Q Factor Measurements on L-C Circuits
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
The Damped Harmonic Oscillator
THE DAMPED HARMONIC OSCILLATOR Reading: Main 3.1, 3.2, 3.3 Taylor 5.4 Giancoli 14.7, 14.8 Free, undamped oscillators – other examples k m L No friction I C k m q 1 x m!x! = !kx q!! = ! q LC ! ! r; r L = θ Common notation for all g !! 2 T ! " # ! !!! + " ! = 0 m L 0 mg k friction m 1 LI! + q + RI = 0 x C 1 Lq!!+ q + Rq! = 0 C m!x! = !kx ! bx! ! r L = cm θ Common notation for all g !! ! 2 T ! " # ! # b'! !!! + 2"!! +# ! = 0 m L 0 mg Natural motion of damped harmonic oscillator Force = mx˙˙ restoring force + resistive force = mx˙˙ ! !kx ! k Need a model for this. m Try restoring force proportional to velocity k m x !bx! How do we choose a model? Physically reasonable, mathematically tractable … Validation comes IF it describes the experimental system accurately Natural motion of damped harmonic oscillator Force = mx˙˙ restoring force + resistive force = mx˙˙ !kx ! bx! = m!x! ! Divide by coefficient of d2x/dt2 ! and rearrange: x 2 x 2 x 0 !!+ ! ! + " 0 = inverse time β and ω0 (rate or frequency) are generic to any oscillating system This is the notation of TM; Main uses γ = 2β. Natural motion of damped harmonic oscillator 2 x˙˙ + 2"x˙ +#0 x = 0 Try x(t) = Ce pt C, p are unknown constants ! x˙ (t) = px(t), x˙˙ (t) = p2 x(t) p2 2 p 2 x(t) 0 Substitute: ( + ! + " 0 ) = ! 2 2 Now p is known (and p = !" ± " ! # 0 there are 2 p values) p t p t x(t) = Ce + + C'e " Must be sure to make x real! ! Natural motion of damped HO Can identify 3 cases " < #0 underdamped ! " > #0 overdamped ! " = #0 critically damped time ---> ! underdamped " < #0 # 2 !1 = ! 0 1" 2 ! 0 ! time ---> 2 2 p = !" ± " ! # 0 = !" ± i#1 x(t) = Ce"#t+i$1t +C*e"#t"i$1t Keep x(t) real "#t x(t) = Ae [cos($1t +%)] complex <-> amp/phase System oscillates at "frequency" ω1 (very close to ω0) ! - but in fact there is not only one single frequency associated with the motion as we will see. -
Electrical & Electronics Measurement Laboratory Manual
DEPT. OF I&E ENGG. DR, M, C. Tripathy CET, BPUT Electrical & Electronics Measurement Laboratory Manual By Dr. Madhab Chandra Tripathy Assistant Professor DEPARTMENT OF INSTRUMENTAION AND ELECTRONICS ENGINEERING COLLEGE OF ENGINEERING AND TECHNOLOGY BHUBANESWAR-751003 PAGE 1 | EXPT - 1 ELECTRICAL &ELECTRONICS MEASUREMENT LAB DEPT. OF I&E ENGG. DR, M, C. Tripathy CET, BPUT List of Experiments PCEE7204 Electrical and Electronics Measurement Lab Select any 8 experiments from the list of 10 experiments 1. Measurement of Low Resistance by Kelvin’s Double Bridge Method. 2. Measurement of Self Inductance and Capacitance using Bridges. 3. Study of Galvanometer and Determination of Sensitivity and Galvanometer Constants. 4. Calibration of Voltmeters and Ammeters using Potentiometers. 5. Testing of Energy meters (Single phase type). 6. Measurement of Iron Loss from B-H Curve by using CRO. 7. Measurement of R, L, and C using Q-meter. 8. Measurement of Power in a single phase circuit by using CTs and PTs. 9. Measurement of Power and Power Factor in a three phase AC circuit by two-wattmeter method. 10. Study of Spectrum Analyzers. PAGE 2 | EXPT - 1 ELECTRICAL &ELECTRONICS MEASUREMENT LAB DEPT. OF I&E ENGG. DR, M, C. Tripathy CET, BPUT DO’S AND DON’TS IN THE LAB DO’S:- 1. Students should carry observation notes and records completed in all aspects. 2. Correct specifications of the equipment have to be mentioned in the circuit diagram. 3. Students should be aware of the operation of equipments. 4. Students should take care of the laboratory equipments/ Instruments. 5. After completing the connections, students should get the circuits verified by the Lab Instructor. -
The Q of Oscillators
The Q of oscillators References: L.R. Fortney – Principles of Electronics: Analog and Digital, Harcourt Brace Jovanovich 1987, Chapter 2 (AC Circuits) H. J. Pain – The Physics of Vibrations and Waves, 5th edition, Wiley 1999, Chapter 3 (The forced oscillator). Prerequisite: Currents through inductances, capacitances and resistances – 2nd year lab experiment, Department of Physics, University of Toronto, http://www.physics.utoronto.ca/~phy225h/currents-l-r-c/currents-l-c-r.pdf Introduction In the Prerequisite experiment, you studied LCR circuits with different applied signals. A loop with capacitance and inductance exhibits an oscillatory response to a disturbance, due to the oscillating energy exchange between the electric and magnetic fields of the circuit elements. If a resistor is added, the oscillation will become damped. 1 In this experiment, the LCR circuit will be driven at resonance frequencyωr = , when the LC transfer of energy between the driving source and the circuit will be a maximum. LCR circuits at resonance. The transfer function. Ohm’s Law applied to a LCR loop (Figure 1) can be written in complex notation (see Appendix from the Prerequisite) Figure 1 LCR circuit for resonance studies v( jω) Ohm’s Law: i( jω) = (1) Z - 1 - i(jω) and v(jω) are complex instantaneous values of current and voltage, ω is the angular frequency (ω = 2πf ) , Z is the complex impedance of the loop: 1 Z = R + jωL − (2) ωC j = −1 is the complex number The voltage across the resistor from Figure 1, as a result of current i can be expressed as: vR ( jω) = Ri( jω) (3) Eliminating i(jω) from Equations (1) and (3) results into: R v ( jω) = v( jω) (4) R R + j(ωL −1/ωC) Equation (4) can be put into the general form: vR ( jω) = H ( jω)v( jω) (5) where H(jω) is called a transfer function across the resistor, in the frequency domain. -
Arxiv:1704.05328V1 [Cond-Mat.Mes-Hall] 18 Apr 2017 Tuning the Mechanical Mode Frequencies by More Than Silicon Wafers
Quantitative Determination of the Mechanical Properties of Nanomembrane Resonators by Vibrometry In Continuous Light Fan Yang,∗ Reimar Waitz,y and Elke Scheer Department of Physics, Universit¨atKonstanz, 78464 Konstanz, Germany We present an experimental study of the bending waves of freestanding Si3N4 nanomembranes using optical profilometry in varying environments such as pressure and temperature. We introduce a method, named Vibrometry in Continuous Light (VICL) that enables us to disentangle the response of the membrane from the one of the excitation system, thereby giving access to the eigenfrequency and the quality (Q) factor of the membrane by fitting a model of a damped driven harmonic oscillator to the experimental data. The validity of particular assumptions or aspects of the model such as damping mechanisms, can be tested by imposing additional constraints on the fitting procedure. We verify the performance of the method by studying two modes of a 478 nm thick Si3N4 freestanding membrane and find Q factors of 2 × 104 for both modes at room temperature. Finally, we observe a linear increase of the resonance frequency of the ground mode with temperature which amounts to 550 Hz=◦C for a ground mode frequency of 0:447 MHz. This makes the nanomembrane resonators suitable as high-sensitive temperature sensors. I. INTRODUCTION frequencies of bending waves of nanomembranes may range from a few kHz to several 100 MHz [6], those of Nanomechanical membranes are extensively used in a thickness oscillation may even exceed 100 GHz [21], re- variety of applications including among others high fre- quiring a versatile excitation and detection method able quency microwave devices [1], human motion detectors to operate in this wide frequency range and to resolve [2], and gas sensors [3]. -
RF-MEMS Load Sensors with Enhanced Q-Factor and Sensitivity In
Microelectronic Engineering 88 (2011) 247–253 Contents lists available at ScienceDirect Microelectronic Engineering journal homepage: www.elsevier.com/locate/mee RF-MEMS load sensors with enhanced Q-factor and sensitivity in a suspended architecture ⇑ Rohat Melik a, Emre Unal a, Nihan Kosku Perkgoz a, Christian Puttlitz b, Hilmi Volkan Demir a, a Departments of Electrical Engineering and Physics, Nanotechnology Research Center, and Institute of Materials Science and Nanotechnology, Bilkent University, Ankara 06800, Turkey b Department of Mechanical Engineering, Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO 80523, USA article info abstract Article history: In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended Received 31 August 2009 architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance fre- Received in revised form 7 July 2010 quency shift under load. The suspended architecture is obtained by removing silicon under the sensor. Accepted 29 October 2010 We compare two sensors that consist of 195 lm  195 lm resonators, where all of the resonator features Available online 9 November 2010 are of equal dimensions, but one’s substrate is partially removed (suspended architecture) and the other’s is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-fac- Keywords: tor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. Fabrication For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied IC Resonance frequency shift load, while we achieved a 780 MHz frequency shift in the single suspended device. -
A History of Impedance Measurements
A History of Impedance Measurements by Henry P. Hall Preface 2 Scope 2 Acknowledgements 2 Part I. The Early Experimenters 1775-1915 3 1.1 Earliest Measurements, Dc Resistance 3 1.2 Dc to Ac, Capacitance and Inductance Measurements 6 1.3 An Abundance of Bridges 10 References, Part I 14 Part II. The First Commercial Instruments 1900-1945 16 2.1 Comment: Putting it All Together 16 2.2 Early Dc Bridges 16 2.3 Other Early Dc Instruments 20 2.4 Early Ac Bridges 21 2.5 Other Early Ac Instruments 25 References Part II 26 Part III. Electronics Comes of Age 1946-1965 28 3.1 Comment: The Post-War Boom 28 3.2 General Purpose, “RLC” or “Universal” Bridges 28 3.3 Dc Bridges 30 3.4 Precision Ac Bridges: The Transformer Ratio-Arm Bridge 32 3.5 RF Bridges 37 3.6 Special Purpose Bridges 38 3,7 Impedance Meters 39 3.8 Impedance Comparators 40 3.9 Electronics in Instruments 42 References Part III 44 Part IV. The Digital Era 1966-Present 47 4.1 Comment: Measurements in the Digital Age 47 4.2 Digital Dc Meters 47 4.3 Ac Digital Meters 48 4.4 Automatic Ac Bridges 50 4.5 Computer-Bridge Systems 52 4.6 Computers in Meters and Bridges 52 4.7 Computing Impedance Meters 53 4.8 Instruments in Use Today 55 4.9 A Long Way from Ohm 57 References Part IV 59 Appendices: A. A Transformer Equivalent Circuit 60 B. LRC or Universal Bridges 61 C. Microprocessor-Base Impedance Meters 62 A HISTORY OF IMPEDANCE MEASUREMENTS PART I. -
Teaching the Difference Between Stiffness and Damping
LECTURE NOTES « Teaching the Difference Between Stiffness and Damping Henry C. FU and Kam K. Leang In contrast to the parallel spring-mass-damper, in the necessary step in the design of an effective control system series mass-spring-damper system the stiffer the system, A is to understand its dynamics. It is not uncommon for a the more dissipative its behavior, and the softer the sys- well-trained control engineer to use such an understanding to tem, the more elastic its behavior. Thus teaching systems redesign the system to become easier to control, which requires modeled by series mass-spring-damper systems allows an even deeper understanding of how the components of a students to appreciate the difference between stiffness and system influence its overall dynamics. In this issue Henry C. damping. Fu and Kam K. Leang discuss the diff erence between stiffness To get students to consider the difference between soft and damping when understanding the dynamics of mechanical and damped, ask them to consider the following scenario: systems. suppose a bullfrog is jumping to land on a very slippery floating lily pad as illustrated in Figure 2 and does not want to fall off. The frog intends to hit the flower (but he simple spring, mass, and damper system is ubiq- cannot hold onto it) in the center to come to a stop. If the uitous in dynamic systems and controls courses [1]. TThis column considers a concept students often have trouble with: the difference between a “soft” system, which has a small elastic restoring force, and a “damped” system, x c which dissipates energy quickly. -
Electrical and Electronic Measurements
Contents Manual for K-Notes ................................................................................. 2 Error Analysis .......................................................................................... 3 Electro-Mechanical Instruments ............................................................. 6 Potentiometer / Null Detector .............................................................. 15 Instrument Transformer ....................................................................... 16 AC Bridges ............................................................................................. 18 Measurement of Resistance ................................................................. 21 Cathode Ray Oscilloscope (CRO) ........................................................... 25 Digital Meters ....................................................................................... 28 Q–meter / Voltage Magnifier ................................................................ 30 © 2014 Kreatryx. All Rights Reserved. 1 Error Analysis Static characteristics of measuring system 1) Accuracy Degree of closeness in which a measured value approaches a true value of a quantity under measurement. When accuracy is measured in terms of error : Guaranteed accuracy error (GAE) is measured with respect to full scale deflation. Limiting error (in terms of measured value) GAE * Full scale deflection LE Measured value 2) Precision Degree of closeness with which reading in produced again & again for same value of input quantity. 3) Sensitivity -
Lab 4: Prelab
ECE 445 Biomedical Instrumentation rev 2012 Lab 8: Active Filters for Instrumentation Amplifier INTRODUCTION: In Lab 6, a simple instrumentation amplifier was implemented and tested. Lab 7 expanded upon the instrumentation amplifier by improving circuit performance and by building a LabVIEW user interface. This lab will complete the design of your biomedical instrument by introducing a filter into the circuit. REQUIRED PARTS AND MATERIALS: Materials Needed 1) Instrumentation amplifier from Lab 7 2) Results from Prelab 3) Oscilloscope 4) Function Generator 5) DC Power Supply 6) Labivew Software 7) Data Acquisition Board 8) Resistors 9) Capacitors 10) Dual operational amplifier (UA747) PRELAB: 1. Print the Prelab and Lab8 Grading Sheets. Answer all of the questions in the Prelab Grading Sheet and bring the Lab8 Grading Sheet with you when you come to lab. The Prelab Grading Sheet must be turned in to the TA before beginning your lab assignment. 2. Read the LABORATORY PROCEDURE before coming to lab. Note: you are not required to print the lab procedure; you can view it on the PC at your lab bench. 3. For further reading consult class notes, text book and see Low Pass Filters http://www.electronics-tutorials.ws/filter/filter_2.html High Pass Filters http://www.electronics-tutorials.ws/filter/filter_3.html BACKGROUND: Active Filters As their name implies, Active Filters contain active components such as operational amplifiers or transistors within their design. They draw their power from an external power source and use it to boost or amplify the output signal. Operational amplifiers can also be used to shape or alter the frequency response of the circuit by producing a more selective output response by making the output bandwidth of the filter more narrow or even wider. -
Modified Chebyshev-2 Filters with Low Q-Factors
J KAU: Eng. Sci., vol. 3, pp. 21-34 (1411 A.H.l1991 A.D.) Modified Chebyshev-2 Filters with Low Q-Factors A. M. MILYANI and A. M. AFFANDI Department ofElectrical and Computer Engineering, Faculty ofEngineering, King Abdulaziz University, Jeddah, Saudi Arabia. ABSTRACT A modified low pass maximally flat inverse Chebyshev filter is suggested in this paper, and is shown to have improvement over previous known Chebyshev filters. The coefficients of this modified filter, using a higher order polynomial with multiplicity of the dominant pole-pair, have been determined. The pole locations and the Q factors for different orders of filters are tabulated using an optimization algorithm. 1. Introduction Recently, there has been a great deal of interest in deriving suboptimal transfer func tions with low Q dominant poles[1-3J. The suboptimality of these functions allows for low precision requirements in both active RC-filters and digital filters. It is, however, noted that the minimal order filter is not necessarily the least complex filter. In a recent article, Premoli[11 used the notion of multiplicity in the dominant poles to obtain multiple critical root maximally flat (MUCROMAF) polynomials for low pass filters. An alternative method for deriving these functions, referred to as mod ified Butterworth functions, has been presented by Massad and Yariagaddal2J . Also a new class of multiple critical root pair, equal ripple (MUCROER) filtering func tions, having higher degree than the filtering functions, has been presented by Premoli[1l. By relaxing the equal ripple conditions, Massad and Yarlagadda derived a new algorithm to find modified Chebyshev functions which have lower Qdominant polesl21 . -
Quality-Factor Considerations for Single Layer Solenoid Reactors
Quality-factor considerations for single layer solenoid reactors M. Nagel1*, M. Hochlehnert1 and T. Leibfried1 1University of Karlsruhe, Institute of Electrical Energy Systems and High-Voltage Technology Engesserstr. 11, 76131 Karlsruhe, Germany *Email: [email protected] Abstract: As it is commonly known, rating and build- are affecting the performance of existing equipment. ing a reactor is not the easiest thing to do. Numerical High frequency noise is subjected to components, pre- solutions of complex magnetic field distributions need viously only fed with clean sine waves of 50/60Hz. to be calculated to verify the design. This is getting even This noise, mainly superimposed by power elec- more challenging, when the quality-factor (Q-factor) of tronic equipment like used in Flexible AC transmission a resonator is of major importance. This problem is for systems (FACTS) build with IGBT valves, is thereby a example appearing, when building resonance circuits new stress to the equipment and poorly investigated yet. with low losses for high voltage and high frequency While in the above mentioned case, the large slew rates (HF) experiments. Coreless, one layer solenoid, or like- of the switching pulses is generating the noise, more wise, reactors are needed there to meet both frequency longer known is high frequent noise to arise by trans- and voltage requirements. Coreless because of the hys- former switching over longer lines. teresis losses of magnetic materials at high frequency In common for all the cases of high frequency noise and only one layer, due to the maximum applicable field at standard equipment is the present lack of knowledge strength per winding, which is dropping significantly at about the performance of the insulation system. -
An Efficiency Enhancement Technique for a Wireless Power
energies Article An Efficiency Enhancement Technique for a Wireless Power Transmission System Based on a Multiple Coil Switching Technique Vijith Vijayakumaran Nair and Jun Rim Choi* School of Electronics Engineering, Kyungpook National University, Buk-gu, Daegu 702-701, Korea; [email protected] * Correspondence: [email protected]; Tel.: +82-053-940-8567; Fax: +82-053-954-6857 Academic Editor: Jihong Wang Received: 15 October 2015; Accepted: 29 January 2016; Published: 3 March 2016 Abstract: For magnetic-coupled resonator wireless power transmission (WPT) systems, higher power transfer efficiency can be achieved over a greater range in comparison to inductive-coupled WPT systems. However, as the distance between the two near-field resonators varies, the coupling between them changes. The change in coupling would in turn vary the power transfer efficiency. Generally, to maintain high efficiency for varying distances, either frequency tuning or impedance matching are employed. Frequency tuning may not limit the tunable frequency within the Industrial Scientific Medical (ISM) band, and the impedance matching network involves bulky systems. Therefore, to maintain higher transfer efficiency over a wide range of distances, we propose a multiple coil switching wireless power transmission system. The proposed system includes several loop coils with different sizes. Based on the variation of the distance between the transmitter and receiver side, the power is switched to one of the loop coils for transmission and reception. The system enables adjustment of the coupling coefficient with selective switching of the coil loops at the source and load end and, thus, aids achieving high power transfer efficiency over a wide range of distances.