IEMA 206 Rad Info for the Emergency Worker.Pdf

Total Page:16

File Type:pdf, Size:1020Kb

IEMA 206 Rad Info for the Emergency Worker.Pdf DETECTING IONIZING RADIATION IONIZING RADIATION CANNOT BE DETECTED BY ANY OF THE FIVE SENSES. ince ionizing radiation cannot be detected by human senses, special INTRODUCTION Sequipment is needed to detect and measure it. Emergency workers are furnished with instruments and devices that n emergency is an unexpected situation or record exposure to radiation. One type, the Aoccurrence of a serious nature that demands direct-read dosimeter, enables the emergency SEE immediate action. Because accidents involving worker to readily obtain readings that relate to HEAR radiation may occur at nuclear power stations, we the United States Environmental Protection need to prepare ourselves for this type of emer- TOUCH gency. This section of the training guide provides Agency (U.S. EPA) and Illinois Plan for Radio- TASTE information on radiation and how emergency logical Accidents (IPRA) exposure limits. A workers may protect themselves from its poten- second type, a luminescent dosimeter badge SMELL tially harmful effects. (LD), though not directly readable, provides a permanent record of the emergency worker’s exposure. DOSIMETRY KITS osimetry for emergency Dworkers is prepackaged to accelerate and simplify the issuing process during emer- gency situations. 24 21 RADIATION BASICS TYPES OF IONIZING RADIATION here are four basic types of ionizing radiation: alpha particles, beta WHAT IS RADIOACTIVITY AND RADIATION? Tparticles, gamma rays, and x-rays. While all types of radiation are po- tentially harmful, they differ in the manner in which they affect us. adioactivity is the natural process of unstable atoms releasing their Rexcess energy. This emission, or giving up energy, is called radiation. Alpha Particles have a very low penetrating ability and can be stopped by a Radiation can be either man-made or occur naturally in the very thin sheet of paper or the outer layer of skin. They are not an external environment. It is divided into two types: non-ionizing and ionizing. hazard, but once they are inhaled or ingested, they become very hazardous. Non-ionizing radiation is the type of radiation associated with the operation of many of the conveniences that we use in our daily lives: for Beta Particles have a low penetrating ability and can be shielded or stopped example, the energy that microwave ovens emit to cook our foods and the by thin sheets of metal or thick plastic. Depending on the energy of beta waves of energy that transmit our radio and television signals. particles, it can cause burns ranging in severity from minor (similar to a Ionizing radiation is the type of radiation associated with nuclear sunburn) to extreme (blistering similar to third-degree burns from fire). power generation. Because of its ability to cause damage to any Because beta particles are also harmful if inhaled or ingested, they are both organism, it is important to understand how to protect yourself from an internal and external unnecessary exposure. There are many additional uses of ionizing hazard. radiation, which include: medical x-ray, radioactive material used in medical diagnosis and treatment, industrial manufacturing, and in the Gamma Rays and X-rays production of many consumer products such as cigarettes, smoke detectors are waves similar to light and some gas lantern mantels. ALPHA waves, but have higher Besides the radioactive materials that are man-made, ionizing radiation energy levels. Lead, steel, BETA occurs naturally in rocks and eventually works its way into the soil, trees, concrete or water are com- plants, ground water, and even into materials in the human body. Another GAMMA important source of naturally occurring ionizing radiation is the sun and monly used to shield this outer space, which produces a continuous exposure to all living organisms type of ionizing radiation. on this planet. We call naturally occurring radiation background Although scientists make a radiation. distinction between x-rays and gamma rays, the impor- tant difference is that gamma rays are usually more energetic and there- fore more penetrating. 22 23 FRACTIONAL UNITS COLLECTION OF RADIOLOGICAL SAMPLES he fractional units, milliroentgen, millirad, and milliRem, are used to ■ Escort radiological monitoring teams T measure and describe small quantities of radiation. The prefix, “milli,” ■ Escort and/or assist sample collection personnel means 1/1000th of a roentgen, rad, or Rem. For example, 1,000 mR equals 1 R. DECONTAMINATION OF EQUIPMENT AND STREETS ■ Set up monitoring stations on perimeter of affected areas ■ Wash down vehicles, streets, etc. upon recommendation of IEMA ■ Wear normal protective gear for personal contamination protection CONTINUATION OF ROUTINE PUBLIC SERVICES ■ Law enforcement and crime prevention ■ Emergency medical services ■ Fire/rescue services in affected areas To simplify communications and the reporting or exchange of informa- tion, the terms R and mR are used instead of the scientific terminology. 26 19 UNITS OF MEASUREMENT RADIATION IS MEASURED IN THREE BASIC UNITS: Part II UNIT DEFINITION ROENTGEN (R) — The roentgen is the unit of exposure and is a measure of the ionization produced in air by gamma rays and x-rays. Direct-read dosimeters record exposure in roentgens. RADIATION ABSORBED Radiological Hazard DOSE (rad) — The rad is the unit of absorbed dose and is a measure of the energy deposited in matter by ionizing radiation. & ROENTGEN EQUIVALENT Exposure Control MAN (Rem) — The Rem is the unit of dose equivalent and is the measure that accounts for the varying effects of different types of ionizing radiation on the human body. An understanding of the differences in these units is important in the scientific study of ionizing radiation. In nuclear power station accidents or radiation emergencies, however, the terms roentgen, rad, and Rem are used interchangeably. Therefore, for this purpose, a roentgen is equal to a rad is equal to a Rem. 20 25 EXPOSURE RATE AND EXPOSURE RECOVERY, RE-ENTRY AND RETURN xposure rate is a measurement of the rate of exposure over some nsite recovery operations consist of all the steps taken to return the nuclear Eperiod of time, usually an hour. For example, if a reading from an expo- Opower station to an operational status. Due to the fact that recovery plans will sure rate meter was 1 R/hr and an individual remained in the area where this be based on the specific on-going events, much of the recovery planning will take reading was taken for one hour, the direct-read dosimeter would register an place during the emergency. Exelon will formulate the onsite recovery plans. exposure of 1 R. Offsite recovery involves the process of determining when radiation exposure rates and concentrations of radioactive material in the environment have returned to acceptable levels for the return of the general public for unconditional occupancy or use. Re-entry is the temporary entry of individuals into a restricted zone under controlled conditions. Re-entry is allowed so that necessary functions can be performed in the restricted area. Return is defined as the return of the general population to an evacuated area. This includes provisions for notification and transportation of evacuees. The emergency situation must be ended prior to return, and the evacuated area determined safe by IEMA. Environmental teams will be deployed throughout areas affected by a radiological accident at a nuclear power station. These teams will be equipped with a variety of instruments for measuring exposure rates. The readings obtained from these instruments will be relayed to an IEMA repre- sentative at each affected county Emergency Operation Center. This infor- mation will be distributed to all Dosimetry Control Officers (DCO) respon- sible for controlling the exposure of emergency workers. 28 17 FUNCTIONS OF THE EMERGENCY PROTECTING YOURSELF WORKER FROM IONIZING RADIATION he IPRA coordinates the efforts of Federal, State and local governmental T agencies. These governmental agencies are made up of personnel referred to EFFECTS OF TIME, DISTANCE, AND SHIELDING as “Emergency Workers”. The role played by these emergency workers is vital to ime, distance, and shielding, when used effectively, will help protect the successful implementation of the IPRA, and more importantly to the safety and you from ionizing radiation. welfare of the EPZ population. T Emergency workers may be assigned to perform one or more of the following Time The less time you spend in a radiation area, the less tasks: exposure you will receive. ■ For example, if you were working in an area where the PUBLIC NOTIFICATION exposure rate was 100 mR/hr and you stayed there for ■ Utilize squad cars or vehicles equipped with mobile PA systems one hour, you would receive an exposure of 100 mR. If ■ Inform citizens of recommended protective actions you remained there for only 30 minutes, you would receive an exposure of 50 mR. TRAFFIC AND ACCESS CONTROL ■ Distance The farther away you are from a source of ionizing Staff traffic and access control posts radiation, the less exposure you will receive. ■ Direct traffic ■ When assigned tasks in a radiation area are completed, ■ Monitor traffic conditions ■ Maintain access control into affected areas emergency workers will be reassigned to unaffected ■ Deliver and erect barricades locations. ■ Provide roving security Shielding The use of shielding between you and a source of ionizing ■ Maintain clear roads radiation will reduce your exposure. ■ The amount of reduction depends on the type and density EVACUATION OF GENERAL POPULATION, of the shielding material. SCHOOLS AND SPECIAL CONCERNS ■ When possible, emergency workers in radiation areas ■ Notify individuals in affected areas should take advantage of shielding behind buildings, ■ Provide bus transportation automobiles, trucks, or any other means of shelter to ■ Provide special transportation for disabled citizens, shut-ins, etc. reduce their exposure. ■ Register evacuees at Reception Centers 18 27 LEVELS OF EXPOSURE PROTECTIVE ACTIONS rotective actions are the specific actions implemented by Federal, State, county BIOLOGICAL EFFECTS OF IONIZING RADIATION Pand local emergency response organizations to minimize radiation exposure during an accident at a nuclear power station.
Recommended publications
  • The Utilization of MOSFET Dosimeters for Clinical Measurements in Radiology
    The Utilization of MOSFET Dosimeters for Clinical Measurements in Radiology David Hintenlang, Ph.D., DABR, FACMP Medical Physics Program Director J. Crayton Pruitt Family Department of Biomedical Engineering J. Crayton Pruitt Family Department of Biomedical Engineering Medical Physics Program Conflict of interest statement: The presenter holds no financial interest in, and has no affiliation or research support from any manufacturer or distributor of MOSFET Dosimetry systems. J. Crayton Pruitt Family Department of Biomedical Engineering Medical Physics Program The MOSFET Dosimeter • Metal oxide silicon field effect transistor • Uniquely packaged to serve as a radiation detector – developed as early as 1974 • Applications – Radiation Therapy Dose Verification – Cosmic dose monitoring on satellites – Radiology • ~ 1998 - present J. Crayton Pruitt Family Department of Biomedical Engineering Medical Physics Program Attractive features • Purely electronic dosimeter • Provides immediate dose feedback • Integrates over short periods of time • Small size and portability • Simultaneous measurements (up to 20) J. Crayton Pruitt Family Department of Biomedical Engineering Medical Physics Program Demonstrated radiology applications – Patient dose monitoring/evaluation • Radiography • Fluoroscopic and interventional procedures • CT • Mammography J. Crayton Pruitt Family Department of Biomedical Engineering Medical Physics Program Principles of operation • Ionizing radiation results in the creation of electron-hole pairs • Holes migrate and build up
    [Show full text]
  • Personal Radiation Monitoring
    Personal Radiation Monitoring Tim Finney 2020 Radiation monitoring Curtin staff and students who work with x-ray machines, neutron generators, or radioactive substances are monitored for exposure to ionising radiation. The objective of radiation monitoring is to ensure that existing safety procedures keep radiation exposure As Low As Reasonably Achievable (ALARA). Personal radiation monitoring badges Radiation exposure is measured using personal radiation monitoring badges. Badges contain a substance that registers how much radiation has been received. Here is the process by which a user’s radiation dose is measured: 1. The user is given a badge to wear 2. The user wears the badge for a set time period (usually three months) 3. At the end of the set time, the user returns the badge 4. The badge is sent away to be read 5. A dose report is issued. These steps are repeated until monitoring is no longer required. Badges are supplied by a personal radiation monitoring service provider. Curtin uses a service provider named Landauer. In addition to user badges, the service provider sends control badges that are kept on site in a safe place away from radiation sources. The service provider reads each badge using a process that extracts a signal from the substance contained in the badge to obtain a dose measurement. (Optically stimulated luminescence is one such process.) The dose received by the control badge is subtracted from the user badge reading to obtain the user dose during the monitoring period. Version 1.0 Uncontrolled document when printed Health and Safety Page 1 of 7 A personal radiation monitoring badge Important Radiation monitoring badges do not protect you from radiation exposure.
    [Show full text]
  • Experiment "Gamma Dosimetry and Dose Rate Determination" Instruction for Experiment "Gamma Dosimetry and Dose Rate Determination"
    TECHNICAL UNIVERSITY DRESDEN Institute of Power Engineering Training Reactor Reactor Training Course Experiment "Gamma Dosimetry and Dose Rate Determination" Instruction for Experiment "Gamma Dosimetry and Dose Rate Determination" Content: 1 .... Motivation 2..... Theoretical Background 2.1... Properties of Ionising Radiation and Interactions of Gamma Radiation 2.2. Detection of Ionising Radiation 2.3. Quantities and Units of Dosimetry 3..... Procedure of the Experiment 3.1. Commissioning and Calibration of the Dosimeter Thermo FH40G 3.2. Commissioning and Calibration of the Dosimeter Berthold LB 133-1 3.3. Commissioning and Calibration of the Dosimeter STEP RGD 27091 3.4. Setup of the Experiment 3.4.1. Measurement of Dose Rate in Various Distances from the Radiation Source 3.4.2. Measurement of Dose Rate behind Radiation Shielding 3.5. Measurement of Dose Rate at the open Reactor Channel 4..... Evaluation of Measuring Results Figures: Fig. 1: Composition of the attenuation coefficient µ of γ-radiation in lead Fig. 2: Design of an ionisation chamber Fig. 3: Classification and legal limit values of radiation protection areas Fig. 4: Setup of the experiment (issued: January 2019) - 1 - 1. Motivation The experiment aims on familiarising with the methods of calibrating different detectors for determination of the dose and the dose rate. Furthermore, the dose rate and the activity in the vicinity of an enclosed source of ionising radiation (Cs-137) will be determined taking into account the background radiation and the measurement accuracy. Additionally, the experiment focuses on the determination of the dose rate of a shielded source as well as on the calculation of the required thickness of the shielding protection layer for meeting the permissible maximum dose rate.
    [Show full text]
  • Development of Chemical Dosimeters Development Of
    SUDANSUDAN ACADEMYAGADEMY OFOF SCIENCES(SAS)SGIENGES(SAS) ATOMICATOMIC ENERGYEhTERGYRESEARCHESRESEARCHES COORDINATIONCOORDII\rATI ON COUNCILCOUNCIL - Development of Chemical Dosimeters A dissertation Submitted in a partial Fulfillment of the Requirement forfbr Diploma Degree in Nuclear Science (Chemistry) By FareedFadl Alla MersaniMergani SupervisorDr K.S.Adam MurchMarch 2006 J - - - CONTENTS Subject Page -I - DedicationDedication........ ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... I Acknowledgement ... '" ... ... ... ... ... ... '" ... ... ... ... '" ... '" ....... .. 11II Abstract ... ... ... '" ... ... ... '" ... ... ... ... -..... ... ... ... ... ... ..... III -I Ch-lch-1 DosimetryDosimefry - 1-1t-l IntroductionLntroduction . 1I - 1-2t-2 Principle of Dosimetry '" '" . 2 1-3l-3 DosimetryDosimefiySystems . 3J 1-3-1l-3-l primary standard dosimeters '" . 4 - 1-3-2l-3-Z Reference standard dosimeters ... .. " . 4 1-3-3L-3-3 Transfer standard dosimeters ... ... '" . 4 1-3-4t-3-4 Routine dosimeters . 5 1-4I-4 Measurement of absorbed dose . 6 1-5l-5 Calibration of DosimetryDosimetrvsystemsvstem '" . 6 1-6l-6 Transit dose effects . 8 Ch-2ch-2 Requirements of chemical dosimeters 2-12-l Introduction ... ... ... .............................................. 111l 2-2 Developing of chemical dosimeters ... ... .. ....... ... .. ..... 12t2 2-3 Classification of Dosimetry methods.methods .......................... 14l4 2-4 RequirementsRequiremsnts of ideal chemical dosimeters ,. ... 15 2-5 Types of chemical system .
    [Show full text]
  • The International Commission on Radiological Protection: Historical Overview
    Topical report The International Commission on Radiological Protection: Historical overview The ICRP is revising its basic recommendations by Dr H. Smith Within a few weeks of Roentgen's discovery of gamma rays; 1.5 roentgen per working week for radia- X-rays, the potential of the technique for diagnosing tion, affecting only superficial tissues; and 0.03 roentgen fractures became apparent, but acute adverse effects per working week for neutrons. (such as hair loss, erythema, and dermatitis) made hospital personnel aware of the need to avoid over- Recommendations in the 1950s exposure. Similar undesirable acute effects were By then, it was accepted that the roentgen was reported shortly after the discovery of radium and its inappropriate as a measure of exposure. In 1953, the medical applications. Notwithstanding these observa- ICRU recommended that limits of exposure should be tions, protection of staff exposed to X-rays and gamma based on consideration of the energy absorbed in tissues rays from radium was poorly co-ordinated. and introduced the rad (radiation absorbed dose) as a The British X-ray and Radium Protection Committee unit of absorbed dose (that is, energy imparted by radia- and the American Roentgen Ray Society proposed tion to a unit mass of tissue). In 1954, the ICRP general radiation protection recommendations in the introduced the rem (roentgen equivalent man) as a unit early 1920s. In 1925, at the First International Congress of absorbed dose weighted for the way different types of of Radiology, the need for quantifying exposure was radiation distribute energy in tissue (called the dose recognized. As a result, in 1928 the roentgen was equivalent in 1966).
    [Show full text]
  • The Ionising Radiations Regulations 2017
    Title of document 4 ONR GUIDE THE IONISING RADIATIONS REGULATIONS 2017 Document Type: Nuclear Safety Technical Inspection Guide Unique Document ID and NS-INSP-GD-054 Revision 7 Revision No: Date Issued: April 2019 Review Date: April 2022 Professional Lead – Approved by: K McDonald Operational Inspection Record Reference: CM9 Folder 1.1.3.979. (2020/209725) Rev 6: Update to include reference to the Ionising Radiations Regulations 2017 Revision commentary: Rev 7: Updated review period TABLE OF CONTENTS 1. INTRODUCTION ................................................................................................................. 2 2. PURPOSE AND SCOPE ..................................................................................................... 2 3. THE IONISING RADIATIONS REGULATIONS 2017 .......................................................... 2 4. PURPOSE OF THE IONISING RADIATIONS REGULATIONS 2017 ................................. 3 5. GUIDANCE ON ARRANGEMENTS FOR THE IONISING RADIATIONS REGULATIONS 2017 ..................................................................................................................................... 3 6. GUIDANCE ON INSPECTION OF ARRANGEMENTS AND THEIR IMPLEMENTATION.. 5 7. FURTHER READING ........................................................................................................ 16 8. DEFINITIONS .................................................................................................................... 16 9. APPENDICES ...................................................................................................................
    [Show full text]
  • Dosimeter Comparison Chart
    DOSIMETER COMPARISON CHART Instadose®+ Instadose® EPD or APD TLD Dosimeter OSL Dosimeter Dosimeter Dosimeter Dosimeter Cost $ $ $ $$$$ Photon Photon Photon Photon Photon Beta Beta Neutron DEEP - Hp(10) DEEP - Hp(10) Neutron Neutron Measurements SHALLOW - Hp(0.07) SHALLOW - Hp(0.07) DEEP - Hp(10) DEEP - Hp(10) DEEP - Hp(10) SHALLOW - Hp(0.07) SHALLOW - Hp(0.07) SHALLOW - Hp(0.07) EYE - Hp(3) EYE - Hp(3) Read Out Accumulated Accumulated Accumulated Accumulated Accumulated (On-Demand) (On-Demand) (Lab Processing) (Lab Processing) & Dose Rate Unlimited On- Demand Dose Reads Re-Calibration Required Wearer Engagement High High Low Low High Online Management Portal (Website) Provider Dependent NVLAP Highly manual Accreditation process Immediate Online Badge Reassignment Provider Dependent Archiving Dose (Wearer) Meets Legal Highly manual Dose of Record process for meeting Requirements accreditation NO Collection/ Must be collected to Redistribution meet legal dose of Required record requirements Read/View Dose Data on Your Smartphone Automatic (Calendar-set) Dose Reads Wireless Radio Transmission of USB plug-in to PC Dose Data Communication Immediate High Dose Alerts Upon Successful Communication Instadose Dosimeters use direct ion storage (DIS) TLD (Thermoluminescent OSL (Optically EPDs (Electronic Descriptions technology to measure ionizing radiation through Dosimeter) measures Stimulated Personal Dosimeter) interactions that take place between the non- ionizing radiation Luminescence or APDs (Active volatile analog memory cell, which is surrounded exposure by assessing Dosimeter) measures Personal Dosimeter) by a gas filled ion chamber with a floating gate the intensity of visible ionizing radiation makes use of a diode that creates an electric charge enabling ionized light emitted by a crystal exposure when radiation (silicon or PIN, etc.) to particles to be measured by the change in the inside the detector when energy deposited in the detect “charges” induced electric charge created.
    [Show full text]
  • Site-Specific Calibration of the Hanford Personnel Neutron Dosimeter
    Gw^HI0n--7 PNL-SA-24010 SITE-SPECIFIC CALIBRATION OF THE HANFORD PERSONNEL NEUTRON DOSIMETER BEC 2 7 mm A. W. Endres Q o 7- L. W. Brackenbush ° f W. V. Baumgartner B. A. Rathbone October 1994 Presented at the Fourth Conference on Radiation Protection and Dosimetry October 23-27, 1994 Orlando, Florida Prepared for the U.S. Department of Energy under Contract DE-AC06-76RLO 1830 Pacific Northwest Laboratory Richland, Washington 99352 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsi• bility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Refer• ence herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recom• mendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. MUM1TED 4STR1BUTION Or TH« DU^- to u G£ DISCLAIMER Portions of this document may be illegible in electronic image products. Images are produced from the best available original document. SITE-SPECIFIC CALIBRATION OF THE HANFORD PERSONNEL NEUTRON DOSIMETER A. W. Endres, L. W. Brackenbush, W. V. Baumgartner, and B. A. Rathbone Pacific Northwest Laboratory, Richland, Washington 99352 INTRODUCTION A new personnel dosimetry system, employing a standard Hanford thermo• luminescent dosimeter (TLD) and a combination dosimeter with both CR-39 nuclear track and TLD-albedo elements, is being implemented at Hanford.
    [Show full text]
  • New Techniques of Low Level Environmental Radiation Monitoring at Jlab
    Abstract #188 - ANIMMA International Conference, 7-10 June 2009, Marseille, France 1 New Techniques of Low Level Environmental Radiation Monitoring at JLab Pavel Degtiarenko and Vladimir Popov, Thomas Jefferson National Accelerator Facility contribution of operational gamma dose was evaluated Abstract—We present the first long-term environmental indirectly during special measurements. Direct continuous radiation monitoring results obtained using the technique of pulse measurements and long-term monitoring of operational gamma mode readout for the industry-standard Reuter-Stokes RSS-1013 dose rates at needed levels of sensitivity and stability were argon-filled high pressure ionization chambers (HPIC). With novel designs for the front-end electronics readout and impractical due to cost and complexity of available solutions. customized signal processing algorithms, we are capable of Recently developed pulse-mode readout electronics for detecting individual events of gas ionization in the HPIC, caused Ionization Chambers [1] allowed us to successfully make these by interactions of gammas and charged particles in the gas. The measurements. HPIC hardware may be characterized as one of technique provides enough spectroscopic information to the most stable and reliable types of ionizing radiation distinguish between several different types of environmental and detectors. The number of ion pairs produced by a radiation man-made radiation. The technique also achieves a high degree of sensitivity and stability of the data, allowing long-term field in the fixed amount of gas filling the HPIC is independent environmental radiation monitoring with unprecedented of temperature and other environmental parameters. Ultimately precision. reliable and stable charge collection and measurement in the Index Terms—Environmental radiation monitoring, ionization low-level radiation fields may be achieved by using the pulse- chambers, noise measurement, radiation detection circuits, signal mode operation of the readout electronics.
    [Show full text]
  • An Overview of NCRP Commentary No. 19 Objectives of This Presentation
    Key Elements of Preparing Emergency Responders for Nuclear and Radiological Terrorism An Overview of NCRP Commentary No. 19 Objectives of this Presentation • Provide an overview of the Commentary to allow audiences to become familiar with the material. • Focus on key points discussed in the Commentary. • Provide additional explanations for the recommendations. Background • Commentary was prepared at the request of the Department of Homeland Security (DHS). • Recommendations are intended for DHS and state and local authorities who prepare emergency responders for terrorist incidents involving radiation or radioactive materials. Background • Commentary builds on previous NCRP reports – NCRP Report No. 65, Management of Persons Accidentally Contaminated with Radionuclides (1980). – NCRP Report No. 138, Management of Terrorist Events Involving Radioactive Material (2001). Background • Commentary No. 19 is limited to the key elements of preparing emergency responders for nuclear and radiological terrorism. • Details of implementation are left to the DHS in concert with state and local authorities. Serving on the NCRP Scientific Committee SC 2-1 that prepared this Commentary were: John W. Poston, Sr., Chairman Texas A&M University, College Station, Texas Steven M. Becker Brian Dodd The University of Alabama at Birmingham BDConsulting School of Public Health Las Vegas, Nevada Birmingham, Alabama John R. Frazier Brooke Buddemeier Auxier & Associates, Inc. Department of Homeland Security Knoxville, Tennessee Washington, D.C. Fun H. Fong, Jr. Jerrold T. Bushberg Centers for Disease Control and Prevention University of California, Davis Atlanta, Georgia Sacramento, California Ronald E. Goans John J. Cardarelli MJW Corporation Environmental Protection Agency Clinton, Tennessee Cincinnati, Ohio Ian S. Hamilton W. Craig Conklin Baylor College of Medicine Department of Homeland Security Houston, Texas Washington, D.C.
    [Show full text]
  • Radiation Glossary
    Radiation Glossary Activity The rate of disintegration (transformation) or decay of radioactive material. The units of activity are Curie (Ci) and the Becquerel (Bq). Agreement State Any state with which the U.S. Nuclear Regulatory Commission has entered into an effective agreement under subsection 274b. of the Atomic Energy Act of 1954, as amended. Under the agreement, the state regulates the use of by-product, source, and small quantities of special nuclear material within said state. Airborne Radioactive Material Radioactive material dispersed in the air in the form of dusts, fumes, particulates, mists, vapors, or gases. ALARA Acronym for "As Low As Reasonably Achievable". Making every reasonable effort to maintain exposures to ionizing radiation as far below the dose limits as practical, consistent with the purpose for which the licensed activity is undertaken. It takes into account the state of technology, the economics of improvements in relation to state of technology, the economics of improvements in relation to benefits to the public health and safety, societal and socioeconomic considerations, and in relation to utilization of radioactive materials and licensed materials in the public interest. Alpha Particle A positively charged particle ejected spontaneously from the nuclei of some radioactive elements. It is identical to a helium nucleus, with a mass number of 4 and a charge of +2. Annual Limit on Intake (ALI) Annual intake of a given radionuclide by "Reference Man" which would result in either a committed effective dose equivalent of 5 rems or a committed dose equivalent of 50 rems to an organ or tissue. Attenuation The process by which radiation is reduced in intensity when passing through some material.
    [Show full text]
  • External and Internal Dosimetry
    Chapter 7 External and Internal Dosimetry H-117 – Introductory Health Physics Slide 1 Objectives ¾ Discuss factors influencing external and internal doses ¾ Define terms used in external dosimetry ¾ Discuss external dosimeters such as TLDs, film badges, OSL dosimeters, pocket chambers, and electronic dosimetry H-117 – Introductory Health Physics Slide 2 Objectives ¾ Define terms used in internal dosimetry ¾ Discuss dose units and limits ¾ Define the ALI, DAC and DAC-hr ¾ Discuss radiation signs and postings H-117 – Introductory Health Physics Slide 3 Objectives ¾ Discuss types of bioassays ¾ Describe internal dose measuring equipment and facilities ¾ Discuss principles of internal dose calculation and work sample problems H-117 – Introductory Health Physics Slide 4 External Dosimetry H-117 – Introductory Health Physics Slide 5 External Dosimetry Gamma, beta or neutron radiation emitted by radioactive material outside the body irradiates the skin, lens of the eye, extremities & the whole body (i.e. internal organs) H-117 – Introductory Health Physics Slide 6 External Dosimetry (cont.) ¾ Alpha particles cannot penetrate the dead layer of skin (0.007 cm) ¾ Beta particles are primarily a skin hazard. However, energetic betas can penetrate the lens of an eye (0.3 cm) and deeper tissue (1 cm) ¾ Beta sources can produce more penetrating radiation through bremsstrahlung ¾ Primary sources of external exposure are photons and neutrons ¾ External dose must be measured by means of appropriate dosimeters H-117 – Introductory Health Physics Slide 7
    [Show full text]