AND D ING RAIN ® MB AG U E L SMITH P LOCATION JAY R. B ERR ® MME M B E V ITAR I AN Y MFG. CO. NSTITUTE ® S MEMBERSMITH OF MORRIS GROUP INTERNATIONAL POST OFFICE BOX 3237

MONTGOMERY, ALABAMA 36109-0237 (USA) E ASPE P N G r G N e TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com ev I I r ® en N E E R u MEMBER OF: ti C CUSTOMER on han DRIVEN Rather T SINCE 1926 LARGE GENERAL PURPOSE DRAINS S1010 LOW PROFILE FUNCTION: Used in flat roof of any construction. Large low profile dome provides sufficient free area for quick of rain and protects the drain sump and connected from the intrusion of debris. Wide clamping surface holds flashing and roofing materials without puncturing. 15 1/4 (390) DIA DRAWING NUMBER DRAWING

Polyethylene Dome D DIA Dome 5 1/4 A

SIZE Combined Flashing (135) Clamp And Gravel Stop 5 1/4 1 1/8 (29) MIN (135) Combined Flashing Clamp And Gravel B Stop C A F MIN Underdeck Clamp NONE C* (When Specified) SCALE: B H Underdeck Clamp G J A (When Specified) Fig. 1020C 02(50), 03(75) & 04(100)" CAULK OUTLET *This Dimension to Internal E DIA Fig. 1020T 02(50), 03(75) & 04(100)" THREADED OUTLET Stop of Speedi-Set Gasket. 5-24-85 **NOTE: 08(200) & 10(250) outlet Fig. 1010C . . . .CAULK OUTLET sizes are regularly furnished with 16 (405) DIA

DATE: 20(510) dia. , see back sheet. Fig. 1010Y . . . .NO-HUB OUTLET If 16(405) dia. flange is required -16 Polyethylene Dome

WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA ASSUME NO RESPONSIBILITY WE CAN MUST be specified. 5 1/4 recommended opening Ex: 1010Y08-16 or 1010Y10-16 Combined Flashing (135) outlet with less Clamp And Gravel Stop size suffix-R suffix-R TD 02(50),03(75),04(100) 1 1/8 (29) MIN 05(125),06(150) 17(430) DIA 14(355) DIA B **08(200)-16, **10(250)-16 17(430) DIA 14 3/4 (375) DIA C APPROVED BY: Underdeck Clamp A (When Specified) A B (BOTTOM OUTLET) SIDE OUTLET FREE AREA SIZE CAULK, NO-HUB, D E F SQ IN THREADED C G H J (SQ CM) & SPEEDI-SET DIA DIA MIN H 02(50),03(75), 5 3 3/4 3 3/4 15 1/4 11 1 1/8 4 3/4 6 7 3/4 102.5 G J TD 04(100) (125) (95) (95) (390) (280) (29) (120) (150) (195) (661) 05(125), 5 3 3/4 -- 15 1/4 11 1 1/8 6 1/4 6 7/8 7 3/4 102.5 Fig. 1020C 05(125) & 06"(150) 06(150) (125) (95) (390) (280) (29) (160) (175) (195) (661) CAULK OUTLET **08(200)-16, 6 5 -- 16 12 1/2 1 1/8 ------102.5(661)

CHECKED BY: Fig. 1020T 05(125) & 06"(150) **10(250)-16 (150) (125) (405) (320) (29) 122.5(790) THREADED OUTLET (SIDE OUTLET) 02 (50) 03 (75) 04 (100) 05 (125) 06 (150) REGULARLY FURNISHED: VARIATIONS: A SIZE B 6 7/8 6 3/8 5 7/8 5 4 1/2 CR Duco Body with Combined Expansion Joint (Specify Fig. 1710) (Fig. 1010 only) (175) (162) (149) (125) (115) Flashing Clamp and Gravel Stop with Extension (Specify Height) -E C 8 5/8 8 3/4 8 3/4 8 1/2 8 1/2 Polyethylene Dome. "L" Shaped Underdeck Clamp -CL (219) (220) (220) (215) (215)

DRAWN BY: DRAWN L Speedi-Set Service Weight OPTIONAL MATERIALS: 02(50), 03(75) and 04(100)" sizes only All Aluminum -AA (Fig. 1010 only) (Fig. 1010 0nly) ▲▲ Aluminum Dome -AD NOTE: The dome height is 8 1/4" (210) LXH Speedi-Set Extra Heavy ▲▲ Cast Iron Dome -CID for the 122.5 SQ IN free area dome and 02(50), 03(75) and 04(100)" sizes only ▲▲ Galvanized Cast Iron Dome -CIDG is regularly furnished in Cast Iron and is (Fig. 1010 only) Galvanized Cast Iron Body & Collar -G not available in polyethylene. NO-HUB Adaptor (Specify Fig. 2646Y) ▲▲ Rough Dome -RBD (Fig. 1020 only) Stainless (Specify Fig. 9780) Secondary Flashing Clamp -C2 Sump Receiver -R ▲▲ Optional ’ free area are as follows: Underdeck Clamp -C Dome Mat’l 02-06 & 08-16 Outlets Aluminum 98 (632) Vandal Proof Dome -U NOTE: Dimensions shown in Cast Iron 80 (516) parentheses are in millimeters. T Threaded Outlet Bronze 95 (613) DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE AND CHANGE WITHOUT TOLERANCE MANUFACTURERS TO ARE SUBJECT DIMENSIONS 1010, 1020 V 7-30-19 Removed NOTE MW CL WEIGHT VOLUME FIGURE NUMBER U 8-3-15 Added Flow Rate Note TBW BW POUNDS CUBIC FEET T 3-12-13 Rev. Tables, Notes TBW CL S 06/01/09 Added Optional Dome free areas JJ CL REV. DATE DESCRIPTION BY CKD. BY FIGURE NUMBER 1010, 1020

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov AND D ING RAIN ® MB AG U E L SMITH P LOCATION JAY R. B ERR ® MME M B E

B ITAR I AN Y MFG. CO. NSTITUTE ® S MEMBERSMITH OF MORRIS GROUP INTERNATIONAL POST OFFICE BOX 3237

MONTGOMERY, ALABAMA 36109-0237 (USA) E ASPE P N G r G N e TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com ev I I r ® en N E E R u MEMBER OF: ti C CUSTOMER on han DRIVEN Rather T SINCE 1926 LARGE GENERAL PURPOSE ROOF DRAIN S1010BS FUNCTION: Used in flat roof construction. Large dome provides sufficient free area for quick drainage of rain water and protects the drain sump and connected piping from the intrusion of debris. Wide clamping surface holds flashing and roofing materials without puncturing. DRAWING NUMBER DRAWING

FREE AREA

A 228 SQ IN SIZE (1471 SQ CM)

20(510) DIA Cast Iron Dome NONE

SCALE: 7 1/4 Combined Flashing Clamp (185) and Gravel Stop

3-13-13 1 5/8(41) MIN

DATE: 7 3/4

WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA ASSUME NO RESPONSIBILITY WE CAN (195) Underdeck Clamp (when specified) CL

A recommended deck opening APPROVED BY: less suffix -R 18 3/4(475) DIA 16(405) DIA with suffix -R 21(535) DIA A ( SIZE) = 08(200), 10(250) or *12(305) *12(305) outlet size available in No-Hub only. CL

CHECKED BY: FIG.1010C...... CAULK OUTLET FIG.1010Y ...... NO-HUB OUTLET FIG.1010T ...... THREADED OUTLET TBW

REGULARLY FURNISHED: VARIATIONS: OPTIONAL MATERIALS: DRAWN BY: DRAWN Duco Cast Iron Body with Combined Extension (Specify Height) -E Aluminum Dome -AD Flashing Clamp and Gravel Stop and Secondary Flashing Clamp -C2 Galvanized Cast Iron -G Cast Iron Dome. Sump Receiver -R Galvanized Cast Iron Dome Underdeck Clamp -C Only -CIDG "L" Shaped Underdeck Clamp -CL Vandal Proof Dome -U Mesh Over Dome -SSM

NOTE: Dimensions shown in 1010BS parentheses are in millimeters. DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE AND CHANGE WITHOUT TOLERANCE MANUFACTURERS TO ARE SUBJECT DIMENSIONS WEIGHT VOLUME FIGURE NUMBER POUNDS CUBIC FEET B 7-30-19 Removed NOTE MW CL A 8-3-15 Added Flow Rate Note TBW BW REV. DATE DESCRIPTION BY CKD. BY FIGURE NUMBER 1010BS

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov