2642.145.01 COPYRIGHT NOTICE: GENERAL NOTES: These drawings and specifications are copyrighted and subject to copyright MARK MANUFACTURER MODEL UNIT SUPPLY COOLING COIL MIN. ABS. MIN. MCA MOCP V/PH DISC. DIMENSIONS WEIGHT FURNISHED BY INSTALLED BY NOTES protection as an "architectural work" PRIOR TO SUBMITTING BID, MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE TYPE FAN CFM MIN ESP MSAV DRIVE REFR. TH SH EAT LAT MIN. OUTPUT EFF. NOM. INPUT EAT MIN. NO. O/A MIN. EFFICIENCY TYPE (LxWxH) LBS under sec. 102 of the copyright act, AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. TYPE HP (IN) (Y/N) (BELT/DIRECT) TYPE (MBH) (MBH) DB WB DB WB (MBH) (%) (MBH) STAGES CFM O/A CFM REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR 17 U.S.C. As amended January 2003. THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ETC. ARE RTU-1 LENNOX LGH060H SINGLE ZONE FC 2200 1 1 Y DIRECT R-410A 60.4 50.4 77.2 64.2 55.1 54.6 120 80 150 66.0 2 350 N/A 12.7 EER 15 20 460/3 FUSED 86x47x47 804 DEVELOPER DEVELOPER A-K, M-Q,R,U,W,Y The protection includes, without NOTE: NECESSARILY USED ON THE DRAWINGS. ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE DOCUMENTS. NOTIFY ARCHITECT, ENGINEER limitation, the overall form, RTU-2 LENNOX LGH150S SINGLE ZONE FC 4400 3 1 Y BELT R-410A 130.6 103.3 74.0 62.0 51.5 51.1 104 80 130 72.0 2 0 N/A 11.0 EER 27 30 460/3 FUSED 102x61x47 1291 DEVELOPER DEVELOPER A-K, M-Q,U,W,Y arrangement and composition of AND/OR OWNER OF CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. RTU-3 LENNOX LGH072H SINGLE ZONE FC 2100 2 0.9 Y DIRECT R-410A 70.3 54.1 77.5 64.5 52.6 52.6 120 80 150 65.0 2 350 N/A 12.0 EER 15 20 460/3 FUSED 86x47x47 739 DEVELOPER DEVELOPER A-K, M-Q,U,W,Y spaces, and elements of the design. Under such protection, unauthorized EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND RTU-4 LENNOX LGH060H SINGLE ZONE FC 2000 1 1 Y DIRECT R-410A 58.2 46.5 75.4 63.0 53.0 52.6 86 80 108 70.5 2 130 N/A 12.7 EER 15 20 460/3 FUSED 86x47x47 793 DEVELOPER DEVELOPER A-K, M-Q,U,W-Y CD CONDENSATE DRAIN (CD) use of these drawings and MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. FIELD VERIFY EXISTING specifications may result in cessation ACD AUXILIARY CONDENSATE DRAIN (ACD) CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND NOTES: of construction, building seizure, and / DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO or monetary liability. RL LIQUID (RL) CONSTRUCTION. A. PROVIDE DIFFERENTIAL WITH BAROMETRIC RELIEF . RD REFRIGERANT DISCHARGE (HOT GAS) (RD) B. EQUIPMENT SIZED FOR 110°F AMBIENT TEMPERATURE. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES C. PROVIDE 2", 30% EFFICIENT PLEATED THROWAWAY AIR FILTERS. RS REFRIGERANT SUCTION (RS) TO ENSURE A NEAT AND ORDERLY INSTALLATION. INSTALL DUCTWORK AS TIGHT TO D. SPECIFIED FAN ESP ACCOUNTS FOR LOSSES EXTERNAL TO UNIT. HWS HEATING HOT WATER SUPPLY (HWS) STRUCTURE AS POSSIBLE. COORDINATE WITH OTHER TRADES TO AVOID CONFLICTS. COORDINATE INSTALLATION OF DUCTWORK TO AVOID CONFLICTS WITH ELECTRICAL E. PROVIDE AES INDUSTRIES INSULATED ROOF CURB WITH MINIMUM HEIGHT OF 14". AES CONTACT: PAUL LEDBETTER, (800) 786-0402 EXT. 309, [email protected] HWR HEATING HOT WATER RETURN (HWR) PANELS, LIGHTING FIXTURES, ETC. ANY MODIFICATIONS REQUIRED DUE TO LACK OF F. TEMPERATURE SENSOR WIRED TO EMS PANEL FOR 7-DAY PROGRAMMABLE CONTROLS WITH STAGED HEATING AND COOLING CAPABILITY COORDINATION WILL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR AT AS REQUIRED FOR OPERATION OF AUXILIARY HEATING, COOLING AND ECONOMIZER CONTROLS. CWS SUPPLY (CWS) NO EXTRA COST TO THE OWNER. G. SUPPLY AND RETURN AIR DUCT SMOKE DETECTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. CWR CHILLED WATER RETURN (CWR) H. PROVIDE FACTORY MOUNTED DISCONNECT. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW HS SUPPLY (HS) J. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. INSTALLATION DURING WORK. REPAIR DAMAGE CAUSED DURING CONSTRUCTION AT K. COORDINATE SIZE OF CONDUCTOR TERMINATION LUGS WITH CONDUCTOR SIZES SHOWN ON ELECTRICAL DRAWINGS. HR HEAT PUMP RETURN (HR) NO EXTRA COST TO THE OWNER. L. PROVIDE HOT GAS REHEAT COIL FOR DEHUMIDIFICATION CONTROL SEQUENCE. M. PROVIDE UNPOWERED DUPLEX RECEPTACLE MOUNTED ON UNIT WITH THRU-THE-BASE POWER SUPPLY. FIELD WIRING PROVIDED BY ELECTRICAL CONTRACTOR. LPS LOW PRESSURE STEAM SUPPLY (LPS) ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE N. COOLING COIL LAT IS LEAVING AIR TEMPERATURE OF COIL. LPC LOW PRESSURE STEAM CONDENSATE (LPC) PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. TEMPERATURE SENSORS, , SENSORS AND CARBON DIOXIDE O. SELECT EQUIPMENT FOR ELEVATION OF 950 FEET ABOVE SEA LEVEL. 1220 Marshall Street NE 1220 Marshall 55413 MN Minneapolis, main 612.677.7100 fax 612.677.7499 Ltd. EXISTING PIPING TO BE REMOVED SENSORS SHALL BE FURNISHED BY SPROUTS AND INSTALLED BY P. PROVIDE HEATER TO MEET OR EXCEED SCHEDULED MINIMUM MBH OUTPUT. NOMINAL INPUT IS BASED ON LISTED MANUFACTURER'S STANDARD PRODUCT. Architects RSP COORDINATE EQUIPMENT GAS LOAD WITH PLUMBING CONTRACTOR IF DIFFERENT FROM THAT SCHEDULED. EXISTING PIPING TO REMAIN CONTACTOR, UNLESS NOTED OTHERWISE ON DRAWINGS. Q. PROVIDE WITH HINGED PANELS. DIRECTION OF FLOW NEW MECHANICAL EQUIPMENT AND DUCTWORK ARE SHOWN AT APPROXIMATE R. MECHANICAL CONTRACTOR SHALL INSTALL LENNOX MODEL #56L80 TEMPERATURE SENSOR WITH OCCUPANT OVERRIDE, STAGED HEATING AND COOLING CAPABILITY AS REQUIRED FOR OPERATION BALL VALVE LOCATIONS. FIELD MEASURE FINAL DUCTWORK LOCATIONS PRIOR TO FABRICATION OF AUXILIARY HEATING, COOLING AND ECONOMIZER CONTROLS. REFER TO ELECTRICAL SHEETS FOR EMS CONTROL DIAGRAM. AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK WITHIN THE S LENNOX FURNISHED AND MECHANICAL CONTRACTOR INSTALLED COLUMN MOUNTED , , AND AVERAGING SENSOR. CONTROL VALVE AVAILABLE SPACE. VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET T. ROOFTOP UNIT INTERLOCKED WITH HOOD EXHAUST FAN TO PROVIDE MAKE-UP AIR WHEN HOOD MOUNTED EXHAUST FAN SWITCH IS ENERGIZED. INTERLOCK SHALL BE PROVIDE BY EMS CONTRACTOR. SEE FAN SCHEDULE FOR CLARIFICATION. MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND THREE-WAY CONTROL VALVE U. PROVIDE FACTORY INSTALLED SUPPLY FAN PROVING SWITCH. PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. V. ABS. MIN. O/A IS THE ABSOLUTE MINIMUM OUTSIDE AIR CFM USING VENTILATION RESET OR DEMAND CONTROL VENTILATION. SHUTOFF VALVE REFER TO ARCHITECTURAL DRAWINGS FOR RELATED CONSTRUCTION DETAILS AS W. PROVIDE WITH MANUFACTURER STANDARD THRU-THE-BASE WIRING FOR MAIN POWER SUPPLY AND GENERAL CONVENIENCE RECEPTACLE. CHECK VALVE APPLICABLE TO THE HVAC SYSTEM. VERIFY CHASES AND PENETRATIONS SHOWN ON X. PROVIDE FUSED DISCONNECT SWITCH WITH UNIT. BALANCING VALVE WITH PRESSURE PORTS ARCHITECTURAL DRAWINGS THAT ARE INTENDED FOR DUCTWORK AND PIPING MEET Y. LENNOX NATIONAL ACCOUNTS SERVICES TO PROVIDE SITE SET-UP AND START-UP SERVICES. REQUIREMENTS. TRIPLE DUTY VALVE WITH PRESSURE PORTS WATER METER COORDINATE LOCATION OF ROOF MOUNTED HVAC EQUIPMENT AND ROOF PENETRATIONS WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. STRAINER SOLENOID VALVE MEASURES: PROTECT INSIDE OF (INSTALLED AND DELIVERED) DUCTWORK AND HVAC UNITS FROM EXPOSURE TO DUST, DIRT, PAINT AND PRESSURE GAUGE MOISTURE. REPLACE INSULATION THAT HAS GOTTEN WET AT ANY TIME DURING MARK MANUFACTURER MODEL SUPPLY FAN OAT (DB/WB) MIN. ABS. HEAT EXCHANGER MCA MOCP V/PH DISC. DIMENSIONS WEIGHT FURNISHED BY INSTALLED BY NOTES DEHUMID CONSTRUCTION, DRYING THE INSULATION IS NOT ACCEPTABLE. SEAL ANY TEARS OR FAN CFM MIN ESP VFD (0.4% O/A MIN. MIN. OUTPUT EFF. NOM. INPUT EAT MIN. NO. TYPE (LxWxH) LBS THERMOMETER (LB/HR) JOINTS OF INTERNAL FIBERGLASS INSULATION. REMOVE DEBRIS FROM TYPE HP (IN) (Y/N) DEHUMID.) CFM O/A CFM (MBH) (%) (MBH) STAGES PRESSURE AND TEMPERATURE TEST PLUG CEILING/RETURN AIR PLENUM INCLUDING DUST. AN INDEPENDENT, PROFESSIONAL DHU-1 MUNTERS HCUc6030 BAF 10,000 15 1.25 N 95/75 190 2,025 2,025 320 80 400 68 2 93 100 460/3 FUSED 173x96x72 5415 DEVELOPER MECH. CONTRACTOR A-O DUCT CLEANING COMPANY SHALL VACUUM CLEAN ANY DUCTWORK CONNECTED TO UNION HVAC UNITS THAT WERE OPERATED DURING THE CONSTRUCTION PERIOD BEFORE NEW FLANGE CONNECTION FILTERS ARE INSTALLED AND PRIOR TO TURNING SYSTEM OVER TO THE OWNER. NOTES: ELBOW UP INSTALL DUCTWORK PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE A. PROVIDE FUSED DISCONNECT SWITCH WITH UNIT. ELBOW DOWN SHOWN OR NOTED. B. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. C. PROVIDE AES INDUSTRIES INSULATED ROOF CURB WITH MINIMUM HEIGHT OF 14". AES CONTACT: PAUL LEDBETTER, (800) 786-0402 EXT. 309, [email protected] TEE UP OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT, DUCTWORK SHALL BE D. COORDINATE SIZE OF CONDUCTOR TERMINATION LUGS WITH CONDUCTOR SIZES SHOWN ON ELECTRICAL DRAWINGS. TEE DOWN FASTENED TO BUILDING JOISTS OR BEAMS. DO NOT ATTACH HANGERS AND E. PROVIDE UNPOWERED DUPLEX RECEPTACLE MOUNTED ON UNIT WITH THRU-THE-BASE POWER SUPPLY. FIELD WIRING PROVIDED BY ELECTRICAL CONTRACTOR. SUPPORTS TO THE ABOVE FLOOR SLAB OR ROOF. REDUCER F. RETURN AIR DUCT SMOKE DETECTORS SHALL BE FURNISHED INTEGRAL WITH UNIT AND SUPPLY AIR SMOKE DETECTOR SHIPPED LOOSE AND FIELD INSTALLED. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT G. SPECIFIED FAN ESP ACCOUNTS FOR DUCT LOSSES EXTERNAL TO UNIT. ACCESS PANELS/DOORS TO ENABLE SERVICE OF EQUIPMENT AND/OR FILTER H. SELECT EQUIPMENT FOR ELEVATION OF 950 FEET ABOVE SEA LEVEL. REPLACEMENT. J. PROVIDE FACTORY INSTALLED SUPPLY FAN PROVING SWITCH. NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. K. PROVIDE MODULATING OUTSIDE AIR AND RETURN AIR DAMPERS FOR CONTROL BY EMS FOR DEMAND CONTROL VENTILATION. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH L. MECHANICAL CONTRACTOR TO INSTALL POWERWALL SUPPLIER FURNISHED TEMPERATURE SENSOR, HUMIDITY SENSOR AND CO2 SENSOR. REFER TO ELECTRICAL SHEETS FOR EMS CONTROL DIAGRAM. RECEIVE INSULATION OR LINER. THE CONTRACT SPECIFICATIONS. M. COOLING COIL 284.5 MBH TOTAL, 166.7 SENSIBLE. N. PROVIDE HEATER TO MEET OR EXCEED SCHEDULED MINIMUM MBH OUTPUT. NOMINAL INPUT IS BASED ON LISTED MANUFACTURER'S STANDARD PRODUCT. COORDINATE EQUIPMENT GAS LOAD WITH PLUMBING CONTRACTOR IF DIFFERENT FROM THAT SCHEDULED. EXISTING DUCTWORK OR EQUIPMENT TO REMAIN COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS, REGISTERS O. UNIT SHALL BE INTERLOCKED WITH EF-1 & EF-4 AND WITH THE SUPPLIER TO MEET THE CEILING, WALL AND DUCT

EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED INSTALLATION REQUIREMENTS. VESTAVIA35216 HILLS,AL

ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS AND GRILLES AS REQUIRED TO BRANCH DUCT WITH 45° RECTANGLE-ROUND BRANCH ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS. FITTING AND MANUAL VOLUME DAMPER LOCATE AND SET THERMOSTATS AT LOCATIONS SHOWN ON PLANS. VERIFY EXACT ELBOW WITH TURNING VANES LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. INSTALL DEVICES 48" AFF TO

MEET ADA REQUIREMENTS UNLESS NOTED OTHERWISE ON PLANS. PROVIDE 1031 MONTGOMERY101 SUITE HIGHWAY, INSULATED BACKING FOR THERMOSTATS MOUNTED ON EXTERIOR BUILDING WALLS. MARK SERVICE MANUFACTURER MOUNTING MODEL CFM ESP DRIVE MIN. FAN VFD ELECTRICAL WEIGHT FURNISHED BY INSTALLED BY NOTES INSTALL WIRING IN CONDUIT PROVIDED BY DIVISION 16. (EA, RA, SA) (IN) (BELT/DIRECT) HP RPM (Y/N) V/PH DISC. TYPE (LBS) RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP EF-1 EA GREASEMASTER ROOF GMDU50H 1200 1.0 BELT 0.5 1560 N 115/1 NON-FUSED 66 MECH. CONTRACTOR MECH. CONTRACTOR B-F COORDINATE THE LOCATION AND ELEVATION OF WALL-MOUNTED DEVICES WITH RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN PRESENTATION BOARDS, DISPLAY CABINETS, SHELVES OR OTHER COMPONENTS EF-2 EA GREASEMASTER ROOF GMDR30H 500 0.5 DIRECT 0.25 1114 N 115/1 NON-FUSED 49 MECH. CONTRACTOR MECH. CONTRACTOR A-C,F SHOWN ON THE ARCHITECTURAL DRAWINGS THAT ARE TO BE INSTALLED UNDER EF-3 EA GREASEMASTER PLENUM CFA 700GM 550 0.5 DIRECT 0.42 902 N 115/1 NON-FUSED 45 MECH. CONTRACTOR MECH. CONTRACTOR B-C, G-H SUPPLY AIR DUCT UP OTHER DIVISIONS. CONTRACTOR WILL NOT BE REIMBURSED FOR RELOCATION OF WALL-MOUNTED DEVICES CAUSED BY A LACK OF COORDINATION. EF-4 EA GREASEMASTER ROOF GMDU50H 690 1.0 DIRECT 0.5 1366 N 115/1 NON-FUSED 63 MECH. CONTRACTOR MECH. CONTRACTOR B-C,F,J SUPPLY AIR DUCT DOWN PROVIDE A MANUAL BALANCING DAMPER IN EACH BRANCH DUCT TAKEOFF FROM NOTES: MAIN SUPPLY, RETURN, OUTDOOR AND EXHAUST AIR DUCTS. EQUIPMENT WITH FLEXIBLE DUCT CONNECTION A. PROVIDE WITH MINIMUM 8" HIGH ROOF CURB, BIRDSCREEN AND BACKDRAFT DAMPER. PROVIDE A PREFABRICATED 45 DEGREE, HIGH EFFICIENCY, RECTANGULAR/ROUND BRANCH DUCT TAKEOFF FITTING WITH MANUAL BALANCING DAMPER AND LOCKING B. DIVISION 16 CONTRACTOR TO FURNISH DISCONNECT SWITCH. 10" CSD-1 300 CFM C. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER QUADRANT FOR BRANCH DUCT CONNECTIONS AND TAKE-OFFS TO INDIVIDUAL DIFFUSERS, REGISTERS AND GRILLES. D. INTERLOCK FAN OPERATION WITH ROOFTOP UNIT RTU-1. REVISION: E. PROVIDE WITH MINIMUM 12" HIGH ROOF CURB, VENTED ROOF CURB EXTENSION FOR 40" MINIMUM DISCHARGE HEIGHT ABOVE ROOF SURFACE, GREASE TRAP AND DRAIN CONNECTION, HINGE KIT, MANUAL VOLUME DAMPER BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECK SIZE AND INTEGRAL MOTOR OVERLOAD PROTECTION. UNLESS OTHERWISE NOTED. SQUARE TO ROUND TRANSITION F. PROVIDE WITH VARIABLE SPEED CONTROLLER. G. PROVIDE HANGING VIBRATION ISOLATORS AND INTERNAL MOUNTED SPEED CONTROLLER. RIGID DUCTWORK INSULATION: PROVIDE 3/4 LB DENSITY, 3" (R-8) THICK, INSULATION DUCT MOUNTED SMOKE DETECTOR H. FAN IS INTENDED TO RUN 24 HOURS A DAY. WRAP ON RIGID ROUND, CONCEALED (NON-CONDITIONED SPACE), SUPPLY AND (SD=SUPPLY/RD=RETURN) RD RETURN AIR DUCTS AND ON OUTSIDE AIR DUCTS. FURNISH AND INSTALL 1-1/2 LB J. INTERLOCK FAN OPERATION WITH ROOFTOP UNIT RTU-2. DENSITY, 2" (R-8) INTERNAL DUCT LINER ON ROUND SUPPLY AND RETURN AIR DUCTS AVERAGING SENSOR WITHIN 10'-0" OF ROOFTOP UNIT DUCT DROP LOCATED WITHIN THE MAIN SALES AREA. FURNISH AND INSTALL 1-1/2 LB DENSITY, 2" (R-8) THICK INTERNAL DUCT LINER FIRE SMOKE DAMPER CARBON DIOXIDE SENSOR ON RECTANGULAR CONCEALED (NON-CONDITIONED SPACE), SUPPLY AND RETURN AIR DUCTS. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDE AIRFLOW DIMENSIONS, INCREASE SHEET METAL SIZES ACCORDINGLY. EXHAUST AREA/EQUIPMENT EXHAUST TOTALS SMOKE DAMPER HUMIDITY SENSOR MARK MANUFACTURER MODEL FACE MOUNTING FACE SIZE MAX. MAX. PRESS. NOTES EQUIPMENT SERVED (CFM) (CFM) TYPE LOCATION (IN) NC DROP (IN. W.C.)

PROVIDE THERMAFLEX TYPE M-KE OR G-KM, FLEXMASTER TYPE 8, OR APPROVED CONSULTING ENGINEER VOLUME DAMPER PULL STATION EQUAL FLEXIBLE DUCTWORK. FLEXIBLE DUCTWORK SHALL BE LISTED UNDER UL 181 EF-1 Deli Prep Hood exhaust 1200 SD-1 TITUS MCD MODULAR GYP. 12x12 25 0.1 A,B,C,D,G,H,J fax: (763)367-7601 fax: tel:(763)367-7600 Structural - Mechanical - Electrical - Mechanical - Structural Engineers Consulting 9100 49th Ave. North Ave. 49th 9100 Certificate of Authorization # CA - 4208 E 4208 - CA # Authorization of Certificate AS CLASS 1 AIR DUCT AND BE PROVIDED WITH INTEGRAL R-8, 3/4 LB DENSITY Inc. Associates, & Nelson-Rudie 55428 MN Minneapolis, EF-2 Men / Women Restroom Exhaust 500 SD-2 TITUS MCD MODULAR LAY-IN 24x24 25 0.1 A,B,C,D,G,H MOTORIZED DAMPER TEMPERATURE SENSOR FIBERGLASS INSULATION. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5'-0" IN LENGTH AND SHALL BE INSTALLED AND SUPPORTED TO AVOID SHARP BENDS AND SAGGING. EF-3 Scan Room Scan Room Server Exhaust N/A SD-3 TITUS MCD MODULAR GYP. 24x24 25 0.1 A,B,C,D,G,H,J,L BACKDRAFT DAMPER HH HUMIDISTAT SD-4 TITUS DL DRUM DUCT SEE PLAN 25 0.1 A,E,F,J,K EXP: PROVIDE EQUIPMENT VENTS PER EQUIPMENT MANUFACTURERS RECOMMENDATIONS EF-4 Deli Prep Oven Exhaust 690 12-31-15 AND EQUIPMENT SPECIFICATIONS. KEEP PENETRATIONS THROUGH ROOF A MINIMUM SD-5 TITUS 300FS LOUVERED DUCT NECK +1-3/4 25 0.1 A,C,E,F,J,K T 2,390 OF 10'-0" FROM HVAC EQUIPMENT FRESH AIR INLETS AND 2'-0" FROM ROOF RG-1 TITUS 350RL LOUVERED GYP. 12x12 25 0.1 A,C,D,G,H,M PARAPETS. OUTDOOR AIR AREA/EQUIPMENT SUPPLY AIR DESIGN DCV PERCENT EQUIPMENT SERVED (CFM) OA (CFM) OA (CFM) OA/SA RG-2 TITUS 350RL LOUVERED LAY-IN 24x24 25 0.1 A,C,D,G,H PROFESSIONAL AFF ABOVE FINISHED FLOOR MIN MINIMUM PROVIDE TYPE I GREASE HOOD EXHAUST DUCTWORK OF MINIMUM 16 GAUGE BLACK RTU-1 Offices / Breakroom 2,200 350 N/A 15.9% RG-3 TITUS 350RL LOUVERED GYP. 24x24 25 0.1 A,C,D,G,H,M BAS SYSTEM NC NOISE CRITERIA IRON WITH LIQUID TIGHT WELDS, WITH ACCESS PANELS FOR GREASE CLEANING AS REQUIRED BY NFPA 96 AND LOCAL CODES. SLOPE DUCT BACK TOWARDS HOOD AT BD BACKDRAFT DAMPER OA OUTSIDE AIR RTU-2 Deli Prep 4,400 0 N/A 0.0% EG-1 TITUS 350RL LOUVERED GYP. 12x12 25 0.1 A,C-E,G,H,J MINIMUM OF 1/4" PER LINEAL FOOT MAINTAINING 18" CLEARANCE TO COMBUSTIBLE CFM CUBIC FEET PER MINUTE RA RETURN AIR TG-1 TITUS 350RL LOUVERED GYP. 24x24 25 0.1 A,C,D,G,H,M MATERIALS. INSTALL GREASE DUCTS IN AN APPROVED FIRE-RATED ENCLOSURE RTU-3 Receiving 2,100 350 N/A 16.7% DDC DIRECT DIGITAL CONTROL SA SUPPLY AIR 03-27-15 SEPARATED FROM THE EXHAUST DUCT BY A MINIMUM OF 6" AND MAXIMUM OF 12". TG-2 TITUS 350RL LOUVERED LAY-IN 24x24 25 0.1 A,C,D,G,H DATE: DX DIRECT EXPANSION SD SMOKE DUCT DETECTOR VENTILATE ENCLOSURE TO THE OUTSIDE AIR IF REQUIRED BY CODE. AS AN OPTION, IF RTU-4 Stock Area / Restrooms 2,000 130 N/A 6.5% EA EXHAUST AIR TFA TO FLOOR ABOVE APPROVED BY LOCAL CODES, PROVIDE AN APPROVED WRAP SYSTEM IN LIEU OF THE TG-3 TITUS 350RL LOUVERED WALL NECK +1-3/4 25 0.1 A,C,E,G DHU-1 MAIN SALES 10,000 2,025 1,760 20.3% FFA FROM FLOOR ABOVE TFB TO FLOOR BELOW RATED DUCT ENCLOSURE SYSTEM. DUCT WRAP SYSTEM SHALL MEET UL NOTES: FFB FROM FLOOR BELOW TYP TYPICAL REQUIREMENTS FOR GREASE DUCT ENCLOSURES. TOTAL AIRFLOW 20,700 2,855 13.8% MIN. O/A 2,855 A. NECK SIZE SHOWN ON DRAWINGS. IN WC INCHES OF WATER COLUMN UC UNDERCUT DCV O/A 2,590 PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND *CO2 DEMAND CONTROL VENTILATION (DCV) IS PROVIDED. B. 4-WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. MAX MAXIMUM UNO UNLESS NOTED OTHERWISE BALANCING. AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. MBH 1000 BTU PER HOUR W/ WITH TOTAL POSITIVE AIR FLOW (DCV) 200 C. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. MC MECHANICAL CONTRACTOR W/O WITHOUT D. BAKED ENAMEL FINISH, WHITE TO MATCH CEILING COLOR. PLACEMENT, DUCTING AND STARTUP OF THE MECHANICAL UNITS SHALL BE BY THE PERCENT POSITIVE AIR FLOW (DCV) 7.7% MECHANICAL CONTRACTOR. E. FRONT BLADES PARALLEL TO LONG DIMENSION. F. DOUBLE DEFLECTION BARS SHALL BE ADJUSTABLE. TOTAL POSITIVE AIR FLOW 465 ALL EXPOSED DUCT WORK SHALL BE INSTALLED AS TIGHT TO ROOF STRUCTURE AS G. PROVIDE NECK FOR DUCT CONNECTION. MECHANICAL (AFF, AFG, UNLESS NOTED OTHERWISE) POSSIBLE. PERCENT POSITIVE AIR FLOW 16.3% H. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. THERMOSTATS (USER ADJUSTABLE) 72" J. PROVIDE OPPOSED BLADE DAMPER ADJUSTABLE FROM FACE OF DEVICE. EITHER WHEN STORED OR MOVED INTO ROUGH FRAME, HVAC EQUIPMENT OPENINGS K. ALUMINUM CONSTRUCTION AND FINISH. AND DUCTS SHOULD BE PROTECTED AND PROTECTION MAINTAINED UNTIL FINAL CONTROLS (CENTERLINE) 72" L. PROVIDE RAPID MOUNT FRAME FOR GYP. CEILING INSTALLATION. STARTUP OF THE SYSTEM. M. PROVIDE PF MOUNT FRAME FOR GYP. CEILING INSTALLATION. ALL HVAC UNITS INSTALLED AND OPERATIONAL DURING CONSTRUCTION AND UP TO THE POINT OF OCCUPANCY SHALL BE INSTALLED WITH MERV 8 FILTERS. MECHANICAL PLAN CALLOUT MODEL MIN DAMPER MARK MANUFACTURER MODEL COOLING STAGE (CFM) VENT. HEATING POSITION REFER TO OUTDOOR AIR SCHEDULE, THIS SHEET, FOR VENTILATION INFORMATION. MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED FIRST SECOND THIRD FOURTH (CFM) (CFM) SETTINGS (QTY) AND INSTALLED UNLESS NOTED OTHERWISE) RTU-1 LENNOX LGH060H 1100 2200 N/A N/A 750 2200 2 MARK SERVICE AREA MANUFACTURER MODEL UNIT SPECS V/PH/HZ NOTES RTU-2 LENNOX LGH150S 2200 4400 N/A N/A 1500 4400 2 LENGTH MAX. MOTOR CONNECTION POINT OF NEW WORK TO EXISTING RTU-3 LENNOX LGH072H 1100 2100 N/A N/A 750 2100 2 (IN) AIRFLOW (HP) RTU-4 LENNOX LGH060H 1100 2000 N/A N/A 750 2000 2 AC-1 RECEIVING MARS STD2108-2U 108 5100 (2) @ 1/2 460/3/60 A-F DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER AC-2 RECEIVING MARS STD272-2U 72 5100 (2) @ 1/2 460/3/60 A-F NOTES: AC-3 ENTRY BERNER MAX2072A 72 3026 (1) @ 1/5 120/1/60 A-D, F-H FOR ASSISTANCE SETTING UP THE BLOWER PROFILE CONTACT LENNOX NATIONAL ACCOUNT TECHNICAL AC-4 ENTRY BERNER MAX2072A 72 3026 (1) @ 1/5 120/1/60 A-D, F-H SECTION CUT DESIGNATION SUPPORT AT 1-800-367-6285 MSAV (MULTI STAGE AIR VOLUME) UNITS HAVE TWO MINIMUM DAMPER POSTIONS THAT MUST BE SET FOR HIGH AND LOW SPEED BLOWER OPERATION. NOTES: LOW SPEED DAMPER POSITION SHOULD BE OPEN MORE THAN HIGH SPEED DAMPER POSITION IN ORDER TO MAINTAIN PROPER BUILDING PRESSURE. A. EQUIPMENT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. B. MOUNT UNIT PER MANUFACTURERS RECOMMENDATIONS TO FACE OF WALL AND SUPPORT VERTICALLY. C. PROVIDE INTEGRAL STARTER AND DISCONNECT SWITCH. D. REFER TO SEQUENCE OF OPERATION FOR UNIT CONTROLS. E. PROVIDE WITH DELAY MICROSWITCH WITH ADJUSTABLE DELAY TIMERS PRE MOUNTED IN THE AIR CURTAIN CONTROL PANEL. F. PROVIDE STANDARD FACTORY FINISH AND COLOR. MARK HOOD MANUFACTURER MODEL LENGTH CFM/FT NOTES G. APPROVED EQUAL IS POWERED AIRE. TYPE H. PROVIDE WITH MAGNETIC DOOR CONTACT FOR CONNECTION WITH INTELLISWITCH FOR "AUTO" OPERATION. H-1 TYPE I GREASEMASTER 6024 GSN-2 11'-0" 110 A-D

NOTES: A. PROVIDE 3" AIR GAP AT BACK OF TYPE I HOOD. AREA GROSS CODE OUTSIDE AIR SYSTEM ACTUAL B. PROVIDE FAN SWITCHES. PURPOSE FLOOR REQUIREMENTS NUMBER OUTSIDE AIR C. PROVIDE LIGHTS AND LIGHT SWITCHES AS REQUIRED. AREA 2009 IMC Table 403.3 (CFM PER UNIT) D. INSTALL HOOD AT 84" AFF. (SQ. FT) CFM PER CFM CFM PER NO. OF CFM RTU-1 350 SQ. FT REQD. PERSON PEOPLE REQD. RTU-2 0 VESTAVIA HILLS, AL 35216 AL HILLS, VESTAVIA CITY CITY SUBMITTAL 03-27-2015 - SPROUTS FARMERS MARKET FARMERS SPROUTS MECHANICAL SCHEDULES & NOTES & MECHANICAL SCHEDULES 100 Main Sales Area 16,804 0.06 1,009 7.5 135 1,013 RTU-3 350 101 SUITE 1031 MONTGOMERY HIGHWAY, 101 Scan 125 0.06 8 5 1 5 RTU-4 130 DATE: 03-27-15 102 Cashier 87 0.06 6 5 1 5 DHU-1 2,025 103 Bookkeeping 87 0.06 6 5 1 5 SCALE: 104 Manager 90 0.06 6 5 1 5 107 Hall 392 0.06 24 - - - DRAWN BY: MFA 108 Breakroom 181 0.06 11 5 10 50 109 Deli Prep 1846 - - 15 9 135 PROJECT 14-139 110 Service Meat 225 - - 15 2 30 NUMBER: 116 Bulk/Produce Prep Area 669 - - 15 5 75 SHEET: 118 Stock Area 1417 0.12 170 - - - 119 Receiving 655 0.12 79 - - - Vestibules 793 0.06 48 - - - Seating 210 0.06 13 7.5 20 150 AC1 TOTAL = 1,380 1,473 TOTAL = 2,855 COMBINED TOTAL= 2,853 REV: