Commercial Kitchen Ventilation Testing Requirements
COMMERCIAL KITCHEN VENTILATION TESTING REQUIREMENTS CALL FIRE MARSHAL/FIRE SUB CODE OFFICIAL AT 908-454-6121 EXT 360 TO SCHEDULE ACCEPTANCE TESTING IMC 506.3.2.5 GREASE DUCT TEST Prior to the use or concealment of any portion of grease duct system, a leakage test shall be performed in the presence of the Fire Inspector. Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on ALL sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. A light test or approved equivalent test method shall be performed to determine that all welded and brazed joints are liquid tight. A light test shall be performed by passing a lamp having a power rating of not less than 100 watts (or 1500 lumens for energy efficient bulb types) through the entire section of duct work to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular to the duct walls. At test shall be performed for the entire duct system, including the hood-to-duct connection. The ductwork shall be permitted to be testing in sections, provided that every joint is tested. IMC 507.16 PERFORMANCE TEST A performance test shall be conducted upon completion and before final approval of installation of a ventilation system serving commercial cooking appliances. The test shall verify the rate of exhaust airflow required by Section 507.13, makeup airflow required by Section 508, and proper operation as specified in this chapter the permit holder shall furnish the necessary test equipment and devices required to perform the tests. -
Commercial Kitchen Ventilation- Efficient Exhaust and Heat Recovery
#331-1 CH-89-9-6 Commercial Kitchen Ventilation Efficient Exhaust and Heat Recovery D.K. Black ASHRAE Life Member ABSTRACT ciency and, if it malfunctions, can shut down the entire This paper outlines those considerations and kitchen and restaurant. requirements that are pertinent to the design and opera The subject of commercial kitchen ventilation covers tion of a properly functioning exhaust system 'for a a number of factors or considerations that combine to form commercial kitchen. It embraces such subjects as air the basis of a system that will perform satisfactorily, be cost quality, energy conservation, air pollution control, sanita effective, and comply with applicable codes. tion, and fire safety. Determination of necessary and These factors include smoke capture, grease extrac appropriate exhaust air volumes for various items of cobk· tion and disposal, fire protec1ion. and the maintenance of ing equipment is discussed. The potential for heat acceptable air quality and temperature in the kitchen recovery Is detailed, together with a description of the space. Modern systems may also include air pollutioh con technology involved. trol and heat recovery equipment. Efficient grease extraction is extremely important. INTRODUCTION Grease that is hOt exhausted will collect in ductwork and The state of the art in commercial kitchen ventilation create a fire hazard. To such areas, the difference between is indeed essentially an art, accepting certain basic funda 90% and 95% efficiency is not 5% but rather 100%. mentals of thermodynamics, environmental control, and air Centrifugal ~rease extraction has proved to be highly movement, but responding largely to experience and effective and is currently employed on most leading logic. -
Model Ipic Series 4G Grease Duct
INSTALLATION AND WALMART MAINTENANCE APPLICATION INSTRUCTIONS 637N MODEL IPIC 7N71 SERIES 4G GREASE DUCT IT IS OF THE UTMOST IMPORTANCE THAT THIS DUCT BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. IMPORTANT: DO NOT INSTALL GREASE DUCT WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY. COMBUSTIBLE MATERIAL: Material made of or surfaced with wood, compressed paper, plant fibers, plastic or other material that will ignite and burn, whether flame proofed or not, or whether plastered or unplastered. Metal-Fab’s series 4G Grease Duct System has been fully tested, listed and classified by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada. Metal-Fab’s Series 4G Grease Duct Systems have been evaluated and accepted by BOCA, SBCCI, and ICBO as an alternative to a two hour fire rated shaft enclosure when installed in accordance with these installation instructions. Grease Duct installed in accordance with these Installation Instructions meet the requirements of NFPA96. These instructions contain complete information on details concerning dimensions, installation, clearance to combustibles, use of noncombustible enclosures, and Firestops. For any additional information, refer to the parts catalog. METAL-FAB INC., • P.O. BOX 1138, WICHITA, KANSAS 67201 • (316) 943-2351 GENERAL INFORMATION LISTINGS: Metal-Fab IPIC Series 4G Grease Duct Systems (6” thru 36” diameter) are classified by Underwriters Laboratories, Inc. (UL File No. R15388) in accordance with SBCCI acceptance criteria for Grease Duct Enclosure Systems (January 1, 1998). The IPIC Series 4G Grease Ducts for use in Grease Duct Assembly No. G-1 is Classified as an alternate to 3 hr. fire resistive rated shaft enclosure system with a minimum zero clearance to combustibles. -
Grain Crop Drying, Handling and Storage
363 Chapter 16 Grain crop drying, handling and storage INTRODUCTION within the crop, inhibiting air movement and adding Although in many parts of Africa certain crops can be to any possible spoilage problems. The crop must produced throughout the year, the major food crops therefore be clean. such as cereal grains and tubers, including potatoes, One of the most critical physiological factors in are normally seasonal crops. Consequently the food successful grain storage is the moisture content of the produced in one harvest period, which may last for only crop. High moisture content leads to storage problems a few weeks, must be stored for gradual consumption because it encourages fungal and insect problems, until the next harvest, and seed must be held for the respiration and germination. However, moisture next season’s crop. content in the growing crop is naturally high and only In addition, in a market that is not controlled, the value starts to decrease as the crop reaches maturity and the of any surplus crop tends to rise during the off-season grains are drying. In their natural state, the seeds would period, provided that it is in a marketable condition. have a period of dormancy and then germinate either Therefore the principal aim of any storage system must when re-wetted by rain or as a result of a naturally be to maintain the crop in prime condition for as long adequate moisture content. as possible. The storage and handling methods should Another major factor influencing spoilage is minimize losses, but must also be appropriate in relation temperature. -
Significant Changes to the March 2017 International Mechanical Code
Significant Changes to the March 2017 International Mechanical Code State of Connecticut Department of Administrative Services Division of Construction Services Office of Education and Data Management Office of Education and Data Management Spring 2017 Career Development Series Significant Changes to the International Mechanical Code Presented by John Tye Office of the State Building Inspector, DAS “2012” International Mechanical Code Update The following presentation contains “significant” code changes which took place in the International Mechanical Code from 2003 through 2012. Office of Education 2 and Data Management Office of Education and Data Management 1 Significant Changes to the March 2017 International Mechanical Code IMC update 2012 Many code changes have taken place in the IMC since 2003. This seminar will only be able to identify a small number of these changes. Confusion still exists between proper code use such as the IRC versus the IMC for fuel gas installations. The IMC does not address gas or gas related equipment. Office of Education 3 and Data Management IMC update (continued) The IRC uses both its Chapter 24(based on the IFGC) and the 2012 NFPA 54 document for gas piping and equipment installations. The Ct. supplement to the IRC includes the NFPA 54 document. Section 101.4.1 (Add) As I stated in the previous slide the IMC references the International Fuel Gas Code (IFGC) (member of the ICC family of codes). The State of Connecticut did not adopt the IFCG and instead references the NFPA 54 document, currently the 2012 edition for gas piping and equipment installations. Office of Education 4 and Data Management Office of Education and Data Management 2 Significant Changes to the March 2017 International Mechanical Code IMC update (continued) Any reference to the IFGC in either the IMC or IRC shall be considered a reference to NFPA 54, NFPA 2, and NFPA 58. -
Kitchen Ventilation Improvement
Kitchen Ventilation Improvement Course No: M01-003 Credit: 1 PDH Steven Liescheidt, P.E., CCS, CCPR Continuing Education and Development, Inc. 22 Stonewall Court Woodcliff Lake, NJ 07677 P: (877) 322-5800 [email protected] Design Guide Improving Commercial Kitchen Ventilation System Performance This design guide provides informa- tion that will help achieve optimum Introduction performance and energy efficiency in An effective commercial kitchen ventilation (CKV) system requires bal- commercial kitchen ventilation sys- ance—air balance that is. And as the designer, installer or operator of the kitchen tems. The information presented is applicable to new construction and, in ventilation system, you may be the first person called upon to perform your own many instances, retrofit construction. “balancing act” when the exhaust hood doesn’t work. Unlike a cooking appliance, The audience for this guideline is which can be isolated for troubleshooting, the exhaust hood is only one component kitchen designers, mechanical engi- of the kitchen ventilation system. To further complicate things, the CKV system is a neers, food service operators, prop- subsystem of the overall building heating, ventilating and air-conditioning (HVAC) erty managers, and maintenance people. This guide is intended to system. Fortunately, there is no “magic” to the relationship between an exhaust hood augment comprehensive design in- and its requirement for replacement or makeup air (MUA). The physics are simple: formation published in the Kitchen air that exits the building (through exhaust hoods and fans) must be replaced with Ventilation Chapter in the ASHRAE outside air that enters the building (intentionally or otherwise). The essence of air Handbook on HVAC Applications. -
Introduction to Ventilation & Indoor Air Quality
INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY PRESENTED BY: Eng. Shehab S. Bekhet INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY How much time - %, do we spend indoors?? 2 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY We Spend 90% of Our Time Indoors! ! 3 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY 4 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY Shehab Bekhet Senior Mechanical Engineer Dar Al Handasah More than 27 years of various experience, gained throughout long career path covers wide and diversified fields and ranges of responsibilities combining design, construction and technical back-up skills. The range of mechanical works cover preliminary & detailed design, preparation of specification and tender documents, follow up, approval of shop drawings and project management and construction supervision of building services including HVAC, plumbing, fire protection, building automation and control systems. Successfully contributed to design and construction of several large projects in more than 12 countries in the Gulf Area, Middle East, and Africa, such as: • Dubai International Airport- UAE • Higher College for Men & Women- UAE • Development of King Abdul Aziz Endowment for the Two Holy Mosques. • Al Hassa & Al Dammam Hospital – Saudi Arabia • Rafik Al Hariri Airport – Lebanon • Sheraton Hotel Rehabilitation – Egypt. A keynote speaker and administered many of training courses and seminars in various topics of HVAC systems. INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY 6 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY Introductory Film Indoor Ar Quality INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY 8 INTRODUCTION TO VENTILATION & INDOOR AIR QUALITY The presentation covers the following main items: Indoor Air Quality, (IAQ): . Definition. Common Pollutants and health effect. -
Duct Fire Protection Products
23 07 00/THE Duct Fire Protection Products BuyLine 8880 Thermal Ceramics, a global manufacturer of high temperature insulation prod- ucts, has provided engineered solutions for heat containment problems for over 75 years, and was the first to develop flexible fire resistive duct enclosures, mar- keted under the brandname of FireMaster®, for commercial kitchen grease and air ventilation ducts. Unlike imitation wraps in today’s market, Thermal Ceramics has the widest range of duct enclosure products that are performance-tested beyond minimum laboratory listings or code requirements. This assures fire con- tainment, from the typical to the most complex duct designs, without theorizing. Thermal Ceramics innovative duct products are high temperature (2000°F) fire rated solutions that do not age, become brittle, or shrink during in-service opera- tions, like lower temperature mineral wool wraps. The duct products in the FireMaster line are resistant to mold growth in test conditions of 75-95% relative humidity (ASTM D6329). With zero flame and smoke ratings on the blanket, and only a 5 flame spread and 10 smoke rating on the foil encapsulation, Thermal Ceramics duct products do not add toxic emissions to fire conditions. With a vast number of field installations worldwide and over 20 years of successful fire con- tainment in real-world fires, the duct products in the FireMaster line have proven their worth. Typical Applications • Commercial Kitchen Grease Ducts • Air Ventilation Ducts • Chemical Exhaust Ducts • Stair Pressurization Ducts • Hazardous Exhaust Ducts • Trash and linen chutes Duct Fire Protection Products 2000°F Rigid Flexible External 2 Hr Internal 2000°F Commercial Kitchen Shaft Alternative Installation ASTM E119 & Grease Duct Fire Grease Duct Method E814 Performance Containment Air Ventilation Duct Systems Installation Experience Complies with • Wynn Hotel, Las Vegas, NV - Grease duct • Baylor University Bio-Science College, Waco, Texas - Chemical exhaust duct • M.D. -
Grease Duct Enclosures Fire and Smoke Dampers in Grease Ducts
506.3.11 CHANGE TYPE: Modification CHANGE SUMMARY: The code specifically prohibits the installation of Grease Duct Enclosures fire and smoke dampers in grease ducts. 2015 CODE: 506.3.11 Grease Duct Enclosures. A commercial kitchen grease duct serving a Type I hood that penetrates a ceiling, wall, floor or any concealed spaces shall be enclosed from the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either a shaft enclosure in accordance with Section 506.3.11.1, a field-ap- plied enclosure assembly in accordance with 506.3.11.2 or a factory-built enclosure assembly in accordance with Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than that of the assembly pen- etrated and not less than 1 hour. Fire dampers and smoke dampers shall not be installed in grease ducts. Duct enclosures shall be as prescribed by Section 506.3.11.1, 506.3.11.2 or 506.3.11.3. 506.3.11.4 Duct enclosure not required. This excerpt is taken from Exception: A duct enclosure shall not be required for a grease duct Significant Changes to the that penetrates only a non-fire-resistance-rated roof/ceiling assembly. International Plumbing/ CHANGE SIGNIFICANCE: It has long been understood that fire and smoke dampers are not compatible with grease ducts, and the duct en- Mechanical/ closure requirements clearly account for the lack of such dampers where Fuel Gas the ducts penetrate walls, floors and ceilings. -
Analysis of Ozone Technology in Commercial Kitchen Ventilation TB16-1003
Analysis of Ozone Technology in Commercial Kitchen Ventilation TB16-1003 February 1, 2016 A recent addition to the commercial kitchen ventilation industry has been the introduction of ozone to the kitchen exhaust process. This new exhaust method utilizes an ozone creation device that feeds ozonated air into the exhaust airstream following the greasy air’s departure from the hood and coinciding with its entrance into the duct. Manufacturers of ozone technology hold that a two-stage filtration method of utilizing traditional hood filters (Stage 1) coupled with ozonated air (Stage 2) outperforms standard mechanical-only filtration for grease and odor reduction. This technical bulletin investigates this claim in order to determine whether or not ozone technology is an effective and reliable means of grease and odor reduction. Background The basis of the ozone exhaust theory rests on the creation of ozone, produced by Corona Discharge (CD) ozone generators in most cases (e.g., one manufacturer uses proprietary Corona Class Cells [CGCs] for this process). As power is supplied to the CGCs, a strong electric field is created over a dielectric and between an air gap. The dielectric allows the charge to be spread over a large area as opposed to remaining at a single point, as in the case of a spark. As oxygen molecules (O2) flow through the gap, they are exposed to the electrical discharge and split into two monatomic oxygen atoms - (O ). These freed oxygen atoms then combine with other oxygen molecules to form ozone molecules (O3) [1]. Fig 1: Corona Discharge Cell Configuration Source: Principles of Ozone Generation, Wayne Smith, Watertec Engineering Pty Ltd It is important to note that the type of feed gas, the power input/frequency, the unit construction and the temperature and humidity level of the air all greatly affect the amount of ozone generated. -
Fall-2017-Journal-Web.Pdf
ISSUE 44 | Fall 2017 IN EACH ISSUE 05 Letter from the IKECA President Randy Rauth, CECS | Hood Cleaning, Inc. 06 IKECA Member News 31 New Certifications 32 New Members FEATURED ARTICLES 07 The Key to Employee Retention Brian Smith, Ph.D. | IA Business Advisors/Omni Containment Systems 11 Integrity Mark Eckhert, CESI 12 Creosote and Restaurant Kitchen Grease Fumes Eric Dyer, CECS | Kescor, Inc. DON’T MISS IN THIS ISSUE 21 Be the Leader Dennis Poulin, CECS | R&G Vent Cleaning Services, Inc. 22 Refrigeration and Freezer Maintenance Richard Fennelly, CESI 24 Grease Extraction Efficiency Explained Randy Conforti CECS, CESI | Precision Kleen, Inc. and Heat Transfer Specialists 26 Final Rule to Improve Tracking of Workplace Injuries and Illnesses OSHA Article 28 Cleaning High-Rise Kitchen Exhaust Verticals AHJ CORNER 29 AHJ Inspector Top 10 List The IKECA Journal is an industry publication for cleaners, fire marshals, insurance ISSUE 44 professionals, facility managers, vendors and other interested parties in the commercial kitchen exhaust cleaning and inspection industry FALL 2017 Serving the Commercial Kitchen Exhaust Industry Worldwide The IKECA Journal is an industry publication for cleaners, fire marshals, insurance professionals, facility managers, vendors and other interested parties in the commercial kitchen ex- haust cleaning and inspection industry. IKECA President Randy Rauth, CECS IKECA Interim Executive Director Elizabeth Franks IKECA Journal Editor Dana Butler IKECA Journal Editorial Review Board Christoper Bisbee Grant Mogford, CECS, CESI Kevin Pearson, CECS Donald Pfleiderer, CECS, CESI Randy Russo, CECS, CESI Brian Smith, PhD Michael Watz Jason Wellman 100 North 20th Street, Suite 400 Philadelphia, PA 19103 Tel: 215.320.3876 Fax: 215.564.2175 Email: [email protected] The IKECA Journal is a publication of the International Kitchen Exhaust Cleaning Association © 2017. -
Kitchen Hood Test Data Form
CITY OF HENDERSON Department of Building & Fire Safety KITCHEN HOOD TEST DATA Date Permit No. Street Address * * * * * * * * * * * * * * General Contractor Phone Sub-Contractor Phone Address License # HOOD LOCATION PLAN SHEET NO. TESTING EQUIPMENT TYPE TYPE OF HOOD: Type I LIST ALL EQUIPMENT UNDER HOOD: ACTUAL HOOD SIZE: ft x ft = sq. ft. (Hood Width) (Hood Length) (Hood Area) REQUIRED QUANTITY OF AIR: (See UMC 2003 for appropriate formula) Ft x ft x = CFM (Hood Width) (Hood Length) (Formula) (Hood Exhaust) ACTUAL QUANTITY OF AIR AS MEASURED: CFM (Actual Volume) ACTUAL TOTAL FILTER AREA: sq. ft. (Filter Area) ACTUAL FILTER AIR FLOW RATE PER SQ. FT. OF FILTER AREA: CFM - sq. ft. = FPM (Actual Volume) (Filter Area) (Each Filter) LISTED FILTER AIRFLOW RATE: = FPM per filter (As Shown on Filter) ACTUAL DUCT SIZE: Rectangular Duct Ft x ft = sq. ft. (Front Width) (Side Length) (Duct Size) Round Duct .79 x ft = sq. ft. (Duct Diameter) (Duct Size) ACTUAL GREASE DUCT AIR VELOCITY: CFM - sq. ft. = FPM (Actual Volume) (Duct Size) (Duct Velocity) REQUIRED DUCT SYSTEM AIR VELOCITY FOR SHOP MADE HOODS: 1500 FPM (minimum) 2500 FPM (maximum) MANUFACTURERS STATED VELOCITY FOR LISTED HOODS: (Minimum) (Maximum) MAKEUP AIR SOURCE AND SIZE: (Size of source in total CFM) THE EXHAUST AND MAKEUP AIR SYSTEMS SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCK SWITCH. 2000 Southern Nevada Uniform Mechanical Code Amendments - 509.11 ( Performance Test) Upon completion and before final approval of the installation of ventilation system serving commercial food heat-processing equipment, a performance test, shall be performed to verify the rate of airflow and proper operation as specified in this chapter.