Goltermann PLOTS

Total Page:16

File Type:pdf, Size:1020Kb

Goltermann PLOTS 1 NOTES: 1 2 A-10 3 4 19'-0" 24'-0" 16'-0" 8'-5" 4" 15'-0" 3'-8" 7'-0" 5'-0" 5'-0" 7'-0" 3'-8" 12'-0" 4" 7'-6" 7'-6" 6'-0" 6'-0" AMENDMENTS 2 A-10 RAKE RAKE RAKE RAKE CUSTOM CUSTOM CUSTOM CUSTOM A PROJECT TITLE: LOG SIZING FOR ROOF SYSTEM: GOLTERMAN LOG PURLINLOG REFER TO ROOF PLAN PAGE A-8 LOG PURLINLOG LOG HOME LOG COLLAR TIES BOLT LOG RIDGE BEAM LOG THROUGH LOG RAFTER w 14'-0" 14'-0" DESTINATION: GUARD RAIL 4 - 5/8" Ø GRK BOLTS LOG POST FROM TOP BRECKENRIDGE, CO EAGLE PANEL TO CODE 10/12 ROOF PITCH OF LOG WALL TO BOTTOM ROOF FRAMING ASSEMBLY: OF LOG RIDGE BEAM ASPHALT SHINGLE LOG POST BALCONY BITUTHENE MAIN: 2620 sq. ft. STRUCTURAL EAGLE PANELS LOFT: 1630 sq. ft. 3'-0" 6'-0" 6'-8" 6'-8" BALCONY LOG TRUSS B PREPARED FOR: LOG HEADER LOG HEADER OPEN EXTERIOR FRAME WALL ASSEMBLY: D ZERO CLEARANCE EXTERIOR WOOD FINISH TO CLIENTS SPECS; NATURAL GAS TO BUILDING PAPER FIREPLACE. INSTALL 7/16" PLYWOOD OR OSB SHEATHING SUITE #2 TO MANU. SPECS BELOW SUITE #3 2x6 @ 16" oc FRAME WALL L 110 V - TO BE O 110 V - TO BE SD G SD BATT INSULATION V P INTERCONNECTED A INTERCONNECTED I POLY AVB L H CHIMNEY L RIDGE BEAM LOG EACH FLOOR. E EACH FLOOR. INTERIOR FINISH TO CLIENTS SPECS Y OG B L E IP A G H LOG PURLIN M LOG PURLIN LO LOG RIDGE RIDGE LOG BEAM GUARD RAIL LOFT FLOOR ASSEMBLY: L TO CODE O 3/4" FINISH FLOOR TO CLIENT'S SPECS M G A PREPARED BY: E V 1-1/2" GYPCRETE TOPPING B A Y L E L 3/4" PLYWOOD SUBFLOOR 4'-0" L E 4'-6" L L LOG POST TO U/S Y OG 3'-6" 2'-8" B HI 2x8 JOISTS 16"oc VA 2'-8" E RAKE L P G OF LOG RIDGE BEAM A O 6'-8" M O 3/4" CEILING TO CLIENT'S SPECS G L D 6'-8" N H LOG FLOOR JOISTS I LOG RIDGE BEAM P 34'-0" 34'-0" DORMER PURLIN BOLTED DORMER PURLIN BOLTED UNDER MAIN RIDGE BEAM UNDER MAIN RIDGE BEAM 1 8 OPEN LOFT CANADA DIVISION 1 INTERIOR FRAME WALLS T 9 SD . R @ 110 V - TO BE 351 HODGSON ROAD . @ GUARD RAIL 1 1 ALL INTERIOR FRAME WALL TO BE 2x4 WILLIAMS LAKE, BC INTERCONNECTED 7 5 TO CODE " / V2G 3P7 CANADA RAIL & SHELF 8 @ 16" oc UNLESS NOTED OTHERWISE. " EACH FLOOR. PH (250) 392-5577 FAX (250)- 392-5581 2'-6" 2'-4" 2'-6" 6'-8" WIC WIC SHELVES TOLL FREE: 1-877-822-5647 2'-4" 6'-8" 6'-8" 6'-8" SHELVES 2'-8" LOG PURLIN 6'-8" L LOG PURLIN O G U.S. DIVISION V A LOG PURLIN L P.O. BOX 301 5'-0" TUB 2'-8" 6'-8" STORAGE L LINEN KNEE BRACE TO E KNEE BRACE TO PAYSON, ARIZONA Y 5'-0" +/- SUPPORT DUMMY LINEN B SUPPORT DUMMY 85547 - 0301 E HEADROOM PURLIN UNDER A PURLIN UNDER UNITED STATES M PH (928) 472-8073 MAIN ROOF BATH MAIN ROOF FAX (928) 474-8991 9'-2"9'-2" 7'-10" 5'-7" 2'-3" 7'-10"BATH 9'-2" 4'-3" 9'-9" 9'-2" 7'-10" 17'-0" 4'-3" 9'-9" TOLL FREE: 1-877-224-4654 6'-8" +/- DRAWING TITLE: EAGLE PANEL ROOF SYSTEM ROOF WINDOW SEAT HEADROOM C HANDCRAFTED LOG HEADER HANDCRAFTED LOFT FLOOR 6'-0" 3'-6" 3'-0" 3'-6" LOG HEADER 3'-0" 3'-6" TEMP TEMP TEMP PLAN LOG PURLIN LOG 8'-0" LOG PURLINLOG LOG RIDGE BEAM SCALE: 2"x6"@ 16"oc EAGLE PANEL 2"x6"@ 16"oc BEARING WALL ROOF SYSTEM BEARING WALL D DATE: RAKE RAKE RAKE RAKE CUSTOM CUSTOM CUSTOM CUSTOM APRIL 19, 2006 5'-0" 8'-0" 2 A-10 DRAWN BY: D. FITZEL 7'-5" 7'-7" 2'-6" 7'-0" 2'-6" CHECKED BY: 4" 15'-0" 3'-8" 7'-0" 5'-0" 5'-0" 7'-0" 3'-8" 12'-0" 4" PAGE: 19'-0" 24'-0" 16'-0" A - 7 LOFT FLOOR PLAN.
Recommended publications
  • BUILDING CONSTRUCTION NOTES.Pdf
    10/21/2014 BUILDING CONSTRUCTION RIO HONDO TRUCK ACADEMY Why do firefighters need to know about Building Construction???? We must understand Building Construction to help us understand the behavior of buildings under fire conditions. Having a fundamental knowledge of buildings is an essential component of the decisiondecision--makingmaking process in successful fireground operations. We have to realize that newer construction methods are not in harmony with fire suppression operations. According to NFPA 1001: Standard for FireFighter Professional Qualifications Firefighter 1 Level ––BasicBasic Construction of doors, windows, and walls and the operation of doors, windows, and locks ––IndicatorsIndicators of potential collapse or roof failure ––EffectsEffects of construction type and elapsed time under fire conditions on structural integrity 1 10/21/2014 NFPA 1001 Firefighter 2 Level ––DangerousDangerous building conditions created by fire and suppression activities ––IndicatorsIndicators of building collapse ––EffectsEffects of fire and suppression activities on wood, masonry, cast iron, steel, reinforced concrete, gypsum wallboard, glass and plaster on lath Money, Money, Money….. Everything comes down to MONEY, including building construction. As John Mittendorf says “ Although certain types of building construction are currently popular with architects, modern practices will be inevitably be replaced by newer, more efficient, more costcost--effectiveeffective methods ”” Considerations include: ––CostCost of Labor ––EquipmentEquipment
    [Show full text]
  • Gable End Raking Verge Overhang Options
    01/2017 GABLE END RAKING VERGE OVERHANG OPTIONS Covers raking verge using standard purlin overhang options. Covers up to 750mm overhang using standard verge outriggers. Covers up to 1200mm overhang using verge outrigger/purlin combination. OVERHANG OPTIONS • All gable end loading parameters are based on the design considerations used in NZS 3604:2011 and cover heavy roof weight, extra high wind load and snow load Sg of up to 1.0kPa. • All live load considerations as per AS/NZS 1170. • All timber to be minimum grade SG8 as defined in NZS 3604:2011. CANTILEVER PURLIN OPTION antilever Purlin or atten to extend over at least length 3 rafter/truss supports TABLE 1 PURLIN SIZE & ORIENTATION MAX. CANTILEVER LENGTH (mm) PURLIN CENTRES (mm) 45x45 200 400 70x45 300 900 90x45 450 900 CANTILEVER OUTRIGGER OPTION (Note: Maximum sidewall overhang of 750mm) (See details on next pages) TABLE 2 OUTRIGGER SIZE & ORIENTATION MAX. CANTILEVER LENGTH (mm) OUTRIGGER CENTRES (mm) 750 600 70x45 600 900 750 900 90x45 600 1200 750 400 LENGTH 750mm 90x45 MAX. CANTILEVER 600 600 CANTILEVER OUTRIGGER/PURLIN COMBINATION OPTION (Note: Maximum sidewall overhang of 1200mm) (See details on next pages) TABLE 3 OUTRIGGER SIZE & ORIENTATION MAX. CANTILEVER LENGTH (mm) OUTRIGGER CENTRES (mm) 45x45 Purlin 1200 450 90x45 Outrigger 70x45 Purlin 1200 700 90x45 Outrigger 90x45 Purlin LENGTH 1200mm 1200 900 MAX. CANTILEVER 90x45 Outrigger CONSTRUCTION DETAILS FOR CANTILEVER OUTRIGGER OPTION (SPANS & CENTRES AS PER TABLE 2) antilever length antilever length max 750mm wang to support
    [Show full text]
  • Traditional Gable Freestanding Carport
    TRADITIONAL GABLE FREESTANDING CARPORT STRATCO OUTBACK® ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback TRADITIONAL GABLE CARPORT BEFORE YOU START Carefully read these instructions. If you do not have all the necessary tools or information, contact Stratco for advice. Before starting lay out all components and check them against the delivery docket. The parts description identifies each key part, and the component location diagrams indicates their fastening position. PARTS DESCRIPTION RIDGE KNUCKLE FOOTING PLATE EAVES KNUCKLE FOOTING COLUMNS AND Slots inside the gable rafters to Slots inside column Slots inside gable rafter and KNUCKLE RAFTERS form connection at the ridge to form on concrete column to form connection at Slots inside Pre cut 120 outback footing connection. eaves. column to form beam make up an in ground rafters and columns footing connection PURLINS BARGE CAP RIDGE CAP HEADER FLASHING INFILL PANELS Purlins provide support for The barge cap covers This flashing covers the roof This flashing attaches the infill Sufficient number of sheets are cladding the area where the sheets at the gable ridge. panel to the infill frame. provided, from which the required deck finishes at portal infill panels can be cut. frame PANEL STRIPS HEX HEAD SELF DRILLING BOLTS AND RIVETS Panel strips attach to the SCREWS Bolt types vary depending infill panel where applicable Screw types vary depending upon upon the connection, ensure the connection, ensure correct the correct fixings are used screws are used 10 x 16 12 x 20 14 x 95 ADDITIONAL MATERIALS These items are available at request, they are not included in the basic kit price.
    [Show full text]
  • Dutch Gable Carport Recommended Instruction Manual
    DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL This document remains the property of FBHS (Aust) Pty Ltd September 2015 Table of Contents Introduction 2 Components 3 Step 1a – Marking out the Perimeter of the Carport with Footing only 4 Step 2a – Footing Set-Out for Concrete Block Pad Footing 5 Step 1b – Marking out the Perimeter of the Carport with Slab 6 Step 2b – Footing Set-Out for Concrete Slab 7 Step 3 – Preparation of Carport Posts 8 Step 4a – Post Sleeve on Base Plate Set-out on Footing only 9 Step 4b – Post Sleeve on Base Plate Set-out on Slab 10 Step 5 - Fitting of Intermediate Rafters with Apex Bracket 11 Step 6 - Fitting of End Rafters with Apex Bracket and Cross Beam Assembly 12 Step 7 - Fitting of Columns with Haunch Bracket 14 Step 8 - Fitting of Sidewall Eave Purlin (SW) to Post 15 Step 9 – Fixing of Cover Flashing to Sidewall Eave Purlin (SEP) 16 Step 10 - Gutter 16 Step 11 - Sidewall Frame Assembly 18 Step 12 - Other Sidewall Frame Assembly 18 Step 13- Standing First Sidewall Frame Assembly 18 Step 14 - Standing Second Sidewall Frame Assembly 19 Step 15- Fixing of Endwall Eave Purlin(EEP) to Sidewall Eave Purlin (SEP) on the Rear Endwall 19 Step 16- Installation of Rear Endwall Rafter 20 Step 17- Fixing of Dutch Cross Beam 21 Step 18 - Fixing of Rafter Frame Bracket to Cross Beam End Bracket 21 Step 19 - Fixing of Internal Hip Bracket 22 Step 20 - Fixing of Dutch Hip Rafter 23 Step 21- Fixing of Dutch Hip Rafter to the opposite corner 25 Step 22 - Fixing of Crown Rafter 26 Step 23 - Installation of Intermediate Rafters
    [Show full text]
  • Dutch Gable Freestanding Carport
    DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK® ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If you do not have all the necessary tools or information, contact Stratco for advice. Before starting lay out all components and check them against the delivery docket. The parts description identifies each key part, and the component location diagram indicates their fastening position. PARTS DESCRIPTION RIDGE KNUCKLE FOOTING PLATE EAVES KNUCKLE FOOTING COLUMNS AND Slots inside the gable rafters to Slots inside column Slots inside gable rafter and KNUCKLE RAFTERS form connection at the ridge to form on concrete column to form connection at Slots inside Pre cut 120 outback footing connection. eaves. column to form beam make up an in ground rafters and columns footing connection PURLINS HIP PLATE RIDGE CAP BARGE CAP INFILL PANELS Purlins provide support for Connects purlins to This flashing covers the roof The barge cap covers Sufficient number of sheets are cladding the hip rafter. sheets at the gable ridge. the area where the provided, from which the required deck finishes at portal dutch gable infill panels can be HIP FLASHING frame cut. Covers the roof sheet ends along the hip rafter. WEATHER STRIP HEX HEAD SELF DRILLING BOLTS AND RIVETS 68 mm PURLIN Weather strip supports infill SCREWS Bolt types vary depending BRACKET panel and covers the sheet Screw types vary depending upon upon the connection, ensure This bracket ends at the collar
    [Show full text]
  • Roof Truss – Fact Book
    Truss facts book An introduction to the history design and mechanics of prefabricated timber roof trusses. Table of contents Table of contents What is a truss?. .4 The evolution of trusses. 5 History.... .5 Today…. 6 The universal truss plate. 7 Engineered design. .7 Proven. 7 How it works. 7 Features. .7 Truss terms . 8 Truss numbering system. 10 Truss shapes. 11 Truss systems . .14 Gable end . 14 Hip. 15 Dutch hip. .16 Girder and saddle . 17 Special truss systems. 18 Cantilever. .19 Truss design. .20 Introduction. 20 Truss analysis . 20 Truss loading combination and load duration. .20 Load duration . 20 Design of truss members. .20 Webs. 20 Chords. .21 Modification factors used in design. 21 Standard and complex design. .21 Basic truss mechanics. 22 Introduction. 22 Tension. .22 Bending. 22 Truss action. .23 Deflection. .23 Design loads . 24 Live loads (from AS1170 Part 1) . 24 Top chord live loads. .24 Wind load. .25 Terrain categories . 26 Seismic loads . 26 Truss handling and erection. 27 Truss fact book | 3 What is a truss? What is a truss? A “truss” is formed when structural members are joined together in triangular configurations. The truss is one of the basic types of structural frames formed from structural members. A truss consists of a group of ties and struts designed and connected to form a structure that acts as a large span beam. The members usually form one or more triangles in a single plane and are arranged so the external loads are applied at the joints and therefore theoretically cause only axial tension or axial compression in the members.
    [Show full text]
  • Chapter 3 Design Aids/Standard Forms
    AGRICULTURAL WASTE MANAGEMENT BUILDING DESIGN HANDBOOK 3 - 1 Chapter 3 Design Aids/Standard Forms Figure 3.1 The bin size required is dependent not only the volume of compost, but also on the size and type of mechanical equipment that will be used in the operation. General Effects of Bracing The size of a composting facility should be Lateral bracing (or knee bracing) is used to determined according to Chapter 10 of the increase rigidity in the post-to-rafter or post- Agricultural Waste Management Field to-truss connections. Analysis performed for Handbook (NRCS 1992). The actual bin the development of this handbook shows that size should be determined by the planner. bracing reduces the required member size of Once the bin size is known, the planner can the rafters, but infrequently affects post size use the member sizing charts on the for the shed-type composters, shown in following pages to select the appropriate Figure 3.2, page 3-5. Only the posts in the member sizes. 100 mph wind zone are reduced by bracing. (USDA-NRCS SOUTH CAROLINA 4/14/98) AGRICULTURAL WASTE MANAGEMENT BUILDING DESIGN HANDBOOK 3 - 2 The post sizes in the other zones remain the Frame Connection Details same for this building configuration. Details on how to connect the braces are included with the Construction Drawings in Figure 3.9 for composters (page 3-15) and Appendices. Figure 3.11 for stacking sheds (page 3-20) tabulate the correct number of fasteners for Analysis shows that the required post size each type of frame connection.
    [Show full text]
  • NOTICE to CONTRACTORS 11-005 Proper Roof Bracing Update Per IRC R802.5.1 (This Notice Replaces Notice 08-005) Effective: Immediately Distributed on March 11, 2011
    NOTICE TO CONTRACTORS 11-005 Proper Roof Bracing Update Per IRC R802.5.1 (This Notice replaces Notice 08-005) Effective: Immediately Distributed on March 11, 2011 This NOTICE TO CONTRACTORS contains important information for builders and contractors that do business in the City of Stillwater. Please circulate this to others in your organizations and to your sub-contractors as may be applicable. Issue: Proper Roof Bracing Clarification and Detail Applicable Code Section(s): R802.5.1 Purlins. Purlins are permitted to be installed to reduce the span of rafters as shown in Figure R802.5.1. Purlins shall be sized no less than the required size of the rafters that they support. Purlins shall be continuous and shall be supported by 2-inch by 4-inch (51 mm by 102 mm) braces installed to bearing walls at a slope not less than 45 degrees from the horizontal. The braces shall be spaced not more than 4 feet (1219 mm) on center for 2-inch by 4-inch (51 mm by 102 mm) or 6 feet (1829 mm) on center for 2-inch by 6-inch (51 mm by 152 mm) and the unbraced length of braces shall not exceed 8 feet (2438 mm). R802.3 Framing details. Rafters shall be framed to ridge board or to each other with a gusset plate as a tie. Ridge board shall be at least 1-inch (25.4 mm) nominal thickness and not less in depth than the cut end of the rafter. At all valleys and hips there shall be a valley or hip rafter not less than 2-inch (51mm) nominal thickness and not less in depth than the cut end of the rafter.
    [Show full text]
  • Builder's Guide to Trusses
    Table of Contents Roof Construction Techniques: Pro’s and Con’s . 2 Trusses: Special Benefits for Architects and Engineers . 4 Special Benefits for Contractors and Builders . 5 Special Benefits for the Owner. 5 How Does A Truss Work? . 6 Typical Framing Systems. 8 Gable Framing Variations . 11 Hip Set Framing Variations . 13 Additional Truss Framing Options Valley Sets . 15 Piggyback Trusses . 17 Typical Truss Configurations . 18 Typical Truss Shapes. 20 Typical Bearing / Heel Conditions Exterior Bearing Conditions. 21 Crushing at the Heel . 22 Trusses Sitting on Concrete Walls . 22 Top Chord Bearing. 23 Mid-Height Bearing . 23 Leg-Thru to the Bearing. 23 Tail Bearing Tray. 24 Interior Bearing Conditions . 24 Typical Heel Conditions. 25 Optional End Cosmetics Level Return. 25 Nailer . 25 Parapet. 26 Mansard . 26 Cantilever. 26 Stub . 26 Bracing Examples . 27 Erection of Trusses . 29 Temporary Bracing . 30 Checklist for Truss Bracing Design Estimates . 32 Floor Systems . 33 Typical Bearing / Heel Conditions for Floor Trusses Top Chord, Bottom Chord, and Mid-Height Bearing. 34 Interior Bearing Conditions . 35 Ribbon Boards, Strongbacks and Fire Cut Ends . 36 Steel Trusses . 37 Ask Charlie V. 38 Charlie’s Advice on Situations to Watch Out for in the Field. 41 Glossary of Terms. 42 Appendix - References. 48 1 Builders, Architects and Home Owners today have many choices about what to use in roof and floor systems Traditional Stick Framing – Carpenters take 2x6, Truss Systems – in two primary forms: 2x8, 2x10 and 2x12 sticks of lumber to the job • Metal Plate Connected Wood Trusses – site. They hand cut and fit this lumber together Engineered trusses are designed and into a roof or floor system.
    [Show full text]
  • Dutch Gable Carport
    Instruction Manual 19/9/01 Dutch Gable Carport Thank you for choosing this quality carport. We strongly recommend that you read these instructions thoroughly. The carport you are building may vary from a carport previously bought or those displayed as we are constantly upgrading designs and construction methods. Please take your time to and do not rush the erection of your new carport and you will ensure a finished product of which you may be justly proud. Due to the large range of sizes and styles available, it is impossible to prepare an instruction manual for each individual size and model. The following instructions relate to a 6m wide and 6m long carport. This manual is a guide only and should be used in conjunction with the components list and engineers plans as submitted to council. Frame Components Haunch Plates – Left hand and right hand: Galvanised “Boomerang” shaped plate to join columns to roof rafters. Haunch plate must always be installed on the smooth side of the rafters. LEFT SIDE RIGHT SIDE Apex Plates: For joining rafters to form apex to roof. AG&S Building Systems P/L/Hi-Tech Designs P/L 1 PO Box 252 CAMDEN NSW 2570 For any enquiries, contact your local distributor. Instruction Manual 19/9/01 C Purlins: “C” section purlin. Used as rafters, eave purlins, cross beams, apex cross beams, hip beams and awning beams. Smooth side of rafter and apex cross beam must face inside of carport Carport Flashing: Fitted to open side of eave purlins and cross bars. Columns: 75mm x 75mm square tube.
    [Show full text]
  • How to Build Safe Roofs with Corrugated Galvanized Iron (CGI) Sheeting
    How to build safe roofs with corrugated galvanized iron (CGI) sheeting ifrc-sru.org Shelter Research Unit Innovating shelter HOW TO BUILD SAFE ROOFS WITH COrrUGATED GALVANIZED IRON (CGI) SHEETING IMPORTANT NOTICE T he information provided in this manual and the calculations are based on up to date material specifications, field testing and current practice of calculating structures (using Eurocodes 1, 3 and 5) and must be treated as guidelines only and evaluated for suitability in the context of specific local conditions. Risk is inherent in construc- tion and especially after natural disaster caution must be exercised so as not to increase the threat to disaster affected persons. Users of this manual do so solely at their own risk. The International Federation of the Red Cross and Red Crescent societies – Shelter Research Unit (IFRC-SRU) nor any of it’s employees or technical consultants assume any liability for damages, loss or claims, of any nature, including the death or injury of persons or property damage, associated with the use of or reliance upon information contained in this manual. This publication has been made possible through the generous support of: Belgian Red Cross, Flemish and French speaking communities: Contents T ABLE OF CONTENTS Acknowledgements 11 Foreword 13 About this manual 14 Structure of the manual 15 For whom is this manual? 16 Technical terms used in this manual 17 Glossary of Terms (Alphabetical) 23 Acronyms 26 SECTION A Materials 29 A.1 Corrugated Roofing Materials 29 A.2 Corrugated Galvanized Iron or Steel (CGI) sheets 32 A.2.1. Dimensions and measurement for CGI sheets 33 A.2.2.
    [Show full text]
  • Stramit Purlins, Girts and Bridging Detailing and Installation Guide
    STRAMIT ® PURLINS , GIRTS & BRIDGING DETAILING & INSTALLATION detailing & installation guide PGB – DI STRAMI T® PURLINS, GIRTS & BRIDGING DETAILING & INSTALLATION Guide to detailing and installation of Strami t ® Purlins, Girts & Bridging and their accessories. IMPORTANT NOTICE AND DISCLAIMER The information contained within this brochure is intended for general use and information only. Before application in a particular situation, Stramit recommends that you obtain appropriate independent qualified expert advice confirming the suitability of product(s) and information in question for the application proposed. While Stramit accepts its legal obligations, be aware however that to the extent permitted by law, Stramit disclaims all liability (including liability for negligence) for all loss and damage resulting from the direct or indirect use, or reliance on, the information provided in this brochure. CONTENTS INTRODUCTION Selection and Specification This Detailing and Installation Guide is complementary Materials 2 to the Stramit® Purlins, Girts & Bridging – Product Adverse Conditions 2 Technical Manual (incorporating design capacity tables). Compatibility 2 The Guide contains details on all Stramit® Purlins, Specification 2 Girts, Bridging and relevant accessories. Information is Structural Adequacy 2 provided to enable detailed purlin design including a wide range of practical component assemblies to cover Design Data - Stramit® Purlin Accessories Sizes 3 almost all applications. Hole Punching 4 Stramit offers a wide range of standard C and Z purlins Bridging Hole Location 5 from 100 to 350 deep in several thicknesses. Downturn Laps 5 lips are also available for both C and Z sections from Expansion Joints 6 150 to 350, including lappable Zs. Special sizes from 100 Detailing of Purlins 6 to 400 are also possible.
    [Show full text]