Electron Radiotherapy Past, Present & Future
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Potential Efficacy of the Monte Carlo Dose Calculations of 6MV Flattening
Potential Efficacy of the Monte Carlo Dose Calculations of 6MV Flattening Filter-Free Photon Beam of M6™ Cyberknife® System by Taindra Neupane A Thesis Submitted to the Faculty of The Charles E. Schmidt College of Science in Partial Fulfillment of the Requirements for the Degree of Professional Science Master Florida Atlantic University Boca Raton, FL December 2018 Copyright 2018 by Taindra Neupane ii Acknowledgements First, I would like to express my gratitude to my Advisor, Dr. Charles Shang for providing me the opportuinity to do this research at Lynn Cancer Institute, Boca Raton Regional Hospital at Boca Raton and his guidance, enthusiasm and motivation which helped me to accomplish this reasearch. I would also like to thank my committee members, Dr. Theodora Leventouri, and Dr. Silvia Pella for their constructive guidance and support. I am particularly grateful to Dr. Theodora Leventouri, Professor of Physics, for her relentless encouragement, direction and assistance for my academics at the department. I am also thankful to all the faculty members and fellow graduate students in the department of physics who contributed to my learning process directly and indirectly. Finally, I would like to thank Dr. Francescon and Dr. Reynaert for providing the sample input files, the EGSnrc Google Plus Forum for answering my questions during the MC simulations, Musfiqur Rahaman for his help in technical problems, and my family members for their continuous support. iv Abstract Author: Taindra Neupane Title: Potential Efficacy of the Monte Carlo Dose Calculations of 6MV Flattening Filter-Free Photon Beam of M6™ Cyberknife® System Institution: Florida Atlantic University Thesis Co-Advisors: Dr. -
Automation of the Monte Carlo Simulation of Medical Linear
doctoral dissertation AUTOMATIONOFTHEMONTECARLOSIMULATIONOF MEDICALLINEARACCELERATORS miguel lázaro rodríguez castillo Institut de Tecniques` Energètiques Universitat Politècnica de Catalunya Barcelona - November 20th, 2015 Co-supervisors: Priv.-Doz. Dr. Lorenzo Brualla Klinik- und Poliklinik für Strahlentherapie Universitätsklinikum Essen Universität Duisburg-Essen Dr. Josep Sempau Institut de Tecniques` Energètiques Universitat Politècnica de Catalunya Para mis padres, mi esposa y mis hijos The enjoyment of one’s tools is an essential ingredient of successful work — Donald E. Knuth PUBLICATIONS Publications in scientific journals related to this thesis: • M. Rodriguez, J. Sempau, A. Fogliata, L. Cozzi, W. Sauerwein, and L. Brualla. A geometrical model for the Monte Carlo simu- lation of the TrueBeam linac. Phys. Med. Biol., 60:N219–N229, 2015. • M. Rodriguez, J. Sempau, and L. Brualla. Study of the electron transport parameters used in penelope for the Monte Carlo simulation of linac targets. Med. Phys., 42:2877–2881, 2015. • M. F. Belosi, M. Rodriguez, A. Fogliata, L. Cozzi, J. Sempau, A. Clivio, G. Nicolini, E. Vanetti, H. Krauss, C. Khamphan, P. Fe- noglietto, J. Puxeu, D. Fedele, P. Mancosu, and L. Brualla. Monte Carlo simulation of TrueBeam flattening-filter-free beams using Varian phase-space files: Comparison with experimental data. Med. Phys., 41:051707, 2014. • M. Rodriguez, J. Sempau, and L. Brualla. PRIMO: A graphi- cal environment for the Monte Carlo simulation of Varian and Elekta linacs. Strahlenther. Onkol., 189:881–886, 2013. • M. Rodriguez, J. Sempau, and L. Brualla. A combined approach of variance-reduction techniques for the efficient Monte Carlo simulation of linacs. Phys. Med. Biol., 57:3013–3024, 2012. Additional publication in a scientific journal related to this thesis: • M. -
Dose Calculation Algorithms for External Radiation Therapy: an Overview for Practitioners
applied sciences Review Dose Calculation Algorithms for External Radiation Therapy: An Overview for Practitioners Fortuna De Martino 1, Stefania Clemente 2, Christian Graeff 3, Giuseppe Palma 4,*,† and Laura Cella 4,*,† 1 Post Graduate School in Medical Physics, University of Naples Federico II, 80131 Naples, Italy; [email protected] 2 Unit of Medical Physics and Radioprotection, A.O.U Policlinico Federico II, 80131 Naples, Italy; [email protected] 3 Biophysics Department, GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt, Germany; [email protected] 4 Institute of Biostructure and Bioimaging, National Research Council (CNR), 80145 Naples, Italy * Correspondence: [email protected] (G.P.); [email protected] (L.C.) † These authors share senior authorship. Featured Application: Radiation therapy treatment planning. Abstract: Radiation therapy (RT) is a constantly evolving therapeutic technique; improvements are continuously being introduced for both methodological and practical aspects. Among the features that have undergone a huge evolution in recent decades, dose calculation algorithms are still rapidly changing. This process is propelled by the awareness that the agreement between the delivered and calculated doses is of paramount relevance in RT, since it could largely affect clinical outcomes. The Citation: De Martino, F.; Clemente, aim of this work is to provide an overall picture of the main dose calculation algorithms currently S.; Graeff, C.; Palma, G.; Cella, L. used in RT, summarizing their underlying physical models and mathematical bases, and highlighting Dose Calculation Algorithms for their strengths and weaknesses, referring to the most recent studies on algorithm comparisons. External Radiation Therapy: An This handy guide is meant to provide a clear and concise overview of the topic, which will prove Overview for Practitioners. -
Proton Beam Radiotherapy
DESIGN AND SIMULATION OF A PASSIVE-SCATTERING NOZZLE IN PROTON BEAM RADIOTHERAPY A Thesis by FADA GUAN Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE December 2009 Major Subject: Health Physics DESIGN AND SIMULATION OF A PASSIVE-SCATTERING NOZZLE IN PROTON BEAM RADIOTHERAPY A Thesis by FADA GUAN Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Approved by: Chair of Committee, John W. Poston, Sr. Committee Members, Leslie A. Braby Michael A. Walker Head of Department, Raymond J. Juzaitis December 2009 Major Subject: Health Physics iii ABSTRACT Design and Simulation of a Passive-Scattering Nozzle in Proton Beam Radiotherapy. (December 2009) Fada Guan, B.E., Tsinghua University, China Chair of Advisory Committee: Dr. John W. Poston, Sr. Proton beam radiotherapy is an emerging treatment tool for cancer. Its basic principle is to use a high-energy proton beam to deposit energy in a tumor to kill the cancer cells while sparing the surrounding healthy tissues. The therapeutic proton beam can be either a broad beam or a narrow beam. In this research, we mainly focused on the design and simulation of the broad beam produced by a passive double-scattering system in a treatment nozzle. The NEU codes package is a specialized design tool for a passive double- scattering system in proton beam radiotherapy. MCNPX is a general-purpose Monte Carlo radiation transport code. In this research, we used the NEU codes package to design a passive double-scattering system, and we used MCNPX to simulate the transport of protons in the nozzle and a water phantom. -
STI/PUB/1153 Vol. 2
STANDARDS AND CODES OF PRACTICE IN MEDICAL RADIATION DOSIMETRY VOLUME 2 ALL BLANK PAGES HAVE BEEN RETAINED INTENTIONALLY IN THIS WEB VERSION. BLANK PROCEEDINGS SERIES STANDARDS AND CODES OF PRACTICE IN MEDICAL RADIATION DOSIMETRY PROCEEDINGS OF AN INTERNATIONAL SYMPOSIUM HELD IN VIENNA, AUSTRIA, 25–28 NOVEMBER 2002, ORGANIZED BY THE INTERNATIONAL ATOMIC ENERGY AGENCY, CO-SPONSORED BY THE EUROPEAN COMMISSION (DIRECTORATE-GENERAL ENVIRONMENT), THE EUROPEAN SOCIETY FOR THERAPEUTIC RADIOLOGY AND ONCOLOGY, THE INTERNATIONAL ORGANIZATION FOR MEDICAL PHYSICS AND THE PAN AMERICAN HEALTH ORGANIZATION, AND IN CO-OPERATION WITH THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, THE EUROPEAN FEDERATION OF ORGANISATIONS FOR MEDICAL PHYSICS, THE INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS, THE INTERNATIONAL SOCIETY FOR RADIATION ONCOLOGY AND THE WORLD HEALTH ORGANIZATION In two volumes VOLUME 2 INTERNATIONAL ATOMIC ENERGY AGENCY VIENNA, 2003 Permission to reproduce or translate the information contained in this publication may be obtained by writing to the International Atomic Energy Agency,Wagramer Strasse 5, P.O. Box 100,A-1400 Vienna,Austria. © IAEA, 2003 IAEA Library Cataloguing in Publication Data International Symposium on Standards and Codes of Practice in Medical Radiation Dosimetry (2002 : Vienna, Austria) Standards and codes of practice in medical radiation dosimetry : proceedings of an international symposium held in Vienna, Austria, 25–28 November 2002 / organized by the International Atomic Energy Agency ; co-sponsored by the European Commission, Directorate- General Environment...[et al.]. In 2 vols. — Vienna: The Agency, 2003. 2 v. ; 24 cm. — (Proceedings series, ISSN 0074–1884) Contents : v. 2. STI/PUB/1153 ISBN 92–0–111403–6 Includes bibliographical references. 1. -
Intercomparison Procedures in the Dosmetry of And
INTERCOMPARISON PROCEDURES DOSMETRE TH N I F YO HIGH-ENERGY X-RAY AND ELECTRON BEAMS REPOR ADVISORN A F TO Y GROUP MEETING ORGANIZED BY THE INTERNATIONAL ATOMIC ENERGY AGENCY AND HELD IN VIENNA 2-6 APRIL 1979 A TECHNICAL DOCUMENT ISSUEE TH Y DB INTERNATIONAL ATOMIC ENERGY AGENCY, VIENNA, 1981 The IAEA does not maintain stocks of reports in this series. However, microfiche copies of these reports can be obtained from IN IS Microfiche Clearinghouse International Atomic Energy Agency Wagramerstrasse5 0 10 P.Ox Bo . A-1400 Vienna, Austria on prepayment of Austrian Schillings 25.50 or against one IAEA microfiche service coupon to the value of US S2.00. CONTENTS REPORT AND RECOMMENDATIONS OF THE ADVISORY GROUP Repor recommendationd an t Advisore th f so y Group..................7 . APPENDI . I XIAEA/WH O postal dose intercomparison (TLD) for high energy X-ray therapy. Instruction sheet................7 1 . APPENDI . XII IAEA/WH O postal dose intercomparison (TLD) for high energy X-ray therapy. Data sheet........................ 21 EXPERIENCE WITH AND THE NEED FOR DOSE INTERCOMPARISONS The IAEA/WHO thermoluminescent dosimetry intercomparison used for the improvemen clinicaf o t l dosimetry ............................7 2 . N.T. Racoveanu A surve f clinicallo y y applied dosimetry (Summary e reporth n o t IAEA/WHO postal dose intercomparison of cobalt-60 telecurie units with TLD) ........................................................3 3 . Seelenta. W g Dose intercomparison programm Regionae th f o e l Reference Centre of Argentina ...................................................... 45 R. Gonzalez, M.S. de Fernandez Gianotti Experience in intercomparison at an SSDL for orthovoltage and high energy beams ................................................. 51 G. -
Radiation Dose in Radiotherapy from Prescription to Delivery
IAEA-TECDOC-896 XA9642841 Radiation dose in radiotherapy from prescription to delivery INTERNATIONAL ATOMIC ENERGY AGENCY The originating Section of this publication in the IAEA was: Dosimetry Section International Atomic Energy Agency Wagramerstrasse 5 P.O. Box 100 A-1400 Vienna, Austria RADIATION DOSE IN RADIOTHERAPY FROM PRESCRIPTION TO DELIVERY IAEA, VIENNA, 1996 IAEA-TECDOC-896 ISSN 1011-4289 © IAEA, 1996 Printed by the IAEA in Austria August 1996 The IAEA does not normally maintain stocks of reports in this series. However, microfiche copies of these reports can be obtained from INIS Clearinghouse International Atomic Energy Agency Wagramerstrasse 5 P.O. Box 100 A-1400 Vienna, Austria Orders should be accompanied by prepayment of Austrian Schillings 100, in the form of a cheque or in the form of IAEA microfiche service coupons which may be ordered separately from the INIS Clearinghouse. FOREWORD Cancer incidence is increasing in developed as well as in developing countries. However, since in some advanced countries the cure rate is increasing faster than the cancer incidence rate, the cancer mortality rate is no longer increasing in such countries. The increased cure rate can be attributed to early diagnosis and improved therapy. On the other hand, until recently, in some parts of the world - particularly in developing countries - cancer control and therapy programmes have had relatively low priority. The reason is the great need to control communicable diseases. Today a rapidly increasing number of these diseases are under control. Thus, cancer may be expected to become a prominent problem and this will result in public pressure for higher priorities on cancer care. -
Chapter 5. Treatment Machines for External Beam Radiotherapy
Review of Radiation Oncology Physics: A Handbook for Teachers and Students CHAPTER 5. TREATMENT MACHINES FOR EXTERNAL BEAM RADIOTHERAPY ERVIN B. PODGORSAK Department of Medical Physics McGill University Health Centre Montréal, Québec, Canada 5.1. INTRODUCTION Since the inception of radiotherapy soon after the discovery of x-rays by Roentgen in 1895, the technology of x-ray production has first been aimed toward ever higher photon and electron beam energies and intensities, and more recently toward computerization and intensity-modulated beam delivery. During the first 50 years of radiotherapy, the techno- logical progress has been relatively slow and mainly based on x-ray tubes, Van de Graaff generators and betatrons. The invention of the cobalt-60 teletherapy unit by H.E. Johns in Canada in the early 1950s provided a tremendous boost in the quest for higher photon energies, and placed the cobalt unit into the forefront of radiotherapy for a number of years. The concurrently developed medical linear accelerators (linacs), however, soon eclipsed the cobalt unit, moved through five increasingly sophisticated generations, and became the most widely used radiation source in modern radiotherapy. With its compact and efficient design, the linac offers excellent versatility for use in radiotherapy through isocentric mounting and provides either electron or megavoltage x-ray therapy with a wide range of energies. In addition to linacs, electron and x-ray radiotherapy is also carried out with other types of accelerators, such as betatrons and microtrons. More exotic particles, such as protons, neutrons, heavy ions, and negative π mesons, all produced by special accelerators, are also sometimes used for radiotherapy; however, most of the contemporary radiotherapy is carried out with linacs or teletherapy cobalt units. -
Book of Extended Synopses
International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS 2019) 18–21 June 2019 Vienna, Austria Book of Extended Synopses Organized by the CN-273 TABLE OF CONTENTS ORAL PRESENTATIONS Small Field Dosimetry Implementation of the International Code of Practice on Dosimetry of Small Static Fields used in External Beam Radiotherapy (TRS-483) ........................................................... 11 Detector Choice for Depth Dose Curves Including the Build-Up Region of Small MV Photon Fields .................................................................................................................. 15 Output Correction Factors for Eight Ionization Chambers in Small Static Photon Fields ........................................................................................................................................ 17 Reference Dosimetry of a New Biology-Guided Radiotherapy (BgRT) System Following the IAEA TRS-483 CoP ................................................................................................. 20 Uncertainty Contributors in the Dosimetry of Small Static Fields................................. 23 Small Field Photon Beams Audit Pilot Study: Preliminary Results .............................. 25 On the Implementation of the Plan Class-Specific Reference Field Concept Using Multidimensional Clustering of Plan Features ............................................................... 27 Computational Dosimetry Determination of Wair in High-Energy Clinical Electron -
Radiation Therapy Coding
Ed 21:01 Radiation March 2021 Missouri Cancer Registry and Research Center Therapy 2021 Show-Me-Tips Coding...Abstracting...Education… Radiation Therapy Coding Radiation Delivery Systems/Approaches and Coding LINEAR ACCELERATOR - Linac If the radiation treatment summary refers to beam energies, such as: • 6X or 6MV, 10X or 10MV • 12X or 12MV, 15X or 15MV Then the treatment modality will always be 02, external beam, photons (a Linac was used to deliver the EBRT treatment) If radiation treatment summary refers to treatment delivery as: • E, eboost, MeV or “en face” Code the treatment modality 04, external beam, electrons (a Linac can also deliver electron therapy) IORT Delivery Technology & Coding IORT FOR BREAST CANCER, Volume: 41 - Partial Breast. Lymph Nodes are not Targeted! Equipment RT Delivery Modality Planning Comments Method Technique Zeiss Intrabeam 50 kVp Linac 02-Photons 02: Low energy x-ray/ Isotope-free. No photon therapy radioactive source used XOFT Axxent 50 kVp Linac 02-Photons 02: Low energy x-ray/ Isotope-free. No photon therapy radioactive source used LIAC 10/12 by Electron 04-Electrons In most cases, Max energy: 10 MeV, Sordina IORT accelerator 04-3D conformal 12 MeV NOVAC by Electron 04-Electrons In most cases, Check with Rad Onc for Sordina IORT accelerator 04-3D conformal planning technique Mobetron Electron 04-Electrons In most cases, Energies: 6, 9, 12 MeV accelerator 04-3D conformal Strut Assisted Ir-192 Sources 09-Brachy, 88 - NA Accelerated partial breast Volume (HDR) Intracavitary HDR irradiation (PBI) Implant -
An Overview of Auger-Electron Radionuclide Therapy
Current Drug Discovery Technologies, 2010, 7, 000-000 1 Targeting the Nucleus: An Overview of Auger-Electron Radionuclide Therapy Bart Cornelissen* and Katherine A Vallis MRC/CRUK Gray Institute for Radiation Oncology and Biology, University of Oxford, Oxford, United Kingdom Abstract: The review presented here lays out the present state of the art in the field of radionuclide therapies specifically targeted against the nucleus of cancer cells, focussing on the use of Auger-electron-emitters. Nuclear localisation of radi- onuclides increases DNA damage and cell kill, and, in the case of Auger-electron therapy, is deemed necessary for thera- peutic effect. Several strategies will be discussed to direct radionuclides to the nucleoplasm, even to specific protein tar- gets within the nucleus. An overview is given of the applications of Auger-electron-emitting radionuclide therapy target- ing the nucleus. Finally, a few suggestions are made as how radioimmunotherapy with nuclear targets can be improved, and the challenges that might be met, such as how to perform accurate dosimetry measurements, are examined. Keywords: Auger-electron, radionuclide, radioimmunotherapy, nucleus, targeted radiotherapy, molecular radiotherapy, PRRT. 1. INTRODUCTION tumour from within. Because of tumour-specific delivery, radionuclide therapy is also called targeted or molecular ra- The management of solid cancers relies on a combination diotherapy (tRT). Where antibodies or peptides are used to of surgery, systemic chemotherapy and locally delivered guide the radionuclide to epitopes or receptors on malignant radiotherapy. External beam X-ray radiotherapy (XRT) is cells, the terms radioimmunotherapy (RIT) or peptide recep- used in approximately 50% of all cancer patients as it is able tor radionuclide therapy (PRRT) are used, respectively. -
2020 VERSION 4 FINAL Practice Guideline Radiotherapy Skin Care Llv1
SCoTHE SOCIETY & COLLEGER OF RADIOGRAPHERS The Society and College of Radiographers Practice Guideline Document Radiation Dermatitis Guidelines for Radiotherapy Healthcare Professionals Second revised edition April 2020 Review date: 2025 ISBN: 978-1-909802-49-0 Endorsed by © The Society and College of Radiographers 2020. Material may only be reproduced from this publication with clear acknowledgement that it is the original source. If text is being translated into another language or languages, please include a reference/link to the original English-language text. Contents Page Executive summary 1 1. Introduction 4 2. Scope and purpose 8 3. Guideline question 8 4. Guideline development process 8 5. Guideline methodology 9 6. Radiotherapy skin care 26 7. Guideline recommendations 28 8. Implementation strategies 32 9. Recommendations for future research 33 10. Date of publication, review and updating 34 11. References 35 12. List of appendices (separate documents) Appendix 1 Group members Appendix 2 Stakeholder consultation combined and outcomes Appendix 3 External stakeholder comment form Appendix 4 2014 Systematic review 2014 Appendix 5 2014 On-going trails table (1) Appendix 6 2014 On-going trials table (2) Appendix 7 2019 Summary of evidence table Appendix 8 2019 Review summary of evidence table Appendix 9 Other interventions Appendix 10 Staff infosheet skin care Appendix 11 Staff infosheet skin care A5 leaflet Appendix 11 Staff infosheet skin care A5 leaflet – PRINT READY Appendix 12 Patient information sheet Appendix 13 Patient infosheet skin care A5 leaflet Appendix 13 Patient infosheet skin care A5 leaflet – PRINT READY Appendix 14 Skin care presentation Oncology Nursing Society (UKONS) colleagues have been involved in the writing of this document and UKONS recognises it as expert guidelines.