OPTIMIZING THE PERFORMANCE OF AUTOMATED MONITORING SYSTEMS FOR AIRBORNE TOXIC CHEMICALS

Dr. Gary D. Sides August 5, 2014

1 Topics

• Introduction • Evolution of automated air monitoring systems for chemical agents • Derivatization methods successfully employed • Improved understanding of a mature detector

2 U.S. Stockpile of Chemical Weapons

• In 1994, the US stockpile of chemical weapons was formally declared in response to the U.S. signing the Chemical Weapons Convention in 1993. • The US stockpile consisted of a total of 31,000 tons of (GB), mustard (HD), and agent VX and small quantities of (L) and (GA). • As of 2014, only about 3,135 tons of the US stockpile remains to be destroyed: —2,611 tons of HD at —306 tons of GB, 127 tons of VX, and 91 tons of HD at Bluegrass Army Depot

3 Examples of activities at disposal sites requiring the protection of workers, the general public, and the environment

4 Primary Roles of Chemical Agent Monitoring*

• To detect chemical agent and sound an alarm if concentrations greater than the applicable airborne exposure limit are reported as the result of the failure of a system, operation, or process • To provide an early warning of a problem that may result in the detection of agent outside engineering controls before the applicable airborne exposure limit is exceeded (by the use of monitoring trends) • To ensure the use of appropriate PPE (personal protective equipment) for the area in which workers will be located (based on monitoring conducted prior to entry)

*Also ensures that site personnel will be able to take appropriate actions immediately, in the event of the detection of agent to ensure the protection of workers, the general public, and the environment.

5 Airborne Exposure Limits (AELs) mg/m3

GPL WPL STEL SEL IDLH

GB 0.000001 0.00003 0.0001 0.0003 0.1

VX 0.0000006 0.000001 0.00001 0.0003 0.003

HD 0.00002 0.0004 0.003 0.03 0.7

GB (Sarin) VX HD (Mustard)

6 Airborne Exposure Limits (AELs) parts per trillion by volume*

GPL WPL STEL** SEL IDLH

GB 0.17 5.2 17 52 17

VX 0.055 0.091 0.91 27 270

HD 3.1 61 460 4,600 110,000

*To meet quality requirements, air monitoring methods must be capable of monitoring concentrations as low as 0.2 AEL.

**Also, known as the Vapor Screening Limit (VSL), when used to clear decontaminated items.

7 AUTOMATED AIR MONITORING SYSTEMS

8 Automatic Continuous Air Monitoring System (ACAMS)

Automated monitoring system based on: • Collection of the chemical agent of interest using an internal solid-sorbent tube • Separation of the agent from other chemicals Courtesy of Meadoworks, Inc., Rupert, West Virginia using, capillary gas chromatography • Detection using a flame photometric detector (FPD)

ß time

The ACAMS reports the chemical agent concentration once every 5 min.

9 ACAMS – a well proven, mature technology

• First developed for use at the CAMDS disposal site, (DCD), in 1980 • Used at the JACADS chemical agent disposal site, Johnston Atoll, 1990-1996 • Used at other agent disposal sites (ANCDF, PBCDF, TOCDF, and UMCDF), 1994-2013

10 Previous Generations

• Automatic Continuous Air Monitoring System (ACAMS) —Developed by Dr. Sides at Southern Research Institute (1980-1986)

—Used at five incinerator-based agent disposal sites (CMA)

—65 pounds, 1.7 cu. ft., twelve (12) circuit boards, complex wiring

—Complex GC-based sampling and analytical system

• Miniature Automatic Continuous Air Monitoring System (MINICAMS®) —Developed by Dr. Sides, founder of CMS Research Corporation (1986-1998)

—Used at four alternative technologies agent disposal sites (ACWA)

—18 pounds, 0.9 cu. ft., six (6) through-hole circuit boards, complex wiring

—Moderately complex GC-based sampling and analytical system

MINICAMS® is a registered trademark of CMS Research Corporation, Pelham, Alabama

11 Air Alert – A third generation air monitoring system from Gary Sides

• Flexible sampling and analytical platform with space for expansion

• Sampling and analytical components plug-in for ease of replacement

• Readily reconfigured for various applications (removable module)

• Only two surface-mount circuit boards

• Only six simple wiring harnesses

• Lower cost of manufacturing

• Reduced weight (13 pounds)

• 0.7 cubic feet

12

Air Alert with an FPD

• Sampling and analytical module with a flame photometric detector (FPD)

• Detection of sulfur- and phosphorus-containing organic chemicals

13 Air Alert with a CSD

• Sampling and analytical module with a selective detector (CSD)

• Detection of chlorine-containing organic chemicals

14 Air Alert Data Acquisition System

15 DERIVATIZATION AND THE DETECTION OF AIRBORNE AGENT VX

16 Determination of Agent VX

O O CH(CH 3) 2 CH(CH 3) 2

H 3 C - P - S - CH 2CH 2 - N + AgF H 3 C - P - F + Ag - S - CH 2 CH 2 - N

CH(CH 3) 2 CH(CH 3) 2 OCH 2CH 3 OCH 2 CH 3

• 15-min STEL concentration is less than one part per trillion • VX vapor pressure is about 0.0007 mmHg at 20 C • VX is a polar molecule and difficult to transport through sample tubing

O O 3 2 3 2 CH(CH ) CH(CH )

H 3 C - P - S - CH 2CH 2 - N + AgF H 3 C - P - F + Ag - S - CH 2 CH 2 - N

CH(CH 3) 2 CH(CH 3) 2 OCH 2CH 3 OCH 2 CH 3

B. Saville, The Concerted Action of Fluoride and Silver Ions on Diethyl Ethylphosphonothiolate in Aqueous Solution, J. Chem. Soc., 1961, 4624-4630.

17 Determination of Agent VX

O O CH(CH 3) 2 CH(CH 3) 2

H 3 C - P - S - CH 2CH 2 - N + AgF H 3 C - P - F + Ag - S - CH 2 CH 2 - N

CH(CH 3) 2 CH(CH 3) 2 OCH 2CH 3 OCH 2 CH 3 VX G-analog of VX

18 Determination of GA (Tabun)

O O AgNO3 N P CN N P F + AgCN KF O O

GA Fluorotabun (FT)

GB “GA”

“VX”

19 DERIVATIZATION, A DETECTOR CHANGE, AND AIRBORNE LEWISITE I

20 Goal of the Initial Development of a Lewisite Monitoring System at CMS Research in the Mid 1990s

• Develop the ability to monitor for Lewisite 1 at its 15-min STEL concentration (0.003 mg/m3 or 3 ng/L) using a modified MINICAMS.

Cl Volatility (mg/m3): As Lewisite 1 ~2500 @ 20 C

Cl Cl Mustard (HD) ~600 @ 20 C Challenges: • Reactive (hydrolysis) and thermally labile, Lewisite 1 cannot be thermally desorbed from a porous polymer sorbent bed • Thermally labile, Lewisite 1 is difficult to determine by GC • MINICAMS in early 1990s was configured only with a flame photometric detector (S or P)

21 Lewisite 1 Normally Derivatized Prior to Determination by Gas Chromatography

• Reaction with British Anti-Lewisite (2,3-dimercapto-1-propanol)

Cl HS S As + As + 2 HCl Cl Cl HS Cl S OH OH • Reaction with 1,2-ethanedithiol (EDT) in solution to form “LD”

Cl HS S As + As + 2 HCl Cl Cl HS Cl S

• Challenge: Near-real-time derivatization (gas phase or on a substrate)

22 Typical FPD-MINICAMS Chromatogram for a Lewisite Challenge (with EDT in gas phase)

S As Cl S

Chromatogram courtesy of Sandra Macon, CMS Field Products (OICO)

23 FPD-MINICAMS Chromatogram for a Lewisite Challenge (with a higher EDT concentration)

S As Cl S

Chromatogram courtesy of Sandra Macon, CMS Field Products (OICO)

24 OICO’s Halogen Selective Detector (XSD), Developed in 1995, Adapted to MINICAMS

S As Cl S

• Selective for chlorine • MDL < 0.1 ng chlorine • Supplied EDT (200 ppmv in nitrogen) from a compressed gas cylinder

25 Chromatogram for a Lewisite Challenge Obtained Using an XSD-MINICAMS

S As Cl S

Chromatogram courtesy of Sandra Macon, CMS Field Products (OICO) 26 IMPROVED UNDERSTANDING OF A MATURE DETECTOR

27 Halogen Selective Detector (XSD)

• Response assumed linear for the concentration ranges of interest • Data quality objectives (DQOs) passed but with some issues • DQOs could not be met reliably when concentration range of interest was increased

28 OICO Applications Note for the XSD

§ Response linear and through origin (0,0) only at low masses § Response non-linear at higher masses

OICO Applications Note 16561101, entitled “Using the Halogen Specific Detector (XSDTM) as an Alternative to the ELCD in USEPA Methods”

29

OICO Notes on Operation of the XSD September 2, 1994 – Dr. Rich Simon, Developer of the XSD at OICO

Langmuir adsorption model

α (VSL) H = 1 + β (VSL)

where α and β are constants and H is the peak height

*For a sample flow rate of 450 mL/min and sample period of 3 min

30 Dale Coulson’s Patent – 1991

31 SRI Instruments (Las Vegas, Nevada) Licensed Dale Coulson’s Detector

• Sold as the Dry Electrolytic Conductivity Detector (DELCD)

• Response linear and through origin (0,0) only at low masses

• Response non-linear at higher masses

Data from Xiaojing Li (2009) Data from Xiaojing Li (2009)

32 Accounting for Non-Linearity of the XSD

• Langmuir response can be approximated over the concentration range of interest using a standard feature of the MINICAMS software

Concn = (Peak Height/CAL Height)1/n

• Data quality objectives were then easily met

33 To Optimize Instrument Performance

• Constant development and improvement in hardware and embedded code required

• Willingness to consider derivatization methods important

• Willingness to question current practices (assumptions) important

34