Rhine-Ruhr 1 Data Center Ecosystem in a Live Data Center Environment
Total Page:16
File Type:pdf, Size:1020Kb
GTM GERMANY | GLOBAL DATA CENTERS EMEA Rhine-Ruhr 1 Data Center Ecosystem in a live data center environment Site brochure datacenter.hello.global.ntt Site brochure | Rhine-Ruhr 1 Data Center Home to the cloud A solution for every Rhine-Ruhr, located in the federal state requirement of North Rhine-Westphalia, is the largest With a total of 2,700 sqm IT space and a highly redundant cooling systems. Rhine- metropolitan region in Germany, with maximum of 4 MW in building A, Rhine- Ruhr 1 holds multiple certifications and is a population of over 10 million. Rhine- Ruhr 1 offers a secure and highly available connected to major carrier hubs and cloud Ruhr is located at the center of the data center infrastructure for our clients networks. To validate hybrid cloud services ›European Blue Banana‹, making it very in the public sector. We provide you with and innovations faster and at lower cost, well-connected to other major European the best possible physical and technical our Technology Experience Labs provide cities and important German metropolitan infrastructure supported by 2n UPS the perfect hosted ecosystem in a live data areas. Rhine-Ruhr accounts for a large systems, n+1 generator backup, as well as center environment. amount of the German economy GDP, and is home to some important economic regions, such as Dusseldorf, Essen, Cologne and Bonn. Twelve Fortune Global 500 companies reside in the region, among them two are located in Bonn, Deutsche Post AG and Deutsche Telekom AG. Rhine-Ruhr is a highly industrialized region, and in recent years has developed important financial services and technology industries. Rhine-Ruhr 1 Data Center is NTT’s tenth data center and located within a 11,400 sqm facility situated in Bonn, about a 25 minutes drive from Cologne-Bonn Airport. After completion of both construction phases, our location will offer a total of about 5,400 sqm of high availability colocation space and total power capacity of 8 MW. 2 | © Copyright NTT Limited 2020 datacenter.hello.global.ntt Site brochure | Rhine-Ruhr 1 Data Center Secure and flexible space built to your specifications Overview of our main product offerings: Your requirements are the most important aspect of our service offering. You Fully-fitted Colocation rack choose, we deliver. Whether you select Carrier rack a building shell which you configure Cage yourself, or we construct it according to your specifications, or even if you Suite want to rent a single rack in our shared Shell and core Area environment, we can accommodate your needs. We will also ensure the space Supporting products and services Multi service interconnection platform is highly available through our years of engineering critical data centers while Cross connects maintaining high levels of security to keep Remote-hands your infrastructure and data safe. Infrastructure Data center space Power Security • 2,700 sqm of IT space in building A • off-site substations delivering 15 MVA • Service Control Center for security (5,400 sqm once fully built out) of power and operation with 24/7 fallback to • flexible colocation deployments: single • maximum client IT load of 8 MW (once Frankfurt 1 rack colocation, cages, suites, turnkey fully built out) • redundant monitoring of all critical build to suites, shell and core solutions • average power density of 1.5 kW/sqm functions underpinned by standardized security processes and the multilevel • ancillary spaces (offices, storages, and • power supply at medium level 10 kV security zone principle, secures the pre-installation rooms) available from two separate feeds rental area and the technical operation • common areas such as meeting rooms • two separate UPS systems per building • palisade fencing supported by a and catering area section (A- and B-supply) with 2n security perimeter fence to protect the redundancy data center area Cooling • redundantly designed emergency • video surveillance systems for the • high efficient chiller systems with power system with diesel generators external perimeter, plant areas, and free-cooling integrated or separated n+1 per building data halls recoolers and own-programmed, • ram-raid bollard protection in weather-dependent energy Fire protection management systems accordance to BS PAS 68:2013 • automatic digital fire alarm system on • card swipe entry/exit to all doors and • CRAH units in the suites and technical all levels with point and air aspiration rooms persons separation locks per data detectors center building • additional ground water cooling for • Very Early Smoke Detection Alarm building A • preventive risk assessment as well Systems (VESDA) in the return air path as continuous testing and training of • concurrently maintainable AHUs • firefighting system based on a nitrogen operating personnel providing fresh air pressurization and extinguishing gas system humidity control to data suites • fire protection walls to a minimum of • cold aisle containment to support high 90 minutes separation densities and maximize efficiencies • heat recovery with heating pumps for pre-heating the emergency standby power systems and offices 3 | © Copyright NTT Limited 2020 datacenter.hello.global.ntt Site brochure | Rhine-Ruhr 1 Data Center Connectivity • carrier-neutral Technology Experience Lab • carrier mix from global tier 1 supplier to • Technology spaces: Globally available facilities in productive data centers of regional supplier NTT that bring together more than 140 technology partners to enable prospects • connectivity to the major carrier hubs and clients to test and validate, but also innovate on the latest technologies. • pre-spliced dark fiber available on • Industry communities: Today, information technologies are a key enabler to demand many organizations. Our industry communities help these organizations to identify relevant technology providers and connect with helpful contacts. • redundant cabling infrastructure with diverse paths • Start-ups and Venture Capital: Many times, start-ups are major drivers when it comes to disrupting various industries. Our start-up unit brings together start- • pre-cabling to support fast cross ups, corporates and venture capitalists to enable and accelerate innovation. connect deployments • high-performance internet access • inter data center connectivity between Additional services • connectivity options to the global NTT NTT data centers for geo-redundant • client implementation network solutions • installation services • access and use of Technology Experience Labs with a worldwide • multi cloud interconnection platform • remote-hands service provided by the partner network to connect our clients to major cloud technical infrastructure on-call service service providers such as Amazon Web • facility services Services, Microsoft Azure, and Google Service Level Agreement Cloud Platform • 99.999% power uptime availability Global data center network • climate control conditions in line with • part of the NTT family of over 160 data ASHRAE guidelines centers around the world 4 | © Copyright NTT Limited 2020 datacenter.hello.global.ntt Rhine-Ruhr 1 Data Center e-shelter services GmbH Friedrich-Wöhler-Str 67 53117 Bonn Site brochure | Rhine-Ruhr 1 Data Center Germany www.e-shelter.com By car Location in Rhine-Ruhr Coming from the North via the A3 and A59 Direction motorways: irport onnln – Follow the signs to »Koblenz/Bonn/Dreieck A59 N A3 Bonn-Nordost« eeling 8 – Then take the »3-BN-Auerberg« exit onto Troidor the A565 towards »Bonn-Auerberg/Bonn- Niederael 56 Grau-Rheindorf/Bonn-Nord« – Keep right at the fork, follow the signs in iegburg the direction of »Buschdorf/Auerberg/Graur- heindorf/Hafen« and continue on »Herseler Straße« 56 – Turn left onto »An der Josefshöhe«, A555 ondor continue onto »Am Josephinum« ant – Turn left onto »Friedrich-Wöhler-Straße« ugutin ornheim A59 Coming from the South/East via the A3 ollar motorway: RHR1 – Take the A3 to »Köln/Koblenz« A3 – At motorway junction 32 Kreuz »Bonn/ Siegburg«, follow the signs to A560 »Bonn/ onn Sankt Augustin/Siegburg« – Take the A59 towards »Königswinter/Bonn« – At motorway junction 40, follow the signs to 56 A565 »Koblenz/Bonn/Dreieck Bonn- A562 A565 Nordost« – At the »3-BN-Auerberg« exit, continue itterchlic niginter towards »Bonn-Auerberg/Bonn-Grau- Rheindorf/Bonn-Nord« About the Global Data Centers division of – Continue as described above NTT Ltd. Coming from the South/East via the A61 Global Data Centers is a division of NTT Ltd. and incorporates motorway: – At motorway junction 29 »Kreuz Mecken- DPA, e-shelter, Gyron, NetMagic, NTT Indonesia Nexcenter, heim«, follow the signs to A565 »Flughafen/ RagingWire andN other NTT Communications group data center Am Josephinum Meckenheim/Bonn« divisions. Our combined global platform is one of the largest in – Head for the exit to »Bonn-Tannenbusch/ Bonn-Dransdorf« the world, with over 160 data centers spanning more than 20 – Follow »Lievelingsweg«, then turn right countries and regions including North America, Europe, Africa onto »Berta-Lungstras-Straße« and APAC. As a neutral operator, we offer access to multiple – Turn right onto »Oppelner Straße«, which Höhweg turns into »Am Josephinum« cloud providers, a largeAm Josephinum variety of internet exchanges and – Turn right onto »Friedrich-Wöhler-Straße« telecommunication network providers including our own IPv6 compliant, tier 1 global IP network. Our clients benefit from By local public transport tailored infrastructure and experience consistent best practices in design and operationsFriedrich-Wöhler-Straße across