Phoenix Contact Automation Catalog
Total Page:16
File Type:pdf, Size:1020Kb
I/O systems in the IP65/67 field 342 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field More flexible – smaller – faster – better value Program overview Phoenix Contact is actively pursuing these trends with innovative I/O systems Fieldline Stand-Alone 345 for perfect solutions in field wiring and control cabinet construction. Fieldline Modular 361 Fieldline Stand-Alone Fieldline Extension AS-Interface 385 Fieldline Stand-Alone is optimally suitable for recording digital inputs and Rugged Line 401 outputs in harsh ambient conditions in machine and system engineering. Fieldline Stand-Alone is the compact design of the Fieldline I/O system. The combination of Manuals, data sheets, application notes and configuration files input/output modules makes a simple can be found in the download area at www.phoenixcontact.net/ connection of commonly used sensors and download. actuators possible. A Fieldline Stand-Alone IO-Link master has been added to the Fieldline Stand-Alone product range. Use of the IO-Link technology enables seamless You can find information regarding our product and solution-oriented communication from the controller services from page 11 onwards as well as in our online catalog to the sensor/actuator level. (www.phoenixcontact.net/eshop). Fieldline Modular Fieldline Modular offers a cost-effective and high-performance modular solution for complex I/O functions of field wiring. A Fieldline Modular IO-Link master is now available in the Fieldline Modular product range as well. Fieldline Extension AS-interface The AS interface devices of the Fieldline Extension product range are characterized by their ease of operation during mounting and handling. Rugged Line Thanks to their design, the Rugged Line devices enable high availability even in rough industrial environments, e.g. in the automobile industry. A PROFINET IO device has been added to the existing range of Rugged Line devices. Users thus have the future-oriented PROFINET technology at their disposal even in rough industrial environments. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 343 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field 344 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field | Fieldline Stand-Alone Fieldline Stand-Alone is the solution for the decentralization of small numbers Program overview of I/Os. Fieldline Stand-Alone can accommodate all commercially available Technical description 346 sensors and actuators in a standardized connection method. Product overview 348 The Fieldline Stand-Alone can be Fieldline Stand-Alone devices connected to the following fieldbus systems: INTERBUS M12 350 –INTERBUS PROFIBUS M12 352 –PROFIBUS – DeviceNetTM DeviceNetTM M12 354 –CANopen CANopen M12 356 Whether installed on profiles, level PROFIBUS IO-Link master 358 surfaces, or under difficult conditions, the Fieldline Stand-Alone mounting concept means flexibility of assembly, reduction in installation costs, and a robust installation that reduces machine downtime. The two mounting directions provided by Fieldline Stand-Alone devices meet the requirements of every application. Connectors are always positioned so that installation times are kept to a minimum even in difficult mounting conditions. The revolutionary SPEEDCON fast connection technology from Phoenix Contact is ideal for this. The classic M12 connections can continue to be used with full compatibility. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 345 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field Fieldline Stand-Alone – Technical description Fieldbus connection Flexible mounting All M12 connections of a Fieldline The Fieldline system is an I/O system Fieldline Stand-Alone devices can be Stand-Alone device have the SPEEDCON fast connection technology. The "Plug and suitable for all buses. Every Fieldline Stand- installed on an even mounting surface as Turn" method – similar to a bayonet lock – Alone device is an independent bus device. follows: The devices are available for the following reduces the connection time of M12 – Directly from the front connectors by over 90%. bus systems: or –INTERBUS – Directly from the side –PROFIBUS Precise diagnostics TM For direct mounting on the front on a – DeviceNet grounded mounting surface, the devices are The diagnostic indicators (green/red) –CANopen grounded using the upper mounting screw. indicate whether an error is present or not. For side mounting and for front In the event of an error, they indicate the The Fieldline Stand-Alone devices can error type and location. A Fieldline Stand- be easily integrated into these networks. mounting on an ungrounded mounting surface, the devices are grounded using Alone device is functioning perfectly if all cable lugs (2.8 mm) via the external indicators are green. Addressing grounding connection. For the allocation of device addresses, the Fieldline Stand-Alone devices have a rotary encoding switch to set the address and, if required, the transmission speed for the PROFIBUS-DP, DeviceNet™ and CANopen bus systems. The rotary encoding switch X10 is used to specify the tens, and the switch X1 is used to specify the units of the device ID (module ID). The rotary encoding switches can be accessed from outside and can be easily operated using a screwdriver. Simple handling Two housing versions for the Fieldline Stand-Alone devices are available for all bus systems. The digital input devices convince with their compact housing. The devices with a separate actuator supply are only extended by these connections. The slots of the Fieldline Stand-Alone devices are positioned such that every M12 connector on the device is easy to access The status indicators (yellow) indicate and mount. the signal status of the corresponding input/ output. If the yellow status indicators are on, this indicates the signal state "1" of the input/output signal. 346 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field Fieldline Stand-Alone – Technical description Fieldbus DO 8 DI 8 DIO 4/4 DIO 4/4 24 V DC UL US 24 V DC UA11UA12 24 V DC24 DC UA21UA22 24 V DC UA11UA12 Device power supply Sensor/actuator power supply IO-Link With INTERBUS and PROFIBUS-DP, The sensors are supplied from the The new standard in the lowermost field the logic voltage UL and the sensor voltage sensor voltage US. level is called IO-Link. With the PROFIBUS US are supplied via the ULS IN connection. The voltage supply UA to the actuators slave FLS PB M12 IOL 4 M12, Phoenix Both voltages are forwarded to the ULS is only necessary for the devices that have Contact provides a device that enables the OUT connection. digital outputs. use of the IO-Link technology with For DeviceNet™, the voltage U is The different functions of the PROFIBUS. L connections - supply for DO devices and The use of the IO-Link technology always transferred via the bus cable and supply and forwarding for DIO devices - are enables seamless communication from the supplied at the BUS IN connection via V+/V- and then forwarded via BUS OUT. due to the different number of outputs and controller to the sensor/actuator level. their nominal current. Two voltages are The use of the Fieldline IO-Link master for For CANopen, the voltage CAN UL is connected to each connection for supplying PROFIBUS can help significantly reduce always transferred via the bus cable and UA, e.g. the voltages UA11 and UA12 at UA1. downtimes and maintenance costs, since supplied at the BUS IN connection via Each of these supply voltages supplies a it enables the transfer of parameter, V+/V- and then forwarded via BUS OUT. group of outputs. The advantage of this diagnostics and service data in addition structure is that the outputs can be to process data. switched off in groups. The current carrying capacity of the M12 connectors is 4 A per contact. The outputs are protected against short circuits and overloads. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 347 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field Fieldline Stand-Alone – Product overview Digital input Digital input and output 8 channels 16 channels 4 / 4 channels 8/8 channels Type FLS IB M12 DI 8 M12 FLS IB M12 DI 16 M12 FLS IB M12 DIO 4/4 M12-2A FLS IB M12 DIO 8/8 M12 Order No. 2736013 2736314 2736026 2736385 8 digital inputs, 16 digital inputs, 4 digital inputs, 8 digital inputs, IP65/67 degree of protection IP65/67 degree of protection 4 digital outputs, 2 A, 8 digital outputs, 500 mA, IP65/67 degree of protection IP65/67 degree of protection Page 350 350 351 351 Type FLS PB M12 DI 8 M12 FLS PB M12 DI 16 M12 FLS PB M12 DIO 4/4 M12-2A FLS PB M12 DIO 8/8 M12 Order No. 2736123 2736220 2736107 2736372 8 digital inputs, 16 digital inputs, 4 digital inputs, 8 digital inputs, IP65/67 degree of protection IP65/67 degree of protection 4 digital outputs, 2 A, 8 digital outputs, 500 mA, IP65/67 degree of protection IP65/67 degree of protection Page 352 352 353 353 Type FLS DN M12 DI 8 M12 FLS DN M12 DI 16 M12 FLS DN M12 DIO 4/4 M12-2A FLS DN M12 DIO 8/8 M12 Order No.