Commercial Kitchen Ventilation Testing Requirements
COMMERCIAL KITCHEN VENTILATION TESTING REQUIREMENTS CALL FIRE MARSHAL/FIRE SUB CODE OFFICIAL AT 908-454-6121 EXT 360 TO SCHEDULE ACCEPTANCE TESTING IMC 506.3.2.5 GREASE DUCT TEST Prior to the use or concealment of any portion of grease duct system, a leakage test shall be performed in the presence of the Fire Inspector. Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on ALL sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. A light test or approved equivalent test method shall be performed to determine that all welded and brazed joints are liquid tight. A light test shall be performed by passing a lamp having a power rating of not less than 100 watts (or 1500 lumens for energy efficient bulb types) through the entire section of duct work to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular to the duct walls. At test shall be performed for the entire duct system, including the hood-to-duct connection. The ductwork shall be permitted to be testing in sections, provided that every joint is tested. IMC 507.16 PERFORMANCE TEST A performance test shall be conducted upon completion and before final approval of installation of a ventilation system serving commercial cooking appliances. The test shall verify the rate of exhaust airflow required by Section 507.13, makeup airflow required by Section 508, and proper operation as specified in this chapter the permit holder shall furnish the necessary test equipment and devices required to perform the tests. -
Model Ipic Series 4G Grease Duct
INSTALLATION AND WALMART MAINTENANCE APPLICATION INSTRUCTIONS 637N MODEL IPIC 7N71 SERIES 4G GREASE DUCT IT IS OF THE UTMOST IMPORTANCE THAT THIS DUCT BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. IMPORTANT: DO NOT INSTALL GREASE DUCT WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY. COMBUSTIBLE MATERIAL: Material made of or surfaced with wood, compressed paper, plant fibers, plastic or other material that will ignite and burn, whether flame proofed or not, or whether plastered or unplastered. Metal-Fab’s series 4G Grease Duct System has been fully tested, listed and classified by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada. Metal-Fab’s Series 4G Grease Duct Systems have been evaluated and accepted by BOCA, SBCCI, and ICBO as an alternative to a two hour fire rated shaft enclosure when installed in accordance with these installation instructions. Grease Duct installed in accordance with these Installation Instructions meet the requirements of NFPA96. These instructions contain complete information on details concerning dimensions, installation, clearance to combustibles, use of noncombustible enclosures, and Firestops. For any additional information, refer to the parts catalog. METAL-FAB INC., • P.O. BOX 1138, WICHITA, KANSAS 67201 • (316) 943-2351 GENERAL INFORMATION LISTINGS: Metal-Fab IPIC Series 4G Grease Duct Systems (6” thru 36” diameter) are classified by Underwriters Laboratories, Inc. (UL File No. R15388) in accordance with SBCCI acceptance criteria for Grease Duct Enclosure Systems (January 1, 1998). The IPIC Series 4G Grease Ducts for use in Grease Duct Assembly No. G-1 is Classified as an alternate to 3 hr. fire resistive rated shaft enclosure system with a minimum zero clearance to combustibles. -
Significant Changes to the March 2017 International Mechanical Code
Significant Changes to the March 2017 International Mechanical Code State of Connecticut Department of Administrative Services Division of Construction Services Office of Education and Data Management Office of Education and Data Management Spring 2017 Career Development Series Significant Changes to the International Mechanical Code Presented by John Tye Office of the State Building Inspector, DAS “2012” International Mechanical Code Update The following presentation contains “significant” code changes which took place in the International Mechanical Code from 2003 through 2012. Office of Education 2 and Data Management Office of Education and Data Management 1 Significant Changes to the March 2017 International Mechanical Code IMC update 2012 Many code changes have taken place in the IMC since 2003. This seminar will only be able to identify a small number of these changes. Confusion still exists between proper code use such as the IRC versus the IMC for fuel gas installations. The IMC does not address gas or gas related equipment. Office of Education 3 and Data Management IMC update (continued) The IRC uses both its Chapter 24(based on the IFGC) and the 2012 NFPA 54 document for gas piping and equipment installations. The Ct. supplement to the IRC includes the NFPA 54 document. Section 101.4.1 (Add) As I stated in the previous slide the IMC references the International Fuel Gas Code (IFGC) (member of the ICC family of codes). The State of Connecticut did not adopt the IFCG and instead references the NFPA 54 document, currently the 2012 edition for gas piping and equipment installations. Office of Education 4 and Data Management Office of Education and Data Management 2 Significant Changes to the March 2017 International Mechanical Code IMC update (continued) Any reference to the IFGC in either the IMC or IRC shall be considered a reference to NFPA 54, NFPA 2, and NFPA 58. -
Duct Fire Protection Products
23 07 00/THE Duct Fire Protection Products BuyLine 8880 Thermal Ceramics, a global manufacturer of high temperature insulation prod- ucts, has provided engineered solutions for heat containment problems for over 75 years, and was the first to develop flexible fire resistive duct enclosures, mar- keted under the brandname of FireMaster®, for commercial kitchen grease and air ventilation ducts. Unlike imitation wraps in today’s market, Thermal Ceramics has the widest range of duct enclosure products that are performance-tested beyond minimum laboratory listings or code requirements. This assures fire con- tainment, from the typical to the most complex duct designs, without theorizing. Thermal Ceramics innovative duct products are high temperature (2000°F) fire rated solutions that do not age, become brittle, or shrink during in-service opera- tions, like lower temperature mineral wool wraps. The duct products in the FireMaster line are resistant to mold growth in test conditions of 75-95% relative humidity (ASTM D6329). With zero flame and smoke ratings on the blanket, and only a 5 flame spread and 10 smoke rating on the foil encapsulation, Thermal Ceramics duct products do not add toxic emissions to fire conditions. With a vast number of field installations worldwide and over 20 years of successful fire con- tainment in real-world fires, the duct products in the FireMaster line have proven their worth. Typical Applications • Commercial Kitchen Grease Ducts • Air Ventilation Ducts • Chemical Exhaust Ducts • Stair Pressurization Ducts • Hazardous Exhaust Ducts • Trash and linen chutes Duct Fire Protection Products 2000°F Rigid Flexible External 2 Hr Internal 2000°F Commercial Kitchen Shaft Alternative Installation ASTM E119 & Grease Duct Fire Grease Duct Method E814 Performance Containment Air Ventilation Duct Systems Installation Experience Complies with • Wynn Hotel, Las Vegas, NV - Grease duct • Baylor University Bio-Science College, Waco, Texas - Chemical exhaust duct • M.D. -
Grease Duct Enclosures Fire and Smoke Dampers in Grease Ducts
506.3.11 CHANGE TYPE: Modification CHANGE SUMMARY: The code specifically prohibits the installation of Grease Duct Enclosures fire and smoke dampers in grease ducts. 2015 CODE: 506.3.11 Grease Duct Enclosures. A commercial kitchen grease duct serving a Type I hood that penetrates a ceiling, wall, floor or any concealed spaces shall be enclosed from the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either a shaft enclosure in accordance with Section 506.3.11.1, a field-ap- plied enclosure assembly in accordance with 506.3.11.2 or a factory-built enclosure assembly in accordance with Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than that of the assembly pen- etrated and not less than 1 hour. Fire dampers and smoke dampers shall not be installed in grease ducts. Duct enclosures shall be as prescribed by Section 506.3.11.1, 506.3.11.2 or 506.3.11.3. 506.3.11.4 Duct enclosure not required. This excerpt is taken from Exception: A duct enclosure shall not be required for a grease duct Significant Changes to the that penetrates only a non-fire-resistance-rated roof/ceiling assembly. International Plumbing/ CHANGE SIGNIFICANCE: It has long been understood that fire and smoke dampers are not compatible with grease ducts, and the duct en- Mechanical/ closure requirements clearly account for the lack of such dampers where Fuel Gas the ducts penetrate walls, floors and ceilings. -
Kitchen Hood Test Data Form
CITY OF HENDERSON Department of Building & Fire Safety KITCHEN HOOD TEST DATA Date Permit No. Street Address * * * * * * * * * * * * * * General Contractor Phone Sub-Contractor Phone Address License # HOOD LOCATION PLAN SHEET NO. TESTING EQUIPMENT TYPE TYPE OF HOOD: Type I LIST ALL EQUIPMENT UNDER HOOD: ACTUAL HOOD SIZE: ft x ft = sq. ft. (Hood Width) (Hood Length) (Hood Area) REQUIRED QUANTITY OF AIR: (See UMC 2003 for appropriate formula) Ft x ft x = CFM (Hood Width) (Hood Length) (Formula) (Hood Exhaust) ACTUAL QUANTITY OF AIR AS MEASURED: CFM (Actual Volume) ACTUAL TOTAL FILTER AREA: sq. ft. (Filter Area) ACTUAL FILTER AIR FLOW RATE PER SQ. FT. OF FILTER AREA: CFM - sq. ft. = FPM (Actual Volume) (Filter Area) (Each Filter) LISTED FILTER AIRFLOW RATE: = FPM per filter (As Shown on Filter) ACTUAL DUCT SIZE: Rectangular Duct Ft x ft = sq. ft. (Front Width) (Side Length) (Duct Size) Round Duct .79 x ft = sq. ft. (Duct Diameter) (Duct Size) ACTUAL GREASE DUCT AIR VELOCITY: CFM - sq. ft. = FPM (Actual Volume) (Duct Size) (Duct Velocity) REQUIRED DUCT SYSTEM AIR VELOCITY FOR SHOP MADE HOODS: 1500 FPM (minimum) 2500 FPM (maximum) MANUFACTURERS STATED VELOCITY FOR LISTED HOODS: (Minimum) (Maximum) MAKEUP AIR SOURCE AND SIZE: (Size of source in total CFM) THE EXHAUST AND MAKEUP AIR SYSTEMS SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCK SWITCH. 2000 Southern Nevada Uniform Mechanical Code Amendments - 509.11 ( Performance Test) Upon completion and before final approval of the installation of ventilation system serving commercial food heat-processing equipment, a performance test, shall be performed to verify the rate of airflow and proper operation as specified in this chapter. -
Instructions for Use
EN 06/2019 EN FD SOLID FIRE Instructions for use www.attack.sk CONTENTS CONTENTS ...................................................................................................................................................................... 2 INTRODUCTION ............................................................................................................................................................. 3 IMPORTANT WARNINGS ............................................................................................................................................. 3 1 USE AND PREFERENCES OF THE BOILER ..................................................................................................... 4 2 TECHNICAL PARAMETERS OF ATTACK FD SOLID FIRE ........................................................................... 5 3 DIMENSIONS OF BOILERS ATTACK FD SOLID FIRE ................................................................................... 6 4 HEAD LOSSES ....................................................................................................................................................... 6 5 DESCRIPTION ........................................................................................................................................................ 7 5.1 HOW TO CHOOSE THE RIGHT SIZE OF A BOILER .............................................................................. 7 6 LOCATION AND INSTALLATION OF THE BOILER ATTACK FD SOLID FIRE ........................................ 8 6.1 BOILER -
Factory-Built Grease Duct Systems
FACTORY-BUILT GREASE DUCT SYSTEMS For Kitchen Ventilation Systems DESCRIPTION METAL-FAB “G” SERIES Models 3G / 4G Models PIC / 1G / 2G Models PSW ALTERNATE TO FIRE REDUCED CLEARANCE SINGLE WALL RESISTIVE SHAFT ENCLOSURE TO COMBUSTIBLES STAINLESS STEEL Factory - Built Factory - Built Factory - Built INSTALLED SPACE REQUIREMENTS 20" X 20" 20"/22" X 20"/22" 50" X 50" 12" X 12" SQUARE DUCTS - 144 SQ. IN. 14" ROUND DUCT - 154 SQ. IN. CONSTRUCTION Outer Casing (Integral Shaft Encl osure) Outer Casing -Aluminized Carbon Aluminized Carbon or Stainless Steel or Stainless Steel Insulation: 3" or 4" Ceramic Fiber Insulation: Air, 1" or 2" Ceramic Fiber Grease Duct - 20 Gauge Stainless Steel Grease Duct - 20 Gauge Stainless Steel Grease Duct - 20 Gauge Stainless Steel CLEARANCES Zero Clearance to Combustibles See Chart for Reduced Clearances 18 Inches to Combustibles on Page 8 3 Inches to Limited Combustibles CURRENT CODE YES YES YES ACCEPTANCE 2021 IMC 2021 IMC 2021 IMC 2021 UMC 2021 UMC 2021 UMC 2021 NFPA 96 2021 NFPA 96 2021 NFPA 96 New York City: MEA-86-07-E New York City: MEA-245-97-M Los Angeles: RR-8441 Wisconsin: 990074-H APPLICABLE UL1978 - Standard for Grease Ducts UL1978 - Standard for Grease Ducts UL1978 - Standard for Grease Ducts UL2221 - Tests of Fire Resistive LISTINGS Duct Enclosures UL2221 - Condition B, 2G Product NFPA 96 - Requires duct and fire Only, for 6"-18" Diameters wrap to be listed together as an UL103HT 6 "-14" Diameters UL103HT - 2G Product Only, assembly for the intended application. ASTM E 814 - Standard Test Method Must be installed per the for Through Penetration for 6"-14" Diameters Firestops manufacturer’s listing and their installation instructions. -
A31 SI: Kitchen Ventilation
Related Commercial Resources CHAPTER 31 KITCHEN VENTILATION Cooking Effluent ...................................................................... 31.1 System Integration and Balancing ......................................... 31.18 Exhaust Hoods ......................................................................... 31.2 Energy Considerations........................................................... 31.21 Exhaust Systems....................................................................... 31.9 Fire Protection ....................................................................... 31.22 Replacement (Makeup) Air Operation and Maintenance .................................................. 31.25 Systems ............................................................................... 31.13 Residential Kitchen Ventilation.............................................. 31.27 ITCHEN ventilation is a complex application of HVAC sys- ventilation. However, heat radiated to the space from the appliance K tems. System design includes aspects of air conditioning, fire is largely unaffected by ventilation and must be addressed by the safety, ventilation, building pressurization, refrigeration, air distri- space air-conditioning system. Chapter 30 of the 2005 ASHRAE bution, and food service equipment. Kitchens are in many buildings, Handbook—Fundamentals lists typical space heat gain values for including restaurants, hotels, hospitals, retail malls, single- and many commercial kitchen appliances. multifamily dwellings, and correctional facilities. -
Lab Planning Guide R1a 1Condensed-FULL.Pdf
HEMCO has been a leading manufacturer of basic laboratory equipment serving the research and development and life science and technology industries since 1958. HEMCO works with architects, engineers, laboratory planners, contractors, and customers to complete laboratory projects on time and on budget. Located in Independence, Missouri, the heart of America and the crossroads of North America. HEMCO is situated in a major center for transportation, communication, distribution, and manufacturing industries worldwide. HEMCO offers a complete line of furniture, countertops, and fume hoods to equip your laboratory. Our professional staff will work with you to design a layout that is functional, ergonomic, flexible, and, more importantly, meets your process and safety requirements. We specialize in laboratory projects that are personally engineered to meet your time and budget schedules. Our services can include a complete turnkey installation to ensure the one source quality you expect and deserve. HEMCO would welcome the opprotunity to work with you from your concept planning to a completed, operational laboratory. HEMCO’s modern manufacturing and distribution facilities combined with our many years of experience uniquely qualifies us to provide laboratory hoods, laboratory furniture, laboratory enclosures, clean labs, and clean rooms. Our extensive engineering, design, and manufacturing expertise can transform your laboratory concepts into reality. To Order Or Request At Your Service Quote TERMS Payment to HEMCO Corporation for CALL (816) 796-2900 purchase and shipping charges can be made by Monday-Friday 8 AM - 5 PM Master Card, Visa, American Express, company Central Standard Time check, certified check, money order, letter of credit, or wire transfer. For companies with CLICK [email protected] established credit with HEMCO our terms are 24-7 Net 30 days. -
Sime FB Series (Solida) Manual
INDEX 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRUDUCTION . 16 1.2 SUPPLY 1.3 DIMENSIONS 1.4 TECHNICAL FEATURES SOLIDA - ENGLISH SOLIDA 1.5 HEAD LOSSES 2 INSTALLATION 2.1 BOILER ROOM . 17 2.2 CONNECTION TO THE FLUE 2.3 CONNECTION OF THE PLANT 2.4 BRAZIER GRID ASSEMBLY (optional) 2.5 ASSEMBLY OF THE ACCESSORIES . 18 2.6 CASING ASSEMBLY 2.7 DRAUGHT REGULATOR 2.8 HYDRAULIC CONNECTION DIAGRAMS . 19 3 USE AND MAINTENANCE 3.1 PRELIMINARY IGNITION CHECKS . 20 3.2 CLEANING 3.3 MAINTENANCE 1 DESCRIPTION OF THE APPLIANCE IT 1.1 INTRODUCTION 1.2 SUPPLY for the ports, a screw with bakelite knob for the manual adjustment of the blast PT The cast iron “SOLIDA” boilers are a valid The boilers are supplied in three separate gate damper, a contact spring for the solution for the present energetic pro- parcels: bulb of the thermometer and the M6 blems, since they can run with solid fuels: – Boiler body assembled and equipped lever to be fixed at the blast gate dam- GB wood and carbon. with loading port, ash boxes port, smoke per. “Test certificate” to be kept with the chamber with blast gate damper, ash documents of the boiler. “SOLIDA” boilers conform to Directive PED collection basin and thermostatic drau- – Cardboard box for casing with thermo- SL 97/23/CEE. ght regulator. Bag containing: 2 handles meter and documents bag. 1.3 DIMENSIONS DK RO M C.H. flow RUS 2” (UNI-ISO 7/1) R C.H. return 2” (UNI-ISO 7/1) S Boiler drain FR 1/2” (UNI-ISO 7/1) BE Fig. -
OBROUND GREASE DUCT ™ Slimvent OBROUND GREASE DUCT
TM OBROUND GREASE DUCT ™ SlimVent OBROUND GREASE DUCT SlimVent™ is a UL Classified zero-clearance grease duct system with the space saving profile of a field fabricated rectangular product. SlimVent™ is a flat oval shaped grease duct that MATERIAL THICKNESS provides all the maximum fire protection of a factory • Liners: 20 gauge (.035") fabricated round product, UL 2221 Classification, with the space savings previously only available with field- • Shells: 22 gauge (.034") aluminized or 430 SS fabricated non UL Classified rectangular systems. 20 gauge (.035") 304 or 316 SS LISTING SUPPORT LIMITS The Schebler SlimVent™ grease duct system is Underwriters Support plates and wall supports are utilized to support the weight of Laboratories Inc. UL 1978 Listed and UL 2221 Classified under the grease duct. In horizontal runs, supports should be placed adjacent file number R25748 and control number 41RE as azero clearance to fittings that are not otherwise supported. to combustibles, 2-hour fire rated grease duct. It also has the Underwriters Laboratories mark for Canada (cUL). TESTS PERFORMED The SlimVent™ system has endured rigorous tests by Underwriters SYSTEM CONCEPT Laboratories. Just a few of the test performed are: • Prefabricated, modular, double wall system • Structural Tests The support plates and wall supports • No field welding is required have been physically tested to carry a load 4 times that • 4-inch insulation (11 lbs per sq in.) zero clearance allowed by our listing. to combustibles • Wind Load Tests Loads equivalent to 110 mph wind • Easy-to-handle section lengths RapidLock have been applied to the chimney with acceptable results. connected with the RapidLock™ Connection System • Fire Barrier The system and fire stop have been Connection System subjected to temperatures up to 2000º to ensure • Pressure-tight drawbands and high-temperature sealant structural integrity of the system and effectiveness of a fire stop in preventing fire passage to multiple COMPLETE LINE OF FITTINGS AND SIZES floors of a building’s structure.