest potential hazards that may occur if installation instructions information available at the time of publication. Sussman- are not carefully followed: Automatic Corporation reserves the right to make changes at any time without notice. This signals a situation where injury or property damage may occur if you do not follow instructions.

The following general information should be near a seat,bench or any space occupied by any persons. used in conjunction with consultations with a qualified Failure to following these directions may result in a architect, designer and contractor in determining factors hazardous condition, scalding or personal injury. necessary in providing a suitable and safe steam room. Linear Steam Heads are for residential use This document contains important safety, only. Do not use any Linear Steam Heads for commercial operation and maintenance information. After installation installations or with commercial steam generators (including leave these instructions with the homeowner. Do not discard Day Spas). Using Linear Steam Heads for commercial this instructions. Failure to leave the instructions with the installations or installations with commercial steam homeowner may result in property damage or personal injury. generators may result in a leak within the wall cavity and cause problems associated with leaks, moisture and Use one or more Linear Steam Heads for property damage from leaks. Using Linear Steam Heads for MrSteam steam generator models MS90 – MS400 and commercial installations or installations with commercial MSSUPER1–MSSUPER3, SAH3000-SAH6000. steam generators may result in a hazardous condition, scalding or personal injury. Use two or more Linear Steam Heads for MrSteam steam generators Models MX4, MX5 and MX6. Do not use the Linear Steam Head with any Failure to use two or more steam heads may result in steam steam system that includes equipment or devices not head operation where incidental contact by the bather with supplied by MrSteam, including but not limited to water direct steam emission may occur. Failure to use two or more softeners. Failure to follow these instructions may result in a steam heads may result in a leak within the wall cavity and leak within the wall cavity and cause problems associated cause problems associated with leaks, moisture and with leaks, moisture and property damage from leaks. property damage from leaks. Failure to use two or more Failure to follow these instructions may result in a hazardous steam heads may result in a hazardous condition, scalding or condition, scalding or personal injury. personal injury. Only install the linear steam head in a Do not use Linear Steam Head for any horizontal orientation as shown in 3. Failure to follow MrSteam steam generator that is not one of the following these instructions may result in a leak within the wall cavity models: MS90 –MS400, MSSUPER1–MSSUPER3, SAH3000- and cause problems associated with leaks, moisture and SAH6000 or MX4 –MX6. Failure to follow these instructions property damage from leaks. Failure to follow these may result in a leak within the wall cavity and cause instructions may result in a hazardous condition, scalding or problems associated with leaks, moisture and property personal injury. damage from leaks. Failure to follow these instructions may result in a hazardous condition, scalding or personal injury. Insulate the linear steam head and piping as required to prevent elevated temperatures, including within Do not use the Linear Steam Head with any the wall cavity. Do not locate the steam head or plumbing near steam system that is not a MrSteam steam system. Failure to any materials, including wiring, devices, or products that may follow these instructions may result in a leak within the wall be adversely affected by elevated temperatures. Check with cavity and cause problems associated with leaks, moisture and the manufacturer of materials, wiring, devices, or products for property damage from leaks. Failure to follow these instructions suitability for operation at elevated temperatures. Use only may result in a hazardous condition, scalding or personal injury. insulation rated for 212F or higher steam applications. Failure to follow these instructions may result in the damage or failure Because the steam head and direct steam of materials, wiring, devices, or products. Failure to follow emission are very hot, locate the steam head(s) where these instructions may result in leaks, and cause problems incidental contact by the user with the steam head(s) or associated with leaks, moisture and property damage from direct steam emission cannot occur. Do not locate the steam leaks. Failure to follow these instructions may result in a head(s) in any location where the steam emission zone is hazardous condition, scalding or personal injury.

1 ® Linear Steam Head ®

Installer Section Model 104480

Steambath controls feature an integral or accessories...etc.). If the installation and operation manuals are remote temperature sensor that senses room temperature. not available go to www.mrsteam.com for an online copy, or Install the linear steam head in a location where steam contact MrSteam Customer or Technical Services at 800-767- emission will not come in direct contact with the control or 8326 or 800-727-8326 for free copies. Failure to read and remote temperature sensor. Failure to follow these follow all the Installation and Operation Manuals may result in a instructions may result in poor temperature control, a leak within the wall cavity and cause problems associated with hazardous condition, scalding or personal injury. leaks, moisture and property damage from leaks. Failure to follow these instructions may result in inoperable system Only use the supplied high temperature components, a hazardous condition, scalding or personal injury. silicone sealant as required to create a permanent moisture seal. Do not seal the steam head with grout or any other Consult with the manufacturer of any non- material. Failure to follow these instructions may result in heat resistant enclosures for elevated temperatures, steam, leaks, and cause problems associated with leaks, moisture moisture compatibility or for suitability for use with steam. and property damage from leaks. Failure to follow these instructions may result in the damage or failure of materials or products. Failure to follow these The linear steam head must be installed by a instructions may result in leaks, and cause problems qualified and licensed plumber. Failure to use a qualified associated with leaks, moisture and property damage from and licensed plumber may result in a leak within the wall leaks. Failure to follow these instructions may result in a cavity and cause problems associated with leaks, moisture hazardous condition, scalding or personal injury. and property damage from leaks. Failure to follow these instructions may result in elevated temperatures, a Do not install a Linear Steam Head in an hazardous condition, scalding or personal injury. acrylic/fiberglass tub or shower enclosure. Failure to follow these directions may cause problems associated with leaks, Do not use black iron, galvanized, or plastic moisture and property damage from leaks. Failure to follow pipe for the steam line. Use only properly rated brass pipe these instructions may result in elevated temperatures, a or copper tubing in accordance with national and local hazardous condition, scalding or personal injury. plumbing codes. Using any piping material other than properly rated brass or copper piping may cause linear Do not locate the steam head where steam, steam head damage and problems associated with leaks, elevated temperatures, moisture or water can contact any moisture and property damage from leaks or steam. products, wall surfaces, materials, door seals, devices, electronics that are not designed for use with steam, Plumb rigid copper tubing or brass pipe from elevated temperatures, moisture or water. Failure to follow the steam generator to the linear steam head. Plumbing these instructions may result in damage or improper must not form traps or valleys. Failure to follow these operation of the products, wall surfaces, materials, door instructions may result in leaks, and cause problems seals, devices or electronics. associated with leaks, moisture and property damage from leaks. Failure to follow these instructions may result in a The optional diverter reduces the steam hazardous condition, scalding or personal injury. emission zone by redirecting steam up the wall above the steam head (see page 6). Installation of the diverter may Do not modify or alter the linear steam head. result in the following: Do not cover, block or insert any product that is not a • Changes to the steam distribution in the room MrSteam supplied linear steam head accessory with the • Increase of the temperature of the wall and devices above linear steam head. Failure to follow these instructions may the steam head result in a leak within the wall cavity and cause problems • Surface condensation patterns on the walls and ceiling associated with leaks, moisture and property damage from Always test the diverter to insure proper safety, installation leaks. Failure to follow these instructions may result in a and comfort. hazardous condition, scalding or personal injury. Carefully inspect the Linear Steamhead and Do not disassemble the steam head. The steam packaging for shipping damage. In the event of shipping head is shipped fully assembled and requires no additional damage, please contact the carrier for claim information. assembly. Failure to follow these instructions may result in a Our customer service department can assist you with leak within the wall cavity and cause problems associated with product replacement. leaks, moisture and property damage from leaks. Do not use abrasive cleansers or chemicals to Before installing the linear steam head, read clean the linear steam head. Use only water with mild soap and follow the Installation and Operation Manual(s) provided and a non-abrasive sponge. The use of abrasive cleansers or with all system components ( generator, controls, chemicals will damage the finish on the linear steam head. 2 ® Linear Steam Head ®

Installer Section Model 104480

Bracket Adjustment Screws

Adjustable Brackets

P104481 - Linear Steam Head

104483 - Faceplate BOX CONTENTS: • Linear Steam Head • AromaTray 104484 - Diverter • Faceplate • Silicone Sealant • Diverter • Installation Instructions 104482 - AromaTray Figure 1

Linear SteamHead 11 Dimensional Information 2-2 4/4" ” shown without the

optional faceplate 1 1-1 16/16"” or diverter.

Slotted Mounting Holes 3/4” NPT Steam Inlet

Steam Outlet 1 9- 9 4/4" ” 5 5 /8”"

14” 11 2- 2 8/8"” Slotted Mounting Holes 1 14- /8” - 19”

Figure 2 NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 3 ® Linear Steam Head ®

Installer Section Model 104480

Linear SteamHead Steam Head Installation shown without the STEP 1. Confirm proper stud spacing: The studs optional faceplate must have a minimum spacing of 14-1/8” and a or diverter. maximum spacing 19". If the stud spacing is outside the required range then shim or otherwise reposition Copper Tubing Bracket the studs as required. or Brass Pipe Adjustment Screws (Not Supplied) Installing the steam head between incorrectly spaced studs may result in damage to the steam head and result in a leak within the wall cavity and cause property damage.

STEP 2. Locate the steam head 6-12” above the finished floor. Locate the steam head where a steam bather can not come into contact with direct steam emissions. See page 6 for information on the steam emission zone.

Steam is hot. Locate the steam head where a steam bather can not come into contact with direct steam emissions. Failure to follow these directions may result in a hazardous condition, Steam Outlet scalding or personal injury. Level

Stud Steam Head Face STEP 3. Position the steam head between 2 14 1 properly spaced studs. Extend the adjustable /8” - 19” brackets as required so the steam head fits snugly between two studs. Use a level to ensure the steam head is level (see Fig. 3). Tighten the eight bracket adjustment screws (supplied). Stud STEP 4. If the optional decorative faceplate is used, see the installation instructions for the optional faceplate Figure 3 on page 5. If the optional decorative faceplate is not used, VAPORVapor BARRIER Barrier position the steam head so that the steam head face will be flush with the finished wall face (see Fig. 4). CEMENT BOARD Cement Board STEP 5. With the stem head properly positioned, with or without a decorative faceplate, provide eight screws as required to securely ThinThin Set Set mount the steam head brackets to the studs. FinishedFinished Wall Surface Failure to position the steam head face as instructed may Wall Surface result in improper steam head alignment, or a leak within the wall cavity and cause problems associated with leaks, moisture and property damage from leaks.

STEP 6. Plumb rigid copper tubing or brass pipe from the steam generator to the steam head. Use a ¾” NPT fitting appropriate for the SiliconeSilicone steam piping used. Plumbing must not form traps or valleys. Thread Steam Outlet Outlet Face Face sealant must be used as required to ensure a leak free joint between 1 the piping and steam head. Flush or Recess 8 "

STEP 7. Before continuing or closing the wall, test the installation, SiliconeSilicone piping and steam head for leaks, traps, position, steam emission zone and for general proper installation.

Failure to test the steam head installation may result in leaks, and cause problems associated with leaks, moisture and property damage from leaks. Figure 4

NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 4 ® Linear Steam Head ®

Installer Section Model 104480

Optional Faceplate Installation Thin Set The steam head is supplied with an optional faceplate. It is not required for the functional operation of the steam head. The faceplate is a decorative accessory and is Vapor Barrier Finished available in (8) finishes. Wall Surface

An optional Escutcheon (remodel plate) is available for Silicone purchase, it's larger than faceplate and is available in (8) Cement Board finishes.

In STEP 4, instead of positioning the steam head face Faceplate to be flush with the finished wall face, position the steam head so that the steam head face will be 1/8” recessed with the finished wall (see Fig. 4). This will provide clearance for the faceplate. Silicone Figure 4 Apply silicone to the front of Linear Steam Head and firmly press the faceplate against the face of the steam head. Secure the faceplate as required until the silicone sets. Apply Silicone on surface Return to STEP 5 on page 4 to complete the installation.

Faceplate

Figure 5

1. Determine the desired installation location of the control. 60 foot cable is available, PN 103990-60 for iTempo and PN The iSteam®, iTempo™ and iTempo/Plus™ controls are 104117-60 for iSteam. Contact a MrSteam technical service designed to be installed inside or out-side the steam room representative if a 60 foot cable is required. as a matter of personal prefer-ence. If the control is installed inside the steam room the control must be located: IMPORTANT NOTE: If the control is installed outside the 2. 4-5 feet above the floor near the bather seating area steamroom a Remote Temperature Probe Part Number MSTS must be installed inside the steam room, depending on the control. Insure MrSteam steam generator is iSteam or iTempo 3. The control features an integral temperature sensor. Locate compatible and has a serial number 900000 or higher. If the control in a location representative of the desired iSteam is used with a generator having serial number less than steambathing temperatures. 1174000, contact MrSteam technical support for an upgraded Do not locate the control above or near the steam head or PC board. direct steam emissions. 4. On a vertical wall See instructions for the MSTS Temperature Probe (located in The control cable length is 30 feet. Insure that the control the Control Installation Manual related to your specific control and/or steam generator are located accordingly. An optional package) before rough-in or installation of control.

NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 5 ® Linear Steam Head ®

Installer and Home Owner Section Model 104480

Steam Emission Zone The Steam Emission Zone is the area in front of the steam head that contains dense, hot steam as it exits the steam head. Steam dissipates as it moves away from the steam head, and becomes less hot. The steam zone is the area where contact with steam presentees a scalding hazard. The steam head must be installed in a location to ensure that a steam bather will not be near the steam emission zone. The diverter reduces the steam emisson zone.

Steam Head without Optional Diverter Steam Head with Optional Diverter

Steam Emission Steam Emission

Without With Diverter Diverter

Finished Finished Wall Wall 6”-12” 6”-12” Above Floor Above Floor Steam Steam Emisson Zone Emission Zone

Steam Room Steam Room Interior Interior

Minimum # of Steam Emission Steam Emission Generator Linear Steam Zone Zone Model Heads with Diverter without Diverter

MS90-MS400 1 2” 10” SAH3000-SAH6000 Super1-Super3 1 2” 24” MX4-MX6 2 2” 24”

The steam emission zone may vary with each installation. Always test the steam emission zone to insure safety.

NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 6 ® Linear Steam Head ®

Installer and Home Owner Section Model 104480

Diverter

The Linear SteamHead is supplied with an optional steam diverter. The steam diverter is used to reduce the steam emission zone as required to avoid contact between a steam bather and direct steam emissions.

Supplied steam diverter does not have decorative finish. Steam diverters with decorative finish are available for purchase.

Always use the diverter if any steam bather may come into contact with direct steam emissions. Contact MrSteam if a replacement diverter is required. Failure to use a diverter to reduce the steam emission zone as required to avoid contact between a steam bather and direct steam emissions may cause personal injury.

Because direct steam is very hot, the diverter will be hot during the steam session, and will remain hot for a period of time after steam session. Never install, remove or adjust a diverter when the steam head is hot or if steam generator is turned on. Installing, removing or adjusting the diverter when the steam head is hot or if the steam generator is turned on may cause a burn hazard and personal injury.

The optional diverter reduces the steam emission zone by redirecting steam up the wall above the steam head ( see page 6 ). Installation of the diverter may result in the following: • Changes to the steam distribution in the room • Increase of the temperature of the wall and devices above the steam head • Surface condensation patterns on the walls and ceiling Always test the diverter to insure proper safety, installation and comfort.

STEP 1. Securely press the two rubber extensions into the opening of Linear Steam Head and push in firmly until the diverter is securely in place. (see Fig. 7).

Rubber Extensions

Diverter Rubber Extensions

Figure 7

NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 7 ® Linear Steam Head ®

Installer and Home Owner Section Model 104480

AromaTray The AromaTray is for use with MrSteam Essential Oils. Place a few drops of Rubber Portion Essential Oils in the AromaTray as shown to provide a fragrant steam bath for secure placement experience. Read the instructions provided with the MrSteam Essential oils to insure a pleasant and safe aromatic steam bathing experience.

Steam emissions, the linear steam head and AromaTray will all be hot during a steam bath session, and will remain hot for a period of Reservoir for time after the steam bath session. To avoid contact with the steam head Essential Oil and steam emissions, never install the AromaTray during a steam bath session or for a period of time after the steam bath session. Touching the AromaTray during a steam bath session, or for a period of time after the steam bath session, may result in burns, scalding or personal injury.

Failure to first read the instructions provided with the MrSteam Essential oils may result in personal injury. If you do not have the instructions provided with the MrSteam Essential oils please call MrSteam customer or technical at 80076STEAM for a free copy, or go online at www.mrsteam.com.

AromaTray placement with the steam head or optional face plate

Firmly insert the rubber portion of the AromaTray into the steam outlet of Linear Steam Head with the oil reservoir facing up. Place a drop or two of AromaSteam essential oil in AromaTray. (see fig. 8)

AromaTray

Figure 8

AromaTray placement with the optional diverter

If a diverter is being used, firmly insert the rubber portion of the AromaTray onto the diverter with the oil reservoir facing up. Place a drop or two of AromaSteam essential oil in AromaTray. AromaTray (see fig. 9)

Diverter

Figure 9

NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 8 ® Linear Steam Head ®

Using MrSteam Essential Oils Model 104480

Enjoy Mr.Steam essential oils by placing a drop or two, into your Mr.Steam AromaTray as shown in the illustration. Only use EnjoyMr.Steam Mr.Steam essential essential oils in oils a Mr.Steam by placing AromaTray. a drop or two,Contact into a your MrSteam Mr.Steam customer AromaTray or technical as shown Service in the representative illustration. Only for essentialuse Mr.Steamoil Manufacturer essential Safety oils in Data a Mr.Steam Sheets ( AromaTray.MSDS ). Contact a MrSteam customer or technical Service representative for essential oil Manufacturer Safety Data Sheets ( MSDS ). Start with one drop to gauge strength and suitability. Limit to a maximum of a few drops during a steambathing Start with one drop to gauge strength and suitability. Limit to a maximum of a few drops during a steambathing session. PUR 1000616 session. PUR 10006 Use essential oils with caution. Essential oils are for external use only. Keep out of reach of children. Essential oils a drop or Use essential oilsSome with peoplecaution. essential may find oils thatare for the external aroma use only.makes Keep them out of dizzy reach ofand children. Essential oils a dropare or highly concentrated and are potent substances and should not be applied directly to the as they can be irritants. Use wn inareessential the highly oils concentrated with caution. and areSomethe potent user people substances should may exit and find shouldthe that steambath not the be aromaapplied IMMEDIATELY directlymakes to them the skin dizzyand as they breathe and can be irritants. Use own inessential the oils with caution. the user should exit the steambath IMMEDIATELY and breathe essential in fresh air. If skin irritation occurs stop using the oils right essential Place the drops into the Mr.Steam AromaTray recess prior to turning on the steambath. Do not place drops in a

hot steamhead Place as serious the drops injuryinaway. into freshcan the resultRemove Mr.Steamair. if youIf skinany doAromaTray not excessirritation follow recess thisoil warning. occurspriorby washing to turning stop inonusing mildthe steambath.the soap oils and rightDo water. not place drops in a

SA

U

1

0 .

1

ts

1

i

ion.

1

t

ir

,

u

p hot steamhead as SERIOUS INJURY CANY RESULT IF YOU DO NOT FOLLOW THIS WARNING.

l

s o

N he

s

t

nto

nd y, s o i

c

t

a

so

oil

y

wo Ci d

t

mati

o

to

nd

tial

ro

d b

or n a la

a

s e

ur

p

s

I he

o s

o

r

our

ng

am

e y

away. Remove d any excess oil by washing in mild soap and wate o

m e

a

oy te

re

L

s ,

f

g

r

nj

tea

n

n a

E et

i

S

Fo

e

c

m

r.

io

and

am-

s o

la tr

t

A

M

e

r n

. S

p

S

t

p

a

o

s

i U

ep

y

ri

oy

t

e

t

b j

ren

c

c

1

4th

K n

d

u

0

. .

l

ho

E

i s

1 n

es

.

tr

t

1

o i n

e

s

D

20 3 r s 1

o

ch

ti

i

f only. u

,

u

p

3- r

Y

l

e s r

e In e

o 4

o

N

h

h to :

ou s

d

t

,

us

pe Se

c

n

p

n

y s

o

m i

c

a B .

o l

l

t

i

i

r i

a

a

t

o ea

so

ot o

p

y

n a

C

t

re

REV

w n

ead

f

l d

S o

t m

d h

a

t o

r. i

o ter

n

r

ns

b

t

ro

t o

x

d

a

359 M

D

4

o

o

9 ly n

a l

u

e r a

0

1

s

e

o

0 D e u

I p

r

8 O s r

P

cti

h

o

u s

o

3

o

g

y

r

e

o

0 m se

F

n

l

d ire

uses n

a

1

bs,

e PUR1

o

y

m

ts r

o

D a

L

o

te

a

e re

Mu

j

s ,

f

g

r

n

t

H en

te PN-

n

-

n

o i a E

e

d

i

S

ga

F nati

.

o c d n

m

m

u

i

r

a

a

a

s ho, S

e o

l tre

ti

b

M

e

r

r n

o

.

S

p

t

p

p

a

o P

m g

n i

y

s

i

e

y h

r

e

o n

o t

t e

t

b j

r

I

c c

c

4

o K n

ps clear d

s u

l

3

h .

E

i

M

e

.

y

tr

n.

h

l

m

0 A

n

e

s

D

o c

o

n

E 2

s

i

o

n

hel

ical

c - t

f I o u

.

3 r

o

ra at ST

r

e e

4 u

o

sman

s

e

e h

h

: o

eam s

ntail Oil 76

u

t

p

S

c

t p

rp

u

m

trop

a B

.

o l e

S

o

a

t rs

r ed e

V

a d

A

f

s e

C

r

r

E o

p

a m

t

e

800

R

n

rn

e

f ®

S

1

ic

.

e

k o st

h

s

o

9 t

i

r Es

o t

r

ww.

a

5

n

g

t

x

y

3 M D

4

e w

o 9 l

u

e

ma 0

i r

1

om BREATHE o

s t

0 D

t

8 O

r

P

c

1

e

a

3

de- o

, R e

s

a Au

Is 0 se

F

s r

U

l r

i

u n

1

s

b

t P

u

-

t r

n o

D

i

e M

n

N

ti

s

H e

P a a

i

r

,

g

n

d

a o

u

i

h S

e

b

l re

o

c P m g

l tability. Limit

n o i

s

I

p

c

O

l

l

. M

e

a

n

m

l

A

o

c

o

E

i

h

i

n c

t T .

t

a

ai

p S

ra a

m

E AromaSteam 10ml bottle with integrated dropper o

a 6

o sm

h

r

e s 7 p

t

t

r

u

t

d

0 ent

S

TH o

rs

e

0

A f

s

C r

8

m AromaSteam 10ml bottle with integrated dropper A

o

e .

s

c

® t

1 i

w

E

k s

t

i

E

r

w

a

g

a

R

e w

m

m r

o

B -

t a

e

u

d

s

a A I r tability. Limit t athing session. AromaSteamAromaSteam 10ml bottlebottle with with integrated integrated dropper dropper athing session. Recess for essential oil Recess for essential oil

are for external Mr.Steam AromaTray AromaSteam Steamhead are for external Mr.Steam AromaTray ra oils are AromaSteam Steamhead ra oils are s and should Reservoir for essential oil s and should Reservoir for essential oil be irritants. In case of contact with eyes, rinse immediately with plenty of be irritants. Some people Inmay case find thatof contactthe aroma withmakes eyes, them dizzy.rinse In theimmediately event of dizziness, with theplenty user shouldof exit the steambath immediately and breathewater inand fresh seek air. If medical skin irritation advice. occurs Ifstop ingested, using the oilsrinse right mouth away. Remove with any excess oil by washing in mild Some soap people and water maywaterwater. find and thatAdminister theseek aroma medical makeswater themadvice. or milkdizzy If and toingested, dilute.the user shouldContactrinse exitmouth thea physician steambath with immediately and breathe in fresh air. If skinwater. irritation Administer occurs stop using water the oilsor rightmilk away. to dilute.Remove Contactany excess oila physicia by washingn in mild soap m steamheadand water. In case of contactimmediately. with eyes, rinse Tightly immediately close with containers plenty of water when and storingseek medical oils. advice. Keep If ingested, rinse mnot steamhead place mouth with water. Administerimmediately.away water fromor milk tosources Tightlydilute. Contact of close ignition. a physiciancontainers immediately. when storing Tightly close oils. containers Keep when storing not placeoils. Keep away fromIn case sources of contactaway of ignition. with from eyes, sources rinse immediately of ignition. with plenty of water and seek medical advice. If ingested, rinse CAN mouth with water. Administer water or milk to dilute. Contact a physician immediately. Tightly close containers when storing RNING.CAN oils. Keep away from sources of ignition. RNING.

0 S. La Cienega Blvd ® 0e wood,S. La CienegaCA 90301 Blvd ewood, 1-800-72-STEAM CA 90301 : 1-800-72-STEAM

WARRANTY

To view or download the MrSteam Residential Generator Warranty and register your product go to: blog.mrsteam.com/wr

For Installation assistance please call Customer or Technical support: ForEast Installation Coast 1-800-767-8326 assistance please West call Coast Customer 1-800-727-8326 or Technical support: EastTo view Coast an 1-800-767-8326installation video West please Coast go to:1-800-727-8326 www.mrsteam.com. This video is for added visual assistance only. ToDo view not installan installation the Linear video Steam please Head go using to: www.mrsteam.com. the video. Use only This these video installation is for added instructions visual assistance for a safe andonly. problem free Doinstallation. not install the Linear Steam Head using the video. Use only these installation instructions for a safe and problem free installation.

NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. NOTE: Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction. 99 ® Linear Steam Head ®

Model 104480

mr.steam®

104482 - AromaTray 104483 - Faceplate ® P104481 - Linear Steam Head, Feel Good104484 - Diverter Inc. SteamHead only Replacement Parts Optional Accessories

Part Number Description Part Number Description 104482BB AromaTray for LSH, Brush Bronze 104485BB LSH Escutcheon Brush Bronze 104482BN AromaTray for LSH, Brush Nickel 104485BN LSH Escutcheon Brush Nickel 104482MB AromaTray for LSH, Matte Black 104485MB LSH Escutcheon Matte Black 104482ORB AromaTray for LSH, Oil Rubbed Bronze 104485ORB LSH Escutcheon Oil Rubbed Bronze 104482PB AromaTray for LSH, Polish Brass 104485PB LSH Escutcheon Polish Brass 104482PC AromaTray for LSH, Polish Chrome 104485PC LSH Escutcheon Polish Chrome 104482PN AromaTray for LSH, Polish Nickel 104485PN LSH Escutcheon Polish Nickel 104482SB AromaTray for LSH, Satin Brass 104485SB LSH Escutcheon Satin Brass 104483BB LSH Faceplate Brush Bronze 104486BB LSH Diverter Brush Bronze 104483BN LSH Faceplate Brush Nickel 104486BN LSH Diverter Brush Nickel 104483MB LSH Faceplate Mattewww.mrsteam.com Black 104486MB LSH Diverter on Matte Black 104483ORB LSH Faceplate Oil Rubbed Bronze 104486ORB LSH Diverter Oil Rubbed Bronze 104483PB LSHProducts, Faceplate information Polish Brass and specifications are subject104486PB to change without LSH notice. Diverter Polish Brass 104483PCPlease call Technical LSH Support Faceplate at 1.800.76.STEAM Polish Chrome (East Coast) or 1.800.72.STEAM104486PC (West Coast)LSH Diverter for more Polish information. Chrome 104483PN The LSH model Faceplate and serial Polish number Nickel is printed on the data104486PN plate on the front of the LSH steam Diverter bath generator. Polish Nickel 104483SB Have LSH this Faceplate information Satin available Brass when contacting Technical104486SB Service. LSH Diverter Satin Brass

® mr.steam Sussman-Automatic Corporation® I [email protected] I www.mrsteam.com

43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM I 9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM

2020 © Sussman-Automatic Corporation I MrSteam and des., A Lifetime of Pleasure, AirTempo, AromaFlo, AudioWizard, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time, Club Therapy, CT Day Spa, Digital 1, Express Steam, Feel Good Inc., From Bathroom to Spa, HomeWizard, iButler, iGenie, iSpa Package, iSteam, iTempo, iTempo/Plus, Linear Steamhead, Making Wellness a Way of Life, Music Therapy, My Steam, SmartSizing, Spa Package, Steam Genie, Steam on Demand, Steam in a Box, Steam@Home, SteamStart, SteamTherapy, Sussman, Tala, Tala Bath & Body, Tempo, The Intelligent Steambath, Valet Package, and Virtual Spa System are registered trademarks of Sussman-Automatic Corporation. PUR103936PUR103936 RevRev 10/2004/21 10 INSTALLATION INSTRUCTIONS SteamLinx Module and Mobile App allows for seamless Package Contents: control of time and temperature using your smart phone • SteamLinx A with Integral Cable • SteamLinx B and Ethernet Cable or mobile device. SteamLinx works with all MrSteam • Power Supply and Cable controls (for MS generators SN 1174000 and up). • Instructions

These instructions contain safety alert symbols and panels. These alert symbols Indicates a potentially hazardous and panels identify potential safety hazards and provide important information situation, which, if not avoided, may result in for the installation and use of SteamLinx. death or serious injury. Read the Installation, Operation and Maintenance Manual for Steambath Generator Indicates a potentially hazardous Systems (PUR100472) before installation of SteamLinx to insure safety and proper situation, which, if not avoided, may result in installation of the steam Generator. A free replacement manual is available by minor or moderate injury or product damage. calling MrSteam Customer Service, or it can be downloaded from mrsteam.com is used to address practices not All drawings for schematic purposes only. related to physical injury.

Notice alert SteamLinx A and B 1 signal range is limited max. distance of 60ft. Connecting SteamLinx A to the Steam Generator • Disconnect power to the generator Generator at the breaker box. Cover • Locate the SteamLinx A (with the integral cable).

To prevent shock hazard, disconnect power at the breaker box before removing generator cover • Remove knock-out. • Remove generator cover. Knock-out in Circuit the Generator • Route the SteamLinx A cable Board Jacket through the knockout Cover ELECTRICAL SHOCK HAZARD. Screws MrSteam steam generators are connected to 240V line voltage and contain live electrical components. All installation and service must be performed by a licensed and qualified electrician.

• Locate the circuit board. • Plug the SteamLinx A into the white connector located at the far left side of the circuit board. • Replace cover and screws. • Restore power.

ELECTRICAL SHOCK HAZARD. MrSteam steam generators are connected to 240V line voltage and contain live electrical components. All installation and service must be performed by a licensed and qualified electrician. 2 Connecting SteamLinx B to the Home Router Home Router • Plug the blue ethernet cable provided, into an ethernet slot on the back of the home router. Power • Plug the power Supply supply into a 120V outlet.

3’ Cable Ethernet Cable (3’)

3 Connecting SteamLinx to the Internet • Insure the mobile device is on the WiFi network. • Download the SteamLinx App from the Apple Store or by following prompts.

Troubleshooting: Indicator Lights 4 Troubleshooting: Blinking LED Units are out of range or not paired LEDs • Turn breaker off. Yellow Blinking units are in pairing mode. • Insure SteamLinx A is connected to the steam generator. • Use a paperclip or similar blunt end object to press the reset Red Router not detected: problem with button (above the LED) on SteamLinx B. connections, router configuration • The LED will flash yellow (it stays in pairing mode until it or steam generator circuit board. is paired or powered off). Green SteamLinx B: router is detected but • Turn the breaker to the steam generator ON, if the two is not connecting to the internet. transmitters are functioning correctly and within range The indicator light on SteamLinx A the LEDs will turn blue. will not be illuminated. • If the Blue, Green or Red LEDs are blinking the units are not pairing Blue Units are connected correctly. because they are out of range. Using an extension cord for power, move the SteamLinx B closer to SteamLinx A. Disconnect the ethernet cable (the router connection is not required for this test). If the LEDs stop blinking this confirms the units were out of range.

5 Tech Service Contact 6 Warranty CUSTOMER and TECH SUPPORT To view or download the SteamLinx warranty and register, go to Web: Visit mrsteam.com for additional informaton including product specifications, locating a device, sizing blog.mrsteam.com/wr calculator, technical downloads and other resources. Call: Mon.– Fri.: 8 am - 7 pm East Coast: 1.800.767 STEAM (8326) West Coast: 1.800.727 STEAM (8326) Worldwide: 1.718.937.4500

Sussman-Automatic Corporation® I [email protected] I www.mrsteam.com

43-20 34th Street, Long Island City, NY 11101 800 76 STEAM PUR 100518 7.19 mr .stea m® Optional AutoFlush ® System ______INSTALLATION INSTRUCTIONS

BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.

ASSEMBLY OF OPTIONAL AUTOFLUSH ® SYSTEM

3 Pin Connector for AutoFlush

AutoFlush Cord Connector

AutoFlush Cord

Steam Generator AutoFlush Valve

End "B" End "A" ¬ Plumb to Drain Valve Nipple copper or Drain Line (shown in the correct open position) brass nipple 1 DO NOT REMOVE THIS DRAIN VALVE 1" NPT x 3 ⁄2" or longer (not supplied ) Arrow indicates correct direction of flow

OPERATION The optional AutoFlush System feature automatically drains the MrSteam system following each use. A time delay allows the water to cool down (about two hours) before it drains resulting in a safe and gentle operation.

PUR 100200 Rev 9.19

mr.stea m® Sussman-Automatic Corp ® [email protected] www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 1 800 76 STEAM I 9410 S. La Cienega Blvd. Inglewood CA 90301 1 800 72 STEAM INSTALLATION INSTRUCTIONS AutoFlush ® Shown Fully Assembled 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable National and Local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve out - let is threaded 1/2" NPT. Check plumbing code for receptor, trap and vent requirements. 1 Steam 2. Use copper or brass nipple 1/2" NPT x 3 ⁄2" (90mm) or longer Generator AutoFlush Valve (not supplied ) to connect AutoFlush valve (end "B") to the Drain Valve (valve end “A” and “B” are indicated on bottom of AutoFlush Valve)

! CAUTION DO NOT REMOVE THE DRAIN VALVE Nipple Removal may cause equipment and property damage. If there Drain Valve DO NOT TURN OR Plumb to Drain Line is not enough room for the valve, an elbow and a short nipple REMOVE THE DRAIN VALVE (shown in the correct open position) (not provided ) can be added. 3. Open Drain Valve (handle must be aligned with brass nipple). 4. Connect the AutoFlush System cord connector to the three pin Installing AutoFlush on Older Model connector as shown. Generators SN:899,999 and below

! WARNING Do not drain into a steam enclosure or any location where accidental contact with drain water may occur. In the event of a power failure the AutoFlush System valve will open and may discharge boiling water.

SWEAT FITTINGS When using sweat fittings use only tin base solder with a melting point below 600 degrees F. Do not overheat. Ends of water sup - ply tubing must be thoroughly clean for a minimum distance of 1" from ends. Do not remove valve cover.

TO CHECK OPERATION 1. Turn on MrSteam with the control and allow tank to fill with 1. Remove the connector from the "C" location water. (see MrSteam Instruction Manual) in the jacket. Cut off the connector where 2. Turn off MrSteam with the control. Water should stay in tank. shown and strip back the wires approx 0.375" 3. Turn off power at the panel box. Water should discharge 2. Cut the connector off the AutoFlush cable from tank. where shown and strip back the wires approx 4. Turn on power at panel box. 0.375". 5. Repeat 3. Remove the knockout in the side of the gener - ator and install a bushing to prevent chafing. ! CAUTION PROVIDE DRAIN PLUMBING ACCORDING 4. Route the wires from the AutoFlush through TO LOCAL CODES. PLUMB AS REQUIRED FOR AUTOFLUSH the knockouts and connect the white wire from the AutoFlush to the white wire from the SYSTEM. circuit board using a wire nut. Repeat for the black wire.

IMPORTANT NOTE: Contact the MrSteam Technical Service Dept. WARRANTY: To view or download the MrSteam Controls for installation of any equipment not shown in these instructions. & Accessories Warranty and register your product go to: East Coast: 800-767-8326; West Coast: 800-727-8326 blog.mrsteam.com/wr mr .stea m® Optional AutoFlush ® System ______INSTALLATION INSTRUCTIONS

BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.

ASSEMBLY OF OPTIONAL AUTOFLUSH ® SYSTEM

3 Pin Connector for AutoFlush

AutoFlush Cord Connector

AutoFlush Cord

Steam Generator

AutoFlush Valve

Drain Valve (shown in the correct open position) Nipple copper or ¬ Plumb to brass nipple End "B" Drain Line DO NOT REMOVE THIS DRAIN VALVE 1 1" NPT x 3 ⁄2" or longer (not supplied ) End "A" Arrow indicates correct direction of flow OPERATION The optional AutoFlush System feature automatically drains the MrSteam system following each use. A time delay allows the water to cool down (about two hours) before it drains resulting in a safe and gentle operation.

PUR 100532 Rev 2.19 mr.stea m® Sussman-Automatic Corp ® [email protected] www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 1 800 76 STEAM I 9410 S. La Cienega Blvd. Inglewood CA 90301 1 800 72 STEAM INSTALLATION INSTRUCTIONS AutoFlush ® Shown Fully Assembled 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1" NPT. Check plumbing code for receptor, trap and vent requirements. 1 Steam 2. Use copper or brass nipple 1" NPT x 3 ⁄2" or longer Generator AutoFlush Valve (not supplied ) to connect AutoFlush valve (end "B") to the Drain Valve (valve end “A” and “B” are indicated on bottom of AutoFlush Valve)

! CAUTION DO NOT REMOVE THE DRAIN VALVE Nipple Removal may cause equipment and property damage. If there Drain Valve DO NOT TURN OR Plumb to Drain Line is not enough room for the valve, an elbow and a short nipple REMOVE THE DRAIN VALVE (shown in the correct open position) (not provided ) can be added. 3. Open Drain Valve (handle must be aligned with brass nipple). 4. Connect the AutoFlush System cord connector to the three pin connector as shown.

! WARNING Do not drain into a steam enclosure or any location where accidental contact with drain water may occur. In the event of a power failure the AutoFlush System valve will open and may discharge boiling water.

SWEAT FITTINGS When using sweat fittings use only tin base solder with a melting point below 600 degrees F. Do not overheat. Ends of water supply tubing must be thoroughly clean for a minimum distance of 1" from ends. Do not remove valve cover.

TO CHECK OPERATION 1. Turn on MrSteam with the control and allow tank to fill with water. (see MrSteam Control Instruction Manual) 2. Turn off MrSteam with the control. Water should stay in tank. 3. Turn off power at the panel box. Water should discharge from tank. 4. Turn on power at panel box. 5. Repeat

! CAUTION PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.

IMPORTANT NOTE: Contact the MrSteam Technical Service Department for installation of any equipment not shown in these instructions. East Coast: (800) 767-8326; West Coast: (800) 727-8326

WARRANTY: To view or download the MrSteam Controls & Accessories Warranty and register your product go to: blog.mrsteam.com/wr ® mr .stea m Technical Specifications

Condensation Pan 103867 & 104402

Mr.Steam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level. All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes. Check local plumbing code for receptor, trap and vent requirements. Condensation pans drain by gravity.The condensation pan is equipped with an integral 3⁄4" NPT fitting.

103867 9”

25” 1.5” 104402

NOTE: For MX4E, MX5E and MX6E use model 104402

FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.

MODEL PROJECT INFORMATION I 103867 Location: Contractor: 104402 I Architect: Submitted By: Engineer: Date:

Notes:

® TS0012 REV 2.19 mr.stea m Sussman-Automatic Corp ® [email protected] www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 TEL : 1 800 76 STEAM 9410 S. La Cienega Blvd. Inglewood CA 90301 TEL : 1 800 72 STEAM