VWR® Laboratory Equipment Table of Contents Table of Contents

Total Page:16

File Type:pdf, Size:1020Kb

VWR® Laboratory Equipment Table of Contents Table of Contents VWR® Laboratory Equipment Table of Contents TABLE OF CONTENTS Table of Contents 2-43 Shakers 74 Heavy-Duty Vortex Mixers 3 Thermal Shake Touch 76 Vortex Mixers 10 Open-Air Shakers 80 Multi-Tube Vortexers 25 Incubating Shakers 83-85 Homogenizers 36 Platforms 86-112 Clamps 40 Flask Clamps 87 Multi-Purpose 42 Test Tube Racks 91 Specialty 44-63 Hotplates / Stirrers 97 Connectors & Holders 46 Professional Hotplates, Stirrers, and Hotplate-Stirrers 101 Lab-Frames 48 Advanced Hotplates, Stirrers, and Hotplate-Stirrers 104 Support Stands 50 Standard Hotplates, Stirrers, and Hotplate-Stirrers 107 Gas Cylinder Safety Supports 52 Round Top Hotplate-Stirrers 110 Lab-Lifts 55 Basic Mini Hotplates, Stirrers, and Hotplate-Stirrers 112 Flow Control 56 Specialty Stirrers 113-116 Miscellaneous 63 Supports 113 Other Quality Products 64-72 Dry Block Heaters 114 Microplate Stability Chamber 73-82 Vortex Mixers 115 VWR Opti-Flow Forced Ventilation System 73 Microplate Vortex Mixers 116 Custom Manufacturing & Engineering 1 VWR® SHAKERS VWR® SHAKERS The new VWR® family of laboratory shakers has one of the industry’s largest offerings on the market today, covering a wide range of applications. Many shakers are available as incubating, cooling, or open air and with orbital, reciprocating, rocking, or waving motions. Capacities range from one microplate up to 150lbs (68.1kg). • VWR® introduces ALL NEW TOUCH SCREEN TECHNOLOGY • 2 new models; the VWR® Thermal Shake Touch and the VWR® Cooling Thermal Shake Touch...operating a shaker this sophisticated has never been easier. • Touch screen technology • On board help screens available on almost every screen • Programmable for up to 5 separate, 5-step programs or unlimited if using USB • Small footprint • Rapid heating and cooling with high speed shaking • Programmable in 6 different languages • Patented design features • Exceptional 5 year warranty on all models • Advanced electronics • Safety features • Calibration modes • Interfacing • Easy to use controls • Expanded line of accessories to fit almost any application • Platforms (available in a variety of sizes): • Universal - lets you easily mount flask clamps and test tube racks • Dedicated - pre-mounted flask clamps of the same size, maximizes the capacity of your platform • Adjustable - uses roller bars allowing the most flexibility in securing your vessels • Culture- ideal for slow speed applications utilizing low profile, flat bottom vessels • Large Vessel Carrier - utilizes high sides and a heavy-duty design to help secure oversized vessels • Separatory Funnel - holds three 500mL to 2L funnels • Clamps • Erlenmeyer • Media bottles • Microplates • Test Tube Racks • Pivoting • Fixed position 2 VWR® SHAKERS VWR® SHAKERS VWR® Thermal Shake Touch • Intuitive 4.3” color LCD touch screen • Ability for rapid heating and high speed shaking • Internal memory stores five separate 5-step programs • Supplied with 1.5mL block The VWR® Thermal Shake Touch is designed for applications that require consistent and precise results. With heating and shaking capabilities, the VWR® Thermal Shake Touch uses interchangeable blocks to accommodate a wide variety of tubes and microplates. The easy-to-use 4.3” color LCD touch screen allows the user to save and visibly track progress through the live status bar for five user defined programs, each with five individual steps. The unit’s enhanced electronics and temperature sensor provide accurate, dependable temperature settings across the operating range. Operating Features: Low profile design: The low profile design minimizes the unit’s footprint on the bench. 89232-908 LCD touch screen: Enables faster setting of temperature, speed and time, which can all be viewed at once. Display features on-screen help topics with operational tips available in six languages. Touch screen is compatible with rubber gloves used in labs. Ordering Information USB port can transfer information to a flash drive for data logging, program storage Unit includes a 92” (234cm) detachable, 3-wire cord and plug (230 volt units are and software updates. supplied with Euro type plug). Unit is also supplied with a 1.5mL block, clear rack and Program control: Program control capabilities allow user programmable operation for cover. 5 year limited warranty on parts and labor. Eppendorf® Thermomixer R® blocks automated use and memory. Storage for five separate 5-step programs, or unlimited are compatible on the VWR® Thermal Shake Touch. number of programs with the use of the USB. Optional NIST Traceable Calibration Certificate provided by an ISO/IEC 17025 Temperature ramp rate: Adjustable temperature ramp rate feature separately defines accredited laboratory. Multiple data points within the temperature and speed ranges, the heating rate in increments of 0.5°C/min. and time function, are reported on the certificate with the associated uncertainties. Single point calibration mode: For maximum temperature accuracy, the single point calibration procedure allows the user to calibrate up to 6 different user defined Specifications temperatures. Temperature Range 4°C above ambient to 100°C Pulse mode feature: The unit is equipped with a pulse mode feature ideal for quick Temperature Accuracy ± 1°C between 20°C and 45°C vortex applications. ± 2°C above 45°C Safety Features: Speed Range 300 to 3000rpm Cool touch housing: Constructed from a high-quality heat and chemical resistant Speed Accuracy ± 2% polymer. The unit’s housing remains cool to the touch throughout normal operating Timer 1 minute to 99 hours, 59 minutes temperatures. Orbit 3mm (0.12”) Maximum temperature limiting function: Ensures the temperature will not exceed user defined limits, allowing the user control of temperature sensitive samples. Heating Rate 5°C/minute Hot top indicator: A hot top warning light will illuminate when the temperature reaches Overall Dimensions (L x W x H) 10.25 x 9.75 x 5.2” (26 x 24.8 x 13.2cm) 40°C and will remain lit until the unit is sufficiently cooled. Ship Weight 17lbs (7.7kg) Audible alarm: In timed mode, an alarm will sound when the time reaches zero or set-point temperature is reached. Additionally, the heat function will automatically shut off if the unit recognizes an internal issue. Operating Conditions: Unit can operate in conditions from 5 to 35°C (41 to 95°F), maximum 80% relative humidity, non-condensing. Applications: Cell cultures, DNA, RNA, hybridization, and protein studies. VWR® Thermal Shake Touch Description Electrical (50/60 Hz) Cat. No. Thermal Shake Touch 120V | 1.8 amps | 215 watts 89232-908 Thermal Shake Touch 230V | 0.9 amps | 210 watts 89232-910 Thermal Shake Touch with NIST Traceable Certificate 120V | 1.8 amps | 215 watts 10027-174 Thermal Shake Touch with NIST Traceable Certificate 230V | 0.9 amps | 210 watts 10027-176 3 VWR® SHAKERS VWR® SHAKERS VWR® Cooling Thermal Shake Touch • Intuitive 4.3” color LCD touch screen • Ability for rapid heating, cooling and high speed shaking • Internal memory stores five separate 5-step programs • Supplied with 1.5mL block The VWR® Cooling Thermal Shake Touch is designed for applications that require consistent and precise results. With heating, cooling and shaking capabilities, the VWR® Cooling Thermal Shake Touch uses interchangeable blocks to accommodate a wide variety of tubes and microplates. The easy-to-use 4.3” color LCD touch screen allows the user to save and visibly track progress through the live status bar for five user defined programs, each with five individual steps. The unit’s enhanced electronics and dual temperature sensors provide accurate, dependable temperature settings across the operating range. Operating Features: Low profile design: The low profile design minimizes the unit’s footprint on the bench. 89232-904 LCD touch screen: Enables faster setting of temperature, speed and time, which can all be viewed at once. Display features on-screen help topics with operational tips available in six languages. Touch screen is compatible with rubber gloves used in labs. Ordering Information USB port can transfer information to a flash drive for data logging, program storage and Unit includes a 92” (234cm) detachable, 3-wire cord and plug (230 volt units are supplied software updates. with Euro type plug). Unit is also supplied with a 1.5mL block, a rack and a cover. 5 year Program control: Program control capabilities allow user programmable operation for limited warranty on parts and labor. Eppendorf® Thermomixer R® blocks are compatible automated use and memory. Storage for five separate 5-step programs, or unlimited on the VWR® Cooling Thermal Shake Touch. number of programs with the use of the USB. Optional NIST Traceable Calibration Certificate provided by an ISO/IEC 17025 Temperature ramp rate: Adjustable temperature ramp rate feature separately defines accredited laboratory. Multiple data points within the temperature and speed ranges, the heating and cooling rates in increments of 0.5°C/min. and time function, are reported on the certificate with the associated uncertainties. Single point calibration mode: For maximum temperature accuracy, the single point calibration procedure allows the user to calibrate up to 6 different defined temperatures. Specifications Pulse mode feature: The unit is equipped with a pulse mode feature ideal for quick Temperature Range 17°C below ambient to 100°C vortex applications. Temperature Accuracy ± 0.5°C between 20°C and 45°C Safety Features: ± 2°C below 20°C and above 45°C Speed Range 300 to 3000rpm Cool touch housing: Constructed from a high-quality
Recommended publications
  • The Magic Motion
    The Magic Motion www.wiggens.com Rotary Evaporators Pumps Stirrers Heating Shakers Homogenizers Incubators Gas Generators About WIGGENS Wiggens was established in 2005 with the goal delivering the best laboratory equipment and service for reliable results, since then Wiggens has been producing top-quality general laboratory equipment, our brand Wiggens stands for high quality, durability and remarkable performance. Wiggens is your general laboratory companion and provides products that can be used in all kinds of laboratory environments. The Wiggens product range entails an extensive range of magnetic stirrers, heating mantles and dry baths. Advanced infrared hot plates with integrated stirring functions for an even heat distribution among your solvents are also available, in addition Wiggens also provides overhead stirrers with diverse characteristics to perfectly match the laboratory stirring and blending requirements. A complete range of new products in 2017 including homogenizers of different magnitudes as well as a broad range of shakers, multi-purpose heaters, colony counters. incubators, ovens and shaking incubators for full temperature control. ChemVak is your brand specializing in vacuum technology offering an extensive range of vacuum pumps for all applications, including chemical-resistant diaphragm pumps and oil-free piston pumps, are complemented by vacuum filtration equipment for a wide range of different applications. In addition, water-jet aspirator pumps and bio-suction systems are part of the product range. In 2017, Wiggens launched its whole range gas generators with Vgas product band, the new Vgas product line rounds out our product solutions as a specialist in vacuum and gas related operations. ChemTron is your brand for chemical reaction solutions, Biotron for highly qualified bio-equipment and Vdose specialized in liquid handling pumps, completes the range of brands within the Wiggens family.
    [Show full text]
  • Freezing and Boiling Point Changes
    Freezing Point and Boiling Point Changes for Solutions and Solids Lesson Plans and Labs By Ranald Bleakley Physics and Chemistry teacher Weedsport Jnr/Snr High School RET 2 Cornell Center for Materials Research Summer 2005 Freezing Point and Boiling Point Changes for Solutions and Solids Lesson Plans and Labs Summary: Major skills taught: • Predicting changes in freezing and boiling points of water, given type and quantity of solute added. • Solving word problems for changes to boiling points and freezing points of solutions based upon data supplied. • Application of theory to real samples in lab to collect and analyze data. Students will describe the importance to industry of the depression of melting points in solids such as metals and glasses. • Students will describe and discuss the evolution of glass making through the ages and its influence on social evolution. Appropriate grade and level: The following lesson plans and labs are intended for instruction of juniors or seniors enrolled in introductory chemistry and/or physics classes. It is most appropriately taught to students who have a basic understanding of the properties of matter and of solutions. Mathematical calculations are intentionally kept to a minimum in this unit and focus is placed on concepts. The overall intent of the unit is to clarify the relationship between changes to the composition of a mixture and the subsequent changes in the eutectic properties of that mixture. Theme: The lesson plans and labs contained in this unit seek to teach and illustrate the concepts associated with the eutectic of both liquid solutions, and glasses The following people have been of great assistance: Professor Louis Hand Professor of Physics.
    [Show full text]
  • Lab Equipment Do More with OHAUS
    Lab Equipment Do More With OHAUS Contents Centrifuges Frontier™ Series ...........................................................................................................................1 Rotors & Accessories .................................................................................................................6 Open Air Shakers Light Duty Orbital Shakers ....................................................................................................25 Extreme Environment Shakers ............................................................................................26 Heavy Duty Orbital Shakers ..................................................................................................27 Rocking & Waving Shakers ....................................................................................................30 Reciprocating Shakers ............................................................................................................32 Incubating & Incubating Cooling Shakers Cooling Thermal Shakers .......................................................................................................33 Light Duty Orbital Shakers ....................................................................................................36 Cooling Orbital Shakers .........................................................................................................37 Rocking & Waving Shakers ....................................................................................................40 Shakers Accessories
    [Show full text]
  • Procedures Manual
    PROCEDURES MANUAL Created: 02/1992 Revised: 06/1992, 11/1993, 06/1994, 10/1994, 10/1996, 10/1999, 10/2000, 06/2007, 05/2008, 11/2008, 06/2009, 06/2010, 07/2011, 06/2012, 11/2012, 06/2013, 06/2014, 06/2015, 06/2016, 06/2017 1 EBAA Procedures Manual –June 2017 TABLE OF CONTENTS A1.000 Introduction and Purpose ..................................................................................................................... 4 B1.000 Active Membership and Accreditation .................................................................................................. 5 C2.000 Training, Certification, and Continuing Education of Personnel Performing Tasks Overseen and/or Regulated by the EBAA, FDA, and Other State/Federal Agencies .................................................... 6 C3.000 Facilities ................................................................................................................................................. 8 C3.100 Eye Bank Laboratory ............................................................................................................... 8 C3.200 Equipment, Maintenance and Cleaning .................................................................................. 9 C3.300 Instruments, Cleaning and Maintenance ............................................................................. 13 C3.400 Procedures Manual ............................................................................................................... 15 C3.600 Infection Control and Personnel Safety ..............................................................................
    [Show full text]
  • Effluent-Monitoring Procedures: Basic Laboratory Skills. Student
    I 1 ' DOCU 4ENT. RESUME 0 ED-147 193 SF 023 381 AUTHOR Engel,. William II;.; And Others TITLE Effluent - Monitoring Procedures: Basic Laboratory Skillt. Student NiTtrence tanual., ,INSTITUTJO Environmental ProtectiOrt Agency; Washington, D.C. : Office of Water Programs. REPORT NO EPA-430-1-77-011 PUB DATE' Oct 77 , 40 NOTE 182p.: forrelated documents; see SE 023 177-34'3 EDRS pRicp 111.40.83 C-$10.03 Plus Postage. DESCRIRTORS 0 Chemistry; Enviionmental Edlicrition; *Instructional:- paterials; *Laboratory Equipment; *Laboratory ,Techniques; Microbiology; *Pollution; Tost Secondary 'Education; Skill Development; *Water Pollution Control IDENTIFIERS *Waste hater Treatment ABSTRACT . This%is one of several shoit-ter courseq developed to'assist in the training of waste water treatment plant operational personnel in the tests, measurements,. and report trepairation required for compliance with their NPDES Permits. This Student Reference Manual provides a review of basid mathematics as it applies to the chemical laboratory, The uge of equipment and solution preparation are- stressed. Additionally, a nodule on basic micrObiologicai, techniques is included. EaCh lesson outlines ,a specific objective, description of the aealysis, and the applicatility,of the procedure. Included in this document, are materials related to determining dissolved oxygen, ph, fecal coliform, water flow, suspended 'solid's, and Chlorine., (CS) IL . .. * Documents acquired by.ERIC include many informal unpuillithed * * materials not available from other sources. ERIC sates evety effort *. * to' obtain the liest,popy available. Nivertheleseeitems of marginal''' * * reproducibility are ofteh encountered and'thit affectt the quality * * of the micOfiche and hardco6 reproductions ERIC lakes available *. * via tht ERIC Docnment Reproduction Service (EDRS). ups is not '*; * responsible for the quality of the original, doeument:Reproductions * * supirplied by EDRS.
    [Show full text]
  • Super-Resolution Imaging of the Natural Killer Cell Immunological Synapse on a Glass-Supported Planar Lipid Bilayer
    Journal of Visualized Experiments www.jove.com Video Article Super-resolution Imaging of the Natural Killer Cell Immunological Synapse on a Glass-supported Planar Lipid Bilayer Peilin Zheng*1,2, Grant Bertolet*1,2,3, Yuhui Chen1,2, Shengjian Huang1,2, Dongfang Liu1,2,3 1 Center for Human Immunobiology, Texas Children's Hospital 2 Department of Pediatrics, Baylor College of Medicine 3 Department of Pathology and Immunology, Baylor College of Medicine * These authors contributed equally Correspondence to: Dongfang Liu at [email protected] URL: https://www.jove.com/video/52502 DOI: doi:10.3791/52502 Keywords: Immunology, Issue 96, Natural killer cells, immunological synapse, imaging, STED, supported lipid bilayer, super-resolution Date Published: 2/11/2015 Citation: Zheng, P., Bertolet, G., Chen, Y., Huang, S., Liu, D. Super-resolution Imaging of the Natural Killer Cell Immunological Synapse on a Glass- supported Planar Lipid Bilayer. J. Vis. Exp. (96), e52502, doi:10.3791/52502 (2015). Abstract The glass-supported planar lipid bilayer system has been utilized in a variety of disciplines. One of the most useful applications of this technique has been in the study of immunological synapse formation, due to the ability of the glass-supported planar lipid bilayers to mimic the surface of a target cell while forming a horizontal interface. The recent advances in super-resolution imaging have further allowed scientists to better view the fine details of synapse structure. In this study, one of these advanced techniques, stimulated emission depletion (STED), is utilized to study the structure of natural killer (NK) cell synapses on the supported lipid bilayer.
    [Show full text]
  • Laboratory Equipment Used in Filtration
    KNOW YOUR LAB EQUIPMENTS Test tube A test tube, also known as a sample tube, is a common piece of laboratory glassware consisting of a finger-like length of glass or clear plastic tubing, open at the top and closed at the bottom. Beakers Beakers are used as containers. They are available in a variety of sizes. Although they often possess volume markings, these are only rough estimates of the liquid volume. The markings are not necessarily accurate. Erlenmeyer flask Erlenmeyer flasks are often used as reaction vessels, particularly in titrations. As with beakers, the volume markings should not be considered accurate. Volumetric flask Volumetric flasks are used to measure and store solutions with a high degree of accuracy. These flasks generally possess a marking near the top that indicates the level at which the volume of the liquid is equal to the volume written on the outside of the flask. These devices are often used when solutions containing dissolved solids of known concentration are needed. Graduated cylinder Graduated cylinders are used to transfer liquids with a moderate degree of accuracy. Pipette Pipettes are used for transferring liquids with a fixed volume and quantity of liquid must be known to a high degree of accuracy. Graduated pipette These Pipettes are calibrated in the factory to release the desired quantity of liquid. Disposable pipette Disposable transfer. These Pipettes are made of plastic and are useful for transferring liquids dropwise. Burette Burettes are devices used typically in analytical, quantitative chemistry applications for measuring liquid solution. Differing from a pipette since the sample quantity delivered is changeable, graduated Burettes are used heavily in titration experiments.
    [Show full text]
  • Appendix A: Laboratory Standard
    U.S. Army Corps of Engineers New England District Concord, Massachusetts QUALITY ASSURANCE PROJECT PLAN Volume IIA Appendix A, Continued 29 March 2001 (DCN: GE-021601-AAHM) Revised May 2003 (DCN: GE-022803-ABLZ) Environmental Remediation Contract General Electric (GE)/Housatonic River Project Pittsfield, Massachusetts Contract No. DACW33-00-D-0006 03P-1194-3A SM QUALITY ASSURANCE PROJECT PLAN, FINAL (REVISED 2003) Volume IIA—Appendix A, Continued October 27, 1999 (DCN: GEP2060499-AAIY) Revised May 2003 (DCN: GE-022803-ABLZ) Contract No. DACW33-00-D-0006 Prepared for U.S. ARMY CORPS OF ENGINEERS New England District 696 Virginia Road Concord, MA 01742-2751 Prepared by WESTON SOLUTIONS, INC. One Wall Street Manchester, NH 03101-1501 W.O. No. 20125.257.103.1625 MK01|O:\20125257.103\FINQAPP\QAPP_FIN_VIIA_FM_ALT.DOC 09/18/03 Contract No.: DACW33-00-D-0006 DCN: GE-022803-ABLZ Date: 05/03 Page i of iv TABLE OF CONTENTS—VOLUME IIA, APPENDIX A, CONTINUED APPENDIX A—STANDARD OPERATING PROCEDURES (CONTINUED) Appendix A-42—Standard Operating Procedure for Analysis of Pesticides and PCBs Collected on PUF Cartridges [Air Toxics] Appendix A-43—Standard Operating Procedure for Toxicity Characteristic Leaching Procedure [STL-VT] Appendix A-44—Standard Operating Procedure for Analysis of Chlorinated Pesticides in TCLP Extracts [STL-VT] Appendix A-45—Standard Operating Procedure for Analysis of Herbicides in TCLP Extracts [STL-VT] Appendix A-46—Standard Operating Procedure for Method 6010 TCLP Analysis by Inductively Coupled Plasma Spectroscopy [STL-VT]
    [Show full text]
  • Nassau BOCES
    Nassau BOCES Bid Information Contact Information Ship to Information Bid Owner Lisa Schwartz Buyer / Deputy Address PO Box 9195 Address AS INDICATED ON PURCHASE Purchasing Agent 71 Clinton Road ORDERS ISSUED AS A RESULT OF Email [email protected] Garden City, NY 11530-9195 THIS BID. Phone (516) 396-2231 Contact Lisa Schwartz Buyer / Deputy Fax Purchasing Agent NY Department Contact Bid Number 17/18-052 Science Supplies Building Department Title 17/18-052 Science Supplies Floor/Room Building Bid Type ITB Telephone Floor/Room Issue Date 09/19/2017 Fax Telephone Close Date 10/11/2017 02:00:00 PM (ET) Email [email protected] Fax Email Supplier Information Supplier Notes Company Name Contact Name Address Telephone Fax Email By submitting your response, you certify that you are authorized to represent and bind your company. Signature Date / / Bid Notes This bid contain a document attachment that has important information for potential bidders. Please review the attached document carefully before responding to this bid opportunity. You may respond to this bid electronically by clicking the 'Respond' button. Click the 'Help' button in the upper right-hand corner of the screen to access the Suppliers Users Guide for more information on responding to bids electronically. Bid Activities Bid Messages Bid Attachments The following attachments are associated with this opportunity and will need to be retrieved separately # Filename Description Header 17-18-052 Science Supplies.pdf 17/18-052 Science Supplies Bid Attachments Requested 17/18-052 Science Supplies - Page 1 of 305 The following attachments are requested with this opportunity Bid Attributes Please review the following and respond where necessary # Name Note Response 1 TERMS AND CONDITIONS By checking this box, you acknowledge that you have read ____________________ (Required) and agree to adhere to the Terms and Conditions of the bid as described in the General Terms & Conditions document that is part of this bid.
    [Show full text]
  • Used for Moving Beakers Off of Hot Surfaces
    Lab Equipment and Use Review Sheet Glassware Function Glassware Function Glassware Function Running Accurately Running reactions, measuring/ reactions, heating chemicals mixing mixing delivering chemicals – chemicals, volumes of easier for mixing Beaker heating Buret liquids than beakers chemicals Erlenmeyer Flask Used in Running Used to mix vacuum reactions, chemicals to heating filtration chemicals accurately mixing determine chemicals – concentration; Volumetric easier for contains exact Florence Flask Flask Filter Flask mixing than volumes beakers Used for Used for Used for mixing filtering and accurately and heating chemicals and for adding measuring running chemicals the volume reactions– without of liquids. smaller quantities Funnel Graduated spilling Test Tube than beakers and Cylinder flasks. Holding For stirring For storing Chemicals, Glass Stirring Rod chemicals small amounts covering of chemicals Watch Glass beakers during Sample Vial heating For adding Used to small evaporate amounts of Used for Evaporating liquids chemicals – lighting burner Dish usually by Plastic Pipets drops Used to add Utility Clamp – deionized used to hold water; to add objects on a solvents for ring stand. cleaning of Iron ring – Squirt Bottle beakers and used to hold other objects above glassware. a Bunsen burner flame. Ring Stand Ring stand – Beaker Tongs with Utility used to hold Clamp and various Iron Ring objects. Equipment Function Equipment Function Equipment Function Heat source in Used to grind Used to clean the chemistry chemicals into glassware lab. Uses powder natural gas. Mortar and Pestle Test tube brush/beaker Bunsen Burner brush Used to hold a Used to Used to crucible above transport hot strongly heat a flame – used Crucible tongs crucibles and substances Clay triangle in conjunction to remove Crucible and above a flame with iron ring their covers Cover Used to hold Used to handle a Used in group of test single test tube.
    [Show full text]
  • Talboys Clamp Catalog
    1 2 Clamps Clamps The unique design of these clamps, rods and supports, connectors, and Prong Type: accessories, conceivably offers one of the most extensive selections in the Two-prong clamps are ideal for holding straight-sided apparatus such as burets, industry. With a variety of sizes, materials, hardware, and designs, there is thermometers, beakers, and flask necks. Three-prong clamps are more versatile always an option to accommodate any application. and have the added capability of holding irregularly shaped objects. Clamps are supplied with both non-slip vinyl sleeves and, for temperatures above 100°C, • Clamps firmly grip lab apparatus fiberglass covers. • Ergonomic designs Prong Adjustment: • Durable, heavy-duty parts Single adjust clamps are great for applications where limited jaw adjustment • Built to last is required. One prong or “finger” is adjusted using a wing nut, while the other prong remains stationary. Dual adjust clamps offer a greater flexibility because The following are many options to consider when choosing the right clamp to both prongs are adjustable over a wider range. Thumbscrews are utilized for suit your needs: easier prong adjustment. Material: Holders and Connectors: A majority of the LabJaws clamps are made of nickel-plated zinc which possess A variety of holders and connectors are available to secure apparatus specific to a high tensile strength paired with an economical price. Stainless steel is an the different angles, diameters, and weights in your application allowing you to option that offers higher chemical resistance and durability. Aluminum is another customize as needed. material that is used in some of the products to offer a greater strength with a Lab-Frames: lighter weight.
    [Show full text]
  • Stirrer & Mixer
    Stirrer & Mixer Certification of conformity of electricity, Satisfaction with the requirements of Registered patent based on gas, etc. in accordance with the safety European regulations and guidelines. JEIO TECH’s proprietary technology. standards of Canada and USA. Recognized as an excellent Compliance with Guidelines for More precise temperature control design product by the Ministry of Restriction of Hazardous through temperature calibration. Commerce, Industry, and Energy. Substances Use. Maintains possible maximum Over temperature protection Intuitive operation orbital motion without stopping, function. with Color Touch display. even if overload occurs. Control of temperature / humidity If the surface temperature of the Possible to check and control / rpm / time, etc. through dedicated hot plate exceeds 50 degrees, temperature of sample by connecting program. the warning lamp turns on. to device with an external sensor. Possible to set end time or start 2 year warranty Free A/S. time of device operation. 124 General Application Hotplate: Acid and base digestions, trace metal analysis, sample drying, general reagent heating, evaporation. Hotplate Stirrer: Accurate, stable, and highly-reproducible in various heating stirring experiments. Magnetic Stirrer: Crystallization, solvent evaporation, chemical reaction, titration, distillation, media dissolution, food processing. Overhead Stirrer: Petrochemical sector, beverage/hot water product/dairy product production, food processing. Vortex Mixer: Powerful mixing of solutions. Max. Max.
    [Show full text]