List of References for „Flocformer“ Updated: 01.09.2015
Total Page:16
File Type:pdf, Size:1020Kb
List of references aquen aqua-engineering GmbH List of references for „FlocFormer“ Updated: 01.09.2015 Built-in FlocFormers on sewage works Company Installed FlocFormer Germany Stadtentwässerungswerke Lindau (B), Bavaria FlocFormer 3L (population: 25,000) Wasser- u. Bodenverband Wahn, Cologne, Two FlocFormer 4L Northrhine-Westphalia (population: 92,000) Stadtentwässerungsbetriebe Cologne AöR, FlocFormer 5L Northrhine-Westphalia, sewage works Cologne-Langel (population: 120,000) Sewage works Rüsselsheim, Hesse FlocFormer 5L (population: 60,200) EURAWASSER Betriebsführungsgesellschaft mbH, FlocFormer 5L sewage works Goslar, Lower Saxony (population: 40,700) Samtgemeinde Oberharz, sewage works Innerstetal, FlocFormer 3L Langelsheim, Lower Saxony (population: 11,900) aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 1 List of references aquen aqua-engineering GmbH Wasserver- und Entsorgunggesellschaft Kreiensen FlocFormer 3L mbH, sewage works Kreiensen, Lower Saxony (population: 2,500) Stadtentwässerungsbetriebe Cologne AöR, FlocFormer 4L Northrhine-Westphalia, sewage works Weiden (population: 88,000) Stadtentwässerungsbetriebe Cologne AöR, FlocFormer 4L Northrhine-Westphalia, sewage works Rodenkirchen (September 2015) (population: 88,000) Infraserv GmbH, Industriepark Höchst 7 FlocFormer 7L Frankfurt (population: 1,000,000; industrial sewage) Switzerland Biorender AG, Münchwilen, Thurgau FlocFormer 3L (population: 4,900) Japan Shimizu 2 FlocFormer 3L (population: 350.000) Indonesia PT Gudang Garam Tbk., Surabaya-Indonesia FlocFormer 4L China Dalian Yooqi Water Treatment Technology Co., Ltd. FlocFormers aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 2 List of references aquen aqua-engineering GmbH Realized pilot tests on sewage works Company Dewatering unit Type of sludge Ambition Result Germany Entsorgungsbetriebe Stadt Konstanz, Decanter Digested sludge Increase of dry mass Increase of dry mass content Baden-Württemberg content about 2% (population: 280,000) Retrenchment of Retrenchment of polymer: 25% Pilot test of FlocFormer 3L polymer Erftverband, sewage works Kenten Decanter Digested sludge Increase of dry mass Increase of dewatering Northrhine-Westphalia content performance from 26,33% TR to (population: 60,000) Retrenchment of 27,55% TR ≙ 5% polymer Retrenchment of polymer: 20% Pilot test of FlocFormer 5L Anklam Bioethanol GmbH, Decanter Digestate Increase of dry mass reduction of suspended solids Mecklenburg Western Pomerania content in centrifuge effluent of 50% (population: 12,930) Pilot test of FlocFormer 3L Sewage works Neuss-Ost, Decanter Digested sludge Increase of dry mass Increase of dry mass content Northrhine-Westphalia content about 1-3% (population: 151,000) Pilot test of FlocFormer 5L Stadtentwässerungswerke Lindau (B), Decanter Digested sludge Increase of dry mass Retrenchment of polymer Bavaria content about from 18 kg/t to (population: 60,000) Retrenchment of 11,2 kg/t ≙ 35% polymer Increase of dry mass content Pilot test of FlocFormer 3L from 20,67 to 23,35 (2,68%) ≙ 13% aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 3 List of references aquen aqua-engineering GmbH Sewage works Bremen/Farge Decanter Digested sludge Increase of dry mass Increase of dry mass content (population: 160,000) content from 22,6% to 26,59% (3,9%) ≙ 17% Pilot test of FlocFormers 5L Tönnies Lebensmittel GmbH & Co. KG, Decanter Municipal digested Increase of dry mass Increase of dry mass content sewage works Rheda-Wiedenbrück, sludge content from 21,33% to 23,62% Northrhine-Westphalia (+ 2%) ≙ 10% (population: 46,850) Clean centrifuge effluent Pilot test of FlocFormer 3L Urban drainage Achim, Lower Saxony Decanter Municipal digested Increase of dry mass Increase of dry mass content (population: 42,000) sludge content from 21,13% to 23,19% (+ 2 %) Reduction of ≙ 10% Pilot test of FlocFormer 3L phosphor in Reduction of phosphor about centrifuge effluent - 27% Sewage works Ratekau, Decanter Digested sludge Increase of dry mass Increase of dry mass content Schleswig-Holstein content from 22,15% to 25,32% (+ 3 %) (population: 50,000) ≙ 14% Pilot test of FlocFormer 3L Sewage works Winterhausen, Screen filter press Digested sludge Increase of dry mass Increase of dry mass content Bavaria content from 17,45% to 20,49% (+ 3 %) (population: 95,000) ≙ 17% Pilot test of FlocFormer 3L aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 4 List of references aquen aqua-engineering GmbH e4 Umwelt & Service GmbH Decanter Digested sludge Increase of dry mass Increase of dry mass content Dissen, Lower Saxony content from 23,61% to 25,43% (+2 % ) (population: 50,000) ≙ 7% Pilot test of FlocFormer 3L Infraserv GmbH & Co. KG, Chamber filter press Industry digested Better dewatering Dewatering result increase Industrial Park Höchst, Frankfurt am sludge performance of from 27,4% TS to 32,4% TS Main, Hesse Industry primary chamber filter press (+5%) ≙ 18% (population: 687,500) and secondary High annual savings slugde in relation Pilot test of FlocFormer 5L 1:1 Abwasserbetrieb Warendorf, Northrhine- Decanter Digested sludge Increase of dry mass Increase of decanter‘s hinge Westphalia content moment (population: 37,000) Increase of dry mass content from 21,4% to 26,3 (+5%) Pilot test of FlocFormer 5L ≙ 22% Clean centrifuge effluent Herforder ABWasser GmbH Decanter Digested sludge Increase of dry mass Increase of dry mass content Herford, Northrhine-Westphalia content from 30% to 35,7% (+5%) ≙ (population: 250,000) 19% Pilot test of FlocFormer 5L aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 5 List of references aquen aqua-engineering GmbH Sewage works Rüsselsheim, Hesse membrane filter press Digested sludge Increase of dry mass Increase of dewatering (population: 60,200) content performance from 23,3% to Retrenchment of 26,4% (+ 3%) ≙ 13% Pilot test of FlocFormer 3L polymer Increase of filling volume of chamber filter press about + 24 % Energieversorgung Sylt GmbH, Decanter Digested sludge Increase of dry mass Increase of dry mass content Sylt/Westerland content from 21,5% to 22,5% (+ 1%) ≙ (population: 100,000) Retrenchment of 5% polymer Retrenchment of polymer to 6 Pilot test FlocFormer 5L kg / t Better quality of centrifuge effluent Stadtentwässerungsbetriebe Cologne Chamber filter press Digested sludge Increase of dry mass Increase of filling volume of AöR, Northrhine-Westphalia content chamber filter press Sewage works Weiden Increase of dewatering (population 88,000) performance from 23,3% to 28 % (+4,7%) ≙ 20% Pilot test of FlocFormer 3L Stadtentwässerungsbetriebe Cologne Decanter Digested sludge Increase of dry mass Increase of dry mass content AöR, Northrhine-Westphalia content from 30 % to 32% (+2%) Sewage works Rodenkirchen ≙ 6% (population 88,000) Pilot test FlocFormer 3L aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 6 List of references aquen aqua-engineering GmbH Wasser- und Bodenverband Wahn, Chamber filter press Digested sludge Increase of dry mass Increase of filling volume of Cologne, Northrhine-Westphalia content chamber filter press (population: 92,000) Gaining influence of flocculation Pilot test FlocFormer 3L Schill & Seilacher GmbH, Böblingen, Chamber filter press Industry sludge Better dewatering Better attitude of Baden-Württemberg performance of sedimentation (population: 45,000) chamber filter press Pilot test FlocFormer 3L Switzerland Biorender AG, Münchwilen, Thurgau Decanter Digestate Increase of dry mass Better quality of centrifuge (population: 4,900) content effluent Increase of decanter‘s hinge Pilot test FlocFormer 3L moment aquen aqua-engineering GmbH | Bauhofstraße 31 | 38678 Clausthal-Zellerfeld | [email protected] | www.aquen.de 7 .