FLOW RATE INDICATOR WITH VERY LARGE DIGITS Features Signal input • Displays instantaneous flow rate and Flow measuring unit. • Reed-switch. • Very large 26mm (1") digits. • NAMUR. • Piegraph indication: ten segments. • NPN/PNP pulse. • Selectable on-screen engineering units; • Sine wave (coil). volumetric or mass. • Active pulse signals. • Ability to process all types of flowmeter • (0)4 - 20mA. signals. • 0 - 10V DC. • Auto backup of all settings. • Operational temperature -40°C up to +80°C Applications (-40°F up to 176°F). • Flow measurement where a local flow rate • Rugged aluminum field mount enclosure indication is required without IP67/NEMA4X. re-transmission or totalizer functionality. DATASHEET INDICATOR RATE F010 - FLOW • Intrinsically Safe - ATEX, IECEx, FM and CSA Alternative advanced models: F012 - F013 - approval for gas and dust applications. F014 - F016 or even more advanced F110 • Explosion/flame proof II 2 GD EEx d IIB T5. and higher. • Easy configuration with clear alphanumerical display. • LED backlight option. • Loop or battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 3.2 / 8.2 / 12 / 24V DC. 1 General information Signal input Introduction The F010 accepts most pulse and analog input The F010 is a local indicator to display the signals for volumetric flow or mass flow actual flow rate. The measuring and time unit measurement. The input signal type can be to be displayed are simply selected through an selected by the user in the configuration menu alfa-numerical configuration menu. No adhesive without having to adjust any sensitive labels have to be put on the outside of the mechanical dip-switches, jumpers or trimmers. enclosure: a weather proof and user friendly The analog input version is even available as solution! 4 - 20mA input loop powered display. The configuration of K-factors or Span and number of decimals is done through software Power supply functions, without any sensitive dip-switches or Several power supply options are available to trimmers. A wide selection of options further power the F010 and sensor. Most popular is our enhance this models capabilities, including battery powered version with a long life lithium Intrinsic Safety for hazardous area applications. battery which will last up to five years. For analog sensors, a 4 - 20mA loop powered Display version is available as well. A real sensor supply The display has very large 26mm (1”) digits is offered with the 24V AC/DC or 115 - 230V AC which can be set to show the flow rate and the power supply option. measuring and time units. As the F010 has been designed for field mounted applications, a Hazardous area smart display update function has been For hazardous area applications, this model incorporated. Related to the lower has been ATEX, IECEx, FM and CSA certified temperatures, the update frequency of the LCD Intrinsically Safe for gas and dust is tuned automatically to achieve a readable applications, with an allowed operational display even at -40°C / -40°F. temperature of -40°C to +70°C (-40°F to +158°F). A flame proof enclosure with ATEX Backlight certification offers the rating II 2 GD EEx For those applications where readability during d IIB T5. day and night is an issue, a bi-color backlight is available. The background color can be set to Enclosures green or amber and the intensity can be adjusted Various types of enclosures can be selected, all from the keyboard. The display is a transflective ATEX, IECEx, FM and CSA approved. As type, which means that a high contrast reading standard the F010 is supplied in an GRP panel is guaranteed in full sunlight as well as during mount enclosure, which can be converted to an the night. This backlight option is also available IP67 / NEMA 4X GRP field mount enclosure by Intrinsically Safe. the addition of a back case. Most popular is our aluminum field mount enclosure with IP67 / Configuration NEMA 4X rating. Both European or U.S. cable All configuration settings are accessed via a gland entry threads are available. simple operator menu which can be pass-code protected. Each setting is clearly indicated with Overview application F010 an alphanumerical description, which avoids confusing abbreviations and baffling codes. Once familiar with one F-series product, you will be able to program all models in the series without a manual. All settings are safely stored Flowmeter in EEPROM memory in the event of sudden input power failure. 2 F010 Dimensions enclosures Terminal connections power supply Aluminum & GRP panel mount enclosure PB/PC - PD - PL - PX FLOWMETER INPUT POWER SUPPLY BACKLIGHT 31 mm 29 mm (1.22") (1.14") 130 mm (5.12") 115 (4.53") 1 2 3 456 9 10 (4.72") P: coil PD: 16 - 30V DC ZB: 20 - 30V DC mm 120 + + + 98 (3.86") P: reed switch / NPN Sensor supply: For pulse input + (type P): 8.2V DC HB & HC enclosures panel cut-out P: active signal + Aluminum & GRP field / wall mount enclosures P: PNP 130 mm (5.12") Ø 7mm (0.27") Ø 7mm (0.27") - + P: namur - (4.72") A: (0)4 - 20mA mm For analog input (type A): voltage as (2.36") 120 I+ connected to terminal 5. mm 60 U: 0 - 10V 75 mm (2.95") 112 mm (4.40") For analog input (type U): voltage as U+ connected to terminal 5. Aluminum GRP A - PL: 4 - 20mA PL: input loop powered. 30mm 30mm mm I+ 22,50 HA HD PX: 8 - 30V DC PG9 M20 x 1,5 PG9 + 30mm 30mm 30mm 30mm PB / PC: battery powered mm mm (PX is also available: if an external supply is connected, the battery supply will be switched off / on automatically.) 22,50 22,50 HM HE M16 x 1,5 M20 x 1,5 M16 x 1,5 Ø16Ø20 Ø16 0.9") mm Terminal connections power supply PF - PM mm ( 22,50 HN HF 22,50 7 M20 x 1,5 Ø22 ( /8") 25mm 25mm 25mm 25mm mm POWER SUPPLY FLOWMETER INPUT mm 22,50 22,50 HO HG M20 x 1,5 M20 x 1,5 Ø20 Ø20 GND 1 2 34 5 6 7 12mm 12mm 12mm 12mm PF: 24V AC P: coil mm mm 17 17 mm HP HH mm 14 14 PF: 24V DC P: reed switch / NPN 24mm 24mm 6 x M12 24mm 24mm Ø12 36mm 36mm 36mm 36mm - + + 30mm (1.18") 30mm (1.18") 0.9") PM: 115 - 230V AC P: PNP mm ( 0.9" HT HJ - + 22,50 P: namur 1 7 7 7 /2"NPT Ø22 ( /8") Ø22 ( /8") Ø22 ( /8") - + 1.18" 1.18" P: active signal 0.9" HU HK + 1 /2"NPT 1 1 2 Flat bottom, no holes available. /2"NPT / "NPT A: (0)4 - 20mA 15mm 15mm + + mm 15 U: 0 - 10V mm HV + + 16 38mm 4 x M20 x 1.5 HZ F010 3 Typical wiring diagram F010-P-PB-(PX)-(ZB) Typical wiring diagram F010-A-PX-ZB Type PB: Type PX: TERMINAL CONNECTORS BATTERY POWERED TERMINAL CONNECTORS BASIC 8 - 30V DC POWER SUPPLY F0 - series F0 - series (STANDARD) Backlight option: type ZB Backlight supply 10 Backlight option: type ZB Backlight supply 10 20 - 30V DC 20 - 30V DC (not used in this example) Common ground 9 Common ground 9 + Power supply type PX: 5 5 Power supply type PX: Main supply 8 - 30V DC Main supply 8 - 30V DC 8 - 30V DC (not used in this example) Common ground 4 Common ground 4 - Supply * 3 Signal Flowmeter input Signal type P: type of signal pulse type of signal Circuit depends on Circuit depends on Flowmeter input type A: (0)4 - 20mA Common ground 12 Common ground 12 * Sensor supply voltage for pulse flowmeter type P: * Sensor supply voltage for pulse flowmeter type P: Terminal 3: 1.2 / 3.2V DC. Terminal 3: 1.2 / 3.2V DC. * Sensor supply voltage for analog flowmeter type A / U: * Sensor supply voltage for analog flowmeter type A / U: Terminal 3: not available. Terminal 3: not available. Typical wiring diagram F010-A-PL-ZB Typical wiring diagram F010-P-PD-ZB Type PL: Type PD: TERMINAL CONNECTORS INPUT LOOP POWERED TERMINAL CONNECTORS 16 - 30V DC POWER SUPPLY F0 - series F0 - series + Backlight option: type ZB 20 - 30V DC Backlight supply 10 Backlight option: type ZB 20 - 30V DC Backlight supply 10 Common ground 9 - Common ground 9 Supply * 6 + 5 Power supply type PD: Main supply 16 - 30V DC 16 - 30V DC Common ground 4 - Flowmeter input type A - PL: Supply * Input loop powered 4 - 20mA 3 Signal + Signal Flowmeter input type P: type of signal type of signal pulse 8 - 30V DC Circuit depends on Circuit depends on Common ground 12 - Common ground 12 Sensor supply: sensor is externally powered. * Sensor supply voltage for pulse flowmeter type P: Terminal 3: 1.2 / 3.2V DC. Terminal 6 with type PD: 8.2V DC. * Sensor supply voltage for analog flowmeter type A / U: Terminal 3: not available. Terminal 6 with type PD: voltage as connected to terminal 5 (internally linked). 4 F010 Typical wiring diagram F010-P-PF-ZB Typical wiring diagram F010-A-PF-ZB Type PF: Type PF: TERMINAL CONNECTORS 24V AC / DC POWER SUPPLY TERMINAL CONNECTORS 24V AC / DC POWER SUPPLY F0 - series F0 - series Backlight option: type ZB Backlight option: type ZB Internally powered. Internally powered. Supply * Supply * 7 7 Flowmeter input type A: Signal Flowmeter input Signal (0)4 - 20mA type P: type of signal pulse type of signal Circuit depends on Circuit depends on Common ground 56 Common ground 56 2 2 Main supply 24V AC Main supply + 1 1 Power supply type PF: Power supply type PF: 24V DC 8 - 24V AC / DC 8 - 24V AC / DC Common ground 0 Earth Common ground 0 - * Sensor supply voltage for pulse flowmeter type P: * Sensor supply voltage for pulse flowmeter type P: Terminal 7: 1.2 / 3.2 / 8.2 / 12 / 24V DC.