AxisPro™ Servo-Performance Proportional Directional Valve with Feedback KBS*DG4V-3 Pressures to 350 bar (5000 psi) 10 Series Contents

Introduction General Description...... 3 Typical Section View...... 3 Model Code...... 4 Spool Data...... 6 Functional Symbol...... 6 Pressures and Flow Rates...... 6 Operating Data ...... 7 Performance Curves Flow Gain...... 9 Pressure Gain...... 9 Power Capacity Envelopes...... 9 Frequency Response...... 10 Installation Dimension KBS*DG4V-3...... 11 Mounting Surface...... 13 Electrical Information...... 14 Software Information...... 18 Application Data Fluid Cleanliness...... 19 Hydraulic Fluids...... 19 Installation...... 19 Mounting Bolt Kits...... 19 Seal Kits...... 19 Electrical Connectors...... 19 Service Information...... 19

Note: At this preliminary stage, the performance data communicated hereunder are indicative only and they are subject to further testing and subsequent changes by Eaton. Kindly note that the product performance may also depend on the customer’s application/environment.

2 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Introduction

EAxisProaton’s ™N Eaton’sext Ge nNexterat Generationion Propo rtProportionalional Valve Valve Eaton’s Next Generation Proportional Valve Next Generation Open Architecture - Designed to work in Centralized and Distributed control solutions. Open Architecture - Designed to enable custom solutions.

Built on the proven KB Servo Proportional Valve technology, Proportional Valves Modular Eaton’s Next Generation proportional valve provides 4 levels in a Flexibility modular design. Order exactly what the application demands. Centralized Control Eaton CONTROL F(x) Programming Software

Axis 1 PLC X

Centralized Control Junction Profile 1 Power and Differentiation Distributed Control PID Make It Yours! Create custom control programs for next generation Control 1 3X Analog Valve Box proportional valves with Eaton CONTROL F(x)™, and upload your Performance Flexibility Command, X control application code to the on-board axis controller to achieve • Higher reliability and durability • Better control performance • Flexible control strategy using • Differentiated machine Feedback, Enable built-in sensors performance Profile 2 differentiated machine performance. Designed around open • On-board high performance, • Modular design • Flexibility • Wiring savings PID standards and based on the IEC-61131-3 programming standard, independent axis controller • Easy diagnosis • Machine scalability • More diagnosis data available Axis 2 Control 2 • Configurability from sensors 3X Analog Cylinder Eaton CONTROL F(x)™ is a Windows-based tool that lets you Feedback • Open architecture controller for • More robust • Comprehensive diagnostic data X design and develop high performance distributed axis control • Supports multiple architectures available via field bus customer application program KBS4 Profile 3 systems. Use Eaton-developed function blocks for or create your • PQ control function PID own to enable even more rapid, reliable development. With Control 3 Control F(x) and Eaton’s next generation proportional valves, your • “White Space” for IF (Axis 1 Complete) imagination and creativity are enabled to achieve differentiated KBS3 Customer Applications Axis 3 {Axis 2} ELSE solutions. Reliability Easy Diagnostics {Wait} Sequencing Logic • Best in class dirt and moisture • Comprehensive LED indicators • Embedded Pressure ingression protection, IP65 & 67 KBS2 & Temperature Sensors • Field bus communication on all 4 Ports PLC • Best in class ambient temp • Built-in pressure/temp sensors rating 85°C • Bus Communication, • No air bleeding KBS1 Hard Coded Axis Controller, PQ • CE electromagnetic compliance Distributed Control Fieldbus: Start Profile • Configurable PLC • Higher Flow and Pressure Rating Profile Complete IF (Axis 1 Junction • IP65 & 67 Rating Fault Status Complete) Axis 1 Optional broadcast of {Axis 2} • Ambient Temp up to 85°C sensed signals ELSE Box {Wait} • No Air Bleeding X • Comprehensive LED Profile 1 Six language editor, visualization capabilities and real-time debugging and simulation make CONTROL F(x) PID an efficient, extremely effective tool. Control 1 PLC Axis 2 Components Editors for programming in: X Eaton’s Next Generation Proportional Directional Valve • Library management for user • Instruction list Profile 2 defined libraries PID • Sequential function chart LED Indicators General DescriptionD03 and D05 are smart axis control subsystem featuring: Control 2 • Run time system in ANSI-C for • Function block diagram These four-way solenoid operated proportional valves offer flow control, debugging and Built on the proven KB Servo Proportional Valve technology, communication • Structured text External Sensor Analog Connection, • Servo performance level ISO-3 Size ISO-5 Size Eaton’s Next Generation proportional valve provides 4 levels high dynamic performance which enables them to be used Axis 3 X • Ladder diagram Connector, 7-pin DIN • Visualization elements • 4-level modular design Rated Flow 40 LPM @ 70 bar 100 LPM @ 70 bar M12x5 pin, of performance in a modular design. in closed loop applications previously only possible using Profile 3 • Code Generators for multiple • Continuous function chart up to 4 Sensors • On-board amplifier and axis Max Flow 75 LPM 180 LPM PID processors controller conventional servo valves. Control 3 CANbus, M12x5 pin Dynamic Bandwidth 150 Hz 100 Hz • Complete offline simulation • Open architecture axis controller Online functionality: CANbus 1 (customer applications) Step Response 8 ms 18 ms • Hierarchical graphical M12x5 pin Typical Section View configuration • Monitoring of all variables Cover for Sensors • Embedded sensors Hysteresis 0.1% 0.1% • DDE Server, OPC Server • Writing and forcing of receipts • Field bus communication Linearity 1% 1% (sets of variables) CANbus 2 • Improved flow and pressure ™ ™ Distributed Axis Control, • Debugging your complete M12x5 pin Valve F(x) / Control F(x) Temperature 85°C Ambient 85°C Ambient • More robust design (best in class) (best in class) Eaton Two Solutions: project (breakpoints, stepping, • Hard-coded Algorithms per single cycle, call stack) 85°C Hydraulic 85°C Hydraulic Industry standard GUI Connector (best in class) (best in class) • Interrupt-free online changes • Eaton Control F(x) = “White of POUs and data Pressure 350 bar P, A 350 bar P, A Space” for customer’s writing • Power Flow and B port and B port proprietary control algorithms. • Sampling Trace 250 bar T port 250 bar T port LVDT Proportional Solenoid Environmental Protection IP65 & 67 IP65 & 67 (best in class) (best in class)

EATON Next Generation Proportional Valves V-VLPO-MR005-EN1 March 2011

KBS1DG4V-3

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 3 Model Code

KBS 1 D G 4 V - 3 - 9 * - ** - M* F* - P*7 - H - 8 - 10

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 Valve Type 8 Spool type, center 11 Command Signal 13 Electrical Connection KBS – Servo performance condition M1 - +/- 10V voltage PC7 – 7 pin connector with- proportional valve with inte- 9 – Zero underlap command signal out plug gral amplifier and electronic M2 - 4-20mA current PE7 – 7 pin connector with feedback 9 Spool type, spring off- plug set command signal 2 1 – Configurable via PC condition M3 - +/- 10mA current PH7 – As PE7 but with pin 2 – P,A,B,T blocked command signal “C” used for enable signal 6 – P blocked, A & B to tank 3 Control Type M4 - +/- 15mA current PR7 – As PC7 but with pin D – Directional valve command signal “C” used for enable signal 10 Rated flow at 70 bar (1000 psi) loop Δp pressure 4 Mounting 14 Electrical Power drop 12 Feedback Signal G – Subplate mounted H – 24V DC amplifier supply 05 – 5 L/min (1.3 USgpm) F1 - ±10V voltage feedback 12 – 12 L/min (3.2 USgpm) signal 5 Operation 24 – 24 L/min (6.3 USgpm) 15 Port T Pressure limit F2 - 4-20mA current feed- 4 – Solenoid operated 40 – 40 L/min (10.6 USgpm) Code back signal 8 – for all spools 6 Pressure Rating For actual maximum flow F3 - ±10mA current feed- V – 350 bar (5000 psi) refer to Power capacity enve- back signal 16 Design Number lope curves, page 8. F4 - ±15mA current feed- 10 series. 7 Interface back signal 3 – ISO 4401, size 03-02-0-94 ANSI/B93.7M-D03

4 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Model Code

KBS * D G 4 V - 3 - 9 * L - ** - M* F* - P*7 - H - 8 - ** - * *** - 10

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

2 12 Feedback Signal D - 1 SSI external digital sen- 19 Design Number 2 – Level 1 PLUS Network F1 - ±10V voltage feedback sor input 10 series. enabled and DS408 control signal Omit - No external sensor Refer to previous model code on page 4 for modes inputs F2 - 4-20mA current feed- other model code option. 3 – Level 2 PLUS Integrated back signal Pressure Transducers F3 - ±10mA current feed- 18 back signal DPC - DS408 Drive Position Control Mode Enabled 11 Command Signal F4 - ±15mA current feed- M1 - +/- 10V voltage back signal DSC - DS408 Drive Speed Control Mode Enabled command signal F9 - Feedback over Fieldbus M2 - 4-20mA current DFP - DS408 Drive Force/ command signal Pressure Control Mode 16 Enabled M3 - +/- 10mA current CO – CANOpen command signal DPQ - Eaton Custom Drive Omit – No digital communi- Pressure / Flow Control M4 - +/- 15mA current cation interface Mode Enabled command signal Omit - Valve spool closed M9 - Command over Fieldbus 17 loop position control (VSC) A - 4 4-20mA external sensor analog inputs and 2 discrete inputs

KBS * D G 4 V - 3 - 9 * L - ** - M* F* - P*7 - H - 8 - ** - * *** *** - 10

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

2 19 (Only for level 4) 20 Design Number Refer to previous model code on page 4 for 4 – Level 3 PLUS on-board LFB - Local CANOpen field- 10 series. other model code option. application controller. bus Omit - No local CANOpen fieldbus

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 5 Spool Data Spool Symbols

Functional Symbol

Model Type KBS1DG4V-3 Model Type KBS2DG4V-3

Model Type KBS3DG4V-3 Model Type KBS4DG4V-3

Spool Types and Flow Symmetric Spools Spool Code Spool Symbol Flow Rating Ratings Base line pressure drop Δp = For KBS*DG4V-3 valves: 35 bar (500 psi) per metering 92L05 92L 5 L/min (1.3 USgpm) flow path, e.g. B to T. For 92L12 92L 12 L/min (3.2 USgpm) actual maximum flow refer 92L24 92L 24 L/min (6.3 USgpm) to power capacity envelope 92L40 92L 40 L/min (10.6 USgpm) curves. 96L05 96L 5 L/min (1.3 USgpm) 96L12 96L 12 L/min (3.2 USgpm) 96L24 96L 24 L/min (6.3 USgpm) 96L40 96L 40 L/min (10.6 USgpm)

Pressures and Flow Rates Ports Operating Pressure: P,A,B : 350 (5075) bar (psi) T: 250(3625)

Spool type 92L Spool type 96L

6 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Operating Data

Connector Details 7-pin plug connector Pin Description Note: A G A Power supply positive (+) Present at location 1 of the electronics B Power supply 0V and current command return enclosure (see figure 1 below). F B C Not connected (PE7 & PC7) To ensure EMI protection use only metal shielded C Valve enable (PH7 & PR7) mating connectors D Command signal (+V or current in) E C E Command signal (-V or current GND) F Output monitor G Protective earth D

M12 5-pin CAN Connector (Male) Pin Description Note: 4 1 Power supply 0V Present at location 2 and 4 of the electronics 2 Not Connected enclosure (see figure 1 below). Selection based on 5 3 Power supply 0V model code field number 16, present when CO 4 CAN High option enabled. 1 3 5 CAN Low To ensure EMI protection use only metal shielded mating connectors Use only shielded twisted pair (STP) cables for 2 mating connection. M12 5-pin CAN Connector (Female) Pin Description Note: 2 1 Power supply 0V Present at location 2 and 4 of the electronics 5 2 Not Connected enclosure (see figure 1 below). Selection based on 3 Power supply 0V model code field number 16, present when CO 1 3 4 CAN High option enabled. 5 CAN Low To ensure EMI protection use only metal shielded mating connectors Use only shielded twisted pair (STP) cables for 4 mating connection. 8-pin SSI Connector Pin Description Note: 6 1 Power supply 0V Present at location 3 of the electronics 7 5 2 +24V Supply enclosure (see figure 1 below). Selection based on 3 CLK- model code field number 17, present when D 8 4 DATA- option enabled. 5 DATA+ To ensure EMI protection use only metal shielded 4 6 Not Connected mating connectors 7 CLK+ 24V to Power supply 0V (pin 2, 1) short circuit 1 3 8 Not Connected protected (max current 1.5 A). 2 Use only shielded twisted pair (STP) cables for mating connection. 8-pin External Sensor Signal Conditioner Pin Description Note: 6 1 Speed Sensor Input1 Present at location 3 of the electronics 2 Speed Sensor Input2 enclosure (see figure 1 below). Selection based on 7 5 3 4-20mA External Sensor Signal1 model code field number 17, present when A 8 4 +15V Supply option enabled. 5 4-20mA External Sensor Signal2 To ensure EMI protection use only metal shielded 4 6 Power supply 0V mating connectors 7 4-20mA External Sensor Signal3 15V to Power supply 0V (pin 4, 6) short circuit 1 3 8 4-20mA External Sensor Signal4 protected (max current 500 mA). 2

Location 1 Location 3 Location 4 Location 2 Location 5

Figure 1

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 7 Operating Data

Data is typical, with fluid at 36 cST (168 SUS) and 50°C (122°F) Diagnostic Color Description A [Green] Power B [Red] CAN Error C [Green] CAN Run D [Red] Diagnostic E [Green] Status

Note: LEDs F, G, H will glow as they are part of general operation

Electromagnetic compatibility (EMC): IEC61326-2-1 Zero adjustment ±18% mechanical adjustment accessible under plug in LVDT Monitor points signal Voltage mode ±10V DC Output impedance 10 kΩ Power stage PWM frequency 20 kHz nominal Reproducibility, valve-to-valve (at factory settings): Flow gain at 100% command signal ≤5% Protection: Electrical Reverse polarity protected between pin A and B of the 7 pin plug connector Ambient air temperature range for full performance -25°C to +85°C (-13°F to +185°F) Oil temperature range for full performance -25°C to +85°C (-13°F to +185°F) Minimum temperature at which valves will work at reduced performance –20°C (–4°F) Storage temperature range –25°C to +85°C (–13°F to +185°F) Power supply 24V DC (18V to 36V including 10% peak-to-peak max ripple) max current 3,7A Command signal Voltage mode –10V to +10V DC Input impedance M1: 47 kΩ - M2, M3, M4: 100Ω Voltage between Pin D and B M1: 18V (max) Voltage between Pin E and B M1: 18V (max) Current mode M2: 4-20 mA , M3: +/-10mA, M4: +/-15mA Max differential voltage to pin E to pin B M2, M3, M4: 100 mV Valve enable signal for model code PH7 & PR7 Enable Disable >8.5V (36V max) <6.5V Input impedance 10 kΩ Sensor Resolution 2.5% of 400 bar full scale rating

KBS*DG4V3 Valves (all valves) Relative duty factor Continuous rating (ED = 100%) Hysteresis <0.5% Step response: Step size (% of max spool stroke): Time to reach 90% of required step: 0-100% or 100-0% 10 mS 10-90% or 90-10% 6 ±10% to ±10% 4 ±25% to ±25% 5 Mass: KBS*DG4V-3 2,49 kg (5.5 lb) approx.

8 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Performance Curves

Flow Gain Pressure Gain Flow from port P-A-B-T or P-B-A-T at 70 bar (1000 psi) total Δp between ports A and B or B and A, as % of port P pres- valve Δp, 35 bar (500 psi) per metering edge sure

USgpmL/min 12 40

10 30 8

L40 Spool 6 20 low Rate F L24 Spool 4 10 L12 Spool 2 L05 Spool Spool stroke from null, % of max. 0 0 0 20 40 60 80 100 Command Signal (% of max)

Power Capacity Envelopes

KBS*DG4V-3-9*L-05 Valves KBS*DG4V-3-9*L-12 Valves

Type 92 spool

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 9 Performance Curves

Power Capacity Envelopes KBS*DG4V-3-9*L-24 Valves KBS*DG4V-3-9*L-40 Valves

Type 9* Spool

Frequency Response, typical For amplitudes of ±5%, ±25, ±100% with zero offset. Δp (P to T) = 70 bar (1000 psi)

0

-15 0 3 -30 -15 0 -30 -45 -45 -3 -60 -60

-75 -75 -6 Phase [deg] Phase [deg] -90 Magnitude [dB] -90 -105 -9 -105 -120 -135 -12 -120 110100 1000 110 100 1000 Frequency [Hz] -135 Frequency [Hz] 1 10 100 1000 Frequency [Hz]

3

0

-3

-6 Magnitude [dB] Magnitude

-9

-12 1 10 100 1000 Frequency [Hz] ±5% ±25% ±100%

10 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 7 - PIN CONNECTOR PLUG

128.85 [5.07] 7 - PIN CONNECTOR PLUG

Installation Dimensions mm (inch) 46 21.75 14 [0.54] [1.81] [0.86] 159 [6.26] 227 [8.95] 128.85 [5.07] KBS1DG4V-3 249 [9.82]

7 - PIN CONNECTOR PLUG

21.75 46.0 [0.86] 13.75 [0.54] [1.81] 159.05 [6.26] 227.30 [8.95] 249.35 [9.82]

128.85 [5.07]

46.0 21.75 13.75 [0.54] [1.81] [0.86] 146.1 [5.75] 214.35 [8.44] 236.4 [9.31]

7 - PIN CONNECTOR PLUG

KBS2DG4V-3

7 - PIN CONNECTOR PLUG

128.85 [5.07]

128.85 [5.07] 7 - PIN CONNECTOR PLUG 46.0 21.75 13.75 [0.54] [1.81] [0.86] 159.05 [6.26] 227.30 [8.95] 249.35 [9.82]

46 21.75 14 [0.54] [1.81] [0.86] 159 [6.26] 227 [8.95] 128.85 [5.07] 249 [9.82]

7 - PIN CONNECTOR PLUG

21.75 46.0 [0.86] 13.75 [0.54] [1.81] 159.05 [6.26]

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 11 227.30 [8.95] 249.35 [9.82]

128.85 [5.07]

46.0 21.75 13.75 [0.54] [1.81] [0.86] 146.1 [5.75] 214.35 [8.44] 236.4 [9.31]

7 - PIN CONNECTOR PLUG

128.85 [5.07]

46.0 21.75 13.75 [0.54] [1.81] [0.86] 159.05 [6.26] 227.30 [8.95] 249.35 [9.82] 7 - PIN CONNECTOR PLUG

128.85 [5.07] 7 - PIN CONNECTOR PLUG

46 21.75 14 [0.54] [1.81] [0.86] 159 [6.26] 227 [8.95] 128.85 [5.07] 249 [9.82]

7 - PIN CONNECTOR PLUG

21.75 46.0 [0.86] 13.75 [0.54] [1.81] 159.05 [6.26] 227.30 [8.95] 249.35 [9.82]

128.85 [5.07]

Installation Dimensions mm (inch)

46.0 21.75 13.75 [0.54] [1.81] [0.86] 146.1 [5.75] 214.35 [8.44] KBS3DG4V-3 236.4 [9.31]

7 - PIN CONNECTOR PLUG

128.85 [5.07]

46.0 21.75 13.75 [0.54] [1.81] [0.86] 159.05 [6.26] 7 - PIN CONNECTOR PLUG 227.30 [8.95] 249.35 [9.82]

KBS4DG4V-3

128.85 [5.07] 7 - PIN CONNECTOR PLUG

46 21.75 14 [0.54] [1.81] [0.86] 159 [6.26] 227 [8.95] 128.85 [5.07] 249 [9.82]

7 - PIN CONNECTOR PLUG

21.75 46.0 [0.86] 13.75 [0.54] [1.81] 159.05 [6.26] 227.30 [8.95] 249.35 [9.82]

128.85 [5.07]

46.0 21.75 13.75 [0.54] [1.81] [0.86] 146.1 [5.75] 12 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 214.35 [8.44] 236.4 [9.31]

7 - PIN CONNECTOR PLUG

128.85 [5.07]

46.0 21.75 13.75 [0.54] [1.81] [0.86] 159.05 [6.26] 227.30 [8.95] 249.35 [9.82] Mounting Surfaces

Mounting Surfaces to ISO 401 (Size 03) 30,2 4 holes, M5-6H x 12 (0.47) This interface conforms to: (1.18) min. full thread depth ISO 4401-03-02-0-94 plus location pin hole 21,5 (0.85) ANSI/B93.7M (and NFPA) size 03 12,7 0,75 0,1 CETOP R35H4.2-4-03, plus (0.5) (0.03 0.004) location pin hole 5,1 (0.20) DIN 24340 Form A6 plus T location pin hole 15,5 (0.61) 25,9 (1.01) A 31,0 0,1 48 (1.89) min. (1.22 0.004) B 31,75 0,1 (1.25 0.004) P 4 ports Ø 6,3 (0.25 dia). For all Vickers size 03 valves this diameter may be increased 7,5 (0.29) to Ø 7,5 (0.29) 40,5 0,1 (1.59 0.004) Ø 4,0 x 4,3 min. depth (0.16 dia x 0.17) for locating pin 70 (2.75) min. #10-24 UNC-2B optional.

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 13 Electrical Information

Block Diagram Voltage Input (M1) KBS*DG4V-3 KBS*DG4V-3 Wiring Connections must be made via the 7-pin plug mounted on the amplifier. See page 15 of this leaflet and Eaton’s Installation Wiring Practices for Vickers™ Electronic Prod- ucts, leaflet 2468. Recom- ±10V, or 4-20mA mended cable sizes are:

Power cables: For 24V supply 0,75 mm2 (18 AWG) up to Connected to valve body 20m (65 ft) 1,00 mm2 (16 AWG) up to 40m (130 ft) ▲ Pin C is used for a valve enable signal with electrical connections PH7 and PR7. Signal cables: 0,50 mm2 (20 AWG) Command Signals and Outputs, M1 Screen (shield): 7-pin plug Flow direction A suitable cable would have Pin D Pin E 7 cores, a separate screen Positive OV for the signal wires and an OV Negative P to A U - U = Positive overall screen. D E Negative OV Cable outside diameter 8,0– OV Positive P to B 10,5 mm (0.31–0.41inches) UD - UE = Negative See connection diagram on User Panel Outer Screen KB..PC7/PE7 valve next page. Power Supply +24V A 0V B C ■ Inner Screen Demand Signal 0V E Valve 4-20mA (M2), or ±10mA D must be (M3), or ±15mA (M4) Drain Wire G connected Spool 0V to ground Position via Monitor Input F subplate

Enclosure ▲ Connector 0V must be connected to ground shell

User Panel KB..PR7/PH7 valve Outer Screen Power Supply +24V A 0V B

Enable Signal 0V +8.5V C ■ to 36V Inner Screen Valve Demand must be Signal 0V E 4-20mA (M2), or ±10mA D connected (M3), or ±15mA (M4) Drain Wire to ground G via Spool 0V subplate Position Input F Monitor

Enclosure ▲ 0V must be Connector connected to ground shell

WARNING All power must be switched off before connecting/disconnecting any plugs.

14 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Electrical Information

Block Diagram Cur- rent Input (M2/M3/M4) KBS*DG4V-3 KBS*DG4V-3 Wiring

Connections must be made Power supply 0V via the 7-pin plug mounted on the amplifier. See page 15 of this leaflet and Eaton’s M Installation Wiring Practices for Vickers™ Electronic Prod- ucts, leaflet 2468. Recom- mended cable sizes are:

Power cables: Protective earth For 24V supply Connected to valve body 0,75 mm2 (18 AWG) up to 20m (65 ft) 2 1,00 mm (16 AWG) up to ▲ Pin C is used for a valve enable signal with electrical connections PH7 and PR7. 40m (130 ft) R1 shunt resistor 100R F1, F2 resettable fuse Signal cables: 0,50 mm2 (20 AWG) Command Signals and Outputs, M2 7-pin plug Screen (shield): Pin D Pin E Pin B Flow direction A suitable cable would have More than Current Power 7 cores, a separate screen 12 mA return ground P to A for the signal wires and an Less than Current Power overall screen. 12 mA return ground P to B Cable outside diameter User Panel Outer Screen KB..PC7/PE7 valve 8,0–10,5 mm (0.31–0.41 Command Signals and Outputs, M3 Power Supply +24V A inches) 0V B 7-pin plug C ■ Inner Screen See connection diagram on Demand Pin D Pin E Pin BSignal 0V Flow direction E Valve next page. 4-20mA (M2), or ±10mA D must be (M3), or ±15mA (M4) Drain Wire More than Current Power G connected Spool 0V to ground 0 mA return groundPosition P to A via Monitor Input F subplate Less than Current Power Enclosure ▲ 0 mA return ground P to B Connector 0V must be Note: Applicable only to Default Valve spool Closed loop position control mode. Refer connected to ground shell Field no. 18 of Model code. User Panel KB..PR7/PH7 valve Command Signals and Outputs, M4 Outer Screen Power Supply +24V A 7-pin plug 0V B

Pin D Pin E Pin BEnable Flow direction Signal 0V +8.5V C ■ More than Current Power to 36V Inner Screen Valve Demand must be 0 mA return groundSignal 0V P to A E 4-20mA (M2), or ±10mA D connected Less than Current Power(M3), or ±15mA (M4) Drain Wire to ground G via Spool 0V subplate 0 mA return groundPosition Input P to B F Monitor

Enclosure ▲ 0V must be Connector connected to ground shell

WARNING All power must be switched off before connecting/disconnecting any plugs.

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 15 Electrical Information

Wiring Connections Volt- User Panel Outer Screen KB..PC7/PE7 valve age Input (M1) Power ■ Spool position monitor volt- Supply +24V A age (pin F) will be referenced 0V B to the KB valve local ground. C ■ Inner Screen Demand D or E Signal 0V Valve ±10V must be Drain Wire connected G Spool 0V to ground Position via Monitor Input F subplate

Enclosure ▲ Connector 0V must be connected to ground shell

User Panel KB..PR7/PH7 valve Wiring Connections for M1 Outer Screen Valves with Enable Feature Power ▲ Note: In applications Supply +24V A where the valve must con- 0V B form to European RFI/EMC regulations, the outer screen Enable (shield) must be connected Signal 0V to the outer shell of the 7 +8.5V C ■ pin connector, and the valve to 36V Inner Screen body must be fastened to the Demand Valve D or E earth ground. Proper earth Signal 0V must be grounding practices must E or D ±10V Drain Wire connected be observed in this case, as G to ground any differences in command Spool via source and valve ground po- 0V Position Input F subplate tentials will result in a screen Monitor (shield) ground loop.

Enclosure ▲ 0V must be Connector connected to ground shell

16 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Electrical Information

Wiring Connections Cur- User Panel Outer Screen KB..PC7/PE7 valve rent Input (M2/M3/M4) Power ■ Spool position monitor volt- Supply +24V A age (pin F) will be referenced 0V B to the KB valve local ground. C ■ Inner Screen Demand Signal 0V E Valve 4-20mA (M2), or ±10mA D must be (M3), or ±15mA (M4) Drain Wire G connected Spool 0V to ground Position via Monitor Input F subplate

Enclosure ▲

Connector 0V must be connected to ground shell

User Panel KB..PR7/PH7 valve Wiring Connections for Outer Screen M2/M3/M4 Valves with En- Power able Feature Supply +24V A User Panel Outer Screen KB..PC7/PE7 valve ▲Power Note: In applications 0V B Supply +24V A where the0V valve must con- B C ■ form to EuropeanInner RFI/EMC Screen Enable Demand regulations,Signal 0V the outer screenE Valve Signal 0V 4-20mA (M2), or ±10mA D must be (M3), or ±15mA (M4) C Drain Wire +8.5V ■ (shield) must be connected G connected Spool 0V to ground Position via to 36V toMonitor the outer shell of the 7 Inner Screen Input F subplate Valve pin connector, and the valve Demand must be Enclosure ▲ 0V E body must be fastened to the Connector Signal 0V must be shell D connected connectedearth to ground ground. Proper earth 4-20mA (M2), or ±10mA (M3), or ±15mA (M4) Drain Wire to ground groundingUser Panel practices must KB..PR7/PH7 valve Outer Screen G via be observed in this case, as Spool Power 0V subplate anySupply differences+24V in commandA 0V B Position Input F Monitor sourceEnable and valve ground po- Signal 0V tentials+8.5V will result in a screenC ■ to 36V (shield) ground loop.Inner Screen Valve Demand must be Signal 0V E Enclosure ▲ 4-20mA (M2), or ±10mA D connected (M3), or ±15mA (M4) Drain Wire to ground G via Connector Spool 0V must be 0V subplate Position Input F Monitor connected to ground shell

Enclosure ▲ 0V must be Connector connected to ground shell

WARNING Electromagnetic Compatibility (EMC) It is Difficult environments could mean that necessary to ensure that the valve is wired extra screening may be necessary to up as above. For effective protection the avoid the interference. It is important to user electrical cabinet, the valve subplate connect the 0V lines as shown above. The or manifold and the cable screens should multi-core cable should have at least two be connected to efficient ground points. screens to separate the demand signal and The metal 7 pin connector part no. 934939 monitor output from the power lines. should be used for the integral amplifier. The enable line to pin C should be outside In all cases both valve and cable should the screen which contains the demand be kept as far away as possible from signal cables. any sources of electromagnetic radiation To ensure EMI protection use only metal such as cables carrying heavy current, shielded mating connectors. relays and certain kinds of portable radio transmitters, etc.

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 17 Software Information

KBS1DG4V KBS4DG4V • Analog commanded spool control. • KBS3DG4V capability on CANbus port at location at 3 and 4. • Analog command source configuration options. • IEC 61131-3 programmable device. • Monitor output signal configuration options. - Eaton ProFx® Control 2 IDE compatibility. • Enable input signal enable/disable option. - 384KB max application size (Flash). - 2KiB application accessible EEPROM. KBS2DG4V / KBS3DG4V - CANopen manager or slave configuration via CANbus port • KBS1DG4V capability. location 2. • Sensor port configuration options. Configurable position, - download and online debugging via CANbus Speed, Pressure, Force and SSI Sensors. (shared port with CANopen manager/slave). • CANopen DS408 compliant control modes (device - internal (function block) access to independent options vary per available hardware options). Level 3 slave device operations. - valve spool position control (VPOC/VSC). Note: All levels and models are compatible with the Eaton Pro-Fx® application and service tool software, version 2.2 or higher. - drive speed control (DSC). - drive force/pressure control (DFPC/DFP). - drive position control (DPC). - drive pressure/flow control (Eaton DPQ). • CANopen DS301 certified. - baudrate options: 50, 125, 250, 500, 800, 1000 kbps. - heartbeat and node guard configurable. - 8 mappable Rx PDOs (synchronous or asynchronous). - 8 mappable Tx PDOs (synchronous or asynchronous). - SYNC producer supported. - NMT self-start or commanded startup options. - emergency telegram and DR303-3 LED indications. - LSS protocol supported. • CANopen DSP306 compliant electronic data sheet (EDS). • Diagnostic configuration options.

18 EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 Application Data

Fluid Cleanliness Mounting Bolt Kits Proper fluid condition is essential for long and satisfactory life For KBS*DG4V-3 of hydraulic components and systems. Hydraulic fluid must BK02-156493M (metric) have the correct balance of cleanliness, materials and addi- tives for protection against wear of components, elevated BK590716 (inch) viscosity and inclusion of air. If not using Eaton recommended bolt kits, bolts used should be to ISO 898, 12.9 or better. The following recommendations are based on ISO cleanli- ness levels at 2 μm, 5 μm and 15 μm. For products in this Seal Kits catalog the recommended level is: KBS*DG4V-3.....6027549-001

17/15/12 Electrical Connectors KBS*DG4V Eaton products, as any components, will operate with appar- 7-pin (metal)...... 934939 ent satisfaction in fluids with higher cleanliness codes than those described. Other manufacturers will often recommend levels above those specified. Service Information Experience has shown, however, that life of any hydraulic The products from this range are preset at the factory for components is shortened in fluids with higher cleanliness optimum performance; disassembling critical items would de- codes than those listed above. These codes have been prov- stroy these settings. It is therefore recommended that should en to provide a long trouble-free service life for the products any mechanical or electronic repair be necessary they should shown, regardless of the manufacturer. be returned to the nearest Eaton repair center. The products will be refurbished as necessary and retested Hydraulic Fluids to specification before return. Field repair is restricted to the replacement of the seals. Materials and seals used in these valves are compatible with antiwear hydraulic oils, and non-alkyl-based phosphate esters. The extreme operating viscosity range is 500 to 13 cSt (2270 to 70 SUS) but the recommended running range is 54 to 13 cSt (245 to 70 SUS).

Installation The proportional valves in this catalog can be mounted in any attitude, but it may be necessary in certain demanding appli- cations, to ensure that the solenoids are kept full of hydraulic fluid. Good installation practice dictates that the tank port and any drain port are piped so as to keep the valves full of fluid once the system start-up has been completed.

EATON AxisPro™ Proportional Directional Valves with Feedback KBS*DG4V-3 E-VLPO-MC002-E September 2011 19 The Power of One Eaton

HANSEN™ GROMELLE™

There’s a certain energy at Eaton. It’s the power of integrating the competencies of some of the world’s most respected names to build a brand you can trust to meet every power management need. The energy created supports our commitment to powering business worldwide. As the world’s demand for high-efficiency hydraulic systems for mobile and stationary applications increase, Eaton is helping to solve these challenges more reliably, efficiently, and sustainably. Our goal is simple; to provide unique solutions across a wide range of markets that keep businesses on the leading edge of change. Visit Eaton.com/hydraulics/fusion. That’s the power of One Eaton.

Eaton Eaton Eaton Hydraulics Group USA Hydraulics Group Europe Hydraulics Group Asia Pacific 14615 Lone Oak Road Route de la Longeraie 7 Eaton Building Eden Prairie, MN 55344 1110 Morges 4th Floor, No. 3 LaneLane 280280 LinhongLinhong Rd.Rd. USA Switzerland Changning District Tel: 952-937-9800 Tel: +41 (0) 21 811 46004600 Shanghai 200335 Fax: 952-294-7722 Fax: +41 (0) 21 811 46014601 China www.eaton.com/hydraulics Tel: (+86 21) 5200 00990099 Fax: (+86 21) 5200 04000400

© 2011 Eaton Corporation © 2011 Eaton Corporation All Rights Reserved All rights reserved Printed in USA Printed in USA Document No. E-VLPO-MC002-E Document No. X-XXXX-XXXXX-X September 2011 May 2011

Fusion Ad Back Cover Only.indd 2 5/12/11 5:58 PM