Length Measuring Machine General Catalog

Total Page:16

File Type:pdf, Size:1020Kb

Length Measuring Machine General Catalog LENGTH MEASURING MACHINE GENERAL CATALOG E-PEAK15 - Origin of KANON Mark - The KANON mark is a symbol of technology of Nakamura Mfg. Co., Ltd., which was established at the time of foundation. Kanon is a Latin word that means“Standard.” We selected this word because we think that our products on which the KANON mark is printed must be“KANON” of all measuring equipment, namely the best model product. Note that the specifications may be changed without prior notice. Dealer 4-4, Ohi 4-chome, Shinagawa-ku, Tokyo 140-0014, Japan TEL: +81-3-3775-1527 FAX: +81-3-3775-1732 E-MAIL: [email protected] URL: http://www.bestool-kanon.co.jp/english/ 2016.2-3000 LENGTH MEASURING MACHINE GENERAL CATALOG INDEX Digital caliper holding E-PEAK digital caliper E-PEAK 2 Min and Max measured value E-PITA (flat-head digital caliper) / PITA (flat-head vernier caliper) 3 E-PEAK Flat-head caliper ULJ (judgment) 4 Adequate for narrow space where the display is hard to see 5 PLUS10 REGISTERED AS UTILITY MODEL (Japan) Large-size digital caliper, dial caliper EMA / DMK-J 6 E-RX / E-RZ 7 E-RM-J 8 Caliper for measuring E-RX-J / RM-DX 9 circular hole pitch RM(ⅠⅠ) / RM-S 10 E-RM60B / E-RM30DX 11 E-RM(ⅠⅠ) / E-RM-S / special-purpose gage block 12 E-DP-J / E-DP2J (extra thin) 13 Digital depth gauge Overall length E-TH (E-thin hole) / E-RD (cave) 14 E-LSDM / LSDM 15 E-PEAK15 ESDM / SDM 16 Depth gage BSDM / BSD-P 17 SD-P / TH (thin hole) 18 KSM-FF / SM 19 Popular vernier caliper M / M60P 20 Caliper with curre jaw E-RA (E-curre jaw) / RA (curre jaw) 21 Maximum values and minimum values are automatically stored. Caliper for narrow space E-ROBA / ROBA 22 Long jaw caliper E-LSM / LSM 23 Inside caliper E-ICM-J / E-ICM / ICM 24 For measuring inner diameter, the maximum value (Max) mode Digital blade caliper E-BL 25 is convenient! Digital wide caliper E-WK 25 Digital point vernier caliper E-PK 26 99.98 ● On former vernier calipers, ● The maximum value of inner Digital pipe caliper E-PM 26 users search the maximum 100.00 diameter is automatically value as a numerical value. stored in an E-PEAK vernier Digital neck caliper E-NK 26 99.98 caliper. Flange caliper FCM (for inspection) / FBM (for working) 27 Short leg caliper SBM 28 Inspection instrument SNAP GAGE 28 Vernier caliper SCM / SCML 29 Digital scale ES-B / TES 30 For measuring outer diameter at a dark location, the minimum Digital height gage EHK30J 31 value (Min) mode is convenient! Reading at hand Printer TPK-3 32 Lathe turning (Posture for reading caliper is hard.) Scriber Scriber / Rotating scriber 32 Height gage SHT-3 / SHT-1 33 Measurement at the back of processing machine One-axis measuring machine (straight line) 34 (difficult to see the display) X-600 / X-1000 Convenient in such cases! Vision measuring machine EXLON-y 35 100.18 Coordinate measuring machine ⅠⅠⅠ 36 Measurement of EXLON-Z 453 100.00 ● The minimum value of outer width of large groove 100.22 BESTOOL-KANON Kanon About vernier calipers 37・38 diameter is automatically stored in an E-PEAK vernier caliper. Japanese Industrial Standards JIS About vernier calipers 39・40 SM・M type / KSM type / SCM type 41・42 Parts list ■ E-PEAK:Specifications (Unit : mm) type / type / type 43・44 SDM SHT-3 SHT-1 Model Measuring length Resolution Instrumental error Overall length Power supply Weight A B C D E F G H E-PEAK15 150 241 170g 234 16 76 40 14 30 7 3.8 ±0.02 SR44 E-PEAK20 190g 284 16 76 40 14 30 7 3.8 200 0.01 291 1 piece E-PEAK30 300 ±0.03 396 280g 388 16 103 64 14 47 8 4.8 ←"ONLY ONE": Products with this red mark are BESTOOL-KANON completely original products. For special size or special specification products from products listed in this catalog, we accept request of estimate and order. Contact our company or your dealers, 1 2 LENGTH MEASURING MACHINE GENERAL CATALOG INDEX Digital caliper holding E-PEAK digital caliper E-PEAK 2 Min and Max measured value E-PITA (flat-head digital caliper) / PITA (flat-head vernier caliper) 3 E-PEAK Flat-head caliper ULJ (judgment) 4 Adequate for narrow space where the display is hard to see 5 PLUS10 REGISTERED AS UTILITY MODEL (Japan) Large-size digital caliper, dial caliper EMA / DMK-J 6 E-RX / E-RZ 7 E-RM-J 8 Caliper for measuring E-RX-J / RM-DX 9 circular hole pitch RM(ⅠⅠ) / RM-S 10 E-RM60B / E-RM30DX 11 E-RM(ⅠⅠ) / E-RM-S / special-purpose gage block 12 E-DP-J / E-DP2J (extra thin) 13 Digital depth gauge Overall length E-TH (E-thin hole) / E-RD (cave) 14 E-LSDM / LSDM 15 E-PEAK15 ESDM / SDM 16 Depth gage BSDM / BSD-P 17 SD-P / TH (thin hole) 18 KSM-FF / SM 19 Popular vernier caliper M / M60P 20 Caliper with curre jaw E-RA (E-curre jaw) / RA (curre jaw) 21 Maximum values and minimum values are automatically stored. Caliper for narrow space E-ROBA / ROBA 22 Long jaw caliper E-LSM / LSM 23 Inside caliper E-ICM-J / E-ICM / ICM 24 For measuring inner diameter, the maximum value (Max) mode Digital blade caliper E-BL 25 is convenient! Digital wide caliper E-WK 25 Digital point vernier caliper E-PK 26 99.98 ● On former vernier calipers, ● The maximum value of inner Digital pipe caliper E-PM 26 users search the maximum 100.00 diameter is automatically value as a numerical value. stored in an E-PEAK vernier Digital neck caliper E-NK 26 99.98 caliper. Flange caliper FCM (for inspection) / FBM (for working) 27 Short leg caliper SBM 28 Inspection instrument SNAP GAGE 28 Vernier caliper SCM / SCML 29 Digital scale ES-B / TES 30 For measuring outer diameter at a dark location, the minimum Digital height gage EHK30J 31 value (Min) mode is convenient! Reading at hand Printer TPK-3 32 Lathe turning (Posture for reading caliper is hard.) Scriber Scriber / Rotating scriber 32 Height gage SHT-3 / SHT-1 33 Measurement at the back of processing machine One-axis measuring machine (straight line) 34 (difficult to see the display) X-600 / X-1000 Convenient in such cases! Vision measuring machine EXLON-y 35 100.18 Coordinate measuring machine ⅠⅠⅠ 36 Measurement of EXLON-Z 453 100.00 ● The minimum value of outer width of large groove 100.22 BESTOOL-KANON Kanon About vernier calipers 37・38 diameter is automatically stored in an E-PEAK vernier caliper. Japanese Industrial Standards JIS About vernier calipers 39・40 SM・M type / KSM type / SCM type 41・42 Parts list ■ E-PEAK:Specifications (Unit : mm) type / type / type 43・44 SDM SHT-3 SHT-1 Model Measuring length Resolution Instrumental error Overall length Power supply Weight A B C D E F G H E-PEAK15 150 241 170g 234 16 76 40 14 30 7 3.8 ±0.02 SR44 E-PEAK20 190g 284 16 76 40 14 30 7 3.8 200 0.01 291 1 piece E-PEAK30 300 ±0.03 396 280g 388 16 103 64 14 47 8 4.8 ←"ONLY ONE": Products with this red mark are BESTOOL-KANON completely original products. For special size or special specification products from products listed in this catalog, we accept request of estimate and order. Contact our company or your dealers, 1 2 Pass/fail judgment function is added to Epoch-making flat-head caliper E-PITA/PITA ULJ Judgement flat-head caliper. 21st century version of standard caliper! Flat-head vernier caliper series JUDGEMENT With“Flat head”, measurement can be conducted easily from any corners. With "Judgment function", instantaneous sorting of accepted products and rejected products is available. E-PITA15 Overall length Overall length ● Complete renewal of design and various types ULJ15 of size provide a wider range of use! ■ E-PITA : Specifications (Unit : mm) Model Measuring length Resolution Instrumental error Overall length Power supply Weight A B C D E F G H E-PITA10 100 191 160g 184 16 76 40 14 30 7 3.8 Measurement of Measurement of Measurement E-PITA15 150 ±0.02 241 170g 234 16 76 40 14 30 7 3.8 SR44 internal dimension external dimension of depth E-PITA20 200 0.01 291 190g 284 16 76 40 14 30 7 3.8 1 piece E-PITA30 300 ±0.03 396 280g 388 16 103 64 14 47 8 4.8 E-PITA40 400 ±0.05 496 400g 488 16 103 64 14 47 8 *E-PITA40 is not equipped with any depth bar. ■ E-PITA : Metric / Inch model Specifications (Unit : mm) Model Measuring length Resolution Instrumental error Overall length Power supply Weight A B C D E F G H E-PITA150×6″ 150mm×6″ 0.01mm 241 170g 234 16 76 40 14 30 7 3.8 ±0.02 SR44 × E-PITA200×8″ 200mm×8″ 291 1 piece 190g 284 16 76 40 14 30 7 3.8 E-PITA300×12″300mm×12″ 0.0005″ ±0.03 396 280g 388 16 103 64 14 47 8 4.8 ● For sorting accepted parts and rejected parts from a large quantity of parts or the like, the working time can In addition to normal measurement, be largely reduced relative to former products.
Recommended publications
  • Check Points for Measuring Instruments
    Catalog No. E12024 Check Points for Measuring Instruments Introduction Measurement… the word can mean many things. In the case of length measurement there are many kinds of measuring instrument and corresponding measuring methods. For efficient and accurate measurement, the proper usage of measuring tools and instruments is vital. Additionally, to ensure the long working life of those instruments, care in use and regular maintenance is important. We have put together this booklet to help anyone get the best use from a Mitutoyo measuring instrument for many years, and sincerely hope it will help you. CONVENTIONS USED IN THIS BOOKLET The following symbols are used in this booklet to help the user obtain reliable measurement data through correct instrument operation. correct incorrect CONTENTS Products Used for Maintenance of Measuring Instruments 1 Micrometers Digimatic Outside Micrometers (Coolant Proof Micrometers) 2 Outside Micrometers 3 Holtest Digimatic Holtest (Three-point Bore Micrometers) 4 Holtest (Two-point/Three-point Bore Micrometers) 5 Bore Gages Bore Gages 6 Bore Gages (Small Holes) 7 Calipers ABSOLUTE Coolant Proof Calipers 8 ABSOLUTE Digimatic Calipers 9 Dial Calipers 10 Vernier Calipers 11 ABSOLUTE Inside Calipers 12 Offset Centerline Calipers 13 Height Gages Digimatic Height Gages 14 ABSOLUTE Digimatic Height Gages 15 Vernier Height Gages 16 Dial Height Gages 17 Indicators Digimatic Indicators 18 Dial Indicators 19 Dial Test Indicators (Lever-operated Dial Indicators) 20 Thickness Gages 21 Gauge Blocks Rectangular Gauge Blocks 22 Products Used for Maintenance of Measuring Instruments Mitutoyo products Micrometer oil Maintenance kit for gauge blocks Lubrication and rust-prevention oil Maintenance kit for gauge Order No.207000 blocks includes all the necessary maintenance tools for removing burrs and contamination, and for applying anti-corrosion treatment after use, etc.
    [Show full text]
  • Calibration Scope
    Laboratory Shanmugha Precision Forging (A Unit of Vee See Bee Trust), Shanmugha Complex, Thirumalaisamudram, Thanjavur, Tamil Nadu Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2402 Page 1 of 3 Validity 06.10.2017 to 05.10.2019 Last Amended on - Sl. Quantity Measured / Range/Frequency *Calibration Measurement Remarks Instrument Capability (±) MECHANICAL CALIBRATION I. DIMENSION (BASIC MEASURING INSTRUMENT, GAUGE ETC.) 1. Caliper Using Caliper Checker Vernier/Dial/Digital$ IS 3651: 1982 L.C.: 0.01mm Upto 600 mm 14.59 m P1(Reaffirmed 2010) , L.C.: 0.02 mm Upto 600 mm 15.83 m IS 3651: 1985 P2 (Reaffirmed 2010) & IS 3651: 1988 P3 (Reaffirmed 2008) 2. Depth Caliper Using Gauge Block Set Vernier / Dial /Digital$ On Surface Plate By L.C.: 0.020 mm Upto 150 mm 13.47 m Comparison Method IS 4213: 1991 (Reaffirmed 2010) 3. Height Gauge Using Caliper Checker Vernier / Dial / IS 2921 : 2016 Digital$ L.C.: 0.010 mm 0 to 300 mm 12.02 m L.C.: 0.020 mm 0 to 600 mm 17.3 m 4. External Micrometer $ Using Gauge Block Set L.C.: 0.001 mm Upto 150 mm 1.96 m Based On Comparison L.C.: 0.01 mm Upto 300 mm 8.55 m Method IS 2967: 1983 (Reaffirmed 2008) 5. Depth Micrometer$ Using Gauge Block Set L.C.: 0.01 mm Upto 150 mm 8.2 m Based On Comparison Method Rajeshwar Kumar Avijit Das Convenor Program Director Laboratory Shanmugha Precision Forging (A Unit of Vee See Bee Trust), Shanmugha Complex, Thirumalaisamudram, Thanjavur, Tamil Nadu Accreditation Standard ISO/IEC 17025: 2005 Certificate Number CC-2402 Page 2 of 3 Validity 06.10.2017 to 05.10.2019 Last Amended on - Sl.
    [Show full text]
  • Vernier Caliper and Micrometer Computer Models Using Easy Java Simulation and Its Pedagogical Design Features—Ideas for Augmenting Learning with Real Instruments
    Wee, Loo Kang, & Ning, Hwee Tiang. (2014). Vernier caliper and micrometer computer models using Easy Java Simulation and its pedagogical design features—ideas for augmenting learning with real instruments. Physics Education, 49(5), 493. Vernier caliper and micrometer computer models using Easy Java Simulation and its pedagogical design feature-ideas to augment learning with real instruments Loo Kang WEE1, Hwee Tiang NING2 1Ministry of Education, Educational Technology Division, Singapore 2 Ministry of Education, National Junior College, Singapore [email protected], [email protected] Abstract: This article presents the customization of EJS models, used together with actual laboratory instruments, to create an active experiential learning of measurements. The laboratory instruments are the vernier caliper and the micrometer. Three computer model design ideas that complement real equipment are discussed in this article. They are 1) the simple view and associated learning to pen and paper question and the real world, 2) hints, answers, different options of scales and inclusion of zero error and 3) assessment for learning feedback. The initial positive feedback from Singaporean students and educators points to the possibility of these tools being successfully shared and implemented in learning communities, and validated. Educators are encouraged to change the source codes of these computer models to suit their own purposes, licensed creative commons attribution for the benefit of all humankind. Video abstract: http://youtu.be/jHoA5M-_1R4 2015 Resources: http://iwant2study.org/ospsg/index.php/interactive-resources/physics/01-measurements/5-vernier-caliper http://iwant2study.org/ospsg/index.php/interactive-resources/physics/01-measurements/6-micrometer Keyword: easy java simulation, active learning, education, teacher professional development, e–learning, applet, design, open source physics PACS: 06.30.Gv 06.30.Bp 1.50.H- 01.50.Lc 07.05.Tp I.
    [Show full text]
  • Vernier Scale 05/31/2007 04:10 PM
    Vernier Scale 05/31/2007 04:10 PM 1. THE VERNIER SCALE Equipment List: two 3 X 5 cards one ruler incremented in millimeters What you will learn: This lab teaches how a vernier scale works and how to use it. I. Introduction: A vernier scale (Pierre Vernier, ca. 1600) can be used on any measuring device with a graduated scale. Most often a vernier scale is found on length measuring devices such as vernier calipers or micrometers. A vernier instrument increases the measuring precision beyond what it would normally be with an ordinary measuring scale like a ruler or meter stick. II. How a vernier system works: A vernier scale slides across a fixed main scale. The vernier scale shown below in figure 1 is subdivided so that ten of its divisions correspond to nine divisions on the main scale. When ten vernier divisions are compressed into the space of nine main scale divisions we say the vernier-scale ratio is 10:9. So the divisions on the vernier scale are not of a standard length (i.e., inches or centimeters), but the divisions on the main scale are always some standard length like millimeters or decimal inches. A vernier scale enables an unambiguous interpolation between the smallest divisions on the main scale. Since the vernier scale pictured above is constructed to have ten divisions in the space of nine on the main scale, any single division on the vernier scale is 0.1 divisions less than a division on the main scale. http://nebula.deanza.fhda.edu/physics/Newton/4A/4ALabs/Vernier_Scale.html Page 1 of 5 Vernier Scale 05/31/2007 04:10 PM scale, any single division on the vernier scale is 0.1 divisions less than a division on the main scale.
    [Show full text]
  • Measurement Instruments: BATY
    precision measuring instruments Baty International has been in business since 1932. Tel +44 (0) 1444 235621 Originally, a manufacturer of high precision dial indicators and other associated instruments such as cylinder bore Fax +44 (0) 1444 246985 gauges. Baty soon diversified into non-contact measurement with Email: [email protected] Optical Profile Projectors and the Baty ‘Shadograph’ series Website: www.baty.co.uk has since become an industry standard in profile projectors. These products are still manufactured in Sussex in accordance with ISO 9001:2000. For decades Baty has employed a team of Field Based Service Engineers. Today, our service department is the largest ISO 9001:2000 accredited Projector Service Organisation in the UK offering on-site Service, Training, Retrofits, and Repair for all makes of Profile Projector and Vision Systems. In keeping with its gauging roots, Baty acquired John Bull and British Indicators, extending its gauging range to include calipers and flexible fixturing. The range was then completed in the eighties when our first camera based Video Inspectors were developed. Video Edge Detection (VED) was soon added giving rise to increased accuracy, repeatability and measuring speed. Now all our vision systems offer the best of both worlds with the combination of non-contact (VED) and contact measurement using Renishaw’s extensive touch probe range. Today, Baty is an ISO 9001:2000 accredited company that offers a range of Metrology Instruments from Hand Tools to Vision Systems, offering measuring solutions for almost every measurement application in modern manufacturing and now, we’ve put them together into one catalogue for your convenience.
    [Show full text]
  • Dimensional Calibration Under Mechanical Discipline
    NABL 122-01 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE: Dimensional Metrology MASTER COPY Reviewed by Approved by Quality Officer Director, NABL ISSUE No. : 06 AMENDMENT No. : -- ISSUE DATE: 12-Apr-2018 AMENDMENT DATE: -- AMENDMENT SHEET Sl Page Clause Date of Amendment Reasons Signature Signature no No. No. Amendment made QM CEO 1 2 3 4 5 6 7 8 9 10 National Accreditation Board for Testing and Calibration Laboratories Doc. No: NABL 122-01 Specific Criteria for Calibration Laboratories in Mechanical Discipline – Dimensional Metrology Issue No: 06 Issue Date: 12-Apr-2018 Amend No: 00 Amend Date: - Page No: 1 of 34 Sl. No. Contents Page No. 1 General Requirement 1.1 Scope 3 1.2 Calibration Measurement Capability(CMC) 3 1.3 Personnel, Qualification and Training 3-4 1.4 Accommodation and Environmental Conditions 4-6 1.5 Special Requirements of Laboratory 6 1.6 Safety Precautions 6 1.7 Other Important Points 6 1.8 Proficiency Testing 6 2 Specific Requirements – Calibration – Liner Measurement 2.1 Scope 7-10 2.2 National/ International Standards, References and Guidelines 11 2.3 Metrological Requirements 13 2.4 Terms, Definitions and Application 14-15 2.5 Selection of Reference Standard 15-29 2.6 Calibration Interval 29 2.7 Legal Aspects 30 2.8 Environmental Condition 30 2.9 Calibration Methods 30 2.10 Calibration Procedure 30-34 2.11 Measurement Uncertainty 34 2.12 Evaluation of CMC 34 2.13 Sample Scope 36 2.14 Key Points 36 National Accreditation Board for Testing and Calibration Laboratories Doc.
    [Show full text]
  • MODULE 5 – Measuring Tools
    INTRODUCTION TO MACHINING 2. MEASURING TOOLS AND PROCESSES: In this chapter we will only look at those instruments which would typically be used during and at the end of a fabrication process. Such instruments would be capable of measuring up to 4 decimal places in the inch system and up to 3 decimal places in the metric system. Higher precision is normally not required in shop settings. The discrimination of a measuring instrument is the number of “segments” to which it divides the basic unit of length it is using for measurement. As a rule of thumb: the discrimination of the instrument should be ~10 times finer than the dimension specified. For example if a dimension of 25.5 [mm] is specified, an instrument that is capable of measuring to 0.01 or 0.02 [mm] should be used; if the specified dimension is 25.50 [mm], then the instrument’s discrimination should be 0.001 or 0.002 [mm]. The tools discussed here can be divided into 2 categories: direct measuring tools and indirect measuring or comparator tools. 50 INTRODUCTION TO MACHINING 2.1 Terminology: Accuracy: can have two meanings: it may describe the conformance of a specific dimension with the intended value (e.g.: an end-mill has a specific diameter stamped on its shank; if that value is confirmed by using the appropriate measuring device, then the end-mill diameter is said to be accurate). Accuracy may also refer to the act of measuring: if the machinist uses a steel rule to verify the diameter of the end-mill, then the act of measuring is not accurate.
    [Show full text]
  • *Tm 1-1500-204-23-9 Technical Manual Aviation Unit
    *TM 1-1500-204-23-9 TECHNICAL MANUAL AVIATION UNIT MAINTENANCE (AVUM) AND AVIATION INTERMEDIATE MAINTENANCE (AVIM) MANUAL FOR GENERAL AIRCRAFT MAINTENANCE (TOOLS AND GROUND SUPPORT EQUIPMENT) VOLUME 9 *This manual together with TM 1-1500-204-23-1 through TM 1-1500-204-23-8 and TM 1-1500- 204-23-10, dated 31 July 1992, supersedes TM 55-1500-204-25/1, dated 6 April 1970, including all changes. DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. HEADQUARTERS, DEPARTMENT OF THE ARMY 31 JULY 1992 This copy is a reprint which includes current pages from Changes 1 and 2. TM 1-1500-204-23-9 C4 CHANGE HEADQUARTERS DEPARTMENT OF THE ARMY NO. 4 WASHINGTON, D.C., 15 MARCH 2001 AVIATION UNIT MAINTENANCE (AVUM) AND AVIATION INTERMEDIATE MAINTENANCE (AVIM) MANUAL FOR GENERAL AIRCRAFT MAINTENANCE (TOOLS AND GROUND SUPPORT EQUIPMENT) VOLUME 9 Part Number National Stock Number 3800232-1-1 thru 1-3 2835-01-180-0452 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. TM 1-1500- 204-23-9, 31 July 1992, is changed as follows: 1. Remove and insert pages as indicated below. New or changed text material is indicated by a vertical bar in the margin. An illustration change is indicated by a miniature pointing hand. Remove pages Insert pages A / (B blank) A / (B blank) i / (ii blank) i / (ii blank) 7-11 through 7-15 7-11 through 7-15 7-16 blank 7-16 blank Index 13 and 14 Index 13 and 14 TM 1-1500-204-23-9 C4 2.Retain this sheet in front of manual for reference purposes.
    [Show full text]
  • Universal Length Measuring Machine SJ5100.Cdr
    1 SJ5100 Universal Length Measuring Machine Description Functions Thanks to precision glass-scale, precision guide rail and 1. Measure gauge blocks, thread gauges, plain gauges, Taper precision temperature compensation unit, cooperating with thread/plain gauges, pin gauge, caliper, spline gauges, setting different probes and workholders, SJ5100 achieves high- bars, snap gauges, internal/external micrometers, feeler gauges, precision measurement of various dimensional gauges. Dial indicators, dial bore gauge, dial test gauges, internal Moreover, because straightness of precision guide rail is every micrometer three points, etc. small, its repeatability is excellent by applying by bidirectional 2. Measure various gauges according to GB, ISO, BS, ANSI, constant measuring force technology. After the software records DIN, JIS, API standards. With comprehensive and professional the coordinates from precision glass-scale and introduces the standards in database, it meets requirements of most feedback data of measuring force device and temperature customers. sensor, the dimensional parameters are calculated according to 3. Conform to a variety of verification regulations & measuring the relevant definitions and formulas from selected norm. The standards. All test results are generated according to relevant whole measurement process can be completed in 3minutes. regulations and standards. 4. User-friendly software. 5.With centralized database management for measuring records, the operator can query and manage the measuring records according to object type , testing institution, manufacturing number, inspector, submitted institution, equipment number, inspection date and effective date. 6. Can print multiple selected test records or test certificates from database at once time. 7. Can export test data to Word, Excel, AutoCAD (optional) files. 8. Data backup and restore.
    [Show full text]
  • Quick Guide to Precision Measuring Instruments
    E4329 Quick Guide to Precision Measuring Instruments Coordinate Measuring Machines Vision Measuring Systems Form Measurement Optical Measuring Sensor Systems Test Equipment and Seismometers Digital Scale and DRO Systems Small Tool Instruments and Data Management Quick Guide to Precision Measuring Instruments Quick Guide to Precision Measuring Instruments 2 CONTENTS Meaning of Symbols 4 Conformance to CE Marking 5 Micrometers 6 Micrometer Heads 10 Internal Micrometers 14 Calipers 16 Height Gages 18 Dial Indicators/Dial Test Indicators 20 Gauge Blocks 24 Laser Scan Micrometers and Laser Indicators 26 Linear Gages 28 Linear Scales 30 Profile Projectors 32 Microscopes 34 Vision Measuring Machines 36 Surftest (Surface Roughness Testers) 38 Contracer (Contour Measuring Instruments) 40 Roundtest (Roundness Measuring Instruments) 42 Hardness Testing Machines 44 Vibration Measuring Instruments 46 Seismic Observation Equipment 48 Coordinate Measuring Machines 50 3 Quick Guide to Precision Measuring Instruments Quick Guide to Precision Measuring Instruments Meaning of Symbols ABSOLUTE Linear Encoder Mitutoyo's technology has realized the absolute position method (absolute method). With this method, you do not have to reset the system to zero after turning it off and then turning it on. The position information recorded on the scale is read every time. The following three types of absolute encoders are available: electrostatic capacitance model, electromagnetic induction model and model combining the electrostatic capacitance and optical methods. These encoders are widely used in a variety of measuring instruments as the length measuring system that can generate highly reliable measurement data. Advantages: 1. No count error occurs even if you move the slider or spindle extremely rapidly. 2. You do not have to reset the system to zero when turning on the system after turning it off*1.
    [Show full text]
  • Aircraft Materials, Processes, Cleaning and Corrosion Control (Course Outline), Aviation Mechanics 1(Power and Frame): 9073.01
    DOCUMENT RESUME .9 ,0) ED 092 687' CE 001 416 TITLE Aircraft Materials, Processes, Cleaning and Corrosion Control (Course Outline), Aviation Mechanics 1(Power and Frame): 9073.01. INSTITUTION Dade County Public Schools, Miami, Fla. PUB DATE 71 NOTE 31p.; An Authorized Course of Instruction for the Quinmester Program EDRS PRICE MF-$0.75 HC-$1.85 PLUS POSTAGE DESCRIPTORS *Aviation Mechanics; *Aviation Technology; Cleaning; Course Content; Course Objectives; *Curriculum Guides; *Equipment Maintenance; Job Skills; Machine Repairmen; Maintenance; Performance Criteria; *Technical Education IDENTIFIERS *Quinaester Program ABSTRACT This document presents an outline for a 135 -hour course designed to familiarize the beginning student with the basic concepts common to aircraft materials and processes, together with the requirements of prpper cleaning and corrosion control as outlined by the Federal Aviation Agency. Tbe aviation airframe and powerplant maintenance technician is expected to demonstratp his ability to explain the proper methods of cleaning the various components of an aircraft or engine, to prove his knowledge of nondesctactive testing methods, to inspect and check welds, to understand the basic heat-treatment processes and reasons for their use, to make precision measurements using various measuring instruments, and to indicate his knowledge of aircraft hardware and materials. The behavioral objectives and performance standards necessary for a person to become an airframe mechanic or powerplant mechanic, or to obtain a Federal Aviation Agency license are specified. An eight-item bibliography, a list of five films, and a Quinmester posttest sample are included. (KP) F AUTHORIZED COURSE OF INSTRUCTION FOR THE U 5 DEPARTMENT OF HEALTH. EDUCATION B WELFARE NATIONAL INSTITUTE OF EDUCATION DO .)MEN" FAA BEEN REPRO FrACTLY A5 PECE,,FD P;401,, E R',ON OR ORGAN,ZAT,ONOR,GIN ,O,NTS VIFV.
    [Show full text]
  • ANCA-ZOLLER Cooperation
    Cooperation ANCA | ZOLLER Tool inspection and data transfer 02 | 03 INTRODUCTION CONTENTS Introduction 02 ANCA | ZOLLER Since the company’s launch in 1974, ANCA has grown to become one of the world’s foremost CNC tool grinding machine manufacturers and has gained recognition in the industry as a leading technology innovator. ANCA’s progressive R&D program has ensured that ANCA remains at the cutting edge of global CNC grinder design and has resulted in the com- Specialists for inspection and measurement technology pany receiving numerous international industry and business awards. 04 Inspection and measurement technology – ZOLLER has the solutions 06 »pomBasic« and »pomBasicMicro« – the compact solution for universal tool inspection As ANCA designs and manufactures its own machines, the company is able to provide ingenious solutions for key components such as CNC 08 »smile / pilot 3.0« – for a professional start to the measurement of tools and grinding wheels controls, spindle and servo drives. ANCA manufacture all their own main mechanical components and assemblies, while also testing each final 10 »genius 3s« and »genius 3m« – the universal measuring machine for precision tools product to rigorous international machine tool standards. ANCA also develops its own advanced system and easy-to-use application software. 12 »threadCheck« – the universal measuring machine specifically for threaded tools 14 »titan« – the high-end inspection and measuring machine for all precision tools This unmatched level of autonomy and control allows ANCA
    [Show full text]