8060A True-Rms Multimeter 300V
Total Page:16
File Type:pdf, Size:1020Kb
® This manual pertains to instruments with serial number 6851XXX or higher. 8060A True-rms Multimeter 300V Instruction Manual PN 648169 June 1997 Rev. 2, 3/00 © 1997, 1999, 2000 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision- maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven U.S.A. The Netherlands 11/99 Safety Information This meter has been designed and tested in accordance with IEC Publication 348. To ensure that the meter is used safely, follow all safety and operating instructions in this manual. If the meter is not used as described in this manual, the safety features of the meter might be impaired. • Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly. • Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Small amounts of current can be dangerous. • Do not apply more than 300V between a terminal and earth ground. • Use caution when working above 60V dc or 30V ac rms. Such voltages pose a shock hazard. • When using the probes, keep your fingers behind the finger guards on the probes. • Disconnect the live test lead before disconnecting the common test lead. • V (e.g. 300V) means volts dc or volts ac rms. Symbols The following international symbols are used in this manual: Important Safety Information in Manual AC DC Diode Test Ground Fuse Indicates Terminals At Which Dangerous Voltages May Exist Battery Table of Contents Chapter Title Page 1 Introduction and Specifications............................................ 1-1 1-1. Introduction ............................................................................. 1-3 1-2. Items Furnished with Equipment ............................................. 1-4 1-3. Specifications........................................................................... 1-4 2 Operating Instructions........................................................... 2-1 2-1. Introduction ............................................................................. 2-3 2-2. Unpacking Your Instrument..................................................... 2-3 2-3. Battery Installation or Replacement......................................... 2-3 2-4. Fuse Replacement .................................................................... 2-6 2-5. Physical Features ..................................................................... 2-7 2-6. Front Panel........................................................................... 2-7 2-7. Display................................................................................. 2-9 2-8. Signal Input Limits .................................................................. 2-10 2-9. Operation ................................................................................. 2-11 2-10. Power-On Self-Test.............................................................. 2-11 2-11. AC/DC Voltage (V) ............................................................. 2-12 2-12. True Rms Measurement ................................................... 2-12 2-13. AC-Coupled AC Measurements....................................... 2-13 2-14. Waveform Comparison and Conversion .......................... 2-14 2-15. High Impedance DC Voltage........................................... 2-15 2-16. AC/DC Current (A).............................................................. 2-17 2-17. Resistance (e)...................................................................... 2-19 2-18. Autoranging Megohms..................................................... 2-20 2-19. Autoranging Kilohms....................................................... 2-21 2-20. Conductance (S)................................................................... 2-22 2-21. Diode Test (G)................................................................... 2-24 2-22. Relative (REL)..................................................................... 2-25 2-23. Frequency (Hz) .................................................................... 2-28 2-24. Decibel (dB)......................................................................... 2-31 2-25. dBV...................................................................................... 2-32 2-26. Continuity ( )........................................................... 2-33 2-27. Initial Check-Out Procedure .................................................... 2-35 i 8060A Instruction Manual 3 Applications............................................................................ 3-1 3-1. Introduction ............................................................................. 3-3 3-2. Determining Amplifier Bandwidth .......................................... 3-3 3-3. Using the 8060A as a Q-Meter ................................................ 3-4 3-4. Measuring Amplifier Stage Gain with Relative dB ................. 3-5 3-5. General Audio Uses................................................................. 3-6 3-6. Using the 8060A to Measure Extremely Low Currents........... 3-7 3-7. Making dBm or dBW Measurements with Other Reference Impedances.............................................................................. 3-7 3-8. Changing AC dB Reference Impedances with a DC Source ... 3-9 4 Theory of Operation ............................................................... 4-1 4-1. Introduction ............................................................................. 4-3 4-2. Functional Description ............................................................ 4-3 4-3. Microcomputer .................................................................... 4-4 4-4. Measurement Acquisition Chip (MAC)............................... 4-5 4-5. A/D Conversion Cycle......................................................... 4-6 4-6. Voltage Measurement.......................................................... 4-8 4-7. Current Measurement .......................................................... 4-10 4-8. Resistance Measurement.....................................................