Single-Particle/Single-Cell Ion Microbeams As Probes of Biological Mechanisms Alan W

Total Page:16

File Type:pdf, Size:1020Kb

Single-Particle/Single-Cell Ion Microbeams As Probes of Biological Mechanisms Alan W 1424 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 36, NO. 4, AUGUST 2008 Single-Particle/Single-Cell Ion Microbeams as Probes of Biological Mechanisms Alan W. Bigelow, David J. Brenner, Guy Garty, and Gerhard Randers-Pehrson (Invited Paper) Abstract—An ion microbeam is a very narrow beam of charged-particle microbeams with subcellular resolution, where charged particles, typically protons, alpha particles, or heavier, the beam size is smaller than a cell nucleus. Coupled to an of micrometer/submicrometer size, corresponding to cellular/ endstation with imaging, location, and positioning techniques, subcellular dimensions. Together with integrated techniques for locating live cellular or subcellular targets, they allow rapid a microbeam is a powerful tool for controlled cell-irradiation sequential irradiation of these targets. This review covers both experiments. the technology involved in modern single-cell microbeams, as well Where cell-irradiation studies date back to studies in the as some current applications. The recent explosion of interest in 1950s [4], pioneers in the field of single-cell ion microbeam microbeams was initially driven by interest in the domestic radon irradiation include groups at Columbia University [5], the Gray problem, in which target cells are exposed either to zero or one alpha particle. Microbeams allow cells to be individually irradi- Cancer Institute (GCI) [6], [7], and the Pacific Northwest ated with exact numbers of particles. As microbeams were built, National Laboratory [8]. Since that time, the number of refined, and used, the biological questions that were addressed planned and operational microbeam facilities has significantly with them have considerably broadened, to encompass many increased. To provide a cohesive example of a microbeam aspects of damage signal transduction. Two areas in particular facility, this review article will first concentrate on the devel- have attracted much interest: One is the use of microbeams to address the sensitivity of subcellular targets, such as the cytoplasm opment of light ion microbeam technology at the Radiological or mitochondria. The other reflects the ability of the microbeam to Research Accelerator Facility (RARAF), Columbia University irradiate some cells, but not others, allowing a direct investigation and subsequently provide technical summaries of similar fa- of the so-called bystander effect, where signals from irradiated cilities. For a review on heavy ion microbeam facilities and cells can apparently cause biological responses in neighboring their applications, refer to the companion paper in this issue unirradiated cells. by Funayama et al. Index Terms—Accelerators, biological effects of radiation, imaging, particle beams. II. RARAF—A MICROBEAM FACILITY Microbeam technologies at RARAF are geared toward cell- I. INTRODUCTION irradiation experiments involving the bystander effect, genomic HAT HAPPENS to a mammalian cell, or a neighboring instability, and adaptive response. Researchers at RARAF W cell, when it is struck by ionizing radiation? This basic have developed a series of microbeam systems: Microbeam I, question has led to the development of single-particle single- Microbeam II, and the permanent magnetic microbeam (PMM), cell microbeam facilities for studying the biological effects of propagating those technical aspects that have proven useful particle irradiation. In order to study the effects of ionizing from one microbeam generation to the next. The following radiation on single cells, such as, the bystander effect [1], it overview of RARAF microbeams demonstrates merging novel is practical to have a device that can locate single-cell and concepts with successful established design. subcellular targets and deliver a prescribed specific dose [2] to each target. A minimum delivery of exactly one ion per cell A. Microbeam I nuclues demonstrates the precision of a single-particle single- cell ion microbeam and is particularly applicable to studying Initial microbeam development at RARAF was based on effects from radon exposure [3]. Particle accelerators with a vertical collimated beam from a model D1, 4.2-MV High specialized ion optics or collimators are capable of forming Voltage Engineering (HVE) Van de Graaff accelerator with a duoplasmatron ion source [5]. This particle accelerator, built in 1949, was originally the injector for the Cosmotron project Manuscript received November 10, 2007; revised February 6, 2008. This at Brookhaven National Laboratory and was moved to Nevis work was supported in part by the National Institute of Biomedical Imaging and Bioengineering under Grant NIBIB 5 P41 EB002033-12 and in part by the Laboratories in 1980, where it was used to pioneer single- National Cancer Institute under Grant 5P01-CA049062-16. cell single-particle microbeam studies at RARAF. The duoplas- The authors are with the Radiological Research Accelerator Facility, Center matron is a hot-cathode magnetic ion source, which typically for Radiological Research, Columbia University, Irvington, NY 10533 USA (e-mail: [email protected]). produces ions of hydrogen and helium isotopes [9]. In the Digital Object Identifier 10.1109/TPS.2008.927268 duoplasmatron design, an innovative electromagnet–electrode 0093-3813/$25.00 © 2008 IEEE BIGELOW et al.: SINGLE-PARTICLE/SINGLE-CELL ION MICROBEAMS AS PROBES OF BIOLOGICAL MECHANISMS 1425 combination forms plasma primarily at the exit hole of the ion of the scaler attached to the input of a high-voltage ampli- source [10]. fier (Technisches Büro S. Fischer, Ober-Ramstadt, Germany), The first-generation collimated microbeam at RARAF, now where the output drove electrostatic deflection plates to shutter decommissioned and referred to as Microbeam I, was ini- the ion beam. The shutter (stainless steel plates: 53.3-cm length, tially used for biology experiments starting in February 1994. 5.7-cm height, and 1.3-cm gap) was positioned approximately Apertures for beam collimation consisted of a 2-mm-diameter 6.4-m upstream from the exit window. aperture located 1.3 m before a final collimating pair of Several design aspects became RARAF standards since the apertures. The final consecutive collimating apertures were successful operation of Microbeam I. For one, a vertical ion 5- and 6-µm-diameter laser-drilled holes in 12.5-µm-thick beam for irradiation has a practical advantage when working stainless steel sheets, separated by 300 µm. The 6-µm-diameter with plated cells covered by a very thin nominally uniform aperture acted as an antiscatter element, to limit the particle layer of medium. Also, cell-dish transfer between the biologist irradiation to an area smaller than the nucleus of a human and the microbeam operator is expedited by having a biology cell. Nevertheless, a small fraction of the particles (8%) ar- workbench and incubator in the same room and adjacent to rived outside of the prescribed target region. This is a general the irradiator. For biology experiments, such as mutation and characteristic of all collimated microbeams and is overcome by oncogenic transformation studies [1], [3], [12]–[15], available using a focusing system. Two actuators were used to adjust high throughput of about 11 000 cells per hour was vital for the alignment of the final collimator, which was mounted in obtaining statistically relevant numbers of irradiated samples. a spherical gimbal. This decommissioned collimator assembly is currently located at the McMaster Accelerator Laboratory B. Microbeam II (McMaster University, Hamilton, ON, Canada) for microbeam development in that facility. The essential change from Microbeam I to Microbeam II Accurate cell imaging and targeting were facilitated through was to progress from a collimated beam to a focused ion a program written for real-time image analysis and stage po- beam on a dedicated beamline with a double-focusing magnet. sitioning. Developed in Visual Basic under the Windows NT The Microbeam II endstation incorporates a Nikon Eclipse operating system, the irradiation algorithm was essentially: 600FN microscope that rests in a kinetic mount and is also 1) with a low-magnification objective lens, acquire a series of attached to a pivot arm for online and offline positioning. adjacent images for coarse cellular location, and 2) under high Sample illumination is regulated with an adjustable light-guide- magnification, reimage each region that contains at least one coupled shuttered UV lamp. Ion beam scatter at the vacuum cell in the coarse image, then locate, position, and irradiate exit window is minimized by using a 100-nm-thick SiN exit cells. For each cell to be irradiated, a mechanical stage moves window. A precision xyz-stage incorporated into the endsta- the cell target to the coordinates of the ion beam, previously tion of Microbeam II comprises two components: a custom determined by imaging the profile of laser transmission through coarse xy-stage, designed and constructed in-house, coupled the final collimator. Tried and established on Microbeam I, this to a three-axis piezoelectric-actuated fine-motion stage, the control program has served as the base for further generations LP-200 low-profile nanopositioner from Mad City Laboratory of microbeam system development at RARAF. (Madison, WI) [16]. Each microbeam experiment includes an irradiation protocol A microbeam formed with focusing elements brought a with 1) a prescribed number of particles (as low as one) per promise of a smaller beam spot size, which matched the bio- targeted cell, 2) a percentage of cells to be targeted,
Recommended publications
  • 2021 V. 55 № 1/1 Special Issue the Organizers
    ISSN 0233-528X Aerospace and Environmental Medicine 2021 V. 55 № 1/1 special issue The Organizers: INTERNATIONAL ACADEMY OF ASTRONAUTICS (IAA) STATE SPACE CORPORATION “ROSCOSMOS” MINISTRY OF SCIENCE AND HIGHER EDUCATION OF THE RUSSIAN FEDERATION RUSSIAN ACADEMY OF SCIENCES (RAS) STATE RESEARCH CENTER OF THE RUSSIAN FEDERATION – INSTITUTE OF BIOMEDICAL PROBLEMS RAS Aerospace and Environmental Medicine AVIAKOSMICHESKAYA I EKOLOGICHESKAYA MEDITSINA SCIENTIFIC JOURNAL EDITOR-IN-CHIEF Orlov O.I., M.D., Academician of RAS EDITORIAL BOARD The Organizers: Ardashev V.N., M.D., professor Baranov V.M., M.D., professor, Academician of RAS Buravkova L.B., M.D., professor, Corresponding Member of RAS Bukhtiyarov I.V., M.D., professor Vinogradova O.L., Sci.D., professor – Deputy Editor D’yachenko A.I., Tech. D., professor Ivanov I.V., M.D., professor Ilyin E.A., M.D., professor Kotov O.V., Ph.D. Krasavin E.A., Ph.D., Sci.D., professor, Corresponding Member of RAS Medenkov A.A., Ph.D. in Psychology, M.D., professor Sinyak YU.E., M.D., Tech.D., professor Sorokin O.G., Ph.D. Suvorov A.V., M.D., professor Usov V.M., M.D., professor Homenko M.N., M.D., professor Mukai Ch., M.D., Ph.D. (Japan) Sutton J., M.D., Ph.D. (USA) Suchet L.G., Ph.D. (France) ADVISORY BOARD Grigoriev A.I., M.D., professor, Academician of RAS, Сhairman Blaginin A.A., M.D., Doctor of Psychology, professor Gal’chenko V.F., Sci.D., professor, Corresponding Member of RAS Zhdan’ko I.M., M.D. Ostrovskij M.A., Sci.D., professor, Academician of RAS Rozanov A.YU., D.Geol.Mineral.S., professor, Academician of RAS Rubin A.B., Sci.D., professor, Corresponding Member of RAS Zaluckij I.V., Sci.D., professor, Corresponding Member of NASB (Belarus) Kryshtal’ O.A., Sci.D., professor, Academician of NASU (Ukraine) Makashev E.K., D.Biol.Sci., professor, Corresponding Member of ASRK (Kazakhstan) Gerzer R., M.D., Ph.D., professor (Germany) Gharib C., Ph.D., professor (France) Yinghui Li, M.D., Ph.D., professor (China) 2021 V.
    [Show full text]
  • Testing the Stand-Alone Microbeam at Columbia University G
    Radiation Protection Dosimetry Advance Access published December 21, 2006 Radiation Protection Dosimetry (2006), 1 of 5 doi:10.1093/rpd/ncl454 TESTING THE STAND-ALONE MICROBEAM AT COLUMBIA UNIVERSITY G. GartyÃ, G. J. Ross, A. W. Bigelow, G. Randers-Pehrson and D. J. Brenner Columbia University, Radiological Research Accelerator Facility, 136 S. Broadway, Irvington, NY 10533, USA The stand-alone microbeam at Columbia University presents a novel approach to biological microbeam irradiation studies. Foregoing a conventional accelerator as a source of energetic ions, a small, high-specific-activity, alpha emitter is used. Alpha particles emitted from this source are focused using a compound magnetic lens consisting of 24 permanent magnets arranged in two quadrupole triplets. Using a ‘home made’ 6.5 mCi polonium source, a 1 alpha particle s–1,10lm diameter microbeam can, in principle, be realised. As the alpha source energy is constant, once the microbeam has been set up, no further adjustments are necessary apart from a periodic replacement of the source. The use of permanent magnets eliminates the need for bulky power supplies and cooling systems required by other types of ion lenses and greatly simplifies operation. It also makes the microbeam simple and cheap enough to be realised in any large lab. The Microbeam design as well as first tests of its performance, using an accelerator-based beam are presented here. INTRODUCTION AND OVERALL DESIGN the lenses. In addition to providing a secondary user facility at RARAF, the design is simple and Columbia University’s Radiological Research Accel- inexpensive enough that the SAM can be reproduced erator Facility (RARAF) currently offers its users in any large radiation biology laboratory.
    [Show full text]
  • Abstracts of Oral and Poster Presentations
    European Radiation Research 2004 The 33th Annual Meeting of the European Society for Radiation Biology Abstracts of Oral and Poster Presentations Guest Editor: Géza Sáfrány The abstracts published in this issue have not been peer-reviewed. Hence the opinions expressed in them are those of the authors and not necessarily those of the editor. The abstracts are in alphabetical order according to the first author. EUROPEAN RADIATION RESEARCH 2004, AUGUST 25–28, BUDAPEST, HUNGARY · 2004; 10: S5–S219 FACTORS INFLUENCING ON CLINICAL MANIFESTATION OF HCV IN GROUP OF CLEAN-UP WORKERS OF CHERNOBYL NPP ACCIDENT ABRAMENKO I. V., CHUMAK A. A., KOVALENKO A. N., BOYCHENKO P. K., AND PLESKACH O. Y. Research Centre for Radiation Medicine of Academy of Medical Sciences of Ukraine, Kyiv, Ukraine Imunological monitoring of 536 clean-up workers of Chornobyl NPP accident revealed significant prevalence of hepatitic C virus (HCV) infection (19.6%) compared with non- irratiated person (9.5%). Among 105 HCV carriers clinical signs of infection was found in 39 (37.41%) persons. Factors that influenced manifestation of HCV were male gender (r = 0.3553, p<0,0001), serological signs of previous hepatitic B virus (HBV) infection (r = 0.2896, p = 0.003), anti- bodies against cytomegalovirus (CMV) and T. gondii in serum (r = 0.3418, p<0.0001). –z Logistic regression (P = 1/1+e , where z = 1.5040 – 1.8405 × Mix(1) – 2.6026 × Mix(2) – 0.6567 × Mix(3); Mix(1) – serological signs of one of above menshioned infec- tions, Mix(2) – serological signs of two infections, and Mix(3) – serological signs of previous HBV, CMV and T.
    [Show full text]
  • Expanding the Question-Answering Potential of Single-Cell Microbeams at RARAF, USA
    J. Radiat. Res., 50: Suppl., A21-A28 (2009) Expanding the Question-answering Potential of Single-cell Microbeams at RARAF, USA Alan BIGELOW1,*, Guy GARTY1, Tomoo FUNAYAMA1,2, Gerhard RANDERS-PEHRSON1, David BRENNER1 and Charles GEARD1 Microbeam/Particle accelerator/Cell irradiation/Radiation biology. Charged-particle microbeams, developed to provide targeted irradiation of individual cells, and then of sub-cellular components, and then of 3-D tissues and now organisms, have been instrumental in chal- lenging and changing long accepted paradigms of radiation action. However the potential of these valuable tools can be enhanced by integrating additional components with the direct ability to measure biological responses in real time, or to manipulate the cell, tissue or organism of interest under conditions where information gained can be optimized. The RARAF microbeam has recently undergone an accelerator upgrade, and been modified to allow for multiple microbeam irradiation laboratories. Researchers with divergent interests have expressed desires for particular modalities to be made available and ongoing developments reflect these desires. The focus of this review is on the design, incorporation and use of mul- tiphoton and other imaging, micro-manipulation and single cell biosensor capabilities at RARAF. Addi- tionally, an update on the status of the other biology oriented microbeams in the Americas is provided. west National Laboratory,4) the Gray Cancer Institute,5,6) and INTRODUCTION Columbia University.7) Since that time, the number
    [Show full text]
  • Meeting Summary President's Cancer Panel
    MEETING SUMMARY PRESIDENT’S CANCER PANEL ENVIRONMENTAL FACTORS IN CANCER January 27, 2009 Phoenix, Arizona OVERVIEW This meeting was the last in the President’s Cancer Panel’s (PCP, the Panel) 2008/2009 series, Environmental Factors in Cancer. The meeting focused on radiation exposures as they relate to cancer risk. The agenda for the meeting was organized into three discussion panels. PARTICIPANTS President’s Cancer Panel LaSalle D. Leffall, Jr., M.D., F.A.C.S., Chair Margaret Kripke, Ph.D. National Cancer Institute (NCI), National Institutes of Health (NIH) Abby Sandler, Ph.D., Executive Secretary, PCP, NCI Beverly Laird, Ph.D., Vice-Chair, Director’s Consumer Liaison Group Panelists David J. Brenner, Ph.D., D.Sc., Director and Higgins Professor of Radiation Biophysics, Center for Radiological Research, Columbia University Medical Center David O. Carpenter, M.D., Director, Institute for Health and Environment, University at Albany School of Public Health Thomas H. Essig, M.S., Rehired Annuitant, Office of Federal and State Materials and Environmental Management Programs, U.S. Nuclear Regulatory Commission (NRC) Michael Lerner, Ph.D., President and Founder, Commonweal Martha S. Linet, M.D., M.P.H., Chief and Senior Investigator, Radiation Epidemiology Branch, National Cancer Institute Mahadevappa Mahesh, Ph.D., M.S., Associate Professor of Radiology and Cardiology, Johns Hopkins University School of Medicine Fred A. Mettler, M.D., M.P.H., Professor Emeritus, Department of Radiology, New Mexico VA Healthcare System Neal A. Palafox, M.D., M.P.H., Professor and Chair, Family Medicine and Community Health, John A. Burns School of Medicine, University of Hawai’i at Manoa Trisha Thompson Pritikin, Esq., M.Ed., Hanford Downwinder, Berkeley, CA Jonathan Samet, M.D., M.S., Professor and Chair, Department of Preventive Medicine, University of Southern California (USC)/Norris Comprehensive Cancer Center William A.
    [Show full text]
  • UV Microspot Irradiator at Columbia University
    Radiat Environ Biophys (2013) 52:411–417 DOI 10.1007/s00411-013-0474-9 SHORT COMMUNICATION UV microspot irradiator at Columbia University Alan W. Bigelow • Brian Ponnaiya • Kimara L. Targoff • David J. Brenner Received: 8 February 2013 / Accepted: 13 May 2013 / Published online: 26 May 2013 Ó Springer-Verlag Berlin Heidelberg 2013 Abstract The Radiological Research Accelerator Facility Accelerator Facility (RARAF), Columbia University at Columbia University has recently added a UV microspot (Bigelow et al. 2011). While ion beams from the HVE irradiator to a microbeam irradiation platform. This UV 5.5 MeV Singletron particle accelerator at the facility also microspot irradiator applies multiphoton excitation at the support secondary X-ray and neutron microbeam develop- focal point of an incident laser as the source for cell ments (Harken et al. 2011; Xu et al. 2011), a UV microspot damage, and with this approach, a single cell within a 3D irradiator is now combined with a charged-particle micro- sample can be targeted and exposed to damaging UV. The beam irradiator to enable experiments that require both UV microspot’s ability to impart cellular damage within photon and particle irradiations on the same platform. In 3D is an advantage over all other microbeam techniques, contrast to cellular damage along the particle tracks from which instead impart damage to numerous cells along charged-particle microbeam irradiators, the UV microspot microbeam tracks. This short communication is an over- delivers damage through multiphoton excitation at localized view, and a description of the UV microspot including the cellular regions within a 3D sample. This integrated design following applications and demonstrations of selective allows the UV microspot to operate in two modes: (1) as a damage to live single cell targets: DNA damage foci for- stand-alone UV microspot irradiator and (2) as a probe to mation, patterned irradiation, photoactivation, targeting of work in concert with ion-beam irradiation experiments.
    [Show full text]
  • Progress at LAMPF Los Alamos National Laboratory Los Alamos
    LA-9256-PR Progress Report UC-28 LA—9256-PR Issued: March 1M2 DE82 013753 Progress at LAMPF July—December 1981 Clinton P. Anderson Meson Physics Facility Editor John C. Allred Scientific Editorial Board Olin B. van Dyck Richard L. Hutson M. Stanley Livingston Mario E. Schillaci Production Staff Kit Ruminer Beverly H. Talley so'eij t>y an agency o' the United Slates Govetnin Nether th.. tJf-HW S-dt« Govf.tr •nrv ihetijol. nor .iny a( The,r employees, 'mln, warrjnl/. cuproK <j- implioi], ni k-gjl liability Of responsibility for irifc iitturacy. cumuli.innnit, 01 utnlulnr.'ss o- "*, uaiwutus. product, ar proctm niscloy.tj. or lily owned rights. Reference herein to any specific eomitvciai u'liduct. o-owtt. ii- y name, trademark, mjiufncturei. or oihcr«i*\ does J not nereswrrv- constitute or .nc it'll. tciOTimciidalinn, or favoring By tha U.nfed f necessir-iiy state w ipdeci those of i r*ii'<i Sta es Govofnmeni 01 V agency thereof. ABSTRACT Progress at LAMPF is the semiannual progress report of the MP Division of the Los Alamos National Laboratory. The report includes brief reports on research done at LAMPF by researchers from other institutions and Los Alamos divisions. Los Alamos National Laboratory Mmm Los Alamos, New Mexico 87545 WSTJBBI/r/ow lyj^mm,* Time to Think about the Future: LAMPF continues to increase its capabilities and productivity. Experimenters are asking ever more sharply defined questions and experiments are becoming increasingly illuminating. The rate of accomplishment is high, but strongly limited by budgets for research and operations.
    [Show full text]
  • Development of a Robotically-Based Automated Biodosimetry Tool for High-Throughput Radiological Triage
    Int. J. Biomechatronics and Biomedical Robotics, Vol. 1, No. 2, 2010 115 Development of a robotically-based automated biodosimetry tool for high-throughput radiological triage Youhua Chen*, Jian Zhang, Hongliang Wang, Nabil Simaan and Y. Lawrence Yao Columbia University, 220 S.W. Mudd Building, 500 West 120th Street, New York, NY 10027 USA E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] *Corresponding author Guy Garty, Yanping Xu, Oleksandra V. Lyulko, Helen C. Turner, Gerhard Randers-Pehrson and D.J. Brenner Columbia University, 136 S. Broadway, Irvington, NY 10533 USA E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] Abstract: To provide the best opportunities for life-saving interventions in the event of a radiological or nuclear threat, there is an urgent need to improve the speed and efficiency of biodosimetric assays for triage and therapy. A rapid automated biodosimetric system used to assess thousands of individual radiation exposure doses is helpful to curb mass panic, and to conserve limited medical resources. This paper presents the development of a new robotically-based automated biodosimetry tool (RABiT). The RABiT is capable of automating two mature biodosimetry assays: the micronucleus and γ-H2AX assay. The design considerations guiding the hardware and software architecture are presented with focus on ease of implementation, methods of communication and need for real-time control versus soft time control cycles.
    [Show full text]
  • Ion, Xray, UV and Neutron Microbeam Systems for Cell Irradiation A
    Ion, XRay, UV And Neutron Microbeam Systems For Cell Irradiation A. W. Bigelow, G. RandersPehrson, G. Garty, C. R. Geard, Y. Xu et al. Citation: AIP Conf. Proc. 1336, 351 (2011); doi: 10.1063/1.3586118 View online: http://dx.doi.org/10.1063/1.3586118 View Table of Contents: http://proceedings.aip.org/dbt/dbt.jsp?KEY=APCPCS&Volume=1336&Issue=1 Published by the American Institute of Physics. Related Articles Design and specifications of the diagnostics for the instrumented calorimeter of Source for the Production of Ions of Deuterium Extracted from Radio frequency plasma Rev. Sci. Instrum. 83, 02B724 (2012) Charge breeding results and future prospects with electron cyclotron resonance ion source and electron beam ion source (invited) Rev. Sci. Instrum. 83, 02A913 (2012) The on-line charge breeding program at TRIUMF's Ion Trap For Atomic and Nuclear Science for precision mass measurements Rev. Sci. Instrum. 83, 02A912 (2012) Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP Rev. Sci. Instrum. 83, 02A335 (2012) First commissioning results with the Grenoble test electron cyclotron resonance ion source at iThemba LABS Rev. Sci. Instrum. 83, 02A323 (2012) Additional information on AIP Conf. Proc. Journal Homepage: http://proceedings.aip.org/ Journal Information: http://proceedings.aip.org/about/about_the_proceedings Top downloads: http://proceedings.aip.org/dbt/most_downloaded.jsp?KEY=APCPCS Information for Authors: http://proceedings.aip.org/authors/information_for_authors Downloaded 19 Mar 2012 to 129.236.252.4. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/about/rights_permissions Ion, X-Ray, UV And Neutron Microbeam Systems For Cell Irradiation A.W.
    [Show full text]
  • Developing a Long-Term Strategy for Low-Dose Radiation Research in the United States MEETING #2 (Virtual) August 26, 2021
    Developing a Long-Term Strategy for Low-Dose Radiation Research in the United States MEETING #2 (Virtual) August 26, 2021, All times are EDT PUBLIC AGENDA SESSION 1 – OPEN TO THE PUBLIC ZOOM CONNECTION https://nasem.zoom.us/j/96270123233?pwd=ekVnb1lTSnpCRWthQ0JhWmVNK3kvZz09 Password: 491085 11:00 AM – 11:05 AM Welcome and Open Public Session Joe Gray, Committee Chair 11:05 PM – 11:25 PM Comments from Congress on the Request for the Study Alyse Huffman and Adam Rosenberg, Committee on Science, Space, and Technology, Energy Subcommittee, U.S. House of Representatives • Motivation for the study request and regulations in need of better understanding of low-dose risks. • Clarification on charge 7 of the statement of task—what is Congress’s intention? • Views on high priority research. • Views on DOE’s low-dose research activities for FY2021 and expectations for FY2022. • Metrics of success for the low-dose program. • Views on sustainability of funding for the low-dose program; what happens past FY2024? 11:25 PM – 11:45 PM Q+A with the Committee and Staff Moderated by Joe Gray, Committee Chair 11:45 PM – 12:05 PM Perspectives from the Interagency Steering Committee on Radiation Standards (ISCORS) Mike Boyd, Environmental Protection Agency; Vince Holahan, U.S. Nuclear Regulatory Commission • Introduce ISCORS, role, and membership. • Regulations that could be better informed by improved understanding of low-dose risks. Nuclear and Radiation Studies Board 500 Fifth Street, NW, Washington, DC 20001 Phone 202.334.3066 Fax 202.334.3077 www.nationalacademies.org • Process for changing regulations in light of new scientific evidence and coordination across agencies.
    [Show full text]
  • The Radiological Research Accelerator Facility (RARAF)
    THE RADIOLOGICAL RESEARCH ACCELERATOR FACILITY The Radiological Research Accelerator Facility (RARAF) Page⏐ 133 CENTER FOR RADIOLOGICAL RESEARCH • ANNUAL REPORT 2015 THE RADIOLOGICAL RESEARCH ACCELERATOR FACILITY An NIH-Supported Resource Center WWW.RARAF.ORG Director: David J. Brenner, Ph.D., D.Sc. Associate Director: Gerhard Randers-Pehrson, Ph.D. RESEARCH USING RARAF experiments starting to use the Microbeam Facility to examine damage to sub-cellular structures (e.g., The “bystander” effect - the response of cells that are mitochondria, telomeres, and specific chromosomes) and not directly irradiated but are in close contact with, other radiation effects. Research into bystander effects in nearby, or only in the presence of irradiated cells, has vivo continued this past year with irradiations of the ears been the focus for many of the biological studies at of mice. RARAF over the past two decades. Both the Microbeam and the Track Segment Facilities continue to be utilized in Experiments various investigations of this response to radiation Listed in Table 1 are the experiments performed using exposure. This year the number of biological experiments the RARAF Singletron between January 1 and December investigating the mechanism(s) by which the effect is 31, 2015, and the number of shifts each was run in this transmitted has declined somewhat, with newer period. Fractional shifts are assigned when experimental Table 1. Experiments Run at RARAF January 1 - December 31, 2015 Exp Exp. Shifts No. Experimenter Institution Type Title of Experiment
    [Show full text]
  • Metabolic Oxygen Consumption Measurement with a Single-Cell.Pdf
    Radiat Environ Biophys (2015) 54:137–144 DOI 10.1007/s00411-014-0574-1 SHORT COMMUNICATION Metabolic oxygen consumption measurement with a single-cell biosensor after particle microbeam irradiation Yanping Xu • Bo Zhang • Mark Messerli • Gerhard Randers-Pehrson • Tom K. Hei • David J. Brenner Received: 19 March 2014 / Accepted: 9 October 2014 / Published online: 22 October 2014 Ó Springer-Verlag Berlin Heidelberg 2014 Abstract A noninvasive, self-referencing biosensor/probe They established cell nuclear and cytoplasmic responses of system has been integrated into the Columbia University targeted cells, along with responses of nontargeted bystander Radiological Research Accelerator Facility Microbeam II cells (Hei et al. 2009). There is evidence that radiation- end station. A single-cell oxygen consumption measurement induced bystander signals between cells may originate with a has been conducted with this type of oxygen probe in 37° C diffusible mediator (Shao et al. 2002; Matsumoto et al. 2001; Krebs–Ringer Bicarbonate buffer immediately before and Azzam et al. 2002). To physically demonstrate the radiation- after a single-cell microbeam irradiation. It is the first such induced oxygen flux changes outside the irradiated cell, a measurement made for a microbeam irradiation, and a six self-referencing amperometric electrochemical sensor was fold increment of oxygen flux induced during a 15-s period of proposed for use with single-cell irradiation experiment. time has been observed following radiation exposure. The This type of micro-biosensor allows sensitive and noninva- experimental procedure and the results are discussed. sive measurement of the flux of radical mediators, such as oxygen (or nitric oxide), in single cells.
    [Show full text]