P802.3Ah Draft 2.0 Comments

Total Page:16

File Type:pdf, Size:1020Kb

P802.3Ah Draft 2.0 Comments P802.3ah Draft 2.0 Comments Cl 00 SC P L # 952 Cl 00 SC P L # 1248 Thompson, Geoff Nortel Lee Sendelbach IBM Comment Type TR Comment Status R Comment Type E Comment Status A What is being proposed in many places throughout this draft is not a peer network. To Fix all the references with *ref*. Like 60.9.4, 60.8.13.2.1, 60.8.13.1 60.8.11 60.1 I don't introduce such a foreign concept into a document where the implicit and explicit notion of understand what is going on with the *refs. Also fix #CrossRef# in 64.1 peer relationships is so thoroughly infused throughout the existing document is likely to SuggestedRemedy cause (a) significant confusion and (b) significant errors. Fix it. SuggestedRemedy Move non-peer proposals to a new and separate document that can thoroughly, explicitly Proposed Response Response Status C and unambigiously embrace the concept of Ethernet Services over asymetrical ACCEPT IN PRINCIPLE. infrastructure. These references are intended for the use of the editors to search for cross references. All Proposed Response Response Status U these will be romeved at time of publication as indicated in the editor's note boxes REJECT. Cl 00 SC P L # 951 The suggested remedy is ambiguous. What are "the non-peer proposals"? What is the Thompson, Geoff Nortel "new and separate document"? Comment Type TR Comment Status A reassigned The draft in its current form satisfies the PAR and 5 Criteria for the project, which call for an I have a problem with the use of the term "loopback" for the diagnostic return path being amendment to IEEE Std 802.3, formatted as a set of clauses. The suggested remedy proposed for the OAM sublayer. The potential for confusion of this new path with the would not satisfy the PAR and 5 Criteria. existing half-duplex DO to DI loopback path and its associated term of "loopback" is great. The term "loopback" has been an accepted label for this function at least since the drafting While there are asymetric physical layer specifications in the draft, the services provided to of FOIRL (ref: 9.9.2.1) in 1987. the MAC Client are provided in the same fashion as the base standard. The peer relationship between MAC Clients described in the base standard is preserved. SuggestedRemedy Pick another terminology. Previous projects introduced physical layers with asymetric behavior and characteristics. Proposed Response Response Status U For further information regarding document restructuring, see the file: ACCEPT. http://www.ieee802.org/3/efm/public/sep03/frazier_1_0903.pdf The term "loopback", as used within Clause 57, is used in reference to a remote loopback of frames. Occasionally, the word "loopback" is improperly used without being preceded by Cl 00 SC P L # 579 the word "remote". See for example Figure 57-3 at line 20 on page 138. This figure title Glen Kramer Teknovus should be changed to read "OAM remote loopback". If the term "OAM remote loopback" is used consistently, this should provide an adequate differentiation from the loopback Comment Type E Comment Status A olt defined in earlier clauses. In many places the abbreviation OLT is incorrectly expanded as Optical Line Termination. The correct term should be Terminal. Note that this problem was actually introduced in 802.3ae, SuggestedRemedy see for example Figure 45-2. Change "termination" to "terminal". The fix should be applied to C1.5 (page 13, line 12), Fig. 56-2 (page 169), C56.1.2.1 (page 169, line 52), Fig. 60-1 (page 289), and Fig. 66-4 (page 520). Proposed Response Response Status C ACCEPT. Refer 197 TYPE: TR/technical required T/technical E/editorial COMMENT STATUS: D/dispatched A/accepted R/rejected SORT ORDER: Clause, Page, Line, Subclause Page 1 of 269 RESPONSE STATUS: O/open W/written C/closed U/unsatisfied Z/withdrawn Cl 00 SC P802.3ah Draft 2.0 Comments Cl 00 SC P L # 829 Cl 00 SC P L # 837 Tzannes, Marcos Aware Brand, Richard Nortel Networks Comment Type T Comment Status A reassigned Comment Type TR Comment Status R In T1.424 9.3.5.5 it is not clearly specified how many EOC bytes per frame are mandatory Fundamental structural issue. even though the maximum number of EOC byte per frame is exchaged during startup in O- With the addition of a minimum of at least 562 pages of D 2.0 of EFM to the existing 802.3 MSG2 and R-MSG2. document, the IEEE 802.3 document will become overly large. At this point, I find it extremely time consuming to scan the existing 802.3 document for consistency with the SuggestedRemedy new draft sections. With so much bulk, we run an increased risk of approving a document State that support of 1 EOC byte per frame is mandatory. Also remove max EOC byte per that may not be up to our past level of quality. frame field from the initialization messages O-MSG2, R-MSG2 and O-CONTRACT. The material that is generated by future Task Forces will only exacerbate this situation. Proposed Response Response Status C SuggestedRemedy ACCEPT IN PRINCIPLE. Move EFM into a new separate 802.3 document that addresses an Ethernet for service providers and/or access networks. The existing text is sufficient. Refer to 828. Proposed Response Response Status U Cl 00 SC P L # 1181 REJECT. Parsons, Glenn Nortel Networks The draft in its current form satisfies the PAR and 5 Criteria for the project, which call for an Comment Type TR Comment Status A all amendment to IEEE Std 802.3, formatted as a set of clauses. The suggested remedy PICS mapping to clauses is incomplete as not all PICS entries are supported by would not satisfy the PAR and 5 Criteria. 'mandatory', 'shall', 'optional' or 'may' text within the clauses. The page count for this draft is not extraordinary in comparison to other recent projects in SuggestedRemedy 802.3. As an example, IEEE Draft P802.3ae/D5.0 had a page count of 540 pages when it Review all PICS entries to ensure that each entry references an appropriate 'mandatory', was approved by the sponsor ballot group and the IEEE-SA Standards Board. 'shall', 'optional' or 'may' text within the referenced clause. It is expected that the IEEE publications staff will elect to publish EFM as the fifth volume Review all clauses to ensure that all instances of 'mandatory', 'shall', 'optional' or 'may' of a future edition of IEEE Std 802.3, which will make it easy for the document reader to within the clause have a corresponding PICS entry. select the relevant specification. Proposed Response Response Status C For further information regarding document restructuring, see the file: ACCEPT IN PRINCIPLE. http://www.ieee802.org/3/efm/public/sep03/frazier_1_0903.pdf The convention used in 802.3 is that each "shall" statement correspondes to a PICS entry. Other words, such as "mandatory", "optional", and "may", do not receive corresponding PICS entries. Every effort has been made to follow this convention, and any specific instances that the commenter can identify that do not follow this convention will be corrected. If appropriate to document this convention then a maintenance request will be made by the commentor. TYPE: TR/technical required T/technical E/editorial COMMENT STATUS: D/dispatched A/accepted R/rejected SORT ORDER: Clause, Page, Line, Subclause Page 2 of 269 RESPONSE STATUS: O/open W/written C/closed U/unsatisfied Z/withdrawn Cl 00 SC P802.3ah Draft 2.0 Comments Cl 00 SC P L # 1167 Cl 00 SC P L # 1160 Parsons, Glenn Nortel Networks Parsons, Glenn Nortel Networks Comment Type TR Comment Status R Comment Type TR Comment Status A reassigned Amalgamation of these numerous seemingly unrelated clauses into the 802.3 standard is Clause 21 does not sufficiently define the PICS as used in this specification. For example, unrealistic. That is, using 'Ethernet' to bind all these clauses together stretches the the '*ITEM' notation to indicate an item is used as a predicate is not defined. It is defined in meaning of Ethernet beyond what was originally intended and also restricts how much can 802.1Q-1998 Clause A.3.4.2 be changed to add new functionality. SuggestedRemedy SuggestedRemedy Add reference to 802.1Q in Clause 21 or change references in each of the PICS clauses Rework this draft to be a stand-alone standard for 'access' or 'carrier' Ethernet. This would primarily affect the ammendments to clauses of 802.3. This draft would then, for example, Proposed Response Response Status C have its own clause 4 with 'obsolete' material removed and new functions added. The ACCEPT IN PRINCIPLE. existing 802.3 standard could then be termed as 'legacy' or 'enterprise' Ethernet. The commenter is asked to submit a comment in the next maintenance request on Cl. 21 Proposed Response Response Status U REJECT. Cl 00 SC P L 1 # 596 Grow, Robert Intel The draft in its current form satisfies the PAR and 5 Criteria for the project, which call for an amendment to IEEE Std 802.3, formatted as a set of clauses. The suggested remedy Comment Type TR Comment Status A would not satisfy the PAR and 5 Criteria. Per recent changes, we should begin including the front matter in the draft by Sponsor Ballot. Numerous prior projects performed amendments to the base standard. The scope of the changes described in the draft is consistent with past practice. With regard to the specific SuggestedRemedy example given in the suggested remedy, the combination of physical layers described in This is classified as a TR to assure it is implemented prior to Sponsor Ballot.
Recommended publications
  • VSC8489-10 and VSC8489-13
    VSC8489-10 and VSC8489-13 Dual Channel WAN/LAN/Backplane Highlights RXAUI/XAUI to SFP+/KR 10 GbE SerDes PHY • IEEE 1588v2 compliant with VeriTime™ • Failover switching and lane ordering Vitesse’s dual channel SerDes PHY provides fully • Simultaneous LAN and WAN support IEEE 1588v2-compliant devices and hardware-based KR • RXAUI/XAUI support support for timing-critical applications, including all • SFP+ I/O with KR support industry-standard protocol encapsulations. • 1 GbE support VeriTime™ is Vitesse’s patent-pending distributed timing technology Applications that delivers the industry’s most accurate IEEE 1588v2 timing implementation. IEEE 1588v2 timing integrated in the PHY is the • Multiple-port RXAUI/XAUI to quickest, lowest cost method of implementing the timing accuracy that SFI/ SFP+ line cards or NICs is critical to maintaining existing timing-critical capabilities during the • 10GBASE-KR compliant backplane migration from TDM to packet-based architectures. transceivers The VSC8489-10 and VSC8489-13 devices support 1-step and 2-step • Carrier Ethernet networks requiring PTP frames for ordinary clock, boundary clock, and transparent clock IEEE 1588v2 timing applications, along with complete Y.1731 OAM performance monitoring capabilities. • Secure data center to data center interconnects The devices meet the SFP+ SR/LR/ER/220MMF host requirements in accordance with the SFF-8431 specifications. They also compensate • 10 GbE switch cards and router cards for optical impairments in SFP+ applications, along with degradations of the PCB. The devices provide full KR support, including KR state machine, for autonegotiation and link optimization. The transmit path incorporates a multitap output driver to provide flexibility to meet the demanding 10GBASE-KR (IEEE 802.3ap) Tx output launch requirements.
    [Show full text]
  • IEEE 802.3 Working Group November 2006 Plenary Week
    IEEE 802.3 Working Group November 2006 Plenary Week Robert M. Grow Chair, IEEE 802.3 Working Group [email protected] Web site: www.ieee802.org/3 13 November 2006 IEEE 802 November Plenary 1 Current IEEE 802.3 activities • P802.3ap, Backplane Ethernet Published• P802.3aq, 10GBASE-LRM • P802.3ar, Congestion Management Approved• P802.3as, Frame Format Extensions • P802.3at, DTE Power Enhancements • P802.3av, 10 Gb/s EPON New • Higher Speed Study Group 13 November 2006 IEEE 802 November Plenary 2 P802.3ap Backplane Ethernet • Define Ethernet operation over electrical backplanes – 1Gb/s serial – 10Gb/s serial – 10Gb/s XAUI-based 4-lane – Autonegotiation • In Sponsor ballot • Meeting plan – Complete resolution of comments on P802.3ap/D3.1, 1st recirculation Sponsor ballot – Possibly request conditional approval for submittal to RevCom 13 November 2006 IEEE 802 November Plenary 3 P802.3aq 10GBASE-LRM • Extends Ethernet capabilities at 10 Gb/s – New physical layer to run under 802.3ae specified XGMII – Extends Ethernet capabilities at 10 Gb/s – Operation over FDDI-grade multi-mode fiber • Approved by Standards Board at September meeting • Published 16 October 2006 • No meeting – Final report to 802.3 13 November 2006 IEEE 802 November Plenary 4 P802.3ar Congestion Management • Proposed modified project documents failed to gain consensus support in July • Motion to withdraw the project was postponed to this meeting • Current draft advancement to WG ballot was not considered in July • Meeting plan – Determine future of the project – Reevaluate
    [Show full text]
  • CODING for Transmission
    CODING for Transmission Professor Izzat Darwazeh Head of Communicaons and Informaon System Group University College London [email protected] Acknowledgement: Dr A. Chorti, Princeton University for slides on FEC coding Dr P.Moreira, CERN, for slides on the CERN Gigabit Transmitter (GBT) Dr J. Mitchell, UCL, for the sampled music and voice. June 2011 Coding • Defini7ons and basic concepts • Source coding • Line coding • Error control coding Digital Line System Message Message source Distortion, sink interference Input Output signal and noise signal Encoder- Demodulator modulator -decoder Communication Transmitted channel Received signal signal Claude Shannon • Shannon’s Theorem predicts reliable communicaon in the presence of noise “Given a discrete, memoryless channel with capacity C, and a source with a posi8ve rate R (R<C), there exist a code such that the output of the source can be transmi@ed over the channel with an arbitrarily small probability of error.” • B is the channel bandwidth in Hz and S/N is the signal power to noise power rao ⎛⎞S CBc =+log2 ⎜⎟ 1 ⎝⎠N Types of Coding • Source Coding – Encoding the raw data • Line (or channel) Coding – Formang of the data stream to benefit transmission • Error Detec7on Coding – Detec7on of errors in the data seQuence • Error Correcon Coding – Detec7on and Correc7on of Errors • Spread Spectrum Coding – Used for wireless communicaons Signals and sources: Discrete - Con8nuous m(t) n Continuous Time and Amplitude n Discrete Time, continuous Amplitude – PAM signal n Discrete Time, and Amplitude
    [Show full text]
  • Customer Issues and the Installed Base of Cabling
    CustomerCustomer andand MarketMarket Issues:Issues: 1010 GbpsGbps EthernetEthernet onon CategoryCategory 55 oror BetterBetter CablingCabling Bruce Tolley Cisco Systems, Inc [email protected] 1 IEEE 802.3 Interim January 2003 GbEGbE SwitchSwitch Ports:Ports: FiberFiber vsvs CopperCopper Ports (000s) 802.3ab 8,000 STD 7,000 6/99 6,000 802.3z 5,000 STD Total 4,000 6/98 Fiber 3,000 Copper 2,000 1,000 0 1997 1998 1999 2000 2001 2002 2 Source: Dell’Oro 2002 IEEE 802.3 Interim January 2003 SuccessSuccess ofof GbEGbE onon CopperCopper • It is 10/100/1000 Mbps • It runs Cat5, 5e and 6 • It does not obsolete the installed base • It does not require both ends of the link to be upgraded at the same time 3 IEEE 802.3 Interim January 2003 1010 GbEGbE LayerLayer DiagramDiagram Media Access Control (MAC) Full Duplex 10 Gigabit Media Independent Interface (XGMII) or 10 Gigabit Attachment Unit Interface (XAUI) CWDM Serial Serial LAN PHY LAN PHY WAN PHY (8B/10B) (64B/66B) (64B/66B + WIS) CWDM Serial Serial Serial Serial Serial Serial PMD PMD PMD PMD PMD PMD PMD 1310 nm 850 nm 1310 nm 1550 nm 850 nm 1310 nm 1550 nm -LX4 -SR -LR -ER -SW -LW -EW Source: Cisco Systems 4 IEEE 802.3 Interim January 2003 Pluggable 10 GbE Modules: The Surfeit of SKUs 10GBASE XENPAK X2/XPAK XFP PMDs XAUI XAUI -SR X X -LR X X X -ER X X -LX4 X X -CX4 X X -T X X X CWDM, X X X DWDM Please: No new pluggable for 10GBASE-T! 5 IEEE 802.3 Interim January 2003 CumulativeCumulative WorldWorld--widewide ShipmentsShipments 1300 1200 Cat 7 Cat5 Cat5 1100 Cat 6 59% 51% 1000 Cat 5e 900 Cat 5 800
    [Show full text]
  • SGI® IRIS® Release 2 Dual-Port Gigabit Ethernet Board User's Guide
    SGI® IRIS® Release 2 Dual-Port Gigabit Ethernet Board User’s Guide 007-4324-001 CONTRIBUTORS Written by Matt Hoy and updated by Terry Schultz Illustrated by Dan Young and Chrystie Danzer Production by Karen Jacobson Engineering contributions by Jim Hunter and Steve Modica COPYRIGHT © 2002, 2003, Silicon Graphics, Inc. All rights reserved; provided portions may be copyright in third parties, as indicated elsewhere herein. No permission is granted to copy, distribute, or create derivative works from the contents of this electronic documentation in any manner, in whole or in part, without the prior written permission of Silicon Graphics, Inc. LIMITED RIGHTS LEGEND The electronic (software) version of this document was developed at private expense; if acquired under an agreement with the US government or any contractor thereto, it is acquired as “commercial computer software” subject to the provisions of its applicable license agreement, as specified in (a) 48 CFR 12.212 of the FAR; or, if acquired for Department of Defense units, (b) 48 CFR 227-7202 of the DoD FAR Supplement; or sections succeeding thereto. Contractor/manufacturer is Silicon Graphics, Inc., 1600 Amphitheatre Pkwy 2E, Mountain View, CA 94043-1351. TRADEMARKS AND ATTRIBUTIONS Silicon Graphics, SGI, the SGI logo, IRIS, IRIX, Octane, Onyx, Onyx2, and Origin are registered trademarks, and Octane2, Silicon Graphics Fuel, and Silicon Graphics Tezro are trademarks of Silicon Graphics, Inc., in the United States and/or other countries worldwide. FCC WARNING This equipment has been tested and found compliant with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
    [Show full text]
  • Gigabit Ethernet Pocket Guide
    GbE.PocketG.fm Page 1 Friday, March 3, 2006 9:43 AM Carrier Class Ethernet, Metro Ethernet tester, Metro Ethernet testing, Metro Ethernet installation, Metro Ethernet maintenance, Metro Ethernet commissioning, Carrier Class Ethernet tester, Carrier Class Ethernet testing, Carrier Class Ethernet installation, Carrier Class Ethernet maintenance, Gigabit Ethernet tester, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet protocols, 1000BASE-T tester, 1000BASE-LX test, 1000BASE-SX test, 1000BASE-T testing, 1000BASE-LX testing Trend’s Gigabit EthernetPocket Guide AuroraTango Gigabit Ethernet Multi-technology Personal Test Assistant Platform for simple, fast and effective testing of Gigabit Ethernet, ADSL, OSI model 802.3 model SHDSL, and ISDN. Aurora Tango 7 Application Upper layers Gigabit Ethernet has an exceptional 6 Presentation Reconciliation range of features Upper ensuring reliable delivery of end-to-end 5 Session layers services over Metropolitan networks MII Media independent based on Gigabit Ethernet. 4 It includes a full range of tests and Transport measurements, such as RFC-2544, PCS top ten addresses, real-time Ethernet 3 Network LLC (802.2) statistics, multilayer BERT, etc. Two PMA Gigaport transceivers allow terminate, 2 Data Link MAC (803.3) loopback and monitor connections to Autonegotiation networks, plus a 10/100/1000BASE-T Physical cable port for legacy testing. 1 PHY (802.3) dependent Media MDI A PDA provides an intuitive graphical menu
    [Show full text]
  • ETRI PHY Proposal on VLC Line Code for Illumination
    September 2009 doc.: IEEE 802.15-09-0675-00-0007 Project: IEEE P802.15 Working Group for Wireless Personal Area Networks (WPANs) Submission Title: [ETRI PHY Proposal on VLC Line Code for Illumination] Date Submitted: [23 September, 2009] Source: [Dae Ho Kim, Tae-Gyu Kang, Sang-Kyu Lim, Ill Soon Jang, Dong Won Han] Company [ETRI] Address [138 Gajeongno, Yuseong-gu, Daejeon, 305-700] Voice:[+82-42-860-5648], FAX: [+82-42-860-5218], E-Mail:[[email protected]] Re: [Response to call for proposals] Abstract: [This document describes a proposal of PHY line code for LED illumination ] Purpose: [Proposal to IEEE 802.15.7 VLC TG]] Notice: This document has been prepared to assist the IEEE P802.15. It is offered as a basis for discussion and is not binding on the contributing individual(s) or organization(s). The material in this document is subject to change in form and content after further study. The contributor(s) reserve(s) the right to add, amend or withdraw material contained herein. Release: The contributor acknowledges and accepts that this contribution becomes the property of IEEE and may be made publicly available by P802.15. TG VLC Submission Slide 1 Dae-Ho Kim, ETRI September 2009 doc.: IEEE 802.15-09-0675-00-0007 ETRI PHY Proposal on VLC Line code for Illumination Dae Ho Kim [email protected] ETRI TG VLC Submission Slide 2 Dae-Ho Kim, ETRI September 2009 doc.: IEEE 802.15-09-0675-00-0007 Contents • ETRI PHY Considerations and Scope • Summary of ETRI PHY Proposal • Flickering issue at LED illumination • Proposed Line Code – Modified-4B5B
    [Show full text]
  • Modulation  Copper Access Technologies  Wireless Subscriber Line  Cable Television
    Dr. Beinschróth József Telecommunication informatics I. Part 2 ÓE-KVK Budapest, 2019. Dr. Beinschróth József: : Telecommunication informatics I. Content Network architectures: collection of recommendations The Physical Layer: transporting bits The Data Link Layer: Logical Link Control and Media Access Control Examles for technologies based on the Data Link Layer The Network Layer 1: functions and protocols The Network Layer 2: routing Examle for technology based on the Network Layer The Transport Layer The Application Layer Criptography IPSec, VPN and border protection QoS and multimedia Additional chapters Dr. Beinschróth József: : Telecommunication informatics I. 2 Content of this chapter (1) Network models Theory Media for Data Transmission Twisted Pair Coaxial cable and optical fiber Wireless Data transmission Network topology PSTN Data Transmission Main Parameters of the Physical Layer Mechanical and electrical parameters Functional parameters Approaching from the physical layer Baseband transmission Bitflow (stream) transmission with modulation Copper access technologies Wireless subscriber line Cable Television Dr. Beinschróth József: : Telecommunication informatics I. 3 The physical layer: The lowest layer of the OSI model OSI TCP/IP Hybrid Application Layer Presentation Layer Application Layer Application Layer Session Layer Transport Layer Transport Layer Transport Layer Network Layer Network Layer Network Layer Data Link Layer Data Link Layer Physical Layer Physical Layer Physical Layer Network
    [Show full text]
  • Cisco Presentation Guide
    EthernetEthernet PetrPetr GrygGrygáárekrek © 2005 Petr Grygarek, Advanced Computer Networks Technologies 1 EthernetEthernet HistorHistoryy •ResearchResearch background:background: AlohaNetAlohaNet •UniversityUniversity ofof Hawai,Hawai, 19701970:: commoncommon (radio)(radio) channelchannel sharingsharing methodsmethods –– basisbasis forfor CSMA/CDCSMA/CD •1980:1980: DIXDIX publishedpublished EthernetEthernet standardstandard (Metcalfe)(Metcalfe) •1985:1985: IEEEIEEE 802802.3.3 (MAC(MAC andand LLCLLC layers)layers) •10Base5,10Base5, 10Base2,10Base2, 10BaseT10BaseT •19951995 IEEEIEEE 802.3u802.3u (Fast(Fast Ethernet)Ethernet) •19981998 IEEEIEEE 802.3z802.3z (Gigabit(Gigabit Ethernet)Ethernet) •20022002 IEEEIEEE 802.3ae802.3ae (10Gb(10Gb Ethernet)Ethernet) •...... © 2005 Petr Grygarek, Advanced Computer Networks Technologies 2 EthernetEthernet NamingNaming RulesRules (IEEE(IEEE Standard)Standard) MbpsMbps [Base|Broad][Base|Broad] [segment[segment_length_length_m_m || -medium-medium]] --TT -- TwistedTwisted Pair,Pair, --FF -- FiberFiber optic,optic, ...... e.g.e.g. 10Base5,10Base5, 10BaseT,10BaseT, 100BaseF100BaseF NameName ofof eacheach particularparticular EthernetEthernet technologytechnology defineddefined inin individualindividual supplementsupplementss ofof 802.3802.3 standardstandard •e.ge.g 802.3u,802.3u, 802.3ab,802.3ab, 802.3z802.3z © 2005 Petr Grygarek, Advanced Computer Networks Technologies 3 Half-duplexHalf-duplex andand Full-duplexFull-duplex EthernetEthernet •HalfHalf duplexduplex –– colissioncolission envirnmentenvirnment
    [Show full text]
  • AH1721 SJA1105SMBEVM User Manual Rev
    AH1721 SJA1105SMBEVM User Manual Rev. 1.00 — 16 July 2018 User Manual Document information Info Content Keywords SJA1105PQRS, SJA1105S, SJA1105S Evaluation Board, SJA1105SMBEVM, Cascading, Ethernet, Wakeup, Sleep Abstract The SJA1105SMBEVM Evaluation Board is described in this document. NXP Semiconductors AH1721 SJA1105SMBEVM UM Revision history Rev Date Description 1.00 20180716 Release Contact information For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: mailto:[email protected] AH1721 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2018. All rights reserved. User Manual Rev. 1.00 — 16 July 2018 2 of 35 NXP Semiconductors AH1721 SJA1105SMBEVM UM 1. Introduction The SJA1105SMBEVM (SJA1105S Mother Board Evaluation Module, see Fig 1) is designed for evaluating the capabilities of the SJA1105P/Q/R/S Automotive Ethernet switch family and the TJA1102 Automotive Ethernet PHYs, by developing and running customer software. Therefore, the board features the MPC5748G MCU with a rich set of peripherals for communication and automotive applications. It is designed to allow early adaptions of applications, like a X-to-Ethernet gateway, communication hub, etc. Fig 1. SJA1105SMBEVM board This user manual describes the board hardware and the software development environment to allow the user to quickly bring up a working system and to pave the way towards an own customized software, and in the end towards an all custom system. After the HW description the manual walks the user through the process to create the factory firmware starting at the supplied example project and describes the recommended SW development environment S32 Design Studio for Power as far as it is needed for the example project.
    [Show full text]
  • IEEE802.3Z Gigabit Ethernet UTP5 Proposal V2.0 November, 1996
    IEEE802.3z Gigabit Ethernet UTP5 Proposal V2.0 Project: IEEE 802.3z Gigabit Ethernet Task Force Source: Steve Dabecki ([email protected]) Barry Hagglund ([email protected]) Richard Cam ([email protected]) Vern Little ([email protected]) Iain Verigin ([email protected]) PMC-Sierra Inc 105-8555 Baxter Place Burnaby BC Canada V5A 4V7 Tel: 604.415.6000 Web: http://www.pmc-sierra.com Title: Physical Layer Proposal for 1 Gbit/s Full / Half Duplex Ethernet Transmission over Single (4-pair) or Dual (8-pair) UTP-5 Cable. Issue: 2.0 Date: November 11-14, 1996 Abstract The extension of the current IEEE802.3 specifications to support a bit rate of 1Gbps is currently under investigation by the HSSG. These bit rates are regarded to be essential to support the high bandwidth requirements of mixed 10BASE and 100BASE networks, and many applications requiring a dedicated high speed link to a server. The HSSG has already made excellent progress in the way of defining 1000BASE for fibre. This contribution outlines an approach for supporting 1Gbps, either half or full- duplex, over single (4-pair) or dual (8-pair) unshielded twisted pair category 5 (UTP-5) cable. Notice This contribution has been prepared to assist the IEEE802.3z HSSG. This document is offered to the IEEE802.3z HSSG as a basis for discussion and is not a binding proposal on PMC-Sierra, Inc. or any other company. The statements are subject to change in form and/or content after further study. Specifically, PMC-Sierra, Inc.
    [Show full text]
  • 8-Port Gigabit Switch
    GSW-0809 Version: 3 8-Port Gigabit Switch The LevelOne GSW-0809 Gigabit Ethernet Switch is designed for reliable high-performance networking. With its non-blocking switching fabric in full-duplex mode, this switch can deliver up to 2000Mbps per port, while the Store-and-Forward service brings low latency and error-free packet delivery. This highperformance Gigabit Ethernet switch is perfect for fulfilling the demands of online gaming and multimedia streaming. Moreover, this switch also supports IEEE 802.3az Energy Efficient Ethernet which helps reduce power consumption. Power Saving Features The GSW-0809supports IEEE 802.3az Energy Efficient Ethernet to provide power-saving benefits without compromising performance. One of the ways it does this is by automatically detecting the length of connected cables and can adjust power usage by saving energy on shorter cable connections. Internal Power With a built-in power supply, GSW-0809 is simple to install and use. No bulky adapters will hang on the wall and get in the way of your other electronic devices. Keep your desktop and computer area free from the clutter of cords! Easy to Use The GSW-0809 features plug-and-play for easy installation. No configuration is required. Autonegotiation on each port senses the link speed of a network device and adjusts for compatibility and optimal performance. Key Features - 8 Gigabit Ethernet ports - 10/100/1000Mbps wire speed transmission and reception - 9K jumbo frames to increase data transfer rates - Supports 8K MAC address auto-learning and auto-aging
    [Show full text]