Strain Measurement

Total Page:16

File Type:pdf, Size:1020Kb

Strain Measurement Strain Measurement Prof. Yu Qiao Department of Structural Engineering, UCSD Strain Measurement • The design of load-carrying components for machines and structures requires information about the distribution of forces within the particular component. • Often we need to consider the deflection capacity. • This can be analyzed based on the measurement of physical displacements. 1 Strain Measurement • A simple example is the slender rod that is placed in uniaxial tension. • Forcer per unit area is called stress. • Design criterion is often based on the stress levels. • The stress can be calculated through the measured deflection. Stress and Strain • The experimental measurement of stress is always accompanied with the determination of strain. • The ratio of the change in length of the rod to the original length is the axial strain: a = L/L • For most engineering materials, strain is a small quantity, usually in units of 10-6 in/in or 10-6 m/m. 2 Resistance Strain Gauge • The measurement of the small displacements that occurs in a material or object under mechanical load determines the strain. • Strain can be measured by methods as simple as observing the change in the distance between two scribe marks, or as advanced as optical holograph. • In any case, the sensor would ; (1) have good spatial solution, i.e. the sensor should measure the strain at a “point”; (2) be unaffected by change in ambient conditions; and (3) have a high-frequency response for dynamic (time- based) strain measurement. • One of the most commonly used device is the bonded resistance strain gauge. Resistance Strain Gauge • There are metallic gauges. • Consider a conductor having a uniform cross- sectional area, Ac, and a length, L, made of a material having a resistivity, e. The overall resistance is given by R = e L/Ac • If the conductor is subject to a normal stress along the axis of the wire, the cross-sectional area and the length will change, which in turn affect R. 3 Resistance Strain Gauge Hence, the changes in resistance are caused by two basic effects: the change in geometry as the length and cross- sectional area change, and the change in the value of the resistivity. The dependence of the resistivity on the strain is called piezoresistance and may be expressed in terms of a piezoresistance coefficient: Young’s modulus Poisson’s ratio Gauge factor (GF) Resistance Strain Gauge • For example, consider a copper wire having a diameter of 1 mm and a length of 5 cm. The resistivity is 1.710-8 m. 4 Resistance Strain Gauge • Another example. A very common material for the construction of strain gauge is the alloy constantan (55% copper with 45% nickel) having a resistivity of 4910-8 m. A typical strain gauge may have a resistance of 120 . What length of constantan wire of diameter 0.025 mm would yield this resistance? Resistance Strain Gauge • Through this example we can see that a single straight conductor is normally not practical for strain measurement. • A simple solution is to bend the wire conductor so that several lengths of wire are oriented along the axis of the strain gauge. www.doitpoms.ac.uk 5 Resistance Strain Gauge • A typical metallic-foil bonded strain gauge consists of a metallic foil pattern that is formed in a manner similar to the process used to produced printed circuits. • The foil is mounted on a plastic backing material. • The gauge length is an important specification for a particular application. Resistance Strain Gauge • Since strain is usually measured at the location where the stress is a maximum and the stress gradients is high, the strain gauge averages the measured strain over the gauge length. • Usually the maximum strain is the quantity of interest. Thus, errors can result from improper choice of a gauge length. • Special mounting techniques and constructions are required for the variety of application conditions, including design variations in the backing material, the grid configuration, bonding techniques, and total gauge electrical resistance. 6 Resistance Strain Gauge • The strain gauge backing serves several important functions. • It electrically isolates the metallic gauge from the test specimen and transmits the applied strain to the sensor. • The backing provides the surface used for bonding with an appropriate adhesive. • Backing materials are available that are useful over temperature ranging from -270 to 290oC. Resistance Strain Gauge • The adhesive bond serves as a mechanical and thermal coupling between the metallic gauge and the test specimen. • The strength of the adhesive should be sufficient to accurately transmit the strain. • It should have thermal conduction and thermal expansion characteristics suitable for the application. • A wide array of adhesives are available, e.g. epoxies, cellulose nitrate cement, and ceramic- based cement. 7 Resistance Strain Gauge • If there are both normal and transverse components of strain, the total change in resistance of the gauge will be a result of both the axial and lateral components. • The goal of the strain gauge design is to create a sensor that is sensitive only to strain along one axis, and has negligible sensitivity to lateral and shear deformation. • Actual strain gauges are sensitive to lateral strains to some degree; while the sensitivity to shearing strains is often negligible. Resistance Strain Gauge • Semiconductor strain gauges are also commonly used. • Silicon crystals are the basic material. The crystals are sliced into very thin sections. • Due to the high piezoresistance coefficient, the semiconductor strain gauge exhibits a very high gauge factor, as high as 200 for some gauges! • They also have higher resistance, longer fatigue life, and lower hysteresis. • However, the output is nonlinear with strain, and the strain sensitivity or gauge factor may be remarkably dependent on temperature. 8 Resistance Strain Gauge • Semiconductors with high charge carrier density (~1020 carriers/cm3) exhibit little variation of their gauge factor with strain or temperature. • If the charge carrier density is low (<1017 carriers/cm3), Resistance Strain Gauge • Due to the capability for producing small gauge length, silicon semiconductor strain gauge is usually very small. • It allows the measurement of the strains with high frequencies. • However, special treatment is required if the environment is corrosive (e.g. in a liquid pressure measurement). • The maximum strain can be measured is usually below 0.005 (in compression ~0.05). 9 Strain Gauge Electrical Circuit •A Wheatstone bridge is generally used to detect the small changes in resistance that are the output of a strain gauge measurement circuit. • A typical sensitivity is ~10-6 /kNm2 • Commercially available equipment can measure changes in gauge resistance of less than 0.0005 ( ~ 0.0001%). Strain Gauge Electrical Circuit E is very sensitive to • The bridge output (voltage) Eo+Eo is o small change in R1 Voltage measurement Voltage • If all the fixed resistors and the strain gauge resistance are initially equal, and the bridge is balanced such that Eo = 0, • This equation is valid for all the circuits as long as R/R <<1. GF / 4 DC power source (voltage = Ei) 10 Strain Gauge Electrical Circuit • This bridge can be balanced by changing the resistance of one arm, and thus the bridge can be balanced without touching the gauge. Multiple gauges can be used to increase the bridge output and cancel out ambient effects. Strain Gauge Electrical Circuit • For example, consider a strain gauge with a gauge factor of 2 mounted on a rectangular steel bar (Em = 200 GPa). The bar is 3 cm wide and 1 cm high, and is subjected to a tensile force of 30 kN. Determine the resistance change of the strain gauge, if the resistance of the gauge was 120 in the absence of the axial load. 11 Strain Gauge Electrical Circuit The Multiple Gauge Bridge • The output from a bridge circuit can be increased by the appropriate use of more than one active strain gauge. • In addition, the use of multiple gauges can be used to compensate unwanted effects, such as temperature or specific strain components. • If all four resistances in the bridge circuit represent active strain gauges, the bridge output becomes 12 The Multiple Gauge Bridge • The four strain gauges are assumed initially to be in a state of zero strain. • If these gauges are now subjected to strains such that the resistances change by dRi, then • Evaluating the appropriate partial derivatives yields The Multiple Gauge Bridge If Ri is not a strain gauge but a constant resistor, it is eq’t to set i = 0 in this eq. Thus, for a bridge containing one or more active strain gauges, equal strains on opposite bridge arms sum, whereas equal strains on adjacent arms of the bridge cancel. These characteristics can be used to increase the output of the bridge, to provide temperature compensation, or to cancel unwanted components of strain. 13 Bridge Constant • Commonly used strain gauge bridge arrangements may be characterized by a bridge constant, , defined as the ratio of the actual bridge output to that output of a single gauge sensing the maximum strain, max (assuming the remaining bridge resistances remain fixed). • The output for a single gauge experiencing the maximum strain is is the ratio of the actual output to this value. Valid for all the systems if R/R << 1 Bridge Constant • For example, consider the bridge constant for two strain gauges mounted on a member. The member is subject to uniaxial tension, which produces an axial strain a and a lateral strain L = -pa. Assume that all the resistances are initially equal, and therefore the bridge is initially balanced. Let (GF)1 = (GF)2. GF GF 00 1 4 4 > 1 14 Apparent Strain and Temperature Compensation • Apparent strain is manifested as any change in gauge resistance that is not due to the component of strain being measured.
Recommended publications
  • Sensor Connectors
    Sensor Connectors Thermocouple Connector - Two Pole Assembly Termination Code: 2 • Glass filled thermoplastic body provides high strength at temperatures up to 425°F 218°C) as well as low moisture absorption and good dielectric constant . • Heavy duty hollow pin construction prevents reverse mating of polarity.* • Body color coded to ISA and ANSI standards. 1” • Polarity indicated by symbols molded into body. • Contacts made of thermocouple materials which meet ISA and ANSI standards . • Jack spring loaded to insure firm grip to plug. • Accepts wire sizes to 14 awg. • Single screw cover cap for fast assembly. • Accepts crimp and tube adapter for product from .020 to .375. • Finger grips to permit ease of connection. 7/16” • Quick wiring hook up with large head screws and wire channel. Catalog Number Thermocouple Body Actual Alloy Plugs Jacks Type Color + In Connector - 1/2” LP-J L J-J Iron-Constantan® Black Iron Constantan® LP-K L J-K Chromel®-Alumel® Yellow Chromel® Alumel® 7/8” LP-E L J-E Chromel®-Constantan® Violet Chromel® Constantan® LP-T L J-T Copper-Constantan® Blue Copper Constantan® 1 3/8” LP-R/S L J-R/S Platinum/Rhodium- Green Copper #11 Alloy Platinum LP-CU L J-CU Uncompensated White Copper Copper Assembly Termination Code: 5 *Solid pin available on above construction. Add S to Part No. (i.e. LPS-J) Miniature Thermocouple Connector Assembly Termination Code: 3 • Thermoplastic body provides high strength at temperatures up to 425°F (218°C) as well as low moisture absorption and good dielectric constant . • Small, light weight and space saving.
    [Show full text]
  • Strain Gage Technical Data
    STRAIN GAGE TECHNICAL DATA STRAIN GAGE MEASUREMENT The most universal measuring device for the electrical measurement of mechanical quantities is the strain gage. Several types of strain gages depend for their operation on the proportional variance of electrical resistance to strain: the piezoresistive or semi-conductor gage, the carbon resistive gage, the bonded metallic wire, and foil resistance gages. The bonded resistance strain gage is by far the most widely used in experimental stress analysis. This gage consists of a grid of very fine wire or foil bonded to a backing or carrier matrix. The electrical resistance of the grid varies linearly with strain. In use, the carrier matrix is bonded to the surface, force is applied, and the strain is found by measuring the change in resistance. The bonded resistance strain gage is low in cost, can be made with a short gage length, is only moderately affected by the bridge. This method assumes a wiring is located in a time-varying temperature changes, has small linear relationship between voltage magnetic field. out and strain, an initially balanced physical size and low mass, and Magnetic induction can be has fairly high sensitivity to strain. bridge, and a known VIN. In reality, the VOUT-strain relationship is controlled by using twisted lead In a strain gage application, the wires and forming minimum but carrier matrix and the adhesive nonlinear, but for strains up to a few thousand micro-strain, the error is equal loop areas in each side of must work together to transmit the the bridge. strain from the specimen to the grid.
    [Show full text]
  • Linear Thermal Expansion Coefficients of Metals and Alloys
    17 Material Expansion Coefficients Chapter 17 Material Expansion Coefficients Linear Thermal Expansion Coefficients of Metals and Alloys Linear Thermal Expansion Coefficients of Metals and Alloys Table 17-1 provides the linear thermal expansion coefficients of the most frequently used metals and allows. Table 17-1. Linear thermal expansison coefficients of metals and alloys Coefficient of Expansion Alloys ppm/°C ppm/°F ALUMINUM AND ALUMINUM ALLOYS Aluminum (99.996%) 23.6 13.1 Wrought Alloys EC 1060 and 1100 23.6 13.1 2011 and 2014 23.0 12.8 2024 22.8 12.7 2218 22.3 12.4 3003 23.2 12.9 4032 19.4 10.8 5005, 5050, and 5052 23.8 13.3 5056 24.1 13.4 5083 23.4 13.0 5086 23.9 13.3 5154 23.9 13.3 5357 23.7 13.2 5456 23.9 13.3 6061 and 6063 23.4 13.0 6101 and 6151 23.0 12.8 7075 23.2 12.9 7090 and 7178 23.4 13.0 17-2 User’s Manual Chapter 17 Material Expansion Coefficients Linear Thermal Expansion Coefficients of Metals and Alloys Table 17-1. Linear thermal expansison coefficients of metals and alloys (Cont.) Coefficient of Expansion Alloys ppm/°Cppm/°F ALUMINUM AND ALUMINUM ALLOYS (Continued) Casting Alloys A13 20.4 11.4 43 and 108 22.0 12.3 A108 21.5 12.0 A132 19.0 10.6 D132 20.5 11.4 F132 20.7 11.5 138 21.4 11.9 142 22.5 12.5 195 23.0 12.8 B195 22.0 12.3 214 24.0 13.4 220 25.0 13.9 319 21.5 12.0 355 22.0 12.3 356 21.5 12.0 360 21.0 11.7 750 23.1 12.9 40E 24.7 13.8 COPPER AND COPPER ALLOYS Wrought Coppers Pure Copper 16.5 9.2 Electrolytic Tough Pitch Copper (ETP) 16.8 9.4 Deoxidized Copper, High Residual Phosphorous (DHP) 17.7 9.9 Oxygen-Free Copper 17.7 9.9 Free-Machining Copper 0.5% Te or 1% Pb 17.7 9.9 User’s Manual 17-3 Chapter 17 Material Expansion Coefficients Linear Thermal Expansion Coefficients of Metals and Alloys Table 17-1.
    [Show full text]
  • Standard Cells: Their Construction, Maintenance, and Characteristics
    NBS MONOGRAPH 84 Standard Cells Their Construction, Maintenance, And Characteristics U.S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS THE NATIONAL BUREAU OF STANDARDS The National Bureau of Standards is a principal focal point in the Federal Government for assur- ing maxinmm application of the physical and engineering sciences to the advancement of technology in industry and commerce. Us responsibilities include development and maintenance of the national standards of measurement, and the provisions of means for making measurements consistent with tliose standards; determination of physical constants and properties of materials; development of methods for testing materials, meciianisms, and structures, and making such tests as may be neces- sary, particularly for government agencies; cooperation in the establishment of standard practices for incorporation in codes and specifications; advisory service to government agencies on scientific and technical problems; invention and development of devices to serve special needs of the Government; assistance to industry, business, and consumers in the development and acceptance of commercial standards and simplified trade practice recommendations; administration of programs in cooperation w ith Lnited States business groups and standards organizations for the development of international standards of practice: and maintenance of a clearinghouse for the collection and dissemination of scientific, technical, and engineering information. The scope of the Bureau's activities is suggested in the following listing of its four Institutes and their organizational units. Institute for Basic Standards. Electricity. Metrology. Heat. Radiation Physics. Me- chanics. Applied Mathematics. Atomic Physics. Physical Chemistry. Laboratory Astrophysics.* Radio Standards Laboratory: Radio Standards Physics; Radio Standards Engineering.** Office of Standard Reference Data. Institute for -Materials Research.
    [Show full text]
  • Abstract Instrument to Measure the Heat Capacity
    ABSTRACT INSTRUMENT TO MEASURE THE HEAT CAPACITY OF SMALL SAMPLES A calorimeter is used to make measurements of the internal energy of a material in order to probe its thermodynamic properties, such as crystalline lattice stiffness, electronic effective mass, phase transitions, and entropy. Rare-earth metallic compounds are of interest in our lab because they are known to exhibit strongly correlated electron behavior, which gives rise to interesting phenomenon such as conventional and unconventional superconductivity, metal-insulator transitions, magnetism, and the magnetocaloric effect. The temperature dependence of specific heat is an important quantity to investigate of these materials. With limited space of our cryogenic system, we are unable to construct a calorimeter that is perfectly thermally isolated; therefore, the use of a thermal relaxation method for our heat capacity measurements will be used. A discussion on the construction of a calorimeter and implementation of the relaxation calorimetery method will be presented. Ulises Ivan Urbina August 2010 INSTRUMENT TO MEASURE THE HEAT CAPACITY OF SMALL SAMPLES by Ulises Ivan Urbina A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Physics in the College of Science and Mathematics California State University, Fresno August 2010 APPROVED For the Department of Physics: We, the undersigned, certify that the thesis of the following student meets the required standards of scholarship, format, and style of the university and the student's
    [Show full text]
  • Strain Gage Selection: Criteria, Procedures, Recommendations
    MICRO-MEASUREMENTS Strain Gages and Instruments Tech Note TN-505-6 Strain Gage Selection: Criteria, Procedures, Recommendations 1.0 Introduction It must be appreciated that the process of gage selection generally involves compromises. This is because parameter The initial step in preparing for any strain gage installation choices which tend to satisfy one of the constraints or is the selection of the appropriate gage for the task. It might requirements may work against satisfying others. For at first appear that gage selection is a simple exercise, of no example, in the case of a small-radius fillet, where the great consequence to the stress analyst; but quite the opposite space available for gage installation is very limited, and is true. Careful, rational selection of gage characteristics the strain gradient extremely high, one of the shortest and parameters can be very important in: optimizing available gages might be the obvious choice. At the the gage performance for specified environmental and same time, however, gages shorter than about 0.125 in operating conditions, obtaining accurate and reliable strain (3 mm) are generally characterized by lower maximum measurements, contributing to the ease of installation, and elongation, reduced fatigue life, less stable behavior, and minimizing the total cost of the gage installation. greater installation difficulty. Another situation which often The installation and operating characteristics of a strain influences gage selection, and leads to compromise, is the gage are affected by the following parameters, which are stock of gages at hand for day-to-day strain measurements. selectable in varying degrees: While compromises are almost always necessary, the stress analyst should be fully aware of the effects of such • strain-sensitive alloy compromises on meeting the requirements of the gage • backing material (carrier) installation.
    [Show full text]
  • Properties of Some Metals and Alloys
    Properties of Some Metals and Alloys COPPER AND COPPER ALLOYS • WHITE METALS AND ALLOYS • ALUMINUM AND ALLOYS • MAGNESIUM ALLOYS • TITANIUM ALLOYS • RESISTANCE HEATING ALLOYS • MAGNETIC ALLOYS • CON- TROLLED EXPANSION AND CON- STANT — MODULUS ALLOYS • NICKEL AND ALLOYS • MONEL* NICKEL- COPPER ALLOYS • INCOLOY* NICKEL- IRON-CHROMIUM ALLOYS • INCONEL* NICKEL-CHROMIUM-IRON ALLOYS • NIMONIC* NICKEL-CHROMIUM ALLOYS • HASTELLOY* ALLOYS • CHLORIMET* ALLOYS • ILLIUM* ALLOYS • HIGH TEMPERATURE-HIGH STRENGTH ALLOYS • IRON AND STEEL ALLOYS • CAST IRON ALLOYS • WROUGHT STAINLESS STEEL • CAST CORROSION AND HEAT RESISTANT ALLOYS* REFRACTORY METALS AND ALLOYS • PRECIOUS METALS Copyright 1982, The International Nickel Company, Inc. Properties of Some Metals INTRODUCTION The information assembled in this publication has and Alloys been obtained from various sources. The chemical compositions and the mechanical and physical proper- ties are typical for the metals and alloys listed. The sources that have been most helpful are the metal and alloy producers, ALLOY DIGEST, WOLDMAN’S ENGI- NEERING ALLOYS, International Nickel’s publications and UNIFIED NUMBERING SYSTEM for METALS and ALLOYS. These data are presented to facilitate general compari- son and are not intended for specification or design purposes. Variations from these typical values can be expected and will be dependent upon mill practice and material form and size. Strength is generally higher, and ductility correspondingly lower, in the smaller sizes of rods and bars and in cold-drawn wire; the converse is true for the larger sizes. In the case of carbon, alloy and hardenable stainless steels, mechanical proper- ties and hardnesses vary widely with the particular heat treatment used. REFERENCES Many of the alloys listed in this publication are marketed under well-known trademarks of their pro- ducers, and an effort has been made to associate such trademarks with the applicable materials listed herein.
    [Show full text]
  • 1.2 Low Temperature Properties of Materials
    1.2 Low Temperature Properties of Materials Materials properties affect the performance of cryogenic systems. Properties of materials vary considerably with temperature Thermal Properties: Heat Capacity (internal energy), Thermal Expansion Transport Properties: Thermal conductivity, Electrical conductivity Mechanical Properties: Strength, modulus or compressibility, ductility, toughness Superconductivity Many of the materials properties have been recorded and models exist to understand and characterize their behavior Physical models Property data bases (Cryocomp®) NIST: www.cryogenics.nist.gov/MPropsMAY/material%20properties.htm What are the cryogenic engineering problems that involve materials? USPAS Cryogenics Short Course Boston, MA 6/14 to 6/18/2010 1 Cooldown of a solid component Cryogenics involves cooling things to low temperature. Therefore one needs to understand the process. If the mass and type of the object and its material are known, then the m Ti = 300 K heat content at the designated temperatures can be calculated by integrating 1st Law. ~ 0 dQ Tds= = dE+ pdv The heat removed from the component is equal to its change of T = 80 K m f internal energy, ⎛ Ti ⎞ EΔ m = ⎜ CdT⎟ ⎜ ∫ ⎟ ⎝ T f ⎠ Liquid nitrogen @ 77 K USPAS Cryogenics Short Course Boston, MA 6/14 to 6/18/2010 2 Heat Capacity of Solids C(T) General characteristics: The heat capacity is defined as the change in the heat content with temperature. The heat capacity at constant volume is, 0 300 ∂E ∂s T(K) Cv = and at constant pressure,CTp = ∂T v ∂T p 3rd Law: C 0 as T 0 rms of the heat capacity are oThese two f related through the following thermodynamic relation, 2 ∂v ⎞ ∂p ⎞ Tvβ 2 1 ∂v ⎞ 1 ∂v ⎞ CCT− = − = κ= − ⎟ β= − ⎟ p v ⎟ ⎟ v ∂p ⎟ v ∂T ∂T ⎠p∂v ⎠ T κ ⎠T ⎠ p Isothermal Volume Note: C –C is small except for p v compressibility expansivity gases, where ~ R = 8.31 J/mole K.
    [Show full text]
  • Nickel and Its Alloys
    National Bureau of Standards Library, E-01 Admin. Bldg. IHW 9 1 50CO NBS MONOGRAPH 106 Nickel and Its Alloys U.S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS THE NATIONAL BUREAU OF STANDARDS The National Bureau of Standards^ provides measurement and technical information services essential to the efficiency and effectiveness of the work of the Nation's scientists and engineers. The Bureau serves also as a focal point in the Federal Government for assuring maximum application of the physical and engineering sciences to the advancement of technology in industry and commerce. To accomplish this mission, the Bureau is organized into three institutes covering broad program areas of research and services: THE INSTITUTE FOR BASIC STANDARDS . provides the central basis within the United States for a complete and consistent system of physical measurements, coordinates that system with the measurement systems of other nations, and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scientific community, industry, and commerce. This Institute comprises a series of divisions, each serving a classical subject matter area: —Applied Mathematics—Electricity—Metrology—Mechanics—Heat—Atomic Physics—Physical Chemistry—Radiation Physics—Laboratory Astrophysics^—Radio Standards Laboratory,^ which includes Radio Standards Physics and Radio Standards Engineering—Office of Standard Refer- ence Data. THE INSTITUTE FOR MATERIALS RESEARCH . conducts materials research and provides associated materials services including mainly reference materials and data on the properties of ma- terials. Beyond its direct interest to the Nation's scientists and engineers, this Institute yields services which are essential to the advancement of technology in industry and commerce.
    [Show full text]
  • Appendix C: Sensor Packaging and Installation
    176 Appendices Appendix C: Sensor Packaging and Installation Appendix C: Sensor Packaging and Installation Installation General installation considerations Once you have selected a sensor and it has been calibrated by Lake Shore, some potential Even with a properly installed temperature difficulties in obtaining accurate temperature measurements are still ahead. The proper sensor, poor thermal design of the overall installation of a cryogenic temperature sensor can be a difficult task. The sensor must be apparatus can produce measurement errors. mounted in such a way so as to measure the temperature of the object accurately without interfering with the experiment. If improperly installed, the temperature measured by the sensor Temperature gradients may have little relation to the actual temperature of the object being measured. Most temperature measurements are made on the assumption that the area of interest Figure 1—Typical sensor installation on a mechanical refrigerator is isothermal. In many setups this may not be the case. The positions of all system elements—the sample, sensor(s), and the temperature sources—must be carefully examined to determine the expected heat flow patterns in the system. Any heat flow between the sample and sensor, for example, will create an unwanted temperature gradient. System elements should be positioned to avoid this problem. Optical source radiation An often overlooked source of heat flow is simple thermal or blackbody radiation. Neither the sensor nor the sample should be in the line of sight of any surface that is at a significantly different temperature. This error source is commonly eliminated by installing a radiation shield around the sample and sensor, either by wrapping super-insulation (aluminized Mylar®) around the area, or Figure 1 shows a typical sensor installation on a mechanical refrigerator.
    [Show full text]
  • Thermocouple Materials
    NBS MONOGRAPH 40 Thermocouple Materials U.S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS UNITED STATES DEPARTMENT OF COMMERCE • Luther H. Hodges, Secretary NATIONAL BUREAU OF STANDARDS • A. V. Astin, Director Thermocouple Materials F. R. Caldwell National Bureau of Standards Monograph 40 Issued March 1, 1962 Reprinted with corrections, February 1969 For sale by the Superintendent of Documents, U.S. Government Printing Office Washington, D.C. 20402 - Price 50 cents Contents Page 1. Introduction 1 2. Bare thermocouple wires 2 2.1. Noble metals 2 a. Platinum and platinum-rliodimn alloys 2 b. Iridium versus iridium-rhodium alloys 10 c. Platinum-iridium 15 percent versus palladium 13 d. Platinel thermocouples 16 2.2. Base metals 16 a. ISA type K thermocouples 17 b. Geminol thermocouples 18 c. Iron-constantan thermocouples (ISA types Y and J) 19 d. Copper-constantan thermocouples (ISA type T) 20 e. Chromel-constantan thermocouples 21 f. Properties of base-metal thermocouple materials 21 2.3. Refractory metals 29 2.4. Carbon and carbides 35 3. Ceramic-packed thermocouple stock 37 3.1. Thermocouple wires 37 4. Conclusion 39 5. References 39 6. Appendix 42 ii Tables Page 1. Errors due to assuming the temperature of the 41. Special tolerances for different sizes of Chromel- reference junction of a Pt-Rh 30% versus Alumel thermocouple wire 17 Pt-Rh 6% thermocouple to be at 0 °C when 42. Maximum recommended operating tempera- it is at some higher temperature 3 tures for type K thermocouples 17 2. Errors due to assuming the temperature of the 43. Changes in the calibration of Chromel-Alumel reference junction of a Pt-Rh 10% versus (type K) thermocouples heated in air (elec- Pt thermocouple to be at 0 °C when it is at tric furnace) ^ 18 some higher temperature 3 44.
    [Show full text]
  • Industrial Thermocouples
    Address:W͘K͘Ždžϰϲϭϵϰϳ'ĂƌůĂŶĚ͕dyϳϱϬϰϲ Phone:ϵϳϮͲϰϵϰͲϭϱϲϲToll Free:ϭͲϴϬϬͲϴϴϵͲϱϰϳϴ Website:ǁǁǁ͘ƚŚĞƌŵŽƐĞŶƐŽƌƐ͘ĐŽŵ A Leading Manufacturer of Quality Thermocouple and RTD Assemblies Since 1972 Industrial Thermocouples Thermo Sensors Industrial thermocouples are widely used in process industry applications. Thermocouples are generally selected by determining the particular conditions under which it must perform. These conditions which have recommended wire and material selections and are grouped in types. Thermo Sensors thermocouple element types include: x Type E Chromel-Constantan Thermocouple x Type J Iron-Constantan Thermocouple x Type K Chromel-Alumel Thermocouple x Type N Nicrosil-Nisil Thermocouple x Type R Platinum-Platinum 13% Rhodium Thermocouple x Type S Platinum-Platinum 10% Rhodium Thermocouple x Type B Platinum 6% Rhodium-Platinum 30% Rhodium Thermocouple x Type T Copper- Constantan Thermocouple The wire gauge and recommended temperature ranges are of various sizes as well. Please refer to our order guide to assist in determining your needs. We can also provide technical design assistance and application suggestions. Give us a call. dŚĞƌŵŽ^ĞŶƐŽƌƐŽƌƉŽƌĂƚŝŽŶ ŽƉLJƌŝŐŚƚϮϬϭϯ ǁǁǁ͘ƚŚĞƌŵŽƐĞŶƐŽƌƐ͘ĐŽŵ WĂŐĞͮϭ Address:W͘K͘Ždžϰϲϭϵϰϳ'ĂƌůĂŶĚ͕dyϳϱϬϰϲ Phone:ϵϳϮͲϰϵϰͲϭϱϲϲToll Free:ϭͲϴϬϬͲϴϴϵͲϱϰϳϴ Website:ǁǁǁ͘ƚŚĞƌŵŽƐĞŶƐŽƌƐ͘ĐŽŵ A Leading Manufacturer of Quality Thermocouple and RTD Assemblies Since 1972 Introduction to Thermocouples The Principles and Features of Thermocouples Today's thermocouple designs are the result of many years of research and field experience. Together with quality instruments they provide the answer to thousands of temperature sensing and control problems. The Seebeck Effect Basically, a thermocouple is a closed circuit formed of two dissimilar metallic conductors to produce an electromotive force (EMF) or voltage. The voltage causes a current to flow when heat is applied to one of the junctions.
    [Show full text]