Minimum Plumbing Fixture Clearances Ada Shower

Total Page:16

File Type:pdf, Size:1020Kb

Minimum Plumbing Fixture Clearances Ada Shower REVISION 1'-6" 1'-0" 1'-6" PB SUBMISSION ADA BATH DETAILS 3'-0" 3'-6" 1'-0" ADA 1'-0" DATE 8-28-19 SHOWER 5-20-19 No. 3'-0" 56" MIN . CLEARANCE 6'-0" 3'-6" 3'-8" 3'-8" 5'-0" MIN 3'-2" 1'-0" 3'-0" 3'-0" 2'-10" 2'-10" 18" 2'-8" 2'-6" NEW 2'-6" WALL. 2'-0" 1'-10" MIN 6" 1'-6" 1'-6" 1'-6" ALLOWABLE RANGE OF SEE 3'-4" MIN.TO 4'-0" MAX. 2'-0" 1'-0" WALL 4" TYPES 1'-6" 7" - 9" 30"Wx 48"L CLEAR FLOOR SPACE ON PLAN ELEVATION - TOILET ELEVATION - SINK PLAN A1, NEW 3068 TYP. DOOR W/D 2 TYPICAL ADA FIXTURES ELEVATIONS W/ ADA 3'-10" W/D HARDWARE A6 SCALE: 1/4" = 1'-0" TOILET ACCESSORY LEGEND GENERAL NOTES: PAPER TOWEL DISPENSER 1. INSTALL CERAMIC OR VINYL TILE ON THE FLOORS AND USE A 42" GRAB BAR SANITARY NAPKIN DISPOSAL 167 STAGE ROAD WASTE RECEPTACLE CERAMIC OR VINYL TILE BASE. 36" GRAB BAR TOILET PAPER DISPENSER RESTROOM SIGN IN BRAILLE 2. PROVIDE WOOD BLOCKING FOR INSTALLATION OF TOILET ACCESSORIES. MONROE, NEW YORK 10950 EXISTING OPENING EXISTING WALL, TYP. ADA TILT MIRROR SOAP DISPENSER 3. SEE ELECTRICAL PLANS FOR LOCATIONS OF POWER FOR THE COMPLIES W/ ADA MIN. 24" x 42" UNDER LAV PIPE INSULATION ELECTRONIC FUNCTIONS. WWW.NIEMOTKOARCHITECTS.COM CLEARANCES OF 32 INCHES CLEAR, TYP. DAVID NIEMOTKO ARCHITECTS, P.C. 1 ADA BATHROOM PLAN (845) 774-7523 PH.&FAX 401-2891 CELL A6 SCALE: 1/2" =1'-0" 3" VTR - EXTEND 18" MIN. PER CODE ROOF NOTE FOR AUTHENTICITY 6'-2" 3"V SEAL MUST BE 4" 4" 4" ORIGINAL AND WALL BATH ROOM SIGNATURE MUST BE IN COLOR - 2"V BOTH CANNOT TUB WASHER WASHER BE COPIED 1'-0 1/2" 5" 2"V. 1.5"V. DRAIN - DRAIN - 1.5"V. 1.5" V 1.5" V 21" WC WASHER WASHER SH. 2"W 2"W CLEARANCE 2ND FL. 8'-9" 2"W 3"W WALL 3"W 3"W 9" MIN. 19" MIN. 27" MIN. LAVATORIES 6" MAX. 9" MIN. 3"V 1'-3" 1'-3" KITCHEN WALL WALL 2"V WORK HEIGHT 34" MAX. 32" PREFERRED 30" MIN. FRESH AIR VENT 6'-2" TO EXTERIOR AS PER TUB 1.5"V. 1.5"V. 2'-6" WALL CODE 2'-6" 2'-0" 2"W 2"W 21" CLEARANCE 21" CLEARANCE IN 1ST FL. 1'-0 1/2" 5" FRONT OF CLEARANCE TUB OPENING TO SEWER - 1 WALL WALL 4"W - SLOPE 4" PER FOOT MIN. PROVIDE HOUSE NOTE: ALL VENTING AND DRAIN PIPING SHALL BE PVCTRAP BEFORE EXITING THE HOUSE 8'-9" REST-HAVEN WATER CLOSETS SHOWERS PLUMBING-DETAILS BASEMENT 236-HIGH-STREET ADULT-CARE-FACILITY MONROE,-NY-10950 236-HIGH-STREET-LLC 9" MIN. 6" MAX. ADA-BATH-AND-KITCHEN-DETAILS 30" MIN. KNEE SPACE 3 MINIMUM PLUMBING FIXTURE CLEARANCES 4 PLUMBING RISER DIAGRAM - VENT & WASTE A6 SCALE: 1/4" = 1'-0" A6 SCALE: NTS 5 TYPICAL ADA KITCHEN REQUIREMENTS A6 SCALE: NTS NOTES SHEET TITLE: PROJECT: CLIENT: 1. ALL WORK MUST COMPLY WITH THE NYS BUILDING CODE, PLUMBING CODE AND ALL LOCAL ORDINANCES. SCALE: AS_NOTED 2. COVER ALL EXPOSED HOT WATER PIPING W/ 1/2" WALL, FOAM INSULATION, I.E. ARMORFLEX OR DRFM: APPROVED EQUAL, TYP. 3. UNDERSLAB SANITARY PIPING CAN BE PVC, SCHEDULE 40, YET MUST COMPLY WITH THE LOCAL CODE. CAD # 4. SLOPE 4 INCH WASTER @ 1/4" PER FOOT. JOB # JOB 5. PIPE PENETRATIONS THROUGH THE FOUNDATION WALL SHALL BE 2 PIPE SIZES GREATER THAT THE PIPE. THE OPENING SHALL BE "SLEEVED" AND THE VOID SHALL BE FILLED WITH A FLEXIBLE, WATERPROOF MATERIAL, PLOT DATE: 5/31/19 I.E "LINK-SEAL". SHEET No. A-6 PLAN-6-OF- 7.
Recommended publications
  • PLUMBING PERMIT APPLICATION □ Residential □ Commercial □ New □ Alteration
    CITY OF BROOKFIELD For Office Use Only: PROP. TAX ID: Inspection Services Department 2000 North Calhoun RD, Brookfield, WI 53005 PERMIT # 262-796-6683 DATE ISSUED: http://www.ci.brookfield.wi.us □ BLDG PERMIT PLUMBING PERMIT APPLICATION □ Residential □ Commercial □ New □ Alteration Street Address: ________________________________________________________________________ Suite/Unit No. ___________________ Applicant is: □ Contractor □ Homeowner Owner/Occupant Name: Phone: Contractor: _______________________________________________________________ Phone: _____________________________________ Street Address: ________________________________________________ City: ________________________ State: ______ Zip: ___________ State Credential No: Check box if E-mail: you would like your permit emailed. For Office Use Only: FIXTURE OR ITEM QTY FIXTURE QTY FIXTURE ____ Air Admittance Valve ____ Interceptor Laterals & Connections ____ Area or Deck Drain ____ Kitchen Sink ____ Back Flow Preventer ____ Laundry Tub The prices listed below are for the first 100’. Over 100’ is an additional $.48 per foot. ____ Bar Sink ____ Lavatory QTY FEE TOTAL ____ Bathtub ____ Lawn Irrigation Sanitary Bldg. Drain $59.50 ____ Beer Tap ____ Manhole / Bldg. Drain Branch ( __________linear ft.) ____ Beverage Dispenser ____ Pedicure Chair Sanitary Bldg. Sewer ( __________linear ft.) $59.50 ____ Bidet ____ Pot Sink ____ Carbonator ____ Pressure Reduce Valve Storm Drain ( __________linear ft.) $59.50 ____ Case Drain ____ Prep Sink ____ Catch Basin ____ Roof Drain Water Service
    [Show full text]
  • Basement Finishing and Remodeling Code
    BASEMENT FINISHING AND REMODELING CODE GUIDELINES Johnson County Kansas Unincorporated One of the objectives of the Johnson County Building Officials Association is to enhance construction uniformity and the adoption of common construction codes and procedures. This document is intended assist contractors and home owners in understanding the minimum code requirements for basement finish projects. It is also intended to provide guidance for obtaining permits and inspections. The information provided should not be considered a complete list of code requirements. Structural modifications, such as relocation of support columns, relocation of bearing walls, or reframing floor joists are not within the scope of this document. A registered design professional should be hired to provide review and design services for structural projects. Permit requirements may vary from city to city. Complete information is available in the codes and ordinances adopted by each City. Check with your city for complete requirements prior to obtaining a permit and before starting any work. BUILDING PERMITS AND PERMIT REQUIREMENTS Permits – A permit is required to finish or remodel a basement that involves construction of walls or installation or extension of electrical circuits, plumbing drains or vents, or ductwork. Exempt Work – Repair and maintenance work, such as, carpeting, painting, wall paper, receptacle replacement, fixture replacement (sinks, stools, lighting fixtures), vanities and cabinetry do not require a permit. Contractors – Most municipalities allow a homeowner to obtain a permit to do work in the house they own and occupy. If the homeowner is hiring a contractor to do the work, this document suggests that the contractor be required to obtain the permit.
    [Show full text]
  • Summary of the Reduction of Lead in Drinking Water Act and Frequently Asked Questions
    Summary Of The Reduction Of Lead In Drinking Water Act And Frequently Asked Questions The Reduction of Lead in Drinking Water Act was enacted on January 4, 2011 to amend Section 1417 of the Safe Drinking Water Act (SDWA or Act) respecting the use and introduction into commerce of lead pipes, plumbing fittings or fixtures, solder and flux. The Act established a prospective effective date of January 4, 2014, which provided a three year timeframe for affected parties to transition to the new requirements. In anticipation of these changes taking effect, EPA is providing the following summary of the requirements of the lead ban provisions in Section 1417 and some answers to frequently asked questions related to the amendments to assist manufacturers, retailers, plumbers and consumers in understanding the changes to the law. Outreach On August 16, 2012, EPA held a public webinar with stakeholders to discuss the Reduction of Lead in Drinking Water Act and the potential ramifications that this change in law may have. Participants included public utilities, government agencies, plumbing manufacturers, plumbing retailers and trade associations. At the end of this webinar, EPA solicited comments from the attendees on issues and concerns related to the new requirements. The webinar proceedings and the solicited input were used in formulating an initial set of Frequently Asked Questions (FAQs) that were published for public comment on May 23, 2013. This document, including revised answers to frequently asked questions, is intended to help the public understand the statutory requirements, EPA intends to further clarify and refine these and other issues related to these provisions in a future rulemaking.
    [Show full text]
  • Plumbing Permit Application
    CITY OF SOUTHFIELD Department of Building & Safety Engineering Plumbing Permit Application MINIMUM PERMIT FEE $90.00 (Includes $40.00 application fee) Date: ____________________________________________________ Plumbing Permit: ______________________________________ PLUMBING COMMERCIAL FEE QTY TTL Application Fee $40.00 1 40.00 Building Permit: _______________________________________ Registration If Required $15.00 Sidwell: _________________________________________________ Air Admittance Valve $15.00 Backflow Preventer: Job Address: ___________________________________________ Beverage Dispenser $15.00 Tenant: _______________________________Suite:___________ Coffee Maker $15.00 Fire Sprinkler $35.00 Owner: __________________________________________________ Lawn Sprinkler $50.00 Contractor: _____________________________________________ Miscellaneous $15.00 Source protection $35.00 Contractor Address: ___________________________________ Basement Waterproofing System $50.00 City: ___________________ State: ___________Zip: _________ Bath $15.00 Building Drain to Sewer $25.00 Contractor Phone: ____________________________________ Catch Basin/Manhole $50.00 Email: ___________________________________________________ Dishwasher $15.00 Disposal $15.00 Drinking Fountain $15.00 Floor Drain $15.00 PLUMBING RESIDENTIAL FEE QTY TTL Grease / Oil Interceptor $30.00 Application Fee $40.00 1 40.00 Hose Bibb $15.00 Registration If Required $15.00 Hot Water Supply Boilers w/Separate $35.00 Air Admittance Valve $15.00 Storage Tanks (over 52 gallons) Backflow
    [Show full text]
  • TRAPS No. IPC IRC Description
    MATERIALS Traps TRAPS 4 MAX 24" 1 3 2 MAX 30" No. IPC IRC Description Vertical distance from fi xture to the 1 1002.1 P3201.6 trap weir can not exceed 24". Horizontal distance from the fi xture 2 1002.1 P3201.6 outlet to the centerline of the trap inlet can not exceed 30". Each fi xture trap must have a liquid 3 1002.4 P3201.2 seal of not less than 2" and not more than 4". Combination plumbing fi xture can share a trap as long as one compartment is P3201.6 4 1002.1 (2) not more than 6" deeper than the other Exc. 2 compartment and compartment outlets are 30" or less apart. YOU SHOULD KNOW: IPC 908.1, 1002.5 AND IRC P3201.7 • IPC 908.1, IRC P3107.1: An individual vent is permitted to vent two traps or trapped fi xtures as a common vent. • IPC 1002.5, IRC P3201.7 & TABLE P3201.7: Fixture trap size shall be suffi cient to drain the fi xture rapidly and not less than the size located in Table 709.1. For additional resources visit www.code-ref.com 7 PERMITS AND INSPECTION PERMITS (IRC R105 • IPC 106) REQUIRED (IRC R 105.1 • IPC 106.1) • Construction, alteration, removal, or repair of any plumbing system. APPLICATION (IRC R105.3 • IPC 106.3) • Submit application to local building department. • Submit two or more sets of all supporting construction documents. • Code offi cial can waive the requirement for submitting supporting construction documents. ISSUANCE (IRC R105.3.2, IRC 105.6 • IPC 106.5) • Typically issued for a period of 180 days.
    [Show full text]
  • Plumbing Identification and Damage Assessment Guide
    Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with all types of existing systems to assure you and your company maintains vital and accurate information. Water System Identification To properly inspect the plumbing system, determine if the property has city water or well water. The below photos will assist you in determining what kind of water system the property has. Well Water Components City Water Components Plumbing Component Identification Plumbing components are items within the property that either provide or store water into the home or drain water from the home. The items that supply water to the home are kitchen and bathroom sinks, toilets, bathtubs, showers, interior and exterior faucets, hot water heater, water meter, and shutoff valves. Items that drain water from the home are drainage pipes and drainage traps. Exterior Water Meter Interior Water Meter Exterior Water Faucet Interior Water Faucet Plumbing Component Identification Continued… Water Meter Shut Off Valve Toilet Shut Off Valve Kitchen Faucet Bathroom Faucet Shower and Bathtub Toilet Plumbing Component Identification Continued… Plumbing Lines Plumbing Lines P- Trap P- Trap Refrigerator Ice Maker Line Basement Floor Drainage Plumbing Component Identification Continued… Conventional Water Heater Main Devices to Document: • Hot and Cold Water Supply Lines • Temp an d Pressure Relief Valve • Drain Va lve • Thermos tat • Gas Line Entry Point Tankless Water Heater Main Devices to Document: • Incoming Cold Water Line • Outgoing Hot Water Line Plumbing Assessment Determine the Type of Plumbing in the Property.
    [Show full text]
  • Definitions A-I Definitions
    2015 UPC Code - Chapter 2 Definitions A-I Definitions 201.1 Applicability. For the purpose of this code, the following terms have the meanings indicated in this chapter. 202.0 Definition of Terms. 202.1 General. The definitions of terms are arranged alphabetically according to the first word of the term. – A – ABS. Acrylonitrile-butadiene-styrene. Accepted Engineering Practice. That which conforms to technical or scientific-based principles, tests, or standards that are accepted by the engineering profession. Accessible. Where applied to a fixture, connection, appliance, or equipment, “accessible” means having access thereto, but which first may require the removal of an access panel, door, or similar obstruction. Accessible, Readily. Having a direct access without the necessity of removing a panel, door, or similar obstruction. Air Break. A physical separation which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected. Air Gap, Drainage. The unobstructed vertical distance through the free atmosphere between the lowest opening from a pipe, plumbing fixture, appliance, or appurtenance conveying waste to the flood-level rim of the receptor. Air Gap, Water Distribution. The unobstructed vertical distance through the free atmosphere between the lowest opening from a pipe or faucet conveying potable water to the flood-level rim of a tank, vat, or fixture. Alternate Water Source.Nonpotable source of water that includes but not limited to gray water, on-site treated non-potable water, rainwater, and reclaimed (recycled) water. Anchors. See Supports. Anesthetizing Location. An area of a facility that has been designated to be used for the administration of general anesthesia.
    [Show full text]
  • Chapter Vi Building Plumbing
    CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems are covered. An understanding of basic aspects of the plumbing code is essential. Every city has adopted a plumbing code to protect the health and safety of its people. Building departments enforce these codes and arrange inspections of plumbing work as it's completed. Cost of plumbing systems in most homes is about 10% of the total construction cost. Every plumbing system is divided in to three parts: 1) The Drainage and vent system 2) The water service pipes and distributing pipes 3) The plumbing fixture. 6.2. WATER DEMAND The demand that will be placed on a water supply source is the first step to be calculated when designing it. The size of water supply pipes will depend on: 1) The type of flush devices to be used on the fixtures 2) The water pressure in pounds per square inch at the source 3) The length of the pipe in the building 4) The number and kinds of fixtures installed 5) The number of fixtures expected to be used at any time. the average daily water demand for several facilities is shown on Table 6.1. Table 6.1. Average Daily Water Demand Type of facility Water Demand (Gallons/day) Airport (per passenger) 3-5 Resorts (day and night, with limited plumbing, per 50 camper) Factories (per person per shift) 15-35 Highway rest areas (per person) 5 Hotels with private baths (two persons/room) 60 Multi family dwelling (per resident) 60 Hospitals (per bed) 75-125 A more complete table can be found in [1 ] The average hot water demand in the USA is assumed to be 20 gallons per person per day (gppd) for a family of two persons.
    [Show full text]
  • Chapter 4 Fixtures, Faucets and Fixture Fittings
    Color profile: Generic CMYK printer profile Composite Default screen CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 402.2 Materials for specialty fixtures. Materials for specialty GENERAL fixtures not otherwise covered in this code shall be of stainless 401.1 Scope. This chapter shall govern the materials, design steel, soapstone, chemical stoneware or plastic, or shall be and installation of plumbing fixtures, faucets and fixture fit- lined with lead, copper-base alloy, nickel-copper alloy, corro- tings in accordance with the type of occupancy, and shall pro- sion-resistant steel or other material especially suited to the vide for the minimum number of fixtures for various types of application for which the fixture is intended. occupancies. 402.3 Sheet copper. Sheet copper for general applications 401.2 Prohibited fixtures and connections. Water closets shall conform to ASTM B 152 and shall not weigh less than 12 having a concealed trap seal or an unventilated space or having ounces per square foot (3.7 kg/m2). walls that are not thoroughly washed at each discharge in 402.4 Sheet lead. Sheet lead for pans shall not weigh less than accordance with ASME A112.19.2M shall be prohibited. Any 4 pounds per square foot (19.5 kg/m2) coated with an asphalt water closet that permits siphonage of the contents of the bowl paint or other approved coating. back into the tank shall be prohibited. Trough urinals shall be prohibited. 401.3 Water conservation. The maximum water flow rates SECTION 403 and flush volume for plumbing fixtures and fixture fittings MINIMUM PLUMBING FACILITIES shall comply with Section 604.4.
    [Show full text]
  • PLUMBING DICTIONARY Sixth Edition
    as to produce smooth threads. 2. An oil or oily preparation used as a cutting fluid espe cially a water-soluble oil (such as a mineral oil containing- a fatty oil) Cut Grooving (cut groov-ing) the process of machining away material, providing a groove into a pipe to allow for a mechani cal coupling to be installed.This process was invented by Victau - lic Corp. in 1925. Cut Grooving is designed for stanard weight- ceives or heavier wall thickness pipe. tetrafluoroethylene (tet-ra-- theseveral lower variouslyterminal, whichshaped re or decalescensecryolite (de-ca-les-cen- ming and flood consisting(cry-o-lite) of sodium-alumi earthfluo-ro-eth-yl-ene) by alternately dam a colorless, thegrooved vapors tools. from 4. anonpressure tool used by se) a decrease in temperaturea mineral nonflammable gas used in mak- metalworkers to shape material thatnum occurs fluoride. while Usedheating for soldermet- ing a stream. See STANK. or the pressure sterilizers, and - spannering heat resistantwrench and(span-ner acid re - conductsto a desired the form vapors. 5. a tooldirectly used al ingthrough copper a rangeand inalloys which when a mixed with phosphoric acid.- wrench)sistant plastics 1. one ofsuch various as teflon. tools to setthe theouter teeth air. of Sometimesaatmosphere circular or exhaust vent. See change in a structure occurs. Also used for soldering alumi forAbbr. tightening, T.F.E. or loosening,chiefly Brit.: orcalled band vapor, saw. steam,6. a tool used to degree of hazard (de-gree stench trap (stench trap) num bronze when mixed with nutsthermal and bolts.expansion 2. (water) straightenLOCAL VENT.
    [Show full text]
  • SOHO Design in the Near Future
    Rochester Institute of Technology RIT Scholar Works Theses 12-2005 SOHO design in the near future SooJung Lee Follow this and additional works at: https://scholarworks.rit.edu/theses Recommended Citation Lee, SooJung, "SOHO design in the near future" (2005). Thesis. Rochester Institute of Technology. Accessed from This Thesis is brought to you for free and open access by RIT Scholar Works. It has been accepted for inclusion in Theses by an authorized administrator of RIT Scholar Works. For more information, please contact [email protected]. Rochester Institute of Technology A thesis Submitted to the Faculty of The College of Imaging Arts and Sciences In Candidacy for the Degree of Master of Fine Arts SOHO Design in the near future By SooJung Lee Dec. 2005 Approvals Chief Advisor: David Morgan David Morgan Date Associate Advisor: Nancy Chwiecko Nancy Chwiecko Date S z/ -tJ.b Associate Advisor: Stan Rickel Stan Rickel School Chairperson: Patti Lachance Patti Lachance Date 3 -..,2,2' Ob I, SooJung Lee, hereby grant permission to the Wallace Memorial Library of RIT to reproduce my thesis in whole or in part. Any reproduction will not be for commercial use or profit. Signature SooJung Lee Date __3....:....V_6-'-/_o_6 ____ _ Special thanks to Prof. David Morgan, Prof. Stan Rickel and Prof. Nancy Chwiecko - my amazing professors who always trust and encourage me sincerity but sometimes make me confused or surprised for leading me into better way for three years. Prof. Chan hong Min and Prof. Kwanbae Kim - who introduced me about the attractive
    [Show full text]
  • Illinois Plumbing Code
    DPH 77 ILLINOIS ADMINISTRATIVE CODE 890 SUBCHAPTER r TITLE 77: PUBLIC HEALTH CHAPTER I: DEPARTMENT OF PUBLIC HEALTH SUBCHAPTER r: WATER AND SEWAGE PART 890 ILLINOIS PLUMBING CODE SUBPART A: DEFINITIONS AND GENERAL PROVISIONS Section 890.110 Applicability 890.120 Definitions 890.130 Incorporated and Referenced Materials 890.140 Compliance with this Part 890.150 Workmanship 890.160 Used Plumbing Material, Equipment, Fixtures 890.170 Sewer and/or Water Required 890.180 Sewer and Water Pipe Installation 890.190 Piping Measurements 890.200 Operation of Plumbing Equipment SUBPART B: PLUMBING MATERIALS Section 890.210 Materials 890.220 Identification (Repealed) 890.230 Safe Pan Material and Construction SUBPART C: JOINTS AND CONNECTIONS Section 890.310 Tightness 890.320 Types of Joints 890.330 Special Joints 890.340 Use of Joints 890.350 Unions 890.360 Water Closet and Pedestal Urinal 890.370 Prohibited Joints and Connections in Drainage Systems 890.380 Increasers and Reducers SUBPART D: TRAPS AND CLEANOUT (T/C-1) DPH 77 ILLINOIS ADMINISTRATIVE CODE 890 SUBCHAPTER r Section 890.410 Fixture Traps/Continuous Waste 890.420 Pipe Cleanouts 890.430 Cleanout Equivalent 890.440 Acid-Proof Traps SUBPART E: INTERCEPTORS − SEPARATORS AND BACKWATER VALVES Section 890.510 Grease Interceptor Requirements 890.520 Gasoline, Oil and Flammable Liquids 890.530 Special Waste Interceptors 890.540 Laundries (Repealed) 890.550 Backwater Valves − Sanitary System and Storm System (Repealed) SUBPART F: PLUMBING FIXTURES Section 890.610 General Requirements − Material
    [Show full text]