Chromatography for Foods and Beverages
Total Page:16
File Type:pdf, Size:1020Kb
Table of Contents Introduction Analytical Technologies Artificial Colorants Blue Dyes Caramel General Dye Method Global Method Red Dyes Sudan Dyes Yellow Dyes Natural Colorants Turmeric Flavorants Amadori Compounds Capsaicin Quinine Vanilla Miscellaneous Caffeine Choline Glucosamine Iodide Polyphosphates Chromatography for Foods and Beverages Preservatives Benzoate Nitrate and Nitrite Flavors, Colorants and Additives Sulfites Soft Drinks Analysis Applications Notebook References Analytical Methods for Food Ingredients Table of Contents Introduction Analytical Technologies Artificial Colorants Blue Dyes Caramel General Dye Method Global Method Additives Including Colorants, Red Dyes Sudan Dyes Flavorants, and Preservatives Yellow Dyes Natural Colorants Turmeric Flavorants Amadori Compounds Capsaicin Introduction Quinine Food additives are substances added to food to preserve flavor Vanilla or enhance its taste, texture, and appearance. With the advent of Miscellaneous processed foods many more additives are being used, both natural and Caffeine artificial. Additives can maintain product quality and freshness (to stop Choline Glucosamine deterioration, rancidity, and spoilage); improve or maintain the nutritional Iodide quality (to prevent diseases such as goiter, pellagra and rickets); make Polyphosphates foods more appealing (make them look and taste good); and aid in the Preservatives processing and preparation of foods. Benzoate Nitrate and Nitrite Sulfites Soft Drinks References Table of Contents Introduction Analytical Technologies Artificial Colorants Blue Dyes Caramel General Dye Method Global Method Red Dyes Analytical Technologies Sudan Dyes Yellow Dyes Natural Colorants Turmeric Flavorants Amadori Compounds Capsaicin Quinine Vanilla Miscellaneous Caffeine Choline High-Performance Glucosamine Iodide Liquid Chromatography Polyphosphates Preservatives Thermo Scientific™ Vanquish™ UHPLC System and Benzoate Thermo Scientific™ Dionex™ UltiMate™ 3000 UHPLC+ Nitrate and Nitrite Sulfites systems offer excellent chromatographic performance, Soft Drinks operational simplicity and unrivaled flexibility. Choose References from a wide range of standard and unique specialty detectors to extend your laboratory’s analytical capabilities. Table of Contents Analytical Technologies Introduction Analytical Technologies Artificial Colorants The Vanquish UHPLC System Blue Dyes Caramel General Dye Method The next generation in UHPLC innovations Delivering the new standard in UHPLC Global Method The Vanquish system takes high-end UHPLC to a new level, offering more • More powerful separations with 1500 bar of pump pressure at flow Red Dyes resolution while meeting the throughput demands of modern laboratories. rates up to 5 mL/min Sudan Dyes The system is delivers better separations, more results and easier • Industry-leading flow and gradient precision Yellow Dyes interaction, simultaneously, without compromise. • Excellent injections up to 100 μL in 0.01 μL increments Natural Colorants • Automated workflows with barcode reading for simplified setup and Turmeric tracking Flavorants • Maximum sample capacity with up to 23 well plates, or 8832 Amadori Compounds samples Capsaicin • More confident separations with a wide temperature range of 5 ºC to Quinine 120 ºC for two thermostatting modes and active column pre-heating Vanilla for improved precision Miscellaneous • UV detection with linear response up to 3000 mAu and noise levels Caffeine as low as 3 µAu Choline ™ ™ Glucosamine • Thermo Scientific LightPipe technology assures lowest peak dispersion with UV detection Iodide Polyphosphates • Available Vanquish Charged Aerosol detector for quantification of non- chromophoric compounds Preservatives Benzoate Nitrate and Nitrite Sulfites Soft Drinks References Vanquish Diode Array Detector with LighPipe technology Learn more at www.thermoscientific.com/vanquish Table of Contents Analytical Technologies Introduction Analytical Technologies Artificial Colorants UHPLC Portfolio Blue Dyes Caramel General Dye Method Global Method CDS Software Red Dyes UltiMate 3000 Basic UHPLC/MS System Solutions Sudan Dyes Chromeleon 7.2 Yellow Dyes UltiMate 3000 Standard System Natural Colorants Viper Fingertight Fitting System Turmeric Flavorants LC Columns Amadori Compounds Capsaicin Quinine Vanilla Miscellaneous Caffeine Choline Glucosamine Acclaim Trinity Iodide Columns Polyphosphates Preservatives Benzoate Accucore Columns Nitrate and Nitrite UltiMate 3000 RS and BioRS Rapid Sulfites Separation Systems Soft Drinks UltiMate 3000 XRS System Corona Charged References Aerosol Detector UltiMate 3000 RSLCnano and EASY-nLC 1000 Systems Vanquish System Table of Contents Analytical Technologies Introduction Analytical Technologies Artificial Colorants UltiMate 3000 UHPLC+ Systems Blue Dyes Caramel General Dye Method Best-in-class HPLC systems for all your chromatography needs Global Method UltiMate 3000 UHPLC+ Systems provide excellent chromatographic performance while maintaining easy, reliable operation. The basic and standard Red Dyes analytical systems offer ultra HPLC (UHPLC) compatibility across all modules, ensuring maximum performance for all users and all laboratories. Sudan Dyes Covering flow rates from 20 nL/min to 10 mL/min with an industry-leading range of pumping, sampling, and detection modules, UltiMate 3000 Yellow Dyes UHPLC+ Systems provide solutions from nano to semipreparative, from conventional LC to UHPLC. Natural Colorants Superior chromatographic performance Turmeric • UHPLC design philosophy throughout nano, standard analytical, and rapid separation liquid chromotography (RSLC) Flavorants • 620 bar (9,000 psi) and 100 Hz data rate set a new benchmark for basic and standard analytical systems Amadori Compounds Capsaicin • RSLC systems go up to 1000 bar and data rates up to 200 Hz Quinine • ×2 Dual System for increased productivity solutions in routine analysis Vanilla • Fully UHPLC compatible advanced chromatographic techniques Miscellaneous • Thermo Scientific™ Dionex™ Viper™ and nanoViper™ fingertight fittings—the first truly universal, fingertight fitting system even at UHPLC pressures Caffeine Choline Glucosamine Iodide Polyphosphates Preservatives Benzoate Nitrate and Nitrite Sulfites Soft Drinks References Learn more at www.thermoscientific.com/liquidchromatography Table of Contents Analytical Technologies Introduction Analytical Technologies Artificial Colorants UltiMate 3000 UHPLC+ Systems Blue Dyes Caramel General Dye Method We are uniquely focused on making UHPLC technology available to all users, all laboratories, and for all analytes. Global Method Red Dyes Sudan Dyes Yellow Dyes Natural Colorants Turmeric Flavorants Amadori Compounds Capsaicin Quinine Vanilla Miscellaneous Rapid Separation LC Systems Standard LC Systems The extended flowpressure footprint of the RSLC system provides the performance for ultrafast Choose from a wide variety of standard LC systems for demanding LC applications at nano, Caffeine high-resolution and conventional LC applications. capillary, micro, analytical, and semipreparative flow rates. Choline Glucosamine Iodide Polyphosphates Preservatives Benzoate Nitrate and Nitrite Sulfites Soft Drinks References RSLCnano Systems Basic LC Systems The Rapid Separation nano LC System (RSLCnano) provides the power for high resolution and UltiMate 3000 Basic LC Systems are UHPLC compatible and provide reliable, high performance fast chromatography in nano, capillary, and micro LC. solutions to fit your bench space and your budget. Table of Contents Analytical Technologies Introduction Analytical Technologies Artificial Colorants Advanced Detection Capabilities Blue Dyes Caramel General Dye Method Charged Aerosol Detection Global Method Charged Aerosol Detection provides near universal detection independent Red Dyes of chemical structure for non- or semi-volatile analytes with HPLC and Sudan Dyes UHPLC. Thermo Scientific™ Dionex™ Corona™ Veo™ and Vanquish Yellow Dyes Charged Aerosol detectors are ideally suited as a primary detector for any laboratory, while providing complementary data to UV or MS methods. Natural Colorants No other LC detector available today can match the performance of a Turmeric Corona Veo detector. Flavorants • High sensitivity – single-digit nanogram on column Amadori Compounds Corona Veo Charged Aerosol Detector Capsaicin • Consistent response – independent of chemical structure Quinine • Wide dynamic range – to four orders of magnitude or greater Vanilla • Simple to use – easy to integrate with any HPLC/UHPLC system Miscellaneous Charged aerosol detectors give the simplicity, reproducibility and Caffeine performance required for a full range of applications from basic research Choline to manufacturing QC/QA. With charged aerosol detection you get Glucosamine predictable responses to measure analytes in direct proportion to their Iodide relative amounts for quantitation without actual standards. Polyphosphates This detector offers the flexibility to use reversed-phase gradients, as well Preservatives as normal phase and HILIC modes of separation on any LC system. Benzoate And, in many cases eliminates the need for derivatization or sample pre- Nitrate and Nitrite treatment to provide real dilute-and-shoot simplicity. Sulfites Soft Drinks References Vanquish system with Charged Aerosol Detector Learn more at www.thermoscientific.com/CAD Table of Contents Analytical Technologies Introduction Analytical Technologies Artificial Colorants Advanced Detection Capabilities Blue Dyes Caramel General