PLUMBING LEGEND and ABBREVIATIONS Heery International Inc

Total Page:16

File Type:pdf, Size:1020Kb

PLUMBING LEGEND and ABBREVIATIONS Heery International Inc PLUMBING LEGEND AND ABBREVIATIONS Heery International Inc. 4700 Millenia Blvd., Suite 550 Orlando, FL 32839 407.992.6300 ABBREVIATIONS - PLUMBING ABBREVIATIONS - PLUMBING SYMBOL LEGEND SYMBOL LEGEND PIPING LEGEND PIPING LEGEND NO NORMALLY OPEN Y STRAINER WITH BLOW OFF VALVE BOTTOM PIPE CONNECTION WASTE / VENT / STORM POTABLE WATER AD AREA DRAIN NPW NON-POTABLE WATER FLEXIBLE CONNECTION TOP PIPE CONNECTION Consultants AFF ABOVE FINISHED FLOOR OD OUTSIDE DIAMETER SAN SANITARY (ABOVE FLOOR) DOMESTIC COLD WATER PIPING (X) AP ACCESS PANEL OS&Y OUTSIDE SCREW & YOKE GATE VALVE (H) (L) EXPANSION LOOP SIZE VALVE IN VERTICAL SAN SANITARY (BELOW FLOOR) DOMESTIC HOT WATER PIPING CIVIL BLDG BUILDING OST OVERFLOW STORM SEISMIC JOINT P-TRAP MKA BOB BOTTOM OF BEAM P/FT PITCH PER FOOT AV ACID VENT PIPING DOMESTIC HOT WATER RETURN PIPING 1301 5TH AVE #3200 SHOCK ABSORBER FLOOR CLEANOUT/GRADE CLEANOUT SEATTLE, WA 98101 BOP BOTTOM OF PIPE POC POINT OF CONNECTION IW INDIRECT WASTE PIPING T 206-292-1200 BV BALANCING VALVE PRV PRESSURE REDUCING VALVE VACUUM BREAKER CLEANOUT/PLUG CD CONDENSATE DRAIN PIPING LANDSCAPE CD CONDENSATE DRAIN PSI POUNDS PER SQUARE INCH M MANUAL AIR VENT PIPE DOWN MISCELLANEOUS SITE WORKSHOP CFH CUBIC FEET PER HOUR PSIG POUNDS PER SQUARE INCH (GAUGE) GW GREASE WASTE PIPING 222 ETRURIA ST #200 P = SAN, VENT STACK OR DOMESTIC WATER RISER CFM CUBIC FEET PER MINUTE RISE RISE (WITH IN FLOOR) A AUTOMATIC AIR VENT PIPE UP SEATTLE, WA 98109 C CENTER LINE P ST = STORM DRAIN LEADER RISER T 206-285-3026 CFS CUBIC FEET PER SECOND SA SHOCK ABSORBER 1 RISER PRESSURE GAUGE AND COCK CAP NPW NON-POTABLE WATER F = FIRE STANDPIPE RISER RISER NO. CI CAST IRON SAN SANITARY STRUCTURAL THERMOMETER CHANGE IN PIPE ELEVATION CLG CEILING SD SMOKE DETECTOR ST STORM CP EQUIPMENT MKA EQUIPMENT DESIGNATION 1301 5TH AVE #3200 CO CLEANOUT SF SQUARE FEET WATER FLOW SWITCH ARROW INDICATES DIRECTION OF FLOW 1 EQUIPMENT NO. OST OVERFLOW STORM SEATTLE, WA 98101 COTG CLEANOUT TO GRADE SK SINK T 206-292-1200 RUNNING TRAP PITCH PIPE DOWN IN DIRECTION OF ARROW 1 DETAIL NUMBER CONN CONNECTION ST STORM PIPING DETAIL DESIGNATION MECHANICAL BASKET STRAINER FRESH AIR INLET P2.1 DWG. SHEET NO. CONT CONTINUATION TD TRENCH DRAIN WSP GROUP CP CIRCULATING PUMP TDH TOTAL DISCHARGE HEAD VALVE (SPECIFICATION FOR TYPE) WALL HYDRANT 1 SHEET NOTE NUMBER 600 UNIVERSITY ST, SUITE 500 SEATTLE, WA 98101 CV CHECK VALVE TMV TEMPERATURE MIXING VALVE T 206-342-9900 CHECK VALVE 1 REVISION NUMBER CW COLD WATER TOP TOP OF PIPE ELECTRICAL / TELCOM / AV DF DRINKING FOUNTAIN TOS TOP OF SLAB CHECK VALVE WITH ABD SPARLING DFU DRAINAGE FIXTURE UNIT TP TRAP PRIMER SOLENOID VALVE PLUMBING DRAWING LIST 4100 194TH ST SW #400 DIA DIAMETER TPV TRAP PRIMER VALVE LYNNWOOD, WA 98036 PRESSURE REDUCING VALVE DN DOWN TS TAMPER SWITCH SHEET NUMBER SHEET NAME T 206-667-0555 DR DRAIN TYP TYPICAL OS&Y (OUTSIDE SCREW & YOKE) VALVE LIGHTING P-000 PLUMBING LEGEND & ABBREVIATIONS DROP DROP (WITHIN FLOOR) CANDELA UON UNLESS OTHERWISE NOTED AUTOMATIC FLOW CONTROL VALVE PB101A PLUMBING UNDERGROUND PLAN DWG DRAWING 4100 194TH ST SW #400 UP UP (PENETRATES FLOOR SLAB) PB101B PLUMBING UNDERGROUND PLAN - SERVICE YARD LYNNWOOD, WA 98036 (E) EXISTING BUTTERFLY VALVE (MANUAL) PL100A PLUMBING FLOOR PLAN - BASEMENT LEVEL UR URINAL T 206-667-0511 PL100B PLUMBING FLOOR PLAN - BASEMENT LEVEL SERVICE YARD EEW EMERGENCY EYE WASH V VENT GLOBE VALVE PL101A PLUMBING FLOOR PLAN - LEVEL 1 EL ELEVATION SECURITY ELECTRONICS VB VACUUM BREAKER PL101B PLUMBING FLOOR PLAN - LEVEL 1 PARKING CALIBRATED BALANCING VALVE GUIDEPOST SOLUTIONS ET EXPANSION TANK VR VENT RISE PL102 PLUMBING FLOOR PLAN - LEVEL 2 388 17TH STREET SUITE 230 EWC ELECTRIC WATER COOLER VTR VENT THROUGH ROOF VALVE WITH TAMPER SWITCH PL103 PLUMBING FLOOR PLAN - LEVEL 3 OAKLAND, CA 94612 PL104 PLUMBING FLOOR PLAN - LEVEL 4 EWH ELECTRIC WATER HEATER WC WATER CLOSET T 510-268-8373 GAS COCK VALVE PL105 PLUMBING FLOOR PLAN - LEVEL 5 FCO FLOOR CLEANOUT WCO WALL CLEANOUT PL106 PLUMBING FLOOR PLAN - LEVEL 6 Revisions SEISMIC VALVE FD FLOOR DRAIN WH WALL HYDRANT PL107 PLUMBING FLOOR PLAN - LEVEL 7 FL FLOOR PL108 PLUMBING FLOOR PLAN - LEVEL 8 WF WATER FILTER RELIEF VALVE PL109 PLUMBING ROOF LEVEL FSK FLOOR SINK WFU WATER FIXTURE UNIT PL110 PLUMBING PENTHOUSE ROOF LEVEL ANGLE RELIEF VALVE FT FEET Z ZONE P-401 PLUMBING ENLARGED PLANS FU FIXTURE UNIT TEMPERATURE MIXING VALVE P-402 PLUMBING ENLARGED PLANS P-501 PLUMBING DETAILS G (LOW PRESSURE) NATURAL GAS UNION P-601 PLUMBING SCHEDULES GAL GALLONS P-801 PLUMBING WASTE & VENT RISER DIAGRAM REDUCER GD GARAGE DRAIN P-802 PLUMBING WASTE & VENT RISER DIAGRAM P-803 PLUMBING WATER RISER DIAGRAM GPM GALLONS PER MINUTE ECCENTRIC REDUCER (E.R.) P-804 PLUMBING WATER RISER DIAGRAM GV GATE VALVE SLEEVE HB HOSE BIBB HT HEAT TRACING PUMP HW HOT WATER M METER HWR HOT WATER RETURN HOSE BIBB HX HEAT EXCHANGER PLUMBING ITEMS TO BE COMPLETED ID INSIDE DIAMETER WATER HAMMER ARRESTER ITEM TITLE DESCRIPTION IE INVERT ELEVATION FLOOR DRAIN, AREA DRAIN, PLANT DRAIN, GARAGE DRAIN A MAIN LINE WAS SHOWN IN THE AREA BUT THE BRANCH PIPING AND IN INCH P-1 PARKING DECK DRAINS ALL PIPE SIZING REMAINS TO BE COMPLETED. IW INDIRECT WASTE FLOOR SINK NEW SNOHOMISH JS JANITOR SINK POINT OF CONNECTION (NEW TO EXISTING) A MAIN LINE WAS SHOWN IN THE AREA BUT THE BRANCH PIPING AND COUNTY P-2 MECH RM FLOOR DRAIN L LAVATORY ALL PIPE SIZING REMAINS TO BE COMPLETED. LDR LEADER COURTHOUSE MAX MAXIMUM PROPOSED VTR'S ARE SHOWN BUT THE SANITARY VENT PIPING WILL P-3 SANITARY VENTING BE SHOWN DURING THE CD PHASE WHEN THE FIXTURES ARE 2933 Rockefeller Ave. MG MEDIUM PRESSURE GAS COORDINATED AND IN THEIR FINAL LOCATION. Everett, Washington 98201 MH MANHOLE CONDENSATE DRAINAGE ORIGINATING FROM ALL THE FAN COIL UNITS MIN MINIMUM P-4 CONDENSATE DRAINAGE AND THE AIR HANDLERS ON THE ROOF REMAINS TO BE COMPLETED WHEN THIS EQUIPMENT IS COORDINATED AND IN IT'S FINAL LOCATION. Drawing Title MS MOP SINK (N) NEW THE LOWER ROOF DRAINS WILL PRODUCE RAINWATER WHICH THE PLUMBING LANDSCAPE CONSULTANT WOULD LIKE TO USE IN THE SOUTH NC NORMALLY CLOSED P-5 LOWER ROOF DRAINAGE PLANTER. ALL THE LOWER ROOF DRAINS EAST OF COLUMN LINE 4.1 LEGEND & AND SOUTH OF COLUMN B.5 WILL BE REDIRECTED TO THE PLANTER NIC NOT IN THIS CONTRACT THE EMERGENCY GENERATOR WILL BE EQUIPPED WITH A FUEL TANK. ABBREVIATIONS THE DESIGN TEAM REQUESTED A REMOTE FUEL OIL FILL. THE FINAL P-6 REMOTE FUEL OIL FILL LOCATION FOR THE FILL POINT AND THE ASSOCIATED PIPING TO THE GENERATOR WILL B INCLUDED LATER WHEN THESE ARE COORDINATED. Date: 05.22.2015 Job No: 1309100 Drawn By: SLB Checked By: RVW Drawing No. M P 0 4 : 1 5 : P-000 2 1 5 1 DESIGN 0 2 / 1 2 DEVELOPMENT / 5 NUMBERED NOTES 1 2" V UP. 9 4" SAN DN FROM ABOVE. 2 2" SAN DN FROM FD. 10 10" ST DN FROM ABOVE. 3 NOT USED. 11 3" SAN DN FROM MS. 4 4" SAN DN FROM COMBIE. 12 2" SAN DN FROM LAV. Heery International Inc. 4700 Millenia Blvd., 5 2" SAN DN FROM SK. 13 2" SAN DN FROM ABOVE. Suite 550 1 1.1 2 3 4 5 6 6.9 7 8 Orlando, FL 32839 6 4" SAN FROM ABOVE. 407.992.6300 7 UP TO CO. 8 SAN DN FROM SH. Consultants GAS UP TO METER 8"ø CIVIL MKA 1301 5TH AVE #3200 SEATTLE, WA 98101 PB101B PB101B T 206-292-1200 A PB101A PB101A 10"ø 7 LANDSCAPE 5 1 SITE WORKSHOP 6 222 ETRURIA ST #200 5 4 SEATTLE, WA 98109 T 206-285-3026 T S SAN STRUCTURAL 6" DOMESTIC WATER UP FCO FCO 8 G MKA 1301 5TH AVE #3200 SEATTLE, WA 98101 9 11 4 T 206-292-1200 4 4 2"V UP FROM SH 2 1 MECHANICAL WSP GROUP 600 UNIVERSITY ST, SUITE 500 SEATTLE, WA 98101 9 T 206-342-9900 B ELECTRICAL / TELCOM / AV 4 4 SPARLING 10 4100 194TH ST SW #400 LYNNWOOD, WA 98036 T 206-667-0555 FCO FCO SAN SAN LIGHTING 4 FCO FCO CANDELA 11 4100 194TH ST SW #400 LYNNWOOD, WA 98036 T 206-667-0511 4 4 13 SECURITY ELECTRONICS N A S GUIDEPOST SOLUTIONS 12 9 388 17TH STREET SUITE 230 6 6 OAKLAND, CA 94612 5 T 510-268-8373 2 Revisions C 9 NEW SNOHOMISH D COUNTY COURTHOUSE 2933 Rockefeller Ave. Everett, Washington 98201 Drawing Title PLUMBING UNDERGROUND PLAN E 0 4' 8' 16' SCALE: 1/8" = 1'-0" Key Plan F B A F.5 Date: 05.22.2015 Job No: 1309100 Drawn By: SLB Checked By: RVW 1.4 1.6 2.1 2.2 3.1 3.2 4.1 4.2 5.1 5.2 6.1 Drawing No. M P 4 1 : 2 5 : PB101A 2 1 5 1 DESIGN 0 2 / 1 2 DEVELOPMENT / 5 NUMBERED NOTES 1 SHEE SHEET PL100B FOR CONTINUATION. Heery International Inc. 4700 Millenia Blvd., Suite 550 Orlando, FL 32839 407.992.6300 Consultants CIVIL MKA 1 1.1 2 3 4 5 6 6.9 7 8 1301 5TH AVE #3200 SEATTLE, WA 98101 T 206-292-1200 P-A LANDSCAPE SITE WORKSHOP 222 ETRURIA ST #200 SEATTLE, WA 98109 T 206-285-3026 STRUCTURAL MKA 1301 5TH AVE #3200 SEATTLE, WA 98101 1 T 206-292-1200 MECHANICAL WSP GROUP 600 UNIVERSITY ST, SUITE 500 SEATTLE, WA 98101 T 206-342-9900 4"ø ELECTRICAL / TELCOM / AV SPARLING 4100 194TH ST SW #400 LYNNWOOD, WA 98036 T 206-667-0555 ST LIGHTING CANDELA SAN PIPING FOR MECHANICAL ROOM FLOOR DRAINS ABOVE 4100 194TH ST SW #400 LYNNWOOD, WA 98036 T 206-667-0511 P-B SECURITY ELECTRONICS GUIDEPOST SOLUTIONS 388 17TH STREET SUITE 230 SOI OAKLAND, CA 94612 T 510-268-8373 1 UP Revisions 10"ø 8"ø T S PB101B PB101B A PB101A PB101A NEW SNOHOMISH COUNTY COURTHOUSE 2933 Rockefeller Ave.
Recommended publications
  • ABSTRACT the Main Feature of a Conventional Terraced Housing Development Is Rows of Rectangular Shaped Houses with the Narrow Fa
    MAKING A RETURN ON INVESTMENT IN PASSIVE ARCHITECTURE TERRACED HOUSES DEVELOPMENT Wan Rahmah Mohd Zaki Universiti Teknologi Malaysia(UiTM) Malaysia E-mail: [email protected] Abdul Hadi Nawawi Universiti Teknologi MalaysiaQJiTM) Malaysia E-mail: [email protected] Sabarinah Sh Ahmad Universiti Teknologi MalaysiaQJiTM) Malaysia E-mail: [email protected] ABSTRACT The main feature of a conventional terraced housing development is rows of rectangular shaped houses with the narrow facade as the frontage. Consequently, this limits natural cross ventilation and daylight penetration into the middle of the houses; and cause for unnecessary energy consumption on mechanical cooling and artijicial lighting to make the living spaces comfortable for occupants. Such inconsideration is mainly attributed to the optimum configuration of houses which offers the most economic return desired by the developer. Passive Architecture (PA) design strategies can make terraced houses more conducive for occupants as well as gives reasonable returns to the developer. The idea is demonstrated on a hypothetical double storeys terraced scheme in a 2.5 acre site whereby it is transformed intofour types of PA terraced houses development. The Return on Invesfment of the PA terraced houses is ascertained for two situations, ie., (i) fwed sales price for all types of house; and (ii) added premium to PA terraced houses due to the positive unintended effects such as low density housing, etc. If critical criteria for demand and supply in housing remain constant, it is found that PA terraced housing development offers competitive returns to the developer relative to the returns for conventional terraced housing scheme. Keyworh: Orientation, Indoor Comfort and Operational Energy 1.0 INTRODUCTION 1.1 Housing and Energy The recent public awareness on sustainability calls for housing to not only serves as a basic shelter but also to be energy efficient, i.e., designed to make occupants need low operational energy.
    [Show full text]
  • PLUMBING PERMIT APPLICATION □ Residential □ Commercial □ New □ Alteration
    CITY OF BROOKFIELD For Office Use Only: PROP. TAX ID: Inspection Services Department 2000 North Calhoun RD, Brookfield, WI 53005 PERMIT # 262-796-6683 DATE ISSUED: http://www.ci.brookfield.wi.us □ BLDG PERMIT PLUMBING PERMIT APPLICATION □ Residential □ Commercial □ New □ Alteration Street Address: ________________________________________________________________________ Suite/Unit No. ___________________ Applicant is: □ Contractor □ Homeowner Owner/Occupant Name: Phone: Contractor: _______________________________________________________________ Phone: _____________________________________ Street Address: ________________________________________________ City: ________________________ State: ______ Zip: ___________ State Credential No: Check box if E-mail: you would like your permit emailed. For Office Use Only: FIXTURE OR ITEM QTY FIXTURE QTY FIXTURE ____ Air Admittance Valve ____ Interceptor Laterals & Connections ____ Area or Deck Drain ____ Kitchen Sink ____ Back Flow Preventer ____ Laundry Tub The prices listed below are for the first 100’. Over 100’ is an additional $.48 per foot. ____ Bar Sink ____ Lavatory QTY FEE TOTAL ____ Bathtub ____ Lawn Irrigation Sanitary Bldg. Drain $59.50 ____ Beer Tap ____ Manhole / Bldg. Drain Branch ( __________linear ft.) ____ Beverage Dispenser ____ Pedicure Chair Sanitary Bldg. Sewer ( __________linear ft.) $59.50 ____ Bidet ____ Pot Sink ____ Carbonator ____ Pressure Reduce Valve Storm Drain ( __________linear ft.) $59.50 ____ Case Drain ____ Prep Sink ____ Catch Basin ____ Roof Drain Water Service
    [Show full text]
  • Building a Safe Room Inside Your House COURTESY of NOAA/NSSL Includes Construction Plans and Cost Estimates
    FEMA 320 FIRST EDITION October 1998 COURTESY OF NASA COURTESY Taking Shelter From the Storm: Building a Safe Room Inside Your House COURTESY OF NOAA/NSSL Includes Construction Plans and Cost Estimates Federal Emergency Management Agency Mitigation Directorate 500 C Street, SW. • Washington, DC 20472 www.fema.gov Acknowledgments This booklet and the construction drawings it contains would not have been possible without the pioneering work of the Wind Engineering Research Center at Texas Tech University, the diligent efforts of the design team, and the constructive suggestions of the reviewers. Design Team Reviewers Paul Tertell, P.E. Dennis Lee Project Officer Hurricane Program Manager Program Policy and Assessment Branch Mitigation Division Mitigation Directorate FEMA Region VI FEMA Denton, Texas Washington, DC Bill Massey Clifford Oliver, CEM Hurricane Program Manager Chief, Program Policy and Assessment Branch Mitigation Division Mitigation Directorate FEMA Region IV FEMA Atlanta, Georgia Washington, DC TIm Sheckler, P.E. Dr. Ernst Kiesling, P.E. Civil Engineer Professor of Civil Engineering National Earthquake Program Office Wind Engineering Research Center Mitigation Directorate Texas Tech University FEMA Lubbock, Texas Washington, DC Dr. Kishor Mehta, P.E. Dr. Richard Peterson Director, Wind Engineering Research Center Chairman, Department of Geosciences Texas Tech University Texas Tech University Lubbock, Texas Lubbock, Texas Russell Carter, E.I.T. Larry Tanner, P.E., R.A. Research Associate Research Associate Wind Engineering Research Center Wind Engineering Research Center Texas Tech University Texas Tech University Lubbock, Texas Lubbock, Texas William Coulbourne, P.E. Richard Vognild, P.E Structural Engineer Director, Technical Services Greenhorne & O’Mara, Inc. Southern Building Code Congress International Greenbelt, Maryland Birmingham, Alabama Jay Crandell, P.E.
    [Show full text]
  • Basement Finishing and Remodeling Code
    BASEMENT FINISHING AND REMODELING CODE GUIDELINES Johnson County Kansas Unincorporated One of the objectives of the Johnson County Building Officials Association is to enhance construction uniformity and the adoption of common construction codes and procedures. This document is intended assist contractors and home owners in understanding the minimum code requirements for basement finish projects. It is also intended to provide guidance for obtaining permits and inspections. The information provided should not be considered a complete list of code requirements. Structural modifications, such as relocation of support columns, relocation of bearing walls, or reframing floor joists are not within the scope of this document. A registered design professional should be hired to provide review and design services for structural projects. Permit requirements may vary from city to city. Complete information is available in the codes and ordinances adopted by each City. Check with your city for complete requirements prior to obtaining a permit and before starting any work. BUILDING PERMITS AND PERMIT REQUIREMENTS Permits – A permit is required to finish or remodel a basement that involves construction of walls or installation or extension of electrical circuits, plumbing drains or vents, or ductwork. Exempt Work – Repair and maintenance work, such as, carpeting, painting, wall paper, receptacle replacement, fixture replacement (sinks, stools, lighting fixtures), vanities and cabinetry do not require a permit. Contractors – Most municipalities allow a homeowner to obtain a permit to do work in the house they own and occupy. If the homeowner is hiring a contractor to do the work, this document suggests that the contractor be required to obtain the permit.
    [Show full text]
  • Plastic Piping Handbook Every Solution Begins with a Good Idea
    Ideas that flow. Thermoplastic Flow Solutions ® ol r t Chem - Plastic Piping Handbook Every solution begins with a good idea. We’ve got ideas that flow NIBCO INC. directly to solutions for World Headquarters Plastic 1516 Middlebury Street your industrial piping Elkhart, IN 46516-4740 Piping applications. Ideas that USA make your installations Phone: 800.343.5455 Handbook easier and more cost- Fax: 800.541.3841 Technical Service: effective. Ideas that work, Phone: 888.446.4226 and ideas that last. Our International Office: ideas are strengthened by Phone: +1.574.295.3327 Fax: +1.574.295.3455 a sound foundation for www.chemtrol.com growth and a solid commitment to service. For ideas that fit your flow-control applications, call on us. We’re Chemtrol, a product line committed to innovation, growth, and superiority in thermoplastics— ideas whose time has come. CH-HB-1116-R071020 Corzan® is a registered trademark of The Lubrizol Corporation. Tru-Bloc® is a registered trademark of NIBCO INC. Chem-Pure® is a registered trademark of NIBCO INC. Chemcock® is a registered trademark of NIBCO INC. Kynar® is a registered trademark of Arkema Inc. Chemtrol® is a brand of www.chemtrol.com Ideas that flow. PLASTIC PIPING HANDBOOK “To the best of our knowledge the information contained in this publication is accurate; however, we do not assume any liability whatsoever for the accuracy or completeness of such information. Moreover, there is a need to reduce human exposure to many materials to the lowest practical limits in view of possible long-term adverse effects. To the extent that any hazards may have been mentioned in this publication, we neither suggest nor guarantee that such hazards are the only ones to exist.
    [Show full text]
  • Plumbing Permit Application
    CITY OF SOUTHFIELD Department of Building & Safety Engineering Plumbing Permit Application MINIMUM PERMIT FEE $90.00 (Includes $40.00 application fee) Date: ____________________________________________________ Plumbing Permit: ______________________________________ PLUMBING COMMERCIAL FEE QTY TTL Application Fee $40.00 1 40.00 Building Permit: _______________________________________ Registration If Required $15.00 Sidwell: _________________________________________________ Air Admittance Valve $15.00 Backflow Preventer: Job Address: ___________________________________________ Beverage Dispenser $15.00 Tenant: _______________________________Suite:___________ Coffee Maker $15.00 Fire Sprinkler $35.00 Owner: __________________________________________________ Lawn Sprinkler $50.00 Contractor: _____________________________________________ Miscellaneous $15.00 Source protection $35.00 Contractor Address: ___________________________________ Basement Waterproofing System $50.00 City: ___________________ State: ___________Zip: _________ Bath $15.00 Building Drain to Sewer $25.00 Contractor Phone: ____________________________________ Catch Basin/Manhole $50.00 Email: ___________________________________________________ Dishwasher $15.00 Disposal $15.00 Drinking Fountain $15.00 Floor Drain $15.00 PLUMBING RESIDENTIAL FEE QTY TTL Grease / Oil Interceptor $30.00 Application Fee $40.00 1 40.00 Hose Bibb $15.00 Registration If Required $15.00 Hot Water Supply Boilers w/Separate $35.00 Air Admittance Valve $15.00 Storage Tanks (over 52 gallons) Backflow
    [Show full text]
  • Design Guidelines for Stainless Steel in Piping Systems
    DESIGN GUIDELINES FOR STAINLESS STEEL IN PIPING SYSTEMS A DESIGNERS’ HANDBOOK SERIES NO 9024 Produced by Distributed by AMERICAN IRON NICKEL AND STEEL INSTITUTE INSTITUTE DESIGN GUIDELINES FOR STAINLESS STEEL IN PIPING SYSTEMS A DESIGNERS’ HANDBOOK SERIES NO 9024 Originally, this handbook was published in 1980 by the Committee of Stainless Steel Producers, American Iron and Steel Institute. The Nickel Institute republished the handbook in 2020. Despite the age of this publication the information herein is considered to be generally valid. Material presented in the handbook has been prepared for the general information of the reader and should not be used or relied on for specific applications without first securing competent advice. The Nickel Institute, the American Iron and Steel Institute, their members, staff and consultants do not represent or warrant its suitability for any general or specific use and assume no liability or responsibility of any kind in connection with the information herein. Nickel Institute [email protected] www.nickelinstitute.org DESIGN GUIDELINES FOR STAINLESS STEEL IN PIPING SYSTEMS Introduction This publication presents information on the design, fabrication, installation and economy of stainless steel in piping systems. The guidelines presented contain Contents important information for piping specialists and design engineers that will save money, time and effort in the several diverse industries utilizing piping systems. Stainless steels are defined as iron-base alloys con- Introduction ............................................................ 3 taining 10 percent or more chromium. They are en- The Selection of a Piping System ........................... 6 gineering materials selected primarily for their excellent Stainless Steel in Piping Systems ........................... 6 resistance to corrosion, their outstanding mechanical Advantages ........................................................
    [Show full text]
  • Facts About Insulation Requirements for Plastic Piping
    INSU L ATION Information from NAIMA: FACTS Facts About Insulation # Requirements for Plastic Piping 85 All current building energy codes and standards require pipe insulation on service hot water and HVAC piping. In this issue we discuss how much insulation is needed for domestic hot and cold service water systems and for HVAC systems in commercial and industrial buildings. While requirements vary, none of the model codes differentiates pipe insulation requirements based on pipe material. The amount of insulation needed depends on the design objectives of the system and the properties of the specific pipe material. Plastic piping for domestic hot and cold service water systems and for Common Plastic Piping HVAC systems in buildings is the Materials dominant piping material for residential construction, and is ABS (Acrylonitrile Butadiene also used routinely in commercial Styrene) and industrial applications. CPVC (Chlorinated Polyvinyl Energy codes do not differentiate Chloride insulation requirements based on PB (Polybutylene) plastic or metallic pipe wall PE (Polyethylene) material. PEX (Cross-linked Polyethylene) Plastic vs. Metal Piping PP (Polypropylene) Systems PVC (Polyvinyl Chloride) Compared to metallic piping PVDF (Polyvinylidene Fluoride) systems, plastic piping materials have a significantly lower thermal conductivity, which translates to of a given composition more or lower heat transfer between the less desirable for a given fluid and the ambient air. For application. As an example, a key some normally uninsulated piping property for hot systems is the systems, this can be advantageous. strength at temperature. Since all For example, city water lines plastics lose strength as entering a building will often temperature increases, this limits sweat due to the relatively cold the use of plastic piping to temperature of the water entering operating temperatures less than the building.
    [Show full text]
  • Pvc Piping Systems for Commercial and Industrial Applications
    PVC PIPING SYSTEMS FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS Plastic Pipe and Fittings Association © 2012 Plastic Pipe and Fittings Association (PPFA) Acknowledgments We would like to thank the following contributors to the Design Guide: The PVC and Thermoplastic Industrial Piping Systems (TIPS) Product Line Committees and member companies of the Plastic Pipe and Fittings Association (PPFA). In particular the following PPFA companies and individuals ably assisted in reviewing the text and tables and provided valuable comments which added greatly in producing a better and more accurate source document: Chuck Bush – Oatey Company Mike Cudahy – PPFA Staff Patrick Fedor – IPEX Bill Morris – Charlotte Pipe & Foundry Jack Roach – Mueller Industries Bill Weaver – Harvel Plastics Larry Workman – LASCO Fittings All text, tables and photos were prepared and or edited by David A. Chasis of Chasis Consulting, Inc. Using the Design Guide The Design Guide was created to assist engineers, installers, end-users, engineering students and building code officials in learning more of the dos and don’ts of PVC piping systems. The Design Guide is comprised of ten sections including: Introduction Features and Benefits Engineering Design Joining Methods Installation Testing and Repair Applications Building Codes, Standards, and Sample Specifications PVC Piping and the Environment Other Plastic Piping Systems In addition, in the back of the guide is the most complete appendix and glossary of PVC piping systems ever assembled. Other PPFA Educational Materials The PPFA offers a wide range of other educational materials developed to assist the engineering and construction industry to become more proficient in the use of the preferred piping system...plastics! On-site seminars, Webinars, CD-based seminars, workbooks, online tutorials and product and technical literature are available.
    [Show full text]
  • Plumbing Identification and Damage Assessment Guide
    Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with all types of existing systems to assure you and your company maintains vital and accurate information. Water System Identification To properly inspect the plumbing system, determine if the property has city water or well water. The below photos will assist you in determining what kind of water system the property has. Well Water Components City Water Components Plumbing Component Identification Plumbing components are items within the property that either provide or store water into the home or drain water from the home. The items that supply water to the home are kitchen and bathroom sinks, toilets, bathtubs, showers, interior and exterior faucets, hot water heater, water meter, and shutoff valves. Items that drain water from the home are drainage pipes and drainage traps. Exterior Water Meter Interior Water Meter Exterior Water Faucet Interior Water Faucet Plumbing Component Identification Continued… Water Meter Shut Off Valve Toilet Shut Off Valve Kitchen Faucet Bathroom Faucet Shower and Bathtub Toilet Plumbing Component Identification Continued… Plumbing Lines Plumbing Lines P- Trap P- Trap Refrigerator Ice Maker Line Basement Floor Drainage Plumbing Component Identification Continued… Conventional Water Heater Main Devices to Document: • Hot and Cold Water Supply Lines • Temp an d Pressure Relief Valve • Drain Va lve • Thermos tat • Gas Line Entry Point Tankless Water Heater Main Devices to Document: • Incoming Cold Water Line • Outgoing Hot Water Line Plumbing Assessment Determine the Type of Plumbing in the Property.
    [Show full text]
  • Craguns Resort Map.Pdf
    GULL LAKE . Steamboat Bay Irma’s Kitchen Dock Parking Grassy Knoll Lake Deck Lake Lake Access North Beach Lake Lake Access Wedding Site Access Access Access Lake Cabana Café Restaurant Access Hilltops Lounge Market 343-345 Lakeview Cabins Hospitality Bayview Villas Lake 684 Room 340 685 686 687 688 Access 689 Photo Opportunity Welcome to Cabin 115 resort on gull lake 1-800-CRAGUNS (1-800-272-4867) . LOCAL: 218-825-2700 . www.craguns.com DINING LAUNDRY FACILITIES MEETING ROOMS u u Lakeside Dining Room Poolside, by Room 230 u Lakeshore (Brown Signs) u Tech Center (Yellow Signs) Located at the Legacy Maps not to scale. Updated 10/17 68-2992 u Cabana Café u Shoreline Suites, One level below dining room One level below 200-211 Courses at Cragun’s: u by Room 280 u Tech 1: By Room 162, Irma’s Kitchen (Seasonal) Paul Bunyan (Blue Signs) u Audubon Room u u By Cabin 651, North of through Door E Bear Trap Lounge One level below indoor pool u Pavilion u Outdoor Pool (Summer Only) u Tech 2: Under Rooms 204-207, Legacy Grille (Seasonal) Pioneer (Black Signs) u Legacy Grille Halfway down dining room through Door D POP MACHINES Turn left at Cragun’s entrance FIREWOOD stairs, on right Tech 3: Under Rooms 200-203, u Lobby through Door C or B onto CR 77 toward Brainerd. Please call Ext. 8700 for u Dutch (Black Signs) u Drive approximately one mile Marina u Shoreline Meeting Room delivery and instructions. Halfway down dining room and turn left onto u The Centre At base of Shoreline Suite stairs, on left, OR halfway down CR 70.
    [Show full text]
  • Building Numbers, Street Addresses, Room Numbers
    www.facilities.ufl.edu BUSINESS AFFAIRS PLANNING DESIGN AND CONSTRUCTION PDC PROJECT MANAGEMENT GUIDE PMG-E14: BUILDING NUMBERS, STREET ADDRESSES, AND ROOM NUMBERS PURPOSE: To communicate guidelines and procedures for numbering facilities, establishing street addresses, and assigning space/room numbers. A. Introduction Planning Design and Construction (PDC) is responsible for numbering, tracking, and reporting facilities-related information for the University. PDC utilizes CAD/BIM technology in the data-basing of facilities information, so a meaningful numbering and CAD/BIM standard must be followed. Additionally, PDC is required to annually submit the Physical Facilities Space File to the Board of Governors and must take necessary actions to ensure the incorporation of required data elements into its operating database. Data elements are based on the Postsecondary Education Facilities Inventory and Classification Manual, 2006. B. Street Addresses A request for a street address should be made by the PDC Project Manager (PM) once a project’s physical locale has been established and before site work begins. At a minimum, the building footprint and major entry doors should be settled to establish an appropriate address. Requests for a new address will be coordinated through PDC Space Management & Analysis (SMA) staff. Upon assignment of the street address, the new address will be entered in UF-STARS for local notification to PeopleSoft, Purchasing, EH&S, and the UF community. The Alachua County E911 office will be responsible for notification to the Alachua County Call Center, USPS, major package carriers, and other external entities. New addresses outside of Alachua County should be requested by the PDC PM through PDC SMA, which will work with the appropriate local authorities.
    [Show full text]