Ventilation Product catalogue 2019 for professionals

Including new Modular L Fresh air for the residential and commercial sector Heat reclaim ventilation and air handling applications MODULAR L (SMART)

D-AHU MODULAR R

2 INTRO

Table of contents

The widest ventilation range on the market 4

ERV / HRV - Heat reclaim ventilation units 9

››Modular L Smart (ALB-RBS/LBS) NEW ››VAM-FC/J / VKM-GB(M)

Condensing units for AHU 29

Options & accessories 42

Tools and platforms 49

Technical drawings 57

3 ARGUE CARDS

5 reasons why Daikin’s ventilation range is unique in the market

1 Market leading controls & connectivity

›› Interlock of ventilation and system • Control ERV/HRV and air conditioning from the same controller • Aligns the operation mode between the systems to save energy ›› Easy integration in the total solution • Online control and monitoring via the Daikin Cloud • Full portfolio integration in the intelligent Touch Manager, Daikins cost-effective mini BMS ›› User-friendly controller with premium design • Intuitive touch button control

21°C

2 Unique installation benefits

›› Integrates seamlessly in the Daikin total solution, ensuring a single point of contact ›› Total fresh air solution with Daikin supplying both the VAM/Modular L Smart and the electrical heater ›› Daikin AHU and condensing unit connect Plug & Play thanks to same pipe diameters, factory mounted controls, expansion valves, etc.

4 INTRO

3 High energy efficiency Up to ›› Energy recovery of up to 92%, reducing running costs ›› Free nighttime cooling using fresh outside air 92% ›› Inverter driven centrifugal fans heat recovery ›› ErP compliant

4 Best comfort

›› Wide range of units to control fresh air and

›› Wide range of optional filters to suit the application available up to ePM1 80% (F9) ›› Special recovers heat and moisture from outgoing air to warm up and humidify incoming air to comfortable levels (VAM, VKM)

5 Top reliability

›› Most extensive testing before new units leave the factory ErP ›› Widest support network and after sales service COMPLIANT ›› All spare parts available in Europe

COGNITIVE FUNCTION SCORES … Did you know?

CO2 levels and ventilation rates all have significant, independent impacts on cognitive function: + 61% + 101% IN GREEN BUILDING IN ENHANCED CONDITIONS GREEN BUILDING CONDITIONS

5 Widest range of DX integrated ventilation on the market

Daikin offers a variety of solutions from small heat recovery ventilation to large-scale air handling units for the provision of fresh air ventilation to homes, or commercial premises.

Ventilation solutions

Daikin offers state-of-the-art ventilation solutions that can easily be integrated into any project: ›› Unique portfolio within DX manufacturers ›› High-quality solutions complying with the highest Daikin quality standards ›› Seamless integration of all products to provide the best indoor climate ›› All Daikin products connected to a single controller for complete control of the HVAC system.

Heat Reclaim Ventilation - Ventilation with heat recovery as standard

Our heat recovery units recover (Modular L / Modular L Smart) and (VAM/VKM), substantially reducing the load on the air conditioning system up to 40%.

Ventilation with DX connection - Control over fresh air temperature

Daikin offers a range of inverter condensing units to be used in combination with Daikin AHUs for ultimate control over the fresh air. There are 4 control possibilities when combining AHU and Daikin outdoor units hence offering all the required flexibility for any installation. Indoor units can be combined to the same outdoor unit to reduce the installation costs. For false-ceiling installations where space is a constraint, the VKM can fit perfectly to deliver fresh air at a comfortable temperature and it has an optional humidification element.

6 INTRO

Five components of Ventilation ›› Ventilation: Ensures the provision of fresh air ›› Energy recovery: Delivers energy savings by transferring heat and Energy moisture between airflows Humidification recovery ›› Air processing: Delivers the right supply temperature to decrease the indoor unit load ›› Humidification: Ensures relative indoor humidity levels are respected ›› Filtration: Separates pollen, and pollution odours that are harmful Air Filtration to individuals’ health processing

Fresh air portfolio

150 500 1,000 2,000 2,500 3,000 3,500 15,000 25,000 140,000 [m3/h]

›› High efficiency counterflow heat exchanger ›› Free-cooling operation NEW ›› EC centrifugal ›› Wide range of options D-AHU MODULAR L (SMART) ›› Smart version connects Plug & Play to Sky Air / VRV systems ›› Compact size ›› High energy efficient paper recovering sensible and latent heat ›› EC fan motors ›› Filter clogging alarm based on pressure VAM-FC / VAM-J

Decentralised systems Decentralised ›› With DX coil for temperature control ›› Increased comfort ›› option VKM-GB(M) ›› High efficiency aluminium plate heat exchanger ›› Pre-configured sizes ›› Plug & Play pre-configured controls ›› With DX or water coil option D-AHU MODULAR P

›› Rotary heat exchanger (sorption and sensible technology) ›› Pre-configured sizes ›› Plug & Play pre-configured controls ›› With DX or water coil option D-AHU MODULAR R

›› Fully customizable

Centralised systems Centralised ›› Plug & play ›› 4 types of control ›› With DX or water coil option D-AHU Professional

7 Direct integration into the Sky Air or VRV control solution › Saves up to 40% in running costs › Unified control point for the complete air conditioning and ventilation installation

Wide range of decentralised ERV/HRV units to suit the building needs

8 Energy / Heat Reclaim Ventilation ERV/HRV BENEFITS ERV/HRV Ventilation Interlocked with air conditioning system

Premium efficiency heat recovery unit NEW Modular L (Smart) (ALB-(RBS/LBS)) 17 ›› Heat recovery unit ›› Counter flow plate heat exchanger ›› ESP up to 600 Pa ›› Operates as stand-alone or combined with Sky Air or VRV systems

Heat reclaim ventilation (VAM-FC/J) 22

›› Heat and moisture recovery ›› Achieve with fresh outdoor air ›› Operates as stand-alone or combined with Sky Air or VRV systems

Heat reclaim ventilation with humidification and air processing (VKM-GB(M)) 22

›› Heat and moisture recovery ›› Humidification and air processing (preconditioning) of fresh air ›› Achieve free cooling with fresh outdoor air ›› Plug & Play piping and wiring connection with Daikin VRV unit(s)

9 Benefits of Daikin ERV/HRV systems

10 1 Market leading controls & connectivity

Interlock of the ventilation operation with the air conditioner operation

Interlock of the ventilation operation with functions. By incorporating a variety of centralised the air conditioner operation greatly simplifies control equipments, the user can build a large, overall system control. The same remote controller high grade centralised control system. centralises air conditioning and ventilation ERV/HRV BENEFITS ERV/HRV

VRV or Sky Air indoor unit

INTERLOCKING

User-friendly wired remote contoller with premium design

White Silver Black

BRC1H519W/S/K ›› Sleek and elegant design ›› Intuitive touch button control ›› 3 color versions ›› Advanced settings and monitoring can be easily done via your smartphone Advanced user settings Field settings ›› Flat back for easy wall installation ›› Compact to fit standard size socket boxes

One Plug & Play - integrated ventilation Stop Shop

›› One-stop shop for all system components, which results in streamlined design and business solutions. ›› Efficient project follow-up, installation and subsequent commissioning and maintenance. ›› Ventilation easily interlocked to air conditioner operation thanks to simplified system control. 22 + + + +

11 2 Easy and flexible installation

High Static Pressure

External static pressure (ESP) up to 600 Pa (ALB) facilitates the use with flexible ducts of varying lengths.

Automatic Airflow External static pr essure (Pa) Adjustment function

Automatically selects the most appropriate fan curve to achieve the Fan characteristic units’ nominal air flow within ±10% curves

Why?

After installation the real ducting will frequently differ from the ini- tially calculated air flow resistance  the real air flow may be much lower or higher than designed.

Duct resistance Automatic Airflow Adjustment function will adapt the unit’s fan matic adjustment ) speed to any ducting automatically (45 fan curves are ­available on curves every model (ALB/VAM)), making installation much faster.

± /min)

Wide operation range ALB VAM VKM 50° The ERV/HRV unit can be installed practically 45°CDB 46°CDB 40°CDB anywhere. The standard operation range (outdoor temperature) 40° is from -15°C to 40°CDB for VKM units, from -10ºC (+5ºC in case of upside-down installation) to 46ºCDB 30° for VAM units, and can be extended down if a Daikin preheater is installed. 20° 1 Contact your local dealer for more information and restrictions 10°

0° -5° CDB -10° -10° CDB -15°

preheater CDB with with -20° with optional optional optional preheater preheater … … …

Optional pre-heater Optional pre-heater for VAM for Modular L Smart

12 Flexible installation

280mm Slim Design

At just 280 mm high, the slim design of ALB02* the HRV unit enables it to be mounted in narrow ceiling cavities and irregularly shaped spaces

ERV/HRV model: AHU ON Standard air Flexible handling unit: ERV/HRV BENEFITS ERV/HRV ON Compared to a standard air handling unit, CENTRAL CONTROL the HRV models provide much greater flexibility INDIVIDUAL to match the actual building use, in case of a multi- ERV/HRV CONTROL tenant installation. Additionally, the renovation of a OFF building can be carried out in phases.

GREATER ERV/HRV FLEXIBILITY ON

“Super Wiring” System

A Super Wiring system is used to enable the shared system with a centralised remote control, simply by use of wiring between indoor units, outdoor units connecting it to the outdoor units. Thanks to a non and the centralised remote control. This system polarity wiring system, incorrect connections become makes it easy for the user to retrofit the existing impossible and installation time is reduced.

Indoor unit

ALB-RBS/LBS VAM/VKM Wired remote control Outdoor unit

Connection to field-supplied booster fan increases flexibility even more

›› Longer ducting or use of central possible ›› Lower cost by using the booster fan instead of ›› Overcomes actual field situation when ducting is replacing with a larger unit when the ESP is not different from calculation matched

Example when HRV ESP is not high enough or field situation differs from calculation

No booster fan with booster fan

HRV HRV Comfort Comfort Discomfort Comfort Comfort Comfort

13 3 High efficiency

Energy saving ventilation via heat recovery of both heat and humidity

Daikin’s ERV/HRV solutions prevent energy being wasted by recovering up to 92% waste heat from Recovers up to the outgoing air instead of simply expelling the heat, 92% offering high energy efficiency. of wasted heat ALB-RBS/LBS

Reduce the load on the air conditioning system by up to 40%

›› 24% by using heat recovery ventilation (in comparison with normal ventilation fans) ›› 6% by switching over to auto-ventilation mode ›› 2% by using the pre-cool, pre-heat control (reduces air conditioning load by running the HRV unit after the air conditioning is switched on) ›› 5% by enabling the free cooling operation overnight

›› 3% by preventing over-ventilation with the optional CO2 sensor

Different operation modes of ERV/HRV units

Heat exchange mode Bypass mode Heat exchanger element Exhaust fan (heat recovery)

EA RA EA RA

Automatic changeover OA SA OA SA

Air supply fan

EA: Exhaust air RA: Return air (from room) OA: Outdoor air SA: Supply air (to room)

14 Heat reclaim ventilation Nighttime free cooling

Nighttime free cooling operation is an energy saving free cooling reduces the cooling load when function operating at night when the air conditioning air conditioning is switched on in the morning, is switched off. By ventilating rooms containing office reducing the daily running costs. equipment that increases ,

The VAM and Modular L Smart can also perform nighttime free cooling in stand alone operation. The set temperature is a field setting at installation.

+ OFF OFF OFF + BENEFITS ERV/HRV Free A/C Ventilation Only ventilation A/C Ventilation 40°C cooling

Set T° 30°C Indoor temperature Outdoor temperature

20°C

… 5 PM 9 AM …

Prevent energy losses from over-ventilation with CO2 sensor

Enough fresh air is needed to create an enjoyable installed which switches off the ventilation environment, but ventilating constantly is leading to system when there is enough fresh air in the room,

energy waste. Therefore an optional CO2 sensor can be thus saving energy.

CO level Example of CO2 sensor operation in a meeting room: 2 Fixed ventilation rate 9 AM 12 PM 5 PM Ventilation amount

Decrease in air volume and more energy saving compared to fixed ventilation rate

Increase in air volume and better comfort When many people are in the room, compared to fixed more fresh air is brought in to maintain ventilation rate comfortable CO2 levels. When fewer people are in the room, energy is saved by bringing in less fresh air.

7 8 9 10 11 12 13 14 15 16 17 18 19 hour

Morning meeting Lunch time Meeting

Up to 75% less energy consumed for ventilation in Herten building

A two-year test at a ‘netZero Energy Building’ in Herten has revealed that a huge energy saving is

possible by using CO2 sensors in conjunction with the Daikin VAM systems.

15 4 Best Comfort • High quality indoor air • Whisper quiet

Optional medium and fine dust filters available The optional filter comply with ISO 16890

Optional filters up to ePM1 70% (F8, VAM) and ePM1 80% (F9, ALB) are available to meet your customer request or the local legislation.

Can operate in over and underpressure to prevent unpleasant odours

The user can select 2 fresh-up modes via the remote control for a more comfortable air environment.

1. Supply rich mode (overpressure): 2. Exhaust fresh-up (underpressure):

A higher air supply than air exhaust maintains proper A higher exhaust air than air supply decreases room room pressure to prevent back-flow of toilet/kitchen pressure to prevent the leaking of odours or floating odours or moisture inflow. into other rooms.

Portion of fresh-up Air exhaust HRV operation HRV Normal Hall way Air supply Air exhaust ventilation fan

70% 30% Sick room Portion of Air supply 70% 100% exhaust 100% operation

30% Relative humidity (%) eg. Office eg. Hospital

Preventing that toilet odours flow to the office No bacteria can flow from the sick room to the hall way

Low operation sound level

Continuous research by Daikin into reducing operation sound levels has resulted in sound pressure levels down to 20.5dBA (VAM150). DBA PERCEIVED LOUDNESS SOUND 0 Treshold of hearing - 20 Extremely soft Rustling leaves

Daikin ERV/HRV unit 40 Very soft Quiet room 60 Moderately loud Normal conversation

80 Very loud City traffic noise

100 Extremely loud Symphonic orchestra

120 Threshold of feeling pain Jet taking off

16 Modular L Smart Premium Efficiency Heat Recovery Unit

The optional filter comply with ISO 16890

NEW Ventilation

Energy Humidification recovery

Air SMART L MODULAR Filtration processing

ALB-RBS/LBS

Highlights Heat exchanger

›› Connects Plug&Play into the Sky Air and VRV ›› Premium quality counter flow plate control network heat exchanger ›› Easy installation and commissioning ›› Up to 92% of the thermal energy recovered

›› Internal pre-filter stage (up to ePM1 50% (F7) ›› High grade aluminum allowing optimum

+ ePM1 80% (F9)) making the unit reach highest corrosion protection indoor air quality requirements. ›› Wide air flow coverage from 150m3/h to 3,450m3/h ›› Exceeding ERP 2018 requirements ›› Best choice when compactness is needed (only 280 mm height up to 550 m3/h) ›› 50 mm double skin panel (120 kg/m3) for a maximum sound and

EC

›› Maximum ESP available 600 Pa (depending on model sizes and airflow) ›› Inverter driven with IE4 premium efficiency motor ›› High-efficient blade profiling ErP ›› Reduced energy consumption COMPLIANT ›› Optimized SFP (Specific Fan Power) for an efficient unit operation

17 Premium quality to meet most sophisticated needs

Heat exchanger

› Premium quality counterflow plate heat exchanger › Up to 92% of the thermal energy recovered › High grade aluminium that allows best corrosion protection › Completely joint sealing › No screws or rivets in any part

Filters

› Easy replaceable compact filters with large surface area, which can be removed from bottom access

› Up to ePM1 50% (F7) + ePM1 80% (F9) filtration efficiency › No tools are needed to change the filters

› Fresh air filters* (ePM1 50% (F7) efficiency as standard)

› Return filters* (ePM10 75% (M5) efficiency as standard)

*Optional additional filter and pre-filter stage coarse 55% (G4),

ePM10 75% (M5), ePM1 50% (F7), ePM1 80% (F9)

Supply/Return fan

› Fan/motor combination with very low noise level › Reduced energy consumption › Inverter driven with IE4 motor efficiency › Infinitely variable speed › Ultra-efficient blade profiling › Maintenance-free ball bearings › No screws or rivets in any part

18 MODULAR L SMART L MODULAR

Rectangular duct flange

The standard dimensions are:

› 250x150 (Size 2) › 400x200 (Size 3) › 500x300 (Size 4/5) › 700x400 (Size 6/7)

› Optional rectangular to circular transition Bypass damper Unit structure › 100% automatic bypass damper with › External pre – painted metal sheet proportional opening for and free › Internal Aluzinc cooling operation › 50 mm Double skin panel thickness › Mineral wool insulated › Great sound absorption and low noise Fully integratable in the DIII › Hinged or fully removable bottom doors make the unit easy accessible for service and maintenance network (Sky Air and VRV) › Unit is accessible from bottom panels › Best choice when compactness is needed (only 280 mm height for up to 550 m3/h of air flow)

19 Technical details

Control logic

› Air quality analysis with the capability of monitoring and control of the actual level of CO2 through optional sensor (accessory) › Full automatic bypass to manage free cooling › Filter alarm in accordance with the EU Reg 1253 › DIII-net integration through Daikin building air conditioning control systems (D-BACS) › BMS integration through dedicated interfaces (Modbus, BACnet)

Air flow range

Modular L Smart is available in 6 sizes covering a wide range of applications such as hotels, offices, schools and light commercial buildings

Size 3000

2300 Size 7

1500 Size 6

1200 Size 5

600 Size 4

300 Size 3

Size 2

500 1500 2500 3500 1000 2000 3000 Airflow rate (m3/h) Max airflow calculated @100Pa of external static pressure (ESP) From 150 up to 3450 m3/h Nominal airflow 3m /h

20 Return Air Fresh Air Fresh Air Return Air MODULAR L SMART L MODULAR Supply Air Exhaust Air Exhaust Air Supply Air

Right drain connection (ALB-RBS) Left drain connection (ALB-LBS)

Technical details

D-AHU Modular L Smart ALB-RBS/LBS 02 03 04 05 06 07 Airflow m3/h 300 600 1200 1500 2300 3000 Heat exchanger thermal efficiency1 % 90 91 90 90 92 91 External static pressure Nom. Pa 100 100 100 100 100 100 Temperature after heat exchanger1 Nom. °C 19,4 19,5 19,4 19,2 19,8 19,5 Max ESP @ nom. airflow Pa 400 450 260 270 250 210 Current Nom. A 0,52 1,17 1,91 2,48 3,76 5,39 Power input Nom. kW 0,12 0,27 0,44 0,57 0,87 1,24 SFPv2 kW/m3/s 1,24 1,49 1,28 1,32 1,32 1,46 ERP compliant ErP 2018 Compliant Electrical supply Phase ph 1 1 1 1 1 1 Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 Voltage V 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac Main unit dimensions Width mm 920 1100 1600 1600 2000 2000 Height mm 280 350 415 415 500 500 Length mm 1660 1800 2000 2000 2000 2000 Rectangular duct flange Width mm 250 400 500 500 700 700 Height mm 150 200 300 300 400 400 Unit Sound Power Level (Lwa) dB 48 54 57 53 60 57 Unit Sound Pressure Level3 dBA 34 39 41 37 44 41 Weight unit kg 125 180 270 280 355 360

1. Winter design condition: Outdoor: -5°C, 90% Indoor: 22°C,50% 2. SFPv is a parameter that quantifies the fan efficiency (the lower it is the better will be). This reduces if airflow decreases. 3. According to EN3744. Surrounding, Directivity (Q) = 2, @ 1,5m distance

21 ERV energy reclaim ventilation

Heat reclaim ventilation, air processing and humidification

Ventilation Ventilation

Energy Energy Humidification Humidification recovery recovery

Air Air Filtration Filtration processing processing

VAM-FC / VAM-J VKM-GB(M)

High efficiency Maximum flexibility

›› Energy saving ventilation via recovery of ›› Plug & Play - integrated ventilation both heat and humidity ›› Flexible installation ›› Reduce the load on the air conditioning system by ›› Wide range of units up to 40% ›› High static pressure ›› Nighttime free cooling ›› Wide operation range ›› Prevent energy losses from over-ventilation with ›› Connection to field-supplied booster fan

CO2 sensor increases flexibility even more (VAM-FC/J only) ›› No drain needed (VAM-FC/J only)

High indoor air quality & whisper quiet operation

›› Optional medium and fine dust filters (VAM-FC/J only) ›› Can operate in over and underpressure to prevent unpleasant odours ›› Low operation sound level

22 ERV energy reclaim ventilation Energy saving ventilation via enthalpy recovery of both heat and humidity

Daikin’s ERV solutions prevent energy being wasted Specially developed heat exchange element by recovering up to 85% waste heat from the Recovers up to outgoing air instead of simply expelling the heat, The heat exchange element rapidly recovers heat 85% offering high energy efficiency. contained in latent heat (vapour). of waste heat

Outdoor Indoor SA Operation of the high 30.6°C 27.4°C Temperature efficiency paper. SA 62% RH 63% RH and humidity

are exhanged Cross flow of air to between the exchange heat and layers RA moisture. 32°C RA 70% RH 26°C VAM/VKM 50% RH Integrally-formed liner

RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room) High indoor comfort

Thanks to the heat and moisture exchange the hot and humid outside air is brought to levels close to indoor conditions saving on the air conditioning running cost and maintaining comfort.

Can be installed Horizontal installation Vertical installation

horizontally, upside down Ceiling Ceiling or vertically False ceiling Access The VAM models do not require a drain, giving hatch greater flexibility for the installation of the units.

In case of upside down or vertical installation the Switch box minimum outside temperature is +5°C instead of -10°C.

Access hatch Maintenance cover

23 Creating a high quality environment

Maintain a comfortable indoor environment without fluctuations in room temperature.

How do the ERV units work?

In heating In cooling

Heat recovery Heat recovery + + Heating Cooling 100 80 60 + 100 80 Humidifying 60 Outdoor air temperature Effect of full heat exchange in summer Effect of cooling 1 40

40 2

Indoor temperature during cooling

Effect of 20 Indoor temperature during heating humidification 3 20

2 Outdoor air 1 Effect of temperature in winter heating Effect of full heat exchange Relative humidity (%) -5 0 5 10 15 20 25 30 35 40 -5 0 5 10 15 20 25 30 35 40

Dry bulb temperature (°CDB) Dry bulb temperature (°CDB)

In heating we bring in cold outdoor fresh air and want to avoid cold draught In cooling we bring in hot outdoor fresh air and want to prevent additional load on and dry air. the air conditioning system and too hot indoor temperatures.

1. Cold outside air is crossed with hot inside air. 1. Hot outside air is crossed with cold inside air. In the example the incoming air is heated up from 0 to 16°CDB while keeping In the example the incoming air is cooled down from 34 to 27°CDB while keeping the same relative humidity. This is the effect of the heat and moisture exchange. the same relative humidity. This is the effect of the heat and moisture exchange.

2. The DX coil further cools down the air to prevent hot indoor temperatures and reduce 2. The DX coil further heats up the air to prevent cold draught. In the example the the load on the air conditioning system. incoming air is further heated from 16 to 34°CDB. Because the air is heated up the relative humidity decreases. In the example the incoming air is further cooled down from 27 to 20°CDB.

3. To counter negative effects of dry air the air passes the humidifier which adds moisture in case needed. 3. No humidification is needed in cooling as the air is not dried out In the example the relative humidity rises from 22 to a comfortable 42%.

The result is incoming fresh air with the same humidity and slightly higher The result is incoming fresh air with a slightly lower temperature for perfect comfort. temperature for perfect comfort.

24 Humidification

Operation example: humidification & air processing (heating mode)1 VAM/VKM Heat Exchanger Exhaust Fan Damper Motor DX coil (Direct expansion coil) Elements EA Damper (Exhaust air to outdoors)

OA (Fresh air from outdoors)

RA (Return air from room)

Air Supply Fan SA (Supply air to room)

Electronics Box (Control box)

Float switch Solenoid Humidifier element: valve Utilizing the principle of capillary action, water is permeated throughout the humidifier element. The heated air from the DX coil passes through the water humidifier and absorbs the moisture. SA AIRFLOW

Drain pan Drain

1 VKM-GM example

25 VAM-FC/VAM-J New diamond Energy reclaim ventilation Return air shape heat

Supply air exchanger! Ventilation with heat recovery as standard

›› NEW Thinnest High Efficiency Enthalpy Heat Exchanger in the market (J-series) ›› Energy saving ventilation using indoor heating, cooling and moisture recovery ›› Free cooling possible when outdoor temperature is below indoor Exhaust air temperature (eg. during nighttime) ›› Prevent energy losses from over-ventilation while improving Fresh air

indoor air quality with optional CO2 sensor ›› NEW Possibility to change ESP via wired remote control allows optimisation of the supply air volume (J - series) ›› Can be used as stand alone or integrated in the Sky Air or VRV system ›› Wide range of units: air flow rate from 150 up to 2,000 m³/h High efficiency filters available:

›› Shorter installation time thanks to easy adjustment of nominal air ePM10 70% (M6), ePM1 55% (F7) and ePM1 70% (F8) flow rate, so less need for dampers compared with traditional installation ›› No drain piping needed ›› Can operate in over- and under pressure ›› Total solution for fresh air with Daikin supply of both VAM / VKM and electrical heaters ErP COMPLIANT

Ventilation VAM/VAM 150FC 250FC 350J 500J 650J 800J 1000J 1500J 2000J Power input - 50Hz Heat Nom. Ultra high/High/Low kW 0.132/0.111/ 0.161/0.079/ 0.097 /0.070 / 0.164 /0.113 / 0.247 /0.173 / 0.303 /0.212 / 0.416 /0.307 / 0.548 /0.384 / 0.833 /0.614 / exchange mode 0.058 0.064 0.039 0.054 0.081 0.103 0.137 0.191 0.273 Bypass mode Nom. Ultra high/High/Low kW 0.132/0.111/ 0.161/0.079/ 0.085 /0.061 / 0.148 /0.100 / 0.195 /0.131 / 0.289 /0.194 / 0.417 /0.300 / 0.525 /0.350 / 0.835 /0.600 / 0.058 0.064 0.031 0.045 0.059 0.086 0.119 0.156 0.239 Temperature Ultra high/High/Low % 77.0 (1) / 72.0 (2)/ 74.9 (1) / 69.5 (2)/ 85.1 /86.7 / 80.0 /82.5 / 84.3 /86.4 / 82.5 /84.2 / 79.6 /81.8 / 83.2 /84.8 / 79.6 /81.8 / exchange 78.3 (1) / 72.3 (2)/ 76.0 (1) / 70.0 (2)/ 90.1 87.6 90.5 87.7 86.1 88.1 86.1 efficiency - 50Hz 82.8 (1) / 73.2 (2) 80.1 (1) / 72.0 (2) Enthalpy exchange Cooling Ultra high/High/Low % 60.3 (1)/61.9 (1)/ 60.3 (1)/61.2 (1)/ 65.2 /67.9/ 59.2 /61.8 / 59.2 /63.8 / 67.7 /70.7 / 62.6 /66.4 / 68.9 /71.8 / 62.6 /66.4 / efficiency - 50Hz 67.3 (1) 64.5 (1) 74.6 69.5 73.1 76.8 74.0 77.5 74.0 Heating Ultra high/High/Low % 66.6 (1)/67.9 (1)/ 66.6 (1)/67.4 (1)/ 75.5 /77.6 / 69.0 /72.2 / 73.1 /76.3 / 72.8 /75.3 / 68.6 /71.7 / 73.8 /76.1 / 68.6 /71.7 / 72.4 (1) 70.7 (1) 82.0 78.7 82.7 80.2 77.9 80.8 77.9 Operation mode Heat exchange mode, bypass mode, fresh-up mode Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange Heat exchange element Specially processed non-flammable paper Dimensions Unit HeightxWidthxDepth mm 285x776x525 301x1,113x886 368x1,354x920 368x1,354x1,172 731x1,354x1,172 Weight Unit kg 24.0 46.5 61.5 79.0 157 Casing Material Galvanised steel plate Fan Air flow Heat Ultra high/High/ m³/h 350 (1)/ 500 (1)/ 650 (1)/ 800 (1)/ 1,000 (1)/ 1,500 (1)/ 2,000 (1)/ exchange Low 150 /140 /105 250 /230 /155 300 (1)/ 425 (1)/ 550 (1)/ 680 (1)/ 850 (1)/ 1,275 (1)/ 1,700 (1)/ rate - mode 200 (1) 275 (1) 350 (1) 440 (1) 550 (1) 825 (1) 1,100 (1) 50Hz Bypass mode Ultra high/High/ m³/h 350 (1)/ 500 (1)/ 650 (1)/ 800 (1)/ 1,000 (1)/ 1,500 (1)/ 2,000 (1)/ Low 150 /140 /105 250 /230 /155 300 (1)/ 425 (1)/ 550 (1)/ 680 (1)/ 850 (1)/ 1,275 (1)/ 1,700 (1)/ 200 (1) 275 (1) 350 (1) 440 (1) 550 (1) 825 (1) 1,100 (1) External static Ultra high/High/Low Pa 90 /87/40 70 /63/25 90 (1)/70.0 /50.0 (1) pressure - 50Hz Air filter Type Multidirectional fibrous fleeces Multidirectional fibrous fleeces (G3) Sound pressure Heat Ultra high/High/Low dBA 34.5 (1)/ 37.5 (1)/ 39.0 (1)/ 39.0 (1)/ 42.0 (1)/ 42.0 (1)/ 45.0 (1)/ exchange 27.0 /26.0 28.0 /26.0 32.0 (1)/ 35.0 (1)/ 36.0 (1)/ 36.0 (1)/ 38.5 (1)/ 39.0 (1)/ 41.5 (1)/ level - 50Hz mode /20.5 /21.0 29.0 (1) 30.5 (1) 31.0 (1) 30.5 (1) 32.5 (1) 33.5 (1) 36.0 (1) Bypass Ultra high/High/Low dBA 34.5 (1)/ 38.0 (1)/ 38.0 (1)/ 40.0 (1)/ 42.5 (1)/ 42.0 (1)/ 45.0 (1)/ 27.0 /26.5 28.0 /27.0 32.0 (1)/ 35.0 (1)/ 34.5 (1)/ 36.5 (1)/ 40.0 (1)/ 39.0 (1)/ 41.0 (1)/ mode /20.5 /21.0 28.0 (1) 29.5 (1) 30.5 (1) 30.5 (1) 32.5 (1) 32.5 (1) 35.0 (1) Operation range Around unit °CDB - 0°C~40°CDB, 80% RH or less Connection duct diameter mm 100 150 200 250 2x250 Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220 Current Maximum fuse amps (MFA) A 15.0 16.0 Specific energy Cold climate kWh/(m².a) -56.0 (5) -60.5 (5) - consumption (SEC) Average climate kWh/(m².a) -22.1 (5) -27.0 (5) - Warm climate kWh/(m².a) -0.100 (5) -5.30 (5) - SEC class D / See note 5 B / See note 5 - Maximum flow rate Flow rate m³/h 130 207 - at 100 Pa ESP Electric power input W 129 160 - Sound power level (Lwa) dB 40 43 51 54 58 61 62 65 Annual electricity consumption kWh/a 18.9 (5) 13.6 (5) - Annual heating Cold climate kWh/a 41.0 (5) 40.6 (5) - saved Average climate kWh/a 80.2 (5) 79.4 (5) - Warm climate kWh/a 18.5 (5) 18.4 (5) -

(1)Measured according to JIS B 8628 | (2)Measured at reference flow rate according to EN13141-7 | Measured according to EN308 : 1997 | In accordance with commission regulation (EU) No 1254/2014 | In accordance with commission regulation (EU) No 1253/2014 | At reference flow rate in accordance with commission regulation (EU) No 1254/2014 | Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency.

26 VKM-GB/VKM-GBM Energy reclaim ventilation, humidification and air processing

Pre heating or cooling of fresh air for lower load on the air conditioning system

›› Energy saving ventilation using indoor heating, cooling and moisture recovery ›› Creates a high quality indoor environment by pre conditioning incoming fresh air ›› Humidification of the incoming air results in comfortable indoor humidity level, even during heating ›› Free cooling possible when outdoor temperature is below indoor temperature (eg. during nighttime) VKM80-100GB(M) ›› Low energy consumption thanks to DC fan motor ›› Prevent energy losses from over-ventilation while improving indoor air quality with optional CO2 sensor ›› Shorter installation time thanks to easy adjustment of nominal air flow rate, so less need for dampers compared with traditional installation ›› Specially developed heat exchange element with High Efficiency Paper (HEP) ›› Can operate in over- and under pressure VAM/VKM

Ventilation VKM-GB/VKM-GBM 50GB 80GB 100GB 50GBM 80GBM 100GBM Power input - 50Hz Heat exchange Nom. Ultra high/ kW 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ mode High/Low 0.170 0.192 0.230 0.170 0.192 0.230 Bypass mode Nom. Ultra high/ kW 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ 0.270/0.230/ 0.330/0.280/ 0.410/0.365/ High/Low 0.140 0.192 0.230 0.170 0.192 0.230 Fresh kW 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0 conditioning load Heating kW 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0 Temperature Ultra high/High/Low % exchange efficiency 76/76/77.5 78/78/79 74/74/76.5 76/76/77.5 78/78/79 74/74/76.5 - 50Hz Enthalpy exchange Cooling Ultra high/High/Low % 64/64/67 66/66/68 62/62/66 64/64/67 66/66/68 62/62/66 efficiency - 50Hz Heating Ultra high/High/Low % 67/67/69 71/71/73 65/65/69 67/67/69 71/71/73 65/65/69 Operation mode Heat exchange mode / Bypass mode / Fresh-up mode Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange Heat exchange element Specially processed non-flammable paper Humidifier System - Natural evaporating type Dimensions Unit HeightxWidthxDepth mm 387x1,764x832 387x1,764x1,214 387x1,764x832 387x1,764x1,214 Weight Unit kg 94 110 112 100 119 123 Casing Material Galvanised steel plate Fan-Air flow rate Heat exchange mode Ultra high/High/Low m³/h 500/500/440 750/750/640 950/950/820 500/500/440 750/750/640 950/950/820 - 50Hz Bypass mode Ultra high/High/Low m³/h 500/500/440 750/750/640 950/950/820 500/500/440 750/750/640 950/950/820 Fan-External static Ultra high/High/Low Pa 210/170/140 210/160/110 150/100/70 200/150/120 205/155/105 110/70/60 pressure - 50Hz Air filter Type Multidirectional fibrous fleeces Sound pressure Heat exchange mode Ultra high/High/Low dBA 39/37/35 41.5/39/37 41/39/36.5 38/36/34 40/37.5/35.5 40/38/35.5 level - 50Hz Bypass mode Ultra high/High/Low dBA 40/38/35.5 41.5/39/37 41/39/36.5 39/36/34.5 41/38/36 41/39/35.5 Operation range Around unit °CDB 0°C~40°CDB, 80% RH or less Supply air °CDB -15°C~40°CDB, 80% RH or less Return air °CDB 0°C~40°CDB, 80% RH or less On coil temperature Cooling/Max./Heating/Min. °CDB -15/43 -15/43 Control Electronic expansion valve Type R-410A GWP 2,087.5 Connection duct diameter mm 200 250 200 250 Piping connections Liquid OD mm 6.35 Gas OD mm 12.7 Water supply mm - 6.4 Drain PT3/4 external thread Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 Current Maximum fuse amps (MFA) A 15

27 For small to large commercial spaces Daikin offers a range of inverter condensing units for use in conjunction with air handling units. In situations where Daikin commercial range ventilation units cannot satisfy the ventilation requirement due to building constraints (large atriums, banquet halls etc), air handling units represent the ideal solution. Air handling units provide large fresh air volumes (>500 m3/h) and high ESPs enabling the use of extensive ductwork runs.

An or air handling unit provides a tailor-made solution for optimising air conditions throughout multiple spaces. An air handling can be customised to your building - with no installation restrictions or design limitations - as air handling units are based on a completely unique modular design, so they can be sized (in increments of 1 cm) to your exact requirements.

28 Daikin air handling units

Ventilation

Energy Humidification recovery

Air Filtration processing

AHU

Air handling unit applications UNITS HANDLING AIR

Why choose Daikin air handling units with a DX connection? 30

Why use VRV and ERQ condensing units for connection to air handling units? 32

In order to maximise installation flexibility, 4 types of control systems are offered 33

VRV - for larger capacities (from 8 to 54HP) 34

ERQ - for smaller capacities (from 100 to 250 class) 35

Integration of VRV and ERQ in third party air handling units 36

Pair and multi application selection 37

29 Daikin air handling units solutions You will find your match

Why choose Daikin air handling units with a DX connection?

Simplifying business Complete range of possibilities

The unique total solution approach by Daikin helps Thanks to the most complete offer in the market, businesses to propose better cross-pillar solutions, to Daikin has the solution for all types of commercial increase their success ratio by providing unmatchable applications requiring fresh air. Daikin provides product combinations to the end-user and to ventilation solutions based on AHU from 2,500 m3/h simplify the life of installers by supplying high-quality up to 140,000 m3/h either with natural heat recovery products coming from the same manufacturer. or more advanced ventilation solutions where a Contrary to other manufacturers, Daikin does not VRV outdoor unit can be connected to the Daikin use OEM products in its AHU with DX offer. Many AHU for ultimate climate control. The harmonized competitors are either offering OEM DX outdoor units control between the VRV outdoor unit and the AHU or OEM AHU which create additional problems when offer outstanding 24h/7 control of the system when warranties or faults arise. Having a single interface connected to an iTM. for your business makes Daikin the right choice.

One stop shop

Daikin is the only global manufacturer in the market capable of offering a true Plug & Play solution where Daikin AHUs manufactured by Daikin Applied Europe and certified by Eurovent, offer off-the-shelf Advantages compatibility with Daikin’s unique VRV outdoor unit range for the best performance in the market. ›› Unique manufacturer offering a complete This unique integration of cross-pillar products under range the same umbrella, gives the costumer both peace-of- ›› Plug & Play solution mind and added value when promoting a total solution ›› Direct iTM compatibility approach.

30 Daikin's fresh air solution

High efficient EC fan Factory fitted and tested DX heat exchanger AIR HANDLING UNITS HANDLING AIR

Efficient filtration Heat wheel for heat recovery

31 Daikin Fresh air package - overview

Why use VRV and ERQ condensing units for connection to air handling units?

High Efficiency

Daikin heat pumps are renowned for their high while the outdoor air is too cold to be brought energy efficiency. Integrating the AHU with a heat inside in an unconditioned state. In this case heat recovery system is even more effective since from the offices is merely transferred to heat up an office system can frequently be in cooling mode the cold incoming fresh air.

Outside air = 10°C

Fresh air supplied at 21°C. The temperature difference with the outdoor air is heated up for free by heat recovery via A/C system

Indoor temperature 22°C, needs cooling because of solar radiation. The excessive heat can be transferred to the AHU.

Fast response to changing loads resulting in high comfort levels Easy Design and Installation

Daikin ERQ and VRV units respond rapidly The system is easy to design and install since to fluctuations in supply air temperature, resulting no additional water systems such as , in a steady indoor temperature and resultant high tanks and gas connections etc. are required. comfort levels for the end user. The ultimate is This also reduces both the total system investment the VRV range which improves comfort even more and running cost. by offering continuous heating, also during defrost.

Daikin Fresh air package

›› Plug & Play connection between VRV/ERQ and the entire D-AHU modular range. ›› Factory fitted and welded control and expansion valve kits.

VRV IV or ERQ condensing unit

Factory fitted and welded fresh air package

Electronic expansion valve Control box (EKEXV) (EKEQ)

32 Daikin Fresh air package - Controls

In order to maximise installation flexibility, 4 types of control systems are offered

W control: Off the shelf control of air temperature (discharge Z control: Control of air temperature (suction temperature, room temperature, suction temperature, room temperature) via any temperature) via Daikin control (no DDC controller needed) DDC controller, easy to setup Y control: Control of refrigerant (Te/Tc) temperature via Daikin X control: Precise control of air temperature (discharge temperature, control (no DDC controller needed) suction temperature, room temperature) requiring a preprogrammed DDC controller (for special applications)

1. W control (TS/TR/TROOM control): 2. X control (TS/TR/TROOM control):

Air temperature control via DDC controller Precise air temperature control via DDC controller Room temperature is controlled as a function of the air handling Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The DDC unit suction or discharge air (customer selection). The DDC controller is translating the temperature difference between set controller is translating the temperature difference between set point and air suction temperature (or air discharge temperature point and air suction temperature (or air discharge temperature or room temperature) into a proportional 0-10V signal which is or room temperature) into a reference voltage (0-10V) which is transferred to the Daikin control box (EKEQFCBA). This voltage transferred to the Daikin control box (EKEQFCBA). This reference modulates the capacity requirements of the outdoor unit. voltage will be used as the main input value for the frequency control.

OROR OROR AHUAHU AHUAHU

TEEXTXT TR TEEXTXT TR TR TR 0-10V DaikinCo ncontroltrol box box: 0-10V DaikinCo ncontroltrol box box: DDCDDC + DDCDDC + EKEQFCBAEKEQFCBA T T EKEQFCBAEKEQFCBA T E C T TET TOOAA TS TOOAA C TS - S - S

T T TROOMROOM TROOMROOM

4. Z control (TS/TROOM control): 3. Y control (TE/TC control): Control your AHU just like a VRV indoor unit with 100% fresh air By fixed evaporating /condensing temperature Allows the possibility to control the AHU just like a VRV indoor A fixed target evaporating or condensing temperature can be set unit. Meaning temperature control will be focused on return air UNITS HANDLING AIR by the customer. In this case, room temperature is only indirectly temperature from the room into the AHU. Requires BRC1* for controlled. A Daikin wired remote control (BRC1* - optional) have to operation. The only control that allows the combination of other be connected for initial set-up but not required for operation. indoor units to the AHU at the same time.

AAHUHU TTEXT TT BRC1D* EXT RR BRC1D* CControlontrol bboxox T T BRC1E* + EXTEXT R BRC1E* EEKEQFCBAKEQFCBA T BRC1D* ControlControl boxbox BRC1H* TE C BRC1D* TTOOAA T BRC1E* EEKEQMCBAKEQMCBA (VRV(VRV IV)IV) S BRC1E* + - BRC1H* EEKEQDCBKEQDCB (ERQ)(ERQ) T TTOA E OA TC TS -

TTROOM ROOM OROR T TRROOMOOM

T = Outdoor air temperature T = Room air temperature TS = Supply air temperature TR = Return air temperature OA ROOM T = Condensing temperature TEXT = Extraction air temperature TE = Evaporating temperature C

Option kit Features Possibility W Off-the-shelf DDC controller that requires no pre-configuration Possibility X EKEQFCBA Pre-configured DDC controller required Possibility Y Using fixed evaporating temperature, no set point can be set using remote control EKEQDCB Using Daikin infrared remote control BRC1* Possibility Z EKFQMCBA* Temperature control using air suction temperature or room temperature (via remote sensor)

* EKEQMCB (for ’multi’ application)

33 Daikin Fresh air package - VRV connections

- for larger capacities (from 8 to 54HP)

An advanced solution for both pair and multi application

›› Inverter controlled units ›› Heat recovery, ›› R-410A ›› Control of room temperature via Daikin control ›› Large range of expansion valve kits available ›› BRC1H519W/S/K is used to set the set point temperature (connected to the EKEQMCBA). ›› Connectable to all VRV heat recovery and heat pump systems

W, X, Y control for VRV IV heat pump Z control for all VRV outdoor units

Refrigerant piping F1-F2 P1-P2

34 Daikin Fresh air package - ERQ connections

ERQ - for smaller capacities (from 100 to 250 class)

A basic fresh air solution for pair application

›› Inverter controlled units ›› Heat pump ›› R-410A ›› Wide range of expansion valve kits available ›› Perfect for the Daikin Modular air handling unit ERQ-AW1 The “Daikin Fresh Air Package” provides a complete Plug & Play Solution including AHU, ERQ or VRV Condensing Unit and all unit control (EKEQ, EKEX, DDC controller) factory mounted and configured. The easiest solution with only one point of contact.

Ventilation ERQ 100AV1 125AV1 140AV1 Capacity range HP 4 5 6 Cooling capacity Nom. kW 11.2 14.0 15.5 Heating capacity Nom. kW 12.5 16.0 18.0 Power input Cooling Nom. kW 2.81 3.51 4.53 Heating Nom. kW 2.74 3.86 4.57 EER 3.99 3.42 COP 4.56 4.15 3.94 Dimensions Unit HeightxWidthxDepth mm 1,345x900x320 Weight Unit kg 120 Casing Material Painted galvanized steel plate Fan-Air flow rate Cooling Nom. m³/min 106 Heating Nom. m³/min 102 105 Sound power level Cooling Nom. dBA 66 67 69 Sound pressure Cooling Nom. dBA 50 51 53 level Heating Nom. dBA 52 53 55 Operation range Cooling Min./Max. °CDB -5/46 Heating Min./Max. °CWB -20/15.5 On coil temperature Heating/Min./Cooling/Max. °CDB 10/35 Refrigerant Type R-410A Charge kg 4.0 TCO₂eq 8.4 GWP 2,087.5 Control Expansion valve (electronic type) UNITS HANDLING AIR Piping connections Liquid OD mm 9.52 Gas OD mm 15.9 19.1 Drain OD mm 26x3 Power supply Phase/Frequency/Voltage Hz/V 1N~/50/220-240 Current Maximum fuse amps (MFA) A 32.0 Ventilation ERQ 125AW1 200AW1 250AW1 Capacity range HP 5 8 10 Cooling capacity Nom. kW 14.0 22.4 28.0 Heating capacity Nom. kW 16.0 25.0 31.5 Power input Cooling Nom. kW 3.52 5.22 7.42 Heating Nom. kW 4.00 5.56 7.70 EER 3.98 4.29 3.77 COP 4.00 4.50 4.09 Dimensions Unit HeightxWidthxDepth mm 1,680x635x765 1,680x930x765 Weight Unit kg 159 187 240 Casing Material Painted galvanized steel plate Fan-Air flow rate Cooling Nom. m³/min 95 171 185 Heating Nom. m³/min 95 171 185 Sound power level Nom. dBA 72 78 Sound pressure level Nom. dBA 54 57 58 Operation range Cooling Min./Max. °CDB -5/43 Heating Min./Max. °CWB -20/15 On coil temperature Heating/Min./Cooling/Max. °CDB 10/35 Refrigerant Type R-410A Charge kg 6.2 7.7 8.4 TCO₂eq 12.9 16.1 17.5 GWP 2,087.5 Control Electronic expansion valve Piping connections Liquid OD mm 9.52 Gas OD mm 15.9 19.1 22.2 Power supply Phase/Frequency/Voltage Hz/V 3N~/50/400 Current Maximum fuse amps (MFA) A 16 25

35 Integration with third party air handling units

Integration of ERQ and VRV in third party air handling units a wide range of expansion valve kits and control boxes

Combination table

Control box Expansion valve kit Mixed connection with EKEQDCB EKEQFCBA EKEQMCBA EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500 VRV indoor units Z control W,X,Y control Z control ------ERQ100 P P - - P P P P - - - - - 1-phase ERQ125 P P - - P P P P P - - - - ERQ140 P P - - - P P P P - - - - Not possible ERQ125 P P - - P P P P P - - - - 3-phase ERQ200 P P - - - - P P P P P - - ERQ250 P P - - - - - P P P P - - VRV III - - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory VRV IV H/P / VRV IV W-series - P (1 -> 3) n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 Possible (not VRV IV S-series mandatory) VRV IV H/R VRV IV i-series - n1 - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory • P (pair application): combination depends on the capacity of the air handling unit • n1 (multi application) - Combination of AHUs and VRV DX indoors (mandatory). To determine the exact quantity please refer to the engineering data book. • n2 (multi application) - Combination of AHUs and VRV DX indoors (not mandatory). To determine the exact quantity please refer to the engineering data book. • Control box EKEQFA can be connected to some types of VRV IV outdoor units (with a maximum of 3 boxes per unit). Do not combine EKEQFA control boxes with VRV DX indoor units, RA indoor units or hydroboxes

Capacity table

Cooling Heating Allowed heat exchanger Allowed heat exchanger Allowed heat exchanger Allowed heat exchanger EKEXV Class capacity (kW) volume (dm3) EKEXV Class capacity (kW) volume (dm3) Minimum Standard Maximum Minimum Maximum Minimum Standard Maximum Minimum Maximum 50 5.0 5.6 6.2 1.33 1.65 50 5.6 6.3 7.0 1.33 1.65 63 6.3 7.1 7.8 1.66 2.08 63 7.1 8.0 8.8 1.66 2.08 80 7.9 9.0 9.9 2.09 2.64 80 8.9 10.0 11.1 2.09 2.64 100 10.0 11.2 12.3 2.65 3.30 100 11.2 12.5 13.8 2.65 3.30 125 12.4 14.0 15.4 3.31 4.12 125 13.9 16.0 17.3 3.31 4.12 140 15.5 16.0 17.6 4.13 4.62 140 17.4 18.0 19.8 4.13 4.62 200 17.7 22.4 24.6 4.63 6.60 200 19.9 25.0 27.7 4.63 6.60 250 24.7 28.0 30.8 6.61 8.25 250 27.8 31.5 34.7 6.61 8.25 400 35.4 45.0 49.5 9.26 13.2 400 39.8 50.0 55.0 9.26 13.2 500 49.6 56.0 61.6 13.2 16.5 500 55.1 63.0 69.3 13.2 16.5 Saturated evaporating temperature: 6°C Saturated condensing temperature: 46°C Air temperature: 27°C DB / 19°C WB Air temperature: 20°C DB

EKEXV - Expansion valve kit for air handling applications

Ventilation EKEXV 50 63 80 100 125 140 200 250 400 500 Dimensions Unit mm 401x215x78 Weight Unit kg 2.9 Sound pressure level Nom. dBA 45 Operation range On coil Heating Min. °CDB 10 (1) temperature Cooling Max. °CDB 35 (2) Refrigerant Type / GWP R-410A / 2.087,5 Piping connections Liquid OD mm 6.35 9.52 12.7 15.9

(1) The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information. (2) 45% Relative humidity.

EKEQ - Control box for air handling applications

Ventilation EKEQ FCBA DCB MCBA Application See note Pair Multi Outdoor unit ERQ / VRV ERQ VRV Dimensions Unit mm 132x400x200 Weight Unit kg 3.9 3.6 Power supply Phase/Frequency/Voltage Hz/V 1~/50/230

The combination of EKEQFCBA and ERQ is in pair application. The EKEQFCBA can be connected to some type of VRV IV outdoor units with a maximum of 3 control boxes. The combination with DX indoor units, hydroboxes, RA outdoor units, ... is not allowed. Refer to the combination table drawing of the outdoor unit for details.

36 Selection

Pair application selection

›› the outdoor unit is connected to ONE COIL (with single circuit or maximum 3 interlaced circuits) using up to 3 control boxes ›› indoor unit combination is not allowed ›› only works with X, W, Y control

Step 1: Required AHU capacity Step 3: Control box selection

An AHU with double flow, heat recovery and 100% fresh air is to In this particular case, the control will work with precise air be installed in Europe where the outdoor sizing temperature is 35 temperature control. Only W or X control allow this. Since the ºCDB and the target supply air temperature for fresh air is 25 ºCDB. consultant wants to use an “off-the-shelf” DDC module, the Load calculations point to a required capacity of 45kW. EKEQFCBA box with W control allows easy set-up due to pre-set By checking on the EKEXV capacity table, for cooling operation, factory values. 40kW falls within the 400 class valve. Since 40kW is not the nominal capacity, a class adjustment has to be done. 40/45=0,89 and 0,89x400=356. So the capacity class of the expansion valve kit is 356.

Step 2: Outdoor unit selection

For this AHU, a VRV IV heat pump model with continuous heating is going to be used (RYYQ-T series). For a capacity of 40kW at 35 ºCDB, an outdoor of 14HP (RYYQ14T) is selected. The capacity class of the 14 HP outdoor unit is 350.

Total connection ratio of the system is 356/350=102% hence it falls within the range 90-110%.

Multi application selection AIR HANDLING UNITS HANDLING AIR

›› the outdoor unit can be connected to MULTIPLE COILS (and their control boxes) ›› indoor units are also connectable but not mandatory ›› only works with Z control

Step 1: Required AHU capacity Step 2: Outdoor unit selection

An AHU with double flow, heat recovery and 100% fresh air is to be installed in Europe where the outdoor sizing temperature is For this system where a AHU is connected with indoor units, it is 35 ºCDB and the target supply air temperature for fresh air is 25 mandatory to use a heat recovery unit. By consulting the engi- ºCDB. On top of this, for this building, 5 round-flow cassette units neering databook for REYQ-T, the total required capacity of 42,5 FXFQ50A will also be connected to this OU. kW requires a 16HP model REYQ16T. Which will deliver 45kW at the Load calculations point to a required capacity of 20kW for the AHU design temperature of 35 ºCDB. This unit has a capacity class of 400. and 22,5 kW for the indoor untis. Total connection ratio of the system is 428/400=107% hence it falls By checking on the EKEXV capacity table, for cooling operation, within the range 50-110%. 20kW falls within the 200 class valve. Since 22,4 kW is the nominal capacity, a class adjustment has to be done. 20/22,4=0,89 and Step 3: Control box selection 0,89x200=178. So the capacity class of the expansion valve kit is 178. Total capacity class of the indoor unit system is 178+250=428 In this particular case, the only available control is Z control and the combination of AHU and VRV DX indoor units requires EKEQMCBA control box.

37 Air handling application

Pair application examples Pair application layout #1: Example for W or X control with EKEQFCBA box

F1/F2

EKEQFCBA EKEKXV* Digital signal to steer EEV Treturn

Only for commissioning OR

Tsupply

0-10 V signal Temperature sensor reading From DDC to EKEQFCBA input to DDC

Outdoor unit compatibility More than 3 control boxes RYYQ8T > RYYQ54T connected to same outdoor

RXYQ8T > RXYQ54T coil DX RWEYQ8T9 > RWEYQ30T9 ERQ100 > ERQ250 1

(1) Only available in 1 to 1 combination Two control boxes connected to Outdoor 1 to circuits 1 Connection restrictions and 2 of coil A. Control box 3

Connection Ratio VRV: between 90-110% coil DX connected to outdoor 2 and circuit 3 of coil A. Connection Ratio ERQ: between 50-110%

CR= Σ IU CC = Σ (CF x EKEXV CC)1-3 Σ OU CC Σ OU CC

CF is the correction factor CC is the capacity class Two control boxes on coil A (2 circuits) and another control DX coil DX box on coil B (1 circuit). Both connected to same outdoor DX coil DX

38 Air handling application

Pair application layout #2: Example for Y control with EKEQFCBA box

F1/F2

EKEQFCBA EKEKXV* Digital signal to steer EEV Treturn

Only for commissioning

Tsupply

Input signal from sensors AIR HANDLING UNITS HANDLING AIR

Outdoor unit compatibility More than 3 control boxes RYYQ8T > RYYQ54T connected to same outdoor

RXYQ8T > RXYQ54T coil DX RWEYQ8T9 > RWEYQ30T9 ERQ100 > ERQ250 1

(1) Only available in 1 to 1 combination Two control boxes connected to Outdoor 1 to circuits 1 Connection restrictions and 2 of coil A. Control box 3

Connection Ratio between 90-110% coil DX connected to outdoor 2 and OK circuit 3 of coil A. Connection Ratio ERQ: between 50-110%

CR= Σ IU CC = Σ (CF x EKEXV CC)1-3 Σ OU CC Σ OU CC

CF is the correction factor CC is the capacity class Two control boxes on coil A (2 circuits) and another control DX coil DX OK box on coil B (1 circuit). Both connected to same outdoor DX coil DX

39 Air handling application

Multi application examples Multi application layout #1: Example for Z control with EKEQMCBA box and no VRV indoor units

F1/F2 Mandatory

EKEQMCBA EKEKXV* Digital signal to steer EEV

OR

ROOM

KRCS01-1B

n control boxes Input signal from sensors OR

Outdoor unit compatibility More than 3 control boxes RYYQ8T > RYYQ54T connected to same outdoor OK RXYQ8T > RXYQ54T DX coil DX RWEYQ8T9 > RWEYQ30T9

EKEQMCBA control box Two control boxes connected ERQ100 > ERQ250 1 to Outdoor 1 to circuits 1 EKEQDCB control box and 2 of coil A. Control box 3 connected to outdoor 2 and (1) Only available in 1 to 1 combination coil DX OK circuit 3 of coil A. Connection restrictions Connection Ratio between 90-110% Connection Ratio ERQ: between 50-110% Two control boxes on coil A CR= Σ IU CC = Σ (CF x EKEXV CC)1-n (2 circuits) and another control

Σ OU CC Σ OU CC coil DX OK box on coil B (1 circuit). Both connected to same CF is the correction factor outdoor

CC is the capacity class coil DX

40 Air handling application

Multi application layout #2: Example for Z control with EKEQMCBA box and VRV indoor units

F1/F2 Mandatory

EKEQMCBA EKEKXV* Digital signal to steer EEV

OR

ROOM

KRCS01-1B

n control boxes AIR HANDLING UNITS HANDLING AIR

Input signal from sensors OR

Outdoor unit compatibility More than 3 control boxes Not mandatory to have VRV DX indoors: connected to same outdoor OK RYYQ8T > RYYQ54T DX coil DX RXYQ8T > RXYQ54T

RWEYQ8T9 > RWEYQ30T9 Two control boxes connected Mandatory to have VRV DX indoors: to Outdoor 1 to circuits 1 REYQ8T > REYQ54T and 2 of coil A. Control box 3 connected to outdoor 2 and DX coil DX Connection restrictions OK circuit 3 of coil A. Connection Ratio between 50-110%

CR= Σ IU CC = Σ (CF x EKEXV CC)1-n Σ OU CC Σ OU CC Two control boxes on coil A (2 circuits) and another control

RULES: Σ EKEXV CC: 0-60% Σ IU CC: 50-110% coil DX OK coil DX box on coil B (1 circuit). CF is the correction factor Both connected to same CC is the capacity class DX coil DX outdoor DX coil DX

41 Options & accessories

Options & accessories

FILTERS

VH ELECTRICAL HEATER FOR VAM

CONTROLS

42 User-friendly wired remote contoller with premium design

White Silver Black

BRC1H519W/S/K ›› Sleek and elegant design ›› Intuitive touch button control ›› 3 color versions ›› Advanced settings and monitoring can ACCESSORIES & OPTIONS be easily done via your smartphone Advanced user settings Field settings ›› Flat back for easy wall installation ›› Compact to fit standard size socket boxes

DIRECT INTEGRATION WITH DAIKIN VENTILATION PRODUCTS

43 Heat Recovery Ventilation - Modular L (Smart) Energy reclaim ventilation - VAM Energy reclaim ventilation VKM Air handling unit applications

ALB04,05LBS/ ALB06,07LBS/ VAM VAM VAM VAM VAM VAM VAM VAM VAM VKM VKM VKM EKEQ EKEQ EKEQ ALB02LBS/RBS ALB03LBS/RBS RBS RBS 150FC 250FC 350J 500J 650J 800J 1000J 1500J 2000J 50GB (M) 80GB (M) 100GB (M) FCBA (1) DCB (1) MCBA (1)

BRC301B61 VAM wired remote control • • • • • • • • • • • • • Madoka BRC1H519W (Glossy white) / BRC1H519S (Silver Metallic) / BRC1H519K (Black matte) • • • • • • • • • • • • • • • • • • • User-friendly wired remote controller with premium design BRC1E53A/B/C Wired remote control with full-text • • • • • • • • • • • • • • • • • • • interface and back-light BRC1D52 Individual control systems control Individual Standard wired remote control with weekly timer • • • • • • • • • • • • • • • • • • • DCC601A51 intelligent Tablet Controller • • • • • • • • • • • • • • • • • • • DCM601A51 intelligent Touch Controller • • • • • • • • • • • • • • • • • • • DCS302C51 Central remote control • • • • • • • • • • • • • • • • systems DCS301B51 Unified ON/OFF control • • • • • • • • • • • • • • • • Centralised control control Centralised DST301B51 Schedule timer • • • • • • • • • • • • • • • • DCM601A51 intelligent Touch Manager • • • • • • • • • • • • • • • • • • • EKMBDXA Modbus interface • • • • • • • • • • • • • • • • • • • DMS502A51 Building Building interface BACnet Interface • • • • • • • • • • • • • • • • DMS504B51 & Standard protocol protocol Standard & Management System System Management LonWorks Interface • • • • • • • • • • • • • • • •

Coarse 55% (G4) ALF02G4A ALF03G4A ALF05G4A ALF07G4A

ALF02M5A ALF03M5A ALF05M5A ALF07M5A ePM10 75% (M5)

EKAFVJ50F6 EKAFVJ50F6 EKAFVJ65F6 EKAFVJ100F6 EKAFVJ100F6 EKAFVJ100F6 x2 EKAFVJ100F6 x2 ePM10 70% (M6)

ALF02F7A ALF03F7A ALF05F7A ALF07F7A ePM1 50% (F7)

EKAFVJ50F7 EKAFVJ50F7 EKAFVJ65F7 EKAFVJ100F7 EKAFVJ100F7 EKAFVJ100F7 x2 EKAFVJ100F7 x2 ePM1 55% (F7) Filters

EKAFVJ50F8 EKAFVJ50F8 EKAFVJ65F8 EKAFVJ100F8 EKAFVJ100F8 EKAFVJ100F8 x2 EKAFVJ100F8 x2 ePM1 70% (F8)

ALF02F9A ALF03F9A ALF05F9A ALF07F9A ePM1 80% (F9)

High efficiency filter KAF242H80M KAF242H100M KAF242H100M

Replacement air filter KAF241H80M KAF241H100M KAF241H100M

Rail ALA02RLA ALA03RLA ALA05RLA ALA07RLA

Rectangular to round duct transition ALA02RCA ALA03RC ALA05RCA ALA07RCA

EKPLEN200 (6) EKPLEN200 (6) accessories Mechanical Mechanical Separate plenum

BRYMA200 BRYMA200 BRYMA200 BRYMA200 BRYMA65 BRYMA65 BRYMA65 BRYMA100 BRYMA100 BRYMA200 BRYMA200 BRYMA65 BRYMA100 BRYMA200 CO2 sensor (preliminary) (preliminary) (preliminary) (preliminary)

Electrical heater ALD02HEFB ALD03HEFB ALD05HEFB ALD07HEFB VH1B VH2B VH3B VH3B VH4B / VH4/AB VH4B / VH4/AB VH4B / VH4/AB VH5B(7) VH5B(7)

Silencer (900mm depth) ALS0290A ALS0390A ALS0590A ALS0790A Wiring adapter for external monitoring/control KRP2A51 KRP2A51 KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4) (controls 1 entire system) Adapter PCB for humidifier KRP50-2 KRP50-2 KRP1C4 (5) KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (5) KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (3/5) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

Adapter PCB for third party heater BRP4A50 BRP4A50 BRP4A50A (4) BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

External wired temperature sensor KRCS01-1

Electrical accessories Adapter PCB Mounting plate EKMP65VAM EKMPVAM Notes (1) Do not connect the system to DIII-net devices LONWorks interface, BACnet interface, …; (intelligent Touch Manager, EKMBDXA are allowed) (2) Installation box KRP1BA101 needed (3) Adapter PCB mounting plate needed, applicable model can be found in the table above (4) 3rd party heater and 3rd party humidifier cannot be combined (5) Installation box KRP50-2A90 needed (6) Contains 1 plenum and can be used for half side of the unit (up to 4 plenums can be used on 1 unit) (7) Available only with optional plenum

44 Heat Recovery Ventilation - Modular L (Smart) Energy reclaim ventilation - VAM Energy reclaim ventilation VKM Air handling unit applications

ALB04,05LBS/ ALB06,07LBS/ VAM VAM VAM VAM VAM VAM VAM VAM VAM VKM VKM VKM EKEQ EKEQ EKEQ ALB02LBS/RBS ALB03LBS/RBS RBS RBS 150FC 250FC 350J 500J 650J 800J 1000J 1500J 2000J 50GB (M) 80GB (M) 100GB (M) FCBA (1) DCB (1) MCBA (1)

BRC301B61 VAM wired remote control • • • • • • • • • • • • • Madoka BRC1H519W (Glossy white) / BRC1H519S (Silver Metallic) / BRC1H519K (Black matte) • • • • • • • • • • • • • • • • • • • User-friendly wired remote controller with premium design BRC1E53A/B/C Wired remote control with full-text • • • • • • • • • • • • • • • • • • • interface and back-light BRC1D52 Individual control systems control Individual Standard wired remote control with weekly timer • • • • • • • • • • • • • • • • • • • DCC601A51 intelligent Tablet Controller • • • • • • • • • • • • • • • • • • • DCM601A51 intelligent Touch Controller • • • • • • • • • • • • • • • • • • • DCS302C51 Central remote control • • • • • • • • • • • • • • • • systems DCS301B51 Unified ON/OFF control • • • • • • • • • • • • • • • • Centralised control control Centralised DST301B51 Schedule timer • • • • • • • • • • • • • • • • DCM601A51 intelligent Touch Manager • • • • • • • • • • • • • • • • • • • EKMBDXA Modbus interface • • • • • • • • • • • • • • • • • • • DMS502A51 Building Building interface BACnet Interface • • • • • • • • • • • • • • • • DMS504B51 & Standard protocol protocol Standard & Management System System Management LonWorks Interface • • • • • • • • • • • • • • • •

Coarse 55% (G4) ALF02G4A ALF03G4A ALF05G4A ALF07G4A

ALF02M5A ALF03M5A ALF05M5A ALF07M5A ePM10 75% (M5)

EKAFVJ50F6 EKAFVJ50F6 EKAFVJ65F6 EKAFVJ100F6 EKAFVJ100F6 EKAFVJ100F6 x2 EKAFVJ100F6 x2 ePM10 70% (M6)

ALF02F7A ALF03F7A ALF05F7A ALF07F7A ePM1 50% (F7)

EKAFVJ50F7 EKAFVJ50F7 EKAFVJ65F7 EKAFVJ100F7 EKAFVJ100F7 EKAFVJ100F7 x2 EKAFVJ100F7 x2 ePM1 55% (F7) Filters

EKAFVJ50F8 EKAFVJ50F8 EKAFVJ65F8 EKAFVJ100F8 EKAFVJ100F8 EKAFVJ100F8 x2 EKAFVJ100F8 x2 ePM1 70% (F8)

ALF02F9A ALF03F9A ALF05F9A ALF07F9A ePM1 80% (F9)

High efficiency filter KAF242H80M KAF242H100M KAF242H100M

Replacement air filter KAF241H80M KAF241H100M KAF241H100M

Rail ALA02RLA ALA03RLA ALA05RLA ALA07RLA

Rectangular to round duct transition ALA02RCA ALA03RC ALA05RCA ALA07RCA

EKPLEN200 (6) EKPLEN200 (6) accessories Mechanical Mechanical Separate plenum

BRYMA200 BRYMA200 BRYMA200 BRYMA200 BRYMA65 BRYMA65 BRYMA65 BRYMA100 BRYMA100 BRYMA200 BRYMA200 BRYMA65 BRYMA100 BRYMA200 CO2 sensor (preliminary) (preliminary) (preliminary) (preliminary)

Electrical heater ALD02HEFB ALD03HEFB ALD05HEFB ALD07HEFB VH1B VH2B VH3B VH3B VH4B / VH4/AB VH4B / VH4/AB VH4B / VH4/AB VH5B(7) VH5B(7) ACCESSORIES & OPTIONS

Silencer (900mm depth) ALS0290A ALS0390A ALS0590A ALS0790A Wiring adapter for external monitoring/control KRP2A51 KRP2A51 KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) KRP2A51 (2) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4) (controls 1 entire system) Adapter PCB for humidifier KRP50-2 KRP50-2 KRP1C4 (5) KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (5) KRP1C4 (5) KRP1C4 (3/5) KRP1C4 (3/5) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

Adapter PCB for third party heater BRP4A50 BRP4A50 BRP4A50A (4) BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (3/4) BRP4A50A (3/4) BRP4A50A (4) BRP4A50A (4) BRP4A50A (4)

External wired temperature sensor KRCS01-1

Electrical accessories Adapter PCB Mounting plate EKMP65VAM EKMPVAM Notes (1) Do not connect the system to DIII-net devices LONWorks interface, BACnet interface, …; (intelligent Touch Manager, EKMBDXA are allowed) (2) Installation box KRP1BA101 needed (3) Adapter PCB mounting plate needed, applicable model can be found in the table above (4) 3rd party heater and 3rd party humidifier cannot be combined (5) Installation box KRP50-2A90 needed (6) Contains 1 plenum and can be used for half side of the unit (up to 4 plenums can be used on 1 unit) (7) Available only with optional plenum

45 ALD-HEFB Electrical heater for Modular L smart

›› Total solution for fresh air with Daikin supply of both Modular L Smart and electrical heaters ›› Increase comfort in low outdoor temperature thanks to the heated outdoor air ›› Integrated electrical heater concept (no additional accessories required) ›› Standard dual flow and temperature sensor ›› Heater only consumes what is required to pre-heat to the desired minimum fresh air temperature; thus saving energy

Electrical heater for Modular L Smart (ALD) 02HEFB 03HEFB 05HEFB 07HEFB Capacity kW 1,5 3 7,5 15 Connectable Modular L Smart size 02 03 04, 05 06, 07 Supply voltage 230V,1ph 400V,3ph Output current (maximum) (A) 6,6 13,1 10,9 21,7

15k ohms at -20 °C 16k ohms at -20 °C 17k ohms at -20 °C 18k ohms at -20 °C Temperature sensor 10k ohms at +10 °C 10k ohms at +10 °C 10k ohms at +10 °C 10k ohms at +10 °C

Temperature control range - 20 °C to 10 °C

Control fuse Mini Circuit Breaker 6 A

"Yellow = Airflow fault LED indicators Red = Heat ON”

Mounting holes Depends on duct size Maximum ambient adjacent to terminal box 30°C (during operation) Auto high temp. cutout 75°C Pre-set Man. reset high temp.cutout 120°C Pre-set Width (mm) 470 620 720 920 Depth (mm) 370 370 370 370 Height (mm) 193 243 343 443

46 VH Electrical heater for VAM

›› Total solution for fresh air with Daikin supply of both VAM and electrical heaters ›› Increased comfort in low outdoor temperature thanks to the heated outdoor air ›› Integrated electrical heater concept (no additional accessories required) ›› Standard dual flow and temperature sensor ›› Flexible setting with adjustable setpoint ›› Increased safety with 2 cut-outs: manual & automatic ›› BMS integration thanks to: - Volt free relay for error indication - 0-10VDC input for setpoint control ʯʯ Heater only consumes what is required to pre-heat to the desired minimum fresh air temperature; thus saving energy

VH 1B 2B 3B 4B 4/AB 5B(1) Capacity kW 1 1.5 2.5 2.5 Duct diameter mm 100 150 200 250 300 Connectable VAM VAM150FC VAM250FC VAM350,500J VAM650J, VAM800J, VAM1000J VAM1500J, VAM2000J OPTIONS & ACCESSORIES & OPTIONS ELECTRICAL HEATER FOR VAM VH (VH) Supply voltage 220/250V ac 50/60 Hz. +/-10% Output current (maximum) 19A at 40°C (ambient) Temperature sensor 5k ohms at 25°C (table 502 1T) Temperature control range 0 to 40°C / (0-10V 0-100%) Control fuse 20 x 5mm 250mA LED indicators Power ON - Yellow Heater ON - Red (solid or flashing, indicating pulsed control) Airflow fault - Red Mounting holes 98mm x 181mm centres 5 mm ø holes Maximum ambient adjacent to terminal box 35°C (during operation) Auto high temp. cutout 100°C Pre-set Man. reset high temp. cutout 125°C Pre-set Run relay 1A 120V AC or 1A 24V DC BMS setpoint input 0-10VDC (1) Available only with the optional plenum

47 We’re here to help you! Online and offline

http://literature.daikinpromoshop.eu

Bene ts

We care icons

Seasonal e ciency, smart use of energy Econo mode Seasonal e ciency gives a more realistic indication on how This function decreases the power consumption so that other e cient air conditioners operate over an entire heating or cooling applicances that need large power consumption can be used. season. This function is also energy saving.

Auto-cleaning  lter Movement sensor The lter automatically cleans itself. Simplicity of upkeep means The sensor detects whether someone is in the room. When optimum energy e ciency and maximum comfort without the the room is empty, the unit switches to economy mode after need for expensive or time-consuming maintenance. 20 minutes and restarts when a person enters the room. Inverter technology Inverter continuously adjust compressor speed to Home leave operation actual demand. Fewer power-consuming starts and stops result During absence, the indoor temperature can be maintained at A big step setting the in decreased energy consumption (up to 30%) and more stable a certain level. temperatures. 2 area intelligent eye Air  ow is sent to a zone other than where the person is located Fan only at that moment. Detection is done in 2 directions: left and right. If The air conditioner can be used as fan, blowing air without no people are detected, the unit will automatically switch over to cooling or heating. new heat pump standard the energy-e cient setting. General catalogue 3 area intelligent eye Free cooling Air  ow is sent to a zone other than where the person is located By exploiting the low external air temperatures to cool the water, at that moment. Detection is done in 3 directions : left, front and free cooling reduces the load on the compressors and decreases 3 right. If no people are detected, the unit will automatically switch considerably the annual operating costs during the cold season. over to the energy-e cient setting and eventually switch o . Floor & presence sensor Energy saving during operation standby The presence sensor directs the air away from any person Current consumption is reduced by about 80 % when operating detected in the room, when the air  ow control is on. The  oor on standby. sensor detects the average  oor temperature and ensures an even

temperature distribution between ceiling and  oor. GENERAL CATALOGUE2018

Solar panel  Night set mode Saves energy, by preventing overcooling or overheating during Take advantage of solar power. Easily connect your hot water night time. storage to solar collectors on your roof.

Comfort Comfort mode Draught prevention The unit automatically changes the angle of the air discharge louvre When starting to warm up or when the is o , the air depending on the mode. In cooling operation the air will be directed discharge direction is set horizontally and the fan to low speed, to rather upwards to avoid cold draught, while in heating operation the prevent draught. After warming up, air discharge and fan speed air will be directed rather downwards to avoid cold feet. are set as desired. Powerful mode Auto cooling-heating changeover If the temperature in the room is too high/low, it can be cooled Automatically selects cooling or heating mode to achieve down/heated quickly by selecting the ‘powerful mode’. After the the set temperature (heat pump types only). powerful mode is turned o , the unit returns to the preset mode.

Impossible to hear Indoor unit silent operation Practically inaudible: the unit runs so quietly, you will almost To ensure a quiet environment for studying or sleeping the user forget it is there. can lower the operation sound of the indoor unit by 3 dB(A) via remote control. Night quiet mode (cooling only) Whisper quiet Lowers the operation sound of the outdoor unit automatically Daikin units are whisper quiet. (with sound levels as low as 19dBA) at night. Installer has to make special setting on outdoor unit or wired remote controller, depending on model. Outdoor unit silent operation The new generation Daikin Altherma 3 To ensure a quiet environment for the neighbourhood the user Radiant heat can lower the operation sound of the outdoor unit by 3 dB(A) via The front panel of the indoor unit radiates additional heat to add E M H I to your comfort on cold days S remote control. T

rd S

High performance - The 3 Generation of Daikin Altherma is I

N

O

Fresh hot water I

Comfortable sleeping mode N

The structure of thermal store ensures optimal water hygiene and taking you beyond the imaginable with its performance: A+++ O Increased comfort function that follows a speci c temperature eliminates the risk of bacteria and legionella. Rest assured that J  uctuation rhythm. your hot water is fresh and safe Seasonal e ciency and operation range down to -25°C.

Easy to install - The  oor standing unit only has a 60 cm Air ow E M E M H I H I S S 3-D Air  ow footprint and you can choose for white or silver-grey colour. T T

Ceiling soiling prevention This function combines Vertical and Horizontal auto-swing to S S

I I

A special function prevents air blowing out too long in horizontal N N

O O

I

circulate a stream of cool/warm air right to the corners of even I

position, to prevent ceiling stains. N N

O

large spaces. O J Easy to control - Fully digital, the Daikin Altherma 3 can be J

Vertical auto swing Horizontal auto swing controlled from everywhere with an app or a home control system. Possibility to select automatic vertical moving of the air discharge Possibility to select automatic horizontal moving of the air louvre, for uniform air  ow and temperature distribution. discharge louvre, for uniform air  ow and temperature distribution.

Auto fan speed For more information: www.daikin.eu Automatically selects the necessary fan speed to reach or maintain Fan speed steps the set temperature. Allows to select up to the given number of fan speed. Daikin Europe N.V. participates in the Eurovent Certified Performance programme for Liquid Chilling Packages and Individual  ap control logic Hydronic Heat Pumps, Fan Coil Units and Variable Refrigerant Flexible installation thanks to the possibility of easily closing When installed close to a heating device (e.g. replace or oven) Flow systems. Check ongoing validity of certificate: one  ap via the wired remote controller, to suit any new room and the set temperature is reached, the fan keeps on running to www.eurovent-certification.com con guration. Optional closure kits are available as well. have an even temperature throughout the whole house ECPEN18-500A Coanda e ect - cooling Grid eye sensor The present publication is drawn up by way of information only and does not constitute an offer binding upon The Coanda e ect optimises the air ow in cooling mode. By using The grid eye sensor determines the current room temperature and Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No specially designed  aps, a more focused air ow allows a better distributes air evenly throughout the room before switching to an express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its temperature distribution throughout the whole room. air ow pattern that directs warm or cool air to areas that need it. content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from Coanda e ect - heating or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. The Coanda e ect optimises the air ow in heating mode. By using Printed on non-chlorinated paper. Prepared by Schaubroeck specially designed  aps, a more focused air ow allows a better temperature distribution throughout the whole room.

133651_ECPEN_500A_v02.indd 1 28/02/18 07:42

48 Tools and platforms

Literature overview 50 Supporting tools, software and apps 52 TOOLS & PLATFORMS & TOOLS

49 Commercial market - literature overview

for professional network Solution guides:

Reference books:

Product VRV IV range i VRV IV i-series Keep looking Sky Air Water-to-air profiles: Detailed VRV IV you’ll never find me Main benefits, A-series heat pump VRV IV Our mission ater-to-air 360° efficiency standards and application examples Achieve the lowest Main benefits heat pump Detailed info on technologies and specs of VRV IV environmental using water as a heat source impact and specs VRV IV W-series, benefits. Main VRV IV heat pumps for indoor installation i-series product range application features and 207 116 examples, specs of VRV IV technical VRV IV heat recovery, heat pump, replacement and water cooled product range Introducing the new Sky Air A-series with VRV IV S-series ultra-efficient Bluevolution R-32 technology cale up your epectations system design Keep looking you’ll never find me Main benefits, background 206 application examples and specs of VRV IV 209

Compact VRV IV heat pumps S-series product range for residential and light commercial applications 208

Focus Replacement Infrastructure cooling

INUOU NT S O O P Clear installer benefits , C E E R L A B T

Technology I

A O

topics: I

N L E

Replacement R Infrastructure cooling solution why to choose Daikin for technology Clear installer benefits for installers of VRV replacement infrastructure cooling technology

› For server rooms, telecom shelters, laboratories, IT applications The quick and quality way of upgrading R-22 and R-407C systems 214 140

Real time clock Possibility to individually restrict menu Split, Sky Air, VRV, , functions/buttons Real time clock with auto update to daylight saving , Daikin Altherma time › Restrict some of all functions on the remote control to void misuse in e.g. hotels, shops, offices Wired Remote Control RTD modbus interface ProductSupports multiple languages Other features › English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish › Built-in back-up power. When a power failure occurs, and Polishr (BRC1E52A) all settings remain stored up to 48 hours

› English, German, Czech, Croation, Hungarian, › Backlight display Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian (BRC1E52B) Detailed info on BRC1E- Detailed info on RTD flyers: Modbus Specifications / Functions User friendly

Specifications BRC1E52A / BRC1E52B Dimensions (HxWxD) 3.120x120x19 mm40 remote control 52A/B remote control Interface controls and applications Display size (HxW) 43.2x68.85 mm LCD Type Full dot (160x255) Colour Fresh white Cover for operation part No RTD Max. wiring length 500m with contemporary Connectable indoor units All VRV® and Sky Air® indoor units

Functions BRC1E52A / BRC1E52B Set sensor behavior — design Temperature range limit — Energy saving Setback function — functions Set point auto reset — BRC1E52A/B Off timer — Multilingual display English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, Polishr English, German, Czech, Croation, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian Help menu — Room temperature display — Display Clock (time display) Real time clock with auto update to daylight saving time Backlight — Contrast adjustment — Weekly schedule timer 3 Timer Holiday function — Key lock — Access control Restrict menus Each menu individually Restrict buttons Each button individually (ON/OFF, operation mode selector, temperature adjustment, fan speed / air flow direction) Memory Built-in back-up power When a power failure occurs, all settings remain stored up to 48 hours

› Easy to use: all main functions directly accessible › Set up to 3 independent schedules, so the user can easily change the schedule himself throughout the Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor) › Easy commissioning: intuitive interface for advanced year (e.g. summer, winter, mid-season) menu settings › Real time clock with auto update to daylight saving FSC › Optimise your air conditioning system by activating a time series of energy saving functions (temperature range Integration of Daikin portfolio in BMS system via Modbus ECPEN15 - 306 180 · 11/14 limit, setback function, off timer, …) › Supports multiple languages The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No › Indoor unit control › Retail applications express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its › Keep track of your energy consumption with the › Possibility to individually restrict menu functions content and the products and services presented therein. Specifications are subject to change without prior notice. kWh indication showing an indicative electricity via 0~10 volt, dry contact › Hotel applications Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. consumption › When a power failure occurs all settings remain stored or resistance contact › IT applications

The present publication supersedes ECPEN12-306. Printed on non-chlorinated paper. up to 48 hours thanks to the built-in backup power › Heating interlock 306 › Alarm signal 308

Product Sky Air Catalogue VRV Catalogue Ventilation Catalogue catalogues: Detailed technical Detailed technical Detailed info on Sky Air VRV Ventilation Product catalogue 2017 information & benefits Product catalogue 2018 information & benefits of Product catalogue 2018 Ventilation products for professionals for professionals for professionals on Sky Air/Ventilation/ the VRV total solution Biddle Air Curtain/Control systems/AHU

R-32 IS AN INDUSTRY REVOLUTION. BE PART OF IT. Including THE BEST VISIT OUR BIM PARTNER new Minimum running costs, APPLICATION ErP FOR GREEN SUITE ON Modular L compliant Get ahead of competition maximum flexibility. BUILDING WWW.DAIKIN.EU/BIM Fresh air for the residential and commercial sector 2021 SUPPORT Fast installation, top reliability, Heat reclaim ventilation and air handling applications 100 perfect comfort. 200 203

50 Tools and platforms for your customers

Commercial Solutions Green Building Solutions Clear building owner/investor Green building Commercial solutions Daikin offers solutions for for small to large applications commercial applications solutions benefits why to choose Daikin for a green building, with emphasis on BREEAM 365-days climate comfort for every business 216 100

Sustainable design with Daikin HVAC-R systems

Reference catalogue Daikin commercial Hotel Solutions and industrial Hotel solutions Clear building owner/investor references for hotel owners benefits why to choose Daikin for a hotel Heating - air conditioning - hot water - ventilation - refrigeration - control 218 213

Ta Intelligent Touch Manager blet DCC601A51 Detailed benefits of Detailed benefits of DCC601A51

Control systems intelligent Intelligent Touch Intelligent Touch Manager Tablet Controller and Daikin Cloud Service Manager with cloud connection

Mini Building Management System 302 Your business at your fingertips 303

SPLIT, SKY AIR, VRV, CHILLERS Replacement technology Clear building owner/investor The phase-out period for R-22 is over. benefits of replacement Act now! technology

Avoid loss of business and replace your air conditioning system now! 215

Sky Air product leaflets VRV product leaflets Single page leaflet with the Single page leaflet with the Concealed floor standing Concealed unit main benefits and technical ceiling unit main benefits and technical FNQ-A, FXNQ-A with medium ESP specifications of each FBQ-D, FXSQ-A specifications of each individual individual Sky Air unit. Ideal for VRV unit. Ideal for quotations quotations

Designed to be concealed in walls Optimum comfort guaranteed no matter the Home leave length of ductwork or type of Home leave operation operation › Ideal for installation in offices, hotels and residential › Discretely concealed in the wall, leaving only the › Top efficiency in the market › Medium external static pressure up to 150Pa facilitates applications suction and discharge grilles visible › Automatic air flow adjustment function measures the using flexible ducts of varying lengths › Its low height enables the unit to fit perfectly beneath › Requires very little installation space as the depth is air volume and static pressure and adjusts it towards › Reduced energy consumption thanks to specially a window only 200mm Powerful mode the nominal air flow, whatever the length of duct, developed DC fan motor Powerful mode › High ESP allows flexible installation making installation easier and guaranteeing comfort. › Flexible installation, as the air suction direction can be Moreover, the ESP can be changed via the wired altered from rear to bottom suction remote control to optimize the supply air volume › Standard built-in drain pump increases flexibility and Multi tenant Multi tenant (FXSQ) › Slimmest unit in class, only 245mm installation speed (FXNQ-A) › Discretely concealed in the ceiling: only the suction › No optional adapter needed for DIII-connection, link and discharge grilles are visible your unit into the wider building management system › Low sound level

Technical documentation: TOOLS & PLATFORMS & TOOLS All latest Daikin catalogues are available in a convenient library on the internet: www.daikineurope.com/support-and-manuals/catalogues

51 www.daikineurope.com/ Supporting support-and-manuals/ tools, software and apps software-downloads

New web based Xpress selection software

Making selection easy, anytime, anywhere

›› Web & cloudbased access to your projects from ›› No need to do local installation anywhere, at any time… ›› No tool updates required ›› Platform (Windows, Mac, …) and hardware (always latest version available) (laptop, desktop, tablet) independent ›› Possibility to copy / share projects ›› Re-engineered GUI for maximum easy of use

Easy selection, anytime, anywhere

Main functions

Toolbox Working area

Detailed properties

Import / Export / Delete indoors

Easy editing of piping Intuitive interface

Clear wiring overview, easy to make control groups Clear overview of control groups and central controls

52 Other selection software

VRV Pro Ventilation Xpress

Enables VRV air conditioning systems to be Selection tool for ventilation devices (VAM, VKM). The engineered in a precise and economical way, taking selection is based on given supply/extract airflows into account the complex piping rules. Moreover, it (including fresh up and given ESP of supply/extract ensures optimum operating cycles and maximum ducting): energy efficiency. ›› Determines size of electrical heaters ›› Accurate heat load calculation ›› Visualisation of psychrometric chart ›› Precise selection based on peak loads ›› Visualisation of selected configuration ›› Energy consumption indication ›› Required field settings mentioned in the report

Webbased ASTRA selection NEW WAGO selection tool NEW for air handling units The WAGO Selection Tool is specifically designed to A powerful tool to select the right Air Handling Units select the optimal WAGO I/O system for your needs. for your needs. ›› 3D interface ›› Easy selection of WAGO materials ›› quick selection procedures ›› Material list creation ›› new print-out possibilities and report shapes ›› Time saving • Includes wiring schemes • Contains commissioning/preset data for TOOLS & PLATFORMS & TOOLS

53 Plug-ins and third-party software tools

Building Information Modelling www.daikin.eu/ (BIM) support bim

›› BIM improves efficiency of design and build phase ›› Daikin is among the first to supply a full library of BIM objects for its VRV products

VRV CAD 2D http://www. ›› Displays VRV pipe design on a Autocad 2D floorplan daikineurope. ›› Improves project management com/autocad/ ›› Accurately calculates the pipe dimensions and refnets index.jsp ›› Determines the outdoor unit size ›› Validates VRV pipe rules ›› Accounts for the extra refrigerant charge, including a max room concentration check

Energy simulation and design aid tools

Seasonal simulator

›› The Seasonal Simulator is an innovative software tool that calculates and compares potential seasonal efficiency ratings. ›› This user-friendly tool compares various Daikin

systems, annual power consumption, CO2 emissions, and much more, to present an accurate ROI calculation in a matter of minutes.

Psychrometrics diagram NEW

›› The Diagram Viewer demonstrates the changing properties of moist air. ›› With this tool, users can choose two points with specific conditions, plot them on the diagram and select actions to change the conditions, i.e. heat, cool and mix air.

54 Service tools

Error code app

Quickly know the meaning of fault codes, for each product family and the potential cause

D-Checker

D-checker is a software application used to record and monitor operation data of Daikin applied, split, Multi-split, Sky-air units, Daikin Altherma LT, , Hybrid, ZEAS, Conveni-pack & R410A Booster unit

Bluetooth adaptor NEW

Monitoring of Split, Sky Air and VRV data via any bluetooth device Diagnosis of the Bluetooth system possible: ›› No need to access the outdoor unit • Connects with D-Checker software (for laptops) • Connects with monitoring app (for tablets or smartphones) Computer with Bluetooth

VRV Service-Checker

›› Connected via F1/F2 bus to check multiple systems at the same time ›› Connection of external pressure sensors possible

Online support Internet

Find our solution for different applications: NEW Business portal Supermarket Technical ›› Experience our new extranet that Restaurant Hotel Store & Bank Industry thinks with you at my.daikin.eu shop ›› Find information in seconds Sport & via a powerful search Home Office Leisure ›› Customise the options so you see only info relevant for you ›› Access via mobile device or desktop my.daikin.eu

ON ›› Get more commercial details on our flagship THE products via our dedicated minisites ROAD AT ›› See our references CUSTOMERS

HOTEL PORTA FIRA PLATFORMS & TOOLS AT THE OFFICE

www.daikineurope.com/references

55 56 Technical drawings

ALB-RBS / LBS 58 VAM-J/FC 64 VKM-GB(M)

57 DRAWINGS TECHNICAL VIEW ALL ALB-LBS DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

ALB02RBS/LBS

CONDENSATE OUTLET 1/4”G

T IEW TT IEW

ELECTRIC SWITCH BOX

ALB03RBS/LBS

CONDENSATE TT IEW OUTLET 1/4”G

T IEW

ELECTRIC SWITCH BOX

58 VIEW ALL ALB-RBS DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

ALB04RBS/LBS

CONDENSATE OUTLET 1/4”G

T IEW

TT IEW

ELECTRIC SWITCH BOX

ALB05RBS/LBS

CONDENSATE OUTLET 1/4”G

T IEW TT IEW

ELECTRIC SWITCH BOX

59 DRAWINGS TECHNICAL VIEW ALL ALB-LBS DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

ALB06RBS/LBS

CONDENSATE OUTLET 1/4”G

T IEW

TT IEW

ELECTRIC SWITCH BOX

ALB07RBS/LBS

CONDENSATE OUTLET 1/4”G

T IEW

TT IEW

ELECTRIC SWITCH BOX

60 VIEW ALL ALB-RBS DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

ALB02RBS/LBS

The diagram shows the available external pressure for the duct system given an airflow. SFPv = Specific Fan Power (W/m3/s) The SFPv curves are referring to the complete unit. Moreover, it includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater.

Nominal working point

ALB03RBS/LBS

The diagram shows the available external pressure for the duct system given an airflow. SFPv = Specific Fan Power (W/m3/s) The SFPv curves are referring to the complete unit. Moreover, it includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater.

Nominal working point

61 DRAWINGS TECHNICAL VIEW ALL ALB-LBS DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

ALB04RBS/LBS

The diagram shows the available external pressure for the duct system given an airflow. SFPv = Specific Fan Power (W/m3/s) The SFPv curves are referring to the complete unit. Moreover, it includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater.

Nominal working point

ALB05RBS/LBS

The diagram shows the available external pressure for the duct system given an airflow. SFPv = Specific Fan Power (W/m3/s) The SFPv curves are referring to the complete unit. Moreover, it includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater.

Nominal working point

62 VIEW ALL ALB-RBS DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

ALB06RBS/LBS

The diagram shows the available external pressure for the duct system given an airflow. SFPv = Specific Fan Power (W/m3/s) The SFPv curves are referring to the complete unit. Moreover, it includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater.

Nominal working point

ALB07RBS/LBS

The diagram shows the available external pressure for the duct system given an airflow. SFPv = Specific Fan Power (W/m3/s) The SFPv curves are referring to the complete unit. Moreover, it includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater.

Nominal working point

63 DRAWINGS TECHNICAL VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM150FC

VAM150FA Maintenance space for the heat exchange elements, the air filters and fans Switch box

Ceiling hook Inspection hole 4-14x40 oval hole 285 Ø 450 269 Supply air fan

60 0 Maintenance over 149 104 120.3 120~25 0 0 2 7 6

SA OA 16 4 Supply air to room 12 4 Fresh air from outdoors 28 8 50 9 56 0

28 8 (Outdoor air) 12 4 16 4 RA EA Return air from room Exhaust air to outdoors 8 Sealing 8 Sealing 0

120 104 718 2 149 Damper plate Exhaust air fan (Maintenance cover) Exhaust spacer (Switch box) 145 760 145 7 9 20 0 Ø Ø

Heat exchange elements Air filters

NOTE 1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.

3TW27874-1

VAM250FC VAM250FA Maintenance space for the heat exchange elements, the air filters and fans Switch box

Ceiling hook Inspection hole 285 Ø 450 4-14x40 oval hole 269 Supply air fan

149 60 0 Maintenance over

120~25 0 104 120.3 0 2 7 6

SA OA 16 4 Supply air to room 12 4 Fresh air from outdoors 28 8 50 9 56 0 28 8 (Outdoor air) 12 4 16 4 RA EA Return air from room Exhaust air to outdoors 8

Sealing 8 Sealing 0 120 104 718 2 149 Damper plate Exhaust air fan (Maintenance cover) (Switch box) 145 760 145 7 9 20 0 Ø Ø

Heat exchange elements Air filters

NOTE 1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.

3TW27884-1

64 VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM350-500J

VAM350-500J

Ceiling hook Damper panel 304305.8 Exhaust air fan 4 - 12 x 40mm oblong hole 10 284.8 10 1045 112112.3

112122.3 22 Sealing material 6 Sealing material RA Return air from room

EA 6 121376.8 292 291 . Exhaust air to outdoors 2 417 126 4

4 Room air 161732.8

Exhaust air 126 . 899 834 4 161732.8 866 891 899 . Sealing material 891 . SA 125 125 . 417 121376.8 8 Supply air to room 291 290 . Supply air OA Supply air fan Fresh outdoor air Outdoor air Sealing material

6 4 190 22 191 .

112122.3 0 112122.3 3 0

Sealing material -

Sealing material ≥675 20 0

475 Inspection hole

Maintenance space for the air lters, heat exchangers and fans Switch bo x 900

Heat exchanger

7884 11131101 7884

6 6

Switch box 213 197 Ø Ø

Maintenance cover Air lter N o tes : 1. To allow for the inspection of the air lters, heat exchangers, and fans, be sure to provide the inspection hole. 3D112815B

VAM650J VAM650J

Ceiling hook 368 Exhaust air fan 4 - 12 x 40mm oblong hole Damper panel

1266

154 22 Sealing material 154 Sealing material

RA EA Return air from room Exhaust air to outdoors 272 Exhaust air 222 Room air 162 211 941 920

(491) 211 949 162 493

Sealing material 220

272 SA Supply air to room OA Supply air Fresh outdoor air Supply air fan

186 Sealing material Outdoor air 22 154

154 Sealing material 0 00 3 0 7

- Sealing material ≥ 200

500 Inspection hole

Maintenance space for the air lters, heat exchangers and fans Switch box 1100

Heat exchanger

83 1354 83

Switch box Ø 262 Ø 245

Maintenance cover Air lter Notes 1.To allow for the inspection of the air lters, heat exchangers, and fans, be sure to provide the inspection hole. 3D112816B

65 DRAWINGS TECHNICAL VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM800-1000J VAM800-1000J Ceiling hook 368 4 - 12 x 40mm oblong hole Damper panel

Exhaust air fan 1266

154 154 Sealing material 22 6

Sealing ma terial RA

EA Return air from room 162

Exhaust air to outdoors 399 239

212 (606 ) Room air 1204 1197 1172 (628) 162 Sealing mate rial 207 SA 389 Supply air to room

OA Supply air 212 Fresh outdoor air Sealing material

Outdoor air 6 Supply air fan 192 22 154 154

Sealing material 300

Sealing ma terial ≥850 200 -

650 Inspection hole

Maintenance space for the air lters, heat exchangers and fans

Switch box 1100

Heat exchange r

83 1354 83

Sealing mate rial Ø 262 Ø 245

Maintenance cover Switch box Air lter Notes 1.To perform maintenance on the air lter, it is required to provide a service access panel. 3D112817C

VAM1500-2000J VAM1500-2000J

Ceiling hook Damper panel 731 (2x) Exhaust air fan 4 - 14 x 40mm oblong hole 1266 (4x) O p ti o n E K P L EN 200 384 150 150 345 20 Sealing material 6 Sealing material Sealing material RA

EA ) 4 x (

38 0 Return air from room Exhaust air to outdoors 395 250 Room air (577) 1219 1172 1198

Exhaust air (599) 218 SA 348 OA Supply air to room Fresh outdoor air Supply air Outdoor air

198 20 (2x) Supply air fan

345 150 150 384 Sealing material 0 Sealing material 3 0 - Inspection hole Sealing material ≥850 20 0 650

Maintenance space for the air lters, heat exchangers and fans Switch box 1100 Heat exchanger

130 261 1354 261 130

26 Sealing material

Option KRP2A51 Mounting 405 621 Ø 330 Ø 350 plate Switch box

Option BRP4A50A 24 (10) Air lter Maintenance cover Notes: 1. To allow for the inspection of the air lters, heat exchangers, and fans, be sure to provide the inspection hole. 3D112818B

66 VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM150FC

m

m

ltrahigh

m

igh External static pressure [Pa] ow m ipe length

Air flow rate [m³/h]

otes he fan speeds are alid for power supply

67 DRAWINGS TECHNICAL VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM250FC

ltrahigh ipe length

igh m

External static pressure [Pa] ow m

m

m

Air flow rate [m³/h]

otes he fan speeds are alid for power supply

VAM350JVAM350J

250 Ultra-high speed 200

[Pa] 300

[Pa] 250 150 250 200 200 pressure

pressure 100 150 150

100 static

static UH15 100 50 50 50 UH8 External Ø200

External UH1 0 Duct lenght 0 450 150150 100 150 200 250 300 350 400 450 150 200 250 300 350 400

Air ow rate [m/h] Air ow rate [m/h] Low speed

High speed [Pa]

[Pa] 200 200

150 150 pressure

pressure 100 100 H15 static 50

static 50

H1 H8 L1($" L15 0 0 L8()" 150 200 250 300 350 400 450 100 150 200 250 300 350 400 450 External External Air ow rate [m/h] Air ow rate [m/h]

Legend Notes L1 = Low speed lower limit 1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L8 = Low speed factory setting (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). L15 = Low speed upper limit EA= Exhaust air H1 = High speed lower limit Ultra-high speed OA= Outdoor air H8 = High speed factory setting High speed RA = Room air H15 = High speed upper limit UH1 = Ultra-high speed lower limit SA = Supply air Low speed UH8 = Ultra-high speed factory setting 2. Measured according to ·JIS B 8628 - 2003· UH15 = Ultra-high speed upper limit 3D113493

68 VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM500JVAM500J

250 200m

UH15 Ultra-high speed 200 [Pa] UH8 160m

[Pa] 250 H15

150 200

pressure H8 120m UH1 L15 pressure 150

static 100 80m 100 H1 static UH15 L8 50 UH8

External 50 40m UH1

External 0 L1 Ø200 250 300 350 400 450 500 550 600 Duct length 0 Air ow rate [m³/h] 150 200 250 300 350 400 450 500 550 600 Air ow rate [m³/h] High speed Low speed [Pa]

200 [Pa] 200

150 150 pressure pressure 100 100 static static 50 50 H15 L15 L1 0 H1 H8 0 External L8

200 250 300 350 400 450 500 550 600 External 150 200 250 300 350 400 450 500

Air ow rate [m³/h] Air ow rate [m³/h] Legend

Notes L1= Low speed lower limit 1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L8= Low speed factory setting (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). L15= Low speed upper limit EA= Exhaust air H1= High speed lower limit OA = Outdoor air Ultra-high speed H8= High speed factory setting H15= High speed upper limit RA = Room air High speed SA = Supply UH1=Ultra-high speed lower limit 2. Measured according to ·JIS B 8628 - 2003· Low speed UH8= Ultra-high speed factory setting UH15= Ultra-high speed upper limit 3D113494

VAM650J VAM650J 250

200 UH15 Ultra-high speed UH8 200m 250 H15 150 H8 160m 200 UH1 L15 100 120m 150 H1 800m L8 100 UH15 External static pressure [Pa] External pressure static 50 40m 50 UH8 L1 Ø250 UH1 0 Duct Length [Pa] External pressure static 0 250 350 450 550 650 750 350 450 550 650 750 Air ow rate [m³/h] Air ow rate [m³/h]

High speed Low speed 250 200 200 150 150 100 100 50 50 H15 L15 H1 H8 L1

External static pressure [Pa] External pressure static 0 L8

External static pressure [Pa] External pressure static 0 250 350 450 550 650 750 250 350 450 550 650 750 Air ow rate [m³/h] Air ow rate [m³/h] Legend Notes L1= Low speed lower limit 1. The fan curves are determined with 1/3 of the ESP on the L8= Low speed factory setting outdoor side (EA & OA), and 2/3 of the ESP on the indoor side (RA & SA). Ultra-high speed L15= Low speed upper limit EA = Exhaust air H1= High speed lower limit OA = Outdoor air High speed H8= High speed factory setting RA = Room air H15= High speed upper limit SA = Supply air UH1= Ultra-high speed lower limit 2. Measured according to JIS B 8628 - 2003 Low speed UH8= Ultra-high speed factory setting UH15= Ultra-high speed upper limit 3D113495A

69 DRAWINGS TECHNICAL VIEW ALL VAM-FC TECHNICAL VIEW ALL VAM-J TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM800J

VAM800J 300 UH15 Ultra-high speed 250 350 H15 180m 300 200 UH8 150m 250 150 L15 120m H8 200 UH1 90m UH15 100 150 H1 L8 60m 100

External pressure[PA] static 50 30m L1 External pressure[PA] static 50 UH8 Ø250 UH1 0 Duct length 0 300 400 500 600 700 800 900 400 500 600 700 800 900 Air ow rate [m/h] Air ow rate [m/h] High speed Low speed 300 250

250 200 200 150 150 100 100 H15

50 50

External pressure[PA] static L15 External pressure[PA] static H1 L1 0 H8 0 L8 400 500 600 700 800 900 300 400 500 600 700 800 900 Air ow rate [m/h] Air ow rate [m/h]

Legend Notes L1= Low speed lower limit L8= Low speed factory setting 1. The fan curves are determined with ·1/3· of the ESP on the outdoor side L15= Low speed upper limit (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·). Ultra-high speed H1= High speed lower limit EA = Exhaust air H8= High speed factory setting OA = Outdoor air High speed H15= High speed upper limit RA= Room air UH1= Ultra-high speed lower limit SA = Supply air UH8= Ultra-high speed factory setting Low speed 2. Measured according to ·JIS B 8628 - 2003· UH15= Ultra-high speed upper limit 3D112837

VAM1000J

300 Ultra-high speed UH15 150m 350 250 UH8 120m 300 200 H15 250 UH1 90m H8 150 200 L15 External static [Pa] pressure H1 150 100 UH15

L8 External static [Pa] pressure 100 50 30m 50 UH8 L1 Ø250 UH1 0 Duct lenght 0 400 500 600 700 800 900 1000 1100 600 700 800 900 1000 1100 Air ow rate [m/h] Air ow rate [m/h]

High speed High speed 300 250

250 200 200 150 150 100 100 H15 50 50 L15 External static pressure [Pa] External pressure static External static pressure [Pa] External pressure static L1 H1 H8 0 0 L8 500 600 700 800 900 1000 400 500 600 700 800 900 Air ow rate [m/h] Air ow rate [m/h] Notes Legend 1.The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·), L1 = Low speed lower limit and ·2/3· of the ESP on the indoor side (·RA & SA). LB = Low speed factory setting L15 = Low speed upper limit EA= Exhaust air Ultra-high speed H1 = High speed lower limit OA = Outdoor air High speed H8 = High speed factory setting RA= Room air Low speed H15 = High speed upper limit SA= Supply air UH1 = Ultra-high speed lower limit UH8 = Ultra-high speed factory setting 2. Measured according to ·JIS B 8628 - 2003· UH15 = Ultra-high speed upper limit 3D112832 70 VIEW ALL VAM-J TECHNICAL VIEW ALL VAM-FC TECHNICAL DRAWINGS ON MY.DAIKIN.EU DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VAM1500J VAM1500J 300

UH15 250

[Pa] Ultra-high speed 350 H15 200 180m 300

UH8 [Pa] 150m pressure 150 250 H8 L15 120m

static UH1 200 100 90m pressure UH15 H1 150 60m

L8 static 50

External 100 30m L1 2xØ250 0 Duct length 50 UH8

700 900 1100 1300 1500 1700 External UH1 0 Air ow rate [m³/h] 700 900 1100 1300 1500 1700 Air ow rate [m³/h] High speed Low speed 300 250

250 [Pa] 200 [Pa]

200 150 150 pressure pressure 100 100 H15 static 50 L15 50

H8 External static External 0 H1 0 L1 L8 700 900 1100 1300 1500 1700 700 900 1100 1300 1500 Air ow rate [m³/h] Air ow rate [m³/h]

Legend Notes L1 = Low speed lower limit 1. The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·),and ·2/3· of the ESP on the indoor side (·RA & SA·). L8 = Low speed factory setting EA = Exhaust air L15 = Low speed upper limit OA = Outdoor air H1 = High speed lower limit RA = Room air H8 = High speed factory setting SA = Supply air H15 = High speed upper limit 2 .Measured according to ·JIS B 8628 - 2003· Ultra-high speed UH1 = Ultra-high speed lower limit High speed Low speed UH8 = Ultra-high speed factory setting UH15 = Ultra-high speed upper limit 3D112838

VAM2000J VAM2000J 300 150m UH15 250 Ultra-high speed 120m 350 UH8 H15 200 [Pa] 300 UH1 90m 250 H8 150 L15 pressure 200 H1 60m 150 100 static L8 UH15 100 30m 50 50 L1 External UH8 2xØ250 External static pressure [Pa] Duct length 0 UH1 0 1200 1400 1600 1800 2000 2200 800 1000 1200 1400 1600 1800 2000 2200 Air ow rate [m³/h] Air ow rate [m³/h] High speed Low speed 300 250

250 [Pa]

[Pa] 200

200 150 pressure

pressure 150 100 static 100 static H15 50 50

External L15

External H8 0 H1 0 L1 L8 1000 1200 1400 1600 1800 2000 800 1000 1200 1400 1600 1800 Air ow rate [m³/h] Air ow rate [m³/h] Legend Notes L1 = Low speed lower limit 1. The fan curves aredetermined with ·1/3· of the ESP on the outdoor side (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA &SA·). L8 = Low speed factory setting EA=Exhaust air L15 = Low speed upper limit OA=Outdoor air H1 = High speed lower limit RA=Room air H8 = High speed factory setting SA=Supply air H15 = High speed upper limit 2. Measured according to ·JIS B 8628 - 2003· UH1 = Ultra-high speed lower limit Ultra-high speed UH8 = Ultra-high speed factory setting High speed UH15 = Ultra-high speed upper limit Low speed 3D112839

71 DRAWINGS TECHNICAL VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM50GB VKM50GB

Air discharge (locally procured) Air suction grille (locally procured) Heat insulator (locally procured)

EA Heat insulated (Exhaust air to outdoors) Branch duct (locally procured) (locally procured) Round shape hood (locally procured) OA (Fresh air to outdoors) Control box Flexible duct Air discharge grille Inspection Inspection (locally procured) (locally procured) Maintenance space for the heat exchanger hatch hatch elements the air filters and fans More than 600

360 (in case of □ 450 inspection hatch) 140 (in case of □ 600 inspection hatch)

Refrigerant piping (Gas pipe) (Ø 12.7 flare connection) A gradient of more than 1/30 Refrigerant piping (Liquid pipe) (Ø 6.4 flare connection) Ø 200 Nominal diameter (locally procured)

OA (Fresh air to outdoors) EA (Exhaust air to outdoors) Suspention bolt (locally procured) Sloping downwards at Inspection hatch RA SA a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES 1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be inspected and serviced.) 2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to prevent dew condensation.(Material: glass wool of 25mm thick) 3. Do not turn the unit upside down. 4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation. 5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming. 6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory). 7. In areas where freezing may occur, always take steps to prevent the pipes from freezing. 8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air filter is very dirty. 3D083014

72 VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM50GBM VKM50GBM

Air discharge grille (locally procured) Air suction grille (locally procured) Heat insulator (locally procured)

Heat insulated EA (locally procured) (Exhaust air to outdoors) Branch duct

Round shape hood (locally procured) (locally procured) OA (Fresh air to outdoors) Control box Flexible duct Air discharge grille Inspection Inspection (locally procured) (locally procured) Maintenance space for the heat exchanger hatch hatch

elements the air filters, fans and humidifier More than 600

360 (in case of □ 450 inspection hatch) 140 (in case of □ 600 inspection hatch) Water supply shut-off valve (locally procured) Cistern tank Drain valve (locally procured) Refrigerant piping (Gas pipe) (Ø 12.7 flare connection) A gradient of more than 1/30 Strainer Refrigerant piping (Liquid pipe) (locally procured) (Ø 6.4 flare connection) Ø 200 Nominal diameter (locally procured)

OA (Fresh air to outdoors) EA (Exhaust air to outdoors) □ 450 - 600 Suspention bolt Sloping downwards at Inspection hatch (locally procured) RA SA a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES 1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be inspected and serviced.) 2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to prevent dew condensation. (Material: glass wool of 25mm thick) 3. Do not turn the unit upside down. 4. Use city water or clean water. Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the inspection. 5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping. 6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 ) 7. Make sure the supply water is between 5°C and 40°C in temperature. 8. Insulate the water supply piping to prevent condensation from forming. 9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation. 10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming. 11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0°C. 12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory). 13. In areas where freezing may occur, always take steps to prevent the pipes from freezing. 14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air filter is very dirty. 15. Feed clean water. If the supply water is hard water, use a water softener because of short life. Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the supply water conditions of hardness: 400 mg/L.) 3D083011

73 DRAWINGS TECHNICAL VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM80GBVKM80GB

Air suction grille Air discharge grille Heat insulator (locally procured) (locally procured) (locally procured)

Heat insulated EA Branch duct (locally procured) (Exhaust air to outdoors) (locally procured) Round shape hood (locally procured) OA Silencer (Fresh air to outdoors) (locally procured) Control box Flexible duct Air discharge grille (locally procured) (locally procured) Inspection Inspection Maintenance space for the heat exchanger hatch hatch

elements the air filters and fans More than 600

360 (in case of □ 450 inspection hatch) 140 (in case of □ 600 inspection hatch)

Refrigerant piping (Gas pipe) (Ø 12.7 flare connection) A gradient of Ø 250 more than 1/30 Refrigerant piping (Liquid pipe) Nominal diameter (Ø 6.4 flare connection) (locally procured)

OA (Fresh air to outdoors) EA (Exhaust air to outdoors) □ 450 - 600 Suspention bolt Sloping downwards at Inspection hatch (locally procured) RA SA a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES 1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be inspected and serviced.) 2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to prevent dew condensation. (Material: glass wool of 25mm thick) 3. Do not turn the unit upside down. 4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation. 5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming. 6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory). 7. In areas where freezing may occur, always take steps to prevent the pipes from freezing. 8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air filter is very dirty.

3D083015

74 VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM80GBM VKM80GBM

Air suction grille Air discharge grille Heat insulator (locally procured) (locally procured) (locally procured)

Heat insulated EA Branch duct (locally procured) (Exhaust air to outdoors) (locally procured) Round shape hood (locally procured) OA (Fresh air to outdoors) Silencer (locally procured) Control box Flexible duct Air discharge grille (locally procured) (locally procured) Inspection Inspection Maintenance space for the heat exchanger hatch hatch

elements the air filters, fans and humidifier More than 600

360 (in case of □ 450 inspection hatch) 140 (in case of □ 600 inspection hatch) Water supply shut-off valve (locally procured) Cistern tank Drain valve (locally procured) Refrigerant piping (Gas pipe) (Ø 12.7 flare connection) A gradient of more than 1/30 Strainer Refrigerant piping (Liquid pipe) (locally procured) (Ø 6.4 flare connection) Ø 250 Nominal diameter (locally procured)

OA (Fresh air to outdoors) EA

(Exhaust air to outdoors) Suspention bolt 450 - 600 □ (locally procured) Sloping downwards at Inspection hatch RA SA a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES 1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be inspected and serviced.) 2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to prevent dew condensation. (Material: glass wool of 25mm thick) 3. Do not turn the unit upside down. 4. Use city water or clean water. Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the inspection 5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping. 6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 ) 7. Make sure the supply water is between 5°C and 40°C in temperature. 8. Insulate the water supply piping to prevent condensation from forming. 9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation. 10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming. 11. Install in a location where the air around the unit or taken into the umidifier will not drop below 0°C. 12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory). 13. In areas where freezing may occur, always take steps to prevent the pipes from freezing. 14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air filter is very dirty. 15. Feed clean water. If the supply water is hard water, use a water softener because of short life. Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the supply water conditions of hardness: 400 mg/L.)

3D083012

75 DRAWINGS TECHNICAL VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM100GBVKM100GB

Air suction grille Air discharge grille Heat insulator (locally procured) (locally procured) (locally procured)

Heat insulated EA Branch duct (locally procured) (Exhaust air to outdoors) (locally procured) Round shape hood (locally procured) OA (Fresh air to outdoors) Silencer (locally procured) Control box Flexible duct Air discharge grille (locally procured) (locally procured) Inspection Inspection Maintenance space for the heat exchanger hatch hatch

elements the air filters and fans More than 600

360 (in case of □ 450 inspection hatch) 140 (in case of □ 600 inspection hatch)

Refrigerant piping (Gas pipe) (Ø 12.7 flare connection) A gradient of more than 1/30 Refrigerant piping (Liquid pipe) (Ø 6.4 flare connection) Ø 250 Nominal diameter (locally procured)

OA (Fresh air to outdoors) EA (Exhaust air to outdoors) □ 450 - 600 Suspention bolt Sloping downwards at Inspection hatch (locally procured) RA SA a gradient of the 1/100 (locally procured) (Return air from room) (Return air from room)

NOTES

1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters heat exchange elements, and fans can easily be inspected and serviced.) 2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water, also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to prevent dew condensation. (Material: glass wool of 25mm thick) 3. Do not turn the unit upside down. 4. Make sure to install drain piping, and insulate drain piping to prevent dew condensation. 5. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming. 6. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory). 7. In areas where freezing may occur, always take steps to prevent the pipes from freezing. 8. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air filter is very dirty.

3D083016

76 VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM100GBM VKM100GBM

Air suction grille Air discharge grille Heat insulator (locally procured) (locally procured) (locally procured)

Heat insulator EA Branch duct (locally procured) (Exhaust air to outdoors) (locally procured) Round shape hood (Locally procured) OA Silencer (Fresh air from outdoors) (locally procured) Control box Flexible duct Air discharge grille (locally procured) (locally procured) Inspection Inspection Maintenance space for the heat exchanger hatch hatch

elements the air fans and More than 600

360 (in case of □ 450 inspection hatch) 140 (in case of □ 600 inspection hatch) Water supply shut-off valve Cistern tank (locally procured) Drain valve (locally procured) Refrigerant piping (Gas pipe) A gradient of (Ø 12.7 connection) more than 1/30 Strainer Refrigerant piping (Liquid pipe) (accessory) (Ø 6.4 connection) Ø 250 Nominal diameter (locally procured)

OA (Fresh air from outdoors) EA (Exhaust air to outdoors) Suspension bolt □ 450 • 600 Sloping downwards at a Inspection hatch (locally procured) RA SA gradient of the 1/100 (Return air to room) (locally procured) (Return air from room)

NOTES 1. Leave space for servicing the unit and include inspection hatch. (Always open a hole on the side of the control box so that the air filters, heat exchange elements, fans and humidifier elements can easily be inspected and serviced.) 2. Install the two outdoor ducts with down slope (slope of 1/30 or more) to prevent entry of rain water. Also, provide insulation for three ducts (outdoor ducts and indoor supply air duct) to prevent dew condensation. (Material: glass wool of 25mm thick) 3. Do not turn the unit upside down. 4. Use city water or clean water. Include water supply piping with strainer, a water supply shut-off valve, and a drain valve (both locally procured) somewhere along the water supply piping that can be reached from the inspection. 5. It is impossible to connect the water supply piping directly to public piping. Use a cistern tank (of the approved type), if you need to get your water supply from public piping. 6. Make sure the supply water 0.02MPa to 0.49MPa (0.2 kg/cm2 to 5 kg/cm2 ) 7. Make sure the supply water is between 5°C and 40°C in temperature. 8. Insulate the water supply piping to prevent condensation from forming. 9. Make sure to install drain piping, and insulate drain piping to prevent dew condensation. 10. Keep the drain pipe short and sloping downwards at a gradient of at least 1/100 to prevent air from forming. 11. Install in a location where the air around the unit or taken into the humidifier will not drop below 0°C. 12. Do not use a bent cap or a round hood as the outdoor hood if they might get rained on directly (we recommend using a deep hood) (optional accessory). 13. In areas where freezing may occur, always take steps to prevent the pipes from freezing. 14. Do not place something which shouldn’t get wet at the below of this unit. The dew would fall at following case, where humidity is 80% more, or the exit of drain socket is choked up, or the air filter is very dirty. 15. Feed clean water. If the supply water is hard water, use a water softener because of short life. Life of humidifying element is about 3 years (4,000 hours), under the supply water conditions of hardness: 150 mg/L. (Life of humidifying element is about 1 years (1500 hours), under the supply water conditions of hardness: 400 mg/L.)

3D083013

77 DRAWINGS TECHNICAL VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM50GB VKM50GB –––––– 50Hz, 220V-240V Exchange efficiency Operating air flow rate range (%)

Temperature exchange efficiency

Enthalpy exchange efficiency (heating) Operating air flow rate range Operating air flow rate range Operating air flow rate range

Enthalpy exchange efficiency (cooling)

ø200 Pipe length

Ultra High

High

External static pressure (Pa) Low External static pressure (Pa)

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 2) Rated point: ● Mode no. : 19(29) ┌ ┌ 3) The characteristic of each tap becomes a setup of the First code: (Supply 2 ┘Exhaust 3 ┘) characteristic of the same code number. Second code no. : 07 3D082904

VKM50GBM VKM50GBM –––––– 50Hz, 220V-240V Exchange efficiency Operating air flow rate range (%)

Temperature exchangeVKM50GBM efficiency

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling) Operating air flow rate range Operating air flow rate range Operating air flow rate range ø200 Pipe length

Ultra High

High External static pressure (Pa)

Low External static pressure (Pa)

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 Mode no. : 19(29) 2) Rated point: ● First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the 3D082901 Second code no. : 07 ┘ ┘ characteristic of the same code number.

78 VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM80GB VKM80GB

–––––– 50Hz, 220V-240V Exchange efficiency Operating air flow rate range (%) Operating air flow rate range Operating air flow rate range Operating air flow rate range

Temperature exchange efficiency

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling)

Ultra High

High ø250 Pipe External static pressure (Pa)

External static pressure (Pa) length

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 Mode no. : 19(29) 2) Rated point: ● First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the 3D082905 Second code no. : 07 ┘ ┘ characteristic of the same code number.

VKM80GBM VKM80GBM –––––– 50Hz, 220V-240V Exchange efficiency Operating air flow Operating air flow rate range Operating air flow rate range Operating air flow rate range (%) rate range

VKM80GBM

Temperature exchange efficiency

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling)

Ultra High ø250 Pipe External static pressure (Pa)

length External static pressure (Pa) High

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 Mode no. : 19(29) 2) Rated point: ● First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the Second code no. : 07 ┘ ┘ characteristic of the same code number. 3D082902

79 DRAWINGS TECHNICAL VIEW ALL VKM-GB(M) TECHNICAL DRAWINGS ON MY.DAIKIN.EU Detailed technical drawings

VKM100GB VKM100GB –––––– 50Hz, 220V-240V Exchange efficiency Operating air flow rate range (%)

Operating air flow rate range Operating air flow rate range Operating air flow rate range

Temperature exchange efficiency

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling)

ø250 Pipe length Ultra High External static pressure (Pa) High External static pressure (Pa)

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 Mode no. : 19(29) 2) Rated point: ● First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the 3D082906 Second code no. : 07 ┘ ┘ characteristic of the same code number.

VKM100GBM

VKM100GBM –––––– 50Hz, 220V-240V Exchange efficiency (%)

Operating air flow rate range

Operating air flow rate range Operating air flow rate range Operating air flow rate range VKM100GBM Temperature exchange efficiency

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling)

ø200 Pipe length Ultra High External static pressure (Pa) High External static pressure (Pa)

Low

Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Air flow rate[m³/h] Low High Ultra High

[Reading of Performance Characteristics]

1) For example: 19(29)- -07 Mode no. : 19(29) 2) Rated point: ● First code: (Supply ┌ 2 Exhaust ┌ 3 ) 3) The characteristic of each tap becomes a setup of the Second code no. : 07 ┘ ┘ characteristic of the same code number. 3D082903

80 Notes

81 DRAWINGS TECHNICAL Notes

82 83 Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Publisher)

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented ECPEN19-203 12/18 therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

Printed on non-chlorinated paper.