Phoenix Contact Automation Catalog

Total Page:16

File Type:pdf, Size:1020Kb

Phoenix Contact Automation Catalog I/O systems in the IP65/67 field 342 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field More flexible – smaller – faster – better value Program overview Phoenix Contact is actively pursuing these trends with innovative I/O systems Fieldline Stand-Alone 345 for perfect solutions in field wiring and control cabinet construction. Fieldline Modular 361 Fieldline Stand-Alone Fieldline Extension AS-Interface 385 Fieldline Stand-Alone is optimally suitable for recording digital inputs and Rugged Line 401 outputs in harsh ambient conditions in machine and system engineering. Fieldline Stand-Alone is the compact design of the Fieldline I/O system. The combination of Manuals, data sheets, application notes and configuration files input/output modules makes a simple can be found in the download area at www.phoenixcontact.net/ connection of commonly used sensors and download. actuators possible. A Fieldline Stand-Alone IO-Link master has been added to the Fieldline Stand-Alone product range. Use of the IO-Link technology enables seamless You can find information regarding our product and solution-oriented communication from the controller services from page 11 onwards as well as in our online catalog to the sensor/actuator level. (www.phoenixcontact.net/eshop). Fieldline Modular Fieldline Modular offers a cost-effective and high-performance modular solution for complex I/O functions of field wiring. A Fieldline Modular IO-Link master is now available in the Fieldline Modular product range as well. Fieldline Extension AS-interface The AS interface devices of the Fieldline Extension product range are characterized by their ease of operation during mounting and handling. Rugged Line Thanks to their design, the Rugged Line devices enable high availability even in rough industrial environments, e.g. in the automobile industry. A PROFINET IO device has been added to the existing range of Rugged Line devices. Users thus have the future-oriented PROFINET technology at their disposal even in rough industrial environments. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 343 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field 344 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field | Fieldline Stand-Alone Fieldline Stand-Alone is the solution for the decentralization of small numbers Program overview of I/Os. Fieldline Stand-Alone can accommodate all commercially available Technical description 346 sensors and actuators in a standardized connection method. Product overview 348 The Fieldline Stand-Alone can be Fieldline Stand-Alone devices connected to the following fieldbus systems: INTERBUS M12 350 –INTERBUS PROFIBUS M12 352 –PROFIBUS – DeviceNetTM DeviceNetTM M12 354 –CANopen CANopen M12 356 Whether installed on profiles, level PROFIBUS IO-Link master 358 surfaces, or under difficult conditions, the Fieldline Stand-Alone mounting concept means flexibility of assembly, reduction in installation costs, and a robust installation that reduces machine downtime. The two mounting directions provided by Fieldline Stand-Alone devices meet the requirements of every application. Connectors are always positioned so that installation times are kept to a minimum even in difficult mounting conditions. The revolutionary SPEEDCON fast connection technology from Phoenix Contact is ideal for this. The classic M12 connections can continue to be used with full compatibility. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 345 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field Fieldline Stand-Alone – Technical description Fieldbus connection Flexible mounting All M12 connections of a Fieldline The Fieldline system is an I/O system Fieldline Stand-Alone devices can be Stand-Alone device have the SPEEDCON fast connection technology. The "Plug and suitable for all buses. Every Fieldline Stand- installed on an even mounting surface as Turn" method – similar to a bayonet lock – Alone device is an independent bus device. follows: The devices are available for the following reduces the connection time of M12 – Directly from the front connectors by over 90%. bus systems: or –INTERBUS – Directly from the side –PROFIBUS Precise diagnostics TM For direct mounting on the front on a – DeviceNet grounded mounting surface, the devices are The diagnostic indicators (green/red) –CANopen grounded using the upper mounting screw. indicate whether an error is present or not. For side mounting and for front In the event of an error, they indicate the The Fieldline Stand-Alone devices can error type and location. A Fieldline Stand- be easily integrated into these networks. mounting on an ungrounded mounting surface, the devices are grounded using Alone device is functioning perfectly if all cable lugs (2.8 mm) via the external indicators are green. Addressing grounding connection. For the allocation of device addresses, the Fieldline Stand-Alone devices have a rotary encoding switch to set the address and, if required, the transmission speed for the PROFIBUS-DP, DeviceNet™ and CANopen bus systems. The rotary encoding switch X10 is used to specify the tens, and the switch X1 is used to specify the units of the device ID (module ID). The rotary encoding switches can be accessed from outside and can be easily operated using a screwdriver. Simple handling Two housing versions for the Fieldline Stand-Alone devices are available for all bus systems. The digital input devices convince with their compact housing. The devices with a separate actuator supply are only extended by these connections. The slots of the Fieldline Stand-Alone devices are positioned such that every M12 connector on the device is easy to access The status indicators (yellow) indicate and mount. the signal status of the corresponding input/ output. If the yellow status indicators are on, this indicates the signal state "1" of the input/output signal. 346 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field Fieldline Stand-Alone – Technical description Fieldbus DO 8 DI 8 DIO 4/4 DIO 4/4 24 V DC UL US 24 V DC UA11UA12 24 V DC24 DC UA21UA22 24 V DC UA11UA12 Device power supply Sensor/actuator power supply IO-Link With INTERBUS and PROFIBUS-DP, The sensors are supplied from the The new standard in the lowermost field the logic voltage UL and the sensor voltage sensor voltage US. level is called IO-Link. With the PROFIBUS US are supplied via the ULS IN connection. The voltage supply UA to the actuators slave FLS PB M12 IOL 4 M12, Phoenix Both voltages are forwarded to the ULS is only necessary for the devices that have Contact provides a device that enables the OUT connection. digital outputs. use of the IO-Link technology with For DeviceNet™, the voltage U is The different functions of the PROFIBUS. L connections - supply for DO devices and The use of the IO-Link technology always transferred via the bus cable and supply and forwarding for DIO devices - are enables seamless communication from the supplied at the BUS IN connection via V+/V- and then forwarded via BUS OUT. due to the different number of outputs and controller to the sensor/actuator level. their nominal current. Two voltages are The use of the Fieldline IO-Link master for For CANopen, the voltage CAN UL is connected to each connection for supplying PROFIBUS can help significantly reduce always transferred via the bus cable and UA, e.g. the voltages UA11 and UA12 at UA1. downtimes and maintenance costs, since supplied at the BUS IN connection via Each of these supply voltages supplies a it enables the transfer of parameter, V+/V- and then forwarded via BUS OUT. group of outputs. The advantage of this diagnostics and service data in addition structure is that the outputs can be to process data. switched off in groups. The current carrying capacity of the M12 connectors is 4 A per contact. The outputs are protected against short circuits and overloads. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 PHOENIX CONTACT 347 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field Fieldline Stand-Alone – Product overview Digital input Digital input and output 8 channels 16 channels 4 / 4 channels 8/8 channels Type FLS IB M12 DI 8 M12 FLS IB M12 DI 16 M12 FLS IB M12 DIO 4/4 M12-2A FLS IB M12 DIO 8/8 M12 Order No. 2736013 2736314 2736026 2736385 8 digital inputs, 16 digital inputs, 4 digital inputs, 8 digital inputs, IP65/67 degree of protection IP65/67 degree of protection 4 digital outputs, 2 A, 8 digital outputs, 500 mA, IP65/67 degree of protection IP65/67 degree of protection Page 350 350 351 351 Type FLS PB M12 DI 8 M12 FLS PB M12 DI 16 M12 FLS PB M12 DIO 4/4 M12-2A FLS PB M12 DIO 8/8 M12 Order No. 2736123 2736220 2736107 2736372 8 digital inputs, 16 digital inputs, 4 digital inputs, 8 digital inputs, IP65/67 degree of protection IP65/67 degree of protection 4 digital outputs, 2 A, 8 digital outputs, 500 mA, IP65/67 degree of protection IP65/67 degree of protection Page 352 352 353 353 Type FLS DN M12 DI 8 M12 FLS DN M12 DI 16 M12 FLS DN M12 DIO 4/4 M12-2A FLS DN M12 DIO 8/8 M12 Order No.
Recommended publications
  • What's New from the OPC Foundation?
    Interoperability on the Next Level: OPC-Unified Architecture JAI2010 18.11.2010 – Vigo Stefan Hoppe President OPC Europe [email protected] Agenda • Introduction OPC Foundation • OPC UA details • Advantages of Combined Standards • Demo OPC Foundation • International Industry Standard Organization • OPC Foundation • 407+ Member Companies / 80+ end-users Members • OPC Portfolio • 3500 + Total Companies Build OPC Products = 22000 + Products • OPC UA details • Millions & Millions of OPC Installations • Cooperation • The vision of OPC is secure reliable multi-vendor multi-platform interoperability • for moving information vertically from the data sources through the enterprise of multi-vendor systems (with stops in between…) • For moving information horizontally between data sources on different industrial networks from different vendors; • Not just data but information……. • Reliable, Secure Interoperability is not an option • Collaboration is key to incorporating many multiple “open” standards into an unified open platform architecture World Membership Demographics • OPC Foundation OPC Members By Region • OPC Portfolio • OPC UA details Rest of World , • Cooperation 41 China , 5 China Europe North America Europe , 216 Japan , 142 North America Rest of World Japan , 36 OPC Board of Directors • Reinhold Achatz, Siemens • OPC Foundation • OPC Portfolio Reinhold has been on the OPC Board of Directors longer • OPC UA details than any other board member, he is the founding member for Siemens on the Board of Directors (1997) • Cooperation
    [Show full text]
  • SMART HOME SYSTEMS with the Contribution Of
    Branko Dvoršak Juraj Havelka Elena Mainardi Hrvoje Pandžić Tea Selič Mario Tretinjak SMART HOME SYSTEMS With the contribution of: Vanja Husein Claudia Pacchiega Goran Švast 2 This publication is part of the SHVET project (https://www.smart-hvet.eu/), and has been made possible with the contribution of (in alphabetical order): Center Republike Slovenije za poklicno Izobraževanje (Slovenia) Centoform (Italy) Ecipa Nordest (Italy) Območna Obrtno-Podjetniška zbornica Krško (Slovenia) Obrtničko učilište – ustanova za obrazovanje odraslih (Croatia) Šolski center Novo mesto (Slovenia) Sveučilište u Zagrebu Fakultet elektrotehnike i računarstva (Croatia) This project has been funded with support from the European Commission. This publication reflects the views only of the authors and the Commission cannot be held responsible for any use which may be made of the information contained therein. 3 TABLE OF CONTENTS page 1 INTRODUCTION 4 1.1 WHAT EXACTLY IS A "SMART HOUSE" 5 1.2 HOME AND BUILDING AUTOMATION 6 1.3 FUNCTIONS YOU CAN DO WITH A SMART HOME SYSTEM 6 2 DIFFERENCE BETWEEN A SMART HOME SYSTEM AND A STANDARD ELECTRIC PLANT 13 2.1 ELEMENTS OF A CLASSIC RESIDENTIAL INSTALLATION 13 2.2 STRUCTURE OF A SMART HOME SYSTEM 18 2.3 MODULES OF A SMART HOME SYSTEM 20 3 SMART HOME SYSTEM TECHNOLOGIES 26 3.1 OVERVIEW OF AUTOMATION AND CONTROL TECHNOLOGIES 25 3.2 WHY KONNEX 28 4 KONNEX 30 4.1 HISTORY OF KNX/EIB AND KONNEX ORGANIZATION 30 4.2 TRANSMISSION MEDIA 30 4.3 NET ARCHITECTURE 32 4.4 TOPOLOGY 35 4.5 ADDRESSES 36 4.6 TELEGRAM 38 4.7 PARAMETERIZATION
    [Show full text]
  • Deliverable Title
    Contract No. H2020 – 826098 CONTRIBUTING TO SHIFT2RAIL'S NEXT GENERATION OF HIGH CAPABLE AND SAFE TCMS. PHASE II. D1.1 – Specification of evolved Wireless TCMS Due date of deliverable: 31/12/2019 Actual submission date: 20/12/2019 Leader/Responsible of this Deliverable: Igor Lopez (CAF) Reviewed: Y Project funded from the European Union’s Horizon 2020 research and innovation programme Dissemination Level PU Public X CO Confidential, restricted under conditions set out in Model Grant Agreement Start date: 01/10/2018 Duration: 30 months CTA2-T1.1-D-CAF-005-09 Page 1 of 175 20/12/2019 Contract No. H2020 – 826098 Document status Revision Date Description First issue. Executive summary, Introduction and General 01 27/11/2018 architecture 02 27/06/2019 Contributions of sections 3.1, 3.2, 4.2, 5.2, 5.3, 6.1, 6.2, 6.3, 8 03 03/09/2019 Section 4.1 added. Updated sections 5, 6 and 8 Doc template: corrected footer Abbreviations and Acronyms list: updated Section 3.2: corrected internal references according to CTA2- 04 22/11/2019 T1.1-I-BTD-008-04 Sections 6: updated accoding to CTA2-T1.1-I-BTD-030-09, added new references, corrected internal references 05 05/12/2019 Section 4.2.3: content added 06 06/12/2019 Updated according to CTA2-T1.1-R-SNF-061-01 07 08/12/2019 Section 5.2 and 5.3 added. 08 17/12/2019 Reviews to new contributions applied Whole Document review from CTA2 T1.1 members, TMT and 09 20/12/2019 Safe4RAIL-2 members Disclaimer The information in this document is provided “as is”, and no guarantee or warranty is given that the information is fit for any particular purpose.
    [Show full text]
  • SEW Eurodrive MOVITRAC 31 INTERBUS Fieldbus Interface Manual
    T MOVITRAC® 31.. Frequency Inverters INTERBUS Fieldbus Interface (FFI31.. option and size 0/INTERBUS) Manual Edition 1/99 08/198/96 U U C ® L ® L 0922 6915/ 199 Important Notes Important Notes • Read this user manual carefully before you start installation and commissioning work on MOVITRAC® frequency inverters with fieldbus options. This user manual assumes that the user is familiar with and has at his disposal all relevant documentation on the MOVITRAC® system, particularly the installation and operating instructions. • Safety notes: Always follow the safety notes contained in this user manual. Safety notes are marked as follows: Electrical hazard, e.g. during live working Mechanical hazard, e.g. when working on hoists. Important instructions for the safe and fault-free operation of the system, e.g. pre- setting before commissioning.Failure to follow these instructions may result in injury to people and damage to property. • General safety notes for bus systems: The fieldbus option gives you a communications system which allows you to match the MOVITRAC® 31.. drive system to the specifics of your application to a very high degree. As with all bus systems there is, however, the risk of parameters being changed, which will not show outside (i.e. the inverter) but affect the behaviour of the inverter. This may result in unexpected (not uncontrolled, though) system behaviour. • In these instructions, cross-references are marked with an →, e.g., (→ MC_SHELL) means: Please refer to the MC_SHELL User Manual for detailed information or information on how to carry out this instruction. (→ section x.x) means: Further information can be found in section x.x of this user manual.
    [Show full text]
  • Fieldbus Couplers
    4 Fieldbus Couple rs 126 Housing Design I with System Powe r Supply Dimensions (mm) 51 x 65 x 100 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 2.5 mm² / 28 ... 14 AWG Strip lengths 8 ... 9 mm / 0.33 in. Housing Design II with System Powe r Supply Dimensions (mm) 62 x 65 x 100 W x H x L (Height from upper edge of the DIN-rail) Housing Design without System Powe r Supply Dimensions (mm) 50 x 65 x 97 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 1.5 mm² / 28 ... 14 AWG Strip lengths 5 ... 6 mm / 0.22 in. Housing Design ECO Dimensions (mm) 50 x 65 x 97 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 1.5 mm² / 28 ... 16 AWG Strip lengths 5 ... 6 mm / 0.22 in. Modula r I/O- System Ove rview 4 r Fieldbus Couple s 127 Housing Design without System with System Power Supply Power Supply ECO Fi eldbus System Desc ription Item No. Page Fieldbus Couple r, 100 Mbit 750-340 128 Fieldbus Couple r, 2-port, 100 Mbit 750-370 130 Fieldbus Couple r, advanced, 2-port 750-375 132 Fieldbus Couple r, advanced, 2-port, extended operating temperature range: -20 °C ... +60 °C 750-375/025-000 132 Fieldbus Couple r, advanced, ECO, 2-port 750-377 134 Fieldbus Couple r, advanced, ECO, 2-port, extended operating temperature range: -20 °C ..
    [Show full text]
  • Instruction Manual Universal Fieldbus-Gateway UNIGATE® IC- Interbus
    your ticket to all buses Instruction Manual Universal Fieldbus-Gateway UNIGATE® IC- Interbus Manual Art.-No.: V3317E Deutschmann Automation GmbH & Co. KG | Carl-Zeiss-Str. 8 | D-65520 Bad Camberg Tel:+49 6434 9433-0 | Hotline: +49 6434 9433-33 | Fax: +49 6434 9433-40 www.deutschmann.com Deutschmann Automation GmbH & Co. KG 1 General introduction . 9 2 The UNIGATE® IC . 10 2.1 Technical introduction . 10 2.2 Availability . 10 2.3 Firmware . 10 2.4 The serial standard interface . 10 2.5 The synchronous serial interface . 10 2.6 The Debug-interface . 10 2.7 UNIGATE® IC hardware survey . 11 3 Hardware design. 12 3.1 Ports . 12 3.2 Pinout . 12 3.2.1 -Boot enable . 13 3.2.2 Load out (SPI-Master: SS0-) . 13 3.2.3 Data out (SPI-Master: SS1-). 13 3.2.4 Data In (SPI: MISO) . 13 3.2.5 Load In (SPI: MOSI) . 13 3.2.6 Clock. 13 3.2.7 -Reset In . 14 3.2.8 LED RESREG-, RBDA, BA . 14 3.2.9 -Config Mode . 14 3.2.10 DbgTX, DbgRx. 14 3.2.11 TE . 14 3.2.12 TX, RX . 14 3.3 Software . 14 3.3.1 Basic line of proceeding . 15 3.4 Connection examples . 15 3.5 Layout examples . 18 3.6 Handling (mounting the UNIGATE® IC on the carrier board) . 20 4 The serial interface . 21 4.1 Overview . 21 4.2 Initialization of the serial interface . 21 4.3 Use of the serial interface . 21 4.4 Further operation modes .
    [Show full text]
  • INTERBUS System Technology Basics INTERBUS
    First steps with INTERBUS System Technology Basics INTERBUS INTERBUS - The Sensor/Actuator Bus A complete system overview with which you can quickly and easily www.stevenengineering.com find answers to your questions on the INTERBUS system. You will also get the know-how required for a first general decision on the 9200 - 8 fieldbus topic and especially on INTERBUS. Any questions, suggestions, help, etc. Send mail to: WebMaster [email protected] Outside Local Area: (800) 25 9200 - 8 Main Office: (650) 58 6370 - 230 Ryan Way, South San Francisco, CA, 94080 Courtesy of Steven Engineering, Inc. [Top] [Prev] [Next] [End] Contents 1. Preface to the INTERBUS Club 2. INTERBUS at the Center of Automation www.stevenengineering.com 2.1 Introduction 9200 - 2.2 INTERBUS and Standardization 8 3. INTERBUS Technology 3.0.1 Demands of Sensors/Actuators on a Bus System 3.0.2 A Comparison of Data Transmission Methods 3.0.3 INTERBUS, the Sensor/Actuator Bus 3.0.3.1 INTERBUS Topology Outside Local Area: (800) 25 3.0.4 The INTERBUS Transmission Protocol 9200 - 8 3.0.5 Technical Implementation of the Transmission Protocol 3.0.6 The User Interface 3.0.6.1 PMS Services 3.0.7 Practical Application of INTERBUS Main Office: (650) 58 3.0.8 Standardized Start up, Operation and Diagnostics with the INTERBUS Manager CMD 6370 - 3.0.9 INTERBUS Loop 3.0.10 Standardized Networking with INTERBUS 3.0.11 Device Interoperation with Profiles 3.0.12 INTERBUS Products and Manufacturers 3.1 Open Architecture in the PLC World using INTERBUS 3.2 Open Control 3.2.1 INTERBUS with PC-based Control Technology 4.
    [Show full text]
  • Specification in Brief Breakthrough on Communication
    IO-Link At a Glance Specification in Brief Breakthrough on communication IO-Link at a Glance Version 1.1 Date: Nov. 19, 2010 Prepared, approved, and released by IO-Link We welcome any comments, suggestions, and questions regarding this document. Please send these to www.io-link-projects.com and include your name and e-mail address. Important notes: NOTE 1 For every IO-Link device there is an associated IODD file. The file and any updates must be readily available at any time. The IO- Link manufacturer is responsible for ensuring that the IODD file has been tested using the IODD Checker and is available for download at www.io-link.com NOTE 2 For every IO-Link device the following documents are available for download from www.io-link.com: manufacturer's declaration of conformity to this specification, the released IODD, and test documents. Exclusion of liability: The information contained in this document is subject to change. The material presented in this document defines an IO-Link specification in accordance with the license and the explanatory notes contained on this page. This document is not a commitment that a company's products will implement all parts of this specification. Under no circumstances will we be liable for any errors contained herein or for indirect, incidental, special, or consequential damages, damages caused by relying on the information herein, or compensation for damages, including damages arising from lost profits, capital loss, or downtime, that are incurred by a user or by third parties. Compliance with this specification does not release the manufacturer of IO-Link devices from complying with the requirements of safety and regulatory authorities (TÜV, BIA, UL, CSA, etc.).
    [Show full text]
  • Abstraction of Wireless Communication by a Convergence Middleware in Conjunction with a Xml-Configuration
    07 - 10 September 2009 PROCEEDINGS 54. IWK Internationales Wissenschaftliches Kolloquium International Scientific Colloquium Information Technology and Electrical Engineering - Devices and Systems, Materials and Technologies for the Future Faculty of Electrical Engineering and Information Technology Startseite / Index: http://www.db-thueringen.de/servlets/DocumentServlet?id=14089 Impressum Herausgeber: Der Rektor der Technischen Universität llmenau Univ.-Prof. Dr. rer. nat. habil. Dr. h. c. Prof. h. c. Peter Scharff Redaktion: Referat Marketing Andrea Schneider Fakultät für Elektrotechnik und Informationstechnik Univ.-Prof. Dr.-Ing. Frank Berger Redaktionsschluss: 17. August 2009 Technische Realisierung (USB-Flash-Ausgabe): Institut für Medientechnik an der TU Ilmenau Dipl.-Ing. Christian Weigel Dipl.-Ing. Helge Drumm Technische Realisierung (Online-Ausgabe): Universitätsbibliothek Ilmenau Postfach 10 05 65 98684 Ilmenau Verlag: Verlag ISLE, Betriebsstätte des ISLE e.V. Werner-von-Siemens-Str. 16 98693 llmenau © Technische Universität llmenau (Thür.) 2009 Diese Publikationen und alle in ihr enthaltenen Beiträge und Abbildungen sind urheberrechtlich geschützt. ISBN (USB-Flash-Ausgabe): 978-3-938843-45-1 ISBN (Druckausgabe der Kurzfassungen): 978-3-938843-44-4 Startseite / Index: http://www.db-thueringen.de/servlets/DocumentServlet?id=14089 ABSTRACTION OF WIRELESS COMMUNICATION BY A CONVERGENCE MIDDLEWARE IN CONJUNCTION WITH A XML-CONFIGURATION Peter Buschkuehle Volker Schuermann Joerg F. Wollert Department of Electrical Engineering and Computer Science, Bochum University of Applied Sciences Bochum, 44801, Germany ABSTRACT not have any wear. Also the individual radio modules can be built in such a way that they can withstand the Today the meaning of wireless technologies demands. A further point is that there is no special constantly increases. That is not only of interest in the radio technology for the automation industry.
    [Show full text]
  • Communication Services and Architectures
    Communication Services and Architectures 35010500 12/2018 Communication Services and Architectures Reference Manual (Original Document) 12/2018 35010500.15 www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this document on any medium whatsoever without permission of Schneider Electric, given in writing. You also agree not to establish any hypertext links to this document or its content. Schneider Electric does not grant any right or license for the personal and noncommercial use of the document or its content, except for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components.
    [Show full text]
  • Interbus Interfaces and Field Distributors / Manuals / 2008-11
    Drive Technology \ Drive Automation \ System Integration \ Services Drive System for Decentralized Installation InterBus Interfaces, Field Distributors Edition 11/2008 Manual 16727215 / EN SEW-EURODRIVE – Driving the world Contents Contents 1 Valid Components............................................................................................... 6 2 General Information ............................................................................................ 7 2.1 How to use the operating instructions......................................................... 7 2.2 Structure of the safety notes ....................................................................... 7 2.3 Rights to claim under limited warranty ........................................................ 8 2.4 Exclusion of liability..................................................................................... 8 2.5 Copyright..................................................................................................... 8 3 Safety Notes ........................................................................................................ 9 3.1 General ....................................................................................................... 9 3.2 Target group ............................................................................................... 9 3.3 Designated use ........................................................................................... 9 3.4 Other applicable documentation ..............................................................
    [Show full text]
  • Overview of Building Automation Protocols
    Considerations and challenges when integrating systems to achieve smart(er) buildings Lance Rütimann / SupDet 2015 / 04 March 2015 Unrestricted © Siemens AG 2015 All rights reserved. Integrating systems is not new … The technological development has advanced the dimension of integrations, both in quantitative and qualitative terms: . relay contacts . parallel data . serial data Cumulating events on one central point had its weaknesses. Unrestricted © Siemens AG 2015 All rights reserved. 04 March 2015 SupDet 2015 2 … but it has become more complex. And we continue to learn. Numbers of Protocols A protocol is a defined set of rules and regulations that determine how data is . 20+ Building Automation protocols transmitted in telecommunications . 35+ Process Automation protocols and computer networking . 4 Industrial Control System protocols . 4 Power System automation Source: http://en.wikipedia.org/wiki/List_of_automation_protocols Source: http://www.drillingcontractor.org/from-islands-to-clouds-the-data-evolution-10675 Distributed systems = increased redundancy Unrestricted © Siemens AG 2015 All rights reserved. 04 March 2015 SupDet 2015 3 Overview of Building Automation protocols 1. 1-Wire 14.Modbus (RTU or ASCII or TCP) 2. BACnet 15.oBIX 3. C-Bus 16.ONVIF 4. CC-Link Industrial Networks 17.VSCP 5. DALI 18.xAP 6. DSI 19.X10 7. Dynet 20.Z-Wave 8. EnOcean 21.ZigBee 9. HDL-Bus 10.INSTEON 11.IP500 12.KNX (previously AHB/EIB) 13.LonTalk Unrestricted © Siemens AG 2015 All rights reserved. 04 March 2015 SupDet 2015 4 Overview of Process Automation Protocols 1. AS-i 14.FINS 27.PieP 2. BSAP 15.FOUNDATION 28.Profibus 3. CC 16.HART 29.PROFINET IO 4.
    [Show full text]