Used for Moving Beakers Off of Hot Surfaces

Total Page:16

File Type:pdf, Size:1020Kb

Used for Moving Beakers Off of Hot Surfaces Lab Equipment and Use Review Sheet Glassware Function Glassware Function Glassware Function Running Accurately Running reactions, measuring/ reactions, heating chemicals mixing mixing delivering chemicals – chemicals, volumes of easier for mixing Beaker heating Buret liquids than beakers chemicals Erlenmeyer Flask Used in Running Used to mix vacuum reactions, chemicals to heating filtration chemicals accurately mixing determine chemicals – concentration; Volumetric easier for contains exact Florence Flask Flask Filter Flask mixing than volumes beakers Used for Used for Used for mixing filtering and accurately and heating chemicals and for adding measuring running chemicals the volume reactions– without of liquids. smaller quantities Funnel Graduated spilling Test Tube than beakers and Cylinder flasks. Holding For stirring For storing Chemicals, Glass Stirring Rod chemicals small amounts covering of chemicals Watch Glass beakers during Sample Vial heating For adding Used to small evaporate amounts of Used for Evaporating liquids chemicals – lighting burner Dish usually by Plastic Pipets drops Used to add Utility Clamp – deionized used to hold water; to add objects on a solvents for ring stand. cleaning of Iron ring – Squirt Bottle beakers and used to hold other objects above glassware. a Bunsen burner flame. Ring Stand Ring stand – Beaker Tongs with Utility used to hold Clamp and various Iron Ring objects. Equipment Function Equipment Function Equipment Function Heat source in Used to grind Used to clean the chemistry chemicals into glassware lab. Uses powder natural gas. Mortar and Pestle Test tube brush/beaker Bunsen Burner brush Used to hold a Used to Used to crucible above transport hot strongly heat a flame – used Crucible tongs crucibles and substances Clay triangle in conjunction to remove Crucible and above a flame with iron ring their covers Cover Used to hold Used to handle a Used in group of test single test tube. conjunction with For transport, iron ring. Evens tubes. holding test tube out the heat of a Test Tube Test tube in a flame or Wire Gauze flame on the Rack placing test tube bottom of a holder in hot water bath beaker and supports the beaker on the iron ring. For holding a For clamping For storing pair of burets things to the chemicals on a ring ring stand stand. Clamp Holder Buret Clamp Wide mouth Bottle For grabbing substances Tweezers Used to filter Used to solids from transfer solid liquids chemicals from Filter Paper the bottle Spatula, Scoop Scoopula For measuring Plastic trays with temperature. various number of Alcohol have red wells for running bulbs, mercury reactions have a silver Thermometer colored bulb Well Plate .
Recommended publications
  • AOAC Official Method 2011.25 Insoluble, Soluble, and Total Dietary Fiber in Foods
    AOAC Official Method 2011.25 supplies/fisherbrand.html) or 250 mL polypropylene bottles with Insoluble, Soluble, and Total Dietary Fiber in Foods polypropylene caps. Enzymatic-Gravimetric-Liquid Chromatography (c) Fritted crucible.—Gooch, fritted disk, Pyrex® 50 mL, First Action 2011 pore size, coarse, ASTM 40–60 µm (Corning No. 32940-50C® [Applicable to plant material, foods, and food ingredients or equivalent; http://www.labplanet.com/corning-crucible-gooch- consistent with CODEX Alimentarius Commission high-c-50-ml-32940-50c.html). Prepare four for each sample as Definition adopted in 2009 and modified slightly in 2010 follows: Ash overnight at 525°C in muffle furnace. Cool furnace to (ALINORM 09/32/REP and ALINORM 10/33/REP, respectively), 130°C before removing crucibles to minimize breakage. Remove including naturally occurring, isolated, modified, and synthetic any residual Celite and ash material by using a vacuum. Soak in 2% polymers meeting that definition.] cleaning solution, C(i), at room temperature for 1 h. Rinse crucibles See Tables 2011.25A–H for the results of the interlaboratory with water and deionized water. For final rinse, use 15 mL acetone study supporting acceptance of the method. and air dry. Add approximately 1.0 g Celite to dried crucibles and A. Principle dry at 130°C to constant weight. Cool crucible in desiccators for approximately 1 h and record mass of crucible containing Celite. A method is described for the measurement of insoluble, (d) Filtering flask.—Heavy-walled, 1 L with side arm. soluble, and total dietary fiber (IDF, SDF, and TDF, respectively), (e) Rubber ring adaptors.—For use to join crucibles with inclusive of the resistant starch (RS) and the water:alcohol soluble filtering flasks.
    [Show full text]
  • Table of Contents
    Manufacturing Science and Technology, ICMST2011 ISBN(softcover): 978-3-03785-295-8 ISBN(eBook): 978-3-03813-758-0 Table of Contents Preface and Organizing Committee Chapter 1: Computer-Aided Manufacturing Automatic On-Line Detection and Sorting System Design and Implementation for Paper- Making Printing R.X. Sun, L. Gao, J. Kang, P.P. Huang, Y. Tian and X.F. Chen 3 Design and Realization of Monitoring System for Multiway pH Value R.X. Sun, P.P. Huang, N. Ran, J. Kang, X.F. Chen and Y. Tian 6 The CAD/CAM of Hydraulic Valve Block Based on Pro/Engineer W.L. Wu, X.J. Jin and K.L. Xing 12 Design and Implementation of a Computer Vision Based Inspection System Using CUDA Y. Shi, A.G. Li and L. Wang 18 Structure Reverse Design and CFD Analysis on Agitated Flow Field of Submersible Mixer W.X. Xu and M.Y. Fan 25 Robust State-Feedback Controller Design for Uncertainty Singular Systems L.M. Liang, F.L. Weng and Y.C. Ding 32 An Estimation Approach Based on Predictive Filtering to Missile Guidance Y.Y. Song, W.C. Chen and X.L. Yin 38 Controller Design for Spinning Missile with the Actuator Limit F. Liu and W.C. Chen 45 The Time-Delay Study on Vehicle Active Control Suspension F.R. Kou 52 The Research on High-Voltage Transmission Line Relay Protection Setting Related to OLTC Anti-Icing S.Q. Liu, H. Wang, X.M. Li and D.X. Zhou 59 Development of Islanding Detection Based on Power Controlling for Grid-Connected of Dispersed Power Generation W.M.
    [Show full text]
  • FS/2018 ORGANIC CHEMISTRY I LAB CHEM 226 (2219) Instructor
    FS/2018 ORGANIC CHEMISTRY I LAB CHEM 226 (2219) Instructor: Terry Bone 120-B Schrenk Hall [email protected] 341-4820 http://www.mst.edu/~tbone 9:00-10:00, Tu-Th, or by appt. Cynthia Bolon 213 Schrenk Hall [email protected] 341-4439 OBJECTIVES: Course objectives are to develop facility with performing laboratory techniques involving the handling of organic chemicals safely and the keeping of proper records of experiments conducted in the laboratory. Crystallization, distillation, extraction and chromatography are emphasized as separation and purification techniques. Melting points, boiling points, and refractive indices are used routinely as measures of purity. Safe handling of chemicals and proper disposal of waste products are priority goals in this course. To help in attaining such goals, the first week of the semester is devoted to SAFETY in the chemistry laboratory. For the remainder of the semester, most of the experiments are conducted on a micro scale. BOOKS: 1. 100 pg. set Organic Chemistry Laboratory Notebook 2. “Organic Chemistry Laboratory Laboratory Techniques, 2nd ed”. Available as free pdf download at https://open.umn.edu/opentextbooks/BookDetail.aspx?bookId=369 3. “Microscale Techniques for the Organic Laboratory, 2nd ed”, (MTOL), Mayo, Pike, Butcher and Trumper, John Wiley & Sons, Inc.,2001 (on reserve at library circulation desk-currently out of print but available on Amazon) 4. “Right to Know pocket guide for School & University Employees”, Genium Publishing Corp., 1990. (optional) (#1 can be purchased from the book store) LAB SYLLABUS: Originally prepared by Prof. S. B. Hanna, modified by D. E. Hoiness, T.Bone. GENERAL GUIDELINES SAFETY Goggles must be worn at all times in the lab.
    [Show full text]
  • Microbiological Control 2 Intro | Table of Contents Content
    Microbiological Control 2 Intro | Table of Contents Content Table of Contents Microbiological Enumeration 6 Membrane Filters 28 Filtration Equipment Sterility Testing 60 Sterisart® Universal Pump 61 Sterisart® NF – Sterility Test Disposables 65 Reusable Sterility Test System Mycoplasma Contamination Control 70 Microsart® AMP Mycoplasma Air Monitoring 74 MD8 airscan® 75 AirPort MD8 76 Gelatine Membrane Filters 77 BACTair™ – Big Impact 78 Accessories Chemical Compatibility 84 Filter Materials & Mini Cartridges 86 Filter Holder | Cartridge Housing | O-ring Materials 88 Ready-to-Connect Filtration Units 90 Index Intro AirMicrobiological Monitoring Enumeration 5 Microbiological Enumeration Table of Contents 6 Membrane Filters 28 Filtration Equipment 6 Microbiological Enumeration Membrane Filters Membrane Filters 7 Gridded Cellulose Nitrate Membrane Filters (Cellulose Mixed Ester) acc. to ISO Standards 8 Cellulose Nitrate (Cellulose Mixed Ester) Membrane Filters 12 Microsart® e.motion Membrane Filters 13 Microsart® e.motion Dispenser 14 Cellulose Nitrate and Cellulose Acetate Membrane Filters 16 Hydrophobic Edged Membrane Filters 18 Nutrient Pad Sets 22 Culture Media in Bottles and Tubes 24 Biosart® 100 Monitors 27 Biosart® 100 Nutrient Media Membrane Filters Microbiological Enumeration 7 Gridded Cellulose Nitrate Membrane Filters (Cellulose Mixed Ester) acc. to ISO Standards Sterile and Individually Packaged, the methods of the Central European for Colony Counting Brewery Commission, the MNO Sterile, individually packed filters have (Mineral|Table Water Guideline), the long become standard for routine microbi- National Canners Association, the testing ological quality control because of the procedures for packaging stuff, the user benefits they offer. U.S. Environmental Protection Agency, the United States Pharmacopoeia, the They are pre-sterilized and ready-to-use US Department of Agriculture, the VLB and save preparatory time.
    [Show full text]
  • LAB: One Tube Reaction Part 1
    AP Chemistry LAB: One Tube Reaction Part 1 Objective: To monitor and document the chemical changes occurring in a single test tube containing a predetermined mixture of chemicals. Materials: test tube, iron nail, sodium chloride, copper (II) sulfate, distilled water, glass stirring rod, tissue paper, parafilm wax Procedures: 1. Label a test tube to identify your group 2. Fill approx. 1/3 of the test tube with copper (II) sulfate crystals. Gently tap the tube to allow the crystals to settle. 3. Using a glass stirring rod, carefully cover the crystals with a layer of Kimwipe tissue paper. 4. Slowly, and with as little disturbance as possible, add enough distilled water to just cover the paper and blue crystals. 5. Repeat the process for the sodium chloride, filling approx. 1/3 of the test tube. Gently tap the tube to allow the crystals to settle. 6. Push more tissue paper into the test tube on top of the white crystals. 7. Add enough water to cover the tissue paper and white crystals. 8. Obtain an iron nail and expose the surface by rubbing with sand paper. 9. Carefully slide the nail into the test tube. 10. Continue adding water until the nail is completely covered. 11. Cover the test tube with parafilm wax and record your Day 1 observations. 12. Return the test tube to the test tube rack. 13. Continue to monitor and record your observations for the next several days, as indicated in the data table. Data: 1. Complete the NFPA label for the two chemicals used in this lab.
    [Show full text]
  • Determination of the Identity of an Unknown Liquid Group # My Name the Date My Period Partner #1 Name Partner #2 Name
    Determination of the Identity of an unknown liquid Group # My Name The date My period Partner #1 name Partner #2 name Purpose: The purpose of this lab is to determine the identity of an unknown liquid by measuring its density, melting point, boiling point, and solubility in both water and alcohol, and then comparing the results to the values for known substances. Procedure: 1) Density determination Obtain a 10mL sample of the unknown liquid using a graduated cylinder Determine the mass of the 10mL sample Save the sample for further use 2) Melting point determination Set up an ice bath using a 600mL beaker Obtain a ~5mL sample of the unknown liquid in a clean dry test tube Place a thermometer in the test tube with the sample Place the test tube in the ice water bath Watch for signs of crystallization, noting the temperature of the sample when it occurs Save the sample for further use 3) Boiling point determination Set up a hot water bath using a 250mL beaker Begin heating the water in the beaker Obtain a ~10mL sample of the unknown in a clean, dry test tube Add a boiling stone to the test tube with the unknown Open the computer interface software, using a graph and digit display Place the temperature sensor in the test tube so it is in the unknown liquid Record the temperature of the sample in the test tube using the computer interface Watch for signs of boiling, noting the temperature of the unknown Dispose of the sample in the assigned waste container 4) Solubility determination Obtain two small (~1mL) samples of the unknown in two small test tubes Add an equal amount of deionized into one of the samples Add an equal amount of ethanol into the other Mix both samples thoroughly Compare the samples for solubility Dispose of the samples in the assigned waste container Observations: The unknown is a clear, colorless liquid.
    [Show full text]
  • Performance Validation of the Microbiologique Microfilm Test
    MAI ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 101, NO. X, 2018 1 FOOD BIOLOGICAL CONTAMINANTS Performance Validation of the Microbiologique MicrofilmTM Test System for AOAC Research Institute Performance Tested Method SMCertification AOAC Performance Tested Method SM 051702 Abstract ANNA SHAPOVALOVA and HARISH K. JANAGAMA Molecular Epidemiology, Inc., 15300 Bothell Way NE, The Microfilm™ Test System is intended for quantitative Lake Forest Park, WA 98155 microbiology and consists of three types of Microfilms for aerobic LONG VUONG and ALEX FRIEDRICH plate count (Microfilm APC), total coliform and Escherichia coli IEH Laboratories and Consulting Group, Inc., 15300 Bothell count (Microfilm TCEc), and yeast and mold count (Microfilm Way NE, Lake Forest Park, WA 98155 YMC). This study evaluated the performance of the Microfilm DYLAN JOHNSON Test System against International Organization for Standardization Molecular Epidemiology, Inc., 15300 Bothell Way NE, (ISO) methods on 20 food matrixes and 2 environmental surfaces. Lake Forest Park, WA 98155 Ruggedness, robustness, and stability were also determined, LOURDES M. NADALA while inclusivity and exclusivity studies were performed on Molecular Epidemiology, Inc., 15300 Bothell Way N.E., Microfilm TCEc and YMC. An independent laboratory evaluated Lake Forest Park, WA 98155; Microbiologique, the performance on four food matrixes and one environmental Inc., 8215 Lake City Way NE, Seattle, WA 98115 surface. No significant differences and high correlation coefficients VAN NGUYEN were observed between the Microfilm Test System and the Microbiologique, Inc., 8215 Lake City Way NE, Seattle, corresponding ISO methods (ISO 4833-1:2013 for APC, ISO WA 98115 4832:2006 for total coliform count, ISO 16649-2: 2001 for E.
    [Show full text]
  • Funnels and Filters
    51 FUNNELS AND FILTERS Buchner Funnels 260MM (10.25") INSIDE DIAMETER, 203MM (8") OVERALL HEIGHT, 127MM (5") RIM TO PLATE CATALOG NO. DESCRIPTION PRICE/EACH H14620-0000 Funnel with Coarse Porosity Fixed Plate $216.00 H14620-1260 Funnel with Coarse Porosity Removable Plate 216.00 H14625-3510 Funnel with Medium Porosity Fixed Plate 216.00 H14626-3510 Funnel with Medium Porosity Removable Plate 216.00 H14627-0000 Funnel with Perforated Fixed Plate 216.00 Table-Top H14627-1260 Funnel with Perforated Removable Plate 216.00 Buchner 457MM (18") INSIDE DIAMETER, 292MM (11.5") OVERALL HEIGHT, 203MM (8") RIM TO PLATE Funnels CATALOG NO. DESCRIPTION PRICE/EACH With Fritware® Porous H14621-0000 Funnel with Coarse Porosity Fixed Plate $540.00 Filter or HDPE H14621-1457 Funnel with Coarse Porosity Removable Plate 540.00 H14625-3518 Funnel with Medium Porosity Fixed Plate 540.00 Perforated Plate H14626-3518 Funnel with Medium Porosity Removable Plate 540.00 Polyethylene funnels are H14628-0000 Funnel with Perforated Fixed Plate 465.00 one piece design with a H14627-1457 Funnel with Perforated Removable Plate 465.00 FIXED or REMOVABLE Custom sizes available upon request. 610MM (24") INSIDE DIAMETER, 330MM (13") OVERALL HEIGHT, 267MM (10.25") RIM TO PLATE porous filter plate CATALOG NO. DESCRIPTION PRICE/EACH supported by a multiple ring grid. Filter plates are made of high density H14622-0000 Funnel with Coarse Porosity Fixed Plate $1125.00 1 polyethylene 6.4mm ( ⁄4") thick with a non-porous ring at the periphery of the plate H14622-1610 Funnel with Coarse Porosity Removable Plate 1125.00 1 H14625-3524 Funnel with Medium Porosity Fixed Plate 1125.00 which seals filter paper when used.
    [Show full text]
  • Equipment Detailsr07
    Lab Equipment Details Lab Equipment Glass Flasks 150ml 250ml 500ml Lab Equipment Glass Beakers 150ml 250ml 500ml Lab Equipment Glassware But once removed, only the cap stays highlighted. Droppers critical to Lab An activated Dropper coursework can be found highlights the entire bottle. already in the workspace. Dropper Dropper Dropper Activated In Use Lab Equipment Gastight Syringe Small A pre-filled gastight syringe can be used with a NMR tube to safely fill through the top in preparation for use with the NMR spectrometer. Gastight Syringe NMR Tube with Holder with Holder Lab Equipment NMR Tube Spinner An NMR Tube filled with gas for use with the NMR Spectrometer Simply use the NMR Tube with needs to be inserted into the the Tube Spinner. Spinner before it can be used. NMR Tube NMR Tube Spinner NMR Tube Spinner with Holder with NMR Tube inserted Once the Tube slotted into the holder is inserted into the top part of the spectrometer, users can type in a number for Lab Equipment the frequency they’d like to scan. NMR Spectrometer XL The NMR Tube holder can then be slotted into the highlighted tube on the NMR Spectrometer. NMR Tube filled with appropriate substance is slotted (used with) in the holder. Lift will perpare the Spectrometer for the tube holder insertion. Scan No. Allows the user to change the frequency at which the tube is scanned The NMR Tube holder can then be slotted into the top tube on Lab Equipment the NMR Spectrometer. NMR Spectrometer XL NMR Tube filled with appropriate substance is slotted (used with) in the holder.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Flinn Scientific 2019 Purchase Guide a Quick and Easy Checklist of Science Essentials
    Flinn Scientific 2019 Purchase Guide A Quick and Easy Checklist of Science Essentials Use this Purchase Guide as a handy tool for: • Taking Inventory • Order Preparation • Budget Management • Future Planning See your Flinn Scientific Catalog/Reference Manual SCIENTIFIC or visit www.flinnsci.com for product details. It’s Easy to Order Tom Trapp from Flinn Scientific! National Account Development Consultant [email protected] www.flinnsci.com/tom-trapp/sa1001 Online 402-960-5578 (mobile) www.flinnsci.com Offering personal assistance to help meet your science curriculum, supply, and lab safety needs. Email [email protected] Quality Products, Fast Delivery, Fax and Low Prices Guaranteed 1-866-452-1436 (toll free) Mail Flinn Scientific, Inc. P.O. Box 219 Batavia, IL 60510-0219 Phone 1-800-452-1261 7:30 am to 5:00 pm CT Monday through Friday Our Guarantee Flinn Scientific, Inc. guarantees that no sale is complete unless the customer is satisfied. Every item we furnish will either conform to the catalog specification, or we will ask your permission, prior to shipment, to ship an alternative product. If you find a lower published nationally advertised catalog price for an identical item, Flinn will “meet or beat” that price. Use this purchase guide containing popular product recommendations ©2019 Flinn Scientific, Inc. All Rights Reserved. to prepare your order, take inventory, and manage your budget. 1 www.flinnsci.com Flinn Scientific 2019 Purchase Guide 1 Item Rec. Item Rec. Product / Item Name Qty 2019 Price Total Product / Item Name Qty 2019 Price Total No. Qty No. Qty Safety & Personal Protection Equipment Aspirator, Water, Polypropylene AP1203 1 $ 19.30 $ - Apron, rubberized, 27" W X 36" L AP7125 30 $ 15.00 $ - Autoclave, Electric, Portable AP1004 1 $ 865.20 $ - Apron, plastic, 30" W x 36" L AP7120 30 $ 7.25 $ - ♦ Balance, Flinn Triple Beam OB2181 $ 115.00 $ - Gloves, Butyl rubber for conc.
    [Show full text]
  • Bunsen Burner Safety
    Proper Use of a Bunsen Burner If using a Bunsen burner in a biological safety cabinet, see: http://research.wayne.edu/oehs/pdf/gas-in-bsc.pdf Prior to Lighting Bunsen Burner: • Know the location of the laboratory’s main gas shut off valve and fire extinguisher. • Place the Bunsen burner away from any overhead shelving, equipment, or light fixtures by at least 12 inches. • Remove all papers, notebooks, combustible materials, and excess chemicals from the area. • Tie-back any long hair, dangling jewelry, or loose clothing. • Use correct tubing (butyl rubber hose). Inspect hose for cracks, holes, pinch points, or any defect and replace if necessary. Ensure that the hose fits securely on the gas valve and the burner. • Notify others in the lab that the burner will be in use. Lighting Bunsen Burner: • Before turning on gas, have a sparker/lighter with extended nozzle to ignite burner. Never use matches. • Check connections to burner and desk outlet valve. • Close needle valve and collar. • Open gas valve fully. • Open needle valve 1/2 turn. • Use the spark/lighter to light the flame. • Adjust flame by turning the collar to regulate air flow and produce an appropriate flame for the experiment (typically a medium blue flame). During Use: • Never leave a lighted burner unattended. Drafts (including those created by a hood) may extinguish the flame, but the gas will still be on. This could result in an explosion. • Never face the vessel (test tube, beaker, etc.) being used to heat a material toward yourself or others near the burner. In some experiments, a hot plate may be used in place of the Bunsen burner.
    [Show full text]