Harvard Biolabs Stockroom

Total Page:16

File Type:pdf, Size:1020Kb

Harvard Biolabs Stockroom THE HARVARD BIOLABS STOCKROOM Biolabs Basement—B060 Biolabs Bldg ‐ 16 Divinity Ave Phone: 617.495.2385 Monday ‐ Friday: 8:00 am ‐ 4:50 pm* *Closed daily 12:00 ‐ 1:00 pm The Harvard Biolabs Stockroom The Harvard BioLabs Stockroom Biolabs Basement—B060 The current Harvard Biolabs Stockroom was created in collaboraon with Operaons and Facilies at FAS and VWR Internaonal to provide researchers with quick, convenient access to the most frequently ordered laboratory supplies, enzymes and biologicals. Products are sourced from VWR core suppliers, as well as other popular manufacturers such as Qiagen, NEB, Falcon and Corning. Researchers using Harvard funds for payment are eligible to purchase from the Stockroom. To ensure accurate billing, shoppers should be prepared to provide idenficaon and up‐to‐date grant informaon at the request of Stockroom personnel. All non‐stockroom orders should be placed on‐line via HCOM or by calling VWR at 866‐229‐9967 “Call Ahead” ‐The Stockroom offers walk‐ in service. However, you may want to “call ahead” to 617‐495‐2385 so the VWR associate can ensure availability of the products requested. VWR will provide a receipt detailing all items on the order. Only products in stock will be included. Back orders will not be accepted. Backordered products should be ordered as a new transacon when stock arrives. Check with VWR at 866‐229‐9967 or HCOM for availability. VWR manages the 190 and 200 proof tax free ethanol program for Harvard University. Ethanol can be purchased by the gallon(s) or pint in the Stockroom. The on‐campus stockroom is intended to meet immediate needs for less‐ than‐case quanty products; for larger orders it is recommended purchases be made on line via HCOM, by calling 866‐229‐9967 or by e‐mailing [email protected]. Business Hours: VWR CONTACTS 8 AM – 4:50 PM Monday—Friday, EST Closed between 12:00 pm – 1 pm VWR Stockroom Onsite Coordinators Closed Saturday and Sunday Day to day operaons of the stockroom: Returns: Joe Pelrine Jose Derito Applies to all products received from VWR (not [email protected] [email protected] limited to Stockroom purchases) Product may be returned to the Stockroom in original, unused condion with a copy of the Purchase Order or Jerrold Bornstein receipt VWR’s Harvard Account Manager Or, call 617‐495‐2385 for return authorizaon Contact for specific department needs Product pick up from your lab within 2 days or overview of VWR services No restocking charges [email protected] Frozen biological products are non‐returnable Phone: 617.495.2385 · Hours: M-F: 8:00 am - 4:50 pm Page 2 The Harvard Biolabs Stockroom Lighter, Circulators, Hot Plates, Vortex, Vaccum Pump, Filter Paper LIGHTER, FLINT TIPS, BUNSEN BURNER VWR Part Descripon Unit of Manufacturer Manufacturer Part Number Measure Number 18385‐220 Laboratory Gas Lighter EA VWR 18385‐220 18385‐223 Replacement Flint Tips (lasts 2000 ignions) PK (5) VWR 18385‐223 89038‐530 Bunsen Burner—Natural Gas, 800–1200 BTU EA VWR 89038‐530 CIRCULATORS, HOT PLATES, VORTEX, VACUUM PUMP VWR Part Descripon Unit of Manufactu Manufacturer Part Number Measure rer Number 71002‐500 Algaecide Bole 8oz EA Polysci 004‐300040 10153‐690 Magnec Srrer, Low profile, 15‐1500 RPM 100V EA VWR MS‐01FU‐VWR 10153‐688 Mini Vortex Mixer, 3000 RPM, Touch and Go, 100V EA VWR VM‐03U‐VWR FILTER PAPER, STANDARD GRADE VWR Part Number Descripon Unit of Measure Manufacturer Manufacturer Part Number 21426‐402 Filter Paper # 8.5 cm EA (100) Whatman 1001‐085 28450‐026 Filter Paper #1 42.5 mm PK (100) Whatman 1001‐042 28450‐048 Filter Paper #1 5.5 cm PK (100) Whatman 1001‐055 28450‐070 Filter Paper #1 7 cm PK (100) Whatman 1001‐070 28450‐081 Filter Paper #1 9 cm PK (100) Whatman 1001‐090 28450‐106 Filter Paper #1 11 cm PK (100) Whatman 1001‐110 28450‐128 Filter Paper #1 12.5 cm PK (100) Whatman 1001‐125 28450‐150 Filter Paper #1 15 cm PK (100) Whatman 1001‐150 28450‐160 Filter Paper #1 18.5 cm PK (100) Whatman 1001‐185 Phone: 617.495.2385 · Hours: M-F: 8:00 am - 4:50 pm Page 3 The Harvard Biolabs Stockroom GLOVES‐Liners, Rubber, Autoclave and Latex GLOVE LINERS Knit, Nylon, Full Finger VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number SC94000‐608 Small EA VWR GLFF‐S SC94000‐610 Medium EA VWR GLFF‐M SC94000‐612 Large EA VWR GLFF‐L SC94000‐614 X‐Large EA VWR GLFF‐XL GLOVES—RUBBER and AUTOCLAVE Rubber gloves are hardened against chemicals and abrasion. So coon flock‐lined. 13” long. 18 mil thick. VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number SC32890‐020 Tan, Rubber, Size 7 1 Pair Ansell Healthcare 115601 SC32890‐022 Tan, Rubber, Size 8 1 Pair Ansell Healthcare 115603 SC32890‐024 Tan, Rubber, Size 9 1 Pair Ansell Healthcare 115605 SC32890‐026 Tan, Rubber, Size 10 1 Pair Ansell Healthcare 115607 GLOVES—AUTOCLAVE VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number 32885‐826 Heat resistant up to 232°C, 18” long 1 Pair Bel‐Art H13201‐0001 GLOVES—LATEX VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number 32916‐530 Evoluon One, X‐Small PK (100) Microflex EV‐2050‐XS 32916‐532 Evoluon One, Small PK (100) Microflex EV‐2050‐S 32916‐534 Evoluon One, Medium PK (100) Microflex EV‐2050‐M 32916‐536 Evoluon One, Large PK (100) Microflex EV‐2050‐L 32916‐538 Evoluon One, X‐Large PK (100) Microflex EV‐2050‐XL 414004‐429 VWR Powder Free, Small PK (100) VWR 414004‐429 414004‐430 VWR Powder Free, Medium PK (100) VWR 414004‐430 414004‐431 VWR Powder Free, Large PK (100) VWR 414004‐431 414004‐432 VWR Powder Free, X‐Large PK (90) VWR 414004‐432 Phone: 617.495.2385 · Hours: M-F: 8:00 am - 4:50 pm Page 4 The Harvard Biolabs Stockroom GLOVES—Nitrile, Lab Coats GLOVES—NITRILE, Powder Free VWR Part Number Descripon Unit of Measure Manufacturer Manufacturer Part Number 89038‐267 Examinaon, So, X‐Small PK (100) VWR 10772‐130 89038‐268 Examinaon, So, Small PK (100) VWR 10772‐113 89038‐270 Examinaon, So, Medium PK (100) VWR 89038‐270 89038‐272 Examinaon, So, Large PK (100) VWR 89038‐272 89038‐274 Examinaon, So, X‐Large PK (100) VWR 89038‐274 89140‐816 Sterling, 9.5” length, X‐Small PK (200) Kimberly‐Clark 50705 89140‐818 Sterling, 9.5” length, Small PK (200) Kimberly‐Clark 50706 89140‐820 Sterling, 9.5” length, Medium PK (200) Kimberly‐Clark 50707 89140‐822 Sterling, 9.5” length, Large PK (200) Kimberly‐Clark 50708 40101‐440 Microgrip, Purple, X‐Small PK (100) VWR 56956 40101‐344 Microgrip, Purple, Small PK (100) VWR 56952 40101‐346 Microgrip, Purple, Medium PK (100) VWR 40101‐346 40101‐348 Microgrip, Purple, Large PK (100) VWR 56954 40101‐350 Microgrip, Purple, X‐Large PK (100) VWR 56955 32916‐682 FreeForm SE, Blue, Small PK (100) Microflex FFS‐700‐S 32916‐684 FreeForm SE, Blue, Medium PK (100) Microflex FFS‐700‐M 32916‐686 FreeForm SE, Blue, Large PK (100) Microflex FFS‐700‐L 32916‐688 FreeForm SE, Blue, X‐Large PK (100) Microflex FFS‐700‐XL LAB COAT—MEN’S, KNEE LENGTH, 3 PATCH REINFORCED POCKETS, COTTON TWILL VWR Part Descripon Unit of Measure Manufacturer Manufacturer Number Part Number 10834‐263 Size 36 EA Superior Uniform 481‐36 10834‐264 Size 38 EA Superior Uniform 481‐38 10834‐265 Size 40 EA Superior Uniform 481‐40 10834‐266 Size 42 EA Superior Uniform 481‐42 10834‐267 Size 44 EA Superior Uniform 481‐44 LAB COAT—WOMEN’S, 2 PATCH POCKETS, ONE BREAST POCKET, 5 BUTTONS VWR Part Descripon Unit of Measure Manufacturer Manufacturer Number Part Number 17788‐132 Women’s, White, Size 4 EA Encompass 47401‐W04 Phone: 617.495.2385 · Hours: M-F: 8:00 am - 4:50 pm Page 5 The Harvard Biolabs Stockroom SAFETY—Eye, Face, First Aid, Respirator, Glass Box Hand Care EYE and FACE PROTECTION VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number 47746‐328 Lexa Splash GoggleGear Goggles, Clear, Large EA 3M 16645‐00000‐10 SC47751‐864 Lexa Fighter Protecve Eyewear, Clear EA 3M 15152‐00000100 15001‐570 EYEWEAR PROTEC UVEXTREME CLEAR EA Honeywell S3200X 26902‐670 EYEWEAR SPITFIRE UVEXTREME BLK EA Honeywell S1800X 33000‐506 SPECTACLES UVEX ASTRO OTG BLK EA Honeywell S2500 33002‐546 GOGGLE FLEX SEAL UVEX EA Honeywell S3400X 33002‐702 EYEWEAR SAFETY UVEXTREME CLEAR EA Honeywell S1600X 89009‐114 EYEWEAR PRCTN SAFETY UVEXTRA AF CLEAR EA Honeywell S4200X 89095‐493 UVEX AMBIENT OTG ULTDURA EYEWR EA Honeywell S3160 33001‐230 CUDAS BLK FRAME/CLR LENS ADJST EA KC 14464 SC26902‐502 VWR HOOD IRRADIATED CLR‐WT UNIV EA (125) VWR S501 SAFETY—Ibuprofen, Alcohol Wipes, Broken Glass Box, Respirator VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number 89106‐852 CEDAPRIN IBUPRFEN 200MG EA (50) Honeywell 166180 89186‐140 ALCOHOL WIPES 70% PK (200) Honeywell 156818X 15431‐475 STAT STRIPS SHR 3/4X3IN PK100 PK (100) DERMA 15200 SC56617‐801 VWR BROKEN GLASS DISPL BOX FLR EA VWR 246531001 89201‐508 VWR N95 RESPIRATOR PK (20) VWR 9500‐N95 HAND CARE VWR Part Number Descripon Unit of Measure Manufactu Manufacturer Part rer Number 56614‐410 VWR® Handcream, Soguard 3oz EA (89mL) VWR 12003‐12‐601 56614‐414 VWR® Handcream, Soguard 16oz EA (16oz) VWR 11016‐06‐601 56614‐420 VWR® Soap, Soicide 32oz EA (32oz) VWR 21032‐06‐601 56700‐116 VWR® Alcoscrub Gel 16oz EA (16oz) VWR 42016‐12‐601 56700‐124 VWR® Soap, Soicide 16oz, Pump bole EA (16oz) VWR 21016‐06‐601 56700‐144 VWR® Soap, Soicide , 32 oz, Hand soap EA (32oz) VWR 25032‐12‐601 Phone: 617.495.2385 · Hours: M-F: 8:00 am - 4:50 pm Page 6 The Harvard Biolabs Stockroom Baeries, Janitorial, Wire, Surge Strip, Thermometer BATTERIES VWR Part Number Descripon Unit of Manufacturer Manufacturer Part Measure Number 89215‐862 RV3033571ZM
Recommended publications
  • Npgrj Nprot 406 2517..2526
    PROTOCOL Identification and analysis of essential Aspergillus nidulans genes using the heterokaryon rescue technique Aysha H Osmani, Berl R Oakley & Stephen A Osmani Department of Molecular Genetics, The Ohio State University, Columbus, Ohio 43210, USA. Correspondence should be addressed to S.A.O. ([email protected]) Published online 29 December 2006; corrected online 25 January 2007 (details online); doi:10.1038/nprot.2006.406 s In the heterokaryon rescue technique, gene deletions are carried out using the pyrG nutritional marker to replace the coding region of target genes via homologous recombination in Aspergillus nidulans. If an essential gene is deleted, the null allele is maintained in spontaneously generated heterokaryons that consist of two genetically distinct types of nuclei. One nuclear type has the essential gene deleted but has a functional pyrG allele (pyrG+). The other has the wild-type allele of the essential gene but lacks a functional pyrG allele (pyrG–). Thus, a simple growth test applied to the uninucleate asexual spores formed from primary transformants can natureprotocol / m identify deletions of genes that are non-essential from those that are essential and can only be propagated by heterokaryon rescue. o c . The growth tests also enable the phenotype of the null allele to be defined. Diagnostic PCR can be used to confirm deletions at the e r molecular level. This technique is suitable for large-scale gene-deletion programs and can be completed within 3 weeks. u t a n . w w INTRODUCTION w / / : One of the most fundamental pieces of information regarding the non-essential gene is deleted, the resulting strains are able to grow p t t function of any gene is whether the gene is essential or not.
    [Show full text]
  • Bacterial Survival in Microscopic Surface Wetness Maor Grinberg†, Tomer Orevi†, Shifra Steinberg, Nadav Kashtan*
    RESEARCH ARTICLE Bacterial survival in microscopic surface wetness Maor Grinberg†, Tomer Orevi†, Shifra Steinberg, Nadav Kashtan* Department of Plant Pathology and Microbiology, Robert H. Smith Faculty of Agriculture, Food, and Environment, Hebrew University, Rehovot, Israel Abstract Plant leaves constitute a huge microbial habitat of global importance. How microorganisms survive the dry daytime on leaves and avoid desiccation is not well understood. There is evidence that microscopic surface wetness in the form of thin films and micrometer-sized droplets, invisible to the naked eye, persists on leaves during daytime due to deliquescence – the absorption of water until dissolution – of hygroscopic aerosols. Here, we study how such microscopic wetness affects cell survival. We show that, on surfaces drying under moderate humidity, stable microdroplets form around bacterial aggregates due to capillary pinning and deliquescence. Notably, droplet-size increases with aggregate-size, and cell survival is higher the larger the droplet. This phenomenon was observed for 13 bacterial species, two of which – Pseudomonas fluorescens and P. putida – were studied in depth. Microdroplet formation around aggregates is likely key to bacterial survival in a variety of unsaturated microbial habitats, including leaf surfaces. DOI: https://doi.org/10.7554/eLife.48508.001 Introduction *For correspondence: The phyllosphere – the aerial parts of plants – is a vast microbial habitat that is home to diverse [email protected] microbial communities (Lindow and Brandl, 2003; Lindow and Leveau, 2002; Vorholt, 2012; Vacher et al., 2016; Leveau, 2015; Bringel and CouA˜ ce, 2015). These communities, dominated by †These authors contributed bacteria, play a major role in the function and health of their host plant, and take part in global bio- equally to this work geochemical cycles.
    [Show full text]
  • WL Brewery Contaminates Instructions Highres
    WHITE LABS ® TEST KITS BREWERY CONTAMINANTS DETECTION SAMPLE KIT PLEASE READ ALL PROCEDURAL INSTRUCTIONS THOROUGHLY BEFORE STARTING THE TEST. YOUR KIT INCLUDES: • (5) 15mL sterile culture tubes with rack • (10) 15mL sterile culture tubes with 9mL sterile water (for dilutions) • (1) 2oz 70% isopropanol solution • (1) 90mL Hsu’s Lactobacillus and Pediococcus (HLP) Media (keep refrigerated) • (6) Lin’s Cupric Sulfate Media (LCSM) plates (please keep plates stored media side up in refrigerator until 1 hour before use) • (6) Schwartz Differential Media (SDA) plates (please keep plates stored media side up in refrigerator until 1 hour before use) • (10) sterile cell spreaders • (2) 50mL vials sterile, distilled water • (2) pair laboratory gloves • (16) sterile transfer pipettes with graduations • Instructions OTHER SUGGESTED MATERIALS: (MUST BE PURCHASED SEPARATELY) • Alcohol lamp • Micropipettor and tips BACKGROUND: This kit provides three types of selective medias for the detection of aerobic bacteria (SDA medium), anaerobic bacteria (HLP medium), and wild yeast (LCSM medium). White round colonies will be present in HLP is Lactobacillus or Pediococcus is present. Teal or blue bacterial colonies will be present on SDA if bacterial contamination is present. LCSM provides the best means for a brewery to test for the presence of Non-Saccharomyces wild yeast. This medium inhibits, or markedly restricts, growth of brewery culture yeast while permitting growth of a variety of wild yeast using cupric sulfate. Some specific brewing yeast strains (typically Hefeweizen, Belgian strains) of brewer’s yeast show weak growth on LWYM. TAKING THE SAMPLE: How to take a sterile sample from a heat exchanger: • Collect wort from a valve after heat exchanger in sterile 50 ml tube (provided) How to take a fermentor/brite tank sample: • Use cotton swab to swab any sediment in the zwiggle/stop cock.
    [Show full text]
  • Polypropylene
    CELLTREAT® Scientific Products is dedicated to manufacturing unique, high-quality laboratory plastic consumables at significant savings compared to alternative brands. User-friendly features are incorporated into the CELLTREAT product line to improve research efficiency with easier handling and outstanding performance. We provide high levels of personalized service and regularly challenge everything we do to improve and exceed customer expectations. Experience the CELLTREAT difference. CELLTREAT Table of Contents Accessories (Bag Cutter & Timer) .............................. 9 Flasks, Erlenmeyer - PETG ......................................... 43 Beakers ...................................................................... 9 Flasks, Erlenmeyer & Fernbach - Polycarbonate ....... 42 Bio-reaction Tubes .................................................... 19 Flasks, Non-Treated Suspension Culture ................... 29 Vent Control Labels .......................................... 19 Flasks, Tissue Culture Treated ................................... 28 Bottles, Centrifuge .................................................. 21 Flasks, Caps Only ....................................................... 29 Bottles, Media ........................................................... 44 Glass Fiber Filter Disks .............................................. 45 Bottles, Roller ........................................................... 41 Lab Grab Multi-Use Extension Grabber .................... 37 Bottles, Solution .....................................................
    [Show full text]
  • CELLTREAT Cell and Tissue Culture Labware
    Table of Contents Table of Contents Tissue and Suspension Culture Flasks .................................................. 1 Flask Caps and Cell Strainers ............................................................... 2 Tissue Culture Dishes ............................................................................. 3 Multiwell Plates, Treated and Non-Treated .....................................4-5 Chambered Cell Culture Slides ........................................................... 6 Bio-reaction Tubes .............................................................................6-7 Fernbach and Erlenmeyer Culture Flasks ........................................... 8 Roller Bottles and Square Media Bottles ............................................ 9 Cell Scrapers and Lifters ..................................................................... 10 Vacuum Filter Systems ........................................................................ 11 Solution Bottles .................................................................................... 11 Filter Adapters & Centrifuge Tube Filters .......................................... 12 Syringe Filters ........................................................................................ 13 Petri-Dishes ........................................................................................... 14 Inoculating Loops, Needles and Cell Spreaders ............................. 15 Pipets and Reagent Reservoirs .....................................................16-21 Centrifuge Tubes
    [Show full text]
  • Detection of Bacteriophage Infection Using Absorbance
    DETECTION OF BACTERIOPHAGE INFECTION USING ABSORBANCE, BIOLUMINESCENCE, AND FLUORESCENCE TESTS Thesis Submitted to The School of Engineering of the UNIVERSITY OF DAYTON In Partial Fulfillment of the Requirements for The Degree Master of Science in Civil Engineering By Lindsey Marie Staley UNIVERSITY OF DAYTON Dayton, Ohio May, 2011 DETECTION OF BACTERIOPHAGE INFECTION USING ABSORBANCE, BIOLUMINESCENCE, AND FLUORESCENCE TESTS Name: Staley, Lindsey Marie APPROVED BY: ___________________________ __________________________ Denise Taylor, Ph. D., P.E. Kenya Crosson, Ph.D. Advisory Committee Chairman Committee Member Assistant Professor Assistant Professor Department of Civil and Department of Civil and Environmental Engineering and Environmental Engineering and Engineering Mechanics Engineering Mechanics ____________________________ Deogratias Eustace, Ph.D. Committee Member Assistant Professor Department of Civil and Environmental Engineering and Engineering Mechanics ___________________________ __________________________ John G. Weber, Ph.D. Tony E. Saliba, Ph.D. Associate Dean Wilke Distinguished Professor & School of Engineering Dean School of Engineering ii ABSTRACT DETECTION OF BACTERIOPHAGE INFECTION USING ABSORBANCE, BIOLUMINESCENCE, AND FLUORESCENCE TESTS Name: Staley, Lindsey Marie University of Dayton Advisor: Dr. Denise Taylor The activated sludge treatment process is a common method employed to treat wastewater. Normal operation of this process results in a floc-forming bacterial mixture, which settles rapidly. However, filamentous bacteria can cause sludge bulking, which interferes with the compaction and settling of flocs. A common method to control sludge bulking is adding a chemical such as chlorine to the activated sludge basin, which kills not only the problematic bacteria, but also the essential floc-forming bacteria. Bacteriophages (phages) are viruses that only infect bacteria. It is hypothesized that phages of filamentous bacteria can be added to the activated sludge basin to control sludge bulking, rather than a chemical.
    [Show full text]
  • Mb352 General Microbiology Laboratory 2021
    MB352 GENERAL MICROBIOLOGY LABORATORY 2021 Alice Lee North Carolina State University North Carolina State University MB352 General Microbiology Laboratory 2021 (Lee) This text is disseminated via the Open Education Resource (OER) LibreTexts Project (https://LibreTexts.org) and like the hundreds of other texts available within this powerful platform, it freely available for reading, printing and "consuming." Most, but not all, pages in the library have licenses that may allow individuals to make changes, save, and print this book. Carefully consult the applicable license(s) before pursuing such effects. Instructors can adopt existing LibreTexts texts or Remix them to quickly build course-specific resources to meet the needs of their students. Unlike traditional textbooks, LibreTexts’ web based origins allow powerful integration of advanced features and new technologies to support learning. The LibreTexts mission is to unite students, faculty and scholars in a cooperative effort to develop an easy-to-use online platform for the construction, customization, and dissemination of OER content to reduce the burdens of unreasonable textbook costs to our students and society. The LibreTexts project is a multi-institutional collaborative venture to develop the next generation of open-access texts to improve postsecondary education at all levels of higher learning by developing an Open Access Resource environment. The project currently consists of 13 independently operating and interconnected libraries that are constantly being optimized by students, faculty, and outside experts to supplant conventional paper-based books. These free textbook alternatives are organized within a central environment that is both vertically (from advance to basic level) and horizontally (across different fields) integrated.
    [Show full text]
  • A Gene Discovery Lab Manual for Undergraduates: Searching For
    A Gene Discovery Lab Manual For Undergraduates: Searching For Genes Required To Make A Seed Honors Collegium 70A Laboratory Spring 2006 By Anhthu Q. Bui Brandon Le Bob Goldberg Department of Molecular, Cell, & Developmental Biology UCLA Sponsored by HHMI HC70AL Protocols Spring 2006 Professor Bob Goldberg Table of Contents Experiments Experiment 1 - Introduction To Molecular Biology Techniques 1.1 – 1.27 Experiment 2 - Screening SALK T-DNA Mutagenesis Lines (Gene ONE) 2.1 – 2.34 Experiment 3 - RNA Isolation and RT-PCR Analysis (Gene ONE) 3.1 – 3.26 Experiment 4 - Amplification and Cloning a Gene Promoter Region (Gene ONE) 4.1 – 4.26 Experiment 5 - Observation and Characterization of Known and Unknown Mutants 5.1 – 5.4 Experiment 6 - Screening SALK T-DNA Mutagenesis Lines (Gene TWO) 6.1 – 6.20 Experiment 7 - RNA Isolation and RT-PCR Analysis (Gene TWO) 7.1 – 7.6 Experiment 8 - Amplification and Cloning a Gene Promoter Region (Gene TWO) 8.1 – 8.26 Experiment 9 - Observation and Characterization of Known and Unknown Mutants 9.1 – 9.6 Appendixes: Appendix 1A - Preparation of Agarose Gel A1A.1 – A1A.2 Appendix 1B - Nanodrop Spectrophotometer A1B.1 – A1B.5 Appendix 1C - 1-kb DNA Ladder A1C.1 – A1C.2 Appendix 1D - iProof High Fidelity DNA Polymerase A1D.1 – A1D.3 Appendix 1E - pCR-Blunt II-TOPO Cloning Instruction A1E.1 – A1E.12 Appendix 1F - QIAprep Miniprep Handbook A1F.1 – A1F.25 Appendix 2 - Bioinformatics Presentations Parts I and II A2.1 – A2.16 Table of Contents EXPERIMENT 1 – INTRODUCTION TO GENERAL MOLECULAR BIOLOGY TECHNIQUES STRATEGY I.
    [Show full text]
  • UW Igem Lab Training Exercise
    iGEM Training UW iGEM Lab Training Exercise The overall goal of the lab exercise is to transform E. coli cells previously unable to express GFP (green fluorescent protein), to now express GFP. GFP expression is visible when the cells are viewed under UV light. This is done by turning on a gene, which is achieved by positioning a promoter in front of the sequence and assembling it into another vector. This is done all in one step. (Drawn on board) To separate out the plasmid DNA (which acts as the vector to contain our gene of interest) we use the cells inherent chemical nature and manipulate it to differentiate the cell components. Centrifuging is a big component of the separation of cell components by spinning at high speeds. It separates components of different sized in a mixture and is therefore used to separate out different cell components. Important Notes on Centrifugation… (When centrifuging make sure that tubes are placed across each other so that the centrifuge is balanced. If you have an odd number of tubes, a microfuge tube filled with the equivalent amount of water can be used as a “dummy tube”. Orient the tube with the hinge facing up so you can anticipate where the pellet is going to form, as it may be difficult to see a pellet in some miniprep procedures) MOST IMPORTANTLY!: This is a sequential process and the samples that you are working with will be carried on to the next day. If at any point you are confused/unsure ASK! CONTENTS DAY 1: Pipette Basics, Plasmid Miniprep and Restriction Digest .............................................................................2
    [Show full text]
  • Gentix Plasticwares Vol II
    1 CAT# Product Description Price( ) CAT# Product Description Price( ) Contents 02-03 Eco-Prep 04 05-29 PLASTICWARE (SPL) 30-57 58 59-61 62-63 64-67 BENCH TOP INSTRUMENTS 68-79 80-81 LAB SAFETY & HYGEINE 82 83 GENETIX BRAND GLOVES 84-85 2015-16 86-87 E-mail : [email protected] Call +91-11-45027000 ~ Fax: +91-11-25419631 2 CAT# Product Description Price( ) CAT# Product Description Price( ) Nucleopore brings you the best tools available for purification of nucleic acids (DNA and RNA) and NP-36172 Rapid Prep 96 Plasmid Kit (4 Plates) 54,180 proteins. These kits are user-friendly, reliable, effi- NP-36174 Rapid Prep 96 Plasmid Kit (24 Plates) 273,420 cient and versatile. NP-37192 SureSpin® Plasmid 96 Kit, 1 x 96 Preps POR NP-37193 SureSpin® Plasmid 96 Kit, 4 x 96 Preps POR NP-79182 DNA SureSpin 96 Plant Kit, 4 x 96 Preps POR NP-79183 DNA SureSpin 96 Plant Kit, 24 x 96 Preps POR NP-84182 RNA SureSpin 96 Kit, 2 x 96 Preps POR NP-84183 RNA SureSpin 96 Kit, 4 x 96 Preps POR Genomic DNA Purification Tissue NP-61305 DNASure® Tissue Mini Kit (50) 9,324 NP-61307 DNASure® Tissue Mini Kit (250) 39,690 Benefits: NP-66405 DNASure® PET Mini Kit (50) 10,710 l Reliable Analysis NP-1003D Nucleopore® MicroPET DNA Mini Kit (50) 27,996 l Reproducible Results l Increased Power to Compete Blood DNA Extraction Kits (Plasmid & Genomic) NP-61105 DNASure® Blood Mini Kit (50) 8,820 Plasmid DNA Purification NP-61107 DNASure® Blood Mini Kit (250) 37,800 NP-37105 SureSpin® Plasmid Mini Kit (50) 5,230 NP-61184 DNASure® Blood Midi Kit (20) 12,474 NP-37107 SureSpin®
    [Show full text]
  • Introduction to Microbiology Biosci 221 Laboratory Manual
    Introduction to Microbiology Biosci 221 Laboratory Manual Griffith Observatory. K. C. Burke Created by Kelly C. Burke College of the Canyons Version 1 - Spring 2017 2017, Kelly C. Burke. Licensed under the CC-BY 4.0 license College of the Canyons – BIOSCI 221 Kelly C. Burke Attributions: Created By: Kelly C. Burke Important Information about This Book Edits Made By: Natalie Miller & Frederick Bobola This book was made possible by funding through College of the Canyons and the support of Chancellor Dianne G. Van Hook Special thanks to: The Distance Learning Team Unless otherwise stated, all unlabeled images in this book are under Kelly C. Burke CC BY-NC SA 4.0 2 | Introduction College of the Canyons – BIOSCI 221 Kelly C. Burke Table of Contents Safety ............................................................................................................................................ 4 The Metric System, Measurement, and Lab Equipment Review ............................... 13 Microscopy ................................................................................................................................ 25 Environmental Sampling ........................................................................................................ 38 Survey of Eukaryotic Microorganisms: The Protists Algae ............................................ 45 Parasitic Helminths ................................................................................................................... 52 Fungi ...........................................................................................................................................
    [Show full text]
  • A Simple and Efficient Method for Preparing Cell Slides and Staining Without Using Cytocentrifuge and Cytoclips
    Hindawi Publishing Corporation International Journal of Cell Biology Volume 2015, Article ID 813216, 4 pages http://dx.doi.org/10.1155/2015/813216 Research Article A Simple and Efficient Method for Preparing Cell Slides and Staining without Using Cytocentrifuge and Cytoclips Xiaotang Hu,1 Verronika Laguerre,2 Daniel Packert,2 Alice Nakasone,1 and Lynn Moscinski3 1 Department of Biology, College of Arts & Sciences, Barry University, Miami Shores, FL, USA 2Biomedical Sciences Program and Clinical Biology, College of Nursing and Health Sciences, Barry University, Miami Shores, FL, USA 3Division of Hematopathology and Laboratory Medicine, Department of Oncologic Sciences, University of South Florida and H. Lee Moffitt Cancer Center, Tampa, FL, USA Correspondence should be addressed to Xiaotang Hu; [email protected] Received 14 September 2015; Accepted 4 November 2015 Academic Editor: Rony Seger Copyright © 2015 Xiaotang Hu et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Cell staining is a necessary and useful technique for visualizing cell morphology and structure under a microscope. This technique has been used in many areas such as cytology, hematology, oncology, histology, virology, serology, microbiology, cell biology, and immunochemistry. One of the key pieces of equipment for preparing a slide for cell staining is cytology centrifuge (cytocentrifuge) such as cytospin. However, many small labs do not have this expensive equipment and its accessory, cytoclips (also expensive relatively), which makes them difficult to study cell cytology. Here we present an alternative method for preparing a slide and cell staining in the absence of a cytocentrifuge (and cytoclips).
    [Show full text]