Safety Data Sheet According to 1907/2006/EC, Article 31 Printing Date 17.04.2015 Version Number 2 Revision: 17.04.2015

Total Page:16

File Type:pdf, Size:1020Kb

Safety Data Sheet According to 1907/2006/EC, Article 31 Printing Date 17.04.2015 Version Number 2 Revision: 17.04.2015 Page 1/10 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 17.04.2015 Version number 2 Revision: 17.04.2015 * SECTION 1: Identification of the substance/mixture and of the company/undertaking · 1.1 Product identifier · Trade name: Arcuplat Schnellversilberung m. 30g Ag/l Arcuplat silver bath with 30 g Ag/l · 1.2 Relevant identified uses of the substance or mixture and uses advised against No further relevant information available. · Application of the substance / the mixture Galvanic bath · 1.3 Details of the supplier of the safety data sheet · Manufacturer/Supplier: Wieland Dental + Technik GmbH & Co. KG Lindenstr. 2 75175 Pforzheim Telefon +49 (0) 7231-37050, Telefax +49 (0) 7231-357959 · Further information obtainable from: [email protected] · 1.4 Emergency telephone number: GIZ-Nord, Göttingen, Germany +49 551 19240 Member of EPECS Network * SECTION 2: Hazards identification · 2.1 Classification of the substance or mixture · Classification according to Regulation (EC) No 1272/2008 GHS06 skull and crossbones Acute Tox. 2 H300 Fatal if swallowed. Acute Tox. 1 H310 Fatal in contact with skin. Acute Tox. 3 H331 Toxic if inhaled. GHS05 corrosion Skin Corr. 1C H314 Causes severe skin burns and eye damage. GHS09 environment Aquatic Chronic 2 H411 Toxic to aquatic life with long lasting effects. · Classification according to Directive 67/548/EEC or Directive 1999/45/EC T+; Very toxic R26/27/28: Very toxic by inhalation, in contact with skin and if swallowed. C; Corrosive R34: Causes burns. N; Dangerous for the environment R51/53: Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment. R32: Contact with acids liberates very toxic gas. · Information concerning particular hazards for human and environment: The product has to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in the latest valid version. (Contd. on page 2) GB 40.0 Page 2/10 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 17.04.2015 Version number 2 Revision: 17.04.2015 Trade name: Arcuplat Schnellversilberung m. 30g Ag/l Arcuplat silver bath with 30 g Ag/l (Contd. of page 1) · Classification system: The classification is according to the latest editions of the EU-lists, and extended by company and literature data. · 2.2 Label elements · Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation. · Hazard pictograms GHS05 GHS06 GHS09 · Signal word Danger · Hazard-determining components of labelling: potassium cyanide silver cyanide potassium carbonate · Hazard statements H300+H310 Fatal if swallowed or in contact with skin. H331 Toxic if inhaled. H314 Causes severe skin burns and eye damage. H411 Toxic to aquatic life with long lasting effects. · Precautionary statements P260 Do not breathe dust/fume/gas/mist/vapours/spray. P301+P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor. P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P405 Store locked up. P501 Dispose of contents/container in accordance with local/regional/national/international regulations. · Additional information: EUH032 Contact with acids liberates very toxic gas. · 2.3 Other hazards · Results of PBT and vPvB assessment · PBT: Not applicable. · vPvB: Not applicable. * SECTION 3: Composition/information on ingredients · 3.2 Chemical characterisation: Mixtures · Description: Mixture of substances listed below with nonhazardous additions. · Dangerous components: CAS: 151-50-8 potassium cyanide 5-10% EINECS: 205-792-3 T+ R26/27/28; N R50/53 R32 Acute Tox. 2, H300; Acute Tox. 1, H310; Acute Tox. 2, H330; Aquatic Acute 1, H400; Aquatic Chronic 1, H410 (Contd. on page 3) GB 40.0 Page 3/10 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 17.04.2015 Version number 2 Revision: 17.04.2015 Trade name: Arcuplat Schnellversilberung m. 30g Ag/l Arcuplat silver bath with 30 g Ag/l (Contd. of page 2) CAS: 584-08-7 potassium carbonate 1-5% EINECS: 209-529-3 Xn R22; Xi R36/37/38 Acute Tox. 4, H302; Skin Irrit. 2, H315; Eye Irrit. 2, H319; STOT SE 3, H335 CAS: 506-64-9 silver cyanide ≤ 5% EINECS: 208-048-6 T+ R26/27/28; N R50/53 R32 Acute Tox. 2, H300; Acute Tox. 1, H310; Acute Tox. 2, H330; Aquatic Acute 1, H400; Aquatic Chronic 1, H410 · Additional information: For the wording of the listed risk phrases refer to section 16. * SECTION 4: First aid measures · 4.1 Description of first aid measures · General information: Immediately remove any clothing soiled by the product. In case of irregular breathing or respiratory arrest provide artificial respiration. · After inhalation: Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. · After skin contact: Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor. · After eye contact: Rinse opened eye for several minutes under running water. Then consult a doctor. · After swallowing: Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately. · 4.2 Most important symptoms and effects, both acute and delayed No further relevant information available. · Hazards Danger of circulatory collapse. · 4.3 Indication of any immediate medical attention and special treatment needed No further relevant information available. * SECTION 5: Firefighting measures · 5.1 Extinguishing media · Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions. · 5.2 Special hazards arising from the substance or mixture In case of fire, the following can be released: Hydrogen cyanide (HCN) · 5.3 Advice for firefighters · Protective equipment: Wear self-contained respiratory protective device. * SECTION 6: Accidental release measures · 6.1 Personal precautions, protective equipment and emergency procedures Wear protective equipment. Keep unprotected persons away. · 6.2 Environmental precautions: Do not allow to enter sewers/ surface or ground water. · 6.3 Methods and material for containment and cleaning up: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dispose contaminated material as waste according to item 13. Ensure adequate ventilation. (Contd. on page 4) GB 40.0 Page 4/10 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 17.04.2015 Version number 2 Revision: 17.04.2015 Trade name: Arcuplat Schnellversilberung m. 30g Ag/l Arcuplat silver bath with 30 g Ag/l (Contd. of page 3) · 6.4 Reference to other sections See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information. * SECTION 7: Handling and storage · 7.1 Precautions for safe handling Ensure good ventilation/exhaustion at the workplace. Open and handle receptacle with care. · Information about fire - and explosion protection: Keep respiratory protective device available. · 7.2 Conditions for safe storage, including any incompatibilities · Storage: · Requirements to be met by storerooms and receptacles: Store only in the original receptacle. · Information about storage in one common storage facility: Do not store together with acids. Storage class 6.1 B (Non-combustible acutely toxic Cat. 1 and 2 substances) Only substances of the same storage class should be stored together. Collocated storage with the following substances is prohibited: - Pharmaceuticals, foods, and animal feeds including additives. - Infectious, radioactive und explosive substances. - Gases. - Flammable liquids of storage class 3. - Other explosive substances of storage class 4.1A. - Flammable solid substances or desensitized substances of storage class 4.1B. - Spontaneously flammable substances. - Substances liberating flammable gases in contact with water. - Strongly oxidizing substances of storage class 5.1A. - Ammonium nitrate and preparations containing ammonium nitrate. - Organic peroxides and self reactive substances. Under certain conditions the collocated storage with the following sub-stances is permitted (For more details see TRGS 510): - Oxidizing substances of storage class 5.1B. - Combustible solids of storage class 11. The substance should not be stored with substances with which ha-zardous chemical reactions are possible. (e.g. acids) · Further information about storage conditions: Keep receptacle tightly sealed. Store under lock and key and with access restricted to technical experts or their assistants only. · Storage class: LGK 6.1B · 7.3 Specific end use(s) No further relevant information available. * SECTION 8: Exposure controls/personal protection · Additional information about design of technical facilities: No further data; see item 7. · 8.1 Control parameters · Ingredients with limit values that require monitoring at the workplace: The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace. · DNELs 506-64-9 silver cyanide Oral DNEL(Com.)longterm 0.05 mg/kg (-) (CN) (Contd. on page 5) GB 40.0 Page 5/10 Safety data sheet according to 1907/2006/EC, Article 31 Printing date 17.04.2015 Version number 2 Revision: 17.04.2015 Trade name: Arcuplat Schnellversilberung m. 30g Ag/l Arcuplat silver bath with 30 g Ag/l (Contd. of page 4) DNEL(Comm.)akut 4.5 mg/kg (-) (CN) DNEL(Indust.)longt. 0.05 mg/kg (-) (CN) DNEL(Industrie) akut 4.5 mg/kg (-) (CN) · PNECs 506-64-9 silver cyanide PNEC (Commercial) 0.03 µg/l (H2O) (CN) PNEC (Industrie) 0.03 µg/l (H2O) (CN) · Additional information: The lists valid during the making were used as basis. · 8.2 Exposure controls · Personal protective equipment: · General protective and hygienic measures: Keep away from foodstuffs, beverages and feed. Immediately remove all soiled and contaminated clothing Wash hands before breaks and at the end of work.
Recommended publications
  • Chemical List
    1 EXHIBIT 1 2 CHEMICAL CLASSIFICATION LIST 3 4 1. Pyrophoric Chemicals 5 1.1. Aluminum alkyls: R3Al, R2AlCl, RAlCl2 6 Examples: Et3Al, Et2AlCl, EtAlCl2, Me3Al, Diethylethoxyaluminium 7 1.2. Grignard Reagents: RMgX (R=alkyl, aryl, vinyl X=halogen) 8 1.3. Lithium Reagents: RLi (R = alkyls, aryls, vinyls) 9 Examples: Butyllithium, Isobutyllithium, sec-Butyllithium, tert-Butyllithium, 10 Ethyllithium, Isopropyllithium, Methyllithium, (Trimethylsilyl)methyllithium, 11 Phenyllithium, 2-Thienyllithium, Vinyllithium, Lithium acetylide ethylenediamine 12 complex, Lithium (trimethylsilyl)acetylide, Lithium phenylacetylide 13 1.4. Zinc Alkyl Reagents: RZnX, R2Zn 14 Examples: Et2Zn 15 1.5. Metal carbonyls: Lithium carbonyl, Nickel tetracarbonyl, Dicobalt octacarbonyl 16 1.6. Metal powders (finely divided): Bismuth, Calcium, Cobalt, Hafnium, Iron, 17 Magnesium, Titanium, Uranium, Zinc, Zirconium 18 1.7. Low Valent Metals: Titanium dichloride 19 1.8. Metal hydrides: Potassium Hydride, Sodium hydride, Lithium Aluminum Hydride, 20 Diethylaluminium hydride, Diisobutylaluminum hydride 21 1.9. Nonmetal hydrides: Arsine, Boranes, Diethylarsine, diethylphosphine, Germane, 22 Phosphine, phenylphosphine, Silane, Methanetellurol (CH3TeH) 23 1.10. Non-metal alkyls: R3B, R3P, R3As; Tributylphosphine, Dichloro(methyl)silane 24 1.11. Used hydrogenation catalysts: Raney nickel, Palladium, Platinum 25 1.12. Activated Copper fuel cell catalysts, e.g. Cu/ZnO/Al2O3 26 1.13. Finely Divided Sulfides: Iron Sulfides (FeS, FeS2, Fe3S4), and Potassium Sulfide 27 (K2S) 28 REFERRAL
    [Show full text]
  • A Preliminary Risk-Based Screening Approach for Air Toxics Monitoring Data Sets U.S
    A Preliminary Risk-Based Screening Approach for Air Toxics Monitoring Data Sets U.S. Environmental Protection Agency Air, Pesticides, and Toxics Management Division Atlanta, Georgia 30303 EPA-904-B-06-001 www.epa.gov/region4/air/airtoxic/ October 2010 Cover Photo: Greg Noah/EPA (Version 2) Disclaimer The information and procedures set forth here are intended as a technical resource to those conducting risk-based evaluations of air toxics monitoring data. This document does not constitute rulemaking by the Agency, and cannot be relied on to create a substantive or procedural right enforceable by any party in litigation with the United States. As indicated by the use of non-mandatory language such as “may” and “should,” it provides recommendations and does not impose any legally binding requirements. In the event of a conflict between the discussion in this document and any Federal statute or regulation, this document would not be controlling. The general description provided here may not apply to a particular situation based upon the circumstances. Interested parties are free to raise questions and objections about the substance of this methodology and the appropriateness of its application to a particular situation. EPA Region 4 and other decision makers retain the discretion to adopt approaches on a case-by-case basis that differ from those described in this document where appropriate. EPA Region 4 may take action that is at variance with the recommendations and procedures in this document and may change them at any time without public notice. This is a living document and may be revised periodically. EPA Region 4 welcomes public input on this document at any time.
    [Show full text]
  • NMR Studies of Phosphorus Ligand Complexes of Silver and Cobalt Steven Mark Socol Iowa State University
    Iowa State University Capstones, Theses and Retrospective Theses and Dissertations Dissertations 1983 NMR studies of phosphorus ligand complexes of silver and cobalt Steven Mark Socol Iowa State University Follow this and additional works at: https://lib.dr.iastate.edu/rtd Part of the Inorganic Chemistry Commons Recommended Citation Socol, Steven Mark, "NMR studies of phosphorus ligand complexes of silver and cobalt " (1983). Retrospective Theses and Dissertations. 8962. https://lib.dr.iastate.edu/rtd/8962 This Dissertation is brought to you for free and open access by the Iowa State University Capstones, Theses and Dissertations at Iowa State University Digital Repository. It has been accepted for inclusion in Retrospective Theses and Dissertations by an authorized administrator of Iowa State University Digital Repository. For more information, please contact [email protected]. INFORMATION TO USERS This reproduction was made from a copy of a document sent to us for microfilming. While the most advanced technology has been used to photograph and reproduce this document, the quality of the reproduction is heavily dependent upon the quality of the material submitted. The following explanation of techniques is provided to help clarify markings or notations which may appear on this reproduction. 1.The sign or "target" for pages apparently lacking from the document photographed is "Missing Page(s)". If it was possible to obtain the missing page(s) or section, they are spliced into the film along with adjacent pages. This may have necessitated cutting through an image and duplicating adjacent pages to assure complete continuity. 2. When an image on the film is obliterated with a round black mark, it is an indication of either blurred copy because of movement during exposure, duplicate copy, or copyrighted materials that should not have been filmed.
    [Show full text]
  • Chemical Names and CAS Numbers Final
    Chemical Abstract Chemical Formula Chemical Name Service (CAS) Number C3H8O 1‐propanol C4H7BrO2 2‐bromobutyric acid 80‐58‐0 GeH3COOH 2‐germaacetic acid C4H10 2‐methylpropane 75‐28‐5 C3H8O 2‐propanol 67‐63‐0 C6H10O3 4‐acetylbutyric acid 448671 C4H7BrO2 4‐bromobutyric acid 2623‐87‐2 CH3CHO acetaldehyde CH3CONH2 acetamide C8H9NO2 acetaminophen 103‐90‐2 − C2H3O2 acetate ion − CH3COO acetate ion C2H4O2 acetic acid 64‐19‐7 CH3COOH acetic acid (CH3)2CO acetone CH3COCl acetyl chloride C2H2 acetylene 74‐86‐2 HCCH acetylene C9H8O4 acetylsalicylic acid 50‐78‐2 H2C(CH)CN acrylonitrile C3H7NO2 Ala C3H7NO2 alanine 56‐41‐7 NaAlSi3O3 albite AlSb aluminium antimonide 25152‐52‐7 AlAs aluminium arsenide 22831‐42‐1 AlBO2 aluminium borate 61279‐70‐7 AlBO aluminium boron oxide 12041‐48‐4 AlBr3 aluminium bromide 7727‐15‐3 AlBr3•6H2O aluminium bromide hexahydrate 2149397 AlCl4Cs aluminium caesium tetrachloride 17992‐03‐9 AlCl3 aluminium chloride (anhydrous) 7446‐70‐0 AlCl3•6H2O aluminium chloride hexahydrate 7784‐13‐6 AlClO aluminium chloride oxide 13596‐11‐7 AlB2 aluminium diboride 12041‐50‐8 AlF2 aluminium difluoride 13569‐23‐8 AlF2O aluminium difluoride oxide 38344‐66‐0 AlB12 aluminium dodecaboride 12041‐54‐2 Al2F6 aluminium fluoride 17949‐86‐9 AlF3 aluminium fluoride 7784‐18‐1 Al(CHO2)3 aluminium formate 7360‐53‐4 1 of 75 Chemical Abstract Chemical Formula Chemical Name Service (CAS) Number Al(OH)3 aluminium hydroxide 21645‐51‐2 Al2I6 aluminium iodide 18898‐35‐6 AlI3 aluminium iodide 7784‐23‐8 AlBr aluminium monobromide 22359‐97‐3 AlCl aluminium monochloride
    [Show full text]
  • Cyanide Reduction in Bright Stripping Using an Electrolytic Process
    THE MASSACHUSETTS TOXICS USE REDUCTION INSTITUTE CYANIDE REDUCTION IN BRIGHT STRIPPING USING AN ELECTROLYTIC PROCESS THE ROBBINS COMPANY Technical Report No. 18 University of Massachusetts Lowell Cyanide Reduction in Bright Stripping Using an Electrolytic Process The Robbins Company Lew Reed Environmental Systems Engineer The Robbins Company Attleboro, Massachusetts The Toxics Use Reduction Institute Matching Grants Program December 1994 The Toxics Use Reduction Institute University of Massachusetts Lowell I IAll rights to this report belong to the Toxics Use Reduction Institute. The m m material may be duplicated with permission by contacting the Institute. rn The Toxics Use Reduction Institute is a multidisciplinary research, education, and policy center established by the Massachusetts Toxics Use Reduction Act of 1989. The Institute sponsors and conducts research, organizes education and training programs, and provides technical support to promote the reduction in the use of toxic chemicals or the generation of toxic chemical byproducts in industry and commerce. Further information can be obtained by writing the Toxics Use Reduction Institute, University of Massachusetts Lowell, One University Avenue, Lowell, Massachusetts 01854. qoxics Use Reduction Institute, University of Massachusetts Lowell Toxics Use Reduction Institute Matching Grants Program The Institute annually provides direct funding to Massachusetts industries on a matching basis for toxics use reduction (TUR) feasibility and technology studies. The matching Grants Program was initiated in FY 93 to facilitate the development and use of innovative techniques that reduce the use of toxic chemicals or the generation of toxic byproducts in Massachusetts businesses. Grants are awarded on a competitive basis for companies to conduct TUR studies at their facilities.
    [Show full text]
  • Interagency Committee on Chemical Management
    DECEMBER 14, 2018 INTERAGENCY COMMITTEE ON CHEMICAL MANAGEMENT EXECUTIVE ORDER NO. 13-17 REPORT TO THE GOVERNOR WALKE, PETER Table of Contents Executive Summary ...................................................................................................................... 2 I. Introduction .......................................................................................................................... 3 II. Recommended Statutory Amendments or Regulatory Changes to Existing Recordkeeping and Reporting Requirements that are Required to Facilitate Assessment of Risks to Human Health and the Environment Posed by Chemical Use in the State ............................................................................................................................ 5 III. Summary of Chemical Use in the State Based on Reported Chemical Inventories....... 8 IV. Summary of Identified Risks to Human Health and the Environment from Reported Chemical Inventories ........................................................................................................... 9 V. Summary of any change under Federal Statute or Rule affecting the Regulation of Chemicals in the State ....................................................................................................... 12 VI. Recommended Legislative or Regulatory Action to Reduce Risks to Human Health and the Environment from Regulated and Unregulated Chemicals of Emerging Concern ..............................................................................................................................
    [Show full text]
  • Cyanide Destruction/ Immobilization of Residual Sludge
    Cyanide Destruction/ Immobilization of Residual Sludge Mixed Waste Focus Area Prepared for U.S. Department of Energy Office of Environmental Management Office of Science and Technology February 1998 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. Cyanide Destruction/ Immobilization of Residual Sludge OST Reference # 1425 Mixed Waste Focus Area Demonstrated at U.S. Department of Energy Rocky Flats Environmental Technology Site Golden, Colorado Purpose of this document Innovative Technology Summary Reports are designed to provide potential users with the information they need to quickly determine if a technology would apply to a particular environmental management problem. They are also designed for readers who may recommend that a technology be considered by prospective users. Each report describes a technology, system, or process that has been developed and tested with funding from DOE’s Office of Science and Technology (OST).
    [Show full text]
  • The Analysis of Cyanide Silver-Plating Solutions
    RP384 THE ANALYSIS OF CYANIDE SILVER-PLATING SOLUTIONS By R. M. Wick ABSTRACT Methods for the analysis of cyanide silver-plating solutions were studied, including the determination of free cyanide, total cyanide, carbonate, chloride, ammonia, silver, iron, copper, and mercury. Electrometric titrations showed that the Liebig method for alkali cyanide is correct to better than 0.2 per cent. Addition of iodide makes the method still more accurate and overcomes the effects of impurities on the titration. The nonagreement of the Liebig and Hannay methods was studied by electro- metric titrations, which showed that the visual Hannay method gives high results although the electrometric Hannay titration is accurate. The determination of total cyanide was accomplished by distillation with sulphuric acid, and of total effective cyanide by titration with iodine. Silver may be separated as silver sulphide, by precipitation with zinc, or by decomposition with acid, after which a determination by any standard method is applicable. Carbonate may be determined by precipitating and filtering out barium car- bonate and titrating it with acid or by titrating a sample with acid after adding silver nitrate to combine with the free cyanide. The usual method for the determination of chloride involves prolonged treat- ment with nitric acid, which converts the precipitated silver cyanide to silver chloride. A new method for separating chloride was investigated in which the silver is precipitated as sulphide and the iron is removed by precipitation as manganous ferrocyanide. The chloride in the filtrate can be determined by the usual methods. Iron and copper can be determined by the regular analytical methods after decomposition of the plating solution with sulphuric acid.
    [Show full text]
  • EPA's Hazardous Waste Listing
    Hazardous Waste Listings A User-Friendly Reference Document September 2012 Table of Contents Introduction ..................................................................................................................................... 3 Overview of the Hazardous Waste Identification Process .............................................................. 5 Lists of Hazardous Wastes .............................................................................................................. 5 Summary Chart ............................................................................................................................... 8 General Hazardous Waste Listing Resources ................................................................................. 9 § 261.11 Criteria for listing hazardous waste. .............................................................................. 11 Subpart D-List of Hazardous Wastes ............................................................................................ 12 § 261.31 Hazardous wastes from non-specific sources. ............................................................... 13 Spent solvent wastes (F001 – F005) ......................................................................................... 13 Wastes from electroplating and other metal finishing operations (F006 - F012, and F019) ... 18 Dioxin bearing wastes (F020 - F023, and F026 – F028) .......................................................... 22 Wastes from production of certain chlorinated aliphatic hydrocarbons (F024
    [Show full text]
  • Silver Glo™ 3Kbp
    SILVER GLO™ 3KBP WITH SILVER GLO 33BP For Electronic Finishing Applications Regional Product Availability BATH MAKE-UP—Rack and Barrel Formulation N.America Japan/Korea Asia Europe Chemicals Required Metric (U.S.) Silver Metal as Silver: 33 g/l (4.4 tr. oz./gal.) ✔ Cyanide (80.5%) Potassium Carbonate: 15–30 g/l (2–4 oz./gal.) (K CO ) DESCRIPTION 2 3 Silver Glo 3KBP: 10–30 ml/l (1–3% v/v) The Rohm and Haas Electronic Materials Silver Glo 3KBP process is designed to produce bright silver Silver Glo TY or 1–5 ml/l (0.1–0.5% v/v) deposits over a wide range of current densities (0–70 Silver Glo SX: amps/ft2), with high cathode efficiency and simplicity of Potassium Cyanide: 113 g/l (15 oz./gal.) process control. The 3KBP is suitable for all decorative applications and rack and barrel operations. Silver 3KBP Starter Salt: 10 g/l (1.3 oz./gal.) deposits from the 3KBP have superior tarnish resistance compared to other silver plating processes. BATH OPERATION ADVANTAGES Metric (U.S.) Silver Metal as Silver: 33 g/l (4.4 tr. oz./gal.) • The 3KBP solution can be used in decorative Cyanide (80.5%) applications, rack and barrel • Ease of control Potassium Cyanide: 113 g/l (15.0 oz./gal.) • Clear, water-white solution for easy viewing of work Temperature: 21–29ºC (70–85ºF) during plating Agitation: (18 ft./min.) Current Density Range: 0–7 ASD (0–70 amps/ft.2) Silver Strike As is customary in silver plating, a Silver Strike should be used prior to plating.
    [Show full text]
  • Safety Data Sheet
    SAFETY DATA SHEET Creation Date 05-Sep-2014 Revision Date 02-Feb-2021 Revision Number 3 SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1. Product identifier Product Description: Potassium silver cyanide Cat No. : 12551 Synonyms Potassium dicyanoargentate CAS-No 506-61-6 Molecular Formula C2 Ag K N2 Reach Registration Number - 1.2. Relevant identified uses of the substance or mixture and uses advised against Recommended Use Laboratory chemicals. Uses advised against No Information available 1.3. Details of the supplier of the safety data sheet Company Alfa Aesar . Avocado Research Chemicals, Ltd. Shore Road Port of Heysham Industrial Park Heysham, Lancashire LA3 2XY United Kingdom Office Tel: +44 (0) 1524 850506 Office Fax: +44 (0) 1524 850608 E-mail address [email protected] www.alfa.com Product Safety Department 1.4. Emergency telephone number Call Carechem 24 at +44 (0) 1865 407333 (English only); +44 (0) 1235 239670 (Multi-language) SECTION 2: HAZARDS IDENTIFICATION 2.1. Classification of the substance or mixture CLP Classification - Regulation (EC) No 1272/2008 Physical hazards Based on available data, the classification criteria are not met Health hazards ______________________________________________________________________________________________ ALFAA12551 Page 1 / 11 SAFETY DATA SHEET Potassium silver cyanide Revision Date 02-Feb-2021 ______________________________________________________________________________________________ Acute oral toxicity Category 2 (H300) Acute dermal toxicity Category
    [Show full text]
  • Hydrogen Cyanide and Cyanides: Human Health Aspects
    This report contains the collective views of an international group of experts and does not necessarily represent the decisions or the stated policy of the United Nations Environment Programme, the International Labour Organization, or the World Health Organization. Concise International Chemical Assessment Document 61 HYDROGEN CYANIDE AND CYANIDES: HUMAN HEALTH ASPECTS Please note that the layout and pagination of this pdf file are not identical to the version in press First draft prepared by Prof. Fina Petrova Simeonova, Consultant, National Center of Hygiene, Medical Ecology and Nutrition, Sofia, Bulgaria; and Dr Lawrence Fishbein, Fairfax, Virginia, USA Published under the joint sponsorship of the United Nations Environment Programme, the International Labour Organization, and the World Health Organization, and produced within the framework of the Inter-Organization Programme for the Sound Management of Chemicals. World Health Organization Geneva, 2004 The International Programme on Chemical Safety (IPCS), established in 1980, is a joint venture of the United Nations Environment Programme (UNEP), the International Labour Organization (ILO), and the World Health Organization (WHO). The overall objectives of the IPCS are to establish the scientific basis for assessment of the risk to human health and the environment from exposure to chemicals, through international peer review processes, as a prerequisite for the promotion of chemical safety, and to provide technical assistance in strengthening national capacities for the sound management
    [Show full text]