STANDARD DETAILS FOR METAL ROOFING AND SIDING
AGRICULTURAL LIGHT COMMERCIAL RESIDENTIAL
THE BLUE BOOK Due to Product improvements, changes and other factors, Fabral reserves the right to change or delete infor- mation herein without prior notice or obligation to make changes in products previously purchased.
The details and written instructions described in this manual are suggested installation methods to ensure a quality application of our products, and should be considered as a guideline only. FABRAL recognizes that installation techniques can vary based upon builder and geographical preferences, and that there are other acceptable ways to install our products.
Fabral.com TABLE OF CONTENTS Introduction...... 2 Fabral Core...... 3 Installation Instructions...... 4-5 Steel Panel Profiles...... 6-8 Aluminum Panel Profiles...... 9 Estimating & Roof Types...... 10 Load Tables & Testing...... 11 Building Details Post Frame...... 12 Residential...... 13 Post Frame Flashing Details Endlap & Rain Carrying Table...... 14 Flashings/Trim Post Frame...... 15-18 Residential...... 19 Mighti-Rib...... 20 General Notes...... 21 System Components...... 22-23 Accessories...... 24-25 Trim Details Post Frame Eave & Box Eave...... 26 Vented Eave & Endwall...... 27 Endwall- Notched & Sidewall...... 28 Dormer Valley & Valley...... 29 Gambrel & Transition...... 30 Box Gable...... 31 Gables...... 32 Flying Gable Detail & Monoslope Ridge...... 33 Ridge/Peak- Non Vented & Vented Ridge...... 34 Alternate Vented Ridge & Base Guard...... 35 Door Header & Door Jamb...... 36 Door Jambs...... 37 Overhead Door Jambs...... 38 Sliding Door Jamb, Header & Base...... 39 Window Sill, Header & Jamb & Translucent Panel...... 40 Inside Corner & Outside Corners...... 41 Residential Vented Eave & Eave...... 42 Endwall & Sidewall...... 43 Valley & Dormer Valley...... 44 Gambrel & Transition...... 45 Pipe Boot & Skylight...... 46 Skylight Section A-A & B-B...... 47 Chimney Details...... 48 Chimney Endwall & Ridge/Hip...... 49 Vented Ridge & Gable...... 50 Paint System & Warranties...... 51 Complete Contact Information...... 52 INTRODUCTION
The Right Tools. This Standard Details Manual, AKA the Blue Book, is the right tool to have at your fingertips. By knowing you have access to all of the right information from proper storage and installation instructions to trim and flashing details, you can be confident installing your Fabral materials. In addition, the Blue Book references the complete system components and accessories allowing you plan ahead. Use the Blue Book, and call us when further support is needed. AGRICULTURAL
Fabral is the solution for your agricultural applications. We know that your barns and buildings must stand up to all weather conditions and last through the years.
LIGHT COMMERCIAL
For your light commercial needs, Fabral offers metal roofing and siding to match the various building types.
RESIDENTIAL
Homeowners feel proud and confident with Fabral metal roofing for the durability and sophisticated appearance.
2 Fabral.com You challenge us. And we like it. Your vision for a building and what you want to achieve makes us think harder. It’d be easy to say - “That won’t work.” Instead we go with - “Let’s see what we can do.” As the leading provider of metal for building envelope solutions, we push the envelope.
We like it when you bring us a problem because we know we’ll find the solution. We have the products, the manufacturing and the know-how. We offer everything you need for the total building envelope solution. At our core, we relish a challenge.
CUSTOMER CARE SYSTEM EDUCATION SUPPORT PROJECT CONSULTING TECHNICAL SUPPORT
To learn more, contact us at Fabral.com. 3 INSTALLATION INSTRUCTIONS
Building Design and Construction 2x4 or 1x4 purlins should be fastened through the decking and In order to ensure the anticipated performance and longevity, into the rafters. This will provide a solid framework for attaching protect metal panels from potentially corrosive situations and ma- the metal panels. For more detailed information on re-roofing terials. When treated lumber will be in direct contact with metal applications, consult FABRAL Technical Bulletin #721, Re-Roofing panels or flashings please note the following: Galvanized steel With Metal. Load tables are available for all FABRAL panels; con- is compatible with the CCA (Chromated Copper Arsenate) pres- tact FABRAL for additional information. sure-treated lumber that was predominantly used before 2004, but not with the older Penta treated lumber or the new ACQ (Al- Roofing kaline Copper Quartenary), CA (Copper Azole), or CBA (Copper Panel sidelaps should face away from wind driven rain. To Boron Azole). Stainless steel or other special treated fasteners accomplish this, begin by installing the first sheet square with should be used into these non-compatible pressure treated lum- the eave and gable at the down wind end of the roof, farthest bers. Aluminum must be separated from contact with all treated away from the source of prevailing winds or away from the primary wood since the soluble copper in the preservative is corrosive to viewing location. aluminum. Likewise, dissimilar metals also require a protective In applications requiring a panel endlap, please refer to the barrier between them to prevent galvanic corrosion. Request detailed instructions in this booklet. For best results, lap panels as FABRAL Technical Bulletins #803, 106, and 107 for more informa- shown and install in the indicated sequence. ALL ENDLAPS RE- tion on treated lumber and dissimilar metals. QUIRE SEALANT. WHEN WEATHER-TIGHTNESS IS CRITICAL, PLASTIC, BUILDERS’ FELT, BITUMINOUS PAINT, CAULKING, USE SEALANT TAPE IN ALL SIDELAPS. OR GASKET MATERIAL MAY BE USED TO SEPARATE PANELS To provide a drip edge, allow an overhang of 1 to 2 inches at FROM TREATED WOOD AND DISSIMILAR METALS. When us- the eave. At the gable edge, use a gable or sidewall flashing. This ing aluminum panels in direct contact with steel, use a separator will keep weather out, prevent lifting in high winds, and provide a as described above and fasten with Stainless Steel screws. neat, finished appearance. The trim and roofing sheet should be Fertilizer, lime, acids, feeds, manure, soils, and many other fastened every 12 to 24 inches along the gable edge. Do not step compounds also cause corrosion in metal panels. Contact be- on panel ribs or on trim pieces to prevent kinking. tween metal panels and any potentially corrosive materials should be prevented. Roof Pitch Porous insulation materials may absorb and retain moisture, The metal roofing panels shown in this manual require a min- and should not be used in direct contact with metal panels. Use a imum slope of 2½ʺ per foot to ensure proper drainage. Refer to vapor barrier such as polyethylene plastic or 30-lb felt to prevent the rain-carrying table in this booklet for the maximum allowable moisture from contacting both the insulation and the metal panel. panel length per slope that will provide adequate drainage. For FABRAL’s translucent panels are intended for siding applica- longer slopes and lower roof pitches, contact FABRAL for other tions only. In all situations, foot traffic should be avoided on trans- suitable profiles. lucent panels. Translucent panels used in roofing applications will break down in a short time and cause staining and premature Bending and Bowing corrosion of the metal panels below. If used on roofs, apply butyl Aluminum and Steel roofing and siding sheets are rollformed caulking to separate the fiberglass panels from the metal. Trans- from hardened, tempered metal for maximum strength. If a sheet lucent panels should be cleaned and sealed regularly, as recom- must be bent, a gentle 90-degree bend is the maximum recom- mended by the translucent panel manufacturer. mended. Metal should not be re-bent once it has been formed, nor should it be folded back on itself. When a metal roofing sheet Purlins, Girts and Roof Deck must be installed on a curved roof, screws should be installed at The substructure to which the metal panels are fastened must every overlapping rib at the sheet ends to resist the natural ten- be properly spaced and sufficiently thick to provide a roof or wall dency of the metal to spring back. The standard fastening pattern system able to meet required design loads. is permitted over the rest of the sheet. When installing the metal A 2ʺ nominal lumber thickness or 1ʺ nominal thickness are panels shown in this booklet over a curved arch, the minimum both acceptable purlins. If snow guards are to be installed in the radius of the arch is 18’ for aluminum panels and 24’ for steel pan- future, a 2 x 8 purlin can be installed in the area for snow guard els. Use sealant tape or butyl caulking at all sidelaps and endlaps. installation. Call engineering for locations of 2 x 8 purlins. When Additional care and fasteners must be provided when securing using purlins, FABRAL recommends a maximum spacing of 24ʺ the top and bottom purlins on an arched rafter building to pre- on-center (note that 5V requires solid decking). Pullout values de- vent the curved panels from pulling the purlins loose from the raf- crease if the fasteners protrude completely through the purlins. ters. Ring-shank pole barn nails, heavy wood screws, lag screws, Kiln-dried softwood is recommended for purlins or decking (pine, or bolts are often used for attaching these purlins. fir, hemlock, and spruce). Hardwoods are difficult to fasten into without splitting and contain tannic acids that are corrosive to Siding metal panels. Green (non-kiln-dried) lumber may warp, twist, and Siding should be installed using the standard fastening and shrink as the wood seasons fully, causing waviness in the panels as overlap patterns to ensure optimum performance. For strong, well as loosening and leaking of the fasteners. neat corners use hemmed corner flashings. DO NOT RUN SID- Solid decking is highly recommended for all residential appli- ING SHEETS ALL THE WAY TO THE GROUND. INSTEAD, PRO- cations. When using solid decking or sheathing, always use 30-lb VIDE A PROTECTIVE BASE OF CONCRETE, MASONRY, TREAT- felt or underlayment and plan on using closer fastener spacing ED WOOD, OR SIMILAR MATERIAL AND TERMINATE THE and larger diameter #14 screws. (Refer to the tables on page SIDING SHEETS 6ʺ ABOVE GRADE. 31). If siding sheets are installed horizontally, use sealant tape or On re-roofing projects where the condition of the old decking butyl caulking at the vertical laps to ensure weather-tight joints. is in question, or where existing shingles will be left in place, new Install panels from the bottom up so that water is directed away from, and not into, the lap joints. Fastening guidelines for compliance with all safety requirements. FABRAL can supply either screws or nails for fastening into Do Not walk on panels until all the fasteners are installed. dimension lumber. Always use screws with solid sheathing. Metal roofing panels are slippery when wet, dusty, frosty, or oily Screws for use with steel panels are galvanized and then coated -- Do Not attempt to walk on a metal roof under these conditions. with an organic polymer for optimum corrosion resistance. For Wear soft-soled shoes to improve traction and to minimize dam- best results with aluminum panels, use #300 series stainless steel age to the paint finish. Always be aware of your position on the screws. roof relative to any roof openings, roof edges, co-workers, and penetrations. Installing metal panels or flashings on a windy day can be dangerous and should be avoided if possible.
Correct Under-Driven Over-Driven Cutting Aluminum Panels Wood screws with combination metal and neoprene washers To make a cut parallel to the ribs, score the panel deep- should be installed in the flat area of the panel adjacent to the ly with a sharp utility knife and bend back-and-forth along the ribs, and tightened such that the washer is compressed as illus- score, breaking the metal off cleanly. For cuts across the ribs, use trated above. This will ensure a lasting, leak-proof seal. REMOVE straight-cut snips, electric or pneumatic shears, a portable profile ANY METAL FILINGS CREATED BY THE DRILLING ACTION OF shear, or an electric nibbler. Some installers prefer using a circular THE SCREWS OR PRE-DRILLING OF THE HOLES TO AVOID saw with a metal cutting blade (a fine-tooth hardwood blade, or a RUST STAINING ON THE PANEL SURFACE. Refer to the fasten- standard combination blade reversed in the saw works also). Light ing schedules in this booklet for the correct fastener locations. oil or soap on the blade will make cutting easier. Panels adhered with CondenStop Cutting and Drilling Steel Panels FULL LENGTH PANELS FROM EAVE TO RIDGE ARE REC- Steel panels may be cut with metal snips, electric or pneu- OMMENDED, EAVE OVERHANGS, VALLEYS AND ANY OTHER matic shears, a portable profile shear, or an electric nibbler. Some EDGES EXPOSED TO THE WEATHER SHOULD BE PAINTED installers prefer using a circular saw to cut metal panels. Do Not TO SEAL MICROFIBERS FROM ABSORBING MOISTURE FROM use self-consuming abrasive blades because of the following: 1. THE OUTSIDE. WET STACK STORAGE STILL APPLIES TO PAN- Abrasive blades burn the paint and galvanizing at the cut edge, ELS WITH CONDENSTOP APPLIED. PLEASE STORE PROPERLY leaving edges that are jagged and unsightly and rust more quickly BY COVERING AND TILTING ONE END. IT’S ALWAYS BEST IF 2. Abrasive blades produce hot metal filings that embed in the THEY CAN BE STORED INSIDE IF NOT BEING IMMEDIATELY paint and cause rust marks on the face of the panel. If saw cutting INSTALLED. cannot be avoided, select a carbide-tipped blade specially de- signed for cutting light-gage ferrous metal panels. These blades Flashing and Trim are now available at many home centers and lumber yards. 1. All Always begin flashing installation from the bottom and work saw cut panels must be turned face down and cut in a location up, so that upper flashings are lapped on top of lower flashings. down-wind and well away from the building and other panels to This will prevent moisture from leaking under the flashings and avoid embedment of metal filings on other panels 2. All saw cut into the structure. Endlap flashings a minimum of ʺ6 and seal the panels must be thoroughly wiped to ensure the removal of all lap joints with sealant. Extend flashings 4-6ʺ beyond the building, metal filings. Pre-drilling wall panels gives uniform alignment of cut along the bend lines, apply sealant, and fold the side flaps in screw rows. BE SURE TO REMOVE ANY FILINGS ONCE PANELS and the top flaps down to cap off the ends. Secure with pop-rivets ARE INSTALLED TO AVOID RUST MARKS FROM THE FILINGS. or stitch screws. Some roof conditions, such as valleys, may require a longer Building Maintenance endlap and/or a larger flashing to properly drain moisture from A metal roof should be inspected annually and cleaned as the roof. Factors that influence flashing size, shape, and endlap necessary to maintain its beauty and performance. Any debris requirements include roof pitch, roof geometry, slope length, and or residue, including leaves, twigs, and dust should be cleaned climatic factors (such as heavy snowfall or rainfall). off promptly to prevent moisture entrapment against the metal, Whenever possible, begin trim installation at the downwind which may lead to finish deterioration or premature corrosion. end of the roof, farthest away from the source of prevailing winds, Flashings may need to be re-sealed periodically in order to main- to allow flashing laps to face away from wind-driven rain. Refer to tain optimum weathertightness. the details in this book for the proper location of fasteners and sealants. Proper Storage The flashings and trims shown in this book are standard parts. Store metal panels indoors when possible; if outdoors, cover Custom trims are available to meet your specific design needs. If and elevate. Elevate one side higher for water drainage. Never you need a special trim, please furnish a drawing of the desired cover in plastic; us a tarp that can breath. Allow for air circula- shape, including dimensions and angles, to your Fabral dealer to tion. If a bundle gets wet, break bands and separate sheets; allow obtain pricing and availability. sheets to dry completely and only restack if completely dry. Prod- Refer to the SMACNA Architectural Sheet Metal Manual for uct should be stored for a maximum of 2-4 weeks before being additional information about detailing and installing flashings. installed. Safety Spray Foam Insulation Always work safely when installing metal products and use When insulating metal with spray foam insulation, the first extreme caution on the roof at all times. Wear gloves and safety application layer should be getting the insulation behind all fram- glasses to reduce the risk of injury, and use hearing protection ing members. When completing the insulation, ensure the spray when operating power tools. Always be sure that ladders are foam is installed in 2ʺ thick layers (maximum) until desired thick- safely positioned and properly secured. Safety harnesses or other ness is achieved. special equipment may be required; be sure to Consult OSHA STEEL PANELS Grandrib 3®
3737 3/4" 3/4" Formed Widt Widthh 36"36" Coverage 9"
3/4"3/4"
NAIL PATTERNS NAIL S S SCREWPATTERN PATTERN PATTERNSCREW SCREW S NAIL PATTERNS
IntermediateSiding Siding All All Roofand and PurlinsPurlins Purlins andRoof Roof All SidingIntermediate Intermediate All SupportsSupports All
Eaves and EndlapsPurlins Purlins Roof Roof - - - Roof PurlinsEndlaps Endlaps and and Eaves Eaves
80 screws per square or 1 pound of nails per square See page 11 for a load table
TrustiRib™ NAIL PATTERNSPATTERNS NAIL
All SupportsSupports All
S S SCREWPATTERN PATTERN PATTERNSCREW SCREW S
37 3/4"37 Formed 3/4" Formed WidthWidth 36" Coverage36" Coverage IntermediateSiding Siding All All Roofand and PurlinsPurlins Purlins andRoof Roof All Siding Intermediate Intermediate 9"9"
3/4"3/4" Eaves and EndlapsPurlins Purlins Roof Roof - - Roof PurlinsEndlaps Endlaps and and Eaves Eaves
Not all profiles are available in all areas. Please contact Fabral for availability 6 Fabral.com STEEL PANELS
NAIL PATTERN Mighti-Rib®
SCREW PATTERN
ROOFING - EAVES, RIDGES AND ENDLAPS
39" Formed Width 36" Coverage Purlin ROOFING - INTERMEDIATE SUPPORTS 12" Bearing Leg SIDING - ALL SUPPORTS 1 1/4" Please see Mighti-Rib specific trims on page 20 5V Crimp NAIL PATTERN USE ON SOLID DECKING ROOFING - EAVES, RIDGES, AND ENDLAPS
ROOFING - INTERMEDIATE SUPPORTS
SCREW PATTERN 26"26" Formed Formed WidtWidthh 24"24" Coverage Coverage 1/2" 12"12"
1" 1"1" 1/2"1/2" ROOFING - EAVES, RIDGES, AND ENDLAPS
ROOFING - INTERMEDIATE SUPPORTS SIDING - ALL SUPPORTS ProClad Sidelap Detail
SCREW PATTERNS
Intermediate Roof Purlins and All Siding 36" Coverage 9"
5/8" Eaves and Endlaps - Roof Purlins 1 1/4ʺ Corrugated SCREW PATTERN NAIL PATTERN
ROOFING - EAVES, RIDGES, AND ENDLAPS ROOFING - EAVES, RIDGES, AND ENDLAPS
26" Formed Width ROOFING - INTERMEDIATE SUPPORTS ROOFING - INTERMEDIATE SUPPORTS 24" Coverage SIDING - ALL SUPPORTS 1 1/4" 1/4" SIDING - ALL SUPPORTS
2 1/2ʺ Corrugated SCREW PATTERN NAIL PATTERN
ROOFING - EAVES, RIDGES, AND ENDLAPS ROOFING - EAVES, RIDGES, AND ENDLAPS ROOFING - INTERMEDIATE SUPPORTS ROOFING - INTERMEDIATE SUPPORTS 26" Formed Width Coverage Varies* SIDING - ALL SUPPORTS SIDING - ALL SUPPORTS 2 2/3" Note: Roofing panels require side caps cover two corrugations.
1/2" * Wall application- 24ʺ coverage with 1 rib overlap Roof application- 21 1/3" coverage with 2 rib overlap Not all profiles are available in all areas. Please contact Fabral for availability 7 STEEL PANELS
Prime Rib®
38" Formed Width 36" Coverage 1" 1" 3"
1/2"
Grandbeam®
1 424" Formed Width 36" Coverage 9" 9 4" 7 1 4 " " 2" 16 3 8 100° 18"
134° Note: Grandbeam has panel specific flashingsavailable 134°
StrongClad®
36" 5/8" 9"
Not all profiles are available in all areas. Please contact Fabral for availability 8 Fabral.com ALUMINUM PANELS Grandrib 3® Recommended as a Liner Panel only
ROOFING - EAVES, RIDGES, AND ENDLAPS
ROOFING - INTERMEDIATE SUPPORTS SIDING - ALL SUPPORTS
37 3/4"37 Formed 3/4" Formed WidthWidth 36" Coverage36" Coverage 9"9"
3/4"3/4" Strongrib® .018 Aluminum, Plain and Painted White SCREW PATTERN
BUTYL SEALANT Correct Strongrib LOCATION (OPTIONAL Sidelap FIELD APPLIED) INTERMEDIATE ROOF PURLINS AND ALL SIDING
PURLIN BEARING LEG EAVE AND ENDLAPS - ROOF PURLINS
2 1/2" 3/4" 9" 36" Coverage (37 3/4" Formed Width)
Fabrib®
ROOFING - EAVES, RIDGES, AND ENDLAPS
ROOFING - INTERMEDIATE SUPPORTS 51 3/16" Overall SIDING - ALL SUPPORTS 48" Coverage 2 2/3" 3/4"
AluTwin Other widths available 2 1/2ʺ Corrugated
50 1/4" Overall Formed Width Varies Coverage Varies 48" Coverage 8" 2 2/3"
7/16" 1/2"
ROOFING - EAVES, RIDGES, AND ENDLAPS ROOFING - EAVES, RIDGES, AND ENDLAPS
ROOFING - INTERMEDIATE SUPPORTS ROOFING - INTERMEDIATE SUPPORTS SIDING - ALL SUPPORTS SIDING - ALL SUPPORTS
Not all profiles are available in all areas. Please contact Fabral for availability Lengths greater than 16’ on aluminum panels are not recommended due to expansion and contraction. 9 ESTIMATING & ROOF TYPES
Estimating Metal Roofing, Siding & Flashings Panel lengths are to be determined by the truss top chord or actual field measurements. Remem- ber to add for overhangs at the eaves; subtract for a gap at the ridge. Siding should be kept up away from the ground with a skirt board.
Number of Panels The coverage of the panel being used will de- termine the number of panels at a length (i.e., 3' coverage panel on a 30 ft. long building would Gambrel Roof require 10 panels on each side of the ridge or 20 panels at the particular length).
Horizontal Measurement to a Roof Divide the building width in half, then multiply by the slope factor (i.e., 40' wide building with 4/12 slope. 40 divided by 2 equals 20' times 1.054 equals 21'-1" in slope dimension). Allow for 1/2" to 1" gap at peak and 1" to 2" eave overhang.
Roof Pitch Slope Factor 3/12 1.031 4/12 1.054 5/12 1.083 6/12 1.120 8/12 1.202 Transition Roof 10/12 1.302 12/12 1.414
Flashing Conditions Roof - Eave, Ridge, Gable, Sidewall, Endwall, Valley, Hip, Transition, Gambrel, Soffits Siding - Base Perimeter, Corners, Inside Corners, Man Doors, Windows, Sliding Doors, Overhead Doors Please contact Fabral’s Engineering Department for all your estimating & specification needs.
800.477.2741 Hip Roof 717.735.1257 Fax 10 Fabral.com ESTIMATING & ROOF TYPES LOAD TABLES & TESTING
The Above Loads and fastener quantities are based on the standard fasening schedule shown on page 6 of this book, with the fastener having an embedment depth of 1” into the solid wood or penetrating the plywood or OSB. Contact FABRAL for additional design information on our products.
UL RATINGS UL790 Class A Fire Rating applies to all Steel panels 29 ga and thicker and all Aluminum panels .032ʺ and thicker.
UL2218 Class 4 Hail Impact Rating applies to all Steel panels 29 ga and thicker and all Aluminum panels .032ʺ and thicker.
11 p. 41 p. Outside Corner p. 26 p. Eave p. 39 p. Sliding Door Cover Track p. 28 p. Sidewall p. 41 p. Inside Corner p. 34 p. Ridge/Peak p. 27 p. Endwall Gable p. 31 p. p. 36 p. J-Channel/ Doors/Windows p. 36 p. Drip Cap p. 35 p. Base Guard POST FRAME BUILDING DETAILS Zee p. 18 p.
12 Fabral.com RIDGE/PEAK CHIMNEY VALLEY ENDWALL PIPE PENETRATION TRANSITION
SIDEWALL SKYLIGHT EAVE GABLE/RAKE
HIP
RESIDENTIAL exposed-fastener panel BUILDING DETAILS 1. Determine the thickness and type of substrate to be used to support the metal roofing. Solid decking is highly recommended for all residential applications (i.e., plywood, OSB).
2. Refer to the Load-Span tables to select the proper fastener and spacing to meet loads on your structure. Nails are NOT recommended for residential applications.
3. Consult local building codes and restrictions to determine acceptable methods of construction for residential applications in your area.
4. Solid decking with 30# felt or synthetic underlayment for residential applications is recommended. Ice & water shield or similar self-adhesive membrane is recommended at all valleys, dormers, chimneys, transitions, skylights and other critical areas.
5. When re-roofing with metal panels over an existing shingle roof, metal panels may be installed directly over shingles with underlayment, or 2x4 purlins or 1x4 furring strips.
6. Zip board sheathing, which has a “built in” vapor barrier, is an acceptable substrate and vapor barrier.
7. Request Fabral’s technical bulletins #720 and #721 for more details on residential roofing.
13 POST FRAME FLASHING DETAILS ENDLAP & RAIN CARRYING TABLES ALUMINUM (All runs or steel 3+runs) ROOF PANEL 1. Apply 3/32ʺ x 1/2ʺ butyl endlap sealant on bottom STEP #1 CONTINUOUS BEAD OF 3/32" x 1/2" panel just below centerline of purlin (see endlap BUTYL SEALANT TAPE E DOWN SLOP diagram for location) on panel #1. 6 1/2" 2" 2. Apply sidelap sealant on panel #1 and connect OVERLAPPING 3 1/2" to endlap sealant. FROM PURLIN EDGE (2 runs) 3. Place panel #2 so it overlaps panel #1, 12ʺ STEEL 10" To Sealant FASTENERS @ STEP #2 ENDLAP PATTERN as shown. Install screws per endlap fastening ROOF PANEL pattern. SLOPE 4. Apply sidelap sealant on panel #2 to connect to DOWN 6 1/2" sidelap sealant of panel #1. 2" PURLIN OVERLAPPING 3 1/2" 5. Place panel #3 over sidelap of #1 and #2. FROM PURLIN EDGE 12" Total Lap 6. Apply endlap sealant on panel #3. 7. Apply sidelap sealant on panel #3 and connect PREVAILING WI PREVAILING WI with endlap sealant. 8. Place panel #4 over endlap of panel #3. Install screws per endlap pattern. ENDLAP TAPE ALIGN ND ENDLAP TAPE ALIGN ND 9. Repeat sequence for entire roof. WITH PURLIN EDGE WITH PURLIN EDGE
INSTALLATION SEQUENCE INSTALLATION SEQUENCE FOR STRONGRIB, GRANDRIB 3, FOR STRONGRIB, GRANDRIB 3, 5V CRIMP, ALU-TWIN 4 5V CRIMP, ALU-TWIN 4 2 ENDLAP TAPE 2 ENDLAP TAPE SIDELAP TAPE THIS EDGE SIDELAP TAPE THIS EDGE THIS EDGE THIS EDGE 5 5 5 5 SIDELAP TAPE 3 SIDELAP TAPE 3 3 THIS EDGE 3 THIS EDGE 4 4 1 1 2 2 1 1 EAVE EAVE OVERHANG OVERHANG 1" TO 2" WHEN INSTALLING 2 1/2" OR 1 1/4" 1" TO 2" WHEN INSTALLING 2 1/2" OR 1 1/4" CORRUGATED ROOFING USE ) CORRUGATED ROOFING USE SKIRT BOARD OF T INSTALLATION SEQUENCE AS SHOWN T) SKIRT BOARD OF INSTALLATION SEQUENCE AS SHOWN TREATED LUMBER OR FEE TREATED LUMBER OR FEE " (IN " (IN FOUNDATION OF BLOCK "L "L START EN FOUNDATION OF BLOCK START EN 12" TO 18" FROM 12" TO 18" FROM GROUND LEVEL GROUND LEVEL D D
ALLOWABLE PANEL LENGTHS (ft.) ALONG THE SLOPE FOR 4" RAINFALL PER HOUR Roof Slope Panel Name Minimum Slope 2 1/2:12 3:12 3 1/2:12 4:12 5:12 6:12 Grandrib 3 2 1/2:12 58 61 64 67 73 78
Prime Rib 2 1/2:12 39 41 43 45 49 53
5V 2 1/2:12 43 45 47 49 54 58
2 1/2" Corrugated 2 1/2:12 28 29 31 32 35 38
1 1/4" Corrugated 2 1/2:12 16 16 17 18 20 21 Alutwin 2 1/2:12 37 39 41 43 46 50
Fabrib 2 1/2:12 32 34 36 38 41 44
Notes For Rain-Carrying Tables
1. All values based on a 1-hour duration storm of 4"/hr. intensity. 2. Values represent the point at which the panel ribs will flood. 3. Size and frequency of penetrations can greatly reduce the amount of water removed from a roof. 4. All panel endlaps must be caulked. 5. When weather-tightness is crtical, use sealant tape in all sidelaps. 14 Fabral.com STANDARD POST FRAME FLASHINGS & TRIMS All flashing is 10' 6ʺ in length & available in steel & aluminum, unless otherwise noted. Please contact Fabral for specifics on the trim available in your area.
AJ2 Jamb Trim
AJ3 AJ4 J Channel Jamb Trim
AJ6 Jamb Trim
AJ5 RJ8 Jamb Trim J Channel
RJ9 F-J Trim
PJFB #45 Liner Channel One Piece Door Trim F-J Trim F-J 10 Trim Midwest Only 15 POST FRAME FLASHINGS & TRIMS
AG4 AC1 Gable Longer Lengths Corner Longer Lengths Available AG1 Available Gable/Rake
AC3 Corner Longer Lengths Available
AC2 AC4 Inside Corner Corner Longer Lengths Available
1 1/16”
RG1 WG1 Residential Residential AH2 Gable Gable Door Track Cover Longer Lengths Longer Lengths Available Available
AH4 AH5 AH3 Door Track Door Track Double Door Cover Cover Track Cover
16 Fabral.com POST FRAME FLASHINGS & TRIMS
AH6 Door Track AR3 AR3 w/ Versavent RX-10 Cover Ridge Cap Ridge Cap
SB Snow Break (Solid Deck)
RR1 CP1 Universal Monoslope SB1 2 1/8” Snow Break Ridge/Hip Ridge 1 1/2” Flash (2x4 Purlins)
3/4” 1 1/2” 3/4”
AT1 Transition Flash CE1 Denver Eave AT2 Gambrel Flash
ASW1 AEWN4 Sidewall/Endwall Notched Flash Endwall Flash Available in 40 1/2ʺ length only
AGRN4 Notched Gambrel Flash Available in 40 1/2ʺ length only Notched 17 POST FRAME FLASHINGS & TRIMS *Other sizes are available upon request
AL6 2 3/16” AL7 AL2, 3, 4, 5 Angle Flashing Angle Flashing Angle Flashing Longer Lengths Available
AL9 AL10 AL8 Angle Flashing Angle Flashing Angle Flashing
ABG1 203 Box Base Base AZ2 Guard Zee
AB3 AB1 Soffit Box Soffit Box
AD1 Drip Cap
AB2 AB4 7 1/2" Soffit Box Soffit Box
7 1/4" 2 1/2"
RV1 Valley Flash
AE1 Eave Flash
RV2 RE1 W-Valley Flash Residential Eave 18 Fabral.com STANDARD RESIDENTIAL exposed-fastener panel FLASHINGS & TRIMS
All flashing is 10' 6ʺ in length & available in steel & aluminum, unless otherwise noted. Please contact Fabral for specifics on the trim available in your area.
1 1/16”
RG1 AG4 WG1 Residential Gable Residential Gable Gable
AR3 Ridge Cap RV1 CE1 Valley Flash Denver Eave
RR1 Universal Ridge/Hip RV2 Flash W-Valley Flash RE1 Residential Eave AT1 Transition Flash
ASW1 Sidewall/ Endwall Flash CP1 Monoslope AT2 Ridge Gambrel Flash
19 POST FRAME FLASHINGS & TRIMS STANDARD MIGHTI-RIB® FLASHINGS & TRIMS
All Mighti-Rib specific flashing is 10' 6" in length & available in steel, unless otherwise noted. Please contact Fabral for specifics on the trim available in your area.
FH1 Head/Sill Flashing
FE2 Eave Flashing FR4 Ridge Cap
FT1 5" Endwall/
1 11/16" Transition Flash
5" 5/8"
1 3/16" FC4 Inside Corner FC3 Flash Gable/Outside Corner Flash
FZ4 1 3/8" Zee Flash
FJ3 J Channel 1 3/8ʺ Flashing Modified PJFB Trim Modified F-J Trim
20 Fabral.com GENERAL NOTES
21 SYSTEM COMPONENTS SNOW GUARDS
Exposed Fastener MINI CLSM CLSR #640 #20 SM Panel Grandrib 3® X X X Mighti-Rib® X X X TrustiRib™ X X X 5V Crimp X X X X X 2 1/2" Corrugated X ProClad X X X
MINI Clear Snow Guard CL Snow Guard • Available in premium polycarbonate plastic • Available in premium polycarbonate plastic with UV stabilizers with UV stabilizers • Provides maximum protection at a moderate • Unique vent rib systems allows for adhesive out price point gassing • Two-to-one base-to-blade ratio • Three-to-one base-to-blade ratio adds signifi- • 4.5 sq.in. and gusseted blade snow pocket cantly to strength • Typically installed by adhering to and mechani- cally fastened to the roofing panel
Snow Boss Snow Guards (#640) SM Snow Guard • “Traditional Shape” solid cast aluminum • Available in cast aluminum • Applied to the mid-panel on all standing, bat- • Typically installed by adhering to and mechani- ten and flat seam roofs cally fastened to the roofing panel • Typically installed by adhering to and mechani- • Very effective where there are no suitable cally fastened to the roofing panel seams • Low profile protection, ideal for 1" x 2" purlins • Non-Stock item, inquire for lead time • Non-Stock item, inquire for lead time
22 Fabral.com SYSTEM COMPONENTS
FASTENERS For more information, review Fabral’s installation manuals. SYSTEM COMPONENTS #10 WoodTite High Low #14-10 WoodTite • Use with dimensional lumber • Use to fasten metal to plywood or OSB • Available in 1ʺ, 1 1/2ʺ, 2ʺ, 2 1/2ʺ and 3ʺ • Use for trim attachment • 1/4ʺ hex head, EPDM/metal washer • Available in 1ʺ, 1 1/2ʺ, and 2ʺ • Oxyseal Long-Life Coating • 5/16ʺ hex head, EPDM/metal washer • Plain or Painted • Oxyseal Long-Life Coating • 250/bag • Plain or Painted • 250/bag
#10-16 302 Series Stainless Steel #10-14 410 Stainless Steel • Use for high corrosive environments • Use with 26 gauge or thinner to avoid pre-drilling • Use with ALUMINUM panels • NOT as corrosive resistant as the 300 Series • Available in 1ʺ, 1 1/2ʺ, and 2ʺ • Steel is harder than 300 Series • 1/4ʺ hex head, EPDM/metal washer • Available in 1ʺ, 1 1/2ʺ, and 2ʺ • Use with treated lumber • 1/4ʺ hex head, EPDM/metal washer • Plain or Painted • Use with steel panels installed on treated lumber • 250/bag • Plain or Painted • 250/bag
#10-14 Ultimate WoodTite #12 x 3/4ʺ Stitch Screw • Use with ALL panels • Used for attachment of trim to top of seam for screw • Available in 1ʺ, 1 1/2ʺ, 2ʺ, 2 1/2ʺ and 3ʺ flange panels • 1/4ʺ case zinc hex head • Use with STEEL panels • Hex head & washer all one piece • Used to stitch sidelaps for exposed fastener panels • Plain • Used for miscellaneous metal to metal attachments • 250/bag • 1/4ʺ hex head, EPDM/metal washer • Plain or Painted • 250/bag UNDERLAYMENT
30-Year Peel & Stick 50-Year Synthetic PRODUCT SPECS: PRODUCT SPECS: • Watertight Self-Sealing Underlayment • Installation requires mechanical fasteners • Asphalt-to-Asphalt Lap System • Roll Size: 4' W x 250' L • Roll Size: 3' W x 72' L • Minimum Thickness: .75mm • Minimum Thickness: 1.1mm • Square Ft Per Roll: 1,000 • Square Ft Per Roll: 200 • 36 rolls per pallet
CONDENSTOP® Stop condensation with Fabral factory applied CondenStop. CondenStop saves time and money with reduced labor costs and installation time versus other condensation barriers. Easily and effectively prevent condensation and the problems caused by condensation by installing Fabral panels featuring CondenStop. • Protects assets and investments from moisture • Light gray color enhances the indoor look of an • Can be used in place of traditional vapor retarders open framing structure roof • Adds to interior corrosion protection • Available for Grandrib 3 painted panel offerings
23 ACCESSORIES VENTING & CLOSURES
Ridge Cap Vent Specifications: LP2 Closure Specifications: • Venting factory applied to the ridge cap • Available for Grandrib 3, Mighti-Rib, • Save up to half of your installation time Horizon S, and Climaguard profiles • Non-profile specific material • LP2 Clousure Specifications • Clean, dust free installation • Lower, custom-fit profile Virtually NO WASTED material • Moisture and pest barrier • 1 1/2" x 3ʺ material provides 17 sq. • Non-obtrusive appearance inches/lineal foot free area at the ridge • Reduces utility costs • One-person installation Available attached to ridge cap as RX-10 version and as X-10 version for field installation; not pre-applied to ridge cap
Profile Fit Vent- Roll RV35 and RV100 Specifications: Specifications: • Available for Grandrib 3 and 1 1/2" SSR • 10' long metal ridge vent profiles • Variety of colors available • 10.66 sq. in. per lineal ft. of ridge (5.33 / side)
TRANSLUCENT PANELS
Polycarbonate: • Grandrib 3- Clear & White - 8', 10', 12' Mighti-Rib - Clear & White - 12'
24 Fabral.com ACCESSORIES PIPE BOOTS
EPDM Specifications: Pipe Sizes: • Colors: Gray and Black Base Diameter Item No. min max • Up to 2500 F 7 3/4" 3 1/4" 5" 10 3/4" 5 4 1/4" 7 1/2" 16 1/2" 8 7" 13" Silicon Specifications: • Color: Orange • Up to 4500 F • Ranging for pipe sizes from 1" to 13" • Larger sizes available upon request *Retrofit boots also available, sizes may vary FLAT SHEETS Product Specifications: • Used for field forming crickets around • Full width (40 13/16" x 10' 6") chimney, skylights, penetrations, and • Grade 33 steel for better hemming, special flashing as necessary forming and flexibility for field forming • 29 gauge painted and plain galvanized
BACKER ROD Product Specifications: • Reduces the risk of oil canning • Black foam with 5/8" diameter • Available in individual boxes (two rolls at 775' each) • Available in Midwest only SEALANT & SEALER STRIP Sealant Specifications: Sealant Tape Specifications: • Waterproof sealant to fill gaps up to 1" • 3/16" x 1/4" x 40' (side-lap) • UV-resistant • 3/32" x 1/2" x 50' (endlap) • Permanent flexibility - won’t crack • 1/8" x 2" x 30' • Standard color: gray (stocked) • Up to 50 additional color options Asphalt Impregnated Sealer Strip (non stocked) Specifications: • Use at valleys and hips • 1" x 1" x 19' 6.8" long
25 POST FRAME TRIM DETAILS
INSIDE CLOSURE
FASTENER PER STANDARD BUTYL SEALANT TAPE TOP EAVE PATTERN & BOTTOM OF CLOSURE
ROOF PANEL OUTSIDE CLOSURE (OPTIONAL) FLASH CE-1 BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE FASTENER @ EVERY MAJOR RIB
SIDING PANEL
ROOF PURLIN
POST EAVE ROOF TRUSS TOP PLATE
INSIDE CLOSURE
BUTYL SEALANT TAPE TOP 3. EAVE (PAGE 15) & BOTTOM OF CLOSURE
ROOF PANEL EAVE PURLIN
FASTENER PER STANDARD FLASH AB-1, AB-2, EAVE PATTERN AB-3, OR AB-4
FLASH CE-1 FASTENER FASTENER @ 24" O.C. MAX. OUTSIDE CLOSURE (OPTIONAL)
SIDING PANEL BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
TOP PLATE BOX EAVE
26 Fabral.com
4. BOX EAVE (PAGE 15) POST FRAME TRIM DETAILS
INSIDE CLOSURE
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
FASTENER PER STANDARD FABRAL ALUMINUM SOFIT EAVE PATTERN
ROOF PANEL
FLASH CE-1 TOP PLATE
FASTENER @ 24" O.C. MAX. F/J TRIM
SIDING PANEL FASTENER
VENTED EAVE
5. VENTED EAVE (PAGE 16) SIDING PANEL
FASTENER PER STANDARD EAVE PATTERN
GIRT INSIDE CLOSURE
2" FASTENER @ EVERY MAIN RIB
FLASH ASW-1
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
PURLIN ROOF PANEL
ENDWALL OUSIDE CLOSURE
12. ENDWALL (PAGE 21) View installation videos at Fabral.com/videos 27 POST FRAME TRIM DETAILS
ENDWALL- NOTCHED SIDING PANEL
FASTENER PER STANDARD EAVE PATTERN
GIRT
INSIDE CLOSURE
2" FASTENER @ EVERY MAIN RIB NOTCHED FLASH AEW-N4 OR AEW-N5 BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
PURLIN ROOF PANEL
OUSIDE CLOSURE
13. ENDWALL - NOTCHED (PAGE 21) SIDEWALL SIDING PANEL FASTENER PER STANDARD EAVE PATTERN
GIRT SEALER STRIP W/ BUTYL SEALANT TAPE
FLASH ASW-1 FIELD BEND AS REQUIRED
2" FASTENER @ 24" O.C. MAX.
BUTYL SEALANT TAPE
ROOF PANEL
PURLIN
SLOPING RAFTER
ROOF PANEL
28 Fabral.com 14. SIDEWALL (PAGE 22) POST FRAME TRIM DETAILS
RIDGE TRIM
DORMER VALLEY OUTSIDE CLOSURE, TAPE SEALANT TOP & BOTTOM
ROOF PANEL
UNIVERSAL CLOSURE, TAPE LOWER VALLEY TRIM SEALANT TOP & BOTTOM
BUTYL TAPE SEALANT
PEEL & STICK
UNDERLAYMENT UPPER VALLEY TRIM
NOTE: ROOF PANEL OMITTED ON LARGER VALLEYS MAY BE REQUIRED OTHER SIDE OF RIDGE FOR CLARITY. FOR LONG ROOF PANEL RUNS OR VALLEY HEAVY SNOW AREAS. CUT ROOF PANEL AS NECESSARY 39. DORMER VALLEYS (PAGE 43)
RV-2 SHOWN
SCREWS EACH SIDE OF MAIN RIB (EAVE / ENDLAP PATTERN)
PEEL & STICK
SEALER STRIP, 1" X 1" X 19'-8" BLOCK CLOSURE, FILL RIB VOIDS
ROOF STRUCTURE, SOLID 2X'S OR PLYWOOD
BUTYL SEALANT TOP & BOTTOM OF SEALER STRIP NOTE: VALLEY FLASH MUST HAVE SOLID SUPPORT
View installation videos at Fabral.com/videos 29 POST FRAME TRIM DETAILS
ROOF PANEL FASTENER PER STANDARD EAVE PATTERN
2" FASTENER @ EVERY MAIN RIB BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
FLASH AT-2 OR AGR-N4 (GRANDRIB 3) INSIDE CLOSURE
OUSIDE CLOSURE
ROOF PANEL PURLIN
BUTYL SEALANT TAPE TOP GAMBREL & BOTTOM OF CLOSURE
NOTE: SPECIFY BOTH ROOF PITCHES WHEN ORDERING AT-2 FLASH. AGRN-4 FOR GRANDRIB 3 AND AGRN-5 FOR STRONGRIB ARE FOR 3/12 TO 15/12 GAMBRELS.
BUTYL SEALANT TAPE TOP & FASTENERS PER STANDARD BOTTOM OF CLOSURE16. GAMBREL (PAGE 23) EAVE PATTERN
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
INSIDE CLOSURE
2" FASTENER @ EVERY MAIN RIB
PURLIN FLASH AT-1
ROOF PANEL
OUSIDE CLOSURE
NOTE: SPECIFY BOTH ROOF PITCHES WHEN ORDERING AT-1. STANDARD IS 9/12 TO 3/12. TRANSITION
30 Fabral.com 17. TRANSITION (PAGE 23) POST FRAME TRIM DETAILS
BOX GABLE ROOF PANEL VERSION 1 FLASH AC-1 OR AC-4
ROOF PURLIN FASTENER @ 24" O.C. MAX. FLASH AB-1, AB-2, AB-3, OR AB-4 BUTYL SEALANT TAPE FASTENER @ EVERY MAJOR RIB
OUTSIDE CLOSURE (OPTIONAL) BUTYL SEALANT TAPE TOP & BOTTOM OF SEALER STRIP
END RAFTER
FASTENER SIDING PANEL 24" O.C. MAX.
BUTYL SEALANT TAPE
BOX GABLE 1. BOX GABLE (PAGE X) VERSION 2 ROOF PANEL
FLASH AG-1 ROOF PURLIN
FASTENER @ FLASH AB-1, AB-2, 24" O.C. MAX. AB-3, OR AB-4
BUTYL SEALANT TAPE FASTENER @ EVERY MAJOR RIB
OUTSIDE CLOSURE (OPTIONAL)
FASTENER @ BUTYL SEALANT TAPE TOP 24" O.C. MAX. & BOTTOM OF SEALER STRIP
END RAFTER BUTYL SEALANT TAPE
SIDING PANEL
View installation videos at Fabral.com/videos 31 2. BOX GABLE (PAGE 14 & 18) POST FRAME TRIM DETAILS
GABLE ROOF PANEL VERSION 1 FLASH AG-4
FASTENER @ 24" O.C. MAX.
BUTYL SEALANT TAPE PURLIN
FASTENER @ EVERY MAJOR RIB
SIDING PANEL
END RAFTER
OPTIONAL BUTYL SEALANT TAPE TOP AND BOTTOM OF SEALER STRIP
OUTSIDE CLOSURE (OPTIONAL)
GABLE 10. GABLE (PAGE 19) ROOF PANEL VERSION 2 FLASH AC-1 OR AC-4
FASTENER @ 24" O.C. MAX.
BUTYL SEALANT TAPE PURLIN
FASTENER @ EVERY MAJOR RIB
SIDING PANEL
END RAFTER
OPTIONAL BUTYL SEALANT TAPE TOP AND BOTTOM OF CLOSURE
OUTSIDE CLOSURE (OPTIONAL)
32 Fabral.com 9. GABLE (PAGE 19) View installation videos at Fabral.com/videos POST FRAME TRIM DETAILS FLYING GABLE DETAIL
OVERHANG ROOF PANELS TO CREATE APPROX. 1" OVERHANG
CE-1
UNDERLAYMENT
BUTYL SEALANT TOP & BOTTOM OF SEALER STRIP
SEALER STRIP (ASPHALT IMPREGNATED)
FASTENER
FASCIA BOARD
2" FASTENER @ 11. FLYINGEVERY MAIN RIB GABLE (PAGE 20)
MONOSLOPE RIDGE CAP
OUSIDE CLOSURE
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
SIDING
UNDERLAYMENT
ROOF STRUCTURE
MONOSLOPE RIDGE SLOPING RAFTER
View installation videos at Fabral.com/videos 33 18. MONOSLOPE RIDGE (PAGE24) POST FRAME TRIM DETAILS NON VENTED RIDGE/HIP
AR-3, RIDGE FLASHING
2" LONG FASTENER @ EVERY MAIN RIB
ROOF PANEL
OUTSIDE CLOSURE (ON HIP ROOFS, USE 1" X 1" X19'-8" SEALER STRIP & RR-1 FLASHING)
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE ROOF PURLIN
CUT 4-BEND RIDGE CAP 6.FOR FINISHEDRIDGE/PEAK END - NON VENTED (PAGE 16)
AR-3, RR-1 RIDGE FLASH VENTED RIDGE
2" LONG FASTENER @ EVERY MAIN RIB
ROOF PANEL
VERSAVENT RX-10
BUTYL SEALANT TAPE
ROOF PURLIN 34 Fabral.com 7. VENTED RIDGE (PAGE 17) POST FRAME TRIM DETAILS ALTERNATE VENTED RIDGE
RR-1 RIDGE FLASH
2-1/2" FASTENER @ EVERY MAIN RIB
CORRUGATED VENT ROOF PANEL FASTENER PER STANDARD PATTERN OPTIONAL J-CHANNEL FOR SUPPORT UNDERLAYMENT ROOF PANEL ROOF STRUCTURE OUTSIDE CLOSURE WITH BUTYL SEALANT TOP AND BOTTOM
BASE GUARD8. ALT. VENTED RIDGE (PAGE 17) SIDING PANEL
STAINLESS STEEL FASTENER PER STANDARD SIDING PATTERN
INSIDE CLOSURE (OPTIONAL)
FLASH ABG-1
BARRIER BETWEEN METAL AND ACQ TREATED LUMBER
TREATED BASE PLANK
FLOOR
GRADE
View installation videos at Fabral.com/videos 35
22. BASE GUARD (PAGE 25) POST FRAME TRIM DETAILS DOOR HEADER
DOOR HEADER
SIDING PANEL
FASTENERS PER FASTENER PATTERN
FLASH AD-1
FLASH AL-2, AL-3, AL-4, AL-5, OR AL-7 DOOR STOP
DOOR
GIRT 31. DOOR HEADER (PAGE 28) SIDING PANEL DOOR JAMB DOOR JAMB VERSION 1 FASTENERS PER FASTENER PATTERN
DOOR STOP
DOOR
FLASH PJFB
FASTENER 36 Fabral.com View installation videos at Fabral.com/videos
23. DOOR JAMBS (PAGE 26) POST FRAME TRIM DETAILS
GIRT
DOOR JAMB SIDING PANEL VERSION 2 FASTENERS PER DOOR JAMB FASTENER PATTERN BUTYL SEALANT TAPE
FLASH AL-2, AL-3, AL-4, AL-5, OR AL-7 DEPENDING ON WIDTH OF JAMB
DOOR STOP
DOOR
FLASH AJ-3
FASTENER
DOOR JAMB GIRT VERSION 3 FASTENERS PER FASTENER PATTERN
SIDING PANEL
BUTYL SEALANT TAPE
24. DOOR JAMBSFASTENER (PAGE 26) DOOR JAMB
FLASH AJ-2
1 X 3 DOOR STOP
DOOR
View installation videos at Fabral.com/videos 37
25. DOOR JAMBS (PAGE 26) POST FRAME TRIM DETAILS OVERHEAD DOOR JAMBS
VERSION 1 VERSION 3
GIRT DOOR JAMB GIRT DOOR JAMB FASTENERS PER FASTENERS PER POST POST FASTENER PATTERN FASTENER PATTERN OVERHEAD DOOR OVERHEAD DOOR SIDING SIDING PANEL PANEL
DOOR JAMB DOOR JAMB
BUTYL SEALANT TAPE FLASH AL-3, AL-4, AL-5, OR AL-7
FASTENER
BUTYL SEALANT TAPE
FASTENER
FLASH AL-5 OR AL-7
1 X 3 GUIDE BUTYL SEALANT TAPE
FLASH AJ-4 FASTENER
1 X 3 GUIDE
FLASH AJ-3
26. OVERHEAD DOOR JAMBS (PAGE 27) 29. OVERHEAD DOOR JAMBS (PAGE 27) VERSION 2 VERSION 4
DOOR JAMB GIRT GIRT DOOR JAMB FASTENERS PER FASTENERS PER FASTENER PATTERN POST FASTENER PATTERN POST
OVERHEAD DOOR SIDING OVERHEAD DOOR SIDING PANEL PANEL DOOR JAMB
DOOR JAMB
FASTENER
1 X 3 GUIDE
FLASH PJFB
BUTYL SEALANT TAPE
FASTENER
1 X 3 GUIDE
FLASH AJ-2
27. OVERHEAD DOOR JAMBS (PAGE 27) 30. OVERHEAD DOOR JAMBS (PAGE 27)
38 Fabral.com View installation videos at Fabral.com/videos POST FRAME TRIM DETAILS
WALL GIRT SIDING PANEL POST
BUTYL SEALANT TAPE
FASTENER
2 X 2 FILLER BLOCK
BUTYL SEALANT TAPE
FASTENER
OPTIONAL AL-3 TRIM
AJ-4 JAMB TRIM
BUTYL SEALANT TAPE
FLASH AL-6
FLASH AJ-3
FASTENER
SIDING PANEL
SLIDING DOOR SLIDING DOOR JAMB
32. SLIDING DOOR JAMB DETAIL (PAGE 28)
SLIDING DOOR HEADER SLIDING DOOR BASE
SIDING PANEL SIDING PANEL ON FASTENERS PER SLIDING DOOR FASTENER PATTERN FASTENERS PER FLASH AH-2, AH-3, AH-4, OR AH-5 DEPENDING ON PARTICULAR MANUFACTURER'S DOOR FASTENER PATTERN TRACK BEING USED SLIDING DOOR GIRT OVERHEAD DOOR TRACK
FLASH AD-1 FASTENERS PER FASTENER PATTERN
TRACK SUPPORT TREATED BASE PLANK
2 X 6 TRACK BOARD FLOOR
SLIDING DOOR GIRT GRADE
SIDING PANEL ON SLIDING DOOR
33. SLIDING DOOR HEADER (PAGE 29)
View installation videos34. at SLIDINGFabral.com/videos DOOR BASE39 (PAGE 29) POST FRAME TRIM DETAILS
WINDOW WINDOW SILL HEADER
WINDOW UNIT
SIDING PANEL
1 X 6, BEVELED FASTENERS PER FASTENER PATTERN
BUTYL SEALANT TAPE FLASH AJ-3
2 X 4
2 X 4
INSIDE CLOSURE (OPTIONAL)
AD1 DRIP CAP
FASTENERS PER WINDOW UNIT FASTENER PATTERN
SIDING PANEL
37. WINDOW HEADER (PAGE 30)
36. WINDOW SILL (PAGE 30) TRANSLUCENT WINDOW JAMB PANEL METAL SIDING OR TRANSLUCENT ROOF PANEL GIRT
SIDING PANEL 2 X 4 2" FASTENER @ EVERY MAIN RIB OR 12" O.C. MAX.
FLASH AZ-2 FASTENER FASTENERS PER OPTIONAL BUTYL FASTENER PATTERN SEALANT TAPE BUTYL SEALANT TAPE
FLASH AJ-3 INSIDE CLOSURE (OPTIONAL) WINDOW UNIT
OUTSIDE CLOSURE (OPTIONAL)
GIRT
BUTYL SEALANT TAPE
METAL SIDING OR TRANSLUCENT ROOF PANEL
38. WINDOW JAMB (PAGE 30)35. TRANSLUCENT ROOF PANEL (PAGE Fabral.com 40 29) POST FRAME TRIM DETAILS
POST
BUTYL SEALANT TAPE
FASTENER @ 24" O.C. MAX.
FLASH AC-2 GIRT
FASTENERS PER SIDING PANEL FASTENER PATTERN
INSIDE CORNER
GIRT VERSION 1 SIDING PANEL BUTYL SEALANT TAPE FASTENERS PER FASTENER21. PATTERN INSIDEPOST CORNER (PAGE 25)
METAL SIDING OR TRANSLUCENT ROOF PANEL
2" FASTENER @ EVERY MAIN RIB OR 12" O.C. MAX. VERSION 2 FLASH AZ-2 GIRT SIDING PANEL FASTENERS PER BUTYL SEALANT FASTENER PATTERN FASTENERS PER TAPE FASTENER PATTERN POST BUTYL SEALANT TAPE
FASTENER @ 24" O.C. MAX. INSIDE CLOSURE (OPTIONAL) FLASH AC-1 OR AC-4
OUTSIDE CLOSURE (OPTIONAL)
GIRT 19. OUTSIDE CORNER (PAGE 24)
BUTYL SEALANT TAPE OUTSIDE CORNERS
METAL SIDING OR FASTENER @ TRANSLUCENT ROOF PANEL 24" O.C. MAX.
FLASH AC-1 OR AC-4 35. TRANSLUCENT ROOF PANEL (PAGE View installation videos at Fabral.com/videos 41 29) 20. OUTSIDE CORNER (PAGE 24) RESIDENTIAL exposed-fastener panel TRIM DETAILS
All residential flashings are formed for a 4/12 pitch unless otherwise requested by the customer.
RESIDENTIAL VENTED EAVE
UNDERLAYMENT
INSIDE CLOSURE
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
FASTENER PER STANDARD FABRAL ALUMINUM SOFFIT EAVE PATTERN
ROOF PANEL
FLASH CE-1 TOP PLATE
FASTENER @ 24" O.C. MAX. F/J TRIM
SIDING PANEL FASTENER
RESIDENTIAL EAVE
44. RES. VENTED EAVE (PAGE 35) ROOF STRUCTURE
UNDERLAYMENT FLASH CE-1
BUTYL TAPE SEALANT ON TOP FASTENER PER STANDARD & BOTTOM OF CLOSURE EAVE PATTERN
FASTENER @ 24" O.C. MAX. INSIDE CLOSURE
42 Fabral.com 45. RES. EAVE (PAGE 35) RESIDENTIAL TRIM DETAILS
RESIDENTIAL ENDWALL
SIDING
2" FASTENER @ EVERY MAIN RIB
FLASH ASW-1
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
UNDERLAYMENT
ROOF STRUCTURE ROOF PANEL
OUTSIDE CLOSURE
RESIDENTIAL SIDEWALL 47. RES. ENDWALL (PAGE 36) SIDING
FLASH ASW-1 FIELD BEND AS REQUIRED
2" FASTENER @ 24" O.C. MAX.
BUTYL SEALANT TAPE
ROOF PANEL
ROOFING FELT AND ICE AND WATERSHIELD FOR ADDED WEATHER TIGHTNESS
ROOFING STRUCTURE
Fabral.com View installation videos at Fabral.com/videos 43 49. RES. SIDEWALL (PAGE 37) RESIDENTIAL TRIM DETAILS RESIDENTIAL VALLEY SCREWS EACH SIDE OF MAIN RIB (EAVEAND BETWEEN / ENDLAP MINOR PATTERN) RIBS
CUT ROOF PANEL AS NECESSARY
RV-2 SHOWN
PEEL & STICK
SEALER STRIP, 1" X 1" X 19'-8" BLOCK CLOSURE, FILL RIB VOIDS
ROOF STRUCTURE, SOLID 2X'S OR PLYWOOD
BUTYL SEALANT TOP & SOLID SUPPORT IS REQUIRED UNDER THE BOTTOM OF SEALER STRIP VALLEY. PEEL & STICK IS RECOMMENDED UNDER LAPPED ROOF PANELS AND VALLEY FLASHING. LINING MUST CONTINUE DOWN TO EAVE LINE. 52. RES. VALLEY (PAGE 42) RIDGE TRIM DORMER VALLEY OUTSIDE CLOSURE, TAPE SEALANT TOP & BOTTOM
ROOF PANEL
UNIVERSAL CLOSURE, TAPE LOWER VALLEY TRIM SEALANT TOP & BOTTOM
BUTYL TAPE SEALANT
PEEL & STICK
UNDERLAYMENT UPPER VALLEY TRIM
NOTE: ROOF PANEL OMITTED ON OTHER SIDE OF RIDGE FOR CLARITY. 44 Fabral.com 39. DORMER VALLEYS (PAGE 43) View installation videos at Fabral.com/videos RESIDENTIAL TRIM DETAILS
RESIDENTIAL GAMBREL ROOF PANEL
FASTENER PER STANDARD EAVE PATTERN
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
2" FASTENER @ EVERY MAIN RIB
UNDERLAYMENT
INSIDE CLOSURE
FLASH AT-2 OR AGR-N4 (GRANDRIB 3)
OUTSIDE CLOSURE ROOF PANEL
ROOF STRUCTURE BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
NOTE: SPECIFY BOTH ROOF PITCHES WHEN ORDERING AT-2 FLASH. AGRN-4 FOR GRANDRIB 3 AND AGRN-5 FOR STRONGRIB ARE FOR 3/12 TO 15/12 GAMBRELS.
48. RES. GAMBREL (PAGE 37) RESIDENTIAL TRANSITION FASTENER PER STANDARD BUTYL SEALANT TAPE TOP EAVE PATTERN & BOTTOM OF CLOSURE
2" FASTENER @ EVERY MAIN RIB
INSIDE CLOSURE ROOF PANEL FLASH AT-1
ROOF STRUCTURE BUTYL SEALANT TAPE TOP OUTSIDE CLOSURE & BOTTOM OF CLOSURE
50. RES. TRANSITION (PAGE 38) View installation videos at Fabral.com/videos 45 RESIDENTIAL TRIM DETAILS
RESIDENTIAL PIPE BOOTS VENTILATION PIPE
(OPTIONAL) SILICONE SEALANT AROUND CUT OF BOOT
PIPE BOOT
BUTYL SEALANT TAPE ROOF PANEL UNDER BSE OF PIPE BOOT
SCREWS SPACED 2" TO 3" MAX AROUND BASE TO SECURE
ROOF STRUCTURE
UNDERLAYMENT
SKYLIGHT SKYLIGHT SECTION51. A-A RES. PIPE BOOTS (PAGE 38) and B-B on following page
46 Fabral.com 59. SKYLIGHT RESIDENTIAL TRIM DETAILS
SKYLIGHT
FLASH ASW-1 FIELD BEND AS REQUIRED
FRAMING
2" FASTENER @ 6" O.C. MAX.
BUTYL SEALANT TAPE
ROOF PANEL
UNDERLAYMENT SKYLIGHT SECTION A-A SECTION A-A ROOF STRUCTURE
SKYLIGHT
53. SKYLIGHT (PAGE 40)SEALANT
FLASHING - REVERSE AL FLASHING
CONTINUOUS SIKAFLEX CAULK @ PERIMETER
2" FASTENER @ 6" O.C. MAX.
BUTYL SEALANT TAPE
UNDERLAYMENT
ROOF STRUCTURE SECTION A-A
ROOF PANEL
54. SKYLIGHT (PAGE 40) SKYLIGHT SECTION B-B SKYLIGHT SECTION B-B SEALANT
2" FASTENER @ EVERY MAIN RIB
ASW-1 FLASHING FIELD MODIFIED TO FIT
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
FRAME
ROOF PANEL
OUTSIDE CLOSURE
UNDERLAYMENT
ROOF STRUCTURE
View55. SKYLIGHT installation (PAGE videos 40) at Fabral.com/videos 47 RESIDENTIAL TRIM DETAILS CHIMNEY DETAILS
BRICK VERSION 1
1 SAW CUT REGLET 2" - 1" DEEP, BLOW OUT DUST & FILL WITH SIKAFLEX SEALANT. SET FLASH & FASTEN WITH COMPATIBLE MASONRY ANCHOR.
FLASH ASW-1 FIELD MODIFY AS REQUIRED
2" FASTENER @ 24" O.C. MAX.
BUTYL SEALANT TAPE
ROOF PANEL
UNDERLAYMENT
ROOF STRUCTURE
BRICK
CONTINUOUS SIKAFLEX 56. CHIMNEY (PAGE VERSION41) 2 CAULK @ PERIMETER
1 SAW CUT REGLET 2" - 1" DEEP, BLOW OUT DUST & FILL WITH SIKAFLEX SEALANT. SET FLASH & FASTEN WITH COMPATIBLE MASONRY ANCHOR.
FLASHING - REVERSE AL FLASHING
2" FASTENER @ 24" O.C. MAX.
BUTYL SEALANT TAPE
ROOF PANEL
UNDERLAYMENT
ROOF STRUCTURE 48 Fabral.com View installation videos at Fabral.com/videos 57. CHIMNEY (PAGE 41) RESIDENTIAL TRIM DETAILS CHIMNEY ENDWALL
BRICK
1 SAW CUT REGLET 2" - 1" DEEP, BLOW OUT DUST & FILL WITH SIKAFLEX SEALANT. SET FLASH & FASTEN WITH COMPATIBLE MASONRY ANCHOR.
2" FASTENER @ EVERY MAIN RIB
FLASH ASW-1 FIELD MODIFIED TO FIT
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
OUTSIDE CLOSURE
ROOF PANEL
UNDERLAYMENT
ROOF STRUCTURE
RESIDENTIAL58. RIDGE/HIP CHIMNEY (PAGE 41)
2" FASTENER @ EVERY MAIN RIB
RIDGE CAP RR-1 OR AR-3
ROOF PANEL
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
OUTSIDE CLOSURE (ON HIP ROOFS USE 1" X 1" X 19'-8" SEALER STRIP AND RR-1 FLASHING)
UNDERLAYMENT
ROOF STRUCTURE
41. RES. RIDGE/HIP (PAGE 34) View installation videos at Fabral.com/videos 49 RESIDENTIAL TRIM DETAILS RESIDENTIAL VENTED RIDGE
2" FASTENER @ EVERY MAIN RIB
RIDGE CAP RR-1 OR AR-3
ROOF PANEL
CORRUGATED VENT
BUTYL SEALANT TAPE TOP & BOTTOM OF CLOSURE
OUTSIDE CLOSURE (ON HIP ROOFS USE 1" X 1" X 19'-8" SEALER STRIP AND RR-1 FLASHING)
UNDERLAYMENT
ROOF STRUCTURE
42. RES. VENTED RIDGE (PAGE 34) RESIDENTIAL GABLE ROOF PANEL
FASTENER
BUTYL TAPE
RG-1, WG-1, OR AG-4
SCREW FASTENER @ 24" O.C. MAX.
ROOF STRUCTURE
UNDERLAYMENT
50 Fabral.com
46. GABLE (PAGE 36) PAINT SYSTEMS & WARRANTIES
Enduracote® is a paint system that takes performance to the next level. Based on cutting edge resin technology, this system offers unbeatable durability and superior long-term performance against the elements.
The Enduracote® PLUS Warranty The Enduracote® Warranty • Lifetime film integrity for walls & roofs for Galvalume® Panels • 30-year against fade & chalk for walls and roofs • Lifetime film integrity for walls & roofs • 15-year edge rust against acid rain • 30-year against fade & chalk for walls and roofs • 25-year non-perforation against acid rain for walls; • 20 year non-perforation warranty 20-years for roof For profiles: Grandrib 3, 1 1/2" SSR, Climaguard, Mighti-Rib, For profiles: Grandrib 3 PLUS Horizon S, Horizon 16, Ultra-Loc, Ultra-Rib
The Enduracote® Warranty OTHER WARRANTIES for Galvanized Panels Polyester Paint Warranty • Lifetime film integrity for walls & roofs • 25-year limited film integrity • 30-year against fade & chalk for walls and roofs • 10-year against fade & chalk • 10-year edge rust against acid rain For profiles: Shelterguard®, 5-Rib For profiles: Grandrib 3, 5V Crimp, ProClad, StrongClad, Prime Rib, Grandbeam Galvalume® Perforation Warranty • 20-year non-perforation warranty for Grandrib 3, TrustiRib™ Warranty Mighti-Rib, Climaguard, Horizon S and 1 1/2" SSR • 40-year film integrity Galvalume is a registered trademark of BIEC International. • 30-year fade and chalk prorated at a subsequent 5% Aluminum Product Guarantee every year beginning at year 10 ROOF PANEL • 30-year corrosion guarantee
FASTENER Product Warranties are available upon request BUTYL TAPE
RG-1, WG-1, OR AG-4 The ENERGY STAR® Program The ENERGY STAR Program promotes highly reflective roof systems that reflect solar energy. SCREW FASTENER These roof systems allow buildings to stay cooler @ 24" O.C. MAX. and, in turn, use less electricity for air conditioning; less electricity means a reduction in power generation and a re- duction of pollutants discharged at power plants. Fabral has attained ENERGY STAR approval for many of its Endur- ® ROOF STRUCTURE acote system colors. Ask for Technical Bulletin #724 titled “ENERGY STAR Approval,” for program details and a list of approved Enduracote® colors. UNDERLAYMENT
All Fabral Enduracote Colors are ENERGY STAR Approved
/ GALVALUME
Please contact your Fabral representative for more information about Fabral warranties and paint systems. 51
46. GABLE (PAGE 36) COMPLETE CONTACT INFORMATION Contact by Phone - Nationwide Plant Locations
Cedar City, UT (800) 432-2725 Marshfield, WI (800) 528-0878
Grapevine, TX (800) 477-9066 Spokane, WA* (800) 456-9124 (800) 477-8028 Gridley, IL (800) 451-3974 St. Joseph, MN (800) 873-3440 Jackson, GA (800) 884-4484 Tifton, GA (800) 749-8144 Lancaster, PA (800) 477-2741
Contact by Email [email protected]
Fabral.com/contact
Live Tech Chat Fabral.com
*Both numbers service Northern California, Oregon, Washington areas
GENERAL NOTES
52 Fabral.com GENERAL NOTES
53 GRANDRIB 3 PLUS, GRANDRIB, TRUSTIRIB ,MIGHTI-RIB, PROCLAD, HORIZON CLIMAGUARD, FABRIB, ENDURACOTE, FABRAL, FABRAL CORE are registered trademarks of Euramax International, Inc. UL is the trademark of UL LLC Galvalume is the trademark of BIEC International Inc. © Fabral 2015 All rights reserved. Fabral.com 98-32-007 - 1/15